Plumbing

The document outlines plumbing general notes, symbols, and fixture schedules for a construction project, ensuring compliance with the 2020 Florida Building Code and local ordinances. It details the specifications for various plumbing fixtures, materials, and installation practices, emphasizing the need for licensed contractors and proper coordination with other trades. Additionally, it includes requirements for testing, sterilization, and insulation of piping systems to ensure safety and functionality.

Uploaded by

ANSAR HABIB
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
65 views7 pages

Plumbing

The document outlines plumbing general notes, symbols, and fixture schedules for a construction project, ensuring compliance with the 2020 Florida Building Code and local ordinances. It details the specifications for various plumbing fixtures, materials, and installation practices, emphasizing the need for licensed contractors and proper coordination with other trades. Additionally, it includes requirements for testing, sterilization, and insulation of piping systems to ensure safety and functionality.

Uploaded by

ANSAR HABIB
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

PLUMBING GENERAL NOTES:

PLUMBING SYMBOLS PLUMBING FIXTURE SCHEDULE


1. ALL WORKMANSHIP AND MATERIAL SHALL BE IN STRICT ACCORDANCE WITH THE 2020 FBC, 22. NO COMBUSTIBLE MATERIAL SHALL BE USED IN MECHANICAL ROOMS OR IN CEILING
NAME FIXTURE TYPE MANUFACTURE & MODEL# ACCESSORIES ARCHITECT:
& ABBREVIATIONS APPLICABLE LOCAL CODES, RULES AND ORDINANCES. SPACES WHERE USED AS RETURN AIR PLENUMS.
Bermello Ajamil & Partners
WC-1 AMERICAN STANDARD FLUSH VALVE # 6065.121.002 2. CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY FAMILIARIZE HIMSELF WITH 23. NO WATER, SANITARY OR DRAINAGE PIPING PERMITTED IN ELECTRICAL OR ELEVATOR
WATER CLOSET BATTERY SENSOR OPERATED EQUIPMENT ROOMS.; WATER STUBBED THRU FOR ELECTRICAL GROUND & SPRINKLER 4711 South LeJeune Road
(ADA) (MODEL # 2257.101 AFWALL) ALL EXISTING CONDITIONS.
(0.128GPM) HEAD AND PIPE WITH CONTROL VALVE AS APPROVED BY LOCAL BUILDING AND FIRE Coral Gables, FL 33146
3. ALL MATERIAL SHALL BE NEW AND OF AN AMERICAN MANUFACTURER. DEPARTMENTS. P: 305.859.2050
HWS HOT WATER PIPE HWS
WALL HUNG AMERICAN STANDARD AMERICAN STANDARD MODEL #T6220 4. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR IN A FIRST
CWS COLD WATER PIPE CWS L-1 24. ALL STORM DRAINAGE AND SANITARY PIPING 4" AND LARGER WITH OFFSETS MEP ENGINEER:
LAVATORY (LUCERNE WALL-HUNG SINK) BOARDWALK WIDESPREAD BATHROOM FAUCET WITH CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE.
(ADA)
HWR HOT WATER RECIRCULATING HWR (ADA) (MODEL # 0356915) METAL POP-UP DRAIN ASSEMBLY.
5. ALL EXCAVATION AND BACKFILL AS REQUIRED FOR THIS PHASE OF CONSTRUCTION
GREATER THAN 45° SHALL HAVE SWAY BRACING AT DIRECTION CHANGES.
Hammond & Associates, Inc
25. ALL FIRE MAINS, HOT & COLD WATER PIPES, HOT WATER RETURN PIPING, STORM 499 NW 70th Avenue, Suite 201
WATER HAMMER ARRESTOR WHA SHALL BE A PART OF THIS CONTRACT. DRAIN AND CONDENSATE PIPING AND GAS PIPING SHALL HAVE IDENTIFICATION Plantation, FL 33317
CHECK VALVE CV 6. REQUIRED INSURANCE SHALL BE PROVIDED BY THE CONTRACTOR FOR PROTECTION & FLOW DIRECTIONS BANDS.
MS-1 AMERICAN STANDARD(AKRON AKRON WALL MOUNTED CAST IRON UTILITY SINK P: 954.327.7111
UTILITY SINK AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF WORK.
HOSE BIBB W/ VACUUM BREAKER & (AKRON SERVICE SINK) WITH 24" LENGTH 26. THIS PROJECT HAS BOOK TYPE SPECIFICATIONS. THE PLUMBING SECTIONS
