Service Manual: Refrigerator
Service Manual: Refrigerator
: FR510P0010
Service Manual
Refrigerator
Model: FR-510M
FR-540M
FR-510P
FR-540P
✔ Caution
: In this Manual, some parts can be changed for improving, their
performance without notice in the parts list. So, if you need the
latest parts information,please refer to PPL(Parts Price List) in
Service Information Center (http://svc.dwe.co.kr).
2. External view-----------------------------------------------------------------------------------------------2
4. Name of parts--------------------------------------------------------------------------------------------- 4
8. Main components----------------------------------------------------------------------------------------- 8
1. FR-510M
770 700
760
22
31.5
760
24
568
511
595
60
11
1422.5
1741
988
1039
770
53
121
136
3
24 712 24
2. FR-540M
770 700
760
22
31.5
760
24
568
511
595
11
60
1768
1422.5
1015
1066
770
53
121
136
24 712 24
1. FR-510M, 540M
TEMP
GRAY FUSE BLACK
COMPRESSOR
DEFROST A M BLUE
PINK
HEATER 4
3
SWITCH
DOOR
1 L/BLUE
2 RED
PTC OL
WHITE
P-RELAY
R-LAMP GN/YW
BIMETAL RED PLUG
WHITE
1 2 BROWN R-LAMP
M
BROWN
FM F-LAMP
3 4 RED RED
BLACK
WHITE/BLUE YELLOW
TEMP
CONTROLLER
2. FR-510P, 540P
M-PCB
YELLOW YELLOW
GREEN
BROWN RED
WHITE
WHITE WHITE
BLUEX3
RED
BLACK WHITE F-LAMP
VIOLET RED RED
BROWN
BLUE
DEFROST
YELLOW
YELLOW
BLACKx2 VIOLET 21 3 4
HEATER DOOR
SWITCH BROWN
GRAY P-RELAY
GRAYx2 BLACK FM GN/YW
BLUE
DOWN
TRANS TEMP BLACK R-LAMP
FUSE PULG
ORANGE BLUE
x2 x2 R-LAMP M A
BLUE L/BLUE
BLACK BLACK
F-SENSOR
D-SENSOR
F-PCB COMPRESSOR
BLACK
1. FR-510M, 540M
2. FR-510P, 540P
770 700
760
24 22
760
31.5
568
511
595
60
11
1422.5
1741
988
1039
770
53
121
136
3
24 712 24
4. FR-540P
770 700
760
24 22
760
31.5
568
511
595
11
60
1768
1422.5
1015
1066
770
53
121
136
24 712 24
-17~-19
Refrigerating room
Cold air absorbing duct
This model is multi-flow type
Do not place food in front
which flows out cold air from
of the duct because it is the
each shelf space. The hot air
entrance of the cold air.
A after making the refrigerator
2~4 cold, flows into cooling system
2~4 1~3
through the front upper part.
Refrigerator door pocket
Temperature is high even if the B
3~5
pocket is in the middle. 2~4 1~3
When storing margarine or cheese
for one or two weeks, make use C Do not put food having much
of the refrigerator shelf. 3~5
2~4 2~3 moisture at the middle part of
each shelf space ("A", "B" and
"C" part). It can be frozen owing
Crisper 5~7
to the low temperature.
Suitable in storing fruits or
vegetable.
Wrapping can prevent from
dryness.
