This document serves as a selection guide for Childers® products, specifically mastics, coatings, adhesives, and sealants used in the thermal insulation industry. It details various products suitable for different insulation types and operating conditions, including their applications and performance characteristics. General recommendations for product selection and application techniques are also provided to ensure proper usage.

Uploaded by

7ppyhx2b2h
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
117 views8 pages

Childers Selection Guide

This document serves as a selection guide for Childers® products, specifically mastics, coatings, adhesives, and sealants used in the thermal insulation industry. It details various products suitable for different insulation types and operating conditions, including their applications and performance characteristics. General recommendations for product selection and application techniques are also provided to ensure proper usage.

Uploaded by

7ppyhx2b2h
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Guide to

Mastics,
Coatings,
Adhesives
& Sealants
for the
Thermal
Insulation
Industry

®
Selection Guide to Childers® Products
Mastics, Coatings, Adhesives and Sealants
Weather Barrier Coatings
“Breather” type for above ambient temperatures and Vapor Barrier type for below ambient temperatures.

GLASS FIBER/MINERAL WOOL/CELLULAR GLASS/POLYURETHANE/POLYISOCYANURATE/PHENOLIC FOAM INSULATIONS


Pipings, Fittings, Vessels and Equipment Operating at:
Air-Conditioning and
Below Ambient Above Ambient Dual-Temperature Ducts* Warm Air Ducts
OUTDOOR AND HEAVY-DUTY INDOOR
Encacel® X / V CP-40/45 Ak-Cryl™ CP-9 Encacel® X/V CP-40/45 Ak-Cryl™ CP-9
Chil-Pruf™ CP-22/24 Vi-Cryl CP-10/11
®
Chil-Perm WB CP-35
®
Vi-Cryl® CP-10/11
Chil-Pruf™ CP-22/24
INDOOR
Chil-Perm® CP-30 Low Odor Ak-Cryl™ CP-9 Chil-Perm® WB CP-35 Ak-Cryl™ CP-9
Chil-Perm WB CP-35
®
Vi-Cryl CP-10/11
®
Vapor Retarder Coating CP-34 Vi-Cryl® CP-10/11
Vapor Retarder Coating CP-34 Chil-Seal® CP-50AMV1/ Chil-Seal® CP-50AMV1/ Chil-Seal® CP-50AMV1/
CP-50AHV2 CP-50AHV2** CP-50AHV2
*Ak-Cryl™ CP-9 and Vi-Cryl ® CP-10/11 may also be used in most sloped dual temperature duct applications where insulation facing provides a vapor barrier.
**Chil-Seal ® CP-50AMV1 and CP-50AHV2 may be used on dual temperature duct applications where insulation facing provides a vapor barrier.

EXTRUDED AND EXPANDED POLYSTYRENE INSULATIONS


Pipings, Fittings, Vessels and Equipment Operating at:
Air-Conditioning and
Below Ambient Above Ambient Dual-Temperature Ducts* Warm Air Ducts
OUTDOOR AND HEAVY-DUTY INDOOR
Chil-Perm WB CP-35
®
Ak-Cryl™ CP-9 Chil-Perm® WB CP-35 Ak-Cryl™ CP-9
Vapor Retarder Coating CP-34 Vi-Cryl CP-10/11
®
Vi-Cryl® CP-10/11
INDOOR
Chil-Perm WB CP-35
®
Ak-Cryl™ CP-9 Chil-Perm® WB CP-35 Ak-Cryl™ CP-9
Vapor Retarder Coating CP-34 Vi-Cryl CP-10/11
®
Vapor Retarder Coating CP-34 Vi-Cryl® CP-10/11
Chil-Seal® CP-50AMV1/ Chil-Seal® CP-50AMV1/
CP-50AHV2 CP-50AHV2
*Ak-Cryl™ CP-9 and Vi-Cryl® CP-10/11 may also be used in most sloped dual temperature duct applications where insulation facing provides a vapor barrier.

