Tie Max Spec Book
Tie Max Spec Book
www.tiemax.com
TIE MAX ITEM LIST
ZINC PLATED HOT DIPPED GALVANIZED
DESCRIPTION
Item # Packed Quantity Item # Packed Quantity
40951 25 EDGE BOLT 5/8 X 10-1/2 39070 25
40950 25 FIELD BOLT 5/8 X 10-1/2 39071 25
40960 25 STUD 5/8-11 X 10-1/2 39074 25
19892 1 STUD 5/8-11 X 16
40949 25 CURB BOLT 5/8-11 X 14-1/2 39072 25
40948 1 LONG BOLT 5/8-11 X 30 39073 1
40959 100 SQUARE WASHER 2X2X1/8X1/2 39083 50
40981 100 SQUARE WASHER 2X2X1/8X5/8 39084 50
40982 50 SQUARE WASHER 2-1/2X2-1/2X1/2
40984 100 SQUARE WASHER 3X3X1/2 SLOT 39086 25
40985 100 SQUARE WASHER 3X3X5/8 SLOT 39087 25
40988 100 SQUARE WASHER 3X3-1/2X1/2 N/A
40987 100 SQUARE WASHER 3X3-1/2X5/8 N/A
40956 50 HEX. NUT 1/2-13 39077 50
40962 25 HEX. NUT 5/8-11 39078 25
40963 25 REDUCING COUPLER 5/8 X 1/2 39081 25
40973 25 REDUCING COUPLER 5/8 HDG to 1/2 ZINC NEW
40955 25 ROD COUPLER 1/2-13 39079 25
40971 25 ROD COUPLER 1/2-13 HDG to ZINC NEW
40964 25 ROD COUPLER 5/8-11 39080 25
40972 25 ROD COUPLER 5/8-11 HDG to ZINC NEW
40966 12 THREADED ROD 1/2-13 X 2FT 39090 25
40967 12 THREADED ROD 1/2-13 X 3FT 39091 25
40945 12 THREADED ROD 1/2-13 X 5FT N/A
N/A THREADED ROD 1/2-13 X 6’ 39092 15
40952 12 THREADED ROD 1/2-13 X 8FT 39093 15
40975 12 THREADED ROD 1/2-13 X 9FT NEW N/A
40953 12 THREADED ROD 1/2-13 X 10FT 39094 15
40954 12 THREADED ROD 1/2-13 X 12FT 39095 15
40968 8 THREADED ROD 5/8-11 X 2FT 39096 15
40969 8 THREADED ROD 5/8-11 X 3FT 39097 15
40970 8 THREADED ROD 5/8-11 X 6FT 39098 9
40996 8 THREADED ROD 5/8-11 X 8FT 39099 9
40997 8 THREADED ROD 5/8-11 X 10FT 39100 9
40998 8 THREADED ROD 5/8-11 X 12FT 39101 9
42924 1 BLOW OUT BULB (PUFFER BALL)
42922 1 3/4” CLEAN OUT BRUSH
42949 1 TIE MAX EPOXY (10 OZ.)
42947 1 TIE MAX EPOXY (22 OZ.)
42940 1 22 OZ. TOOL (DUAL TUBE)
42941 1 NOZZLE (DUAL CARTRIDGE)
TIE MAX is a Structural Tie Down System. All components must be of TIE MAX manufacture.
Pricing and standard package quantities are subject to change without notice.
I TRUSSES NOT SHOWN FOR CLARITY I
TIE MAX IS NOT REQUIRED FOR
NON-TRUSS BEARING WALL CONTINUE TIE MAX TO FOUNDATION
TIE MAX COUPLING NUT
WASHER NOT REQUIRED AT
2ND FLOOR SOLE PLATE
#5 WALL REINF.
W/ GROUTED CELL
Field Placement
1. Determine the location of the TIE MAX Field bolt.
2. At the proper location, insert the TIE MAX Field bolt with its PVC pipe into the ground using a drive sleeve.
(1” X 12” Pipe) until the bottom of the threads are at the top of the slab elevation.
