0% found this document useful (0 votes)
13 views8 pages

10 Daa26200cf

This document is a spare parts leaflet for the GECS-ANSI Controller of the Non-Regen system, detailing the replaceable units and their specifications. It includes a history of revisions, related drawings, and documents, as well as instructions for ASN-V setting. The leaflet aims to facilitate parts identification, although it does not cover custom elevator and escalator contracts.

Uploaded by

muaadh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
13 views8 pages

10 Daa26200cf

This document is a spare parts leaflet for the GECS-ANSI Controller of the Non-Regen system, detailing the replaceable units and their specifications. It includes a history of revisions, related drawings, and documents, as well as instructions for ASN-V setting. The leaflet aims to facilitate parts identification, although it does not cover custom elevator and escalator contracts.

Uploaded by

muaadh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Spare Parts Leaflet

GECE-ANSI NON REGEN


CONTROLLER 10-DAA26200CF
Jan. 4th, 2013 / Page 1 of 8

Unpublished Work—© Otis Elevator Co. SERVICE ENGINEERING


This document contains technical
data subject to EAR, ECCN=EAR99 Otis Elevator Company
Shanghai Electronics SSI

PDP00073
Spare Parts Leaflet Template
10-DAA26200CF History

Leaflet Description
This leaflet describes the spare parts that may be ordered for GECS-ANSI Controller of None Regen system.
Regarding the SPL for GECS-ANSI Controller of Regen System, please reference to DAA26200BW_SPL.

Leaflet Revisions
Date Revised Subject Matter Expert Reason for Revision
Jan. 4th, 2013 Andy Li New SPL
Jul. 7th, 014 Major Xing Updated
Sep. 9th, 2014 Haijun Zheng Changed DBA26800AH1 to DBA26800AH11
Jun. 8th, 2015 Major Xing Added ERMS terminator option
Aug 16, 2017 Robin Zhou Updated items
Sep. 6th, 2018 Kee Yuan Updated Terminal Resistor for ERMS PN.
Mar. 29th, 2019 Bo Liu Added WIFI DONGLE
Dec. 23rd, 2019 Bo Liu Added change record of previous version.
Mar.16th, 2021 Kee Yuan Added auxiliary contact
Nov.2nd, 2022 Tony Wang CNT2200991, ASN-V setting added
Feb. 9th, 2023 Tony Wang Update format of date

Related Drawings
Drawing No. Title Drawing No. Title
DAA26200CF Controller of none regen Layout DAA26400AB Master wiring diagram

Related Documents
Document ID Title
DAA26200CF_ODS Controller of none regen ODS

Subject Matter Expert


Name Department
Daniel Wang Shanghai Electronics SSI

About Spare Parts Leaflets…


This document lists the lowest replaceable units (LRUs) for the standard version of the product. The LRUs
are chosen by a team of Otis associates representing engineering and manufacturing.
While goal of this document is to make parts identification as easy as possible, the document cannot be all-
inclusive. Elevator and escalator contracts classified as “special” or “custom” are not addressed here. For
such contracts, please refer to specified information, the contract folder, TIPs, Field Education Articles,
Construction Letters, etc. for further information.
If you have any suggestions about this document, please contact the subject matter expert listed on this page.

This document contains technical data subject to EAR, ECCN=EAR99


Page 2 Feb. 9th, 2023 Unpublished Work—Otis Elevator Co.
DAA26200CF GECE-ANSI NON
10-DAA26200CF
REGEN CONTROLLER

VINTAGE

REF. No. PART No. DESCRIPTION


1 DAA621L1 PW1 - DC POWER SUPPLY 24V/50W
2 DAA621L1 PW2 - DC POWER SUPPLY 24V/50W
3 DAA621L6 PW3 - DC POWER SUPPLY FOR ERMS 12V/36W
AAA375BG30
F4&F5 - FUSE, 3.5A (SUPPLY VOLTAGE 200V-220V)
AAA375BK28
AAA375BG28
4-5 F4&F5 - FUSE, 2.5A (SUPPLY VOLTAGE 460V-480V)
AAA375BK24
AAA375BG27
F4&F5 - FUSE, 2A (SUPPLY VOLTAGE 575V/600V)
AAA375BK21
GAA375BY4
6 F6 – FUSE 2.5A
AAA375BK24
GAA375BY2
7 F7 – FUSE 0.5A
AAA375BK9
8 DAA225AM1 T9 - TRANSFORMER

