See discussions, stats, and author profiles for this publication at: https://www.researchgate.
net/publication/264707598
Experimental study of passive cooling of building facade using phase change
materials to increase thermal comfort in buildings in hot humid areas
Article in International Journal of Energy, Environment and Economics · January 2012
CITATIONS READS
22 1,356
2 authors:
Madhu Mathi M. C. Sundarraja
Vellore Institute of Technology University Thiagarajar College of Engineering
25 PUBLICATIONS 165 CITATIONS 39 PUBLICATIONS 860 CITATIONS
SEE PROFILE SEE PROFILE
All content following this page was uploaded by Madhu Mathi on 29 October 2015.
The user has requested enhancement of the downloaded file.
INTERNATIONAL JOURNAL OF
ENERGY AND ENVIRONMENT
Volume 3, Issue 5, 2012 pp.739-748
Journal homepage: www.IJEE.IEEFoundation.org
Experimental study of passive cooling of building facade
using phase change materials to increase thermal comfort in
buildings in hot humid areas
A. A. Madhumathi1, B. M.C. Sundarraja2
1
Department of Architecture, Thiagarajar College of Engineering, Madurai-15, Tamilnadu, India.
2
Department of Civil Engineering, Thiagarajar College of Engineering, Madurai-15, Tamilnadu, India.
Abstract
Storage of cooler night temperatures using Phase Change Material (PCM) energy storage technique, for
cooling of ambient air during hot day times can be an alternate of current cooling techniques in building
sector. This work presents the results of an experimental set-up to test energy saving potential of phase
change materials with typical construction materials in building facade in Hot-Humid Climatic Regions
in real conditions. The main objective of this research is to demonstrate experimentally that it is possible
to improve the thermal comfort and reduce the energy consumption of a building without substantial
increase in the weight of the construction materials with the inclusion of PCM. This research was
conducted to study and evaluate the performance of the existing materials integrated with Organic PCM
Polyethylene glycol (PEG) E600. This research suggested that the heat gain is significantly reduced
when the PCM is incorporated into the brick (conventional building material).
Copyright © 2012 International Energy and Environment Foundation - All rights reserved.
Keywords: Hot and humid climates; Latent heat storage; Phase change material; Sustainable design;
Technology thermal comfort.
1. Introduction
The worldwide economical and technological development requires higher energy demands and higher
comfort expectations (heating and cooling systems). However, energy sources are limited and related to
harmful gases, which are responsible for climate changes, global warming and environmental problems.
Scientists all over the world are in search of new and renewable energy sources to reduce the CO2
emissions from the combustion of fossil fuels, particularly in areas where low temperature applications
are involved. In an attempt to reduce CO2 emissions (as well as to reduce the cost associated with the
cooling and heating of buildings), various studies based on the use of energy storage materials, which
can absorb thermal energy at one time(day time) and release it at later time(night time), are engaged all
over the World.
The concept of storing heat within the building walls has been around since 1881. The building’s mass
plays an important part in determining the temperature. A heavy building is able to smooth out
temperature peaks by virtue of its mass. The use of thermal mass in shelter dates back to the dawn of
humans, and until recently has been the prevailing strategy for building climate control in hot regions.
Today there is a shift away from traditional construction materials and block building techniques towards
light weight building materials and prefabricated building elements. However, a move to lightweight
ISSN 2076-2895 (Print), ISSN 2076-2909 (Online) ©2012 International Energy & Environment Foundation. All rights reserved.
740 International Journal of Energy and Environment (IJEE), Volume 3, Issue 5, 2012, pp.739-748
construction raises concerns over internal comfort conditions due to lack of thermal storage properties,
resulting in rapid swings of internal temperature.
Optimized selection of building materials for making the external envelop also plays an important role in
achieving thermal comfort in buildings, where thermal comfort is achieved through passive –cooling,
strategies. Many materials and systems currently on the market are designed to keep interiors warm by
virtue of their insulating properties. PCMs are proved to be very effective in light weight buildings, since
they increase their thermal mass.
