0% found this document useful (0 votes)
10 views2 pages

Solartac v001

SolarTAC is an advanced insulation and waterproofing coating designed to reduce interior temperatures and energy costs for buildings by reflecting radiant energy. It is suitable for various substrates and offers features like anti-mould properties and easy application. The product requires proper surface preparation and can be applied using multiple methods, with specific coverage rates depending on the surface type.

Uploaded by

solowhite20
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
10 views2 pages

Solartac v001

SolarTAC is an advanced insulation and waterproofing coating designed to reduce interior temperatures and energy costs for buildings by reflecting radiant energy. It is suitable for various substrates and offers features like anti-mould properties and easy application. The product requires proper surface preparation and can be applied using multiple methods, with specific coverage rates depending on the surface type.

Uploaded by

solowhite20
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

SolarTAC page 1 of 2

Insulation and waterproofing coating

SolarTAC is a cost-effective heat-shielding coating Technical data


that uses advanced insulation technology to reduce Physical properties Value
the interior temperature of buildings. SolarTAC is Elongation at break 260 %
specially formulated with fine spherical particles that Tensile strength 3,80 MPa
minimise surface temperature on roofs and walls by Adhesion strength 1,36 N/mm2
reflecting a large percentage of the radiant energy
Crack Bridging
before it penetrates the building. This lowers the interior Method A No crack within 2 mm
temperature and reduces energy costs for cooling Method B No crack after 10 cycles

the building. Hardness Shore A 65


Water penetration No water penetration
Fields of application UV Exposure 2000 hours No disintegration, cracks,
• SolarTAC is ideal for roofs and walls in both commercial and blisters, peeling or swelling.
residential buildings. Thermal Conductivity 0,09 W/m°K
• SolarTAC can be applied to substrates such as concrete, render, Heat Reflectance >99%* >99%+
aluminium, steel, plaster, sheet, masonry, brick, wood, ect.
Emittance >0,89* 0,88+

Features Specifications are subject to change without notification. Results shown are typical but
reflect test procedures used. Actual field performance will depend on installation methods
• Easy to apply, non toxic and environmentally friendly and site conditions.
• Reduces radiant heat in dwelling * Tested with SolarTAC Brown
• Reduces energy consumption by cooling the building +
Tested with SolarTAC Green
• Has anti-mould and anti-fungal properties
• Electrometric qualities

continued overleaf...
Coverage
Flat Roofs
500 micron dry film thickness i.e. 1,1 m2 / litre.
Pitched Roofs
370 micron dry film i.e. 1,5 m2 / litre.
Walls (smooth)
250 micron dry film i.e. 2,2 m2 / litre.
version 001-201203

Disclaimer: The use of this product is beyond the manufacturer’s control and liability is restricted to the replacement
of material proven faulty. The manufacturer is not responsible for any loss or damage arising from incorrect usage.
Specifications are subject to change without prior notice.

Available from Waterproofing Centres countrywide www.waterproofingcentre.co.za


www.waterproofingcentre.co.za

Cape Town Gauteng KwaZulu-Natal Port Elizabeth East London


Tel 021 448 7880 Tel 011 608 0317 Tel 031 569 3963 Tel 041 365 2936 Tel 043 722 5676
Fax 021 448 7897 Fax 011 608 0347 Fax 031 569 1849 Fax 041 365 6475 Fax 043 722 5676

Brackenfell George Margate Nelspruit email


Tel 021 981 8343 Tel 044 874 3905 Tel 039 312 2764 Tel 013 752 4409 assist@
Fax 044 874 3907 Fax 039 312 2673 Fax 013 752 6556 waterproofingcentre.co.za
SolarTAC page 2 of 2

Insulation and waterproofing coating

Surface preparation Packaging


All surfaces must be free from grease, oil and dust. Very smooth 20 litre plastic pail.
surfaces should be roughened for better adhesion.
Shelf life
• Loose rust, moss, lichens, crumbling cement, deteriorated Up to 12 months in unopened containers stored
fibre cement and degraded bituminous substances must be in a cool dry place.
removed either mechanically or chemically.
• Surface faults such as blisters, holes and cracks should be Cleaning
cleaned out, then repaired with a flexible filler. Small hairline Clean all brushes, rollers, trays, buckets and surrounding areas
cracks can be painted with SolarTAC - brush in, allow to dry, with clean water before the product sets.
then repeat until filled or at least sealed.
Health and safety
• Adhesion to porous substrates can be improved by priming
Wash SolarTAC off your body before it dries to
with Davco Primer. This is recommended because these
a tough, water insoluble film. If it gets in eyes, rinse immediately
surfaces can be very weak and consequently when a coating with water for 5 - 10 minutes. If irritation persists, consult a
of SolarTAC is pulled up it actually tears away the surface to doctor. Move to a well ventilated area if nasal discomfort occurs.
which it is bonded. Sealing with Davco Primer greatly reduces Refer to Material Safety Datasheet for further information
this type of potential failure.
• Rusty metal should be cleaned by blasting or other means to
a suitable standard then primed with a Rust Converter. Other
metals should be suitably primed or treated, e.g. for new
galvanising, degreasing, etch or roughen surface
before coating.

Application
• SolarTAC may be applied directly to all common building
substrates, i.e. concrete, render, aluminium, steel, plaster, sheet,
masonry, brick. Some priming may be required depending on
the substrate condition. (Please refer to our expertise.)
• Apply two or more coats to obtain recommended total
thickness by brush, roller, spread bar or air less spray gun. Ideal
application temperature is between 10 - 30°C and relative
humidity 30 - 80% in rapid drying conditions. Mask large areas
into smaller zones to help obtain an even application
and appearance.
• Rinse brushes, ect. frequently in water to prevent drying/
clogging keep containers closed to minimise skin formation.
• In fast drying weather conditions, adhesion to unsealed
absorbent or porous surfaces is significantly improved by
Davco Primer.

version 001-201203

Disclaimer: The use of this product is beyond the manufacturer’s control and liability is restricted to the replacement
of material proven faulty. The manufacturer is not responsible for any loss or damage arising from incorrect usage.
Specifications are subject to change without prior notice.

Available from Waterproofing Centres countrywide www.waterproofingcentre.co.za


www.waterproofingcentre.co.za

Cape Town Gauteng KwaZulu-Natal Port Elizabeth East London


Tel 021 448 7880 Tel 011 608 0317 Tel 031 569 3963 Tel 041 365 2936 Tel 043 722 5676
Fax 021 448 7897 Fax 011 608 0347 Fax 031 569 1849 Fax 041 365 6475 Fax 043 722 5676

Brackenfell George Margate Nelspruit email


Tel 021 981 8343 Tel 044 874 3905 Tel 039 312 2764 Tel 013 752 4409 assist@
Fax 044 874 3907 Fax 039 312 2673 Fax 013 752 6556 waterproofingcentre.co.za

You might also like