CALCIUM SILICATE AND PERLITE INSULATIONS


Pipings, Fittings, Vessels and Equipment Operating Above Ambient
Normal Service Heavy-Duty Service NOTE: If insulating cements are used, the cement must be
completely dry. Prime the dry cement or dusty surfaces, such
OUTDOOR as calcium silicate, with Childers® Chil-Seal® CP-50AMV1
Ak-Cryl™ CP-9 Ak-Cryl™ CP-9 diluted 50% with water and allow to completely dry prior to the
application of either Ak-Cryl™ CP-9 or Vi-Cryl® CP-10/11 weather
Vi-Cryl CP-10/11
®
Vi-Cryl® CP-10/11 barrier coatings.
Chil-Brate™ CP-25 Chil-Brate™ CP-25
INDOOR
Chil-Seal CP-50AMV1/
®
Ak-Cryl™ CP-9
CP-50AHV2
Vi-Cryl® CP-10/11

2
Adhesives and Sealants
GLASS FIBER AND MINERAL WOOL INSULATIONS
Sealing joints of piping, Sealing Laps of ASJ,
Adhering insulation to tanks, Adhering insulation to tanks, vessels, Lagging/Adhering FSK Vapor Barrier
vessels, equipment, ducts itself for piping, fittings equipment Canvas / Glass Cloth Facings
Chil-Stix® FRN CP-82 (Brush) Chil-Stix® FRN CP-82 (Brush) Not Applicable Chil-Seal® CP-50AMV1/ Chil-Stix® FRN CP-82
Chil-Stix® Clear CP-85 (Brush) Chil-Stix® Clear CP-85 (Brush) CP-50AHV2 Chil-Stix® Clear CP-85
Chil-Spray® NF CP-89 (Spray)
Chil-Grip™ CP-124

PHENOLIC FOAM, POLYURETHANE, AND POLYISOCYANURATE INSULATIONS


Sealing joints of piping, Sealing Laps of ASJ,
Adhering insulation to tanks, Adhering insulation to tanks, vessels, Lagging/Adhering FSK Vapor Barrier
vessels, equipment, ducts itself for piping, fittings equipment Canvas / Glass Cloth Facings
Chil-Stix® FRN CP-82 (Brush) Chil-Rene™ CP-96 (Trowel) Chil-Joint® CP-70** Chil-Seal® CP-50AMV1/ Chil-Stix® FRN CP-82
Chil-Stix® Clear CP-85 (Brush) Chil-Byl® CP-76 CP-50AHV2 Chil-Stix® Clear CP-85
Chil-Spray® NF CP-89 (Spray)
Chil-Rene™ CP-96 (Trowel)
Chil-Grip™ CP-124

EXTRUDED AND EXPANDED POLYSTYRENE INSULATIONS


Sealing joints of piping, Sealing Laps of ASJ,
Adhering insulation to tanks, Adhering insulation to tanks, vessels, Lagging/Adhering FSK Vapor Barrier
vessels, equipment, ducts itself for piping, fittings equipment Canvas / Glass Cloth Facings
Chil-Rene™ CP-96 (Trowel)* Chil-Rene™ CP-96 (Trowel)* Chil-Joint® CP-70 Chil-Seal® CP-50AMV1/ Inquire
CP-50AHV2
*After applying Chil-Rene™ CP-96 solvent must be allowed to flash off before bonding.

CELLULAR GLASS INSULATIONS


Sealing joints of piping, Sealing Laps of ASJ,
Adhering insulation to tanks, Adhering insulation to tanks, vessels, Lagging/Adhering FSK Vapor Barrier
vessels, equipment, ducts itself for piping, fittings equipment Canvas / Glass Cloth Facings
Inquire Inquire Chil-Joint® CP-70** Not Applicable Chil-Stix® FRN CP-82
Chil-Byl® CP-76 Chil-Stix® Clear CP-85

CALCIUM SILICATE AND EXPANDED PERLITE INSULATIONS


Sealing joints of piping, Sealing Laps of ASJ,
Adhering insulation to tanks, Adhering insulation to tanks, vessels, Lagging/Adhering FSK Vapor Barrier
vessels, equipment, ducts itself for piping, fittings equipment Canvas / Glass Cloth Facings
Fibrous Adhesive CP-97 Fibrous Adhesive CP-97 Not Applicable Chil-Seal® CP-50AMV1/ Not Applicable
CP-50AHV2

** Not to be used underneath solvent-based vapor barrier coatings if minor surface discoloration would be objectionable.

General Information
1. Recommendations made in this selection and specification guide to Childers® Mastics, Coatings, Adhesives and Sealants are general in nature
and scope. Please refer to the individual Product Data Sheet for complete product information and recommendations to assure proper product
selection.
2. Adhesive use should be predicated upon the user testing the suitability of the adhesive for the particular insulation and application desired.
3. Weather barrier coatings, when applied outdoors, should always be applied over sloped horizontal surfaces to prevent ponding water. Industry
experience has demonstrated that all weather barrier coatings may blister when applied over skinned extruded polystyrene board. Also, a white
color should always be used.

