0% found this document useful (0 votes)
79 views4 pages

Inciner8 I8-1000G Technical Datasheet

The i8-1000G is Inciner8's flagship incinerator model, designed for efficient waste disposal with customizable features and low emissions. It utilizes advanced Coretex insulation, smartpanel technology for remote monitoring, and has a high burn rate suitable for various waste types. The machine is compliant with ISO 9001 standards and is widely used across multiple industries for effective waste management.

Uploaded by

limjeorge
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
79 views4 pages

Inciner8 I8-1000G Technical Datasheet

The i8-1000G is Inciner8's flagship incinerator model, designed for efficient waste disposal with customizable features and low emissions. It utilizes advanced Coretex insulation, smartpanel technology for remote monitoring, and has a high burn rate suitable for various waste types. The machine is compliant with ISO 9001 standards and is widely used across multiple industries for effective waste management.

Uploaded by

limjeorge
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

WWW.INCINER8.

COM

INCINER8 I8-1000G TECHNICAL


DATASHEET
TECHNICAL INTRODUCTION model: i8-1000G

The flagship model within our general lineup is the i8-1000G. It took over three years to develop and is at the forefront
of combustion technology, offering impressive burn rates and large batch sizes while still achieving some of the lowest
emissions in its class. The i8-1000G can be customised with viewing windows, external cladding and automatic loading
to provide an effective and sustainable waste disposal solution for many different types of industries with large volumes of
waste such as RDF, SRF and MSW. It also has the benefit of being fitted with our smartpanel technology allowing operators
to remotely monitor performance and see reports from anywhere in the world. Unless specificed this model uses our NX PLC
range of control panels.

LOAD CAPACITY
Inciner8 uses four main size guides within our comprehensive range to differentiate our models, from S to XL. This allows us to provide
you with a machine that perfectly fits your needs and your waste stream.

CORETEX INSULATION
Coretex insulation - Triple insulation Coretex technology uses a combination of high-density insulation board, custom refractory concrete
and thick steel to deliver the ultimate incineration insulation.

TOP LOAD
Top loading allows the waste to be dumped in from above making it easy to access for trucks and machinery. It also allows additional
extras such as bin tippers and autoloaders to be used within the operation to improve efficiency and incineration times.

SMARTPANEL REMOTE MONITORING


Smartpanel remote monitoring is an optional feature that allows users to access the control panel remotely, away from the incinerator.
This allows access and technical support from anywhere in the world, allowing data and controls to be viewed by who needs it the most.

HYDRAULIC DOOR
We manufacture our incinerators from heavy-duty steel, hydraulic doors are fitted to some of our larger models to make it easy and
effortless to open and close the chamber doors via the control panel making light work of continuous loading.

Designed and manufactured in Britain to ISO 9001 accredited quality assurance standards. Our machines are widely used
across a wide range of sectors, in the UK and around the world, including municipal waste management, manufacturing,
mining, and hospitality, as well as tackling serious waste management challenges, including controlled drug disposal,
humanitarian response and marine waste.

i8-1000G FEATURES
Fully insulated chamber to retain heat and improve combustion
Rapid, complete and efficient waste disposal
Patented safety handle for easy access to chamber
High quality refractory lining and insulation
Easy to use CE7 control panel
Programmable temperature control for complete combustion
Secondary chamber* with 2 second retention time
Fast pre-heat and continual high temperature performance
Low energy consumption levels

* Our primary and secondary combustion chambers are constructed from superior grade steel and state-of-the-art monolithic concrete refractory with a unique concave design to prevent
cold spots and maximize heat retention during the start-up and combustion processes. When the secondary burner is activated a flame curtain is created which ensures the thermal
decomposition of smoke and harmful emissions to produce a clean, odourless vapour exiting the chimney stack.

For additional information, or to speak Call Email


to one of our expert team: +44 (0) 1704 884020 sales@inciner8.com www.inciner8.com
TECHNICAL BREAKDOWN model: i8-1000G

HT THERMOCOUPLES
Independent control of primary and secondary temperatures
via the control panel.
SECONDARY CHAMBER
Retains and re-burns the exhaust gases for minimum of 2
seconds at 850°C.

CHIMNEY STACK

Stainless steel stack for longevity. Fitted with a velocity cowl


as standard.
PRIMARY CHAMBER
Chamber designed for maximum air flow and circulation
which in turn improves efficiency and total burn time.
SAFE USE HANDLES
Easy to open and close loading door. Designed to increase
operator safety.
COOL TOUCH CLADDING
Steel cladding to reduce risk of infection and increase “Photos are for illustration purposes only. Specification (including paint colours) are
longevity of system. subject to change without notice and do not affect the performance of the machine.”

