0% found this document useful (0 votes)
18 views7 pages

Ac 2500-6

The document provides detailed specifications for Aksa's power generation systems, including standby and prime power ratings, engine and alternator characteristics, and control panel features. It outlines the technical specifications for the AC 2500-6 model, including dimensions, fuel consumption, and optional equipment. Additionally, it emphasizes the manufacturer's right to change specifications without prior notice.

Uploaded by

melami1990
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
18 views7 pages

Ac 2500-6

The document provides detailed specifications for Aksa's power generation systems, including standby and prime power ratings, engine and alternator characteristics, and control panel features. It outlines the technical specifications for the AC 2500-6 model, including dimensions, fuel consumption, and optional equipment. Additionally, it emphasizes the manufacturer's right to change specifications without prior notice.

Uploaded by

melami1990
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

INTRODUCTION

Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and
continuous duty applications. All generator sets are factory build, and production tested.

Power (kVA) 3 Phase,60 Hz, PF 0.8


STANDBY RATING (ESP) PRIME RATING (PRP)
VOLTAGE Standby Amper
kW kVA kW kVA

380/220 1812,00 2265,00 1647,00 2058,75 3441,41

480/277 2000,00 2500,00 1815,00 2268,75

STANDBY RATING (ESP) Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility
source. ESP is in accordance with ISO 8528-1. Overload is not allowed.

PRIME RATING (PRP) Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 %
overload capability is available for a period of 1 hour within 12-hour perod of operation.

General Characteristics
Model Name AC 2500-6
Frequency (Hz) 60
Fuel Type Diesel
Engine Made and Model CUMMINS QSK 60-G6 - 60Hz
Alternator Made and Model PI 734 F - 60Hz
Control Panel Model DSE 7320
Canopy AK 99 - External Removable Silencer

ENGINE SPECIFICATIONS
Engine CUMMINS
Engine Model QSK 60-G6 - 60Hz
Number of Cylinder (L) 16 cylinders - V type
Bore (mm.) 159
Stroke (mm.) 190
Displacement (lt.) 60.2
Aspiration Turbo Charged and One Pump Two Loop

Manufacturer reserves the right to make change in the model, technical specifications, color, equipment, accessories and images without prior notice. (05.12.2019)
Compression Ratio 14.5:1
RPM (d/dk) 1800
Oil Capacity (Total With Filter) (lt) 280
Standby Power (kW/HP) 2180/2922
Fuel Type Diesel
Type of Fuel Pump Cummins PT
Governor System Electronic
Operating Voltage (Vdc) 24 Vdc
Cooling Method Water Cooled
Coolant Capacity (engine only / with radiator) (lt) 682
Air Filter Dry Type
Fuel Cons. Prime With %100 Load (lt/hr) 471
Fuel Cons. Prime With %75 Load (lt/hr) 360
Fuel Cons. Prime With %50 Load (lt/hr) 254

ALTERNATOR CHARACTERISTICS
Manufacturer Stamford
Alternator Made and Model PI 734 F - 60Hz
Frequency (Hz) 60
Power (kVA) 1646,6
VOLTAGE (V) 380
Phase 3
A.V.R. MX341
Voltage Regulation (+/-)1%
Insulation System H
Rated Power Factor 0.8
WEIGHT COMP. GENERATOR (Kg) 3840

Open Gen.Set Dimensions (mm)


LENGTH 5710
WIDTH 2280
HEIGHT 3220
DRY WEIGHT (kg.) 15500
TANK CAPACITY (lt.) 2000

Gen.Set Canopy Dimensions (mm)


LENGTH 9000
WIDTH 2800
HEIGHT 3300
DRY WEIGHT (kg.) TBD
TANK CAPACITY (lt.) 2200
1. Steel structure made from steel sheet and steel

Manufacturer reserves the right to make change in the model, technical specifications, color, equipment, accessories and images without prior notice. (05.12.2019)
profiles.
2. Canopy and panels made from powder coated sheet
steel.
3. Emergency stop push button.
4. Control panel is mounted on the baseframe located at
the back of the Generator set.
5. Cables out locations are back of the canopy.
6. Corrosion.resistant locks and hinges.
7. Oil could be drained via valve and a hose.
8. Exhaust system on the canopy.
9. Special large access doors for easy maintanance.
10. The cap on the canopy provides easy accsess to
radiator cap.
11. Lifting points similar to ISO container, located on
each top corner of the Canopy.
12. Sound proofing materials.
13. Fuel tank is at front of the canopy ,easy access to the
fuel tank via lockable door.
14. Integrated ladder built in toside of the canopy allows
access to the top of the canopy.
INTRODUCTION
Sound-attenuated and weather protective enclosures for generating sets from Aksa, meet event the sound requirements
and provide optimum protection from inclement weather and development by our specialist acoustic engineers. Our
modular designed sound insulated canopies provide ease of access for servicing and general maintenance and
interchangeable components permitting on-site repair. Enclosures are designed to optimize genset cooling performance,
providing you with confidence that genset ratings and ambient capability.

