Power Meter: Measurement Monitoring Analysis Communication

The T3 30 Power Meter by Taik Electric offers user-friendly, cost-effective solutions for energy measurement and monitoring with quick installation and setup. It features true RMS measurement, dual energy measurement, and supports various communication protocols including Modbus RS485. The device is certified CE and has a wide range of specifications for accuracy and performance across different electrical parameters.

Uploaded by

Joseph Ting
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
45 views4 pages

Power Meter: Measurement Monitoring Analysis Communication

The T3 30 Power Meter by Taik Electric offers user-friendly, cost-effective solutions for energy measurement and monitoring with quick installation and setup. It features true RMS measurement, dual energy measurement, and supports various communication protocols including Modbus RS485. The device is certified CE and has a wide range of specifications for accuracy and performance across different electrical parameters.

Uploaded by

Joseph Ting
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

T3 30 Po w e r Me te r

Measurement Monitoring Analysis Communication

TA IK ELECTRI C
Met er ing S o l u ti o n s
Power Meter

Benefits
User-friendly
Cost-effective
Quick installation
Light and short depth
Quick setup parameters
Energy-saved protection mode

Features
True RMS measurement
Dual energy measurement
Installation without using mounting clips
THD measurement up to 31st harmonics
Measurement in 1P/3P3W/3P4W systems
Actual demand/max. demand in watt & current
Modbus RS485 communication or pulse output
ON Hour indication as the auxiliary supply being powered on

Option
G (generator) sensing signal at digital input (status detect)
G (generator) sensing signal at (18-60V DC/ 80-300V AC)
Dual energy measurement in utility register & generator register

Certification
CE
TA I K E L ECT RI C
M e t e r i n g So l u ti o n s

Specifications: Input Voltage


Measured Parameters and Accuracy: Voltage range (line to line) AC 3 ~ 500V
Display Accuracy Voltage range (line to neutral) AC 2 ~ 288V
SYS L1 L2 L3
L-L volt 0.2% Maximum overload AC 750V
L-N volt 0.2% Input impedance 800KΩ
Current 0.2% Input burden 0.1VA
Active power 0.5%
Reactive power 0.5%
Apparent power 0.5%
Input Current
Power factor 0.5% Current range AC 5A (Standard) or 1A (Option)
Frequency 0.05Hz Input burden 0.1VA
Import (KWH) IEC62053-22 Class 0.5S Isolation Each phase, AC 600V
Ind(KVarH) IEC62053-23 Class 2 Starting current 0.2 % F.S.
Export (KWH) IEC62053-22 Class 0.5S
Cap (KVarH) IEC62053-23 Class 2
THD 2%
Demand 0.5% Power Supply
* Average Value Accuracy F.S.% Auxiliary power supply AC/DC 85-265V
DC 20-60V (Option)
Power consumption 4.5VA (Without RS 485)
5VA (With RS 485)
Characteristics Frequency range 45 ~ 65HZ

Dielectric strength IEC 60688, AC 2.3KV 1 min.


between input/output/power
AC 3KV 1 min. between all terminals/case
Display Screen
Operating temperature 0 ~ 60 Format LCD white backlit
Storage temperature -10 ~ 70 Character height 3 rows of 4 digits, 0.5’’, 13.0mm
Temperature coefficient 100PPM/
Max. humidity 95%
IP Enclosure IP 50 (Front plate)
IP 20 (Rear side) Set-up/Memorized Value
Sampling time 1 sec.
Measurements 1ψ2W, 1ψ3W, 3ψ3W, 3ψ4W Memory method FRAM
Actual demand Amp, Watt Memory period At least 20 years
Max.demand Amp, Watt
Demand time of period 1 ~ 60 min.(programmable)
Total harmonic distortion up to 31 st
Communication
Harmonic analysis Volt, Amp Interface RS 485
Protocol MODBUS, RTU
Baud rate 1200 ~ 38400 programmable
Address 1 ~ 255 programmable
Measurement Accuracy Data format N.8.1, N.8.2, O.8.1, E.8.1
Parallel connection Up to 32 meters
Current 0.2 %
Voltage 0.2 %
Active power 0.5 % Electromagnetic compatibility (EMC)
Reactive power 0.5 %
Apparent power 0.5 % Electrostatic discharge IEC 61000-4-2
Power factor 0.5 % Electromagnetic field immunity IEC 61000-4-3
Frequency 0.05Hz
Electrical fast transient/burst immunity IEC 61000-4-4
Active energy (Import/Export) (IEC 62053-22, class 0.5S)
Reactive energy (Ind/Cap) (IEC 62053-23, class 2) Surge immunity IEC 61000-4-5
Harmonics 2% Immunity to conducted disturbances IEC 61000-4-6
Demand (W,A) 0.5% Power frequency magnetic field immunity IEC 61000-4-8
Short interruptions and voltage variations immunity IEC 61 0 0 0 -4-11
Harmonic current emissions IEC 61000-3-2
Voltage changes, voltage fluctuations and flicker IEC 61000-3-3
Accuracy Performance Range
Current range 0.2 ~ 120 % Standards
Voltage range 0.6 ~ 120 %
Power & energy Amp. 0.2 ~ 120%, Volt. 0.6 ~ 120 % EN 61326-1 EN 55011 IEC 61000-4-3 IEC 6 1 0 0 0 - 4 - 6
Power factor range cosθ (sinθ) 0.5 ~ 1 EN 61326-2 IEC 60529 IEC 61000-4-4 IEC 6 1 0 0 0 - 4 - 8
Frequency range 45 ~ 65 Hz
Distortion level (THD) from 10% to 120% (Volt) EN 61000-3-2 IEC 62053-22 IEC 61000-4-5 IEC 61 0 0 0 -4-11
from 1% to 120% (Amp) EN 61000-3-3 IEC 61000-4-2

Measurement Monitoring Analysis Communication


CONNECTIONS

3 Phase 4 Wire(3 PTs, 3 CTs) 3 Phase 3 Wire(2 PTs, 3 CTs) 1 Phase 3 Wire(Only 2 CTs)

Aux. Source Aux. Source Aux. Source

3 Phase 4 Wire(Only 3 CTs) 3 Phase 3 Wire(2 PTs, 2 CTs) 1 Phase 2 Wire(Only 1 CT)

Aux. Source Aux. Source Aux. Source

DIMENSIONS (Unit: mm)


PANEL CUT-OUT

+0.5
91
-0.0

96 96

+0.5
91
-0.0

96 5.5 31 14.2

50.7

TAIK ELECTRIC CO., LTD.


4 T H F L . , N O . 5 , AL L EY 1 1 , L ANE 3 2 7 , CHUNGS H A N R D .,
SEC. 2, CHUNGHE DISTRICT, NEW TAIPEI CITY, TAIWAN, R.O.C.
TEL:(02)2242-6825 http://www.taik.com.tw
FAX:(02)2242-6827 E-mail: taikco@ms15.hinet.net
FM 40649