www.AdeptFluidyne.
com
Advanced instrumentation solutions
crafted with highest precision
Working Principle
The Transit Time Flowmeter utilises two transducers that With flow, sound will travel faster in the direction of flow
function as both ultrasonic transmitters and receivers. and slower against the flow. The liquid velocity (V) inside
The transducers are clamped on the outside of a closed the pipe can be related to the difference in time of flight
pipe or inserted in the pipeline by use of isolating ball valve (rt) through the following equation:
assembly at a specific distance from each other. Transit
Time Flowmeters measure the time it takes for an V = KxDxrt
ultrasonic signal transmitted from one sensor, to cross a where V : Liquid velocity
pipe and be received by a second sensor. Upstream and K : Constant
downstream time measurements are compared. With D : Distance between the two transducers
no flow, the transit time would be equal in both directions. rt : Difference in time of flight
UFM 6710 UFM 6720 UFM 6730
2
Ultrasonic Flowmeter Series 6700
Technical Specifications : Series 6700
Parameters UFM 6710 UFM 6720 UFM 6730
Transmitter
Power supply 24 V DC ±20% 3 AAA NiMH built-in battery 24 V DC ±20%
110 V AC ±15% (12 hours of operation) & 110 V AC ±15%
240 V AC ±15% 100-240 V AC for the charger 240 V AC ±15 %
Velocity ±12 m/sec. Bidirectional ±12 m/sec. Bidirectional ±12 m/sec. Bidirectional
Display 2 lines, 16 characters, 4 lines, 16 characters, 2 lines, 16 characters,
LCD with back light, flow rate, LCD with back light, flow rate, LCD with back light, flow rate,
velocity, totaliser velocity, totaliser velocity, totaliser
Units User configurable English/Metric User configurable English/Metric User configurable English/Metric
Totaliser FWD, NET, REV, BATCH FWD, NET, REV, BATCH FWD, NET, REV, BATCH
(Gallons, ft3, Barrels, lbs, m3 ) (Gallons, ft3, Barrels, lbs, m3 ) (Gallons, ft3, Barrels, lbs, m3 )
Output 4-20 mA DC Std.* RS 232 4-20 mA DC Std.*
Accuracy ±1% of reading @ rate >0.5 m/sec. ±1% of reading @ rate >0.5 m/sec. ±1% of reading @ rate >0.5 m/sec.
Repeatability 0.2% of Span 0.2% of Span 0.2% of Span
Dimensions 251x190x96 mm 204x90x30 mm 251x190x96 mm
Weight <2.5 kg <0.5 kg <2.5 kg
Security Keypad lockout, access code enabled Keypad lockout, access code enabled Keypad lockout, access code enabled
Transducer
0 0
Suited temp. - Std. -40 C to 120 C -400C to 1200C -400C to 1200C
0 0 0 0
Suited temp. - High -40 C to 250 C -40 C to 250 C -400C to 2500C
S Transducer 15-80 mm 15-80 mm >65 mm
Pipe size M Transducer 50-700 mm 50-700 mm (Note : Long sensors available
L Transducer 400-4570 mm 400-4570 mm on request for thick pipelines)
S Transducer 45x30x30 mm 45x30x30 mm
Dimensions M Transducer 60x45x45 mm 60x45x45 mm 186 mm with 20 mm bore size
L Transducer 80x70x55 mm 80x70x55 mm
S Transducer < 0.3 kg < 0.3 kg
Weight M Transducer < 0.5 kg < 0.5 kg < 1.5 kg
L Transducer < 1.0 kg < 1.0 kg
Cable length 6 m Std. Can be extended up to 300 m 6 m Std. Can be extended up to 25 m 6 m Std. Can be extended up to 300 m
Flexible belts SS belt according to pipe size SS belt according to pipe size NA
Portable case NA Size - 463x383x103 mm NA
* Please refer to order code for options.
3
Ordering Code : UFM 6710/6730
M1 - UFM 6710 Data Logging
M2 - UFM 6730 1 - Required (Pl. specify)
For UFM 6710 2 - Not required
Power supply Sensor (Standard)
P1 - 24 V DC S - Small 15 - 80 mm Sensor Cable
P2 - 110 AC M - Medium 50 - 700 mm 6 - 6 m (Std.)
P3 - 240 V AC L - Large 400 - 4570 mm 10 - 10 m
P4 - Solar powered OR M - Any other length (Pl. specify)
P5 - Any other (Pl. Specify) Sensor (High Temp.)
HS - Small 15 - 80 mm Communication Interface
View Software HM - Medium 50 - 700 mm G1 - Not required
Y - Required HL - Large 400 - 4570 mm G2 - GSM
(select communication interface)
N - Not required G3 - GPRS
G4 - HART
For UFM 6730
Sensor Output
R - Regular pipelines OP1 - 4 - 20 mA DC
E - Extended OP2 - Pulse
OP3 - Relay
OP4 - RS 232 (Modbus RTU)
OP5 - RS 485 (Modbus RTU)
OP6 - Combinations of above (Pl. specify)
Ordering Code : UFM 6720
Sensor (Standard) Output Data Logging Sensor Cable
S - Small 15 - 80 mm N - None 0 - Not required 6 - 6 m (Std.)