SHUT-OFF VALVE MODEL # 7695008.020
STRUCTURAL ENGINEER:
7. CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, INSPECTION & TESTS. OF THESE DRAWINGS AND THE SPECIFICATIONS MUST BE READ IN CONJUNCTION
GATE VALVE (SHUT-OFF VALVE) ASHRAE 18 TESTING WITH EACH OTHER PRIOR TO BID AND CONTRUCTION OF THIS PROJECT. ALL
S & F Engineers, Inc
S.V EWC-1 ELECTRIC WATER COOLER ELKAY 8. DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE FOR THE EXACT LOCATION OF
(ADA) BI - LEVEL (MODEL # VRCTL8WSK) VANDAL- RESISTANT BOTTLE FILLING STATION ARE CONSIDERED ONE DOCUMENT. 2925 W. Cypress Creek Rd., Suite 200
GREASE WASTE PIPE GW REMOTE CHILLER: MODEL HCR8, 8GPH FIXTURES, PIPING, EQUIPMENT, ETC.
Fort Lauderdale, FL 33309
NON- FILTER REFRIGERATED STAINLESS 27. CONTRACTOR SHALL KEEP A SET OF AS BUILTS DWG. ON THE JOB SITE AT ALL
SANITARY PIPE SAN 9. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE P:954.938.0020
TIMES AND DELIVER A SET OF UP TO DATE AS-BUILTS TO THE ENGINEER &
CD CONDENSATE DRAIN PIPE CD WITH THE PROGRESS OF CONSTRUCTION. REPORT ANY DISCREPANCY TO ENGINEER/
OWNER AT THE COMPLETION OF THE PROJECT. GEOTECHNICAL ENGINEER:
ARCHITECT PRIOR TO BEGINNING CONSTRUCTION.
VENT PIPE
CO CLEAN-OUT
JAY R. SMITH
(4020 SERIES) 28. AS SOON AS THE WATER PIPING HAS BEEN THOROUGHLY FLUSHED OUT, STERILIZE GCES Engineering
P&T 10. VERIFY LOCATION, SIZE, INVERTS OF ALL EXISTING UTILITIES PRIOR TO BEGINNING OF
TEMPERATURE & PRESSURE RELIEF P&T
CONSTRUCTION. ADVICE ENGINEER OF ANY DISCREPANCIES OR POSSIBLE CHANGES.
THE NEW WATER PIPING LINES BY INTRODUCING IN THEM A SOLUTION OF CALCIUM Services, LLC.
DP DRAIN PAN DP HYPOCHOLORITE OR CHLORIDE OF LIME. OPEN AND CLOSE ALL NEW VALVES WHILE
FCO FLOOR CLEAN-OUT JAY R. SMITH
11. WATER PIPING ABOVE GRADE SHALL BE TYPE "L" COPPER.
10860 NW 138th Street, Unit 4,
(4020 SERIES) SYSTEM IS BEING CHLORINATED. AFTER THE STERILIZING AGENT HAS BEEN APPLIED
FLOOR DRAIN WITH 1/2" TRAP PRIMER ALL UNDERGROUND WATER PIPING SHALL BE TYPE "K" COPPER.
Hialeah Gardens, FL 33018
FOR 24 HOURS, TEST FOR RESIDUAL CHLORINE AT THE ENDS OF LINES. IF LESS
WATER CLOSET WC A.O.SMITH P: 305.964.0669
12. SOIL, WASTE, VENT PIPING SHALL BE CAST IRON NO HUB 301-72 ABOVE GRADE AND THAN 10 PARTS PER MILLION IS INDICATED, REPEAT THE PROCESS. WHEN TESTS
EWH-2 ELECTRIC WATER HEATER DURA POWER SERIES COST ESTIMATOR:
VENT THRU ROOF VTR (120V, 2.5KW, 1∅) SCHEDULE 40 PVC BELOW GRADE. MECHANICAL JOINTS W/ S.S. CLAMPS BELOW SHOW AT LEAST 10 PARTS PER MILLION OF RESIDUAL CHLORINE, FLUSH OUT THE
DEL- 20 GALLON
LAVATORY LAV GRADE. SYSTEM UNTIL ALL TRACES OF THE CHEMICAL USED ARE REMOVED. MAKE Program Control, Inc
LITTLE GIANT NECESSARY CONNECTIONS TO STERILIZE PIPING. 3150 SW 38th Avenue
JANITOR'S SINK JS ESP-1 ELEVATOR SUMP PUMP AIR CONDITIONING CONDENSATE DRAIN PIPING SHALL BE COPPER TYPE L ASTM 8B88.
MODEL# OS3-6E-1 115V, 60HZ, 1/3HP 13. AFTER STERILIZATION HAS BEEN ACCOMPLISHED INITIATE A BACTERIOLOGICAL
SINK SK ABOVE GRADE & SCH. 40 PVC BELOW GRADE.
Suite 1304, Miami, FL 33146
TEST PERFORMED BY AN APPROVED TESTING LABORATORY. WATER SHALL BE P: 786.229.4416
MOP SINK MS JAY R. SMITH POLISHED WALL FAUCET WITH HOSE 14. PIPING INSULATION: DRAWN FROM THE SYSTEM AT A POINT FURTHEST FROM THE WATER ENTRANCE
HB 3/4" HOSE BIBB SURVEYOR:
FLOOR SINK FS MODEL # 5673(-CR) CONNECTION INSULATE ALL CONDENSATE PIPING. DO NOT INSULATE CONDENSATE PIPING BELOW GRADE. TO THE BUILDING. A CERTIFIED TEST REPORT OF THESE TESTS RESULTS

