Capacitance Point Level Switch ‐ ‘CPLS’
Specially designed, reliable level switch to detect level of
almost all materials, water and similar liquids, coolants,
lubricants, slurries, pastes, powders, grains and granules.
Salient Features
Compact and robust design
Trouble free operation with minimal maintenance
Virtually capable to ignore build‐up on sensor
Simple to teach empty and full level with two buttons.
Easy to configure o/p switching function NO or NC
Teach lock facility for safety operation
Construction and Working
The switch consists of an electrode with full PTFE insulation Schematic Diagram
and microprocessor based integral electronics housed in an
enclosure. It measures the capacitance formed due to
service material within its active area and provides PNP or
NPN switching output.
The CPLS can be also used alongwith Techtrol Switch
Amplifier (TSA), whose relay output can be used for higher
loads like pumps & solenoid valves.
Specifications
Probe MOC : Full PTFE insulated SS304
Probe Length : 150 mm or 300 mm
Active Area : 20 to 30 mm
Process Conn. : 1‐1/2” BSP Screwed or Flanged
Supply : 12 to 28 VDC
Output : PNP or NPN @ 35 mA load
Output Function: Normally Open (NO) or Installation
Normally Closed (NC)
(Settable thru buttons)
Power : 8 mA @ 24 VDC (w/o load)
LED Indication : Red (NC); Green (NO)
Programming : Through two push buttons for
1. Teach Empty (probe uncovered)
or Full Level (probe covered)
2. Selection of switch function NO/NC
3. Teach Lock or Unlock
Enclosure : Cast Al. WP IP65 or ABS IP65
Conduit Conn. : PG 11 Cable Gland (Nylon)
Max Temp : 60 °C
Max Pressure : Atmospheric
Techtrol Switch Amplifier (TSA)
Model : TSA
Enclosure : ABS Panel mounted, IP41
: Size ‐ 72 x 72 x 120 D mm
Enclosure : ABS x IP41 TSA
Supply : 90 – 270 VAC or 24 VDC
Input : PNP or NPN
Output : Relay x 1 SPDT, 5A@250 VAC
: 24VDC for level switch
LED Indication : Green – Supply, Red – Relay Status
Terminations and Wiring
CPLS TSA CPLS
O/P - O/P - L N E + ‐ I/P
90 to 270VAC 24VDC PNP
Supply O/P for
Switch
Potential free relay
NO1 P1 NC1
L = Load
Model Identification
CPLS ‐
Enclosure x Conduit Connection
Cast Al, WP IP66 x PG11 Cable Gland A
ABS, WP IP66 x PG11 Cable Gland B
Process Connection
1‐1/2”BSP Screwed 1
1‐1/2”NB ASME 150# Flange 2
Other O
Output
PNP P
NPN N
Techtrol Switch Amplifier
Provided W
Not Provided P
Ordering Information
Model No. x service material, operating temperature & pressure.
Pune Techtrol Pvt Ltd [CIN: U31909PN1991PTC063403]
S‐18, MIDC, Bhosari, Pune ‐ 411026. India. Ph: +91‐20‐66342900, ho@punetechtrol.com, www.punetechtrol.com
Works: J‐52/7, MIDC, Bhosari, Pune ‐ 411026. India +91‐20‐67313600
CAT/ 132/ REV 00/ 05‐2022