El Access Doors v7.7
El Access Doors v7.7
ZENNIHOME
A. SEE SHEET E-001 FOR GENERAL NOTES
D. ROUTE ALL WIRES IN WALLS, FLOORS, AND CEILINGS BEHIND FINISHED SURFACES;
WIRES SHALL BE ROUTED TO TAKE THE MOST DIRECT PATH POSSIBLE BACK TO THE
WP
SP#2 PRIMARY LOAD CENTERS
D2 E. ALL INTERIOR RECEPTACLES ON PANELS SHALL BE AFCI RATED IF NOT MARKED OTHER
F. ALL RECEPTACLES MARKED AS GFCI SHALL BE GFCI RATED OR FED FROM A GFCI
SP#1 SP#3 SP#3 SP#5
CIRCUIT BREAKER
SP#1
USB C
USB C
SP#3
SP#1
USB C
KEY NOTES
BEDROOM
SP#3 SP#5
02
1 CONDUIT FOR ELECTRICAL SERVICE MAIN (ESM). ESM TO BE INSTALLED BELOW GRADE
ON-SITE AFTER UNIT HAS BEEN PLACED; SERVICE MAIN SHALL COMPLY WITH LOCAL PROJECT
LIVING UTILITY REQUIREMENTS AND NEC. UNDERGROUND SHALL BE PVC SCHEDULE 40.
MASTER
BEDROOM
ROOM 2 METER AND MAIN SWITCH ARE RATED, 150A, 3W, 240V, NEMA 3R, MAIN IS RATED
120/240V SERVICE WITH 150A MCB.
1280 V4.1A IRC
D1 3 PROVIDE ENGRAVED NAMEPLATES ON ALL SWITCHES ON BUILDING EXTERIOR PER
NEC.
4 60A, 2P, NEMA 3R NON-FUSED SWITCH PER NAME PLATE, DISCONNECT FOR CU-1 PER
C2 EQUIPMENT NAME PLATE. ARIZONA
JB-C4 J J
JB-C3 JB-C2 J J
JB-C1 5 EXTERIOR RECEPTACLES SHOULD BE WEATHERPROOF AND GFCI PROTECTED.
SP#1 SP#3 SP#2, SP#3 SP#5, SP#26
6 DRYER OUTLET, 30A, 3P, 4W, 250V,+48"AFF, STACKED WASHER/DRYER.
SP#1 SP#5 7 ADJUST HEIGHT AS REQUIRED BY EQUIPMENT (TYP).
8 J-BOX FOR ELECTRICAL CONNECTION OF AC INDOOR UNIT
11 SP#3
11
9 SWITCHED RECEPTACLE FOR GARBAGE DISPOSAL. PROVIDE SWITCH ABOVE COUNTER Date 06.11.2025
SP#5 TO SWITCH DISPOSAL VIA RECEPTACLE
USB C
SP#1
10
11
12x12x6 WALL J-BOX FOR FUTURE CONNECTION WITH SOLAR SYSTEMS
J-BOXES FOR LIGHTING AND RECEPTACLE CIRCUITS CONNECTION BETWEEN MODULES
Project No.:
SP#3 (INSTALLED IN THE CEILING, ACCESS IS ORGANIZED THROUGH THE ACCESS PANEL)
12 J-BOX FOR CONNECTING ELECTRICAL PANELS (INSTALLED IN THE CEILING, ACCESS IS Rev.0 100% CD SET 06.11.2025
ORGANIZED THROUGH THE ACCESS PANEL)
E-103 5 SUB PANEL 13 J-BOX FOR ELECTRICAL CONNECTION OF WATER HEATER
AFF: 53 5/8"
MP#26
USB C
NOTES:
C1
0' - 8"
0' - 8"
B2 NOTED.
JB-B5
J
JB-B2 J J
JB-B1 2. HOUSE DATUM: X.X'= 100'-0"
SP#31, SP#21 MP#1,3 MP#26 3' - 9 1/2"
11 7 SHALLOW
MP#21 MP#22 MP#26 11 12
8 PANTRY STUD
J
B1
0' - 8"
0' - 8"
MP#26 MP#26
A2 MP#24 MP#19
GFCI JB-A1 J J
JB-A2 GFCI
MP#14,16, MP#21 MP#10,12
WD
6
J
10
2 2 E-103
SECONDARY
1 1
MASTER BATHROOM SERVICE PANEL
GFCI
KITCHEN
BATHROOM
MP#9
AFF: 37"
MP#19 EF-1
7
GFCI
13
J
MP#11
MP#18, 20 MP#9 RH 9
AFF: 48" AFF: 37" HALLWAY MP PANEL
GFCI ER GFCI GD GFCI GFCI AFF: 53 5/8"
MP#17
GFCI
MP#7 MP#13 MP#7 MP#7 MP#19 GFCI
MP#24 MP#9 AFF: 37" MP#2,4 AFF: 37" AFF: 22" AFF: 37" AFF: 37" AFF: 42"
AFF: 4 1/2"
A1
MP#15
WP
POWER PLAN
5
Scale: As indicated
POWER PLAN
1
1/2" = 1'-0"
E-102
Drawn by: Author