Legrand Cataloge All UPS
Legrand Cataloge All UPS
UNINTERRUPTIBLE
POWER SUPPLY
up to 21 MVA
GENERAL
CATALOGUE 2023
GLOBAL SPECIALIST IN ELECTRICAL
AND DIGITAL BUILDING INFRASTRUCTURES
UPS systems: UPS units up to
Consumer and Soho
SINGLE-PHASE UPS
Keor Multiplug Keor SP Keor PDU Keor SPE Tower
Modular
Trimod HE Trimod MCS Keor MOD
THREE-PHASE UPS
Conventional
Keor Compact Keor T Evo Keor HP
Software
Universal battery
cabinets for all
three-phase UPS
from 10 to 800 kVA.
P. 62 P. 64
2
21 MVA
Modular Conventional
Keor SPE RT Megaline Keor LP Daker DK Plus Keor S
Single-phase UPS Single-phase UPS, on-line Single-phase UPS, on-line Single-phase UPS, on-line Single-phase UPS, on-line
line interactive VI-SS double conversion VFI double conversion VFI-SS-111 double conversion VFI double conversion VFI
from 750 to 3000 VA from 1250 to 10000 VA from 1000 to 3000 VA from 1000 to 10000 VA from 3000 to 10000 VA
P. 18 P. 20 P. 24 P. 26 P. 30
UPSaver
Keor HPE Keor XPE UPSaver
and software
Network interfaces
and accessories
P. 65
UPS CATALOGUE 3
UPS
High performance, uninterruptible service
and energy efficiency.
The wide diffusion of UPS systems generally stems from an increasing dependence on electricity
and the need to protect a range of equipment, data and processes that are crucial to companies.
Power electronics is focused on the design and development of static UPS with increasing
performance, which provide adequate energy saving along with lower environmental impact.
Energy efficiency
Thanks to the use of the latest technologies, the new concept UPS boast high efficiency
and an intelligent battery charging system that extends its useful life.
In addition to significantly reducing UPS consumptions and operating costs, these
features contribute to reducing the environmental impact of battery disposal.
4
LEGRAND IS A WORLD LEADER
IN THE MANUFACTURING
OF ELECTRICAL EQUIPMENT,
and offers a wide range of solutions for the tertiary
sector, that meet all system demands, from
cabling systems for data networks, to channelling
and distribution systems, to plant control and
management.
Today, with a view to technological development
that respects the environment and in order to face a
constantly evolving market, Legrand proposes a new
UPS range, a complementary offer of technological
functions able to guarantee maximum protection for
all systems.
UPS CATALOGUE 5
SUSTAINABILITY
Corporate Social Responsibility
Green management and sustainable supply chain: these concepts are part of Legrand’s
Corporate Social Responsibility, which is the company’s commitment to drawing up a strategy and
implementing it with practical actions aimed at socially responsible behaviour towards everything
around it, such as people, things and environment.
CSR involves the management of human resources, the organization and division of labour and the
management of natural resources. CSR aims to assess the impact that the company’s actions and
decisions have internally, but also externally, on the stakeholders and the environment.
Circular economy
We are committed to creating a system that involves all stakeholders to share values, objectives and
actions in order to control and reduce the environmental impact of all our economic and production
processes, reduce waste and environmental impact and transform what would once have been defined as
«waste» into new resources.
Controlling these aspects has an impact on the entire life cycle of the product, starting from the design
of new concepts and new specifications for the materials the UPS is made of; this is possible through
responsible design and procurement processes (so-called «green procurement»), with a strong focus on
research and the use of innovative materials from the circular economy and alternative raw materials.
When a product ends its life, all these materials can become high value-added resources that can be used
in other production cycles.
Digitalization
New information technologies allow us to reduce the use of several paper
documents in favor of the digital format: in this way the information is
always and everywhere accessible from a PC or smartphone and at the
same time we can avoid the felling of many trees.
Digitization also becomes an important driver of the circular
economy, since it allows the use of tools for performance data
analysis and preventive diagnostics, both useful for optimizing
the life cycle and durability of the product.
6
PEOPLE
BUSINESS ECOSYSTEM
or how Legrand interacts ethically with the whole ecosystem
of its activities.
BUSINESS
PEOPLE ECOSYSTEM
or how Legrand engages with all of its employees
and stakeholders.
ENVIRONMENT
ENVIRONMENT
or how Legrand intends to limit the Group’s
environmental impact.
Efficiency
Our R&D team is constantly working on the
development of increasingly efficient UPSs that
allow high and incremental performance with
minimum energy dissipation; with regard to CO2
emissions, we are implementing processes and
products that represent an improvement in the
percentage of carbon footprint compared to the
past. But efficiency is not only synonymous
with high performance. For us, efficiency also
means ecodesign: this implies that the UPS is
designed to be easily repaired, maintained and
it’s easy to separate its components.
This means increasing the durability
of our UPSs and the possibility of reusing
and recycling them at the end of their life.
EPD/PEP
For each product range we draw up an EPD (Environmental Product
Declaration) or PEP (Profil Environnemental Produit) in line with ISO 14025:
it is a declaration that is a sort of environmental photograph of the product.
The EPD is drawn up according to the concept of Life Cycle Assessment:
it examines the environmental impact of a product throughout its life cycle,
from the development of product specifications to the choice of materials
to be used and the end-of-life destination of the product itself.
UPS CATALOGUE 7
LEGRAND UPS
Distinguishing characteristics
High performance Environmentally sustainable products
The innovative design and high quality of the components Efficient UPS built with maximum attention to detail.
used enable our UPS to achieve up to 97.2% efficiency, Moreover, Legrand has developed an innovative testing
leading to significant energy savings. system which reduces the energy consumed for each
device manufactured.
Reliable electronics
The optimum sizing of the power stages and thorough
testing of each unit ensure excellent reliability.
Services
Legrand provides a complete range of services to meet the
demands of all its customers
8
Range of application
Each type of UPS is characterised by different
design properties, which means that the
range is ideally suitable and usable in different
environments, from domestic to tertiary
and industrial sectors, and applications
in specific fields.
DOMESTIC APPLICATIONS
Video surveillance, home alarms, smart TV,
Home Entertainment systems
TRANSPORT
Airports, rail and ship transport
UPS CATALOGUE 9
RANGE
LEGRAND offers a range of UPS products that are divided into 2 different types of products:
Online
SINGLE-PHASE UPS
Trimod HE Trimod MCS Keor MOD Keor Compact Keor T Evo Keor HP
Modular
THREE-PHASE UPS
10
Keor Multiplug Keor SP Keor SPE Tower Keor SPE RT Keor PDU
Conventional UPSaver
UPS CATALOGUE 11
SINGLE-PHASE UPS
The Legrand single-phase UPS range Consumer and Line Interactive
is comprehensive and complete, with
solutions that meet the demands of
These are compact UPS, easy to install and configure
different application sectors, from
and provide an excellent high quality/price ratio
domestic to tertiary. together with the guarantee of a long-term investment.
They are equipped with LED indicators that provide
The range is available from 600 VA up monitoring of the UPS status, whilst guaranteeing
to 10000 VA and is divided into 2 types protection of the devices connected to the same.
of products: The Line Interactive products are equipped with
a filtering and stabilizing circuit (AVR: Automatic
- Consumer and Line interactive Voltage Regulator).
This version comprises:
- On-Line double conversion
Keor Multiplug - Keor SP - Keor SPE Tower -
Keor SPE RT - Keor PDU.
Keor LP
These UPS use high frequency PWM technology, suitable UPS for low and medium power applications,
for use in professional environments available with different types of output sockets.
such as IT application, offices, factories, All versions have a slot for connecting SNMP
shops and points of sale. communication interfaces.
They are fitted with: THE ON-LINE RANGE
• DSP microprocessors for precise, constant control
of all measurements and of the power factor
correction circuit (PFC)
• Transformer-free technology electronics for high
quality energy output with up to 96% efficiency.
• Hermetically-sealed, maintenance-free,
valve regulated rechargeable batteries,
lodged inside a designated section of the UPS
or in one or more external cabinets.
The products that are part of this version are:
Keor LP- Daker DK Plus - Keor S - Megaline. Keor LP
from 1000 to 3000 VA
12
Keor Multiplug - Keor SP - Keor SPE Tower - Keor SPE RT Keor PDU
These are line-interactive technology UPS that guarantee total and reliable protection for all It is specifically designed
Small-Office and Home-Office applications. They are supplied with electronic voltage regulator for installation in 19”
and telephone protection. panels and racks.
IT is equipped with devices
THE CONSUMER AND LINE INTERACTIVE RANGE to protect against full battery
discharge, overloads
and short circuits.
Keor Multiplug Keor SP Keor SPE Tower Keor SPE RT Keor PDU
from 600 to 800 VA from 600 to 2000 VA from 750 to 3000 VA from 750 to 3000 VA 800 VA
n Characteristics
3 100 81 3 100 82
General Characteristics 3 100 83 3 100 84
Nominal power (VA) 600 800
Active power (W) 360 480
Technology Line interactive VI
Waveform Simulated Sinewave
Input
14
Keor SP
Single-phase VI
n Characteristics
3 101 80 3 101 83 3 101 86 3 101 89 3 101 92
General 3 101 81 3 101 84 3 101 87 3 101 90 3 101 93
Characteristics 3 101 82 3 101 85 3 101 88 3 101 91 3 101 94
Nominal power (VA) 600 800 1000 1500 2000
Active power (W) 360 480 600 900 1200
Technology Line Interactive VI
Waveform Simulated Sinewave
3 101 83 3 101 92
Input
Input voltage 230 V ± 10%
Characteristics: Input frequency 50-60 Hz +/- 5Hz
- 3-colour LED bar
- Mute Button (Silent) Input voltage range 170 V-290 V
- Internal AVR (automatic voltage regulator) Output
- USB Port
- Output sockets available for IEC, French or German standards Output voltage 230 V ± 10%
Output frequency 50/60 Hz +/-1Hz
(nominal)
Item UPS with IEC output sockets
USB Charger - USB type A (female)
Nominal Active Back-up time No. of sockets Communication
power power (min) IEC ports Communication and Management
(VA) (W)
Screen and signalling 2 buttons and LED bar to monitor UPS status
3 101 80 600 360 up to 15 4 USB HID in real-time
3 101 83 800 480 up to 15 4 USB HID Remote control available
3 101 86 1000 600 up to 10 6 USB HID +RS232 Mechanical Characteristics
3 101 89 1500 900 up to 10 6 USB HID +RS232 Dimensions HxWxD (mm) 120 x 138 x 330 148 x 173 x 380
3 101 92 2000 1200 up to 10 6 USB HID +RS232 Net weight (kg) 5 5.5 9 10.5 11.8
Ambient Conditions
UPS with IEC output socket + German standard Operating temp. (°C) 0 – 40
Nominal Active Back-up time No. of sockets Communication
power power (min) IEC+German ports Relative humidity (%) < 95% non condensing
(VA) (W) standard
Noise at 1 m (dBA) < 40
3 101 81 600 360 up to 15 1+1 USB HID Estimated content
3 101 84 800 up to 15 1+1 USB HID of circular economy 27%
480 derived materials
3 101 87 1000 600 up to 10 2+2 USB HID +RS232
Recyclability rate
3 101 90 1500 900 up to 10 2+2 USB HID +RS232 calculated using the
3 101 93 2000 1200 up to 10 2+2 USB HID +RS232 method described in 43%
technical report
UPS with IEC+ French socket IEC/TR 62635*
Nominal Active Back-up time No. of Communication
Conformity
power power (min) sockets ports Certifications EN 62040-1, EN 62040-2, EN 62040-3
(VA) (W) IEC+FR
Accessories
3 110 78 10A British Standard cable for all Keor SP
NOTE: the stated backup times in minutes are estimated and may vary according to the
load characteristics, operating conditions and environment.