FLOOR DRAIN FD 14A. HOT WATER PIPING:


INDICATING SATISFACTORY COLIFORM COUNT, COLOR AND CHLORINE RESIDUAL Premiere Design Solutions
SHALL BE PRESENTED TO THE ARCHITECT AND OWNER WHEN THE WATER
1/2" TO 1" USE 1" PREFORMED FIBERGLASS PIPE INSULATION W/ FACTORY JACKET. 11606 City Hall Promenade, Ste 200,
ELECTRIC WATER COOLER EWC FIXTURE TYPE WATER PIPE SIZE NOMINAL SAN. SIZE MAX. FLOW RATES 1 1/4" TO 2" USE 1 1/2" PREFORMED FIBERGLASS PIPE INSULATION W/ FACTORY JACKET.
SUPPLY PIPING SYSTEM IS SUBSTANTIALLY COMPLETED DURING CONSTRUCTION.
Miramar, FL 33025
ANOTHER SIMILAR TEST SHALL BE PERFORMED AT THE TIME OF ISSUANCE OF
ELECTRIC WATER HEATER EWH 2 1/2" TO 6" USE 2" PREFORMED FIBERGLASS PIPE INSULATION W/ FACTORY JACKET. P: 954.237.7850
WATER CLOSET (FLUSH VALVE) 1" 3" 1.28 GPF THE CERTIFICATE OF OCCUPANCY WITH ANOTHER CERTIFIED TEST REPORT
KITCHEN SINK KS
14B. HORIZONTAL STORM DRAIN WITH IN CONDITION SPACES USE 1" PERFORMED FIBERGLASS PRESENTED TO THE ARCHITECT AND OWNER AT THAT TIME. OWNER:
ABOVE FINISH FLOOR A.F.F. LAVATORY 1/2" 1 1/4" 0.5 GPM
BELOW FINISH FLOOR B.F.F.
14C. PIPE INSULATION WITH FACTORY JACKET. 29. APPLY A WATER PRESSURE TEST TO ALL PARTS OF THE WATER PIPING SYSTEM
NOT LESS THAN 150 PSIG OR 1.25 TIMES THE SYSTEM WORKING PRESSURE
PORT EVERGLADES
FLOOR CLEANOUT FCO JANITORIAL SINK 1/2" 3" 2.0 GPM 14D. CONDENSATE PIPING INSULATION USE 1" ARMAFLEX.
(WHICHEVER IS GREATER), FOR A PERIOD OF 4 HOURS. REPAIR ANY LEAKS. DEPARTMENT OF
CLEANOUT TO GRADE CTG
ELECTRIC WATER COOLER 1/2" 1 1/4" 0.5 GPM
14E. EXHAUST PIPING USE 3" THICK CALCIUM SILICATE BLOCK INSULATION WITH 1200
F. STEVENS CLASS CLOTH WRAP.
30. APPLY A WATER TEST TO ALL PARTS OF THE SANITARY AND STORM DRAINAGE BROWARD COUNTY
WALL CLEANOUT WCO SYSTEMS, BEFORE THE PIPES ARE CONCEALED OR FIXTURES SET IN PLACE.
14F. THE FIRST 8 FEET OF THE COLD WATER PIPE FROM THE WATER HEATER USE 3/4" THESE TESTS MAY BE APPLIED IN SECTIONS. CLOSE ALL OPENINGS TO EACH
SHOWER DRAIN SWD
WATER HAMMER ARRESTOR WHA WATER HAMMER ARRESTOR ARMAFLEX OR IMCOA IMCOLOCK INSULATION. SYSTEM TO BE TESTED EXCEPT THE HIGHEST OPENING ABOVE THE ROOF AND

SECURITY DATA
INSULATE PER A.D.A. ALL EXPOSED HANDICAP LAVATORIES DRAIN PIPING AND HOT & FILL THE SYSTEM WITH WATER UP TO THE OVERFLOW POINTS OF THIS HIGHEST

RELOCATION,

EVERGLADES
TRAP PRIMER TP COLD STOP AND SUPPLIES. COVERS SHALL BE SOFT, REMOVABLE AND UPC APPROVED. OPENING. SUBJECT ALL PARTS OF THE SYSTEM TO NOT LESS THAN 10' OF
MANUFACTURE: PLUMBEREX HANDY-SHIELD OR PRO-SERIES. THE PIPING DIRECTLY BELOW THE OPENING. LEAVE THE WATER IN THE SYSTEM
SIOUX CHIEF SIZING AND SELECTION

HOLLYWOOD FL33316
NOTE: FOR NOT LESS THAN 30 MINUTES. AFTER WHICH TIME NO LEAKS AT NAY POINT

1901 ELLER DRIVE


14G. INSULATION IN ANY FIRE RATED WALL ASSEMBLY SHALL BE PREFORMED FIBERGLASS PIPE

CENTER
NOT ALL SYMBOLS & ABBREVIATIONS APPLY TO THIS JOB. OR LOWERING OF THE WATER LEVEL AT THE OVERFLOW SHALL BE VISIBLE.
INSULATION.

