37-102
Five Conductor Power Cable
Gexol® Insulated Oil & Gas Cables
Extremely Flexible • 0.6/1kV • Rated 110°C
Conductors
Soft annealed flexible Application
stranded tinned copper Designed and constructed for the demanding
per IEEE 1580 Table 11. Insulation
GEXOL cross-linked
® environments of offshore drilling and petroleum
flame retardant polyolefin, facilities located throughout the world.
meeting the requirements
for Type P of IEEE 1580 Features
Jacket
and Type X110 of 䡲 High strand count conductors make this
UL 1309/CSA 245. product much more flexible, easier to install
A black, arctic grade,
Color code:
flame retardant, oil,
Black-White-Red-
and more resistant to vibration than Type MC,
abrasion, chemical
Green-Orange IEC spec or commercial cables.
and sunlight resistant
thermosetting 䡲 Gexol’s lower dielectric constant and higher
compound meeting insulation resistance reduces electrical losses.
UL 1309/CSA 245
and IEEE 1580. 䡲 Gexol’s excellent resistance to moisture
produces stable electrical properties
throughout the life of the cable.
Armor (Optional)
Basket weave wire 䡲 In a fire condition, Gexol’s nonchlorinated
armor per IEEE 1580 flame retardant system produces less toxic
and UL 1309/CSA 245. Sheath (Optional)
and less corrosive gases.
Bronze standard. A black, arctic grade,
Aluminum or tinned flame retardant, oil, 䡲 Dual certified IEEE 1580 Type P and
copper available abrasion, chemical UL 1309/CSA 245 Type X110.
by request. and sunlight resistant
thermosetting compound 䡲 Highest ampacity ratings: ABS 100˚C, DNV
meeting UL 1309/CSA 95˚C, LRS 95˚C, Transport Canada 95˚C.
245 and IEEE 1580.
䡲 Severe cold durability: exceeds CSA cold
bend/cold impact (-40˚C/-35˚C).
Ratings & Approvals 䡲 Flame retardant: IEC 332-3 Category A
䡲 110˚C Temperature Rating and IEEE 1202.
䡲 American Bureau of Shipping (ABS) 䡲 Suitable for use in Class 1 Division 1, and
99-BT5905-X Zone 1 environments (armored and sheathed).
䡲 Transport Canada 8700-20-2 䡲 Optional braid armor of bronze, aluminum
䡲 Det Norske Veritas (DNV) or tinned copper.
E-6669, E-6388, E-6390, E-6391
䡲 Lloyd’s Register of Shipping (LRS) Hawke
Gland Types Unarmored Armored & Sheathed
91/60333 (E6)
Industrial &
䡲 NVE 95/1696, FAL Safe Area (IP68) 121 153-X
䡲 UL Listed as Marine Shipboard Cable Increased Safety
“EExe” 501/421 501/453/U
(E111461)
Explosion Proof 710 753
䡲 United States Coast Guard Class 1 Div. 2 Class 1 Div. 1
November 2, 1987 / 9304 Class 1, Zone 2 Class 1, Zone 1 & 2
Other certifications pending Flameproof 501/421 501/453/U
“EExd” Zone 1 & 2 (2 liter or < enclosures)
ICG 653/U
(2 liter or > enclosures)
Zone 1 & 2
v1.06.1 www. amercable.com • e-mail: marine@amercable.com
37-102
Five Conductor Power Cable
Oil & Gas Cables Gexol® Insulated
Extremely Flexible • 0.6/1kV • Rated 110°C
Flexible Power Cable – Five Conductor
Armored and
Unarmored Armored (B) Sheath (BS)
Size Nominal Nominal Nominal AC Resistance Inductive Voltage Drop
AWG/ Part No. Diameter Weight Diameter Weight Diameter Weight DC Resistance at 110°C, 60 Hz Reactance 110°C Ampacity
kcmil mm2 37-102 (inches) (lbs/MFt.) (inches) (lbs/MFt.) (inches) (lbs/MFt.) 25°C (Ohms/1000 ft.) (Ohms/1000 ft.) (Ohms /1000 ft.) (Volts/Amp/1000 ft.) 110°C 100°C 95°C
18 1.0 -558 0.431 100 0.481 171 0.612 221 7.350 9.763 0.044 13.558 11 10 11
16 1.3 -559 0.456 110 0.506 189 0.639 264 4.610 6.121 0.042 8.514 14 13 13
14 2.1 -510 0.498 149 0.548 234 0.679 301 2.907 3.859 0.039 5.382 21 20 18
12 3.3 -560 0.550 196 0.600 266 0.744 334 1.826 2.424 0.037 3.393 27 25 22
10 5.2 -561 0.604 296 0.654 406 0.785 494 1.153 1.530 0.035 2.154 35 33 29
8 7.6 -562 0.765 453 0.815 569 0.988 704 0.708 0.940 0.037 1.339 45 42 38
6 12.5 -563 0.914 653 0.964 813 1.137 973 0.445 0.590 0.035 0.853 60 56 51
4 21 -565 1.137 1073 1.187 1292 1.360 1481 0.300 0.399 0.032 0.585 79 74 68
2 34 -566 1.315 1361 1.365 1637 1.538 1856 0.184 0.244 0.030 0.369 105 98 90
1 43 -567 1.470 2130 1.520 2192 1.756 2482 0.147 0.195 0.031 0.302 122 114 105
1/0 54 -568 1.618 2550 1.668 2746 1.903 3108 0.117 0.156 0.030 0.248 140 131 122
2/0 70 -569 1.802 2954 1.852 3301 2.088 3734 0.093 0.125 0.030 0.203 161 150 140
4/0 109 -746 2.167 3615 2.217 3955 2.453 4592 0.058 0.080 0.029 0.140 216 202 188
Cable diameters shown as nominal are subject to a ± 5% manufacturing tolerance
Ordering Gexol Oil & Gas Cables 37–102 – 566 BS
Example:
• 5 conductor power cable AmerCable Gexol Specific Cable Number Armor Requirement
• 0.6/1kV Oil & Gas Prefix (from charts) BS – armored &
• #2 AWG sheathed
• bronze armored & sheathed Blank – no armor
GEXOL® is a registered trademark of
AmerCable Incorporated
Manufactured by AmerCable Incorporated • 800-506-9473 • 713-896-5800 • Fax: 713-849-9009
10633 West Little York • Bldg. #1 • Suite #100 • Houston, TX 77041 • www. amercable.com
v1.06.1