French socket
n Characteristics
General Characteristics
Nominal power (VA) 800
Active power (W) 480
3 103 32 Input
Input voltage 230 V
Input frequency 45-65 Hz
Input voltage range 180 - 270 VAC
Output
Output voltage 220/230/240 Va.c. ±10%
Nominal output frequency 50/60 Hz ±1%
3 110 18 Power factor 0.6
Battery
Type VRLA - AGM without maintenance
Characteristics: Charge time (h) 4-6 (90% capacity)
- Low energy consumption
- Economically advantageous solution Communication and Management
- More sockets with complete protection Remote control Available
- Front installation and maintenance
- Silent operations Screen and signalling 3 LEDs to monitor UPS status in real-time
- Less space occupied inside the cabinet Protection
- Lower installation weight
- Ease of wiring and installation Protection against battery
Protection type dying, overload and short circuit
Mechanical Characteristics
Item UPS
Nominal Active Back-up Type of power Number - type Communication Dimensions HxWxD (mm) 88 x 440 x 150
power power time socket of output ports
White (VA) (W) (min) socket Net weight (kg) 5.5
3 103 30 FR 8 - FR Ambient Conditions
3 103 31 FR/DE/IT 8 - IEC Operating temperature (°C) 0 – 40
up to
800 480 USB HID Relative humidity (%) < 95% (non condensing)
3 103 32 15 FR/DE/IT 8 - DE/IT
Protection rating IP20
3 103 33 UK 8 - IEC
< 40
Noise at 1 m (dBA)
Black
Estimated content
3 110 16 FR 8 - FR of circular economy 37%
derived materials
3 110 17 up to FR/DE/IT 8 - IEC
800 480 USB HID Recyclability rate
3 110 18 15 FR/DE/IT 8 - DE/IT calculated using
the method described 73%
3 110 19 UK 8 - IEC in technical report
IEC/TR 62635*
NOTE: the stated backup times in minutes are estimated and may vary according to the load
characteristics, operating conditions and environment. Conformity
EN 62040-1, EN 62040-2,
Certifications EN 62040-3
DE/IT standard sockets
FR standard sockets
Rear sockets
INPUT
USB
16
Keor SPE tower
Line Interactive UPS - Single phase VI-SS
n Characteristics
General 3 110 60 3 110 61 3 110 62 3 110 63 3 110 64
Characteristics
Nominal Power (VA) 750 1000 1500 2000 3000
Active Power (W) 600 800 1200 1600 2400
Power Factor 0.8
Technology Line Interactive VI
Waveform Pure sinewave
Input
Number of input 1Ph
phases
3 110 60
Voltage (V) Nominal: 230 / Range: 175 - 288 @ full load
Frequency (Hz) 47-63Hz (50/60Hz auto-sensing)
Characteristics Output
• Power Factor: 0.8 Output Voltage 230, adjustable to 200/208/220/230/240
• User friendly LCD display
Frequency (Hz) 50 or 60Hz +/- 0.5 %
• Wide input voltage range and frequency
• Hot swappable battery Programmable Outlets YES (1-group programmable)
• Programmable extended quantity of outlets Number of output
• Overload, short circuit, back-feed, overtemperature protection 1Ph
phases
• Powerful built-in charger Batteries
• Cold start (DC power on)
• RS232 & USB - SNMP Slot Battery type Lead-acid sealed without maintenance (VRLA)
• EPO (Emergency Power Off) Battery replacement Front Access (Hot-swappable)
• 2 dry contacts Charging Time
• Compact size & light weight 6-8 hours
(0-90%)
Communication and management
Item UPS Keor SPE Tower
Screen and Five buttons, display and three-colored LED Bar
Nominal Active Back up Number Communication
power power time of sockets ports/slot signalling for real-time control of the status of the UPS
(VA) (W) (min) (10A/16A)
RS232 - USB - SNMP Slot - EPO (ROO)
IEC Communication 2-dry contacts
3 110 60 750 600 9 6/- USB - RS232 - SNMP
Electronic circuits against overloads and short-
3 110 61 1000 800 7 8/- USB - RS232 - SNMP Protections circuit, back-feed, emergency power off (EPO),
3 110 62 1500 1200 7 8/- USB - RS232 - SNMP overtemperature
3 110 63 2000 1600 7 8/- USB - RS232 - SNMP Physical characteristics
3 110 64 3000 2400 4 8/1 USB - RS232 - SNMP Dimensions 170x238x325 170x238x438
W x H x D (mm)
Item Accessories Net weight (kg) 14 14.5 18.9 23 26.5
Environmental conditions
3 110 78 10 A British Standard cable for 3 110 60 - 3 110 61 - 3 110 62
Operating temperature 0 - 40°C / +32°F - + 104° F
3 110 79 16 A British Standard cable for 3 110 63 - 3 110 64 Relative humidity 0-95% (Non-Condensing)
range (%)
NOTE: The stated back-up times in minutes are estimated and may vary according to the load
characteristics, operating conditions and environment. Storage temperature 0 ºC +50 ºC / +32 ºF to +122 ºF
Protection degree IP20
Acoustic Noise at
Keor SPE 750 - 1000 VA < 40
1m (dBA)
Estimated content
of circular economy 41%
derived materials
Recyclability
rate calculated
using the method
described in 78%
technical report
IEC/TR 62635*
3 110 60 3 110 61 Conformity
Reference product IEC/EN 62040-1, IEC/EN 62040-2,
Keor SPE 1500 - 2000 - 3000 VA standards IEC/EN 62040-3
* This value is based on data collected from a technological channel operating on an industrial
basis. It does not pre-validate the effective use of this channel for end-of-life of this product.
Item Accessories
3 109 52 Rack support bracket kit
3 109 53 External manual by-pass
3 110 78 3 110 70
10 A British Standard cable for 3 110 65 - 3 110 66 -
3 110 67 - 3 110 68 - 3 110 69
3 110 79 16 A British Standard cable for 3 110 70 - 3 110 71 -
3 110 72 - 3 110 73
3 110 72
3 110 71
NOTE: The stated back-up times in minutes are estimated and may vary according to the load
characteristics, operating conditions and environment.
In accordance with its policy of continuous improvement, the Company reserves the right to 3 110 73
change specifications and designs without notice. All illustrations, descriptions,
dimensions and weights in this catalogue are given as a guide only.
18
Keor SPE RT
Line Interactive UPS - Single phase VI-SS
n Characteristics
General specifications 3 110 65 3 110 66 3 110 67 3 110 68 3 110 69 3 110 70 3 110 71 3 110 72 3 110 73
Nominal Power (VA) 750 1000 1000 1500 1500 2200 2200 3000 3000
Active Power (W) 525 700 800 1050 1200 1980 1980 2700 2700
Power Factor 0.7 0.8 0.7 0.8 0.9
Rack Unit 1U 2U 1U 2U 3U 2U 3U
Technology Line Interactive VI
Waveform Pure sinewave
Input
Number of input phases 1Ph
Voltage (V) Nominal: 230 / Range: 175 - 288 @ full load
Frequency (Hz) 47-63Hz (50/60Hz auto-sensing)
Output
Output Voltage 230 V, adjustable to 200/208/220/230/240 V
Frequency (Hz) 50 or 60Hz +/- 0.5 %
Programmable Outlets YES (2-group for 1U) (1-group for 2U/3U)
Batteries
Battery type Lead-acid sealed without maintenance (VRLA)
Battery replacement Front Access (Hot-swappable)
Battery extension Only 2U/3U: YES (max. 4 pcs)
Legrand references N/A 3 110 74 N/A 3 110 75 3 110 76 3 110 77
Charging Time (0-90%) 6-7 hours
Communication and management
Screen and signalling Five buttons, display and three-colored LED Bar for real-time control of the status of the UPS
Communication RS232 - USB - SNMP Slot - EPO - 2-dry contacts
Electronic circuits against overloads and short-circuit, back-feed, emergency power off (EPO),
Protections
overtemperature
Physical characteristics
440 x 88 440 x 44 440 x 88 440 x 88 440 x 132 440 x 88 440 x 132
Dimensions W x H x D (mm) 440 x 44 x 513
x 440 x 557 x 440 x 600 x 500 x 600 x 500
Net weight (kg) 13.5 16.9 16.8 17.5 28.3 29.5
440 x 88
Battery cabinet dimensions W x H x D (mm) N/A N/A 440 x 88 x 440
x 440
Net weight (kg) - - 27.5 - 27.5 28.7
Environmental conditions
Operating temperature 0 – 40°C / +32°F – + 104° F
Relative humidity range (%) 0 – 95% (Non-Condensing)
Storage temperature 0 ºC +50 ºC / +32 ºF to +122 ºF
Protection degree IP20
Acoustic Noise at 1m (dBA) < 40 < 45 < 50 < 45 < 50 < 55
Estimated content of circular economy
41%
derived materials
Recyclability rate calculated using the
method described in technical report IEC/ 78%
TR 62635*
Conformity
Reference product standards IEC/EN 62040-1, IEC/EN 62040-2, IEC/EN 62040-3
*This value is based on data collected from a technological channel operating on an industrial basis. It does not pre-validate the effective use of this channel for end-of-life of this product.
