TECHNICAL DATA SHEET
Electrochemistry
Benchtop Multi-Parameter Meter
                                                                                                                                               Complete Simplicity
                                                                                                                                               Hach sensION+, an
                                                                                                                                               all-in-one system with
                                                                                                                                               guided menu navigation
                                                                                                                                               makes general
                                                                                                                                               electrochemistry testing
                                                                                                                                               fast and simple. Each
                                                                                                                                               system is designed to be
                                                                                                                                               used in a wide variety of
                                                                                                                                               applications and comes
                                                                                                                                               complete with
                                                                                                                                               everything you need to
                                                                                                                                               start testing.
 Features and Benefits
•                           is a high performance instrument that                        • In addition, there is a connection for a second stirrer which allows
    combines a pH meter, an ion meter, and a conductivity meter.                           for a second measuring stand.
• Multi-parameter instrument with two measuring channels: Channel 1,                     • Data logger-Storage of up to 330 measurements per channel.
  pH and Conductivity with temperature ºC; Channel 2, pH, ORP/Redox                      • Includes RS 232 C connectibility for printer or PC as well as a connection
  or I.S.E. + ºC                                                                           for external PC keyboard or barcode reader.
• It is supplied with magnetic stirrer, calibration flasks, pH buffers and
  conductivity standard solutions.
 Recommended Sensors
pH Electrode
LZW5014.97.0002: 5014 Universal and high performance, for general
aqueous samples, sulfurs, reducing sugars or applications that react with silver ions.
• Refillable
• Thick glass body
• 2 ceramic junctions
• High performance electrode with encapsulated reference element and                                              50 70
                                                                                                                      -30... 80ºC
  Ag+ ion barrie
                                                                                                                      0.2... 200.000 µS/cm
• pH 0 to 14, Temp. -10 to 100ºC (14 to 212ºF)
Conductivity Cell
LZW5070.97.002: 5070 Universal, for general aqueous samples.
• Includes 3 platinum electrodes, 2 pole cell
• With 8 contact telephone connector
• Includes temperature sensor Pt 1000
  C≈0.7 cm-1. EC 0.2 to 200.000 uS/cm, Temp. -30ºC (-22º F) to 85ºC (185ºF)
                                                                                                                50 70                        50 14
                                                                                                                                             At Hach, it’s about learning from
 Specifications                                                                                                                              our customers and providing the
                                                                                                                                             right answers. It’s more than ensu-
                         Measurement Ranges                       Resolution             Input Accuracy             Reproducibility
                                                                                             (± 1 digit)                 (± 1 digit)         ring the quality of water— it’s
 pH                                -2 to 16
                                                                                                                                             about ensuring the quality of life.
                                                                0.1/0.01/0.001                ≤0.002                      ±0.001
 mV                                 ±2000                             0.1/1                     ≤0.2                       ±0.1              When it comes to the things that
 Temp.                  -20 to 150ºC (-4 to 302ºF)                0.1 ˚C (0.1ºF)          ≤0.2 ˚C (0.4ºF)             ±0.1ºC (0.1ºF)
                                                                                                                                             touch our lives... Keep it pure.
 ISE                          10-6 M to 10-1 M                   programmable                     --                         --              Make it simple.
 Conductivity
                       0.001* µS/cm to 1000* mS/cm
                                                                     variable                 ≤0.5 %                      ±0.1 %
                                                                                                                                             Be right.
                    * With 5070 cell: 0.2 µS/cm to 200 mS/cm
 Resistivity               0 Ohm to 500 MOhm                            --                     ≤0.5%                     ± 0.1 %
 Salinity                5.85 mg/L to 311.1 g/l NaCl                    --                        --                         --
 NaCl                                  --                            variable                 ≤0.5 %                      ±0.1 %
                                                                                                                                             For current price information,
 TDS                         0 mg/L to 500 g/L                       variable                 ≤0.5 %                      ±0.1 %             technical support, and ordering
Temperature Compensation Automatic with temperature probe Pt 1000, NTC 10kOhm.                                                               assistance, contact the Hach office
Programmable isopotential pH, standard value at pH 7.00 EC: TC (temperature coefficient) Linear, 0.00 to                                     or distributor serving your area.
9.99 % /ºC. Non linear for natural waters (UNE EN 27888). TR (ref. temperature) 20ºC (68ºF), 25ºC (77 ºF)
or values between 0 to 99ºC (0 to 210ºF).
                                                                                                                                             In the United States, contact:
pH Calibration Technical buffers DIN 19267: pH 2.00, 4.01, 7.00, 9.21 and 10.01 (values at 25°C)(77ºF).