M - Medium 50 - 700 mm C - RS 232 1 - Required (Pl. specify) 10 - 10 m
L - Large 400 - 4570 mm M - Any other length (Pl. specify)
OR
Sensor (High Temp.)
HS - Small 15 - 80 mm
HM - Medium 50 - 700 mm
HL - Large 400 - 4570 mm
4
UFM 6740
Ultrasonic Water Meter
Benefits
This is a battery-powered, transit-time Long term stability and accuracy over a wide range of conditions
Flowmeter utilising advanced digital High reliability and minimum maintenance requirement
processing technology. The meter Maintenance-free meter where no external power sources are
contains no moving parts and does not available
require any external power. It also has
Communication port permits transfer of data from remote stations
advantages such as ultra-low power
to central system via GSM - GPRS Modem
consumption, high accuracy and
reliability. The meter is designed for easy Self-adjusting transducer receiving circuit continually adapts to
installation. It has the same conduit changing pipe diameters due to scaling or corrosion
length with industrial mechanical water Fast response to flow transits
meter, but can be used just as Available with AMR function
conveniently as a mechanical water Battery life - 5 years
meter. Unique housing design rated to IP 68
On-board self diagnostic function and fault indicator
Technical Specifications : UFM 6740 Ultrasonic Water Meter
Parameters Specifications
Technical characteristics Low power consumption, digital process technology with stable & permanant PiezoSeal sensor
Accuracy Better than ±1% of reading
Repeatability Better than 0.2% of span
Display Total flow, flow rate, velocity, working time & date, signal intensity, quality & battery status
Output RS 485,4-20 mA, Pulse for total flow (All outputs need external power supply 24 V DC)
Communication interface GSM, GPRS (Can be battery powered)
Operation Magnetic key & inside key pad available
Sampling period 0.5 sec.
Environment temp. Up to 650C
Water temp. 5 to 700C
Power supply 3.6 V Lithium battery (Up to 5 years life)
Enclosure class IP 68
Pipe size DN 20-600
Flange connection DIN, ANSI 150, BS
5
Ordering Code : UFM 6740
Transmitter Type Line Size Design of Measuring Sensor
I - Integral 0020 - 20 (¾”) M1 - Flange DIN
R - Remote 0025 - 25 (1”) M2 - Flange ANSI 150
0032 - 32 (1.25”) M3 - Flange IS 1538
0040 - 40 (1.50”) M4 - Flange BS 10 Table D/E
0050 - 50 (2”) M5 - Any other (Pl. specify)
0065 - 65 (2.5”)
0080 - 80 (3”) Measuring Tube
0100 - 100 (4”) T1 - CS / MS
View Software
0125 - 125 (5”) T2 - SS 304
Y - Required
(select communication interface) 0150 - 150 (6”) T3 - SS 316
N - Not required
0200 - 200 (8”)
Flange Material
0250 - 250 (10”)
F1 - CS / MS
0300 - 300 (12”)
F2 - SS 304
0350 - 350 (14”)
F3 - SS 316
0400 - 400 (16”)
F4 - Any Other
0500 - 500 (20”) (Pl. specify)
0600 - 600 (24”) Communication Interface
C1 - Not required Protection Class
Output* for Sensor
C2 - GSM A - IP 65
OP1 - 4 - 20 mA DC
C3 - GPRS B - IP 68
OP2 - 0 - 20 mA DC
OP3 - Pulse output
OP4 - RS 232 (Modbus RTU)
OP5 - RS 485 (Modbus RTU)
(* All above outputs need
external 24 V DC supply)
Services for you
Calibration Rent a Flowmeter
We provide Flowmeter Calibration Facility at our works. Adept has a ready range of Ultrasonic Flowmeters
The facility uses the primary method of measuring the available for rent for any line size. All rentals are calibrated,
water flow by gravimetric principle or comparison quality checked and backed by our experienced
method. The facility is designed for calibration of manpower. With experience of more than 15 years, we
Flowmeters under controlled and stable flow conditions. will help you in calibrating your line flow for any liquid.
The lab is as per ISO 4185. It has a capacity from 10 mm
up to 450 mm.
NABL accreditation is awaited.
6
Sales and Service Network
Delhi
Jaipur
Ahmedabad Bhopal
Kolkata
Mumbai
«Pune
Hyderabad
« Corporate Office & Plant
Regional Office
Dealer
Bangalore Chennai
Technical changes reserved
Adept Series 6700 / 0115 / SK / kaleidoscopeB2B.com
Adept Fluidyne Pvt. Ltd.
Corporate Office & Plant :
Plot 4, S No. 17/1-B, Kothrud Ind. Estate,
Kothrud, Pune 411 038 INDIA
T +91 20 2546 4551/2543 1474
E info@adeptfluidyne.com
L
www.AdeptFluidyne.com