Phase Change Materials (PCMs) are proposed as a solution to reduce energy demands from buildings by
the addition of PCMs to construction materials as concrete, gypsum or plasterboard panels [1, 2]. Recent
research has looked at the incorporation of organic PCMs into porous building materials, creating
functional and effective building elements which can affect significant energy savings.
The thermal energy storage property of PCMs is based on its capability of latent heat storage, because
large amounts of energy can be stored in a small volume of PCM. Therefore, the material containing
PCMs can absorb and release heat more effectively than conventional building materials [3]. Similarly,
the energy needed to produce the PCMs would only be a fraction of the energy needed to produce blocks,
bricks or concrete with the same heat storage capacity [4]. Its high thermal inertia does not require the
use of thick layers, resulting as a very low invasive technology. Thermal inertia is the degree of slowness
with which the temperature of a body approaches that of its surroundings and which is dependent upon
its absorptivity, its specific heat, its thermal conductivity, its dimensions, and other factors
The utilization of PCM in active and passive solar buildings has been subject to considerable interest
since the first reported application in the 1940s [5]. PCMs store latent heat as the ambient temperature
rises up to the melting point (PCM changes from solid to liquid state) [6]. As the temperature cools
down, the PCM return to solid phase and the latent heat is released. This absorption and release of heat
takes place at a constant temperature, which is ideal to smooth temperature fluctuations. The thermal
improvements in a building due to the inclusion of PCMs depend on the climate, design and orientation
of the construction, but also to the amount and type of PCM [7].
PCM materials can contribute to the energy efficiency of buildings by reducing the peaks in the daily
temperature cycles. It may be possible that mechanical air conditioning is not needed at all; as a
minimum, the energy consumption for air conditioning can be reduced. And this is how it works: as part
of normal overnight ventilation, the warm air in the building is replaced by cold night-time air, which
also reduces the temperature of the building’s solid structures over the course of the night. PCM can
increase the heat capacity of the building, meaning that additional ‘coldness’ can be stored in the
building’s structures. PCM can be integrated into walls, ceilings or facade elements, for example.
2. Comfort temperatures and climatic data for Madurai region
A hot-humid climate is defined as a “region that receives more than 20 inches of annual precipitation”
and either has 3,000 or more hours of 67˚F temperature or 1,500 or more hours of 73 ˚F temperature
during the warmest six months of the year. In this type of climate, the main function of the buildings is to
simply moderate the daytime heating effects of the external air [8].
The air temperature and relative humidity are the important factors in determining the comfort level in
the hot and humid region. The typical climate of the hot and humid region is the high air temperature at
an average of 28˚ Celsius with an average of 80% of relative humidity. These factors have become the
biggest challenge for the architects in designing a passive cooling building. The hot air and high relative
humidity have become very problematic in designing naturally ventilated buildings.
The experimental study area Madurai comes under hot humid climate with maximum average
temperature 35.38˚c and minimum average temperature 24.82˚c (for year 2009-2010) and average
relative humidity 60 %( for year 2009-2010). Since it is like summer all year around, cooling is the main
issue regarding buildings in Madurai. Most of the buildings are built with Reinforced Concrete Slabs
(RCC) as roofing system and Clay tile roofs for a smaller percentage. Moreover, most of these buildings
have no insulation material installed As a result, these buildings act like a sauna, where most of the
building facades are exposed to excessive solar radiations that absorb heat throughout the day. The heat
is then conducted to the inner spaces, thereby creating thermal discomfort for the building occupants.
PCM has never been tested in a hot humid climate like Madurai in India, and thus the potential benefits
remain uncertain, especially for the residential sector. This study investigates the potential of using PCM
for thermal heat storage in building facades in hot humid climates. This integration will likely cause an
ISSN 2076-2895 (Print), ISSN 2076-2909 (Online) ©2012 International Energy & Environment Foundation. All rights reserved.