3 108 77
3 107 85
3 103 60 + 3 107 78
3 108 35
Characteristics:
- Modular single-phase UPS Item Single cabinet - without batteries
- Power from 1250 to 10000 VA
Nominal Active Back-up time Number of
- On-Line double conversion VFI-111 power power (min.) cabinets
- Adaptable, expandable and redundant solutions in a single cabinet (VA) (W)
- Swift and simple maintenance and management
- Low environmental impact (high efficiency and reduced footprint) 3 103 51 1250 875 13 1
- Single or double cabinet UPS unit depending on the output power 3 103 53 2500 1750 13 1
- Wide range of input voltage and frequency ranges
- Operating frequency of 50 - 60 Hz with self-recognition mode 3 103 55 3750 2625 13 1
- Frequency converter 50 in - 60 out or vice versa 3 103 57 5000 3500 13 1
- Extension of the input frequency rate for operations with genset units
- Eco Mode operations (energy saving) Double cabinet - without batteries
- Load waiting mode operations (protection on demand)
- Output voltage adjustable in 1 volt steps from the front control panel Nominal Active Back-up time Number of
- Very low noise level power power (min.) cabinets
- Internal and external temperature reader (VA) (W)
- Controls ventilation depending on the temperature and load - 2
- Emergency remote shutdown option 3 103 60 + 3 108 59 5000 3500
3 103 63 + 3 108 59 6250 4375 - 2
Item Single cabinet (German standard) 3 103 66 + 3 108 59 7500 5250 - 2
Nominal Active Back-up time No. Weight 3 103 69 + 3 108 59 8750 6125 - 2
power power (min.) Cabinet (kg) 7000 - 2
(VA) (W) 3 103 72 + 3 108 59 10000
20
Megaline Rack
Modular single-phase double conversion UPS VFI
3 103 85 3 107 96
Characteristics:
- Modular single-phase UPS - Load waiting mode operations (protection on demand)
- Output from 1250 to 5000 VA - Output voltage adjustable in 1 volt steps from the front control panel
- Wide range of input voltage and frequency ranges - Very low noise level
- Operating frequency of 50 - 60 Hz with self-recognition mode - Internal and external temperature reader
- Frequency converter 50 in - 60 out or vice versa - Controls ventilation depending on the temperature and load
- Extension of the input frequency rate for operations with genset units - Emergency remote shutdown option
- Eco Mode operations (energy saving)
NOTE: The stated backup times in minutes are estimated and may vary according to the load characteristics, operating conditions and environment.
For the choice of communication accessories, see the dedicated section of this catalogue.
n Characteristics
3 103 42 3 103 43 3 103 44 3 103 45
3 103 46 3 103 47 3 103 48 3 103 49
3 103 50 3 103 52 3 103 54 3 103 56 3 103 60 + 3 103 63 + 3 103 66 + 3 103 69 + 3 103 72 +
General Characteristics 3 103 34 3 103 35 3 103 36 3 103 37 3 107 78 3 107 79 3 107 80 3 107 81 3 107 82
3 103 38 3 103 39 3 103 40 3 103 41
3 103 79 3 103 81 3 103 83 3 103 85
Single CABINET Double CABINET
and RACK
Nominal power (VA) 1250 2500 3750 5000 5000 6250 7500 8750 10000
Active power (W) 875 1750 2625 3500 3500 4375 5250 6125 7000
Max. expansion (VA) 5000 10000
Max. expansion (W) 3500 7000
Technology On-Line double conversion (VFI-SS-111)
Modular, expandable, redundant N+X with 1250 VA Power modules,
UPS Architecture contained in one single Cabinet/ Rack
Input
Nominal input voltage 230 V
Input voltage range 184 - 264 VAC at 100% load
Minimum operating voltage 100 VAC at 50% load
THD Input current < 3%
Input Power Factor > 0.99 from 20% load
Input frequency 50 Hz / 60 Hz ± 2% autosensing
Output
Output voltage 230 V ± 1%
Frequency output 50 Hz / 60 Hz synchronised
THD Output Voltage < 1% with non-linear load
Waveform Sinusoidal
Peak Factor 3:1
Efficiency up to 92%
Overload capacity 300% for 1 sec, 200% for 5 sec, 150% for 30 sec
Batteries
Backup time extension Yes
Accessories supplied
Automatic, internally synchronised, static and electromechanical
Bypass (for overloads and operating problems)
Alarms and signals Wide screen with 4 alphanumeric lines, multi-coloured status indicator, audible signalling
Communication ports 1 RS232 port2 logic level ports
Electronic devices for protection against overloads, short-circuits and excessive battery discharge.
Operation stops at end of Backup time. Inrush current limiter on start-up.
Protections Sensor for correct neutral switching.
Back-feed protection (electrical safety insulation of the input plug during battery-based operation).
EPO (emergency power off) contact.
IN/ OUT mains connection German standard/terminal connector with universal multi-socket outlet (Italian/German standard)
Mechanical characteristics
Net weight (kg) 23.5 34 43 53 24 + 50 26.5+57.5 29 + 65 31.5+72.5 34 + 80
Megaline Dimensions (HxWxD) (mm) 475 x 270 x 570 2 x 475 x 270 x 570
Megaline Rack Dimensions (HxWxD) (mm) 266 x 483 x 582 -
Power modules installed 1 2 3 4 4 5 6 7 8
Free power expansion slots 3 2 1 - 4 3 2 1 -
Installed battery kits 1 2 3 4 4 5 6 7 8
Free backup extension slots 3 2 1 - 6 5 4 3 2
Ambient conditions
Operating temperature (°C) 0 – 40
Protection rating IP20
Relative humidity (%) < 95% (non condensing)
Noise at 1 m from the unit (dBA) < 40
Certifications
Standards EN 62040-1, EN 62040-2, EN 62040-3
Warranty
Standard Warranty 2 years with the On Site formula batteries included, interventions c/o the installation location
22
Megaline and Megaline Rack
Modular single-phase double conversion UPS VFI
n Long backup time table for single and double cabinet versions
no. cabinets and dimensions
Model Power Back-up time Codes
HxWxD (mm)
Single Cabinet
1,250 VA 30’ 1x (270 x 475 x 570) 3 103 73
1,250 VA 52’ 1x (270 x 475 x 570) 3 103 74
1,250 VA 75’ 1x (270 x 475 x 570) 3 103 75
2,500 VA 22’ 1x (270 x 475 x 570) 3 103 76
2,500 VA 30’ 2x (270 x 475 x 570) 3 103 77
2,500 VA 52’ 2x (270 x 475 x 570) 3 103 52 + 3 107 78
2,500 VA 63’ 2x (270 x 475 x 570) 3 103 52 + 3 107 79
3,750 VA 18’ 1x (270 x 475 x 570) 3 103 78
3,750 VA 29’ 2x (270 x 475 x 570) 3 103 54 + 3 107 77
3,750 VA 44’ 2x (270 x 475 x 570) 3 103 54 + 3 107 79
3,750 VA 67’ 2x (270 x 475 x 570) 3 103 54 + 3 107 82
5,000 VA 22’ 2x (270 x 475 x 570) 3 103 56 + 3 107 76
5,000 VA 30’ 2x (270 x 475 x 570) 3 103 56 + 3 107 78
5,000 VA 46’ 2x (270 x 475 x 570) 3 103 56 + 3 107 81
5,000 VA 63’ 2x (270 x 475 x 570) 3 103 56 + 3 107 84
Double Cabinet
5,000 VA 22’ 2x (270 x 475 x 570) 3 103 60 + 3 107 80
5,000 VA 30’ 2x (270 x 475 x 570) 3 103 60 + 3 107 82
5,000 VA 46’ 3x (270 x 475 x 570)* 3 103 60 + 3 107 84 + 3 107 75
5,000 VA 63’ 3x (270 x 475 x 570)* 3 103 60 + 3 107 84 + 3 107 78
6,250 VA 20’ 2x (270 x 475 x 570) 3 103 63 + 3 107 81
6,250 VA 30’ 2x (270 x 475 x 570) 3 103 63 + 3 107 84
6,250 VA 47’ 3x (270 x 475 x 570)* 3 103 63 + 3 107 84 + 3 107 78
6,250 VA 60’ 3x (270 x 475 x 570)* 3 103 63 + 3 107 84 + 3 107 81
7,500 VA 18’ 2x (270 x 475 x 570) 3 103 66 + 3 107 82
7,500 VA 30’ 3x (270 x 475 x 570)* 3 103 66 + 3 107 84 + 3 107 76
7,500 VA 48’ 3x (270 x 475 x 570)* 3 103 66 + 3 107 84 + 3 107 81
7,500 VA 59’ 3x (270 x 475 x 570)* 3 103 66 + 3 107 84 (x2)
8,750 VA 20’ 2x (270 x 475 x 570) 3 103 69 + 3 107 84
8,750 VA 30’ 3x (270 x 475 x 570)* 3 103 69 + 3 107 84 + 3 107 78
8,750 VA 45’ 3x (270 x 475 x 570)* 3 103 69 + 3 107 84 + 3 107 83
8,750 VA 61’ 4x (270 x 475 x 570)* 3 103 69 + 3 107 84 (x2) + 3 107 78
10,000 VA 22’ 3x (270 x 475 x 570)* 3 103 72 + 3 107 84 + 3 107 76
10,000 VA 30’ 3x (270 x 475 x 570)* 3 103 72 + 3 107 84 + 3 107 80
10,000 VA 46’ 4x (270 x 475 x 570)* 3 103 72 + 3 107 84 (x2) + 3 107 76
10,000 VA 60’ 4x (270 x 475 x 570)* 3 103 72 + 3 107 84 (x2) + 3 107 81
* The configuration requires the use of a Y 3 108 60 connection cable (the number of cables required is equal to the no. of cabinets -2)
n Keor LP 1000
Accessories
Description
NOTE: the stated backup times in minutes are estimated and may vary according to the load
characteristics, operating conditions and environment.
For the choice of communication accessories, see the dedicated section of this catalogue.
24
Keor LP
Conventional UPS - Single phase On-line double conversion VFI
n Characteristics
3 101 54 3 101 56 3 101 58
General characteristics 3 101 55 3 101 57 3 101 59
Nominal power (VA) 1000 2000 3000
Active power (W) 900 1800 2700
Technology On-line double conversion VFI-SS-111
Waveform Sinusoidal
Architecture UPS with extendable Backup time
Input characteristics
Input voltage 230 V
Input frequency 45-65 Hz ±2 % Autosensing
Input voltage range 210 V÷240 Vac at 100% load
Input power factor > 0,99
Output characteristics
Output voltage 230 V ± 1 %
Efficiency Up to 90 %
Output frequency (nominal) 50/60 Hz synchronised
Peak factor 3:1
THD of output voltage < 3% with linear load
<105% ONLINE mode, 121÷150% for 10 sec., 106÷120% for 30 sec.,
Overload capacity: >151% instant transfer to bypass
Bypass Automatic, internal, synchronised, electromechanical (for overloads and operating problems)
Batteries
Backup time extension Sì
Backup time (min) 5
Communication and management
Screen and signalling Multi-coloured LED status indicator, alarms and audible signalling
Communication ports 1 RS232 serial port, 1 slot for network interface connection (ex. CS141)
Emergency Power Off (EPO) Yes
Remote control Software can be downloaded free of charge
Mechanical characteristics
Dimensions (H x W x D) (mm) 236 x 144 x 367 322 x 151 x 444 322 x 189 x 444
Dimensions of battery cabinet 322 x 151 x 444 322 x 151 x 444 322 x 151 x 444
(H x W x D) (mm)
Battery cabinet Net weight (kg) 31 31 31
Ambient conditions
Ambient operating temperature (°C) 0 ‑ 40
Relative humidity (%) 20 ‑ 80 non condensing
Noise at 1 m (dBA) < 50
Certifications
Reference product standards EN 62040-1, EN 62040-2, EN 62040-3
26
Daker DK Plus
UPS - double conversion online VFI
n Characteristics
General characteristics 3 101 70 3 101 71 3 101 72 3 101 73 3 101 75 3 101 74 3 101 76 3 101 77 3 101 78
Nominal power (VA) 1000 2000 3000 5000 6000 10000 10000
Active power (W) 900 1800 2700 5000 6000 10000 9000
Technology On-Line Double Conversion VFI-SS-111
Waveform Sinusoidal
UPS Architecture convertible tower and rack 19
Input
Input voltage 230 V 380V 3F+N
Input frequency 50-60 Hz ±5% Autosensing
305 - 485 Va.c.
