Bypass level indicator, liquid gas/KOPlus version, model BNA-L
Bypass chamber from stainless steel
150
Specifications
Bypass chamber Ø 88.9 x 2 mm, max. 25 bar
Ø 88.9 x 2.9 mm, max. 40 bar
~42 Chamber end top
Flange connection
Options: (see page 14)
Vent screw
A A
Vent valve
80
Vent flange
Chamber end bottom
Flange connection
Options: (see page 14)
Drain plug
Drain valve
Drain flange
Process connections 2 x lateral (options see page 15)
Flange EN 1092-1, DN 10 - DN 100,
PN 6 - PN 63
M ...
Flange DIN, DN 10 - DN 100, PN 6 - PN 64
Flange ANSI B 16.5, 1/2" - 4",
class 150 - class 600
Weld stub 1/2" - 1"
Threaded bushing G/NPT 1/2" - 1"
Threaded nipple G/NPT 1/2" - 1"
Centre-to-centre distance Min. 150 mm to max. 6,000 mm (larger distances
on request)
Material Stainless steel 1.4571 (316Ti)
(Ø 88.9 x 2 mm, Ø 88.9 x 2.9 mm)
Stainless steel 1.4404 (316L) (Ø 88.9 x 2 mm)
Nominal pressure Max. 40 bar
Temperature range -60 ... +300 °C
U
Float Cylindrical float, model BFT-H, see data
sheet LM 10.02
Magnetic display Standard version, model BMD-S: < 200 °C
High-temperature version, model BMD-F:
> 200 °C, see data sheet LM 10.03
~42
Level sensor Reed sensor, model BLR, see data sheet
LM 10.04
Magnetostrictive sensor, model BLM, see data
A-A sheet LM 10.05
Guided wave radar, model GTR (for KOPlus
M = centre-to-centre distance of the version), see data sheet LM 20.05
process connections Magnetic switches Magnetic switch, model BGU, see data sheet
U = float length (min. 220 mm) LM 10.06
Approvals Ex c, GOST-R
Special versions on request
KOPlus version
Page 10 of 16 WIKA data sheet LM 10.01 ∙ 01/2015