Important Note: Do not hammer top of bolt. It will not drive!
Edge Placement
1. Determine the location of the TIE MAX Edge bolt and mark the top of the form board for wet setting or place the TIE MAX
bolt reusable anchor hanger prior to concrete pour.
x Corner placement: The TIE MAX embed shall be located 7 inches to 22 inches away from the corner of the
structure to allow clearance for framing members.
x Exterior walls: The TIE MAX embeds shall be located 2 inches from the edge of slab with spacing as required to
meet uplift values.
2. Position the TIE MAX embeds with the bottom of the threads at the top of slab. This insures the required 7-inches of
embedment.
3. Make concrete pour. (The TIE MAX Edge bolt may be wet set during the pour.) Insert the TIE MAX bolt to the bottom of
the threads with a 2-inch distance and consolidate the concrete.)
Retrofit
In retrofit situations after the concrete has been placed, use a 10-1/2 inch long 5/8-inch diameter TIE MAX STUD. Install the
TIE MAX STUD with POWERS POWER BOND epoxy adhesive following all manufacturers’ instructions. See detail
instructions on the following page.
1. With wall framing in place, secure proper TIE MAX square washer to the sole plate with a 5/8 TIE MAX hex nut.
2. Install a TIE MAX 5/8” to 1/2” reducing coupler to the end of the TIE MAX threaded rod to be connected to the TIE MAX
embed. Drill holes in the top plate or base plate if 2 or more stories and insert the rod into the top plate. Pull down on the rod
till the end of the rod and the TIE MAX embed butt together. Spin the coupler down onto embed. (Center a TIE MAX 5/8” to
5/8” coupler when using 5/8” rod.)
3. Select threaded rod by length, which will allow sufficient room for couplers to be placed above or below double top plates
or base plates. Butt the ends of the threaded rods together, center coupler over the rod ends.
1. Place TIE MAX steel plate washer on the threaded rod above the double top plate. See Table 3-A or 3-B of the TIE MAX
Quick Reference sheet.
3. Just prior to installing interior wall sheathing, Hand tighten nuts, then one turn with wrench per floor to secure washer and
tension rod. The TIE MAX system does not require a specific amount of torque.
TIE MAX is a Structural Tie Down System. All components must be of TIE MAX manufacture.
TIE MAX STUD
Retrofit Application
Use only approved epoxies supplied by Fastening Specialists, Inc.
6. Inject epoxy into hole, filling the hole 1/2 full starting from
the bottom.
7. Insert the TIE MAX STUD with a twisting motion (to insure full thread coverage) until stud hits the bottom of the hole.
Note: If epoxy does not appear at the top of the hole when the TIE MAX STUD is inserted, remove TIE MAX STUD,
apply additional epoxy to the hole, and reinsert TIE MAX STUD with a twisting motion.
8. Allow epoxy to set as per manufacturer’s instructions before applying any load.
TIE MAX is a Structural Tie Down System. All components must be of TIE MAX manufacture.
TIE MAX
REFERENCIA RAPIDA
CARGAS DE DISEÑO EN CONCRETO
DISTANCIA
EMPOTRAMIENTO MINIMA VARILLA LEVANTAMIENTO FUERZA
MINIMO DEL TIE MAX PERMISIBLE LATERAL NOTAS
(in.) BORDE (in. Dia.) PERMISIBLE
(in.)
7 2 1/2 5585 lbs. 5343 lbs. A,B,D
5/8” PERNO 7 7 1/2 6023 lbs. 5343 lbs. A,B,D,
TIE MAX
7 7 5/8 8377 lbs. 5343 lbs. A,B,D
TABLA 1-B
A. Viga de bloque de concreto reforzada con (1) #5 reforzamiento mínimo
B. Resistencia del concreto: 2000 psi mínimo
C. Factor de Seguridad 5.0 según ACI 530
ARANDELA DE LA PLACA SUPERIOR TM, SYP ARANDELA DE LA PLACA SUPERIOR TM, SPF
ARANDELA DE LA LEVANTAMIENTO ARANDELA DE LA LEVANTAMIENTO
PLACA SUPERIOR PERMISIBLE PLACA SUPERIOR PERMISIBLE
2x2x1/8 2260 lbs. 2x2x1/8 1513 lbs.