Input voltage range 180 - 300 Va.c. at full load 170 - 280 Va.c. at full load at full load
THD Input current < 3%
Input power factor > 0.99 > 0.9
Output
Output voltage 230V ± 1%
Nominal output frequency 50/60 Hz (LCD screen settings) +/- 0,1%
Efficiency Up to 90% Up to 91% Up to 92% Up to 94% Up to 90%
Crest factor 3:1
THD Output Voltage < 3% with linear load
Output Voltage Tolerance ±1%
Internal automatic bypass Included
External maintenance bypass optional optional optional - - - - - -
Batteries
Backup time extension Yes
Communication and Management
LCD display with three buttons and five LEDs to monitor
Screen and signalling UPS status and main operating parameters in real time
Communication ports RS232, USB RS232
Remote control Available
Network interface slot Yes
Backfeed protection Yes
Remote emergency power Off Yes
(EPO)
Mechanical Characteristics
440x196
440 x 88 440x88 440x196 440x88
Dimensions HxWxD (mm) (2U) x 405 440 x 88 (2U) x 600 (4U)x680 (2U)x680 (4U)x680 (2U)x680 440x132 (3U) x680
*This value is based on data collected from a technological channel operating on an industrial basis. It does not pre-validate the effective use of this channel for end-of-life of this product.
n Characteristics
General characteristics 3 101 40 3 101 41 3 101 42 3 101 43
For the choice of communication accessories, see the dedicated section of this catalogue.
28
Daker DK Plus
Long backup times table
NOTE: the stated backup times in minutes are estimated and may vary according to the load characteristics, operating conditions and environment.
n Configuration
1000 VA 2 cabinet 2000 VA 2 cabinet 3000 VA 3 cabinet 6000 VA 2 cabinet 10000 VA 2 cabinet
L 2U + 4U L 2U + 2U L 2U +2U + 2U L 2U + 2U L 3U + 3U
TOWER
version
1000 VA 2 cabinet 2000 VA 2 cabinet 3000 VA 3 cabinet 6000 VA 2 cabinet 10000 VA 2 cabinet
H 2U + 4U (294mm) H 2U + 2U (196mm) H 2U + 2U + 2U (294mm) H 2U + 2U (196 mm) H 3U + 3U (294mm)
RACK
version
3 101 21 3 107 41
Characteristics:
- 3kVA to 10 KVA Capacity Range
- 1 Phase Input / 1 Phase Output
- IGBT Inverter - IGBT Rectifier
- High Efficiency
- Digital Signal Processor (DSP)
- High Input Power Factor (PFC)
- High Output Power Factor
- Low Input and Output Total Harmonic Distortion (THD)
- Generator Compatible Operation
- Standard IP31 Protection for Industrial Applications
- On Site Modular Paralleling Capability up to 4 Units (except 3kVA)
- Additional External Chargers for Long Back-Up Time Solutions (6-10kVA only)
- Availability of Different Communication Types
n UPS with isolation transformer built in
- User friendly diagnostic
- Advanced management and communication
- Integrated By-pass for maintenace
- LCD display with interactive menù
Battery cabinet
Description
30
Keor S
Conventional UPS - Single-phase On-line double conversion
n Characteristics
General characteristics 3 kVA 6 kVA 10 kVA
Nominal power (VA) 3000 6000 10000
Active power (W) 2400 5400 9000
Technology On-line double conversion
Waveform Sinusoidal
Architecture conventional UPS
Input characteristics
Input voltage 220V-230V-240V
Input frequency 45-65 Hz
Input voltage range 160V-288V 195V-280 V
THD of input current 6%
Input power factor > 0,99
Output characteristics
Output voltage 220V/230V/240V Adjustable from Front Panel
Output frequency (nominal) 50 /60 Hz Adjustable from Front Panel +/- 0,05%
Crest factor 2,5:1
THD of output voltage < 1,5% with linear load < 3% with non-linear load
10 seconds at 125%-150% 120 seconds at 100%-120%
Overload capacity 30 seconds at 106%-120% 30 seconds at 121%-150%
Efficiency in Eco mode 98%
Bypass - Automatic bypass and manual maintenance bypass
Batteries
Backup time extension Yes
Communication and management
LCD Display Available
1 RS232 serial ports, 1 USB port,
Communication Port 1 RS232 serial ports, modbus and SNMP optional
modbus and SNMP optional
Remote Management Available
Mechanical characteristics
Dimensions H x W x D (mm) 716 x 275 x 776
Dimensions battery cabinet H x W x D (mm) 716 x 275 x 776
Ambient conditions
Operating temperature (°C) 0 ‑ 40
Relative humidity (%) <95% (non condensing)
Protection index IP31
Noise at 1 m (dBA) < 50
Compliance
Reference product standards EN 62040-1, EN 62040-2, EN 62040-3
EFFICIENCY 95
93
The Legrand modular UPS guarantee 91
exceptionally high efficiency values, up to 4% 89
higher than the minimum values required by 87
the European Code of Conduct (92%). 85
96.5%
83
81
79
20 25 50 75 100
% load
Trimod HE
Code of Conduct (for UPS from 40 < 200 kVA)
Code of Conduct (for UPS from 20 < 40 kVA)
Redundancy on
single phase load R S T R S T
LOAD LOAD
Phase redundancy R S T R S T
In a system with three-phase
outputs, it is possible to create
redundancy on each individual
phase. If one of the power
modules fails, the other modules
for this phase take over from the
KO
faulty module.
L1 L2 L3 L1 L2 L3
R S T R S T
Control module
redundancy
In UPS that include several
control modules, the failure
of one of the control modules
results in the modules it
KO
controls being stopped.
However continuity of service
is assured by the automatic
distribution of the lost power
KO
over the other modules.
R S T R S T
34
EXCLUSIVE ROTATING
TOUCH SCREEN
DISPLAY
The Keor MOD has a 10”
touch screen display provides
a simplified control panel
packed with information,
alerts and settings and is
also equipped with interactive
icons to make navigation and
selection of the functions to be
controlled quick and simple.
The possibility of being able
to rotate the Display inwards
by 180° simplifies and speeds
up the configuration and
maintenance phases.
Attention to design
The elegance of the design and the skilful
choice of materials give the Legrand UPS
units a sleek and cutting-edge look.
Trimod HE
It consists of individual redundant
and self-configuring single phase
modules and has a nominal power
rating of 10 to 80 kVA.
Thanks to the construction
technology the various redundancy
levels can be set to always guarantee
maximum service continuity.
Trimod MCS
The Trimod MCS CPS (Central
Power Supply) is a single phase
and three-phase centralised
EN STANDARD
power supply system designed 50171
according to EN 50171 standards
and represents the ideal solution
Keor MOD for installation in buildings subject
to fire safety standards and,
It is an uninterruptible power supply specifically, to power emergency
based on three phase power modules, lighting systems. It can also
extremely compact and easy to handle. be used to power emergency
It delivers a nominal power from 25 to systems such as automatic fire
250 kVA, it can be connected in parallel extinguishing systems, emergency
with other units up to 600 kVA. detection and alarm systems,
smoke exhaust and carbon dioxide
Models up to 125 kVA have internal detection devices and specific
batteries for 5 minute backup time safety systems in sensitive areas.
at 100% load.
Keor MOD integrates perfectly
with the most critical applications such
as Data Centers.
36
Trimod HE
Modular three-phase double conversion UPS VFI
Characteristics:
- Modular three-phase UPS
- Power from 1 to 80 kVA
- On-Line double conversion VFI-SS-111
- High efficiency up to 96%
- Output factor 1
- Adaptable, redundant and scalable solutions (IN/OUT 3-1 phase configuration)
- Quick and simple maintenance
- Low environmental impact
- Diagnostics, monitoring, historical data and parameters that can be set
on the screen
- Reduced foot print and dimensions
- Taller cabinet to extend backup time and standard configurations
- Multi control board function
- Dual Input Function
- Hot Swap system
3 108 71
- Menu available in 7 languages
- Frequency converter in 40-70Hz out 50/60Hz (selectable)
- Operations with genset
- Three independent phase outputs
- Bypass line input
- Eco Mode
- Output voltage adjustable in 1 volt steps (190÷245V)
- Bypass speed regulation
- Event log complete with date and time
- Global and historic data of each power module
3 104 42 3 111 13
n Characteristics
3 104 15*
3 103 96 3 104 03 3 104 09 3 104 19 3 104 20 3 104 73
General Characteristics 3 104 18*
3 103 97 3 104 08 3 104 14 3 104 71 3 104 72 3 110 08
3 104 69
Nominal power (kVA) 10 15 20 30 40 60 80
Active power (kW) 10 15 20 30 40 60 80
Module power (kVA) 3.4 5 6.7 5 6.7 6.7 6.7
Technology On-Line Double Conversion VFI-SS-111
System Modular, expandable and redundant UPS system
Input specifications
380, 400, 415 3F+N+PE
Input voltage 380, 400, 415 3F+N+PE
(or 220, 230, 240 1F)
Input frequency 45-65 Hz (43,0 ÷ 68,4 Hz)
Input voltage range 400V +15%/-20% - 230V +15%/-20% 400V +15%/-20%
THD Input current < 3% ( at full load)
Compatibility with genset Yes
Input Power Factor > 0.99
Output Specifications
380, 400, 415 3F+N+PE
Output voltage 380, 400, 415 3F+N+PE
(or 220, 230, 240 1F)
Efficiency Up to 96%
Efficiency in Eco Mode 99%
Nominal output frequency 50/60 Hz selectable by the user ± 0,1% (standard), ±14 % (extended)
Peak factor 3:1
Waveform Sinusoidal
Output Voltage Tolerance ±1%
THD Output Voltage < 1%
Overload capacity 10 minutes at 115%, 60 seconds at 135%
Bypass Automatic bypass (static and electromechanical) and manual maintenance bypass
Batteries
Battery module Plug & Play
Battery series type/voltage VRLA - AGM /240 Vd.c.
