Keeprite AC Unit
Keeprite AC Unit
Performance Series
Product Specifications
Model Size Nominal Min. Circuit Max. Fuse Operating Dimensions Ship / Operating
Number (tons) BTU/hr Ampacity or Breaker height x width/depth in. (mm) Weight lbs. (kg)
25- 5/16 x 23- 1/8
N4A318*KF 1- 1/2 18,000 11.8 20 (643 x 587) 130 / 107 (59 / 49)
25- 5/16 x 23- 1/8
N4A324*KG 2 24,000 14.3 25 (643 x 587) 127 / 107 (58 / 49)
28- 11/16 x 25- 3/4
N4A330*KG 2- 1/2 30,000 16.6 25 (729 x 654) 149 / 126 (68 / 57)
25- 5/16 x 31- 3/16
N4A336*KF 3 36,000 18.1 30 (642 x 792) 151 / 134 (68 / 61)
32- 5/16 x 31- 3/16
N4A342*KN 3- 1/2 42,000 23.5 40 (821 x 792) 218 / 190 (99 / 86)
35- 1/2 x 31- 3/16
N4A348*KG 4 48,000 24.3 40 (901 x 792) 205 / 175 (93 / 79)
28- 11/16 x 31- 3/16
N4A360*KN 5 60,000 29.0 50 (729 x 792) 232 / 199 (106 / 91)
K = 208/230- 1- 60 VOLTAGE
Sales Code
Engineering Revision
Extra Digit
Extra Digit
Check the piston size shipped with the indoor unit to see if it matches the required indoor piston size. If it does not match,
replace the indoor piston with the correct size per the table below.
NOTE: Pistons shipped with outdoor units are only qualified and approved with the above listed fan coils. The piston included
with the FMA4P* and FM(C,U)4P* fan coils are unique to those products and CANNOT be replaced with the piston shipped
with the outdoor unit. Refer to AHRI Directory to check if your combination can use a piston or requires an accessory TXV.
**Sound Rating tested in accordance with AHRI Standard 270- 2008 (not listed with AHRI).
A-Weighted Sound Power Level - Without Sound Shield
Standard TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)
Rating
Model (dBA) 125 250 500 1000 2000 4000 8000
18- F 71 64.0 62.0 63.0 68.0 64.0 62.0 57.0
24- G 74 50.9 60.6 66.4 71.0 65.5 61.1 59.2
30- G 72 54.8 59.3 65.1 68.2 66.4 61.6 57.3
36- F 75 50.5 61.0 64.5 67.0 62.5 60.0 52.5
42- N 78 57.5 65.0 71.0 73.0 70.5 67.5 62.5
48- G 76 55.5 62.9 69.6 71.2 69.5 66.3 59.1
60- N 79 57.5 67.0 72.0 75.0 72.5 68.0 61.0
Note: Tested in accordance with AHRI Standard 270-2008 (not listed in AHRI).
Units are factory charged for 15 ft (4.6 m) of 3/8” liquid line. The factory charge for 3/8” lineset 9 oz. When using other length or
diameter liquid lines, charge adjustments are required per the chart above.
Charging Formula:
[(Lineset oz/ft x total length) – (factory charge for lineset)] = charge adjustment
Example 1: System has 15 ft of line set using existing 1/4“ liquid line. What charge adjustment is required?
Formula: (.27 oz/ft x 15ft) – (9 oz) = (-4.95) oz.
Net result is to remove 4.95 oz of refrigerant from the system
Example 2: System has 45 ft of existing 5/16” liquid line. What is the charge adjustment?
Formula: (.40 oz/ft. x 45ft) – (9 oz.) = 9 oz.
Net result is to add 9 oz of refrigerant to the system
LONG LINE APPLICATIONS
An application is considered Long Line, when the refrigerant level in the system requires the use of accessories to maintain
acceptable refrigerant management for systems reliability. See Accessory Usage Guideline table for required accessories. Defining a
system as long line depends on the liquid line diameter, actual length of the tubing, and vertical separation between the indoor and
outdoor units.
For Air Conditioner systems, the charts below shows when an application requires a TXV and long line accessories due to lineset
length.