International Journal of Energy and Environment (IJEE), Volume 3, Issue 5, 2012, pp.739-748 741
increase in heat transfer that will increase heat storage capacity and reduce internal temperature
fluctuations compared with other materials that have been used until today.
Average monthly daily hourly temperature data for a year of June 2009 to May 2010 of Madurai is
obtained from Meteorological department and is shown in Table 1 which will be used for further analysis
and basis for finding the comfort temperatures. The average monthly maximum and minimum
temperatures are obtained is used to calculate the mean temperatures. Mean temperatures are then used to
calculate the comfort temperatures for each month. Adaptive comfort temperature standards allow
occupants to restore comfort when they feel discomfort [9].
Table 1. Temperature data: -Madurai, Tamilnadu, India 2009-10 (in Celsius)
Year Month Maximum Minimum Humidity in %
Highest Mean Lowest Mean 8.30 Hours 17.30 Hours
2009 June 39.6 37.9 24.6 26.2 58 44
July 39.8 37.7 25.2 26.7 53 42
August 39.6 37.0 23.4 25.8 62 51
September 39.6 36.6 23.8 25.8 66 52
October 37.8 35.9 22.8 25.0 65 46
November 33.6 30.8 20.6 23.6 81 75
December 31.8 29.8 20.9 22.7 78 67
2010 January 33.0 31.3 19.8 21.9 75 51
February 37.0 33.5 19.7 22.1 76 39
March 38.8 37.2 19.4 24.1 70 32
April 40.2 38.7 24.4 26.8 66 42
May 41.4 38.2 23.2 27.2 77 64
Source: India Meteorological Department, Chennai-6
Many of the International Standards produced are found to be inadequate for describing the comfort
condition in the tropical climate. The majority of the field studies conducted discovered that the
international set up is either overestimating or underestimating the comfort condition in this climate [10].
This is partly due to the derivation of the standards that are mainly based on the studies conducted in the
moderate environmental condition.
One of the international standards frequently used for indoor climate condition is ISO7730 based on
Fanger’s predicted mean vote (PMV/PPD) equation. The equation of the formula is applied to derive a
numerical value depicting the comfort conditions based on the ASHRAE scale. The air temperature of
30˚ Celsius is considered normal for this climate and the air movement of more than 1 m/s is desirable to
relieve the heat. The outside climate plays a very influential role in thermal comfort perception for a free-
running building. The study by Humphreys and Nicol [11] discovered that the comfort temperatures are
linearly related to the mean outdoor temperature.
Comfort temperatures are defined using equation (1)
Tc = 0.534To + 12.9 (1)
where Tc is comfort temperature and To is average monthly mean outdoor temperature.
In equation (1) ‘ To ’, mean temperature of any month and is defined by
To = (T max+ T min ) / 2 (2)
In equation (2) Tmax and Tmin are the monthly average maximum and minimum temperatures which are
obtained from Table 1.
Standard that is frequently referred in evaluating comfort condition in Hot Humid Regions is ASHRAE
Std 55. A revised version of ASHRAE Std 55, known as Adaptive Comfort Standard (ACS), has been
produced to be applied for naturally ventilated buildings since the original version is found to be
irrelevant for naturally ventilated buildings. In the revised version, allowance for the warmer indoor
ISSN 2076-2895 (Print), ISSN 2076-2909 (Online) ©2012 International Energy & Environment Foundation. All rights reserved.
742 International Journal of Energy and Environment (IJEE), Volume 3, Issue 5, 2012, pp.739-748
temperature is given and to be applied during summer time for the naturally ventilated (NV) buildings. A
wider range of indoor temperature was given based on the findings from the occupants in the NV
buildings. The wider range is mostly influenced by the outdoor climate patterns which led to the
derivation of the optimum comfort temperature, Tcomf, that is based on the mean outdoor dry bulb
temperature, Ta,out:
Tcomf = 0.31Ta , out + 17.8 (3)
Tcomf, aiming to discover the temperature or combination of thermal variables (temperature, humidity
and air velocity) which most of the people consider ‘neutral’ or ‘comfortable’.
