IN JE C TIO N P U M P TE S T S P E C IFIC ATION S 092000-3082
MANUFACTURER M ITSUBISHI INJECTION 0 9 2 0 0 0 -3 0 8 #
PUMP ND-PES6A100I320RND308
ENGINE TYPE S6S-DT
GOVERNOR 190800-6210 (RSV)
VEHICLE TYPE POW ER SHOVEL TIMER —
1 . I NJ E C TI O N TI M I NG
Rotation : Clockwise viewed from drive side Pre - stroke :3.3 ± 0.05 m m
Injection Order : 1- 5- 3- 6- 2- 4 Tappet Clearance : More than 0.2 mm
Injection Interval : 60° ± 30' Locked Timing Location : —
2 . TE S T CO NDI TI O NS
2
Nozzle : 093400-0540 (DN12SD12A) Feed Pressure : 2.0 kg/cm
2
Nozzle Opening Pressure : 177.5 ± 2.5 kg/cm High Pressure Pipe : Ø2 X Ø6 X 600 mm
Test Oil : SAE J967 (ISO4113) Fuel Temperature : 40 - 45°C (104 - 113°F)
Overflow valve opening : 1.6 kg/cm 2
3 . A DJ US TME NT O F D E LI V E RY Q UA NTI TY
Pump Speed Rack Travel Number of Delivery Quantity Max. Spread in
Remarks
(rpm) (mm ) Strokes (cc/cyl.) Delivery (cc)
480 7.3 500 2.3 ± 1.0 1.0
1050 11.3 200 14.2 ± 0.4 0.7
4 . A DJ US TME NT O F G O V E R NO R
Control Speed Range : 480 - 1050 rpm X = approx. 2.25
092000-3082
5. ADJUSTM ENT OF BOOST COMPENSATOR — : Not applicable
Lever Position Pump Speed Positive Pr essur e Rack Tr avel Delivery Quantity
Remar ks
(deg) (r pm) (mmHg) (mm) (cc/200st)
— — — — — —
6. ADJUSTMENT OF PUM P W ITH GOVERNOR OPERATION
Lever Position Pump Speed Positive Pr essur e Number of Delivery Quantity
Remar ks
(deg) (r pm) (mmHg) Str okes (cc/cyl.)
Full 1050 — 1000 71.0 ± 2.0
7. ADJUSTMENT OF TIM ER — : Not applicable
Pump Speed
—
(r pm)
A dvance A ngle —
(deg)
8. RACK SENSOR OUTPUT VOLTAGE CHECK — : Not applicable
Lever Position Pump Speed Rack Tr avel Output V oltage
Remar ks
(deg) (r pm) (mm) (V )
— — — — —
A djust the thickness of shims w ithin the range of 0 - 1.0 mm so that the output voltage of the r ack sensor becomes as
specified in the table below .
092000-3082
NO TE :
1. The 1st cylinder is on the drive side.
2. Adjusting Lever Angle (fig. 1)
Setting position 40° to be at vertical position.
3. Stop Lever Operation
Rack travel must be less than 4.0 mm when the stop lever is pulled at pump speed 1050 rpm
in full lever position, with setting its position 26.0 away from the tail end of governor. fig. 1
4. After solenoid assembling, practice operation test as following.
(Tim e for turning on electricity is less than 10 seconds.)
(1) Voltage at test : 20 V (D.C.)
(2) At turning on electricity, stop lever position
(3) M ust be within L dimension. (fig. 2 L dim ension = 25.2 ± 0.8 m m)
fig. 2