0% found this document useful (0 votes)
7 views1 page

Water Piping P&id

The document is a P&ID (Piping and Instrumentation Diagram) for water piping in a project related to Adani Wilmar Ltd. It includes various components such as valves, tanks, and piping specifications, along with a review and approval section. The drawing is dated May 15, 2023, and emphasizes compliance with contract requirements.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
7 views1 page

Water Piping P&id

The document is a P&ID (Piping and Instrumentation Diagram) for water piping in a project related to Adani Wilmar Ltd. It includes various components such as valves, tanks, and piping specifications, along with a review and approval section. The drawing is dated May 15, 2023, and emphasizes compliance with contract requirements.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

12 11 10 9 8 7 6 5 4 3 2 1

H P & ID FOR WATER PIPING SEP SECTION H

SG

G I
P
G
FLOAT VALVE
2"

EMERGENCY WATER
STORAGE TANK
AV 3
OWT
85 M

DRAIN

DRAIN
50 NB

50 NB
F TI
F
05
N6
50
N4 N3
50 40

N2
40

TI
320

PI
02
TI
330
VF

PI LS
03 380B
TI TI
N1
40
06 07
N5
40

LIC
380A

PT
320A

E PI
330A LI
0340
TI
320
E
FI I
396 BY RTD P

LT TT FY FIC
0340 320 0345
0345
FT
396
PI
TI 05 FCV
361B
PI 345
01
TI FT
305 PI 0345
320A FC

TI
361A
TI
381B PI PI
04A 04
RTD
PI
TT
381B 01A
TI
10

RECDUCER RECDUCER RTD

D CONCENTRIC
125 x 300
CONCENTRIC
125 x 300
LIC
312A
TI
380
PI
TT
380
PI TI D
LI 06 07 08
312B GR

GR
LT
312A PI PT
380 380
LT
312B

VF

FN-380A FN-380B LS PI
312B 382
PI PI
VF
381 383 TI
350A
PI
FT MAKEUP WATER
395
LS
312A TT
RTD
355
350A

TI TI TI
01 02 03 SG

PI
FOOT 350 TK 355
VALVE CHILLED
COOLING TOWER CT-380 WATER TANK

CAPACITY: 400m³/hr PU381 PU382 PU383


C T 6°C C

This review and approval does not relieve supplier / sub contractor from full compliance with purchase
order / contract requirements and also from errors in this drawing / document.

By: Date:
--------------------- ---------------------

Project: Discipline:
----------------------- -----------------------

B B
R1 DRG. CORRECTED 18.5.23 L.B.N.
REV. REVISION TEXT DATE DRAWN CHECKED APPR.
CLIENT M/S ADANI WILMAR LTD

SUPPLIER: A401, EUREKA TOWER,


NEW LINK ROAD, MALAD (W)
MUMBAI :-400 064
TEL.:-22086368 FAX.:-22067131
Email-servotec@bom3.vsnl.net.in

PROJECT
AWL-MANTRALAYAM, A P
A A
TITLE

DATE 15.05.23 DRAWN L.B.N. CHECKED US

SCALE NOT TO SCALE APPROVED


DRAWING NO. 2650622-037-004 R 1
12 11 10 9 8 7 6 5 4 3 2 1