3
Insulation Volatile Product
Name General Description Application Component Application
Childers® Weatherproofing coating/mastic that is tough, durable, fire-resistive. Hot service Water Trowel
CP-9 Used as mechanical protection and weatherproofing of thermal and dual Brush
Ak-Cryl™ insulations, indoors and outdoors, for piping, tanks, fittings, vessels, temperature Spray
equipment, and other irregularly shaped objects.

Childers® High performance weather barrier mastic/coating that is tough, Hot service Water Trowel
CP-10/11 durable and fire-resistive. Used as weatherproofing and mechanical and dual Brush
Vi-Cryl® protection of thermal insulations, indoors and outdoors, for piping, temperature Spray
tanks, fittings, vessels, equipment, and other irregularly shaped
objects.

Childers® Asphalt-based combustible fibrated cutback vapor barrier and weather Cold service Solvent Trowel
CP-22/24 barrier insulation coating. The cured film forms a highly vapor and dual Brush
Chil-Pruf™ retardant, tough, durable, and well bonded finish. Used over temperature Spray
insulations (except polystyrene) to protect piping, tanks, fittings,
and vessels. Also protects insulation on underground piping.

Childers® Water-based fibrated asphalt emulsion breathing weather barrier Hot service Water Trowel
CP-25 insulation coating. Fire retardant, tough, and durable. Protects Spray
Chil-Brate™ against corrosives, chemical dusts, fumes, fogs, and moisture.
Used over all types of insulations to protect piping, fittings, tanks,
and vessels. Not recommended for ponded water areas.

Childers® Extremely effective vapor barrier coating for low temperature interior Cold service Solvent Trowel
CP-30 application. Combustible. Provides a tough, flexible, fire resistant, dry Brush
Low Odor film resistant to most acids and alkalis. Used over low temperature
insulations (except polystyrene) for pipings, fittings, tanks.
Chil-Perm®

Childers® Water-based vapor retardant coating for use over ASJ, FRK, FSK and Cold service Water Brush
CP-34 other jacketing and board facings to give a vapor retarding seal at Spray
Vapor Retarder joints, laps and weld pin punctures. For use with insulation on pipes,
vessels, ducts, and equipment operating between 32°F (0°C) and
Coating ambient temperatures.

Childers® A high performance water-based vapor retarder coating for low Cold service Water Trowel
CP-35 temperature interior and exterior applications. Provides a tough, Brush
Chil-Perm® WB flexible, dry film. Used over all low temperature insulations for Spray
piping, fittings, tanks. Not recommended for ponded water areas.

Childers® Trowelable elastomeric combustible vapor barrier coating. Fire Cold service Solvent Trowel
CP-40 resistant dry film with excellent adhesion and flexibility. The ultimate and dual
Encacel® X vapor barrier coating for interior and exterior applications. Used over temperature
low temperature insulations (except polystyrene) for spheres, tanks,
piping, and fittings.

Childers® Sprayable elastomeric combustible vapor barrier coating. Fire resistant Cold service Solvent Brush
CP-45 dry film with excellent adhesion and flexibility. The ultimate vapor and dual Spray
Encacel® V barrier coating for interior and exterior applications. Used over low temperature
temperature insulations (except polystyrene) for spheres, tanks, piping,
and fittings. Also used for exterior sprayed polyurethane applications.

Childers® Combination coating and lagging adhesive. Water-based and fire- Hot service Water Brush
CP-50A MV1 resistive when dry. Used to adhere fabrics (canvas and brattice cloth) and dual Spray
Chil-Seal® to round and rectangular insulated ductwork and to adhere laps of temperature
fabrics to themselves and underlying pipe insulations.