Back-up time Configurable
Battery charger Smart Charge Technology. 3-stage advanced cycle
Independent battery configuration No Yes Yes with KIT
Communication and management
4 20-character rows, 4 menu navigation buttons,
Screen and signalling multi-colour LED status indicator, alarms and acoustic signals
Communication ports 2 RS232 ports, 1 logic level port, 5 floating contact ports, 1 interface slot
Back feed protection NC/NO auxiliary contact
Emergency Power Off (EPO) Yes
Remote control Available
Mechanical characteristics
Height A-B (mm) 1370 - 1650
Width (mm) 414 414 414 414 414
Depth (mm) 628 628 628 628 628
Number of Installed Power Modules 3 6 6 9 12
Installable battery drawers (A-B) Up to 12 - Up to 16 Up to 0 - 12 - - -
Net weight A-B (kg) Refer to the previous page, where there are the weights of the various configurations
Ambient Conditions
Operating temperature/humidity 0 - 40°C / 0 - 95% non condensing
Protection rating IP20
Noise at 1 m from the unit (dBA) 58-62
Estimated content of circular economy derived materials 37%
Recyclability rate calculated using the method
84%
described in technical report IEC/TR 62635**
Certifications
Standards EN 62040-1, EN 62040-2, EN 62040-3, EN 62040-4
Services
Installation User executable, modular architecture with “Plug & Play” power modules and batteries
Maintenance User executable, availability of optional services provided by the manufacturer
Ease of management Advanced diagnostic functions via the touch screen display
* Standard configurations with 3-3 distribution (multi IN/OUT settings available upon request)
** This value is based on data collected from a technological channel operating on an industrial basis. It does not pre-validate the effective use of this channel for end-of-life of this product.
38
Trimod HE
Long backup times table
Nominal power
Trimod HE Battery cabinet type Back-up time Dimensions HxWxD (mm) Weight (kg)
(kVA)
3 104 44 + 3 107 61 modular 10 78 2 x 1370 x 414 x 628 472
3 104 46 + 3 107 60 modular 15 33 2 x 1370 x 414 x 628 413
3 104 08 + 3 104 78 non modular 15 110 * 1370 x 414 x 628 + 1635 x 600 x 800 902
3 104 46 + 3 107 63 modular 15 57 2 x 1370 x 414 x 628 550
3 104 48 + 3 107 62 modular 20 35 2 x 1370 x 414 x 628 572
3 104 14 + 3 104 78 non modular 20 82 * 1370 x 414 x 628 + 1635 x 600 x 800 865
3 104 18 + 3 107 63 modular 30 12 2 x 1370 x 414 x 628 434
3 104 18 + 3 104 78 non modular 30 50 * 1370 x 414 x 628 + 1635 x 600 x 800 890
3 104 18 + 2 x 3 104 78 non modular 30 110 * 1370 x 414 x 628 + 2 x 1635 x 600 x 800 1645
3 104 19 + 2 x 3 107 63 modular 40 20 3 x 1370 x 414 x 628 801
3 104 19 + 3 108 10 non modular 40 33 * 1370 x 414 x 628 + 1635 x 600 x 800 925
3 104 19 + 2 x 3 104 78 non modular 40 82 * 1370 x 414 x 628 + 2 x 1635 x 600 x 800 1700
3 104 19 + 3 x 3 104 78 non modular 40 120 * 1370 x 414 x 628 + 3 x 1635 x 600 x 800 2430
3 104 19 + 3 x 3 107 64 modular 40 40 1370 x 414 x 628 + 3 x 1650 x 414 x 628 439
3 104 19 + 4 x 3 107 64 modular 40 60 1370 x 414 x 628 + 4 x 1650 x 414 x 628 1663
3 104 20 + 2 x 3 107 64 modular 60 15 1370 x 414 x 628 + 2 x 1650 x 414 x 628 942
3 104 20 + 4 x 3 107 63 modular 60 27 5 x 1370 x 414 x 628 1579
3 104 20 + 3 104 78 non modular 60 17 * 1370 x 414 x 628 + 1635 x 600 x 800 952
3 104 20 + 2 x 3 104 78 non modular 60 50 * 1370 x 414 x 628 + 2 x 1635 x 600 x 800 1715
3 104 20 + 3 x 3 104 78 non modular 60 80 * 1370 x 414 x 628 + 3 x 1635 x 600 x 800 2474
3 104 20 + 4 x 3 104 78 non modular 60 110 * 1370 x 414 x 628 + 4 x 1635 x 600 x 800 3234
3 110 08 + 2 x 3 104 70 non modular 80 20 1650X414X628+2X1635X600X800 1622
3 110 08 + 2 x 3 104 78 non modular 80 30 1650X414X628+2X1635X600X800 1782
3 110 08 + 3 x 3 104 78 non modular 80 47 1650X414X628+3X1635X600X800 2572
3 110 08 + 4 x 3 104 78 non modular 80 67 1650X414X628+4X1635X600X800 1782
* Configurations with long life battery cabinets.
310470 LONG LIFE BATTERY CABINET MODEL A - 710 kg - 600x800x1635 mm
310478 LONG LIFE BATTERY CABINET MODEL b - 790 kg - 600x800x1635 mm
NOTE: the stated backup times in minutes are estimated and may vary according to the load characteristics, operating conditions and environment.
EN STANDARD
50171
3 108 71
NOTE: the stated backup times are estimated and may vary according to the load characteristics, operating conditions and environment.
For the choice of communication accessories, see the dedicated section of this catalogue.
40
Trimod MCS
CPS Modular three-phase double conversion VFI
n Characteristics
93+ 3 109 94+ 3 109 95+ 3 109 96+ 3 109 97+ 3 109 98+ 3 109 99+
General Characteristics 3 109 90 3 109 91 3 109 92 33109 2x 2x 3x 4x
106 18 3 106 19 3 104 78 3 104 70 3 104 78 3 104 78 3 104 78
Nominal power (kVA) 3 5 6.7 10 15 20 30 40 60 80
Active power (kW) 3 5 6.7 10 15 20 30 40 60 80
Active power according to EN50171 (kW) 2.88 4.16 5.58 8 12.5 16.7 25 33.3 50 66.7
Technology On-Line Double Conversion VFI-SS-111
System Modular, expandable and redundant UPS system
Input specifications
380, 400, 415 3F+N+PE *
Input voltage 220,230,240 1F+N+PE 380, 400, 415 3F+N+PE
(o 220, 230, 240 1F)
Input frequency 45-65 Hz (43,0 ÷ 68,4 Hz)
Input voltage range 230V +15%/-20% 400V +15%/-20% - 230V +15%/-20% 400V +15%/-20%
THD Input current < 3% ( at full load)
Compatibility with power supply units Yes
Input power factor > 0.99
Output Specifications
380, 400, 415 3F+N+PE *
Output voltage 220,230,240 1F+N+PE 380, 400, 415 3F+N+PE
(o 220, 230, 240 1F)
Efficiency Up to 96%
Efficiency in Eco Mode 99%
Nominal output frequency 50/60 Hz selectable by the user ±2 % (standard), ±14 % (extended)
Peak factor 3:1
Waveform Sinusoidal
Output voltage tolerance ±1%
THD output voltage < 1%
Overload capacity 120% continuous, 10 minutes at 135%, 60 seconds at 150%
Bypass Automatic bypass (static and electromechanical) and manual maintenance bypass
Batteries
Battery module Plug & Play
Type Long Life
Back-up time 1h (settable as needed)
Battery charger 80% autonomy in 12h - Smart Charge technology. 3-stage advanced cycle
Communication and management
4 20-character rows, 4 menu navigation buttons,
Screen and signalling multi-colour LED status indicator, alarms and acoustic signals
Communication Ports 2 RS232 serial ports, 1 logic level port, 5 floating contact ports, 1 interface slot
Back feed protection NC/NO auxiliary contact
Emergency Power Off (EPO) Yes
Remote management Available
Mechanical characteristics
1650 x 1650 x
1650 x 1370 x
Dimensions HxWxD (mm) 1370 x 414 x 628 414 x 628 414 x 628 414 x 1370 x 414 x 628 414 x
628 628
Net weight kg 202.5 265.5 327.5 273.5 344.5 115 136 134 158.5 222
1370x 1650x
Battery cabinet dimensions HxWxD (mm) - - - 414x 414x 600x 800x1635
628 628
Battery cabinet net weight (kg) - - - 257 375 790 710 790
Installable battery drawers 8 12 16 - - - - - - -
Ambient Conditions
Operating temperature/humidity 0 - 40°C / 0 - 95% non condensing
Protection rating IP20
Noise at 1 m from the unit (dBA) 58-62
Conformity
Certifications EN 62040-1, EN 62040-2, EN 62040-3, EN 50171
Services
Installation User executable, modular architecture with “Plug & Play” power modules and batteries
Maintenance Availability of optional services provided by the manufacturer
Ease of management Advanced diagnostic functions via the touch screen display
* Standard configurations with 3-3 distribution (multi IN/OUT settings available upon request)
3 104 80
General features:
- Just two cabinet configurations (up to 125 kW and up to 250 kW)
- Internal Backup time up to 125 KW
- UPS system capacity up to 600 kW
- Rotating 10” touch screen display
- Reduced battery charging times
- Double conversion efficiency up to 96.8% (power module efficiency)
- Efficiency in ECO mode up to 99%. Keor MOD 125 Keor MOD 250
- Output power factor = 1 with additional distribution with additional distribution
- Modular redundancy in N+1 configuration
- Controlled noise level with integrated UPS switching devices. with integrated UPS switching devices.
- Multicoloured status bar LED
- Parallelable system up to 24 power modules
- Hot-swappable modules
- Decentralised by-pass.
- Intelligence distributed between modules
Item UPS - empty power cabinets
Power Installable Distribution Weight
(kW) battery drawers (kg)
n Characteristics
General specifications
Nominal power (kVA) 25 50 75 100 125 150 175 200 225 250
Active power (kW) 25 50 75 100 125 150 175 200 225 250
Module power (kW) 25
Classification On-Line double conversion VFI-SS-111
No. Power modules 1 2 3 4 5 6 7 8 9 10
System Modular, expandable and redundant UPS system
Input specifications
Input voltage 400V 3F+N+PE
Input frequency 45-65 Hz (43.0 ÷ 68.4 Hz)
Input voltage range 400V +15%/-20% - 230V +15%/-20%
THD input current < 3% ( at full load)
Compatibility with power supply units Yes
Input power factor > 0.99
Output Specifications
Output voltage 380, 400, 415V
Efficiency (power module) Up to 96.8%
System efficiency Up to 96.5%
Efficiency in Eco mode 99%
Nominal output frequency 50/60 Hz selectable by the user ±1 % (standard), ±14 % (extended)
Crest factor 3:1
Waveform Sinusoidal
Output voltage tolerance ±1%
THD output voltage <0.9% with linear load
Overload capacity 10 minutes at 125%, 60 seconds at 150%
Bypass Automatic bypass (static and electromechanical) and manual maintenance bypass
Batteries
Battery module Plug & play
Battery series type/voltage VRLA - AGM 12 V, 9 Ah - 11 Ah
Autonomy Configurable
Battery charger Smart charge technology. 3-stage advanced cycle
Independent battery configuration Yes, maximum 5 sets of independent batteries (configurable as common or separate units)
Communication and management
Display 10-inch rotating colour touch screen
2 x RS485 ports (one for external accessories), 10 input floating contacts,
Communication ports
8 output floating contacts, 1 interface slot, USB host port
Back feed protection NC/NO auxiliary contact
Emergency Power Off (EPO) Yes
Cold start push-button Yes
Remote management Available
Mechanical characteristics
Height (mm) 1990
Width (mm) 600 (900 for solutions with additional column)
Depth (mm) 1000
Installable power modules Up to 5 Up to 10
Installable battery drawers Up to 10 —
Net weight kg 256 233
Ambient Conditions
Operating temperature/humidity 0 - 40°C / 0 - 95% non condensing
Protection rating IP20
Maximum audible noise at 1 m from
50-65
the unit (dBA)
Estimated content of circular
43%
economy derived materials
Recyclability rate calculated using
the method described in technical 74%
report IEC/TR 62635*
Conformity
Certifications EN 62040-1, EN 62040-2, EN 62040-3, EN 62040-4
Services
Installation Modular architecture with “plug & play” power modules and batteries
Maintenance Availability of optional services provided by the manufacturer
Ease of management Advanced diagnostic functions via the touch screen display
44
THE PERFECT
BALANCE BETWEEN
DIMENSIONS
AND POWER
The supplied internal batteries,
with a capacity of up to 80 kVA,
avoid additional costs for the
purchase of external battery
cabinets, help reduce the
space occupied and simplify
installation.