LOW NOX BURNERS


These are some of the cleanest, most efficient burners
available today. These can be supplied as gas or oil fired.

HOW INCINERATION WORKS


Incineration is a waste treatment process that utilizes the combustion of organic substances contained within materials to convert waste into ash,
heat and flue gas. The ash residue is mostly formed by inorganic constituents of the waste which may take the form of solid lumps or powder.

Heat produced by the incineration process can be fed into a heat exchanger to produce hot water or air which can be used for cleaning or heating
purposes. The remaining flue gases are passed through pollution control devices in the form of a secondary combustion chamber or additional filtration
(if required) and then expelled to the atmosphere.

APPLICATIONS
Our versatile range of medical incinerators are designed for a wide range of waste types. This particular model benefits from a front loading design
and very simple operation process. Ideal as a stand-alone machine where limited staff are available to operate.

Plastics & packaging


Camp waste
Domestic waste
Industrial Waste
Hotels & Resorts
Mining Operations
Wood/Construction
Document Waste
Emergency/Refugee Camps

For additional information, or to speak Call Email


to one of our expert team: +44 (0) 1704 884020 sales@inciner8.com www.inciner8.com
TECHNICAL SPECIFICATION model: i8-1000G

OPERATIONAL SPEC PHYSICAL SPEC

Combustion Chamber Volume (m3) 8.70m3 Assembled L/W/H (mm) 6900 x 2900 x 6260
Burn Rate (Kg p/h) Up to 600Kg Assembled Weight (Kg) 24000kg
Fuel Consumption (Ltrs p/hour) 40-50 ltrs Door Size (mm) 4000 x 1500mm
Time To Temp 45-60 mins Thermocouples (Qty) 7
Gas retention Time (Seconds) 2 secs Steel Thickness (mm) 4mm
Loading Method Top Load No. Of Burners 7
Fuel Options Light Oil or Gas/LPG Refractory Composition Coretex
Electricity Supply 110v or 230v Operating Footprint 58.41m2
Control Panel (IP Rating) IP55 Cool Touch Cladding Yes
Heat Recovery Yes Viewing Portal No
Auto Ash Removal Yes Tertiary Air Fan No
Auto Loader Compatible Yes *The above figures are guidelines ONLY.

Remote Monitoring Yes


Ash Residue 3-5%
Recommended Operational Temperature 850oC

Ecoflam burners are renowned worldwide for providing high efficiency and reliable operation with significant energy savings and feature extreme ease
of installation, maintenance and flexible boiler-burner matching. This model is fitted with low NOx burners as standard to ensure a complete and clean
burn cycle, this reduces installation time and maintenance.

ECOFLAM BURNER SPECIFICATIONS

PARAMETER (1/2 HR AV) LIMITS MEASURED*


- MAX 1-12 have electrical frequency 50-60 Hz
Total Dust 30mg/m3 12mg/m3 - High efficiency fan ventilation system (HPV)
Sulphur Dioxide 200mg/m3 2.4mg/m3 - Low NOx version class 3 with yellow flame
- Designed in compliance with current regulations
Nitrogen Dioxide 400mg/m3 60mg/m3 - ISO 9001 and VISION 2000 certification
- All burners are fire tested
Carbon Monoxide 100mg/m3 78.3mg/m3 NB: picture for illustration purposes only
*The above figures are guidelines ONLY.

AVERAGE EMISSIONS / EU STANDARDS


All of our secondary combustion chambers are designed to operate at 850 - 1200°C to re-burn waste gases which prevents smoke, odours and
harmful emissions. Dioxins and similar gaseous components are destroyed by a combination of homogeneous high temperatures, excess oxygen
levels and sufficient gas residence time in the secondary chamber which our incinerators achieve.

Emissions are largely a product of the waste materials therefore care should be taken when selecting the most appropriate method of pollution
control to ensure compliance with your local emissions standards, please discuss this with our sales team if you aren’t sure.

CALL INCINER8 AND START BUILDING SOLUTIONS


TO YOUR WASTE CHALLENGES TODAY!
+44 (0) 1704 884020 OR
EMAIL SALES@INCINER8.COM

For additional information, or to speak Call Email


to one of our expert team: +44 (0) 1704 884020 sales@inciner8.com www.inciner8.com

You might also like