PORT
14H. 31. ALL SHOWER VALVES SHALL BE ANTI-SCALD/ PRESSURE BALANCING.
ALL FIXTURES SHALL BE PROVIDED WITH READILY ACCESSIBLE STOPS & APPROPRIATELY
P.D.I. UNITS A B C D E F MARKED ACCESS PANELS. COORDINATE LOCATIONS WITH GENERAL CONTRACTOR PRIOR 32. ALL PLUMBING FIXTURES SHALL MEET STATE AND LOCAL CODES.
TO INSTALLATION.
33. ALL WATER HEATERS SHALL HAVE ASME RATED EXPANSION TANKS AND APPROVED
FIXTURES UNITS 1-11 12-32 33-60 61-113 114-154 155-330 15. DIELECTRIC COUPLINGS ARE REQUIRED BETWEEN ALL DISSIMILAR METAL IN PIPING EXPANSION VALVES.
AND EQUIPMENT CONNECTIONS.
34. ALL SINKS AND LAVATORIES WITH EXPOSED DRAIN PIPES SHALL BE CHROME
16. HANGERS & RODS: PLATED COPPER TUBE, ALL BRANCH WASTE PIPING IN WALLS TO BE PLAIN
ALL HANGERS AND RODS IN GARAGE AREAS TO BE GALVANIZED. COPPER TUBE.
ALL HANGERS FOR COPPER PIPES TO BE COPPER PLATED.
NOTES: 35. INSTALLATION OF ALL DWV PIPING SHALL COMPLY WITH ASTM F 2536.
PROVIDE ISOLATOR PADS ON ALL WATER PIPING HANGERS.
36. PROVIDE A CLEANOUTS AT BASE OF EACH SOIL OF WASTE STACK
1. CONTRACTOR TO INSTALL WATER HAMMER ARRESTOR AS PER MANUFACTURER INSTRUCTIONS. 17. ALL FIRE RATED FLOOR AND WALL PENETRATIONS SHALL BE PROPERLY PROTECTED
FROM FIRE, SMOKE AND WATER PENETRATION BY FILLING VOIDS BETWEEN PIPE & 37. ALL FLOOR DRAINS SHALL BE PROVIDED WITH A TRAP FOR TRAP SEAL
2. CONTRACTOR TO INSTALL WATER HAMMER ARRESTORS WHERE QUICK CLOSING VALVES ARE PRESENT.
WALL/FLOOR SLEEVES WITH U.L. APPROVED FIRE/SMOKE/WATER SEALANT. PHASE:
38. FLOOR DRAIN RESEALS SHALL BE FROM A WATER CLOSET FLUSH VALVE
3. CONTRACTOR TO PROVIDE ACCESS DOORS/PANELS WHERE REQUIRED TO SERVICE WATER HAMMER
PERMIT SET
18. CONTRACTOR SHALL GUARANTEE ALL MATERIALS & WORKMANSHIP FREE FROM TAIL PIECE UNLESS OTHERWISE NOTED. FLUSH VALVE WITH TRAP PRIMER ASSEMBLY
ARRESTORS.
DEFECTS FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR FROM DATE OF 39. ALL HORIZONTAL PIPING 3" AND LARGER SHALL BE SLOPED @ 1/8" PER FOOT.
ACCEPTANCE BY OWNER. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED ALL HORIZONTAL PIPING 2½" AND SMALLER SHALL BE SLOPED AT ¼" PER FOOT.
WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR
PLUMBING INDEX 19.
OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED.
PROVIDE 1/2" TRAP PRIMER LINE FOR ALL FLOOR DRAINS FED BY THE NEAREST
40. PROVIDE 24" X 24" X 4" CONCRETE PAD FOR ALL CLEANOUTS LOCATED IN GRASS
OR EARTH AREAS
Note: This drawing is protected by
copyright. It shall not be transmitted to
Sheet Number Sheet Name Revision # FOR EXACT LOCATION OF ALL PLUMBING FIXTURES SEE ARCHITECT'S DWGS.
WATER CLOSET FLUSH VALVE TAILPIECE IN ORDER TO PREVENT EVAPORATION OF THE TRAP. 41. any other except as agreed to by the
SEALS. IN AREAS WHERE WATER CLOSET FLUSH VALVES ARE NOT AVAILABLE, CONNECTION 42. CLEANOUTS SMALLER THAN 3" SHALL BE SO INSTALLED THAT THERE IS A CLEARANCE Architect/Engineers
P-0.1 PLUMBING GENERAL NOTES
SHALL BE MADE TO LAVATORIES OR DOMESTIC WATER PIPING. PROVIDE SIOUX CHIEF #695-D20 OF NOT LESS THAN 12 INCHES FOR THE PURPOSE OF RODDING.
P-1.1 S.O.C BUILDING. DOMESTIC WATER SECOND FLOOR PLAN DISTRIBUTOR FOR MULTIPLE TRAP PRIMERS UP TO EIGHT TRAPS PER SINGLE TRAP PRIMER SEAL:
CLEANOUTS ON 3 INCHES OR LARGER PIPES SHALL BE SO LOCATED THAT THERE IS
P-1.2 SANITARY GROUND FLOOR PLAN. S.O.C BUILDING DISTRIBUTOR. A CLEARANCE OF NOT LESS THAN 18 INCHES FOR THE PURPOSE OF RODDING.
P-1.3 S.O.C BUILDING. SANITARY SECOND FLOOR PLAN
20. PROVIDE ACCESS PANELS FOR ALL CONCEALED VALVES. ACCESS PANELS IN RATED WALLS 43. PROVIDE GALVANIZED IRON SLEEVES FOR PIPES PASSING THROUGH WALLS OR
P-1.6 S.O.C BUILDING. STORM ROOF PLAN
MUST MAINTAIN THE SAME RATING & MUST MATCH THE FINISH OF THE WALL IN WHICH IT PARTITIONS.
P-2.0 S.O.C BUILDING. DOMESTIC WATER AND SANITARY PIPING ISOMETRIC
IS INSTALLED. COORDINATE LOCATION OF ALL ACCESS PANELS WITH ARCHITECT PRIOR TO
P-5.0 PLUMBING DETAILS
INSTALLATION.
21. PROVIDE CHROME PLATED COMBINATION COVER PLATE & CLEANOUT PLUG OR
ACCESS PANEL FOR ALL WALL CLEANOUTS ZURN ZS-1469-VP SERIES C.O. OR
APPROVED ACCESS PANEL.

REVISIONS:
No.: DESCRIPTION DATE:

TITLE:
PLUMBING GENERAL
NOTES

Project No: Project Number


Date: 12/08/2023
Scale:
Format: 24" x 36"
Drawn: H.A
Checked: JGC

SHEET:

P-0.1
DESIGN PROPERTY OF AND © COPYRIGHT BERMELLO AJAMIL & PARTNERS, INC.
ARCHITECT:
Bermello Ajamil & Partners
4711 South LeJeune Road
Coral Gables, FL 33146
P: 305.859.2050
C MEP ENGINEER:
Hammond & Associates, Inc
499 NW 70th Avenue, Suite 201
Plantation, FL 33317
P: 954.327.7111
WATER HAMMER ARRESTOR
STRUCTURAL ENGINEER:
TYPE B.
S & F Engineers, Inc
2925 W. Cypress Creek Rd., Suite 200
1 1/2"ø CW 1 1/2"ø CW Fort Lauderdale, FL 33309
P:954.938.0020
2" CW RISER 1 1/2"ø CW 3/4"ø CW GEOTECHNICAL ENGINEER:
3/4"ø CW
FROM BELOW GCES Engineering
(42 G.P.M.) L-1 Services, LLC.
10860 NW 138th Street, Unit 4,
3/4"ø HW 3/4"ø HW Hialeah Gardens, FL 33018
WC-1 WC-1
L-1 P: 305.964.0669
COST ESTIMATOR:
Program Control, Inc
3/4"ø HW
3150 SW 38th Avenue
Suite 1304, Miami, FL 33146

1"ø CW
P: 786.229.4416
3/4"ø HW 1"ø HW WATER HAMMER ARRESTOR SURVEYOR:
TYPE A Premiere Design Solutions
11606 City Hall Promenade, Ste 200,
Miramar, FL 33025
3/4"ø CW 3/4"ø CW 3/4"ø CW P: 954.237.7850
3/4"ø HW
OWNER:
3/4"ø CW MS-1
PORT EVERGLADES
DEPARTMENT OF
EWC-1 BROWARD COUNTY