Keor XPE
It is a complete scalable UPS system based on 250 or
300 kVA power units that can be combined with others
to achieve the required power level (up to 2.1 MVA) or
create redundant configurations.
Keor XPE It is the ideal solution for Data Center and
high power applications.
46
SPECIAL CARE
FOR DESIGN
Keor HPE
Keor HPE is the perfect solution
for critical medium and large power
applications and is available
Keor T Evo from 60 to 600 kVA versions.
Its nominal powers of from 10 to 60 kVA Boasting attention to design
provide a simple and compact solution for and a smart display, it includes
classic applications in tertiary, trade and advanced battery charging and
industry sectors. Keor T Evo is scalable, management features that
parallelable and equipped with a display guarantee top battery performance
and multicoloured led bars that allow and maximum operating life.
for swift UPS status checks.
Keor Compact
With a rated power of 10-15-20 kVA, this is an
easy-to-install UPS with wheels and colour
touchscreen with user-friendly graphics and
navigation windows. Thanks to its small dimensions,
Keor Compact is ideal for installation even in small
technical rooms. Parallel connections for redundant
configurations make this UPS the perfect solution
also for critical applications.
CONVENTIONAL THREE-PHASE UPS CATALOGUE 47
Keor Compact
Conventional UPS - On-line three-phase double conversion VFI
Characteristics:
- PFC power-factor correction (input PF>0.99)
- 4.3” user friendly touch screen display
- Wide range of input voltages and frequencies
- Dual Input
- Cold Start
- Embedded backfeed protection
- Smart communication ports and SNMP management capability
- Parallelable system with up to 6 units
- Built-in battery for standard autonomy
- Extended backup time with battery cabinets
- Overload and short-circuit protection
- Powerful built-in loader
- RS232, dry contacts
- Compatibility with gensets
- Compact dimensions, lightweight and low noise
- Reduced footprint: 0.22 m2
3 111 00 - Wheels for ease of handling
Item UPS
Nominal
power
Power
active
Dimensions
W x D x H (mm)
Weight
(kg)
n Dimensions (mm)
(kVA) (kW)
Accessories
Dimensions
Description
890
W x D x H (mm)
311101 10 11 0
311101 + 1 x 311095 10 50 1
311101 + 2 x 311095 10 87 2
311101 + 3 x 311095 10 126 3
311103 15 7 0
311103 + 1 x 311096 15 40 1
890
890
311103 + 2 x 311096 15 67 2
311103 + 3 x 311096 15 99 3
311105 20 6 0
311105 + 1 x 311097 20 28 1
311105 + 2 x 311097 20 57 2
311105 + 3 x 311097 20 81 3
* 0 = UPS with internal batteries only.
NOTE: the stated backup times in minutes are estimated and may vary according to the
load characteristics, operating conditions and environment.
For the choice of communication accessories, see the dedicated section of this catalogue.
48
Keor Compact
Conventional UPS - On-line three-phase double conversion VFI
n Characteristics
General Characteristics Keor Compact 10 Keor Compact 15 Keor Compact 20
Nominal power (kVA) 10 15 20
Active power (kW) 9 13.5 18
Technology On-Line Double Conversion VFI-SS-111
Waveform Sinusoidal
Architecture Stand Alone or Distributed with parallelable system with up to 6 units
Efficiency up to 95%
Efficiency in ECO mode up to 98.5%
Input
Nominal input voltage 400V (3Ph+N+PE)
Nominal voltage (Ph-Ph) ±20% @100% load, -40/+20% @50% load
Input frequency 40-70 Hz
THD Input current <3% at full load
Dual Input yes
Compatibility with Power Supply Units yes
Input Power Factor >0.99
Output
Output voltage 380, 400, 415V (3Ph+N+PE)
Output voltage tolerance ± 1% static load
Nominal output frequency 50 /60 Hz (Adjustable from the front panel)
Output frequency tolerance ± 1 Hz / ± 3 Hz adjustable synch Mains for Bypass; ± 0.01% Free Run
Peak factor 3:1
THD Output voltage <2% (with linear load), <5% (with non-linear load)
Output power factor 0.9
Overload capacity 60 min at 110%, 10 min at 125%; 1 min at 150%
Bypass Automatic and maintenance bypass
Batteries
Cold Start yes
Battery Type VRLA
Internal batteries yes
Communication and management
Display 4.3” colour touch-screen display.
Communication ports RS232, 4 programmable relay contacts, RS485 (optional), network interface slot
Backfeed protection Integrated
Alarms and signals Alarms and audible warnings
Emergency Power Off (EPO) yes
Remote control available
Mechanical characteristics
Ventilation Forced with fan from the front to the rear
Maximum heat dissipation
600 900 1300
(100% of the W load, battery recharging)
Colour RAL9017 (black-cabinet) RAL9003 (white - control panel)
Dimensions W x D x H (mm) 260 x 850 x 890
Weight (without battery) (kg) 74 76 76
Weight (with batteries) (kg) 149 166 176
Ambient Conditions
Operating temperature (°C) 0 - 40°C (recommended temperature for longer useful battery life: 20-25°C)
Relative humidity 20-95% (not condensing)
Protection rating IP20
Noise at 1 m from the unit (dBA) < 52
Estimated content of circular 39%
economy derived materials
Recyclability rate calculated using the method 71%
described in technical report IEC/TR 62635*
Conformity
Certifications IEC/EN 62040-1, IEC/EN 62040-2, IEC/EN 62040-3, IEC/EN 62040-4
*This value is based on data collected from a technological channel operating on an industrial basis. It does not pre-validate the effective use of this channel for end-of-life of this product.
Characteristics:
- Output from 10 to 60 kVA
- New Keor T Eco up to 20 kVA and power factor 1
- Three-phase UPS
- 3 level Switching technology
- IGBT Rectifier and inverter
- High efficiency n Keor T Evo 40-60 with
- Digital signal processor (DSP) external battery cabinet
- High Input Power Factor Correction
- 3.5” TFT touch screen panel
- High output Power Factor
- Low input and output total harmonic distortion values (THD)
- Compatibility with gensets
- Parallelable system with up to 4 units
- Communication ports
Item UPS
Nominal power Back-up time Dimensions Weight
(kVA) (min.) (mm) (kg)
3 110 23 10 57 1650 x 400 x 800 426 3 101 32 5 4,5 1345 x 400 x 800 118
3 110 24 15 0 1345 x 400 x 800 127 3 101 33 7,5 6,75 1345 x 400 x 800 132
3 110 25 15 14 1345 x 400 x 800 268 3 101 34 10 9 1345 x 400 x 800 134
3 110 26 15 22 1345 x 400 x 800 288 3 102 78 15 13,5 1345 x 400 x 800 140
3 110 27 15 33 1650 x 400 x 800 431 3 102 79 20 18 1650 x 600 x 900 255
3 110 28 20 0 1345 x 400 x 800 134 3 102 96 30 27 1650 x 600 x 900 277
3 110 29 20 10 1345 x 400 x 800 275
3 110 30 20 15 1345 x 400 x 800 296 Accessories
3 110 31 20 37 1650 x 400 x 800 477 3 109 18 Battery cabinet empty (up to 60 blocks 55 Ah)
3 110 32 30 0 1345 x 400 x 800 141 3 109 21 Internal cables kit for battery cabinet empty
3 110 33 30 10 1345 x 400 x 800 302 (for 60 blocks 55 Ah)
3 110 34 30 13 1650 x 400 x 800 441 3 109 11 Battery drawers kit for Keor T Evo 10-30 kVA
3 110 35 30 22 1650 x 400 x 800 484 (up to 60 blocks 7-9 Ah)
3 110 36 40 0 1650 x 600 x 900 238 3 109 12 Battery drawers kit for Keor T Evo 40-60 kVA
(up to 60 blocks 7-9 Ah)
3 110 37 40 10 1650 x 600 x 900 538
3 109 13 Internal battery cables kit for battery
3 110 38 40 15 1650 x 600 x 900 573 drawers Keor T Evo 10-30 kVA
3 110 39 40 25 1650 x 600 x 900 740 3 109 14 Internal battery cables kit for battery drawers
3 110 40 60 0 1650 x 600 x 900 258 Keor T Evo 40-60 kVA
3 110 41 60 10 1650 x 600 x 900 590 3 109 15 Parallel kit/UPS (PCB + 5 m cable)
3 110 42 60 15 1650 x 600 x 900 755 3 109 87 Keor T Evo Battery Cabinet A
NOTE: the stated backup times in minutes are estimated and may vary according to the load 3 109 88 Keor T Evo Battery Cabinet B*
characteristics, operating conditions and environment.
For the choice of communication accessories, see the dedicated section * To be used in multiples of 2.
of this catalogue.
