Novostrictive Transducer Up To 4250 MM Touchless: Series TH1
Novostrictive Transducer Up To 4250 MM Touchless: Series TH1
Transducer
up to 4250 mm
touchless
Series TH1
Applications
• Fluid Power
Pneumatic- or Hydraulic Cylinder
• Manufacturing Engineering
• Mobile Machinery
Page 1
Contents
Mechanical Data 3
Analog Versions
Technical Data 4
Ordering Specifications 5
Digital Versions
SSI 6
Impulse 7
Ordering Specifications 8
Fieldbus, IO-Link Versions
CANopen 9
IO-Link 10
Ordering Specifications 11
Accessories
Position marker 12
Fastening elements 13
M12 Connector System 14
M16 Connector System 17
Description
Materials Housing: Anodized aluminum, AlMgSi0,5 F22, 3.3206.71
Screw flange: stainless steel X2CrNiMoN 18-14-3, 1.3952
Rod: stainless steel X6CrNiMoTi 17-12-2, 1.4571
Mounting Bushing M18x1,.5 for screw plug hole per ISO6149
Bushing 3/4“-16UNF for screw plug hole per SAE J475
Position marker Ring shaped position marker
Messverfahren NOVOSTRICTIVE, touchless magnetostrictive
Electr. connections Connector M12x1, 4-pol., 5-pol. / 8-pin., shielded
Connector M16x0.75 (IEC 130-9), 6-pin. / 8-pon., shielded
PUR-cable, 8x0.25 mm2, shielded; 1 m, 3 m oder 5 m length
Electronic SMD with ASIC, integrated
Connector casing (shield) is connected to the sensor housing.
Housing is capacitively decoupled to the electronics
Mechanical Data
Dimensions see dimension drawing
Electrical measuring range 0050 up to 4250 mm in 25 mm steps
(Dimension L) other lengths on request
Max. operational speed 10 ms-1
with valid ouput signal
Max. operational acceleration 200 ms-2
with valid ouput signal
Shock (IEC 60068-2-27) 100 (11 ms) (single hit) g
Vibration (IEC 60068-2-6) 20 (5...2000 Hz, Amax = 0.75 mm) g
Protection class IP67 with fastened connector
(DIN EN 60529) IP68 with cable connection
Life Mechanically unlimited
Operating temperature range -40 ... +85 °C
Storage temperature range -40 ... +100 °C
Operating humidity range 0 ... 95 (no condensation) % R.H.
Pressure rating
Operating pressure < 350 bar
Pressure peaks < 600 bar
Burst pressure > 700 bar
Pin assignment
Connector Cable Connector Analog Analog Connector Connector Analog Analog
code 101, 102 code 20_ with cable voltage current code 103 with cable Voltage Current
(Accessories) (Accessories)
Pin 1 YE WH do not connect 0(4)...20 mA Pin 1 WH 0 ...+10 V 0 (4)...20 mA
Pin 2 GY BN Signal GND Signal GND Pin 2 BN Signal GND Signal GND
Pin 3 PK GN +10...0 V do not connect Pin 3 BU +10...0 V do not connect
Pin 4 RD YE DIAG * DIAG * Pin 4 BK GND GND
Pin 5 GN GY 0...+10 V do not connect Pin 5 GY Supply voltage Supply voltage
Pin 6 BU PK GND GND Pin 6 GN GND GND
Pin 7 BN BU Supply voltage Supply voltage
Pin 8 WH RD PROG * PROG *
*) Connect only for Teach-In-function (see manual).
Electrical connection
101: Connector M16x0.75 (IEC 130-9), 8-pin
102: Connector M12x1, 8-pin
103: Connector M16x0.75 (IEC 130-9), 6-pin
201: Cable, 8-pol., shielded, 1 m
203: Cable, 8-pol., shielded, 3 m
205: Cable, 8-pol., shielded, 5 m
Other cable lengths and assembled connectors on request
T H 1 – 0 8 0 0 – 1 0 2 – 4 1 1 – 1 0 2
*) with internal thread M4x6 at rod end and additional length 7.5 mm
Important: Avoid equalizing currents in the cable shield caused by potential differences.
