spc1 en
spc1 en
Features Sensors
● Various function
Sensors
(G)
Please read “Safety considerations” in operation Connectors/
manual before using. Connector Cables/
Sensor Distribution
Boxes/Sockets
SPC 1 - 35 - E
Controllers
Specifications (L)
Model SPC1-35-E SPC1-50-E Panel
Meters
Power supply 220VACᜠ 50/60Hz
(M)
Allowable voltage range 90 to 110% of rated voltage Tacho /
Speed / Pulse
Operating frequency fluctuation ±1Hz Meters
Min. 100
94.6 2-M4 TAP
37.2
108
Min. 100
124.8
Min. 100
Min. 30
Connections
1. External connection
1 2 3 4 5
R T W U
F.G. +5V IN IN 0V
Rapid fuse
(external
attachment)
SOURCE LOAD
220VAC (resistive load only)
50/60Hz
2. Connection of control input terminals
1) DC4-20mA control input
It controls 0 to 100% when you apply DC4-20mA on ④, ⑤ terminals when power is applied.
Sensor or other
controlling equipment 1-5VDC
(+) (-)
1 2 3 4 5
F.G. +5V IN IN GND ※This function must not be used in ON/OFF control method.
External contact
or switch
1 2 3 4 5 ※It is available for all control methods.
F.G. +5V IN IN GND OUT ADJ and SOFT START functions are not available
in ON/OFF control method.
I-30
Single-Phase, Power Controller
4) External adjuster control input (A)
After power is applied, connecting the external adjuster 1㏀ to ②, ③ and ⑤ terminals and turning adjuster control from 0% Photoelectric
Sensors
to 100%.
It is available to control as OUT ADJ, adjuster for the above 1), 2), 3) and set at 100% when it is not used. (B)
Fiber
Optic
(max.) ③ ① (min.) Sensors
24VDC
(F)
+ - Rotary
Encoders
(H)
※Tighten the terminal screw with the below tightening torque. ※Use terminals of size specified below. Temperature
Controllers
Unit Description 12
(K)
Timers
(L)
Panel
10 Meters
1. Case
11 2. Terminal block cover
(M)
Tacho /
1 Speed / Pulse
3. Terminal block for control input Meters
(S)
Field
Network
4 5 Devices
12
Factory Default
(T)
Software
I-31
SPC1 Series
Operation and Function
Front
1. SOFT START setting adjuster (0 to 50 sec)
2. Output limit setting adjuster (0 to 100%)
3. Output indicator
4 4. Control method selection switch
PHASE: Phase control method
CYCLE: Cycle control method
ON/OFF: ON/OFF control method
1 2 3
※When selecting cycle control method, the cycle has been set as 0.5 sec. It can be changed to 2 sec, 10 sec by selection.
※The contorl method setting cannot be changed wwhile it is operating. Turn OFF the power at first then change the
setting and supply the power again.
1) Phase control
It is output type to control phase of an alternating signal according to control input signal.
● Equal division type of phase according as control input ● Equal division type of power according as control input
This is analog type to output control angle with dividing It divides control angle non-equally according as control
equally according as control input signal. It shows power input signal then make power curve linearization, so it
characteristic as (Fig. 1) and it might occur over power and becomes possible to output the power, which is proportioned
lack power at point middle of control input. control input as outputting (Fig. 1).
(Fig. 1) (Fig. 2)
100% 100%
0% 100% 0% 100%
1VDC Control input 5VDC 1VDC Control input 5VDC
DC4mA DC20mA DC4mA DC20mA
※To change the control mode, change TP3 of PCB as below.
※ SHORT OPEN
I-32
Single-Phase, Power Controller
When control input signal is 0% (DC4mA, 1VDC) When control input signal is 25% (DC8mA, 2VDC) (A)
Photoelectric
Sensors
(B)
Fiber
Optic
T: Cycle (0.5sec) T: Cycle (0.5sec) Sensors
(C)
When control input signal is 50% (DC12mA, 3VDC) When control input signal is 100% (DC20mA, 5VDC) Door/Area
Sensors
(D)
Proximity
Sensors
(F)
JP1 JP2 Cycle (sec) Rotary
Encoders
SHORT SHORT 0.5sec
(G)
SHORT OPEN 2.0sec ※ SHORT OPEN
Connectors/
Connector Cables/
Sensor Distribution
OPEN SHORT 10sec Boxes/Sockets
(I)
SSRs / Power
Output Controllers
3) ON/OFF control-Zero cross
This function is when control input is ON, output is 100%.
(J)
When it is OFF, output is 0%. Counters
It is the same function as SSR (Solid State Relay).
(It always turns ON/OFF at zero point of AC.)