50
Keor T Evo
UPS - On-line three-phase double conversion VFI
n Characteristics
Keor T Evo Keor T Evo Keor T Evo Keor T Evo Keor T Evo Keor T Evo
Model 3Ph 400V (380-400-415V) 3Ph 10 15 20 30 40 60
Nominal power (kVA) 10 15 20 30 40 60
Active power (kW) 10 15 20 30 40 60
Keor T Evo 208V Keor T Evo 208V Keor T Evo 208V Keor T Evo 208V Keor T Evo 208V Keor T Evo 208V
3Ph version 208V (200-208-220V) 5 7,5 10 15 20 30
Nominal power (kVA) 5 7,5 10 15 20 30
Active power (kW) 4,5 6,75 9 13,5 18 27
General characteristics
Technology On-line double conversion VFI-SS-111
Waveform Sinusoidal
Architecture Stand alone or distributed parallel up to 6 units
Input Characteristics
Input voltage 400V (3Ph+N+PE)* / 200-208-220V (3Ph+N+PE)**
Input frequency 45-65 Hz
Input voltage range (Ph-Ph) ±20%* / ±15%**
THD of input current <5% at full load
Compatibility with diesel generators Yes
Input power factor >0.99
Output characteristics
Output voltage 380, 400, 415V (3Ph+N+PE)* / 200-208-220V (3Ph+N+PE)** (Adjustable from front panel)
Efficiency up to 96% *
Efficiency in ECO mode up to 98,5%
Output frequency (nominal) 50 /60 Hz (Adjustable from front panel)
Output frequency tolerance ±0,1%Synch with Mains; ±0,01% Free Run
Crest factor up to 3:1
THD of output voltage < 2% at full linear load
Output power factor 1* / 0,9**
Output voltage tolerance ± 1%
Overload capability 10 min at 125%; 60 sec at 150%
By-pass Builtin automatic and mainteinance bypass
Batteries
Battery type VRLA – AGM Maintenance free
Internal batteries Yes
Battery test Yes Automatic or Manual
Battery recharge profile IU (DIN41773)
Communication and management
LCD Display Touch screen, led bar status, live synoptic view for real time
Communication Ports RS232, RS485, GenSet, Programmable 4 relay contacts, ModBus
Back feed protection Internal back feed protection device is standard
Audible alarm Acoustic alarms and warnings
Net interface slot optional SNMP card
Emergency Power Off (EPO) Yes
Remote management Available
Physical characteristics
1345/1650 x 400 x 800*
Dimensions H x W x D (mm) 1650 x 600 x 900
1345 x 400 x 800**
Dimensions battery cabinet 1650 x 800 x 900
H x W x D (mm)
Ambient conditions
Operating temperature (°C) 0‑40
Relative humidity (%) 20‑95% not condensing
Protection index IP20
Noise at 1 m (dBA) < 58 < 60
Estimated content of circular 39%
economy derived materials
Recyclability rate calculated using
the method described in technical 71%
report IEC/TR 62635***
Compliance
Reference product standards EN 62040-1, EN 62040-2, EN 62040-3
* for 3Ph 400V Version
** for 3Ph 208V Version
*** This value is based on data collected from a technological channel operating on an industrial basis. It does not pre-validate the effective use of this channel for end-of-life of this product.
n Keor HP 60-80-100-125-160
n Keor HP 200-250-300
Characteristics:
- 60-800kVA Capacity
- 3 Phase Input / 3 Phase Output
- IGBT-Based Rectifier and Inverter
- High Efficiency
- Digital Signal Processor (DSP)
- High Input Power Factor (PFC)
- High Output Power Factor
- Batteries recharging compensation with temperature n Keor HP 400
- Inverter Isolation Transformer
- Low Input and Output Total Harmonic Distortion (THD)
- Genset operation compliant
- On Site Modular Paralleling Capability up to 6 Units
- Availability of Different Communication types
- Optimized cooling system
Options
Description
For the choice of communication accessories, see the dedicated section of this catalogue.
52
Keor HP
Conventional UPS - Three-phase On-line double conversion VFI
n Characteristics
General characteristics 60 80 100 125 160 200 250 300 400 500 600 800
Nominal power (kVA) 60 80 100 125 160 200 250 300 400 500 600 800
Active power (kW) 54 72 90 112.5 144 180 225 270 360 450 540 720
Technology On-line double conversion VFI-SS-111
Waveform Sinusoidal
Architecture Conventional UPS, parallelable up to 6 unit
Input characteristics
Input voltage 380-415 V 3Ph+N
Input frequency 50-60 Hz ± 10% autosensing
Input voltage range 400 V -20% / + 15%
THD of input current <3%
Configurable for synchronism between the input and output frequencies,
Compatibility with diesel generators
even for the highest frequency variations
Input power factor >0,99
Output characteristics
Output voltage 380, 400, 415 V 3Ph+N selected
Efficiency up to 95%
Output frequency (nominal) 50/60 Hz selected ± 0,001%
Crest factor 3:1
THD of output voltage <5% (with non-linear load)
Output voltage tolerance ± 1% (with balance load)
Overload capacity 10 minutes at 125%, 60 seconds at 150%, 10 seconds at 200%
Efficiency in Eco mode 98% >98%
Built-in Automatic
Bypass Built-in Automatic and Maintenance By-pass
(optional Maintenance Bypass)
Batteries
Backup time extension Scalable with additional battery cabinets
Battery type VRLA - AGM Maintenance-free Lead Acid Batteries
Battery test Automatic or manual
Battery Recharge Profile IU (DIN41773)
Communication and management
Four LED’s to show status at a glance.
LCD Display
Four menu-driven interface buttons. Four status at a glance LEDs
Communication Ports RS232 and USB serial ports (Optional RS485)
Audible Alarm Acoustic alarms and warnings, configurable delays
Configuration Setting Auto configuration by firmware, or manual by service engineer
Net Interface Slot Built-in dry contact PCB, optional SNMP card
Emergency Power Off (EPO) Yes
Remote Management Available
Battery temperature probe Yes
Physical characteristics
1920 x 2020 x 2020 x 1920 x
Dimensions H x W x D (mm) 1670 x 815 x 825 1905 x 1220 x 855 1990 x 2440 x 2440 x 3640 x
965 950 950 950
Net Weight (kg) 570 600 625 660 715 970 1090 1170 1820 2220 2400 3600
1900x1400x860
Dimensions battery cabinet 1900x1400x830 (50 batteries) (50 batteries) 1900 x 2800 x
H x W x D (mm)
860 -
1900x2800x830 (100 batteries) 1900x2800x860 (100 batteries)
(100 batteries)
Ambient conditions
Operating temperature (°C) 0 – 40
Relative humidity (%) <95% not condensing
Protection index IP20
Noise at 1 m (dBA) < 60 <62
Estimated content of circular economy
11%
derived materials
Recyclability rate calculated using the
method described in technical report 69%
IEC/TR 62635*
Certifications
*This value is based on data collected from a technological channel operating on an industrial basis. It does not pre-validate the effective use of this channel for end-of-life of this product.
Reference product standards EN 62040-1, EN 62040-2, EN 62040-3, EN 62040-4
Characteristics:
- Power from 60 to 600 kVA
- Three-phase UPS
- IGBT Rectifier
- High efficiency
- Digital signal processor (DSP)
- High Input Power Factor Correction (PFC)
- Output Power Factor 1
- Battery recharge, dynamic, intermittent with temperature compensation n Keor HPE 200-250-300 kVA
- Low input and output total harmonic distortion values (THD)
- Compatibility with gensets
- Parallel operations with up to 6 units
- Communication ports
- Optimised cooling system
Model UPS
Nominal Active Back-up time Dimensions Net weight
power power (min) H x W x D (mm) (kg)
(kVA) (kW)
Accessories
9 535 16 Parallel interface *
9 535 17 Interface for MODBUS RS485
- Empty battery cabinets
Options
Synchronism kit on two UPS**
Synchronism kit on two parallel UPS**
Isolation transformer
7” touch display (for Keor HPE 60-160)
IP 21 Kit
Common battery kits
* For parallel configurations involving 4 or more units, please contact your Service representative for
configuration guidance.
** to create two independent synchronous electrical lines (typical in Tier III, IV systems)
NOTE: the stated backup times in minutes are estimated and may vary according to the load
characteristics, operating conditions and environment.
For the choice of communication accessories, see the dedicated section of this catalogue.
54
Keor HPE
Conventional UPS - On-line three-phase double conversion VFI
n Characteristics
General Characteristics 60 80 100 125 160 200 250 300 400 500 600
Nominal power (kVA) 60 80 100 125 160 200 250 300 400 500 600
Active power (kW) 60 80 100 125 160 200 250 300 400 500 600
Technology On-Line Double Conversion VFI-SS-111
Waveform Sinusoidal
UPS Architecture Conventional UPS parallel operations with up to 6 units
Input
Characteristics
- On-Line Double Conversion VFI SS 111
- 3-level IGBT technology - Transformer Free
- Output power factor = 1 without downgrading up to 40°C in continuous
operation mode (VFI)
- Configurable internal redundancy (N + 1 or N + X).
- Hot maintainable modules
- Hot scalability (optional)
- Up to 96,4% efficiency VFI even at low power
- ECO mode up to 99% of efficiency.
- Built-in backfeed protection
- Automatic battery test feature.
- Genset compatibility with Adaptive Ramp-in
- Compact design.
- Low audible noise.
In/Out-Bypass Power unit Distribution cabinet - Synch 2N
Module Up to 7 units (optional)
Components UPS
Nominal Active Dimensions
n Dimensions
power power HxWxD (mm)
(kVA) (kW)
770 110
IOBM 600 600 600 1002x979x2100
IOBM 750 750 750 1450x979x2100
IOBM 900-1000 1000 1000 1500x979x2100
IOBM 1200-1500 1500 1500 1850x1000x2100
957
985
IOBM 1800-2100 2100 2100 2300x1200x2100
Options
Description
Future Scalability
Hot Scalability
Input Line: Dual/Single
Connection Entrance: Bottom/Top
Connection Type: Cable/Busbar 2101
Grounding System: TNC/TNS
1670
Battery cabinets
Battery switch fuse box
Synchronisation box
MODBUS RS485 card
Ethernet card with network interface
Please contact Legrand for further details on the configurations and accessories.
For the choice of communication accessories, see the dedicated section of this catalogue.
56
Keor XPE
Scalable UPS - Online three-phase double conversion VFI
n Characteristics
General Characteristics IOBM 600 IOBM 750 IOBM 900 IOBM 1000 IOBM 1200 IOBM 1250 IOBM 1500 IOBM 1800 IOBM 2100
Nominal power (kVA) 600 750 900 1000 1200 1250 1500 1800 2100
Power Unit power (kVA) 300 250 300 250 300 250 300 300 300
Number of power units (+1 redundant) 2+1 3+1 3+1 4+1 4+1 5+1 5+1 6+1 7
Technology On-Line Double Conversion VFI-SS-111
Decentralised logic, centralised static bypass, scalable, redundant,
Architecture hot-swap service (optional hot plug)
Input
Input voltage 400 Vac three-phase (rectifier), 380/400/415 Vac three-phase (Bypass)
Input frequency 50/60 Hz; range 45-65 Hz
Input Voltage Range (Ph-Ph) -20%, +15% (rectifier); ±10% (bypass)
THD Input current < 3%
Compatibility with genset Yes
Input power factor > 0.99
Output
Output voltage 380, 400, 415V (3Ph+N+PE)
Online Efficiency up to 96.4%
Efficiency in GREEN Mode up to 99%
Nominal output frequency 50 /60 Hz (Adjustable from the front panel)
Peak factor up to 3:1
THD of Output voltage < 1% with linear load
Output Power Factor 0.7 which reaches 0.5 in delay without downgrading
Output voltage adjustment VFI Static ± 1%; Dynamic Class 1 IEC/EN 62040-3
Overload capacity Inverter: 125% for 5 min, 150% for 30 sec;
Bypass
Type Automatic static without interruption, manual bypass optional
Input voltage 380-400-415V ± 20%; (3Ph+N+PE)
Input frequency 50-60Hz ± 10%
Rated current (A) 870 1090 1304 1450 1739 1810 2175 2609 3044
Max. LCW 50 kA IEC 62040-1 standard (100 kA optional)
Batteries
Battery type VRLA, NiCd, Li-Ion
Connecting the battery Distributed or centralised
Communication and management
LCD Display 10’’ Touch screen, 1024x600 pixels
Communication ports RS232, USB, RS485, network interface slot
Input and auxiliary contact Remote Emergency Power Off (REPO), diesel mode, temperature probe, battery circuit breaker.