Childers® A high viscosity combination coating and lagging adhesive. Water- Hot service Water Trowel
CP-50A HV2 based and fire-resistive when dry. Can be applied to overhead and and dual Brush
Chil-Seal® vertical surfaces. Used to adhere fabrics (canvas and brattice cloth) temperature Spray
to round and rectangular insulated ductwork and to adhere laps of
fabrics to themselves and underlying pipe insulations.

4
Service Reinforcing
Color Coverage Temperature Perm Rating Mesh Clean-up Specification Met
White, 6 U.S. Gal./ -40°F to 180°F Greater than Chil-Glas® #10 Water U.L. Classified and tested according to
Special Colors 100 sq. ft. (-40°C to 82°C) 1.0 Perm for ASTM E-84. Meets NFPA Standard 90-A
Available (.063" DFT) 1/16" dry film and 90-B 25/50 requirements.
(2.4 l/sq. m) (Breather)
(.16 cm DFT)

White, 6 U.S. Gal./ -40°F to 180°F Greater than Chil-Glas® #10 Water U.L. Classified and tested according to
Gray, 100 sq. ft. (-40°C to 82°C) 1.0 Perm for ASTM E-84. Meets NFPA Standard 90-A
Black, (.063" DFT) 1/16" dry film and 90-B 25/50 requirements.
Special Colors (2.4 l/sq. m) (Breather)
Available (.16 cm DFT)

Black 10-13 U.S. Gal./ -60°F to 325°F .02 to .03 Perms Chil-Glas® #5 Mineral Tested in accordance with ASTM E-84.
100 sq. ft. (-51°C to 163°C) (Procedure E) Chil-Glas® #10 Spirits or
(4-5.2 l/sq. m) at .094" film Chlorinated
Varies with substrate thickness Solvents
and membrane
Black 15 U.S. Gal./ -20°F to 200°F Chil-Glas® #5 Water
100 sq. ft. (-29°C to 93°C) Chil-Glas® #10
(6.15 l/sq. m)
Varies with substrate
and membrane
White 4 U.S. Gal./ -40°F to 190°F Less than .02 Chil-Glas® #10 Xylene or U.L. Classified and tested according to
100 sq. ft. (-40°C to 88°C) Perms at .02" Chlorinated ASTM E-84. Meets NFPA Standard
(.020" DFT) film thickness Solvents 90-A and 90-B 25/50 requirements.
(1.6 l/sq. m) Qualification under U.S. Coast Guard
(.096 cm DFT) specification 164.012.

White 4 U.S. Gal./ -20°F to 180°F .08 Perms Chil-Glas® #10 Water Tested in accordance with ASTM E-84.
100 sq. ft. (-29°C to 82°C) at .045" film Meets NFPA Standard 90-A and 90-B
(.038" DFT) thickness 25/50 requirements when used to seal
(1.6 l/sq. m) laps in vapor barrier facings.
(.096 cm DFT)

White 4 U.S. Gal./ -20°F to 190°F Less than .08 Chil-Glas® #10 Water Tested in accordance with ASTM E-84.
100 sq. ft. (-29°C to 88°C) Perms at .055" Meets NFPA Standard 90-A and 90-B
(.038" DFT) film thickness 25/50 requirements.
(1.6 l/sq. m)
(.096 cm DFT)

White, 5 U.S. Gal./ -40°F to 190°F Less than .06 Chil-Glas® #10 Xylene or U.L. Classified and tested according to
Gray, 100 sq. ft. (-40°C to 88°C) Perms at .035" Chlorinated ASTM E-84. Meets NFPA Standard
Special Colors (.038" DFT) film thickness Solvents 90-A and 90-B 25/50 requirements.
Available (2.4 l/sq. m) Qualification under U.S. Coast Guard
(.096 cm DFT) specification 164.012.

White, 6 U.S. Gal./ -40°F to 190°F Less than .07 Chil-Glas® #10 Xylene or U.L. Classified and tested according to
Gray, 100 sq. ft. (-40°C to 88°C) Perms at .027" Chlorinated ASTM E-84. Meets NFPA Standard
Special Colors (.030" DFT) film thickness Solvents 90-A and 90-B 25/50 requirements.
Available (2.4 l/sq. m) Qualification under U.S. Coast Guard
(.08 cm DFT) specification 164.012.