Ta,out is calculated according to equation (2).
Humphreys and Nicol [11] had also suggested that in evaluating thermal comfort using adaptive
principle, there are three main contextual variables that need to be considered which are the climate,
building and time.
Comfort temperatures according to equation (3) are tabulated in Table 2 for all the summer months in
Madurai –India.
Table 2. Comfort temperature for Madurai –India
Temp. June July Aug Sept Oct Nov Dec Jan Feb Mar Apr May
(˚C)
Maximum 37.9 37.7 37.0 36.6 35.9 30.8 29.8 31.3 33.5 37.2 38.7 38.2
(ambient)
Minimum 26.2 26.7 25.8 25.8 25.0 23.6 22.7 21.9 22.1 24.1 26.8 27.2
(ambient)
Mean 32.05 32.2 31.4 31.2 30.45 27.2 26.25 26.6 27.8 30.65 32.75 32.7
Comfort 27.74 27.78 27.53 27.47 27.24 26.23 25.94 26.05 26.42 27.30 27.95 27.94
3. Materials and experimental techniques
3.1 Materials
The sensible heat storage capacity of building materials has been recognized since ancient times. Heating
a liquid or a solid, without changing phase is called sensible heat storage. However, in order for sensible
heat storage to be effective in modern buildings, a number of problems arise such as high cost, excessive
mass and undesirable temperature fluctuations. Hence, there is a rationale for the development of latent
heat storage in building materials. Heating a material which undergoes a phase change (usually melting)
is called latent heat storage.
The characteristics of PCMs make them inherently suitable for use in buildings for energy conservation
purposes without the complications brought about by other thermal storage devices requiring separate
plant and space [12]. The improved thermal distribution, cost and space-saving implications are some of
the advantages of this type of thermal storage.
PCMS has high thermal conductivity so that the temperature gradient required for charging the storage
material is small. PCMS has high density, so that a smaller container volume holds the material. PCMS
has no chemical decomposition, so that the latent heat storage system life is assured. PCMS doesn’t
cause corrosiveness to construction material.
Within the human comfort temperature range (approximately 20–28ºC), latent heat storage materials
have been found to be very effective. Indeed, research has shown that PCM-impregnated building
materials can store 5-14 times more heat per unit volume than their conventional sensible storage
counterparts. Some Commercial PCMs have been also developed for building application. With respect
to thermal comfort criteria, the isothermal storage of heat energy is one of the most attractive features of
a PCM as a component building material [13].
Organic and inorganic compounds are the two most common groups of PCMs. Most organic PCMs are
non-corrosive and chemically stable, exhibit little or no sub cooling, are compatible with most building
materials and have a high latent heat per unit weight and low vapor pressure [14]. Their disadvantages
are low thermal conductivity, high changes in volume on phase change and flammability. Inorganic
compounds have a high latent heat per unit volume and high thermal conductivity and are Non-
ISSN 2076-2895 (Print), ISSN 2076-2909 (Online) ©2012 International Energy & Environment Foundation. All rights reserved.
International Journal of Energy and Environment (IJEE), Volume 3, Issue 5, 2012, pp.739-748 743
Flammable and low in cost in comparison to organic compounds. However, they are corrosive to most
metals and suffer from decomposition and sub cooling, which can affect their phase change properties.
So Organic PCMs are better for building applications [15].
Many potential PCMs were tested for building applications, including inorganic salt hydrates, organic
fatty acids and eutectic mixtures, fatty alcohols, neopentyl glycol, and paraffinic hydrocarbons. There
were several moderately successful attempts in the 1970s and 1980s to use different types of organic and
inorganic PCMs to reduce peak loads and heating and cooling energy consumption [16].
Recent research has shown that PCM-impregnated building materials show great promise as functional
and effective building elements which can affect significant energy savings. Hawes and Feldman [17]
have considered the means of PCM incorporation into the building by direct incorporation, immersion
and encapsulation.