Control Panel
Control Module DSE
Control Module Model DSE 7320
Communication Ports MODBUS

1. Menu navigation buttons


2. Close mains button
3. Main Status and instrumentation display
4. Alarm LED's
5. Close generator button
6. Status LED's
7. Operation selecting buttons

Devices
DSE, model 7320 Auto Mains Failure control module Static battery charger Emergency stop push button and fuses for
control circuits
CONSTRUCTION and FINISH
Components installed in sheet steel enclosure.
Phosphate chemical, pre-coating of steel provides corrosion resistant surface
Polyester composite powder topcoat forms high gloss and extremely durable finish
Lockable hinged panel door provides for easy component access
INSTALLATION
Control panel is mounted generating set baseframe on robust steel stand or power module. Located at side of generating
set with properly panel visibility.
GENERATING SET CONTROL UNIT

Manufacturer reserves the right to make change in the model, technical specifications, color, equipment, accessories and images without prior notice. (05.12.2019)
The DSE 7320 conrol module is a standard addition to our generator sets from 220 kVA upwards and it has been
designed to start and stop diesel andgas generating sets that include electronic and non electronic engines.
The DSE 7320 includes the additional capability of being able to monitor a mains (utility) supply and is therefore suitable
for controlling a standby generating set in conjunction with an automatic transfer switch.
The DSE7320 also indicates operational status and fault conditions, automatically shutting down the generating set and
indicating faults by means of its LCD display on the front panel.
STANDARD SPECIFICATIONS
Microprocessor controlled
- 132 x 64 pixel LCD display makes information easy to read
- Front panel programming and also via PC software
- Soft touch membrane keypad and five key menu navigation
- Remote communications via RS232, RS485 and ethernet.
- Event logging (50) showing date and time
- Multiple date and time engine exercise mode and maintenance scheduler
- Engine block heater control.
- Controls; stop, manuel, auto, test, start, mute lamb test/transfer to generator, transfer to mains, menu navigation.
Instruments
ENGINE
Engine speed
Oil pressure
Coolant temperature
Run time Battery volts
Engine maintenance due
GENERATOR
Voltage (L-L, L-N)
Current (L1-L2-L3)
Frequency
Earth current
kW
Pf
kVAr
kWh, kVAh, kVArh
Phase sequence
MAINS
Voltage (L-L, L-N)
Frequency
WARNING
Charge failure
Battery under voltage

Manufacturer reserves the right to make change in the model, technical specifications, color, equipment, accessories and images without prior notice. (05.12.2019)
Fail to stop
Low fuel level (opt.)
kW over load
Negative phase sequence
Loss of speed signal
PRE-ALARMS
Low oil pressure
High engine temperature
Low engine temperature
Over /Under speed
Under/over generator frequency
Under/over generator voltage
ECU warning
SHUT DOWNS
Fail to start
Emergency stop
Low oil pressure
High engine temperature
Low coolant level
Over /Under speed
Under/over generator frequency
Under/over generator voltage
Oil pressure sensor open
Phase rotation
ELECTRICAL TRIP
Earth fault
kW over load
Generator over current
Negative phase sequence
Options
High oil temperature shut down
Low fuel level shut down
Low fuel level alarm
High fuel level alarm
EXPANSION MODULES
Editional LED module (2548)
Expension relay module (2157)
Expansion input module (2130)

Manufacturer reserves the right to make change in the model, technical specifications, color, equipment, accessories and images without prior notice. (05.12.2019)
Standards
Elecrical Safety / EMC compatibility
BS EN 60950 Electrical business equipment
BS EN 61000-6-2 EMC immunity standard
BS EN 61000-6-4 EMC emission standard
STATIC BATTERY CHARGER
Battery charger is manufactured with switching-mode and SMD technology and it has high efficincy.
Battery charger models' output V-I characteristic is very close to square
2405 has fully output shot circuit protection and ıt can be used as a current source.
2405 charger has high efficiency, long life, low failure rate, light weight and low heat radiated in accordance with linear
alternatives.
The charger is fitted with a protection diode across the output.
Charge fail output is available.
Connect charge fail relay coil between positive output and CF output.
Input: 196-264V.
Output: 27,6V 5A or 13,8V 5A.

STANDARD SPECIFICATIONS
- Heavy duty, water cooled diesel engine
- Radiator with mechanical fan
- Protective grille for rotating and hot parts
- Electric starter and charge alternator
- Starting battery (with lead acid) including rack and cables
- Engine coolant heater
- Steel base frame and anti-vibration isolators
- Spare external fuel tank (open set)
- Flexible fuel connection hoses
- Single bearing, class H alternator
- Industrial exhaust silencer and steel bellows supplied separately
- Static battery charger
- Manual for application and installation

OPTIONAL EQUIPMENTS
TRANSFER SWITCH

- Three or four pole motor operated circuit breaker

- Four Pole Contactor

- Three Pole Contactor

OTHER ACCESSORIES

- Tool kit for maintenance

- Inlet and outlet acoustic baffles

- Inlet and outlet motorised louvers

Manufacturer reserves the right to make change in the model, technical specifications, color, equipment, accessories and images without prior notice. (05.12.2019)
- Automatic transfer switch

- Main Fuel Tank

- Supplied with oil and coolant - 30 °C

- Low and high fuel level alarm

- Electrical oil drain pump

- Automatic or manual fuel filling system

- Duct adapter ( on radiator)

- Enclosure: weater protective or sound attenuated

- Residential silencer

CONTROL SYSTEM

- Remote communication with modem

- Alarm output relays

- Charge Ammeter

- Earth fault, single set


- Remote relay output

- Paralel system with mains.

- Automatic synchronising and power control system ( multi gen-set

Parallel )

- Remote annunciator panel

- Transition synchronization with mains

ENGINE

- Oil heater

- Fuel-Water Seperator Filter

- Remote Radiator Cooling

ALTERNATOR

- Main line circuit breaker

- Over sized alternator

- Anti-Condensation Heater

AKSA CERTIFICATES
- TS ISO 8528
- CE
- SZUTEST
- 2000/14/EC

Manufacturer reserves the right to make change in the model, technical specifications, color, equipment, accessories and images without prior notice. (05.12.2019)