White 1-1.25 U.S. Gal./ -20°F to 180°F 1.0 Perms Canvas, Water Tested in accordance with ASTM E-84.
100 sq. ft. per coat (-29°C to 82°C) Brattice Cloth, Meets NFPA Standard 90-A and 90-B
(.41-.51 l/sq. m) Glass Fiber 25/50 requirements.
on Fabrics

White 1-1.25 U.S. Gal./ -20°F to 180°F 1.0 Perms Canvas, Water U.L. Classified and tested according to
100 sq. ft. per coat (-29°C to 82°C) Brattice Cloth, ASTM E-84. Meets NFPA Standard
(.41-.51 l/sq. m) Glass Fiber 90-A and 90-B 25/50 requirements. MIL
on Fabrics SPEC MIL-A-3316C, Class 1, Grade A.
Qualification under U.S. Coast Guard
specification 164.012.

5
Insulation Volatile Product
Name General Description Application Component Application
Childers® Flexible sealant, flashing compound and vapor seal. Non-shrinking, Cold service, Solvent Trowel
CP-70 skins over, permanently flexible. Used to vapor seal and act as an dual Extrusion
Chil-Joint® expansion joint in joints of cellular glass and cellular plastic temperature,
insulations. some hot
service

Childers® Flexible sealant and elastomeric vapor barrier. Resists ultra violet, Cold service, Solvent Trowel
CP-76 water soak, vibrational stress. Permanently flexible. Used to vapor dual Extrusion
Chil-Byl® seal and act as an expansion joint in joints of cellular glass and temperature,
cellular plastic insulations. Also used as sealant for joints in metal some hot
jacketing and metal curtainwall panels and sheets. service

Childers® High temperature asphalt sealant and coating operating up to 350°F Hot service Solvent Trowel
CP-79 (177°C). Forms a tough, durable, and heavy film. Used as flashing to Spray
Chil-Lastic™ seal boiler settings to prevent air infiltration. Also used in refractory
applications.

Childers® A high strength neoprene contact adhesive. Non-flammable wet, Cold service Solvent Brush
CP-82 fire-resistive dry. Used to bond impermeable surfaces together. Also and hot
Chil-Stix® FRN used to adhere insulations (except polystyrene) to sheet metal and service
ductwork. Adheres laps of vapor barrier facings and jackets.

Childers® Adhesive for flexible blanket insulations, fibrous glass, some plastic Cold service Solvent Brush
CP-85 foams. Flammable. Quick setting, fire-resistive, permanently flexible, and hot
Chil-Stix® Clear quick initial grab. Used to bond impermeable surfaces together. Also service
used to adhere insulations (except polystyrene) to sheet metal and
ductwork.

Childers® Spray adhesive. Non-flammable wet and fire-resistive dry. Sprays Cold service Solvent Spray
CP-89 without misting and has a high coverage rate. Used to bond and some hot
Chil-Spray® NF impermeable surfaces together. Also used to adhere insulations service
(except polystyrene) to sheet metal and ductwork.

Childers® High strength fast grab synthetic rubber and resin adhesive. Cold service Solvent Trowel
CP-96 Flammable. Bonds polystyrene and urethane insulations to themselves and some hot
Chil-Rene™ and other structural surfaces such as aluminum, stainless steel, service
galvanized steel, concrete block, ceramic tile, masonry, drywall,
wood, and gypsum board. Ideal for cold storage applications.

Childers® A sodium silicate-based adhesive of exceptional strength. Non-flammable Hot service Water Trowel
CP-97 wet and totally incombustible dry. Bonds calcium silicate and expanded
Fibrous Adhesive perlite to themselves and to other non-porous surfaces.
Childers® Spray adhesive. Fast tacking, fire-resistive, sprays without misting, Cold service Solvent Spray
CP-124 high coverage rate. Flammable. Used to bond impermeable surfaces and hot
Chil-Grip™ together. Also used to adhere insulations (except polystyrene) to service
sheet metal and ductwork.