Castellon et al. [18] studied how integrating PCM in construction materials (concrete in their case) would
affect the effective thermal energy storage (TES) of a building. Using the granules of microencapsulated
PCM as part of the aggregate for the concrete, the PCM is embedded simply and effectively within the
construction material. Their experiment included a building a small concrete cubicle with embedded
PCM and another cubicle made from regular concrete. The results indicate that the peak temperature of
the cubicle with PCM occurred about 2 hours later; this means that the cubicle was kept cooler longer.
The performance of PCM construction materials in terms of thermal comfort, an experimental and
numerical simulation study was fielded by Athientis et al. [19]. It was shown that the utilization of PCM
gypsum board in a passive solar building may reduce the maximum room resultant temperature by 4˚C
during the daytime and can reduce the heating load at night significantly. Peippo et al. [20] developed a
very useful procedure which may be used to select a PCM with predictable melting points adjustable to
the optimum temperature of the application.
Organic PCM -PEG E600 with Melting Point 25 & 31°c, specific heat 1800 J/kgk, Density 1.126 g/cm3
was selected as experimental material for study & analysis based on the weather data & the material
which is readily available in the market. Organic PCMs are Recyclable & reusable. Polyethylene Glycol
(PEG) E600 is chemically stable with high heat of fusion, safe and non reactive and recyclable.
3.2 Experimental techniques
Experimental building models each of one cubic feet were constructed using special type of hollow
bricks integrated with PCM Polyethylene glycol (PEG E600). Strength tests were performed for ordinary
bricks and the special type of hollow bricks in compression testing machine. Strength of ordinary brick
was 94 KN and the Strength of hollow brick was 84 KN. Difference in the compressive strength of
ordinary brick and the selected hollow brick for experimental model was negligible.
Building models each of 1 cubic feet using RCC slab, hollow bricks & cement mortar and tile roof,
hollow bricks & cement mortar were constructed to test the performance of PCM integrated walls with
different roofing systems. Glass test tube filled with phase change material PEG E600 was inserted
inside the hollow brick façade in two sides. Temperature sensor was used to measure the inside room
temperature & outside temperature on a Peak summer days June 15th 2011 to June 18th 2011. Building
model was painted with white emulsion since white reflects more radiation. For white Body, Reflectivity
(r) is equal to 1, Absorbtivity (α) is equal to 0 and Transmissivity (τ) is equal to 0.
3.2.1 Thermal performance analysis using PEG E600 integrated hollow brick walls covered by RCC
Slab placed in East West direction
Building model was constructed for 1 cubic feet using hollow bricks, plastered and painted white and
was covered with RCC Slab as in Figure 1. Glass test tube is filled with Polyethylene glycol E600 was
inserted inside the hollow bricks. Temperature was measured in on June 15th 2011 between 9.00 am to
3.30 pm. Building is kept toward East to West direction. From the temperature reading plotted it was
proved that until 12.30 pm the temperature at the inside of the building model was below the outdoor
ambient temperature. (Figure 2). It was efficient for 4.30 hr and there was an increase in indoor
temperature after 12.30 pm.
ISSN 2076-2895 (Print), ISSN 2076-2909 (Online) ©2012 International Energy & Environment Foundation. All rights reserved.
744 International Journal of Energy and Environment (IJEE), Volume 3, Issue 5, 2012, pp.739-748
Figure 1. Building model setup PEG E600 integrated hollow brick walls covered by RCC Slab
Figure 2. Thermal performance analysis graph using PEG E600 integrated hollow brick walls covered by
RCC slab placed in East West direction
3.2.2 Thermal performance analysis using PEG E600 integrated hollow brick walls covered by RCC
Slab placed in North South direction
Temperature was measured between 9.30 am to 4.30 pm on June 16th 2011(Figure3). Building when kept
towards North South direction, it was proved that indoor temperature of building model was below
outdoor ambient temperature until 2.00 pm. It was efficient for 6.00 hours.