2.5x2.5x3/16 3930 lbs. 2.5x2.5x3/16 2330 lbs.
3x3x1/4 5595 lbs. 3x3x1/4 3315 lbs.
3x3.5x1/4 6545 lbs. 3x3.5x1/4 3880 lbs.
TABLA 2-A Tabla 2-B
1. Cargas controladas por la madera incidiendo 1. Cargas controladas por la madera incidiendo perpendicularmente a
perpendicularmente a las fibras con una deformación de 0.04 las fibras con una deformación de 0.04 pulg. en carga máxima según
pulg. en carga máxima según NDS – 1997. NDS – 1997.
2. Arandela de la placa superior SYP#2, mínimo con Fc> 565 psi 2. Arandela de la placa superior SPF#2, mínimo con Fc>335 psi
2. En el lugar apropiado, inserte el Perno Interior TIE MAX con su tubo de PVC en la tierra usando una guía.
(TUBO 1” X 12”) hasta que toda la rosca este a nivel con la parte superior del cimiento.
Nota Importante: No martille el Perno. No va a ceder!
3. Verter el concreto.
x Posicionamiento en las esquinas: El empotramiento de TIE MAX debe ser localizado de 7 a 22 pulgadas a partir
de la esquina para posibilitar espacio para la partes de madera.
x Paredes Exteriores: Los empotramientos de TIE MAX deben ser localizados a 2 pulgadas del borde del cimiento
para satisfacer los valores de levantamiento admisibles.
2. Haga el empotramiento de TIE MAX con la parte inferior de la rosca coincidente con la parte superior del concreto para
asegurar las 7 pulgadas requeridas para el empotramiento.
3. Vierta el concreto. (El perno Exterior TIE MAX puede ser colocado durante el vertimiento). Inserte el perno TIE MAX
hasta la parte inferior de la rosca con 2 pulgadas de separación y termine el vertimiento.
Reposicionamiento
En caso de reposicionamiento después que el concreto ha sido colocado, use una BARRA TIE MAX de 10-1/2 pulgadas de
largo y 5/8 pulgadas de diámetro, instálelo con pegamento adhesivo POWERS POWER BOND siguiendo todas las
instrucciones del fabricante. Vea los detalles en la próxima página.
1. Cuando la estructura de madera este en su lugar, asegure adecuadamente la arandela cuadrada a la placa inferior con
una tuerca hexagonal de 5/8” TIE MAX.
2. Instale un acople reductor de 5/8”-½” TIE MAX en un extremo de la varilla roscada de TIE MAX, el otro extremo del
reductor será acoplado al perno empotrado de TIE MAX. Taladre agujeros en la placa superior o en la placa base si son 2 o
mas pisos e inserte la varilla a través de la placa superior. Hale hacia abajo la varilla hasta que tope con el perno
empotrado de TIE MAX. Enrosque hacia abajo el acople. (Use un acople de 5/8”-5/8” si usa una varilla de 5/8” de diámetro)
3. Seleccione la varilla roscada de acuerdo con el largo suficiente para colocar los acoples arriba o abajo de las placas
superiores o inferiores. Haga topar los extremos de las varillas, centre el acople.
1. Coloque la arandela de acero TIE MAX en la varilla roscada arriba de la placa superior. Vea la tabla 3-A o 3-B de la
página de Referencia Rápida TIE MAX.
3. Apriete la tuerca para asegurar la arandela y la tensión de la varilla. El sistema TIE MAX no requiere una cantidad
específica de torque, la finalidad de TIE MAX es la resistencia al levantamiento, no la post tensión.
TIE MAX es un Sistema de Soporte Estructural. Todos los componentes deben de ser fabricación deTIE MAX.
TIE MAX STUD
Aplicación del Reposicionamiento
Use solamente pegamento aprobado y suministrado por Fastening Specialists, Inc.