Control ON 100% (K)
※OUT ADJ. and SOFT START function are not Timers
input
available in ON/OFF control method. OFF 0%
< Output wave form of ON/OFF control > (L)
Panel
OUT ADJ. (output limit) (0 to 100%) Meters
This function will be [Control input (%) × OUT ADJ. (%) = Output (M)
Output] and it controls the power supplied into the load. 100% Tacho /
Speed / Pulse
Although control input is 100% (5V or 20mA), the output is Meters
When OUT ADJ
the 50% which is proportioned with OUT ADJ. When not 75% is 100% (N)
using OUT ADJ. function, please make set value 100%. Display
Units
※This function must not be used in ON/OFF control 50%
method. When OUT ADJ (O)
25% is 50% Sensor
Controllers
SOFT START (0 to 50 sec) Control input (P)
This function protects the load in cases that the set 0% 50% 100% Switching
Mode Power
temperature is high, such as controlling the load (platinum. <The output characteristic of OUT ADJ. and control input> Supplies
molybdenum, tungsten, infrared lamp, etc.) in which inrush (Q)
current flows when power is supplied, or showing large Output Stepper Motors
The output which & Drivers
width of temperature rise during initial operation. is applied into the
& Controllers
100%
SOFT START set time (T) is the required time that output load is 100% (R)
reaches to 100%, and it is differentiated by OUT ADJ. Graphic/
Logic
set value. For example, SOFT START is set as 10sec The output which Panels
and OUT ADJ. is set as 70%, it takes 7 sec to reach goal 50% is applied into the (S)
load is 50% Field
output. Network
Devices
[Set time (T)×OUT ADJ. set value (%)=10 sec×0.7=7 sec]
If increasing the OUT ADJ. before output reaches to 0 Time (T)
goal output, it delays as much as the value, multiply of T/2 Software
increased value (%) and SOFT START set time. When not T T: SOFT START setting time
using SOFT START function, please make set value 0.
※This function must not be used in ON/OFF control ※T: Time to get the output which is applied into the load is
method. 100%.
T/2: Time to get the output which is applied into the load
is 50%.
OUT display
This is LED lamp to display the status of output and will be getting brighter according as output.
(0%: min. LED light, 100%: max. LED light)
I-33
SPC1 Series
Applications
E.g. 1) When controlling by limiting the power at ON/OFF E.g. 2) This is how to control 0 to 100% without
in phase control and cycle control method. external adjuster in phase control and cycle
For example, if it needs to control 80% output when control method.
it is ON, 24% output when it is OFF, please keep
below. It is possible to control 0 to 100% by turning
OUT ADJ. in state of connecting terminal 2
Firstly set OUT ADJ. as 80% and connect external and terminal 3.
adjuster and external relay contact switch as the
<Control input terminal connection>
figure then set external adjuster as 30%.
● When the External contact signal is ON F.G. +5V IN IN GND
: 100% (contact input)×80% (OUT ADJ.)=80% 1 2 3 4 5
● When the External contact signal is OFF
: 30% (adjuster input)×80% (OUT ADJ.)=24%
<Control input terminal connection>
F.G. +5V IN IN GND
1 2 3 4 5
External
adjuster 1kΩ
40 40
30 30
20 20
10 10
0 0
0 10 20 30 40 50 0 10 20 30 40 50
Ambient temperature [℃] Ambient temperature [℃]
Remove of Case
After disconnecting all power sources supplied to the product,
remove the case.
Push the Joint part (4 points) on the right and left side of the case
with the flat head screwdriver, and disassemble the case.
When using the tool, be careful not to injure yourself.
Proper Usage
Cautions during use
1. Follow instructions in 'Cautions during Use'. Otherwise, it may cause unexpected accidents.
2. Use the product, after 3 sec of supplying power.
3. Before use, set the mode and function according to the specification.
Especially, be cautious that the product does not operate when OUT ADJ. is set to 0%.
Since mode/parameter can not be changed during operation, set the mode and function after turning off the power.
4. To ensure the reliability of the product, install the product on the panel or metal surface vertically to the ground.
5. Install the unit in the well ventilated place.
6. While supplying power to the load or right after turning off the power of the load, do not touch the body and heat sink.
Failure to follow this instruction may result in a burn due to the high temperature.
7. Install a power switch or circuit breaker in the easily accessible place for supplying or disconnecting the power.
8. Do not wire to terminals which are not used.
9. The rapid fuse must be connected between R terminal and the power source.
10. D o not use near the equipment which generates strong magnetic force or high frequency noise.
11. This unit may be used in the following environments.
①Indoors (in the environment condition rated in 'Specifications')
②Altitude max. 2,000m
③Pollution degree 2
④Installation category III
I-34