3.2.3 Comparative result
Experimental model when placed in East to West was efficient for 4.30 hours. Oppositely when placed
towards North to South it was efficient for 6.00 hours. Comfort Temperature calculated within the
building model is 30.3˚C in E-W and 29.27˚C in N-S direction. Thermal analysis results shows that
indoor temperature of building model with RCC slab when placed in N-S direction is near to the range of
Thermal Comfort. Experimental research suggests that constructing building toward North to South
integrating PCM with conventional building materials is an efficient way for saving electrical energy in
Hot Humid Regions.
ISSN 2076-2895 (Print), ISSN 2076-2909 (Online) ©2012 International Energy & Environment Foundation. All rights reserved.
International Journal of Energy and Environment (IJEE), Volume 3, Issue 5, 2012, pp.739-748 745
Figure 3. Thermal performance analysis graph using PEG E600 integrated hollow brick walls covered by
RCC slab placed in North South direction
3.2.4 Thermal performance analysis using PEG E600 integrated hollow brick walls covered by Red Tile
Roof placed in East West direction and North South Direction
Building model was constructed for 1 cubic feet using hollow bricks, plastered and painted white and
was covered with Red Tile Roof as in Figure 4. Glass test tube is filled with Polyethylene glycol E600
was inserted inside the hollow bricks. Temperature was measured for 8 hours on June 17th 2011 and June
18th 2011 by place building model in East West and North South respectively.
Figure 4. Building model setup PEG E600 integrated hollow brick walls covered by red tile roof
3.2.5 Comparative result
It is efficient for 7 hours out of 8 hours during day time. Comfort Temperature calculated within the
building model is 29.4˚C in E-W and 29.6˚C in N-S direction. Thermal analysis results (Figures 5, 6)
shows that indoor temperature of building model with Clay tile roof when placed in both in N-S direction
as well as E-W direction is near to the range of Thermal Comfort.
ISSN 2076-2895 (Print), ISSN 2076-2909 (Online) ©2012 International Energy & Environment Foundation. All rights reserved.
746 International Journal of Energy and Environment (IJEE), Volume 3, Issue 5, 2012, pp.739-748
Figure 5. Thermal performance analysis graph using PEG E600 integrated hollow brick walls covered by
red tile roof placed in East West direction
Figure 6. Thermal performance analysis graph using PEG E600 integrated hollow brick walls covered by
red tile roof placed in North South direction
4. Results and discussion
Typical facades without the installation of PCM conduct solar radiation and dramatically heat up the
internal space. In contrast, building facades installed with PCM will gradually change its phase and store
heat throughout the day instead of conducting all heat into the internal space. As a result, PCM can
guarantee more stable internal temperatures, with no dramatic fluctuations, thus providing thermal
comfort to the dwellers. By installing PCM in the building facade, heat will be stored and only a small
amount of heat will be conducted to the internal space if the transition process is complete; when PCM
cannot store heat anymore [21].
From the building thermal performance analysis conducted in peak summer days of June2011in Madurai
Region it is observed that usage of PEG E600 is effective in reducing room temperature at comfortable
level during noon time. From the Building thermal performance analysis it is proved that constructing
building toward North –South Direction using PCM is best in this location. Maximum thermal
discomfort in building in hot humid Regions will be until 2.00 pm where as PEG E600 is effective until
3.00 pm in maintaining the room temperature to a comfortable level. Temperature analysis suggests that
ISSN 2076-2895 (Print), ISSN 2076-2909 (Online) ©2012 International Energy & Environment Foundation. All rights reserved.
International Journal of Energy and Environment (IJEE), Volume 3, Issue 5, 2012, pp.739-748 747
constructing building toward North to South using PCM is efficient way for saving electrical energy in
hot humid climates.