7. Inserte la barra TIE MAX con movimiento rotatorio (para asegurar una total penetración del pegamento en la rosca)
hasta que la barra tope con el fondo del agujero.
Nota: si el pegamento no aparece por encima del agujero cuando inserte la barra TIE MAX, remueva la barra, aplique
mas pegamento al agujero, y reinserte la barra TIE MAX con movimiento rotatorio.
8. Deje secar el pegamento de acuerdo a las instrucciones del fabricante antes de aplicar cualquier carga.
TIE MAX es un Sistema de Soporte Estructural. Todos los componentes deben ser fabricación de TIE MAX
Most Widely Accepted and Trusted
0
DIVISION: 03 00 00—CONCRETE
SECTION: 03 16 00—CONCRETE ANCHORS
DIVISION: 04 00 00—MASONRY
SECTION: 04 05 19.16—MASONRY ANCHORS
DIVISION: 06 00 00—WOOD, PLASTICS AND COMPOSITES
SECTION: 06 05 23—WOOD, PLASTIC, AND COMPOSITE FASTENINGS
REPORT HOLDER:
EVALUATION SUBJECT:
TIE MAX ANCHOR BOLTS AND CONTINUOUS ROD TIE-DOWN RUN (CRTR)
ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically
addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use.
There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this
report, or as to any product covered by the report.
www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council ®
FASTENING SPECIALISTS, INC. 3.3.3 TIE MAX Hex Nuts: The TIE MAX hex nuts have
1 5
nominal diameters of /2 and /8 inch.
EVALUATION SUBJECT: 3.3.4 TIE MAX Couplers: The TIE MAX hex couplers
1 5
have nominal diameters of /2 and /8 inch on each end. A
1
TIE MAX ANCHOR BOLTS AND CONTINUOUS ROD coupler reducer is also available with /2 inch (12.7 mm) on
5
TIE-DOWN RUN (CRTR) one end and /8 inch (15.9 mm) on the other end.
4.0 DESIGN AND INSTALLATION
1.0 EVALUATION SCOPE
4.1 Installation:
Compliance with the following codes: The TIE MAX Anchor Bolts and CRTR must be installed
® in accordance with this evaluation report and the
2012 and 2009 International Building Code (IBC)
®
manufacturer’s published installation instructions. For each
2012 and 2009 International Residential Code (IRC) installation, all products must either be zinc-coated or
Properties evaluated: uncoated, due to TIE MAX nuts and TIE MAX couplers
being tapped oversized for applications of zinc coatings. In
Structural the event of a conflict between this report and the
2.0 USES manufacturer’s published installation instructions, the more
restrictive condition governs.
The TIE MAX anchor bolts and continuous rod tie-down 4.2 Design:
runs (CRTRs), which include TIE MAX threaded rods, TIE
MAX washers, TIE MAX hex nuts, and TIE MAX threaded The allowable (ASD) design loads for the TIE MAX anchor
rod couplers, are used to resist wind uplift loads applied at bolts are given in Tables 1 and 2 for embedment in,
the top of wood light-frame walls. Each CRTR provides a respectively, concrete and reinforced masonry. The
continuous load path from the top of the CRTR to a TIE allowable (ASD) design loads for the CRTR are listed in
MAX anchor bolt, which transfers the wind uplift loads into Tables 3 and 4.
a concrete or masonry foundation. 5.0 CONDITIONS OF USE
3.0 DESCRIPTION The TIE MAX anchors and CRTRs described in this report
comply with, or are suitable alternatives to what is
3.1 General: specified in, those codes listed in Section 1.0 of this report,
Specifications for each product are covered under TIE subject to the following conditions:
MAX’s approved quality documentation. Each product is 5.1 The contribution of wood shrinkage, wood
available with and without a zinc coating. The CRTRs deformation under load, and fastener slip, to the
include the following components: TIE MAX threaded rods, overall deflection of the wall in which the CRTRs are
TIE MAX washers, TIE MAX hex nuts, and TIE MAX installed, must be analyzed by a registered design
threaded rod couplers. professional.
ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed
as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as
to any finding or other matter in this report, or as to any product covered by the report.
Copyright © 2018 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 5
ESR-2328 | Most Widely Accepted and Trusted Page 2 of 5
5.2 The tabulated allowable loads noted in this report are 5.9 The use of the CRTRs in contact with chemically
obtained from calculations on the individual treated wood is subject to the approval of the code
components making up the CRTR. Other variables official, since the effects of corrosion of metal in
that may further limit capacities, such as anchorage contact with chemically treated wood, on the
strength in tension or shear, and stresses within the structural performance of the components, are
wood or steel members of the wall in which the CRTR outside the scope of the report.
is installed, must be analyzed by the registered
5.10 Exterior use applications, such as use that allows
design professional.
exposure to moisture, are outside the scope of this
5.3 When using the basic load combinations in report.
accordance with IBC Section 1605.3.1, the tabulated
allowable loads for the CRTR must not be increased 5.11 Installation of the CRTRs must be limited to dry
for wind or seismic loading. When using the alternate interior locations.
basic load combinations in IBC Section 1605.3.2 that 5.12 No further increase in duration of load for wind
include wind or earthquake loads, the tabulated loading is allowed for the use of the CRTR.
ASD loads for the CRTR must not be increased by
1
33 /3 percent, nor shall the alternative basic load 5.13 Drawings and design details verifying compliance with
combinations be reduced by a factor of 0.75. this report must be submitted to the code official for
approval. Drawings and calculations must be
5.4 The tabulated allowable CRTR tension (uplift) loads prepared by a registered design professional when
and corresponding elongations are not intended to required by the statutes of the jurisdiction in which the
represent the capacity or deflection of the framing project is to be constructed.
systems, or any other portion of the wall in which the
CRTR is installed. 6.0 EVIDENCE SUBMITTED
5.5 Design of the framing systems is the responsibility of 6.1 Data in accordance with the ICC-ES Acceptance
the design professional and must be performed in Criteria for Continuous Rod Tie-down Runs and
accordance with the applicable code, taking into Continuous Rod Tie-down Systems Used to Resist
account all of the design considerations given in Wind Uplift (AC391), dated June 2010 (editorially
Section 4.1 of this report. revised March 2015).
5.6 The design of framing and other elements within 6.2 Data in accordance with ACI 318 (for TIE MAX
the load path is the responsibility of the design Anchors installed in concrete).
professional, and must be performed in accordance 6.3 Data in accordance with ACI 530 (for TIE MAX
with the applicable code, considering loads, Anchors installed in masonry).
displacements, shrinkage, etc.
7.0 IDENTIFICATION
5.7 The design of wall top plates receiving uplift load and
distributing it through the CRTR must take into 7.1 The TIE MAX anchor bolts, steel nuts, threaded
account both deflection and strength limit states, rods, and threaded rod couplers are identified by
including combined axial and flexural stress for cases the name of the report holder (Fastening
where the wood top plate(s) also acts as a drag strut Specialists, Inc.), the product name, and the
or collector, and must also take into account evaluation report number (ESR-2328).
geometric compatibility. 7.2 The report holder’s contact information is the
5.8 A positive method to resist torsional rotation and following:
cross-grain flexure of the top plates due to offsets FASTENING SPECIALISTS, INC.
between the point of load application (e.g., hurricane 726 CENTRAL FLORIDA PARKWAY
ties at the sides of the top plates) and load ORLANDO, FLORIDA 32824
resistance (e.g., anchors at the center of the top (407) 888-9099
plate), must be provided where such conditions exist; www.tiemax.com
and calculations in accordance with principles of
mechanics must be used to determine the demand on
connections used to resist top plate torsion.
