(Edition June 2004)
HP12-50W                      12V 9Ah
                                                                                                    General Features
 VISION Rechargeable Products
    Sealed Lead Acid Battery
        www.vision-batt.com                      Positive and negative plates in lead-calcium tin alloy             Very high power output
                                                 Superior energy density                                            Application specific designs
                                                 Operates at a low internal pressure.                               A couple Range from 13W to 890W per cell for 10' @ 1.60Vpc
                                                 Gas Recombination                                                  Six months shelf life at 20o C
                                                 Usable in any orientation                                          Design life 5 years
                                                 A recognized component of UL
                                                                                                                                 Dimensions and Weight
HP&HF Series                                                                                                                                SI Units               English Units
                                                                                                                Length                        151mm                    5.94inch
High Rate Discharge
                                                                                                                Width                         65mm                     2.56inch
The new VISION HP/HF series batteries are
specially designed for applications where                                                                       Height                        94mm                     3.70inch
need high power output. By optimum design
                                                                                                                Total Height                  100mm                    3.94inch
of battery grids and plate paste formula, the
HP/HF series can deliver up to 40% more                                                                         Approx. Weight                2.80Kg                   6.17lbs
power than VISION standard CP/FM series.
                                                                                           Performance Characteristics
Shenzhen Center power tech co., ltd has
more than 15 year's experience in the
                                                 Nominal Voltage 12V                                                     Operating Temperature Range
manufacturing of VRLA batteries.
                                                 Number of cell 6                                                               Discharge -20~60o C
SZCPT is one of the biggest manufacturers of
                                                 Nominal Capacity 68 o F(20 o C)                                                Charge -10~60o C
SLA (or VRLA) batteries in the world, the
                                                       10 min wattage @1.6V 50W/cell                                            Storage -20~60o C
biggest one in Mainland China and the first in
                                                 Nominal Capacity 77 o F(25 o C)                                         Max. Discharge Current 68o F(20 o C) 135A(5s)
China to develop and commercialize the
                                                       20 hour rate (0.45A, 10.5V) 9.00Ah                                Short Circuit Current 670A
sealed lead-acid battery with brand name
                                                                                                                         Charge Methods: Constant Voltage Charge 68o F(20 o C)
VISION and has been at the forefront of
                                                 Internal Resistance                                                            Cycle use 14.5-14.9V
battery technology from day one.
                                                        Fully Charged battery 68o F(20 o C) 18mOhms                             Maximum charging current 3.6A
                                                 Self-Discharge                                                                 Temperature compensation -30mV/o C
SZCPT leads the world in innovative battery
                                                        3% of capacity declined per month at 20o C(average)              Standby use 13.6-13.8V
technology. Our global network of sales and
                                                                                                                                Temperature compensation -20mV/o C
service engineers, backed in turn by our
agents and distributors, means that we are
currently active in more than 100 countries.
                                                                                             Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China
Shenzhen Center Power Tech. Co., Ltd                                                         Tel: 86 755 8431 8088 Fax: 86 755 8431 8038 E-mail: sales@vision-batt.com
                                                                                             Website: http://www.vision-batt.com
                                VISION Rechargeable Products
                                Sealed Lead Acid Battery
    www.vision-batt.com                                                                                                                                                                                                                                (Edition June 2004)
                                                                                                              HP12-50W                        12V 9Ah
  Discharge Data
                                                                                                   Constant Current Discharge Data ( Amperes at 20oC )
   End Voltage
                  5min 10min 15min 20min 25min 30min 35min 40min 45min 50min 55min                                                   1h     1.5h      2h           2.5h              3h          4h       5h            6h      7h       8h     9h     10h    12h    24h
   Per cell / V
      1.60        43.8   29.3     21.6   16.8        13.9                 12.0        10.6    9.56          8.76    7.98      7.35   6.82   4.79     3.77        3.16                2.75        2.11    1.73         1.45     1.25      1.11   0.99   0.90   0.77   0.42
      1.65        41.2   27.7     20.4   15.9        13.2                 11.3        10.1    9.09          8.33    7.60      7.00   6.50   4.57     3.60        3.02                2.63        2.02    1.66         1.39     1.20      1.06   0.95   0.86   0.75   0.41
      1.70        38.6   26.1     19.3   15.0        12.5                 10.7        9.52    8.61          7.91    7.22      6.66   6.19   4.35     3.44        2.88                2.52        1.94    1.59         1.34     1.15      1.02   0.91   0.83   0.72   0.39
      1.75        36.0   24.5     18.2   14.2        11.7                 10.1        8.99    8.14          7.48    6.84      6.31   5.88   4.14     3.27        2.75                2.40        1.85    1.52         1.28     1.11      0.98   0.88   0.80   0.69   0.38
      1.80        34.5   23.6     17.6   13.7        11.4                 9.85        8.76    7.94          7.30    6.68      6.17   5.75   4.05     3.20        2.69                2.35        1.81    1.49         1.26     1.09      0.96   0.86   0.78   0.68   0.37
                                                                                              Constant Power Discharge Data ( Watts per cell at 20oC )
   End Voltage
                  5min 10min 15min 20min 25min 30min 35min 40min 45min 50min 55min                                                   1h     1.5h      2h           2.5h              3h          4h       5h            6h      7h       8h     9h     10h    12h    24h
   Per cell / V
      1.60        75.3   50.0     37.0   29.2           24.6              21.5        18.9    16.9          15.4    14.2      13.2   12.3   8.51     6.62         5.48               4.72        3.71    3.10          2.66    2.34      2.10   1.92   1.77   1.52   0.84
      1.65        72.1   48.1     35.7   28.2           23.8              20.8        18.3    16.4          15.0    13.8      12.8   12.0   8.28     6.44         5.34               4.60        3.62    3.03          2.60    2.29      2.06   1.88   1.74   1.50   0.83
      1.70        68.9   46.3     34.4   27.3           23.0              20.1        17.7    15.9          14.5    13.3      12.4   11.6   8.04     6.26         5.20               4.49        3.53    2.96          2.54    2.24      2.02   1.84   1.70   1.47   0.82
      1.75        65.7   44.4     33.1   26.3           22.1              19.4        17.1    15.4          14.1    12.9      12.0   11.3   7.81     6.09         5.06               4.37        3.44    2.89          2.48    2.19      1.97   1.80   1.67   1.45   0.80
      1.80        62.5   42.5     31.8   25.3           21.3              18.7        16.5    14.9          13.6    12.5      11.6   10.9   7.58     5.91         4.92               4.25        3.36    2.82          2.42    2.14      1.93   1.76   1.63   1.42   0.79
  Performance                                                               Constant Current Discharge                                                                                  Constant Power Discharge
                                                                100                                                                                                        100
  Drawings
                                                                10                                                                                                         10
                                                                                                                                                            Wat t age/ W
                                                Cur r ent / A
                                                                 1                                                                                                          1
                                                                      1          10          100           1000     10000                                                        1          10          100           1000     10000
                                                                 0                                                                                                          0
                                                                  1.60V           1.65V            1.70V                                                                    1.60V           1.65V             1.70V
                                                                  1.75V           1.80V                            Time/min                                                 1.75V           1.80V                             Time/min
                                                                                                                                                   Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China
Shenzhen Center Power Tech. Co., Ltd                                                                                                               Tel: 86 755 8431 8088 Fax: 86 755 8431 8038 E-mail: sales@vision-batt.com
                                                                                                                                                   Website: http://www.vision-batt.com