SECURITY DATA

RELOCATION,

EVERGLADES
HOLLYWOOD FL33316
1901 ELLER DRIVE
CENTER

PORT
S.O.C BUILDING. ENLARGED - DOMESTIC WATER SECOND FLOOR PLAN
2
3/8" = 1'-0"

A B C D E F

PHASE:

PERMIT SET

Note: This drawing is protected by


copyright. It shall not be transmitted to
1 any other except as agreed to by the
Architect/Engineers
2 SEAL:

2" CW RISER
WATER HAMMER ARESTOR
FROM BELOW REVISIONS:
TYPE B.
(42 G.P.M.)
1 1/2"ø CW
No.: DESCRIPTION DATE:
1 1/2"ø CW

PROVIDE 3/4" HOSE BIBB AT WALL 3/4"ø HW 3/4"ø HW


WC-1 L-1 L-1 WC-1
1"ø CW 1"ø HW
3/4"ø HW
3/4"ø CW 20 GALLONS
3/4"ø CW 3/4"ø HW
3/4"ø CW
EWC-1
MS-1 WATER HAMMER ARESTOR
3/4"ø CW 3/4"ø CW 3/4"ø CW TYPE A.

4 TITLE:
S.O.C BUILDING.
5 DOMESTIC WATER
SECOND FLOOR PLAN
Project No: Project Number
Date: 12/08/2023
Scale: As indicated
S.O.C BUILDING. DOMESTIC WATER SECOND FLOOR PLAN
1 Format: 24" x 36"
1/8" = 1'-0"
Drawn: H.A
Checked: JGC

SHEET:

P-1.1
DESIGN PROPERTY OF AND © COPYRIGHT BERMELLO AJAMIL & PARTNERS, INC.
ARCHITECT:
Bermello Ajamil & Partners
4711 South LeJeune Road
Coral Gables, FL 33146
P: 305.859.2050

MEP ENGINEER:
Hammond & Associates, Inc
499 NW 70th Avenue, Suite 201
Plantation, FL 33317
P: 954.327.7111
STRUCTURAL ENGINEER:
S & F Engineers, Inc
2925 W. Cypress Creek Rd., Suite 200
A B C D E F Fort Lauderdale, FL 33309
P:954.938.0020
GEOTECHNICAL ENGINEER:
GCES Engineering
Services, LLC.
10860 NW 138th Street, Unit 4,
Hialeah Gardens, FL 33018
P: 305.964.0669
COST ESTIMATOR:
Program Control, Inc
1 3150 SW 38th Avenue
Suite 1304, Miami, FL 33146
P: 786.229.4416
2 SURVEYOR:
Premiere Design Solutions
11606 City Hall Promenade, Ste 200,
Miramar, FL 33025
P: 954.237.7850
1¼" CONDENSATE PIPING
OWNER:
FROM SECOND FLOOR
4" SANITARY RISER FROM SECOND
DOWN TO GROUNG FLOOR
CEILING. FLOOR RESTROOMS DOWN TO PORT EVERGLADES
1¼" CONDENSATE RISER
FROM SECOND FLOOR
GROUND FLOOR RESTROOMS IN A
CHASE TO CONNECT TO EXISTING
DEPARTMENT OF
MECHANICAL ROOM DOWN SANITARY PIPING BELOW GRADE LOCATION OF THE BROWARD COUNTY
TO GROUND FLOOR EXISTING SANITARY (17 DFU'S). ELEVATOR SUMP PUMP
MECHANICAL ROOM TO PIPING BELOW GRADE.
CONNECT TO EXISTING 2" CONTRACTOR SHALL POINT OF NEW
CONDENSATE PIPING CONFIRM THE PIPE

SECURITY DATA
CONNECTION
BELOW GRADE. SIZE ON FIELD.

RELOCATION,

EVERGLADES
1 1/4"ø CD
4"ø SAN

HOLLYWOOD FL33316
ESP-1

11

1901 ELLER DRIVE


/4"
1 1/4"ø CD 5O GPM

CENTER
ø
EXIST. EXIST. EXIST. EXIST. EXIST.

CD

PORT
WC-2 L-2 WC-2 L-2 EWC-1 1 1/2"ø
3" SANITARY RISER FROM SECOND GOOSENECK UP 8" AFF
1 1/4"ø CD FLOOR DOWN TO GROUND FLOOR AND TERMINATE 1" ABOVE
THEN CONNECT TO 3" EXISTING FLOOR DRAIN
EXIST. POINT OF NEW
SANITARY PIPING BELOW GRADE MS-1 CONNECTION FS-1

LOCATION OF THE NEW 2" VENT UP TO THE CEILING


NEW FLOOR SINK THEN GO TO A 2" VENT ON THE
POINT OF NEW CONNECTION SOUTH WALL.