6
Service Reinforcing
Color Coverage Temperature Perm Rating Mesh Clean-up Specification Met
Gray For 1" x 1/8" Joint: -100°F to 300°F Too small Mineral
154 Lin. ft./U.S. Gal. (-73°C to 149°C) to measure Spirits or
(12 m/l for through a 1" Chlorinated
2.5 cm x .31 cm) joint x 1/8" Solvents
For 1/8" Beads: wide
1232 Lin. ft./U.S. Gal.
(99 m/l for
.31 cm Bead)

White, For 1" x 1/8" Joint: -100°F to 300°F Too small Mineral Tested according to ASTM E-84. Meets
Gray 154 Lin. ft./U.S. Gal. (-73°C to 149°C) to measure Spirits or NFPA Standard 90-A and 90-B 25/50
(12 m/l for through a 1" Chlorinated requirements.
2.5 cm x .31 cm) joint x 1/8" Solvents
For 1/8" Beads: wide
1232 Lin. ft./U.S. Gal.
(99 m/l for
.31 cm Bead)

Black 8-10 U.S. Gal./ -75°F to 350°F .01 Perms Chil-Glas® #5 Mineral
100 sq. ft. (-59°C to 177°C) Chil-Glas® #10 Spirits or
(3.2-4.1 l/sq. m) Chlorinated
Solvents

Light Tan For Insulation: -30°F to 200°F Chlorinated U.L. Classified and tested according to
150-250 sq. ft./ (-34°C to 93°C) Solvents ASTM E-84. Meets NFPA Standard 90-A
U.S. Gal. and 90-B 25/50 requirements. Meets
(3.6-6.1 sq. m/l) ASTM C-916, Type 1.
For Laps:
600-750 Lin. ft./
U.S. Gal.
(48-60 m/l)

Clear, For Insulation: -20°F to 200°F Xylene or U.L. Classified and tested according to
Amber 200-250 sq. ft./ (-29°C to 93°C) Chlorinated ASTM E-84. Meets NFPA Standard 90-A
U.S. Gal. Solvents and 90-B 25/50 requirements. Meets
(4.9-6.1 sq. m/l) ASTM C-916, Type 4.
For Laps:
500-600 Lin. ft./
U.S. Gal.
(40-48 m/l)

Blue (Applied to metal) -30°F to 200°F Chlorinated U.L. Classified and tested according to
450-600 sq. ft./ (-29°C to 93°C) Solvents ASTM E-84. Meets NFPA Standard 90-A
U.S. Gal. and 90-B 25/50 requirements. Meets
(11-14.7 sq. m/l) ASTM C-916, Type 2.

Light Tan 60 sq. ft./U.S. Gal. -20°F to 180°F Mineral


(1.5 sq. m/l) (-29°C to 82°C) Spirits or
Chlorinated
Solvents

Gray 2.5-3 U.S. Gal./ 40°F to 850°F Water


100 sq. ft. (4°C to 454°C)
(1.02-1.22 l/sq. m)

Red (Applied to metal) -20°F to 200°F Mineral U.L. Classified and tested according to
450-600 sq. ft./ (-29°C to 93°C) Spirits or ASTM E-84. Meets NFPA Standard 90-A
U.S. Gal. Chlorinated and 90-B 25/50 requirements. Meets
(11-14.7 sq. m/l) Solvents ASTM C-916, Type 4.

7
®

Protective Systems
Mastics & Coatings
Adhesives & Sealants

HVAC
Adhesives & Sealants

Specialty Construction Brands, Inc.


1105 S. Frontenac Street
Aurora, IL 60504
Customer Service: 800-231-9541
Fax: 800-942-6856
www.fosterproducts.com

Important: Specialty Construction Brands, Inc. warrants that each of its


products will be manufactured in accordance with the specifications in effect on
the date of manufacture. WE MAKE NO OTHER WARRANTIES AND EXPRESSLY
DISCLAIM ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR
A PARTICULAR PURPOSE. If a product fails to meet this limited warranty,
purchaser’s sole and exclusive remedy is replacement of the product or, at our
option, refund of the purchase price. OUR ACCEPTANCE OF ANY ORDERS FOR
THE PRODUCT IS EXPRESSLY CONDITIONAL UPON PURCHASER’S ASSENT
TO THE TERMS ON THE APPLICABLE INVOICE.

Adequate Tests: The information contained herein we believe is correct to the


best of our knowledge and tests. The recommendations and suggestions herein
are made without guarantee or representation as to results. We recommend
that adequate tests be performed by you to determine if this products meets
all of your requirements. The warranted shelf life of our products is six months
from date of shipment to the original purchaser.

Printed in U.S.A
©2008 Specialty Construction Brands, Inc.
Form #BRO-CSGR0308