PIPE
HOT ACCUM
OSS
PIPE FIN CR
UX-HOT EVA
A
AUX-HOT PIPE
SUC-PIPE
ER
DRY
COMP
C A H A B D C E A S
O U O U A R A V C U
M X T X C
K Y P A C C
P I I E I P U
R C P H P
E O I O R O M P
L
S N P T A T R U I
S E T U A L P
O P P E B T A E
R I I E O T
P P P R O
E E I R
P
E
COOLING PIPE
19 11
16
13 7
21
20
17
15 8
12
18
6
5 9
22 10
1 2 3 4 14
Refrigerant R134a
Voltage 100V/50,60Hz 110V/60Hz 115, 120V/60Hz 127V/60Hz 220V/50Hz 220V/60Hz 230V/50Hz 240V/50Hz
Comp. model HBL25YE-C HBL25YE-3-C HBL25YE-2-C HSL27YE-5-C X HSL27YE-5-C
Part code 3952125L00 3952125L30 3952125L20 3954127L50 X 3954127L50
Strating type CSR CSR CSR RSIR X RSIR
2. RELAY ASSEMBLY
Refrigerant R12
Voltage 100V/50,60Hz 110V/60Hz 115, 120V/60Hz 127V/60Hz 220V/50Hz 220V/60Hz 230V/50Hz 240V/50Hz
Relay model X X 317THBYY-52 276THBYY-52 197SHBYY-52 276THBYY-52
Part code X X 3018112000 3018105641 3018104102 3018105641 3018105641
Refrigerant R134a
Voltage 100V/50,60Hz 110V/60Hz 115, 120V/60Hz 127V/60Hz 220V/50Hz 220V/60Hz 230V/50Hz 240V/50Hz
Relay model 801RFBZZ-52 445RHBZZ-52 317THBYY-52 276THBYY-52 X 276THBYY-52
Part code 3018101630 3018101620 3018112000 3018105641 X 3018109901 3018105641
3. RUNNING CAPACITOR
Refrigerant R12
Voltage 100V/50,60Hz 110V/60Hz 115, 120V/60Hz 127V/60Hz 220V/50Hz 220V/60Hz 230V/50Hz 240V/50Hz
Spec. X X 300V/7µF X 350V/5µF X X
Part code X X 3816800400 X 400EL15110 X X
Refrigerant R134a
Voltage 100V/50,60Hz 110V/60Hz 115, 120V/60Hz 127V/60Hz 220V/50Hz 220V/60Hz 230V/50Hz 240V/50Hz
Spec. 200V/12µF 300V/7µF X X X X
Part code 3816801910 3816800400 X X X X
4. STARTING CAPACITOR
Refrigerant R12
Voltage 100V/50,60Hz 110V/60Hz 115, 120V/60Hz 127V/60Hz 220V/50Hz 220V/60Hz 230V/50Hz 240V/50Hz
Spec. X X 200V/100µF X X 290V/50 µF X
Part code X X 401RD35050 X X 4124G62020 X
Refrigerant R134a
Voltage 100V/50,60Hz 110V/60Hz 115, 120V/60Hz 127V/60Hz 220V/50Hz 220V/60Hz 230V/50Hz 240V/50Hz
Spec. 200V/100µF X X 290V/50 µF X
Part code 401RD35050 X X 4124G62020 X
6. DEFROST HEATER
7. LAMP ASSEMBLY
11. DRYER
10
5 3011300801 BP-3PIN
* Upper power cord’s part code is only for lead wire, without any kinds of terminal or housing.
11
1. FR-510M, 510P
1. ASSEMBLY URETHAN FREEZER DOOR
1) FR-510M
2) FR-510P
2. FR-540M, 540P
1. ASSEMBLY URETHAN FREEZER DOOR
1) FR-540M
2) FR-540P
12
1 P/WITH (WH069)
7 M. D/GRAY (GY750)
8 N/BLUE (BL718)
13
1 P/WITH (WH069)
7 M. D/GRAY (GY750)
8 N/BLUE (BL718)
10 S/GOLD
11 G/GREEN
14
15
16
17
18
19
20
✔ Caution : In this Service Manual, some parts can be changed for improving, their performance without notice in the parts list.
So, if you need the latest parts information, please refer to PPL (Parts Price List) in Service Information Center
(http://svc.dwe.co.kr)
21
22
23
24
1. FR-510P, 540P
1) How to use the panel
• Quick freeze function operates for 150 • By pressing the Freezer Compartment Temp.
minutes to quickly freeze food or make ice. adjust button, you can set the temp; warm,
mid warm, normal, mid-cold or cold.
• The Clock displays "150 minutes" for 8
seconds and then displays time again. • When you press the time set button and
then the time adjust button HOUR and
• Press the button again in 8 seconds to stop
MINUTE can be set.
the quick freeze function.
• Pressing the button while it shows time,
displays a remaining quick freeze time for 8
seconds.
25
Control Control
NO. Contents Remark
Function Objects
3 Quick COMP. 1. When press the quick freezing button at 1:05 AM, quick
freezing F-fan freezing time of 150 min. will display for 8 sec., and then
C-fan return to 1:05 AM.
LED ç Pressing the button again in 8 sec. will cancel the function.
26
COMP ON
N
COMP OFF
N
9° C Refrigerator
R-sensor Compartment
Operational Temp.
Temp.
4° C
R-sensor
inoperable
Temp.
27
6 Economic COMP. 1. When the economic freezing button is pressed the LED lights
F-fan and the operation is started.
freezing C-fan
QUICK FREEZER TEMP. CONTROL ECONOMIC
LED
TIME SET
FREEZING TIME ADJUSTER FREEZING
AM FRESH
FRZ. EF
CLEAN
7 Defrost COMP. 1. When 9 hours of accumulated time passed, the defrost starts
mode Heater nuconditionally.