4 POINT OF NEW CONNECTION


EXISTING 4" SANITARY PIPING BELOW GRADE
EXISTING 3" SANITARY PIPING BELOW GRADE NEW 3" SANITARY PIPING BELOW GRADE
5 PHASE:

PERMIT SET

Note: This drawing is protected by


SANITARY GROUND FLOOR PLAN. S.O.C BUILDING
2 copyright. It shall not be transmitted to
1/8" = 1'-0" any other except as agreed to by the
Architect/Engineers

SEAL:

REVISIONS:
No.: DESCRIPTION DATE:

TITLE:
SANITARY GROUND
FLOOR PLAN. S.O.C
BUILDING
Project No: Project Number
Date: 12/08/2023
Scale: 1/8" = 1'-0"
Format: 24" x 36"
Drawn: H.A
Checked: JGC

SHEET:

P-1.2
DESIGN PROPERTY OF AND © COPYRIGHT BERMELLO AJAMIL & PARTNERS, INC.
ARCHITECT:
Bermello Ajamil & Partners
4711 South LeJeune Road
Coral Gables, FL 33146
4" SANITARY RISER C P: 305.859.2050
DOWN TO BELOW MEP ENGINEER:
(17 DFU'S)
Hammond & Associates, Inc
499 NW 70th Avenue, Suite 201
2" VENT Plantation, FL 33317
3" V.T.R.
2" VENT 2" VENT P: 954.327.7111
STRUCTURAL ENGINEER:
3"ø SAN S & F Engineers, Inc
2925 W. Cypress Creek Rd., Suite 200
3"ø SAN Fort Lauderdale, FL 33309
P:954.938.0020
GEOTECHNICAL ENGINEER:
FD-1 W.C.O. GCES Engineering
FD-1 Services, LLC.

3"ø SAN
10860 NW 138th Street, Unit 4,
WC-1 L-1 L-1 WC-1
Hialeah Gardens, FL 33018
3"
ø
SA P: 305.964.0669
N

3"
COST ESTIMATOR:

ø
SA
Program Control, Inc

N
3"ø SAN
3150 SW 38th Avenue
3"ø SAN Suite 1304, Miami, FL 33146
2" VENT P: 786.229.4416
SURVEYOR:
Premiere Design Solutions

AN
2" 11606 City Hall Promenade, Ste 200,

øS
ø
SA 2" VENT
2" VENT Miramar, FL 33025

2"
N

N
SA
P: 954.237.7850

ø
1"
2"ø SAN MS-1

1"
OWNER:

ø
SA
PORT EVERGLADES

N
DEPARTMENT OF
EWC-1 BROWARD COUNTY

S.O.C BUILDING. ENLARGED - SANITARY SECOND FLOOR PLAN


2

SECURITY DATA
3/8" = 1'-0"

RELOCATION,

EVERGLADES
HOLLYWOOD FL33316
1901 ELLER DRIVE
CENTER

PORT
A B C D E F

PHASE:

PERMIT SET

Note: This drawing is protected by


1 copyright. It shall not be transmitted to
any other except as agreed to by the
Architect/Engineers
2 SEAL:

1¼" CONDENSATE RISER


DOWN TO GROUND FLOOR 4" LINE DOWN TO
CEILING THEN CONNECT GROUND FLOOR
TO NEW 1¼" CONDENSATE (17 DFU'S)
PIPING IN THE CEILING.
REVISIONS:
CRAC-4 3"ø SAN 3"ø SAN No.: DESCRIPTION DATE:
7.5 TONS

3"
2"ø SAN 2"ø SAN

ø
AHU-5

SA
L-1

N
12.5 TONS
WC-1 3"ø L-1 WC-1
SA 3"ø SAN
2" V.T.R N

AN
3"ø SAN 2"ø SAN

øS
2"
2"ø SAN 3"FD 3"FD
3"ø SAN W/TP MS-1
W/TP
1"ø SAN 1"ø SAN
3" LINE DOWN TO EWC-1
3"FD GROUND FLOOR
W/TP
4 TITLE:
S.O.C BUILDING.
5 SANITARY SECOND
FLOOR PLAN
Project No: Project Number
Date: 12/08/2023
S.O.C BUILDING. SANITARY SECOND FLOOR PLAN Scale: As indicated
`
1/8" = 1'-0" Format: 24" x 36"
Drawn: H.A
Checked: JGC

SHEET:

P-1.3
DESIGN PROPERTY OF AND © COPYRIGHT BERMELLO AJAMIL & PARTNERS, INC.
ARCHITECT:
Bermello Ajamil & Partners
A B C D E F 4711 South LeJeune Road
Coral Gables, FL 33146
P: 305.859.2050
1 MEP ENGINEER:
Hammond & Associates, Inc
2 499 NW 70th Avenue, Suite 201
Plantation, FL 33317
P: 954.327.7111
ROOF LINE DIVIDER FOR ARE 2
STRUCTURAL ENGINEER:
S & F Engineers, Inc
2925 W. Cypress Creek Rd., Suite 200
Fort Lauderdale, FL 33309
P:954.938.0020
AREA 2 GEOTECHNICAL ENGINEER:
AREA 1 GCES Engineering
Services, LLC.
3" VENT THROUGH ROOF
(V.R.T). 10860 NW 138th Street, Unit 4,
EMERGENCY OVERFLOW SCUPPER Hialeah Gardens, FL 33018
P: 305.964.0669
ROOF LINE DIVIDER FOR ARE 1 COST ESTIMATOR:
Program Control, Inc
RECTANGULAR DOWNPOUT WITH ROUND PIPING 3150 SW 38th Avenue
2" VENT THROUGH ROOF TRANSITION TO 6" ABOVE FINISH FLOOR Suite 1304, Miami, FL 33146
(V.R.T). RECTANGULAR DOWNPOUT WITH ROUND PIPING P: 786.229.4416
TRANSITION TO 6" ABOVE FINISH FLOOR
SURVEYOR:
RECTANGULAR DOWNPOUT WITH ROUND PIPING
RECTANGULAR DOWNPOUT WITH ROUND PIPING
Premiere Design Solutions
TRANSITION TO 6" ABOVE FINISH FLOOR(A.F.F).
TRANSITION TO 6" ABOVE FINISH FLOOR 11606 City Hall Promenade, Ste 200,
EMERGENCY OVERFLOW SCUPPER Miramar, FL 33025
EMERGENCY OVERFLOW SCUPPER P: 954.237.7850