In building applications, only PCMs that have a phase transition close to human comfort temperature
(25–30ºC) can be used. Some Commercial PCMs have been also developed for building application. The
only way to maintain a pleasant temperature in summer without installing an air conditioning system is
to increase the thermal capacity of the structure. Apart from enhancing the comfort, a large reduction in
costs (Electrical Energy) can also be achieved by dissipating the accumulated energy during the night.
The development of an energy storage system may be one of the solutions to the problem when
electricity supply and demand is out of phase.
There two methods for incorporating phase change materials inside the building material currently in use
are impregnation of PCMs into porous materials and direct incorporation of PCMs into hollow brick
cavities.
PEG E600 for building application can be directly incorporated into Hollow Brick cavities and can be
used in building facade.
As a consequence of the PCM treatment, reduction on the peak temperatures between day-night was
observed and there is delay in the time to go to minimum or maximum temperatures. As a result of the
experimental observations, a reduction in energy consumption can be anticipated and an increase in
human comfort, due to a reduction of temperature variations during day and night.
5. Conclusion
The results show that the wall with incorporated with PCM can delay the temperature rise when the
environmental temperature increases. This study examines the new concept of incorporating PCM inside
the building material for enhancing the room air quality and reducing the energy consumption consumed
by the air conditionings in the buildings. It is the new way to design the smart buildings with light weight
by incorporating the PCMs inside the hollow cavity of brick.
Environment Friendly Cooling of building using phase change material inside the conventional building
material (brick) was studied. It is quite evident from the preceding reviews that the thermal
improvements in a building due to the inclusion of PCMs depend on the melting temperature of the
PCM, the type of PCM, the percentage of PCM used inside the conventional material, the climate, design
and orientation of construction of the building. When PCM -PEG E600 is applied inside the building
material (brick) the heat entering the room reduces considerably. The Efficiency of PEG E600 is 33.33%.
PCM offers the resistance for the heat flow and heat transfer was reduced. This research attempts to
select a suitable material for regions with hot humid Climatic condition.
References
[1] Zhang, D., Li Z., Zhou, J., Wu, K., “Development of thermal energy storage concrete”, Cement
and Concrete Research, 2004, (34), pp.927-934.
[2] Khudhair, A.M., Farid, M.M., “A review on energy conservation in buildings applications with
thermal storage by latent heat using phase change materials”, Energy Conversion and
Management, 2004, (45), pp.263-275.
[3] Hawes, D.W., Feldman, D., “Latent heat storage in building materials”. Energy and Buildings,
1993, (20), pp.77-86.
[4] Anderson, J., & Shires, D.. The Green Guide to Specification. Oxford: Blackwell Science. 2002
(3rd ed)
[5] Zhen Yang, Suresh V Garimella, “Isothermal storage of solar energy in building construction”,
Elsevier Ltd, Solar Energy 2010, vol. 35, (4), pp. 788-796
[6] Baetens R., Jelle B.P. and Gustavsen A. “Phase Change Materials for building applications: A
state- of- the- art review”. Energy and Buildings 2010, 42, pp.1361-1368.
[7] Manuel Ibanez, Ana Lazaro, Belen Zalba, Luisa F. Cabeza, “An approach to the simulation of
PCMs in building applications using TRNSYS” Applied Thermal Analysis, 2005, pp. 1796–1807.
[8] Givoni, B. Man, Climate and Architecture (Book). Amsterdam: Elsevier Publishing Company
Limited, 1969.
[9] I.A. Raja, J.F. Nicol, K.J. Mccartney, and M.A. Humphreys, "Thermal comfort: use of controls in
naturally ventilated buildings," Energy and Buildings, 2001, vol. 33, pp. 235-244.
[10] F.Nicol, “Adaptive thermal comfort standards in the hot-humid tropics”, Elsevier, Energy and
Buildings, 2004, vol. 36, (7), pp. 628-637
ISSN 2076-2895 (Print), ISSN 2076-2909 (Online) ©2012 International Energy & Environment Foundation. All rights reserved.