F-fan 9 hours start defrost
C-fan
6 hours
COMP. Minimum Maximum
accumulated accumulated accumulated
start time time time
28
8 Forced COMP. 1. Press the quick freezing button 5 times, when press time set
defrost F-fan button and then forced defrost mode is started.
QUICK FREEZER TEMP. CONTROL ECONOMIC
TIME SET
FREEZING TIME ADJUSTER FREEZING
AM FRESH
FRZ. N
CLEAN
10 Error LED 1. Press the quick freezing button 5 times, when press both the
display freezer temperature button and then each sensors’
temperature and error code is displayed for 8 min.
QUICK FREEZER TEMP. CONTROL ECONOMIC
TIME SET
FREEZING TIME ADJUSTER FREEZING
FRESH
FRZ. C
CLEAN
29
D0 Door switch - When the door switch is left - The F-fan operates irrespective of the door
malfunction open continually for an hour. switch when the compressor is on.
30
R61
R05
R06
R01
R02
R03
R04
R07
7812
23
24
11
11
11
13
17
8
7
R5 37.4K
9
7
3
GN R47 GY
R24 C3 C40 B02
IC1 IC3 13 13 6 C43
WHRED R43 24 C1 ERROR
62308 62308 DATA 30.1K 0.1µF GY
12 1 C15 5V
12
13
12
13
3
33.2K
15
10
7
2
4
R43 R7
7
7
8
4
10
12V BK
IC4
13
14
2
3
12
WHPK
12
R44 25 R-S
7
R25 R8
IC9
470µF
IC7
1000µF PCB TRANS
15 4
DATA PREVENT OVER C19 30.1K
0.1µF
7805 7812
R43 ICE R9 20.5K C3 C10 C2 D5 BL
B01
62783
C12 C17 YT
16 5 R26 R10
11 11 R44 8 0.1µF 0.1 µF 0.1µF
BA1 BA2 - g3 g2 g1 17 6 WHBL 26 R-S ON 5.4V
FRESHNESS DATA C20 30.1K IC8
18 7 BL
R51 R19 24.3K 0.7
i f3 f2 f1
11
8
9 10 10 R28 R20 7806 BK
MID.HIGH R52 37 10 C1
10 WHBK R-S OFF C13 R79
DATA 30.1K 0.1mf YFW-800-03
C22
R53 CN2 YT 3 1
Quick F-FAN
Freezing LOW MID P.M. A.M. e3 e2 e1 9 9 R54 R2 VAR1
WH 38 FUSE BK DOOR
26.3K
R20
R30
R31
R32
DATA
HIGH BA10 BA9 d3 d2 d1
12V R55
RT1 R77 1.5A S/W
12 4 17.8X 5YC581 RED
X7 R12 R75
8 8 R56 11 11 2 14.3K
MID BA8 BA7 c3 c2 c1
GY 39
DATA IC1 12 10
X6
X5
5
R14
C3202
Q01 BL 4 RED 2
TWP 47C350N 13 9 1 23.2K
4051
R80
12V
AC300Y
X4
FREEZING 5 5 34 12 R15 23.2K 1K
BL 14 8
LOW BA6 BA5 ROOM b3 b2 b1 C39
VCC X3
C41 SN1
DEODORIZATION 3 15 R16 28.6K YW
C7 X2
7 14 R17 41.2K
BA4 BA3 a3 a2 a1 6 X1
Economic IC05 13 R18 24.9K
8 FAN RELAY
5V
7805
X0
RY3 R LAMP F LAMP
9 R27
R55
F - PCB C1
C2 7
YT
7 GND
R55
46
DEFROST
OPTION
FREQUENCY
55
C21
D8
314145
YFW-800-06
P-RELAY
BK
CN1 YW
INPUT
R57
47 ICE MAKER GN
OPTION
COMP
R55 RY1 GN
PK PK
IC2
C33 43 5 12
20 µF 50 FAN1 D9
X-IN 34 3 14 COMP RELAY WH
S/C
X-TAL 4
COMP 33 13
51 HTR 36 1 16 RY2
82304
X-OUT
41 6 17
20 µF C34 52 42 7 D10 MTR GLASS GY TEMP FUSE
HOLD 20 HTR RELAY
SN3AC300Y
35 2 25
19 D-TIME C-FAN 70+/-5 Co
15 3
R40 OPTION
1K 20
(DIFF) 40
21 44
CN10 YFW-800-01
1K
D-TIME 53 R-FAN
R41 22 OPTION 54 RY4
(WIN) PK
R71 1K 50 55
FAN 57 D4
C35 C26 C27 OPTION
51 58
59
52 FAN RP4 C FAN RELAY
31