4 OWNER:

4" SD PIPING BELOW GRADE. SEE 4" SD PIPING BELOW GRADE. SEE 4" SD PIPING BELOW GRADE. SEE 4" SD PIPING BELOW GRADE. SEE PORT EVERGLADES
5 CIVIL PLAN FOR CONTINUATION CIVIL PLAN FOR CONTINUATION CIVIL PLAN FOR CONTINUATION CIVIL PLAN FOR CONTINUATION EMERGENCY OVERFLOW SCUPPER DEPARTMENT OF
BROWARD COUNTY
S.O.C BUILDING. STORM ROOF PLAN
2
1/8" = 1'-0"

SECURITY DATA

RELOCATION,

EVERGLADES
HOLLYWOOD FL33316
1901 ELLER DRIVE
CENTER

PORT
PHASE:

PERMIT SET

Note: This drawing is protected by


copyright. It shall not be transmitted to
any other except as agreed to by the
Architect/Engineers

SEAL:

REVISIONS:
No.: DESCRIPTION DATE:

TITLE:
S.O.C BUILDING. STORM
ROOF PLAN

Project No: Project Number


Date: 12/08/2023
Scale: 1/8" = 1'-0"
Format: 24" x 36"
Drawn: H.A
Checked: JGC

SHEET:

P-1.6
DESIGN PROPERTY OF AND © COPYRIGHT BERMELLO AJAMIL & PARTNERS, INC.
ARCHITECT:
Bermello Ajamil & Partners
4711 South LeJeune Road
Coral Gables, FL 33146
P: 305.859.2050

MEP ENGINEER:
Hammond & Associates, Inc
499 NW 70th Avenue, Suite 201
Plantation, FL 33317
P: 954.327.7111
STRUCTURAL ENGINEER:
S & F Engineers, Inc
2925 W. Cypress Creek Rd., Suite 200
Fort Lauderdale, FL 33309
P:954.938.0020
GEOTECHNICAL ENGINEER:
GCES Engineering
WATER HAMMER Services, LLC.
ARRESTOR 3" ⌀ VENT THROUGH ROOF (V.T.R).
10860 NW 138th Street, Unit 4,
( TYPE A). Hialeah Gardens, FL 33018
P: 305.964.0669
3/4"⌀ CW COST ESTIMATOR:
3/4"⌀ H&CW
Program Control, Inc
20 GALLONS WATER 3150 SW 38th Avenue
Suite 1304, Miami, FL 33146
HEATER HUNG ON WALL. P: 786.229.4416

1"⌀ CW 3/4"⌀ H&CW 2"⌀ VENT 2"⌀ VENT


SURVEYOR:
3"⌀ VENT Premiere Design Solutions
L-1 11606 City Hall Promenade, Ste 200,
WC-1 2"⌀ VENT Miramar, FL 33025
L-1 3"⌀ VENT P: 954.237.7850
1"⌀ CW
3/4"⌀ CW 2"⌀ VENT OWNER:
3"⌀ SAN WC-1
2"⌀ VENT
2"⌀ VENT L-1 PORT EVERGLADES
MS-1 3"⌀ SAN
L-1
DEPARTMENT OF
WATER HAMMER BROWARD COUNTY
ARRESTOR 3/4"⌀ CW 3"⌀ SAN MS-1
WC-1 FD-1
( TYPE B) 3/4" COLD WATER PIPIPNG TO
HOSE BIBB IN MECHANICAL

SECURITY DATA
ROOM.

RELOCATION,

EVERGLADES
FD-1 3"⌀ SAN
2"⌀ SAN
WC-1

HOLLYWOOD FL33316
W.C.O 3"⌀ SAN

1901 ELLER DRIVE


CENTER
2" CW RISER FROM EWC-1 2"⌀ VENT

PORT
BELOW.(42 G.P.M 2"⌀ VENT
4" SANITARY RISER DOWN BELOW TO
CONNECT TO EXISTING 4" SANITARY
PIPING(17DFU'S).
EWC-1

S.O.C BUILDING. DOMESTIC WATER ISOMETRIC SECOND FLOOR PLAN 2"⌀ SAN
1

S.O.C BUILDING. SANITARY ISOMETRIC SECOND FLOOR PLAN


2
PHASE:

PERMIT SET

Note: This drawing is protected by


copyright. It shall not be transmitted to
any other except as agreed to by the
Architect/Engineers

SEAL:

2" VENT IN THE FIRST FLOOR CEILING

2" VENT ON THE SOUTH WALL

2"⌀
REVISIONS:
PLUMBING GENERAL NOTES: POINT OF NEW No.: DESCRIPTION DATE:
1½"⌀
CONNECTION
1. FIRST FLOOR SANITARY ISOMETRIC IS A PARTIAL , NOT A COMPLETE ISOMETRIC. FS-1 3"⌀ SAN
ESP-1
3"⌀ SAN

EXISTING 4" SANITARY


PIPING BELOW GRADE

S.O.C BUILDING. SANITARY ISOMETRIC FIRST FLOOR TITLE:


3
S.O.C BUILDING.
DOMESTIC WATER AND
SANITARY PIPING
ISOMETRIC
Project No: Project Number
Date: 12/08/2023
Scale:
Format: 24" x 36"
Drawn: H.A
Checked: JGC

SHEET:

P-2.0
DESIGN PROPERTY OF AND © COPYRIGHT BERMELLO AJAMIL & PARTNERS, INC.
ARCHITECT:
CORK BLOCK WALL HANGERS
TRAP SEALS. IN AREAS WHERE WATER CLOSET FLUSH Bermello Ajamil & Partners
A
A
VALVES ARE NOT AVAILABLE, MAKE CONNECTION TO 4711 South LeJeune Road
D
LAVATORIES OR DOMESTIC WATER PIPING. Coral Gables, FL 33146
C P: 305.859.2050
B