Twisted pair cable (STP) is recommended.
Pin assignment
Connector Cable Connector SSI Connector Connector Connector SSI
code 101, 102 code 20 _ with cable Interface code 103 with cable code 108 Interface
(Accessories) (Accessories)
Pin 1 YE WH Clk + Pin 1 WH Pin 1 Data -
Pin 2 GY BN Data + Pin 2 BN Pin 2 Data +
Pin 3 PK GN Clk - Pin 3 BU Pin 3 Clk +
Pin 4 RD YE do not connect Pin 4 BK Pin 4 Clk -
Pin 5 GN GY Data - Pin 5 GY Pin 5 Supply voltage
Pin 6 BU PK GND Pin 6 GN Pin 6 GND
Pin 7 BN BU Supply voltage - - Pin 7 do not connect
Pin 8 WH RD do not connect
Pin assignment
Connector Cable Connector Start/Stop-Impulse Connector Connector Start/Stop-Impulse
code 101, 102 code 20 _ with cable Interface code 103 with cable Interface
(Accessories) (Accessories)
PIN 1 YE WH INIT + Pin 1 WH Start/Stop -
PIN 2 GY BN Start/Stop + Pin 2 BN Start/Stop +
PIN 3 PK GN INIT - Pin 3 BU INIT +
PIN 4 RD YE do not connect Pin 4 BK INIT -
PIN 5 GN GY Start/Stop - Pin 5 GY Supply voltage
PIN 6 BU PK GND Pin 6 GN GND
PIN 7 BN BU Supply voltage
PIN 8 WH RD do not connect
SSI-Interface 2 _ _
1: Binary code; resolution 5 μm
2: Gray code; resolution 5 μm
4: Binary code; resolution 1 μm
5: Gray code; resolution 1 μm
7: Binary code; resolution 10 µm
8: Gray code; resolution 10 μm
Electrical connection
101: Connector M16x0,75 (IEC 130-9), 8-pin
102: Connector M12x1, 8-pin
103: Connector M16x0.75 (IEC 130-9), 6-pin
108: Connector M16x0.75 (IEC 130-9), 7-pin (only SSI-Interface)
201: Cable, 8-pol., shielded, 1 m
203: Cable, 8-pol., shielded, 3 m
205: Cable, 8-pol., shielded, 5 m
Other cable lengths and assembled connectors on request
T H 1 – 0 8 0 0 – 1 0 2 – 2 1 1 – 1 0 2
*) with internal thread M4x6 at rod end and additional length 7.5 mm
Important: Avoid equalizing currents in the cable shield caused by potential differences.
Twisted pair cable (STP) is recommended.
Pin assignment
- Pin 4 n/a
Pin assignment
PIN 4 BK C/Q
*) alternatively on GND
T H 1 – 0 8 0 0 – 1 0 2 – 6 1 3 – 1 0 6
*) with internal thread M4x6 at rod end and additional length 7.5 mm
Important: Avoid equalizing currents in the cable shield caused by potential differences.
Only CANopen: Twisted pair cable (STP) is recommended.
Material PA6-GF25
Weight approx. 12 g
Weight approx. 14 g
4,3
32
24
20
36,4
12
Weight approx. 5g
13,5
Material 1.4404
Weight approx. 20 g
Material 1.4571
Weight approx. 42 g
Connector PUR
housing
© 07/2020
Printed in Germany.
Connector CuZn
housing (Brass, nickel plated)
-40 °C... +85 °C
Connector CuZn
housing (Brass, nickel plated)
-40 °C... +95 °C
CAN-bus UL - approved
The specifications contained in our datasheets are intended solely for informational purposes. The documented specification values are based on ideal operational and environmental conditions and
can vary significantly depending on the actual customer application. Using our products at or close to one or more of the specified performance ranges can lead to limitations regarding other per-
formance parameters. It is therefore necessary that the end user verifies relevant performance parameters in the intended application. We reserve the right to change product specifications without
notice.