0% found this document useful (0 votes)
101 views8 pages

Ditee Sword 500 Icp-Oes

The DITEE SWORD 500 is an advanced Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) developed by DITEE Scientific, leveraging over 60 years of expertise in spectroscopy. It features a Rowland Circle optical system, cutting-edge CMOS detectors, and offers low operating costs, making it suitable for various applications including energy, metallurgy, and environmental analysis. The instrument can detect approximately 70 elements with high sensitivity and stability, and is supported by a professional technical team for maintenance and service.

Uploaded by

Marcin Kudelski
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
101 views8 pages

Ditee Sword 500 Icp-Oes

The DITEE SWORD 500 is an advanced Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) developed by DITEE Scientific, leveraging over 60 years of expertise in spectroscopy. It features a Rowland Circle optical system, cutting-edge CMOS detectors, and offers low operating costs, making it suitable for various applications including energy, metallurgy, and environmental analysis. The instrument can detect approximately 70 elements with high sensitivity and stability, and is supported by a professional technical team for maintenance and service.

Uploaded by

Marcin Kudelski
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

DITEE SWORD 500

Induc vely Coupled Plasma


Op cal Emission Spectrometer (ICP-OES)
Reliable Elemental Analysis

DITEE Scien fic
Since 1960
Inherited from the first genera on of
spectrometer experts in China

The DlTEE SWORD 500 Induc vely Coupled Plasma Op cal Emission Spectrometer (ICP-OES) is the result of the
con nuous efforts in research and development by the spectroscopy experts at the Guangdong Academy of
Sciences (GDAS) for over 60 years. This advanced instrument is equipped with a Rowland Circle op cal system
designed to minimize matrix interference, along with cu ng-edge CMOS detectors for full-spectrum collec on. It
offers excellent stability, low limit of detec on, rapid analysis, and low opera ng costs.

The DlTEE SWORD 500 can be op onally equipped with a laser abla on solid sampling system, offering a unique and
cost-effec ve LA-ICP (Laser Abla on Induc vely Coupled Plasma) spectrometer.

The DlTEE SWORD 500 ICP-OES is widely used for sample analysis across various applica on fields, including new
energy, nuclear industry, metallurgy, rare earth and magne c materials, geology, environment, petroleum, new
chemical materials, agriculture, food, healthcare, biology, marine, and water quality. This instrument can quickly
and accurately detect approximately 70 elements, ranging from trace to major concentra ons.
Working Principle

Rowland Circle

Core Advantages

Superior Performance
Excellent spectral resolu on and op cal detec on
capabili es
Reliable wavelength stability
Stable power output from the plasma generator
ensures accurate detec on results

Extremely Low Opera ng Costs


No need to blow away the frost, ready to use
when powered on

Lower Environmental Requirements


Built-in op cal chamber temperature control system,
patented built-in cooling system, suitable for various
industrial usage environment requirements
Major Innova ve Technologies

Full First-Order Spectral Line Rowland Chamber


The 2700 L/mm ruled Rowland gra ng u lizes first-order spectral lines for
measurement, thereby elimina ng interference from higher-order spectral
lines
Single-stage spectroscopy and imaging eliminate the need for prism-based
secondary dispersion and mul ple mirrors, significantly reducing light
energy loss

High Signal-to-Noise Ra o Linear Array CMOS Detectors


Cu ng-edge linear array CMOS detectors exhibits excellent sensi vity in the
vacuum ultraviolet range (below 200 nm) and delivers a high signal-to-noise
ra o without requiring refrigera on

Auto-Tuning Plasma
Con nuously adjustable power
Power is automa cally tuned based on load condi ons to maintain stable
output
Integrated automa c temperature and flame monitoring

Ver cal Torch, Radially Viewed


Minimize sample deposi on, crystalliza on, and blockage, thereby greatly
improving the carrying capacity of high matrix samples

Patented Built-in Cooling Solu on


The built-in industrial coolant circula on system offers heat dissipa on
efficiency significantly higher than that of air cooling systems, minimizing
the risk of system failures due to cooling issues
The integrated closed design removes the need for external chillers and
water changes, effec vely preven ng problems such as scale buildup, algae
growth, and freezing

35 ˫ Constant Temperature Op cal System


Fully sealed light chamber eliminates the need for high-flow argon gas purg-
ing
Employs cu ng-edge linear array CMOS detectors to achieve high
signal-to-noise ra os without refrigera on, ensuring a frost-free opera on
without the need for argon gas blowing
The integrated op cal system features an automa c temperature control
device that maintains a constant temperature of 35 , minimizing the
requirements on external environmental condi ons and ensuring stable
detec on in varying ambient temperatures
Technical Specifica ons
Paschen-Runge, Rowland Circle op cal structure, thermally stabilized to 35°C ± 0.5°C
Rowland Circle focal length: 500 mm; holographic concave gra ng: 2700L/mm
Op cal resolu on: 0.006nm (Constant)
Wavelength range: 175-870nm
24 pieces of high-performance CCD detectors, 2048 pixels per array
Ver cal torch, radically viewed
Dynamic range: >10 9
Stability: Repeatability RSD≤0.5%(1mg/L)(n=10)
Short-term stability RSD≤0.5% (500×LOD)
Long-term stability RSD≤1.0% (500×LOD)
Op cal System
500mm focal length Rowland Circle, maximum spectral resolu on of 0.006nm (constant)