This document contains technical data subject to EAR, ECCN=EAR99


Page 3 Feb. 9th, 2023 Unpublished Work—Otis Elevator Co.
DAA26200CF GECE-ANSI NON
10-DAA26200CF
REGEN CONTROLLER

VINTAGE

REF. No. PART No. DESCRIPTION


GAA375BY1
9-11 F1, F2, F3 – FUSE, 0.5 A
AAA375BK9
DBA26800AH1
GECB – Global Escalator Control Board
DBA26800AH11
12
D**231602*** GECB Software * Ref to Esc. Software Version Control at PDMLink
DBA26800EP1 ERMS Terminator (Only for ERMS option)

This document contains technical data subject to EAR, ECCN=EAR99


Page 4 Feb. 9th, 2023 Unpublished Work—Otis Elevator Co.
DAA26200CF GECE-ANSI NON
10-DAA26200CF
REGEN CONTROLLER

VINTAGE

REF. No. PART No. DESCRIPTION


GAA613GR1 1K1,1K2 - SIEMENS RELAY
GAA638DP2
K3, K4 – SIEMENS CONTACTOR (Supply Voltage 200V-220V)
DAA638T9
DAA638V5 K3, K4 – SIEMENS AUXILIARY CONTACT (Supply Voltage 200V-220V)
13-14 GAA638DP2
GAA638CB2 K3, K4 – SIEMENS CONTACTOR (Supply Voltage 460V-600V)
DAA638T5
DAA638V1 K3, K4 – SIEMENS AUXILIARY CONTACT (Supply Voltage 460V-600V)
GAA638DR2
K1, K2 - SIEMENS CONTACTOR (Supply Voltage 200V-220V)
DAA638T10
GAA638DP2
GAA638CD2 K1, K2 - SIEMENS CONTACTOR (Supply Voltage 460V-600V)
15-16 DAA638T7
GAA638DP2
GAA638CC2 K1, K2 - SIEMENS CONTACTOR (Supply Voltage 575V-600V)
DAA638T6
DAA638V5 K1, K2 – SIEMENS AUXILIARY CONTACT (Supply Voltage 200V-600V)
17 GO225DS1 T10 – TRANSFORMER (Supply Voltage 575V/600V)

This document contains technical data subject to EAR, ECCN=EAR99


Page 5 Feb. 9th, 2023 Unpublished Work—Otis Elevator Co.
DAA26200CF GECE-ANSI NON
10-DAA26200CF
REGEN CONTROLLER

VINTAGE

REF. No. PART No. DESCRIPTION


DAA630H__
18 SOC – SIEMENS CIRCUIT BREAKER (See above table)
AAA660__
GBA26800MF20
19 MESB – OTIS MESB
GBA26800MF2
20 ABA27KW1 WI-FI DONGLE

This document contains technical data subject to EAR, ECCN=EAR99


Page 6 Feb. 9th, 2023 Unpublished Work—Otis Elevator Co.
DAA26200CF GECE-ANSI NON
10-DAA26200CF
REGEN CONTROLLER

ASN-V setting

ASN-V have been set into GCSECB in Otis factory before the Escalator shipped to
site(because the ambient temperature in testing room is 18°C~30°C). If GCSECB need to
be replaced by new GCSECB at site. ASN-V should be set into new GCSECB at site
again. Setting procedure follow the two steps below:
Ambient temperature: For ASN-V setting, 25°C is idea ambient temperature,
If setting need to be done in winter and ambient temperature is too low, let the GCSECB
run one hour in advance and then set the ASN-V.
Step 1
Use multimeter measure the incoming voltage of ASN terminal block P10 on control
board:
V1 is Voltage between L1 and L2
V2 is Voltage between L1 and L3
V3 is Voltage between L2 and L3

P10

ASN-V setting value = (V1+V2+V3)/3.

This document contains technical data subject to EAR, ECCN=EAR99


Page 7 Feb. 9th, 2023 Unpublished Work—Otis Elevator Co.
DAA26200CF GECE-ANSI NON
10-DAA26200CF
REGEN CONTROLLER
ASN-V setting
Step 2
Use SVT set the ASN-V value into GCSECB

This document contains technical data subject to EAR, ECCN=EAR99


Page 8 Feb. 9th, 2023 Unpublished Work—Otis Elevator Co.