Dynapar R111

The document describes the function and installation of the new Dynapar Tacho generator-R111, which converts shaft rotation into electrical signals to measure generator RPM. It highlights the advantages of the Dynapar system over the Heidenhain tacho generator, particularly its use of a hollow bush for coupling to prevent damage from misalignment. Additionally, it provides pin configuration details for both tacho generators.

Uploaded by

VINOD KUMAR P
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
19 views3 pages

Dynapar R111

The document describes the function and installation of the new Dynapar Tacho generator-R111, which converts shaft rotation into electrical signals to measure generator RPM. It highlights the advantages of the Dynapar system over the Heidenhain tacho generator, particularly its use of a hollow bush for coupling to prevent damage from misalignment. Additionally, it provides pin configuration details for both tacho generators.

Uploaded by

VINOD KUMAR P
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 3

New DYNAPAR Tacho generator-R111

Function of the Tachogenerator:

It is a measuring device, convert shaft rotation into electrical signals. In our


system it measures the Generator rpm and gives the output to Controller & SFS module.

Installation of New type tachogenerator:

Dynapar type tacho generator installed to avoid the broken of tacho generator
shaft and the tachogenerator coupling due to misalignment.

Comparison of Heidenhain and Dynapar tacho Generator

Over view of the both tacho generator

Heidenhain tacho generator Dynapar tacho Generator

To couple Dynapar tacho generator with extension shaft instead of coupling it directly fit
with special type shink bush provided in tacho generator. So it perfectly fixed with that
hollow bush.So it avoid damages in coupling and in extension shaft.
Coupling

In Daynapar type tacho generator, hollow bush is used to connect the generator shaft and
tacho generator instead of coupling.

Tappad shaft
Dynapar tachogenerator Arrangement in Loc R111

Flexible rod

To arrest liner and longitudinal motion, they provide special flexible rod.

Pin configurations

Heidenhain tacho generator Dynapar tacho generator

24v +ve - pin no 2&12 24v +ve - pin no 12


-Ve - pin no 10&11 - ve - pin no 10
Signal - pin no 6 Signal - pin no 8

Hubner Tacho generator

24v +ve - pin no 12


- Ve - pin no 10
Signal - pin no 5