748 International Journal of Energy and Environment (IJEE), Volume 3, Issue 5, 2012, pp.739-748
[11] Humphreys, M.A., Nicol, J.F. “Outdoor temperature and indoor thermal comfort – raising the
precision of the relationships for the 1998 ASHRAE database of field”. ASHRAE Transactions
2000, 206 (2), pp. 485-492.
[12] K. Darkwa, P.W. O’Callaghan, “Simulation of phase change drywalls in a passive solar building”,
Elsevier, Applied Thermal Engineering, June 2006, vol. 26, (8-9), pp. 853-858
[13] Hai Jian Li, Zhi Jiang Ji, Zhi Jun Xin, Jing Wang. “Preparation of Phase change building
materials”, Advanced Material Research, 2010, Vol. 96, pp.161-164.
[14] Mohammed M. Farid, Amar M. Khudhair, Siddique Ali K. Razack, Said Al-Hallaj, “A review on
phase change energy storage: materials and applications”, Energy Conversion and Management,
2004, 45, pp.1597–1615.
[15] Feng Li, Yong Jun Hu, Ren Yuan Zhang, “The influence of Heating - Cooling Cycles on the
Thermal storage Performances of Al-17 Wt. % Si Alloy”, Advanced Materials Research, 2011,vol.
239 - 242, pp. 2248-2251.
[16] S.D. Sharma. “Latent heat storage materials and systems: A review” International Journal of Green
Energy, 2005, 2, pp.1–56,
[17] Hawes DW, Feldman D, “Absorption of phase change materials in concrete”, Solar Energy
Material and Solar Cells, 1992, vol. 27, pp.91–101.
[18] Castellon, C., Medrano, M., Roca, J., Nogues, M., Cabeza, L. F., & Castell, A. “Use of
Microencapsulated Phase Change Materials in Building Applications”. ASHRAE. project
ENE2005-08256-C02-01/ALT, 2007.
[19] Athientis A. K., Liu C., Hawes D., Banu D., Feldman D., Investigation of the thermal performance
of a passive solar test-room with wall latent heat storage, Building and Environment, 1997, 32, pp.
405-410.
[20] Peippo K., Kauranen P., Lund P. D., A Multicomponent PCM Wall Optimized for Passive Solar
Heating, Energy and Building, 1991, 17, pp. 259-270.
[21] M.Ravikumar, Dr. PSS. Srinivasan, “Phase change material as a thermal energy Storage material
for cooling of building”, Journal of Theoretical and Applied Information Technology, 2008, vol. 4,
pp. 503-511.
A. Madumathi is a Doctoral Research Scholar at Anna University, Tirunelveli, Tamilnadu, Inida and
Assistant Professor at the Department of Architecture, Thiagarajar college of Engineering, Madurai,
Tamilnadu, India. Her field of research is Thermal Performance Evaluation of residential buildings of
hot humid Regions of India. She is a Post-Graduate in Landscape Architecture from The School of
Architecture and Planning, Anna University, Chennai; her areas of interest are Landscape Design,
Sustainable Design, Climatology and Energy Efficient Architecture.
E-mail address: madhu@tce.edu
M.C. Sundarraja has finished his Doctoral Degree in Civil engineering in Anna University, Chennai,
and Post Doctoral Fellowship from Queensland University of Technology, Australia in 2008. He is
working as Assistant Professor at the Department of Civil engineering, Thiagarajar college of
Engineering, Madurai, Tamilnadu, India. His field of research is strengthening of RCC structures. His
areas of interest are strengthening of RCC structures, climate Responsive Architecture, vernacular
Architecture etc. He has presented various international journals in the field of climate responsive
architecture. He is a Recipient of Endeavour Research Award, Australian Government,31 March 2009,
His sponsored research projects includes SERC-DST Fast Track Project for Young Scientist,DST, New
Delhi, UGC-Major Research Project, UGC, New Delhi.
E-mail address: mscciv@tce.edu
ISSN 2076-2895 (Print), ISSN 2076-2909 (Online) ©2012 International Energy & Environment Foundation. All rights reserved.
View publication stats