The document contains multiple incident reports from the South Central Railway's Secunderabad Division dated 24-05-2025, detailing various operational issues including stalling, loco trouble, wheel slipping, and a man run over incident. Each report includes specifics such as train numbers, locomotive details, causes, and chronological occurrences of events. The reports highlight the challenges faced during operations, particularly due to weather conditions and mechanical failures.

Uploaded by

kirru812
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
25 views6 pages

Page 13 2

The document contains multiple incident reports from the South Central Railway's Secunderabad Division dated 24-05-2025, detailing various operational issues including stalling, loco trouble, wheel slipping, and a man run over incident. Each report includes specifics such as train numbers, locomotive details, causes, and chronological occurrences of events. The reports highlight the challenges faced during operations, particularly due to weather conditions and mechanical failures.

Uploaded by

kirru812
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

SOUTH CENTRAL RAILWAY

SECUNDERABAD DIVISION
SECUNDERABAD

STALLING REPORT 24-05-2025


Date of Incident 24-05-2025 Loco-1/Type/Base: 31257 WAG9 GMO
Incident type STALLING Loco-2/Type/Base:

Train No BPCL/BTPN Load 52/52/3924 Gradient 1 in 100

Section KZJ-SNF Location KZJ-PQL


Detention 25" Punctuality Loss .
Repercussion .
Cause of Incident .
Reason STALLING
Reported to DIVISION
Locomotive Details LP ALP
Loco1 Loco2 Name P.NAGARAJU ANJANEYULU A
31257 Designation/HQRS LPG/SNF1201 ALP/SNF3252
WAG9 GMO Gradation / Ph No. B/918790993226 -/9063331505
DOB 06-02-1977 18-08-1996
TOH DONE 28/03/2025
DOA 08-06-2006 18-04-2022
IA DUE 27/06/2025 ITI
EQ B.Tech
DOP 09-06-2014 25-04-2023
PME DUE 03-01-2026 25-04-2027
GSR DUE 17-01-2026 25-07-2025
TECH DUE - D/E 16-06-26/26-11-25 25-06-25/-
Last Monitoring Date
LI Name B.R.PAWAR S.V.M.KRISHNA
Chronological order of occurance:
W/O banker memo given
01:10 Train started from R1 KZJ yard
01:20 LP informed that train stopped at Km No 323/1 due to continuous wheel slip due to drizzling weather
01:25 Started to back the train after taking P.N no-85 from RRI/KZJ
01:51 Fouling cleared to R1
Conclusion:
Responsibility:
SOUTH CENTRAL RAILWAY
SECUNDERABAD DIVISION
SECUNDERABAD

LOCO TROUBLE REPORT 24-05-2025


Date of Incident 24-05-2025 Loco-1/Type/Base: 31442 WAG9 LGD
Incident type LOCO TROUBLE Loco-2/Type/Base:

Train No 07256 Load 24 COACHES Gradient 1 in 150

Section KZJ-BPQ Location PPZ-MCI


Detention 58" Punctuality Loss 07075
Repercussion .
Cause of Incident .
Reason LOCO TROUBLE
Reported to DIVISION
Locomotive Details LP ALP
Loco1 Loco2 Name B.SOMAIAH NEERAJ KUMAR
31442 Designation/HQRS LPG/KZJ2855 SALP/KZJ3192
WAG9 LGD Gradation / Ph No. B/918790992532 -/919963143962
DOB 13-05-1978 18-08-1993
IC DONE 28/04/2025
DOA 16-05-2000 21-01-2016
IA DUE 27/07/2025 ITI
EQ ITI
DOP 14-12-2015 28-06-2023
PME DUE 08-05-27 24-02-28
GSR DUE 18-12-27 09-09-2026
TECH DUE - D/E 23-04-28 27-04-27
Last Monitoring Date
LI Name M RAJENDER D.POCHAIAH
Chronological order of occurance:
03:23 PPZ departure.
03:34 After passing neutral section smell observed in from machine room near SR1, mean while message external earth fault in
converter-1,DJ tripped
Train stopped at KM no:261/2 due to DJ not holding
Made CE OFF/ON, traction bogie-1 isolated, trouble rectified
03:40 Train departure from spot with 3 TM's, due to 1 IN 150 raising gradient and heavy rain extra time taken
04:08 MCI main line arrived.
Planned RE from MCI loop line by cancelled tr no:ADB
RE no:31423/DDU
04:20 RE made EOT.
04:38 Train departure from spot

Found in loco no:31442/LGD water leakage from loco roof at carridor and both cabs
Conclusion:
UUO REPORTED IN ASSET AND BULLETIN
Responsibility:
SOUTH CENTRAL RAILWAY
SECUNDERABAD DIVISION
SECUNDERABAD

WHEEL SLIPPINGREPORT 24-05-2025


Date of Incident 24-05-2025 Loco-1/Type/Base: 32990 WAG9 CNB
Incident type WHEEL SLIPPING Loco-2/Type/Base:

Train No NTPG Load 59/59/5255 Gradient RAINY

Section BZA-DKJ Location PPY-DKJ


Detention 30" Punctuality Loss .
Repercussion 20625, 12739, 12578, 20809
Cause of Incident .
Reason Others
Reported to DIVISION
Locomotive Details LP ALP
Loco1 Loco2 Name K.DURGA NARAYANA CH NAGA SURESH
32990 Designation/HQRS LPG/GALA1263 SALP/GALA1675
WAG9 CNB Gradation / Ph No. B/918790992234 -/916309921796
DOB 20-05-1975 15-06-1994
IB DONE 25/03/2025
DOA 11-08-2004 09-03-2021
IC DUE 23/06/2025 ITI
EQ B.Tech
DOP 12-07-2012 29-06-2023
PME DUE 07-06-26 25-07-27
GSR DUE 17-09-2025 05-06-27
TECH DUE - D/E 03-11-25 04-05-27
Last Monitoring Date
LI Name POLURI BALA KRISHNA N.MoshePOLURI BALA K
Chronological order of occurance:
03:31 Train left from PPY L/L
T.No - 6/72 without banker
03:44 LP informed that train stopped at Km No 464/17 due to continuous wheel slip since rain
03:54 Started to back the train after taking P.N No 60 from Dy.SS/PPY
04:14 PPY M/L fouling cleared
Conclusion:
Responsibility:
SOUTH CENTRAL RAILWAY
SECUNDERABAD DIVISION
SECUNDERABAD

REPORT
CARRIAGE AND WA 24-05-2025
Date of Incident 24-05-2025 Loco-1/Type/Base: 30475 WAP7 RPM
Incident type CARRIAGE AND WAGON Loco-2/Type/Base:

Train No 17648 Load . Gradient .

Section PRLI STATION Location PRLI STATION


Detention . Punctuality Loss .
Repercussion .
Cause of Incident .
Reason Others
Reported to DIVISION
Locomotive Details LP ALP
Loco1 Loco2 Name SANDEEP KUMAR SINH .
30475 Designation/HQRS LPG/PRLI1157
WAP7 RPM Gradation / Ph No. C/916309921794
DOB 22-08-1990
IOH DONE 07/04/2025
DOA 10-11-2016
IA DUE 06/07/2025 EQ ITI
DOP 28-10-2023
PME DUE 24-10-28
GSR DUE 26-04-28
TECH DUE - D/E 10-12-25
Last Monitoring Date
LI Name B.RATNA RAJU
Chronological order of occurance:
10:11 17648 Exp arrived on PF-3
10:21 Shunter TOC (due to shunter engaged in 16594)
10:45 While making EOT cab-2 T/S coupling handle struck up
10:48 - 10:58 Later C&W staff attended
11:00 Made EOT
11:09 Train departured from the spot
Conclusion:
Responsibility:
SOUTH CENTRAL RAILWAY
SECUNDERABAD DIVISION
SECUNDERABAD

MAN RUN OVER REPORT 24-05-2025


Date of Incident 24-05-2025 Loco-1/Type/Base: 401006,12,14
Incident type MAN RUN OVER Loco-2/Type/Base:

Train No 47234 Load . Gradient .

Section SNF-SC Location HSJ-SC


Detention . Punctuality Loss .
Repercussion .
Cause of Incident .
Reason Others
Reported to DIVISION
Locomotive Details LP ALP
Loco1 Loco2 Name M.SHIVALKAR .
401006,12,14 Designation/HQRS LPG/SC1742
Gradation / Ph No. A/919346901639
DOB 01-07-1975
DOA 27-06-2000
EQ DME
DOP 06-05-2008
PME DUE 05-04-2025
GSR DUE 02-04-2024
TECH DUE - D/E 25-06-24/01-12-15
Last Monitoring Date
LI Name Sk.Abdullah
Chronological order of occurance:
11:16 Train departured from HSJ
11:20 A male tresspasser runover at Km No 191/14-16
Body struckup under front wheel (left side)
12:28 After RPF & GRP removed the body train left the spot
Conclusion:
Responsibility:
SOUTH CENTRAL RAILWAY
SECUNDERABAD DIVISION
SECUNDERABAD

LOCO TROUBLE REPORT 24-05-2025


Date of Incident 24-05-2025 Loco-1/Type/Base: 37803 WAP7 KJM
Incident type LOCO TROUBLE Loco-2/Type/Base:

Train No 12251 Load 22 Coaches Gradient .

Section KZJ-BPQ Location PTKP


Detention 102" Punctuality Loss
Repercussion NIL
Cause of Incident
Reason LOCO TROUBLE
Reported to DIVISION
Locomotive Details LP ALP
Loco1 Loco2 Name G.HARIBABU NARAYAN DAS
37803 Designation/HQRS LPM/SC1913 SALP/SC2930
WAP7 KJM Gradation / Ph No. A/918790992979 -/918790992593
DOB 10-06-1970 03-04-1995
IA 10-05-2025
DOA 13-05-1996 09-10-2019
IB 27-07-2025 DIPLOMA
EQ DIPLOMA
DOP 22-06-2017 29-06-2019
PME DUE 11-12-25 19-04-2027
GSR DUE 12-09-27 02-09-2025
TECH DUE - D/E 03-11-25 08-02-26/-
Last Monitoring Date
LI Name PEDAPUDI NAGESWAR D.UPENDER
Chronological order of occurance:
14:46 LP informed while approaching PTKP OCR-78 acted cleared section PTKP on coasting
After arrival PTKP checked no abnormality in loco
and resetted the OCR-78. but After 504 node UBA showing zero '0' and message
" Communication Link Fail", tried by CE OFF & ON ,BA OFF /ON but not rectified
Tried by Isolating Bogie I & II but not rectified
Tried from rear cab but not rectified
14:51 RE asked
15:20 RE-32071/BSL PDPL departure
15:55 RE arrived PTKP Loop-line
16:10 EOT
16:20 Ready
16:28 Departure
CE OFF & ON, BA OFF & ON but not rectified.
As per ADEE Shri.Abdin sir instructions 127/126 knobs operated but not rectified
As per KJM shed loco failed.
Conclusion:
UUO REPORTED IN ASSET AND BULLETIN
Responsibility:

You might also like