Ids 701 Ctruck
Ids 701 Ctruck
Weighing Indicator
User manual
safety instruction
WARNING
set. Calibrate, inspect and fix the the weighing indicator is prohibited by
Non professional staff
WARNING
WARNING
Page 1 of 21
LIST
1. Summary--------------------------------------------------------------------------3
2. Installation------------------------------------------------------------------------4
2.1 Connection between indicator and load cell-----------------------------4
2.2 Connection of interface-------------------------------------------------------4
3. Basic operation-----------------------------------------------------------------6
3.1 Display and key instruction----------------------------------------------------6
3.2 Power on------------------------------------------------------------------------ 8
3.3 Zero function------------------------------------------------------------------- 8
3.4 Print function------------------------------------------------------------------- 8
3.5 Re-print function-------------------------------------------------------------- 8
4.Calibration----------------------------------------------------------------------- 9
4.1 Enter and exit setting-------------------------------------------------------- 9
4.2 Calibration steps-------------------------------------------------------------- 9
4.3 Parameter setting-------------------------------------------------------------12
5. Output data format-----------------------------------------------------------16
6. Maintenance--------------------------------------------------------------------18
Page 2 of 21
1. Summary
Technical parameter
》Stimulating voltage:+5VDC
》A/D converting speed: 15 times/sec
》load capacity: it can connect 4 pcs 350Ω load cell at most
》weight unit: kg.
》Resolution: 3000e
》Interval: 1/2/5/10/20/50
》Display: 6-digits LED,word height: 20.3mm
》key: ON/OFF ZERO PRINT RE-PRINT
》Interface:RS232C Baud rate optional 1200/2400/4800/9600
》Ambient temperature: -10~40℃
》Storage temperature: -20~+60℃
》power: AC220
Page 3 of 21
Page 4 of 21
5 4 3 2 1
9 8 7 6
Page 5 of 21
3. Basic operation
Page 6 of 21
Kg Weight unit kg
。 Decimal point
Page 7 of 21
Key’s function
Key symbol Key name Key function
3.2 Power on
Power on and indicator perform self-checking and go to weighing
mode.
3.3 Zero setting
Within zero range, press “zero”, indicator weighing is cleared. When
Indicator is not stable, zero is unworkable.
Page 8 of 21
Enter
Up
Left
Page 9 of 21
Page 10 of 21
Page 11 of 21
C12
Upper/lower C13 You can set it within the max.
limit alarm Upper limit alarm capacity limit
value
Page 12 of 21
C14
Lower limit alarm
value
Inner Code C15 At setting function mode, after
display Check inner code directly enter C15,indicator will
show inner code
C16 Enter C16, you can direct to set
Date the current date, from left to right:
year/month/day
Date and time
C17 Enter C16, you can direct to set
Time the current date, from left to right:
year/month/day
option:0= Close serial interface
data output
1= Continuous sending, connect
C18
big display
Serial interface
2=print method, connect printer.
Communication data output
3= Command request method ,
setting method
connect computer.
4=PC continues to sending
format, connect computer.
C19 option:
Baud rate 0=1200/1=2400/2=4800/3=9600
option:0= close manually zero setting
C20
1=±1% max capacity
Manually zero
2=±2% max capacity
Zero range range
4=±4% max capacity
C21 option:0= no initial zero
Initical zero range 1=±1% max capacity
Page 13 of 21
Page 14 of 21
2= slow
option:1=1d
2=2d
C27
5=5d
Standstill range
10=10d
Note: d=division
Digital filter C28 option:0= close dynamic filter
Dynamic filter 1=1 digital filter strength
Instruction : 2=2 digital filter strength
Dynamic filter is 3=3 digital filter strength
collecting the data 4=4 digital filter strength
filter before loaded 5=5 digital filter strength
weight stable. 6=6 digital filter strength
When loaded Note:Pls setting dynamic filter
weight easily strength carefully, the No. is
shaking (for bigger, more stable. if the
example animal) , loaded weight shake not too
you can set this much. The setting is less
filter to make than 3
weight display
more stable
C29 option:0=close noise filter
Noise filter 1=1 digital filter strength
2=2 digital filter strength
3=3 digital filter strength
C30 C30=0 yy.mm.dd
Print time and date C30=1 mm.dd.yy
C30=2 dd.mm.yy
C30=3 yy.mm.dd
Page 15 of 21
State A
Bits0,1,2
0 1 2 Decimal point position
1 0 0 XXXXXX0
0 1 0 XXXXXXX
1 1 0 XXXXX.X
0 0 1 XXXX.XX
1 0 1 XXX.XXX
Bits3,4 Division
0 1 X1
1 0 X2
State B
BitsS function
Bits0 gross=0, net=1
Bits1 symbol:positive =0,negative =1
Bits2 overload(or lower zero)=1
Bits3 dynamic=1
Page 16 of 21
State C
Bit2 Bit1 Bit0 unit
0 0 0 Kg or lb
0 0 1 g
0 1 0 t
Bit 3 printing=1
Extend
Bit 4
display=1
Bit 5 Constant 1
Bit 6 Constant 0
5.2 Print output format
Date: 12.09.01
Time: 16:08:34
Gross 2800kg
Page 17 of 21
6. Maintenance
6.1 Regular Error and maintain method
Error Reason instruction Solution
1. the loaded weight 1.decrease loaded weight
excess overload 2. check load cell
range of max. capacity connection
Display 2. wrong connection 3. checking load cell :
UUUUUU with load cell or no check input and output
connection with it. resistance to judge it is
3. load cell good or not.
unworkable
1. calibration is no 1. check scale is resisted
good or not, foot is kept level
2 、 cell single line is or not.
connect a wrong line. 2. check load cell
Display nnnnnn 3、the cell is bad. connection.
3. checking load cell :
check input and output
resistance to judge it is
good or not.
during calibration, no Input the correct weight
input added weight or
ERR1
input weight exceed
max capacity.
Page 18 of 21
Page 19 of 21
setting.
Note:Pls. do not restore default parameter easily if you are not
professional and have not scale calibration.
Page 20 of 21
Page 21 of 21