YY LSZH Control Cable NR/OZ Numbered Cores: Tel: 01543 422477 Fax: 01543 422420

The YY LSZH control cable is designed for fixed installation in dry and moist rooms, with outdoor use prohibited. It features low fire load, low smoke emission, and reduced fire propagation, complying with various international standards. The document provides detailed specifications, including voltage ratings, temperature ranges, and various configurations of cores and sizes.

Uploaded by

M. Fak
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
17 views1 page

YY LSZH Control Cable NR/OZ Numbered Cores: Tel: 01543 422477 Fax: 01543 422420

The YY LSZH control cable is designed for fixed installation in dry and moist rooms, with outdoor use prohibited. It features low fire load, low smoke emission, and reduced fire propagation, complying with various international standards. The document provides detailed specifications, including voltage ratings, temperature ranges, and various configurations of cores and sizes.

Uploaded by

M. Fak
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

YY LSZH control cable

NR/OZ numbered cores


Tel: 01543 422477 Fax: 01543 422420

Suitable for fixed installation in dry and Construction:


moist rooms. Outdoor installation not
permitted. bare copper conductor

Pronounced advantages when core insulation; halogen-free type TI6


compared to a PVC control cable: according to HD21.14 SI annex A

- low fire load cores twisted in layers

- low smoke emission grey outer sheath; halogen-free type TM7


according to HD21.14 S annex B
- reduced fire propagation.

Voltage: 300/500V operating 3000V test


Temperature: - 25° C to + 70° C flexible - 40° C to + 70° C static
Bend Radius 15 x O/D mm
Stranding: to DIN-VDE 0295 K5 & CEI 20-29 class 5
NR number coded according to VDE 0250
OZ number coded without earth (green/yellow)
test and control: according to quality systems certificate ISO 9002 CSQ-IMQ (EQ-NET)
self extinguishing: according to test method B IEC 60332-1
flame retardant: according to IEC 60 332.3

No of Area O/D Kg per No of Area O/D Kg per No of Area O/D Kg per No of Area O/D Kg per
cores mm² mm 100m cores mm² mm 100m cores mm² mm 100m cores mm² mm 100m
2 0,5 5.4 4 3 1 6,2 6,3 2 2,5 8,1 10,6 4 6 13,1 35,5
3 0,5 5,9 4,7 4 1 6,9 8 3 2,5 8,7 13,2 5 6 14,5 43,8
4 0,5 6,5 6,7 5 1 7,8 9,9 4 2,5 9,8 17
5 0,5 7,1 8,3 7 1 8,5 12,7 5 2,5 10,7 20,5 4 10 16,3 57,4
7 0,5 7,7 10,2 12 1 11,3 21,9 7 2,5 11,8 26,6
12 0,5 10,3 17,6 18 1 13,5 31 12 2,5 15,6 44,5 4 16 21,4 94
18 0,5 12,3 25,4 25 1 15,4 42 16 2,5 17,6 57,9
25 0,5 14,6 35,5 41 1 20,2 70,8 18 2,5 18,6 64,1 3 35 26,8 147,3
4 35 28 175,7
2 0,75 5,6 5,3 2 1,5 6,5 6,7 3 4 10,4 20,2
3 0,75 6,2 5,5 3 1,5 6,8 8,2 4 4 11,6 25,8
4 0,75 6,9 5,7 4 1,5 7,6 10,3 5 4 12,7 31,3
5 0,75 7,4 6,6 5 1,5 8,4 12,6
7 0,75 8,4 8,5 7 1,5 9,2 16,2
12 0,75 10,6 13,3 12 1,5 12,4 28
18 0,75 12,6 24,5 18 1,5 14,7 40,2
25 0,75 14,8 35,2 25 1,5 17,3 55,4

These cables are also referred to as: Please note:


LSF may mean modified PVC which can give
 LSZH (Low Smoke Zero Halogen) off up to 18% HCI emissions. Whereas the
 LSOH (Low Smoke Zero Halogen) term Zero Halogen ensures that the cables
 LSF (Low Smoke and Fume) give off less than 0.5% HCI emissions. Please
 OHLS (Zero Halogen Low Smoke) ask if you have a specific requirement.