The op cal design eliminates mul -level spectrum interference


(SBUJOH
from the sample matrix, reducing matrix interference by approxi-
mately 70 mes compared to common echelle gra ng op cal
systems (using iron-based samples as an example)

3PXMBOE$JSDMF

&OUSBODF4MJU

%FUFDUPS

Echelle Gra ng Op cal System Rowland Circle Op cal System

Plasma
Advantages of ver cal torch, radially viewed:
No torch burnout
Reduced matrix interference
Decreased sample system rinse me
Lower experimental costs
Faster analysis speed
Wide detec on concentra on range: from percent concentra ons to sub-ppb

Central Channel

View Zone

Height of Light Collec on

Inductor Coil

Preheat Zone

Sample Inlet
Plasma Generator
Features of the plasma generator:

Externally excited all-solid-state RF generator

Frequency: 27.12 MHz

Power: 750-1500 W

Power stability: <0.1%

Patented built-in cooling system

Fully automa c control with con nuously adjustable power

Power feedback self-tuning and temperature protec on func ons

Sample Injec on System


Three-channel peristal c pump: 0-70 rpm, con nuously adjustable

All gas flows controlled by so ware

*Mass flow meters and solenoid valves for gas distribu on control
*Con nuously adjustable cooling gas, auxiliary gas, and nebulizer gas
*Op onal separate oxygen or addi onal gas flow controllers
*So ware displays gas flow rates

Op onal laser abla on solid sampling system (LA-ICP spectroscopy),


offering the industry’s only low-cost LA-ICP solu on

*No addi onal water cooling or power drive equipment required

* U lizes a 1064nm diode-pumped pulsed laser with an adjustable


opera ng frequency of 1-10Hz, offering excellent energy stability
and a 10 mes higher energy u liza on efficiency compared to UV
lasers

* Suitable for various solid samples, including alloys, ores, soils,


polymers, electrode materials, and more
About DITEE Scien fic

DITEE Scien fic was established in 2020, and is an innova ve technology enterprise integra ng R&D,
produc on, sales, and maintenance. The research experts at DITEE Scien fic come from the Guangdong
Academy of Sciences and have been engaged in the development of spectroscopic instruments since
the 1960s. Currently, DITEE Scien fic is equipped with a team of professionals who have long been
involved in the R&D of analy cal instruments, instrument produc on, and analy cal applica ons. We
possess strong problem-solving capabili es and are commi ed to mee ng the ever-changing customer
demands in the market, striving to create high-quality products and services.

Research and Development History


In the 1960s, the first genera on of domes c spectroscopy experts start their research at the Guang-
dong Academy of Sciences.
Since 2020, several key patents based on atomic emission spectroscopy have been obtained.
In 2014, started research of OA800 Oil Analysis Spectrometer (RDE-OES).
In 2015, the Guangdong Provincial Department of Finance support the research of RDE-OES.
In 2018, the demo of the RDE-OES passed third-party tes ng.
In 2020, DITEE Scien fic established.
In 2023, obtained the cer fica on for high-tech enterprises.
In 2024, launched the ICP-OES and the MP-AES.

Quality Management System Cer fica on: ISO 9001: 2015, NOA2208630
Environmental Management System Cer fica on: ISO 14001: 2015, NOA2208629
Occupa onal Health and Safety Management System Cer fica on: ISO 45001: 2018, NOA2208628

Professional technical support and excellent a er-sales service


Users need to ensure that the instruments operate normally at all mes.
DITEE Scien fic has a team of experienced engineers who provide performance assurance service plans
for every instrument. Professional engineers offer high-value customized services to ensure the normal
opera on and prolong the lifespan of the instruments, including but not limited to preven ve maintenance,
applica on method establishment, professional consul ng, and customized training.
DITEE Scien fic provides users with lifelong services for spare parts, consumables, repair and maintenance,
and technical support.

ization for Sta


an n
rg
O

da
International

rdiz

www.rogetscien fic.com
ation

9001

Guangdong DITEE Scien fic & Technical Co., Ltd.


Room 1, 11th Floor, Block C, Foshan Na onal Torch Innova on Pioneering Park, No.13
Huabao South Road, Chancheng District, Foshan City, China
+86-757-83277860