ESR-2328 | Most Widely Accepted and Trusted Page 3 of 5
MINIMUM SPECIFIED
CONCRETE MINIMUM MINIMUM EDGE ALLOWABLE UPLIFT
/8″ TIE MAX
5
COMPRESSIVE EMBEDMENT (in.) DISTANCE (in.) LOAD (lbf)
ANCHOR BOLTS STRENGTH (psi)
(CAST IN PLACE)
7 2 5,480
2,500
7 7 6,140
For SI: 1 in. = 25.4 mm, 1 lbf = 4.5 N, 1 psi = 6.9 kPa.
Notes:
1. The minimum concrete thickness must be 10 inches.
2. Installations involving Seismic Design Categories C, D, E, and F listed in ACI 318 Section D.3.3 are beyond the scope of this report.
3. Allowable design loads calculated for use in regions of concrete members where analysis indicates no cracking at service loads according
to ACI 318 Section D.5.2.6.
4. The distance from the center of the anchor to all other edges must be a minimum of 10.5 inches.
5. Minimum spacing between anchors must be 21 inches to act as a single fastener according to ACI318 Section D.1.
6. The allowable uplift values are based on calculations in accordance with Appendix D of AC318 divided by a factor of 1.6 in order to take
into account the 1.6W load combination. The design wind load (W) must be less than the tabulated values.
7. The anchors must not be torqued (finger tightened).
5
/8″ TIE MAX MINIMUM MINIMUM EDGE MINIMUM END ALLOWABLE UPLIFT
ANCHOR BOLTS EMBEDMENT (in) DISTANCE (in.) DISTANCE (in.) LOAD (lbf)
(CAST IN PLACE) 7 4 12 2,210
For SI: 1 in. = 25.4 mm, 1 lbf = 4.5 N, 1 psi = 6.9 kPa.
Notes:
1. Allowable uplift loads are for pullout from grouted reinforced masonry with minimum specified compressive strength of 2,000 psi.
2. Masonry units must have a minimum width of 8 inches.
3. Per ACI 530 Section 2.1.4.2.2.1, the projected areas of adjacent bolts must not overlap.
www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council ®
DIVISION: 03 00 00—CONCRETE
Section: 03 16 00—Concrete Anchors
DIVISION: 04 00 00—MASONRY
Section: 04 05 19.16—Masonry Anchors
REPORT HOLDER:
EVALUATION SUBJECT:
TIE MAX ANCHOR BOLTS AND CONTINUOUS ROD TIE-DOWN RUN (CRTR)
ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed
as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as
to any finding or other matter in this report, or as to any product covered by the report.
Copyright © 2018 ICC Evaluation Service, LLC. All rights reserved. Page 5 of 5
TYPICAL TRUSS
TIE MAX
----�----i"h-'i'-'<_W/ TYP 1' EMBEDMENT
MASONRY BOND BEAM
(MIN. REQUIREMENTS:
2000 psf rROUT &
1-#5 CONT. REBAR)
• •
TIE MAX TYP. BONO BEAM
N.T.S
TIE MAX ROD
TIE MAX COUPLER ROD ENDS MUST ENGAGE
ONE FOURTH OF THE COUPLER
MINIMUM, TYP .
TIE �AX
W/ TIP 1' EMBEOMENT
• •
TIE MAX TYP. CONCRETE LIN TEL BEAM
N.T.S
TIE MAX
TYP WALL STUD ROD
.. •.
SOLE PLATE
TIE MAX 5/8" to 1 /2"
COUPLER, T'YP. U.O.N•
2,2,1/8" m
WASHER & NUT
TYP. AT SOLE PLATE, U.O.N.
5/8" TIE MAX ROD
FTG, TYP.
5/8" TIE �AX
EMBED
• .,, . "'
<i
.
2'2,1/8" TM WASHER
2500 psi CONCRETE TYP. AT SOLE PLA� U.O.N.
x-•-x--x-x�
x--�-x�
x�x
.
..
4
4
<1 4
q
• 4
<1
STRAP OR CLIP
BY OTHERS, TYP.
Blacking
<1
1' max.
_____________________
Plan Name:___________________________________
End Date:
The following information must be provided to complete the TIE MAX Layout. Please
_____________________ send a completed copy of this form with each set of plans.
Designer:
Check List
_____________________