MEP ENGINEER:
INSULATION
PIPE SLEEVE Hammond & Associates, Inc
PIPE 499 NW 70th Avenue, Suite 201
CLEVIS HANGER FLAT IRON HANGER U-TYPE HANGER
(Only for wood const.) Plantation, FL 33317
LAVATORY P: 954.327.7111
FASTENERS
STRUCTURAL ENGINEER:
J.R. SMITH
# 2698
S & F Engineers, Inc
WATER SAVER 2925 W. Cypress Creek Rd., Suite 200
A A A TRAP PRIMER Fort Lauderdale, FL 33309
P:954.938.0020
CLEANOUT PLUG
GEOTECHNICAL ENGINEER:
FINISHED FLOOR FINISHED
ANCHOR
WALL GCES Engineering
CENTER I-BEAM CLAMP SELF DRILLING ANCHOR TOP BEAM CLAMP
WELDED TO PIPE Services, LLC.
SLEEVE 90 O.C.
10860 NW 138th Street, Unit 4,
Hialeah Gardens, FL 33018
FLOOR
P: 305.964.0669
DRAIN COST ESTIMATOR:
Program Control, Inc
3150 SW 38th Avenue
PIPE THRU WALL DETAIL PIPE HANGING DETAIL TRAP PRIMER DETAIL Suite 1304, Miami, FL 33146
1 2 3 P: 786.229.4416
SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. SURVEYOR:
Premiere Design Solutions
11606 City Hall Promenade, Ste 200,
Miramar, FL 33025
P: 954.237.7850
OWNER:
2
PORT EVERGLADES
3/4" CONNECTION STAINLESS STEEL COVER
12"x12"x8" SCREWED TO THREADED 1 DEPARTMENT OF
POURED CONC. C.O. PLUG
LESS FLANGE WHERE
BLOCK WHEN BROWARD COUNTY
ATTACHED TO CLEANOUT IS FACE OF WALL
EXPOSED PIPING NOT IN PAVED
AREA

SECURITY DATA
WALL-TYPE CLEAN-OUT

RELOCATION,

EVERGLADES
1. CLEVIS TYPE PIPE HANGER
2-WAY, CLEAN-OUT @ GRADE 3
2. THREADED ROD CUT TO LENGTH
3. SHIELD FOR INSULATION -

HOLLYWOOD FL33316
LENGTH 1.5 TIMES INSULATION

1901 ELLER DRIVE


CENTER
ROUGH CHROME PLATED DIAMETER
REMOVABLE TEE FINISH GRADE 4. INSULATION

PORT
4
HANDLE ZURN 2N-1400 5. CARRIER PIPE
CLEAN-OUT COVER 5
VACUUM BREAKER
3/4" HOSE THREAD (VANDAL PROOF)

SAME SIZE AS
12"x12"x8" SEWER - MAX.
SAME SIZE AS POURED CONC. SIZE 4"
SEWER - MAX.
SIZE 4" BLOCK WHEN LONG SWEEP. USE SHORT
CLEANOUT IS SWEEP WHERE REQUIRES
NOT IN PAVED
AREA

1-WAY, INTERIOR CLEAN-OUT 1-WAY, CLEAN-OUT @ GRADE


PHASE:

PERMIT SET
HOSE BIBB DETAIL TYPICAL CLEAN-OUT DETAILS CLEVIS TYPE PIPE HANGER DETAIL
4 5 6 Note: This drawing is protected by
SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. copyright. It shall not be transmitted to
any other except as agreed to by the
Architect/Engineers

SEAL:
3/4" C.W. 3/4" H.W.
FINISHED CELING OR
EXPOSED STRUCTURE
FLOOR DRAIN FLOOR WALL
TOP OF FLASHING CAPPED
OR ROLLED INTO PIPE
WATER HEATER
APPROXIMATELY 1'' HEAT TRAPS
1 5 CAP FLASHING
3
BASE FLASHING PRESSURE AND
2 TEMPERATURE
CAP SHEET PLUMBING VENT STACK GATE VALVE RELIEF VALVE.
LEAD BOOT 3/4" RELIEF
4
4'' MIN. DRAIN LINE.
REVISIONS:
8" MIN.
4
FLANGE
FLUSH VALVE
FLOOR DRAIN 1" SCHEDULE 40 No.: DESCRIPTION DATE:
PVC SAFETY PAN
DRAIN LINE.
SAFETY PAN
NOTES
THIS DETAIL APPLICABLE FOR RESEALING OF ALL TOILET
ROOM FLOOR DRAINS. ALL OTHER FLOOR DRAINS ARE TO BE
RESEALED BY MEANS OF A JOSAM #88250BB (CPB) PRIMER

MIN. 18"
VALVE INSTALLED IN THE C.W. SUPPLY LINE OF THE
B-LINE FIG. B26 CHANNEL
NEAREST SINK AND SLOPED TO THE FLOOR DRAIN. BOLTED TOGETHER TO FORM
BRACKET. (TWO REQUIRED)

TERMINATE OVER
1 FLUSH VALVE (SLOAN ROYAL #113-F72-A) SERVICE SINK.
2 TRAP PRIMER FITTING
3 1/2" NOM. 0 X SWEAT X 3/8" O.DO EL. W/ ESCUTCHEON
4 1/2" TRAP PRIMER LINE WITH SLOPE TO FLOOR DRAIN EXISTING ROOF DECK 1/4" TAPCON INSTALLED USING TITLE:
MFGR. MATCHED TOLLERENCE
5
3/8" CHROME PLATED SUPPLY (McGUIRE OR EQUAL) PILOT DRILL BIT. (TYPICAL FOR 4) PLUMBING DETAILS

TRAP RESEAL DIAGRAM PLUMBING VENT THRU ROOF DETAIL WATER HEATER DETAIL
7 8 9 Project No: Project Number
SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. Date: 12/08/2023
Scale:
Format: 24" x 36"
Drawn: H.A
Checked: JGC

SHEET:

P-5.0
DESIGN PROPERTY OF AND © COPYRIGHT BERMELLO AJAMIL & PARTNERS, INC.

You might also like