DIN 19266 buffers: 1.679, 4.006, 6.865, 7.000, 9.180, 10.012 and 12.454 at 25ºC (77 ºF).                                                     HACH COMPANY World Headquarters
Specific user’s buffers.With 1, 2 or 3 buffers selectable inside the range. Calibration at any pH value (indirect                            P.O. Box 389
calibration). Manual introduction of the calibration parameters. Programmable calibration validity between                                   Loveland, Colorado 80539-0389
0 h to 7 days. Automatic rejection of electrodes in poor condition.
                                                                                                                                             U.S.A.
mV Calibration Automatic recognition of redox standard 220 mV at 25ºC (77ºF).
                                                                                                                                             Telephone: 800-227-4224
Calibration at any mV value.
                                                                                                                                             Fax: 970-669-2932
ISE Calibration 2 to 5 programmable standards.
                                                                                                                                             E-mail: orders@hach.com
Selectable calibration units: mol/L, M, mmol/L, mM, umol/L, g/L, mg/L, ppm and %. Up to 4 calibration curves
per channel.                                                                                                                                 www.hach.com
Conductivity Calibration Standards: 147 µS/cm , 1413 µS/cm, 12.88 mS/cm and 111.8 mS/cm [values                                              U.S. exporters and customers in Canada,
at 25ºC (77ºF)]. Demal, 1409 µS/cm, 12.85 mS/cm and 111.31 mS/cm (25ºC). NaCL 0.05 % (1014.9 µS/cm                                           Latin America, sub-Saharan Africa, Asia,
at 25 ºC). With 1, 2 or 3 standards selectable inside the range. Special calibration at any Conductivity,
                                                                                                                                             and Australia/New Zealand, contact:
salinity or TDS value. Manual introduction of cell constant. Programmable calibration validity between 0
to 99 days.                                                                                                                                  HACH COMPANY World Headquarters
TDS Conversion Factor Values between 0 to 4.44. Default 0.64.                                                                                P.O. Box 389
Temperature Readjustment Correction of the temperature probe deviation (A.T.C.) at 25ºC (77ºF) and                                           Loveland, Colorado 80539-0389
85ºC (185ºF).                                                                                                                                U.S.A.
Data Logger Storage capacity up to 330 readings per channel.                                                                                 Telephone: 970-669-3050
Languages English, German, Spanish, French, Italian and Portuguese.                                                                          Fax: 970-461-3939
Display Graphic, backlit liquid crystal, 128 x 64 dots.                                                                                      E-mail: intl@hach.com
Connectable Sensors 2 combined or indicator electrodes, BNC connector (Imp. >1012Ω).                                                         www.hach.com
2 Reference electrodes, banana connector.
1 A.T.C. type Pt 1000 or NTC 10kOhm.,                                                                                                        In Europe, the Middle East, and
1 Conductivity cell with built-in Pt 1000 sensor, telephone connector.                                                                       Mediterranean Africa, contact:
Connectable Peripherals 2 magnetic stirrers. Printer or PC. External PC keyboard or barcode reader.
                                                                                                                                             HACH LANGE GmbH
Directives Low Voltage and EMC According to 2004/95/EC. According to 2004/108/EC.
                                                                                                                                             Willstätterstraße 11
Power Supply External power supply 100-240 V, 0.4 A, 47-63 Hz, with plug adapters.                                                           D-40549 Düsseldorf
Materials Enclosure, ABS and PC. Keypad, PET with protective treatment.                                                                      GERMANY
Physical Parameters Weight: 1100 g. Size: 350 x 200 x 110 mm.                                                                                Tel: +49 (0) 211 5288-0
 How To Order                                                                                                                                Fax: +49 (0) 211 5288-143
                                                                                                                                             E-mail: info@hach-lange.de
LPV4110.97.0002 Multimeter SensION+ MM374, with accessories                                                                                  www.hach-lange.com
LPV4140T.97.002 Multimeter SensION+ MM374, accessories, electrode 5014 and
conductivity cell 5070.
Included Accessories
        • Magnetic stirrer             • Calibration flasks with magnetic stirring bar
        • Sensor holder                • Solutions: pH 4, pH 7, Conductivity standard 1413 µS/cm 		
        • User manual                    and KCI
Other Accessories:
LZW8201 Thermal printer of 40 columns, interface RS.
LZW8200 Impact printer of 40 columns, interface RS.
Lit. No. 2697 E
Edition 07.10 Printed in U.S.A. ©HACH Company 2009. All rigths reserved.
In the interest of improving and updating its equipment, Hach Company reserves the right to alter specifications to equipment at any time.