AC with R- 410A Refrigerant Long Line Description ft (m) Beyond these lengths, a TXV is required
Total Length Outdoor Unit Above or Below Indoor Unit
TXV required beyond 50 ft. (15.2 m) TXV required beyond 20 ft. (6.1 m)
AC with R- 410A Refrigerant Long Line Description ft (m) (Beyond these lengths, long line accessories are required)
Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor
No accessories needed within al- No accessories needed within
1/4 + TXV 175 (53.3)
lowed lengths allowed lengths
5/16 + TXV 120 (36.6) 50 (15.2) vertical or 120 (36.6) total 120 (36.6)
3/8 + TXV 80 (24.4) 35 (10.7) vertical or 80 (24.4) total 80 (24.4)
Note: See Long Line Guideline for details
R- 410A COOLING CAPACITY LOSS FOR VARIOUS LINE LENGTHS & TUBE DIAMETERS
Cooling Capacity Loss (%) at Total Equivalent Line Length, feet (m)
Acceptable Refer to Long Line Application Guideline to calculate equivalent length
Liquid
Model Vapor Line
Line Sizes
Standard Application Long Line Application (Requires Accessories)
Size
in.(mm) in. (mm) 25’ 50’ 80’ 81’ 100’ 125’ 150’ 175’ 200’ 225’ 250’
(7.6) (15.2) (24.4) (24.7) (30.5) (38.1) (45.7) (53.3) (61) (68.6) (76.2)
1/2 (13) 1 2 3 3 4 6 7 8 9 10 12
18 5/8 (16) 0 0 1 1 1 1 2 2 3 3 3
3/4 (19) 0 0 0 0 0 1 1 1 1 1 1
5/8 (16) 0 1 1 1 2 3 3 4 4 5 6
24 3/4 (19) 0 0 0 0 0 1 1 1 1 1 2
7/8 (22) 0 0 0 0 0 0 0 0 0 0 1
5/8 (16) 1 2 3 3 3 4 5 6 7 8 9
30 3/4 (19) 0 0 1 1 1 1 2 2 2 3 3
7/8 (22) 0 0 0 0 0 1 1 1 1 1 1
5/8 (16) 1 2 4 4 5 6 7 9 10 11 13
36 3/8 (10) 3/4 (19) 0 0 1 1 1 2 2 3 3 4 4
7/8 (22) 0 0 0 0 0 1 1 1 1 2 2
3/4 (19) 0 1 2 2 2 3 4 4 5 6 6
42 7/8 (22) 0 0 1 1 1 1 2 2 2 3 3
1- 1/8 (29) 0 0 0 0 0 0 0 0 0 0 1
3/4 (19) 0 1 2 2 3 4 5 5 6 7 8
48 7/8 (22) 0 0 1 1 1 2 2 2 3 3 4
1- 1/8 (29) 0 0 0 0 0 0 0 0 1 1 1
3/4 (19) 1 2 4 4 5 6 7 9 10 11 12
60 7/8 (22) 0 1 2 2 2 3 4 4 5 5 6
1- 1/8(29) 0 0 0 0 1 1 1 1 1 1 2
Consult the Long Line Application Guideline document before purchasing/installing line sets.
Applications in shaded area may have height restrictions that limit allowable total equivalent length when outdoor unit is below indoor
unit.
Total sensible capacities are based on net capacities. Blower heat has been subtracted.
Sensible capacities shown are based on 800 F (270 C) entering air at the indoor coil. For sensible capacities at other than 800 F (270 C), deduct 835 Btuh (245
kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 800 F (270 C), or add 835 Btuh 245 kW) per 1000 CFM (480 L/S) of indoor coil air per
degree above 800 F (270 C).
Detailed cooling and heating capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240 -2008. If additional tubing length
is required and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur.
System kw is total of indoor and outdoor unit kilowatts.
ACCESSORIES
Used On
Part Number Description Model Size
NASA003CH Crankcase Heater for Scroll Compressor (208/230V) 18, 24, 30, 36
NASA001CH Crankcase Heater for Scroll Compressor (208/230V) 42, 48, 60
NASA003SC Hard Start Kit (Capacitor & Relay) ALL
NASA00201FS Evaporator Freeze Thermostat ALL
NASA403PS Low Pressure Switch, AC, R- 410A ALL
NASA404PS High Pressure Switch, AC or HP, R- 410A ALL
NASA001LS Liquid Line Solenoid Valve, R- 410A ALL
NASA001TD Time Delay Relay, Indoor Blower ALL
NASA00201WS Winter Start Control ALL
NASA001AC Anti- Cycle Timer (5 minute delay) ALL
NASA401LA Low Ambient Kit (Pressure Switch), R- 410A ALL
NASA00201SF Support Feet, 4” (102mm) tall (5 blocks) 18, 24, 30
NASA001SF Support Feet, 4” (102mm) tall (4 blocks) 36, 42, 48, 60
NASA00301SJ Sound Jacket, Compressor 18, 24, 36
NASA00201SJ Sound Jacket, Compressor 30, 42, 48
NASA00101SJ Sound Jacket, Compressor 60
NAEA40501TX TXV Kit, R- 410A - for use with copper or tin fan coils 18, 24
NAEA40601TX TXV Kit, R- 410A - for use with copper or tin fan coils 30, 36, 42
NAEA40701TX TXV Kit, R- 410A - for use with copper or tin fan coils 48, 60
NAEB40501TX TXV Kit, R- 410A - for use with aluminum coils 18, 24
NAEB40601TX TXV Kit, R- 410A - for use with aluminum coils 30, 36, 42
NAEB40701TX TXV Kit, R- 410A - for use with aluminum coils 48, 60