External automatic switch auxiliary contact: battery, external maintenance bypass,
signal ports. remote output transfer in bypass mode
Output signal ports 5 dry contacts, external BackFeed
Mechanical characteristics
Connection lines Wired TNC or TNS 3PH output, rectifier and bypass (single input optional)
Input and connection type Bottom (top as optional), cable (busbar as optional)
Colour RAL 9003 (white) on the front panel of the IOBM; RAL 9005 (black) body and side panels of all cabinets
2770x970x 4970x980x 5370x980x 7580x1200x 8460x1200x
UPS dimensions WxDxH (mm)* 4090x970x2100 6250x980x2100
2100 2100 2100 2100 2100
UPS weight (kg)* 2250 3150 3300 4000 4250 4900 5200 6400 7300
Ambient conditions
Operating temperature (°C) 0 - 40 °C (recommended temperature for longer useful battery life: 20-25°C)
Relative humidity (%) 20-95% (non condensing)
Protection rating IP20 (IP21 Optional)
Noise at 1 m from the unit (dBA) < 65
Estimated content of circular economy
derived materials 20%
Recyclability rate calculated using the
method described in technical report 60%
IEC/TR 62635*
Conformity
Certifications IEC/EN 62040-1, IEC/EN 62040-2, IEC/EN 62040-3
* Weights and dimensions depend on the configuration chosen and refer to the complete basic system (no redundancy, no hot swapping).
**This value is based on data collected from a technological channel operating on an industrial basis. It does not pre-validate the effective use of this channel for end-of-life of this product.
58
UPSaver
Scalable High-Power UPS up to 2.67 MVA
Characteristics
• Hot swappable 333 kVA power units on VFI mode
• Hot scalable 333 kVA power units to 2.67 MVA
• 97.2% efficiency
• Flexibility in system design and installation
• Power parallel scalable up to 21 MVA
• Low audible noise level <65 dB
• Top busbar entry
• Low input capacitive power for genset flexibility
• Peak shaving capable
• Lithium battery compatible
Optionals
Description
Hot Scalability
Input Line: Dual/Single n UPSaver 1000 kVA Full
Connection Entrance: Bottom/Top
Connection Type: Cable/Busbar
Grounding System: TNC/TNS
Icw limitation kit
Battery set: Centralized/Distributed
Accessories
Description
Battery Cabinets
Battery fuse switch box
Synch Box
Net Interface Ethernet Cards
n Characteristics
General specifications IOBM 670 IOBM 1000 IOBM 1340 IOBM 1670 IOBM 2000 IOBM 2340 IOBM 2670
Nominal Power = Active Power (kW) 670 1000 1340 1670 2000 2340 2100
Power Unit power (kW) 333 333 333 333 333 333 333
Number of Power Units (+1 if Redundant) 2+1 3+1 4+1 5+1 6+1 7+1 8
Technology On-line double conversion VFI-SS-111
Architecture Centralized Static Bypass, Scalable, Redundant, Hot Service (Hot Swap Optional)
Input
Input Voltage 400 Vac 3-phase (rectifier), 380/400/415 Vac 3-phase (Bypass)
Input Frequency 50/60 Hz; range 45-65 Hz
Input Voltage Range (Ph-Ph) -20%, +15% (rectifier); ±10% (bypass)
THD of input current < 3%
Compatibility with Diesel Generators Yes
Input power factor > 0.99
Output
Output Voltage 380-400-415 Vac 3-phase with neutral
Efficiency Online up to 97.2%
Efficiency in UHE mode up to 99%
Output frequency (nominal) 50 /60 Hz (Adjustable from front panel)
Output frequency tolerance ±0,1%Synch with Mains; ±0,01% Free Run
Crest Factor up to 3:1
THD of output voltage < 1% at full linear load
Output power factor up to 1, without power derating
Output voltage Regulation VFI Static ± 1%; Dynamic: IEC/EN 62040-3, Class 1
Inverter: 105% continuous at 30°C, 125% for 10 min; 150% for 1 min;
Overload Capability bypass: 110% continuous; 150% for 1 min; 700% for 100 ms; 1000% for 10 ms
Bypass
Type Static Automatic no break, Manual Bypass optional
Input Voltage 380-400-415V ± 20%; (3Ph+N+PE)
Input Frequency 50/60Hz ± 10%
Nominal Current (A) 971 1449 1942 2420 2899 3391 3870
Max Icw 50 kA as per IEC 62040-1 (100 kA Optional)
Batteries
Battery/Storage Compatibility VRLA, NiCd, Li-Ion
Battery Connection Distributed or Centralized
Communication and management
Control Panel Display 10’’ Touch screen, 1024x600 pixels
Communication ports Serial RS232 and USB; ModBus-RTU (RS485). Net Card Slot (SNMP & ModBus-TCP/IP) (Optional)
Remote emergency power off (REPO), diesel mode, Temperature Probe, battery circuit breaker. Auxiliary contact
Input signal ports and aux.contact. of external circuit breakers: battery, external maintenance bypass, output remote transfer to bypass mode
Output signal ports 5 dry contacts, external BackFeed
Physical characteristics
Connection Lines Hardwired 3PH TNC or TNS Output, rectifier and bypass (single input as optional)
Connection Entrance and Type Bottom (top as optional), cable (busbars as optional)
Color RAL9005 (Black) RAL9003 (White)
3800 x 970 x 4450 x 970 x 6550 x 970 x 7200 x 970 x 7650 x 1200 x 8800 x 1200 x
UPS dimensions WxDxH (mm)* (***)
2150 2150 2150 2150 2150 2150
UPS weight (kg)* 2140 2710 4205 4775 5770 6630 (***)
Environmental conditions
Operating Temperature (°C) 0 - 40 °C (Recommended temperature for longer Battery Life: 20-25°C)
Relative Humidity Range 20-95% (Non-Condensing)
Protection degree IP20 (IP21 Optional)
Acoustic Noise at 1m (dBA) < 65
Estimated content of circular economy 32%
derived materials (%)
Recyclability rate calculated using the
method described in technical report 90.2%
IEC/TR 62635 (%)**
Compliance
Reference product standards IEC/EN 62040-1, IEC/EN 62040-2, IEC/EN 62040-3, IEC/EN 62040-4
(*) Full option version including top busbar entry module, main switches, hot swap distribution modules. (**) Conditions apply. (***) Contact our sales team.
(****) This value is based on data collected from a technological channel operating on an industrial basis. It does not pre-validate the effective use of this channel for end-of-life of this product.
60
BATTERY
CABINET
For all three-phase UPS.
ACCESSORIES CATALOGUE 61
Battery cabinet
For all three-phase UPS
n Characteristics
General characteristics
Nominal Voltage 800 Vdc
Battery segregation Internal panel in Polycarbonate
Switches and protection Internal bottom front side
access
Fuse Holders Switch with NH fast
Disconnection and protection fuses (sized accordingly with
devices * Battery Power)
Fuse holder Open/Close Auxiliary Micro Switch
signal*
Cable Entrance bottom sides (both left and right)
3 106 57 up to 20 batteries 105 Ah 3 109 82 up to 62 batteries 105 Ah Cable connections On Fuse holder terminals
Max Cable side entrance 3x 150mm2
Universal battery cabinets for all three-phase Legrand UPS from 10kVA Front door with key lock and
up to 800kVA power range. The Battery cabinet is designed to house Cabinet Access removable sides and rear panels
standard VRLA Batteries of capacity range from 24Ah to 105Ah (C10).
The battery cabinets are available in 5 different mechanical Shelter Bent Metal Sheet 20/10
dimensions, are able to contain various combination of Batteries, up Thickness
to maximum 63 blocks, connected in series and parallel, with positive, Shelves Bent Metal Sheet 30/10
negative and middle point poles and with max DC voltage of 800Vdc. Thickness
Protection Degrees IP20 (Optional IP21)
Item EMPTY BATTERY CABINET* Colour RAL 7016
Cabinet Dimensions TOT Indicative Standard UPS Compatibility
Standard IEC-EN 62040-1
(mm) Weight Battery No. Of
(kg) Capacity Blocks
(Ah)
62
COMMUNICATION
ACCESSORIES
AND SOFTWARE
ACCESSORIES CATALOGUE 63
Accessories
Management software
n Local protection
Protects one station only (PC or server) and must be installed
at a distance of less than 12 metres (RS232) or 5 metres (USB)
RS232
Pack Cat. Nos. Software
USB
Description
UPS Management
1 free UPS Management Software
Software
download* Set of applications for real-time control of the operation
of the UPS and to ensure the integrity of the systems on n Extended local protection
the computers supplied by this UPS.
Free download from the Legrand UPS website. Protects multiple stations (PC or server) but all must be dependent on
the COMPUTER that controls the UPS.
1 free RCCMD
download Software enabling a computer to receive and execute,
using the TCP/IP protocol, all the remote commands
sent by the management systems of the UPS. RS232 LAN
An RCCMD licence is necessary for each computer to
be controlled. The software can be downloaded free USB
from Internet.
UPS Management Software Agent RCCMD
free UNMS
download* “WEB based” application capable of real-time
supervision of the status of all UPS, via the
management systems of the UPS and the TCP/IP n Protection via TCP/IP network
protocol. License for 25 UPS. Enables control of all the stations that can communicate
with the network interface. The management of the system
1 3 108 92 UNMS can be supervised by all licensed users.
UNMS licence for 50 UPS
1 3 108 93 UNMS
UNMS licence for 150 UPS RS232/
Internal Network
RCCMD
slot interface
LAN
*Licence for 25 UPS
Any network
interface CS141
RCCMD
Agent RCCMD
RCCMD
n Centralised protection
Using the UNMS supervision software, it is possible to control all the
UPS connected to a TCP/IP network via any network interface that
supports SNMP v2 (standard RFC1628).
RS232/
Internal Network
slot interface
LAN/WAN
RS232/
Network
Internal UNMS
interface
slot
64
Accessories
Network interfaces CS141
n CS141 Characteristics
RS232
3 109 32 3 109 34
Model A B
CS141B SK X
CS141 X X*
CS141 SK X X*
CS141M X X**
CS141M SK X X**
ACCESSORIES CATALOGUE 65
Accessories
Sensors and other accessories
COM 1
Interface
3 109 00 3 108 98 3 109 03
network
COM 2
TCP/IP
UPS
LAN/WAN
SensorManager II
3 108 99 3 109 02
66
Accessories
Network interfaces
CS102 +
Wi-Fi dongle Wi-Fi
Wi-Fi
3 110 58
Network
switch
Network
3 110 59 cable
CS102
Pack Cat. Nos. Network interface CS102
Network interfaces for UPS management via LAN or
Wi-Fi connection. MODBUS over IP
The Wi-Fi dongle allows the UPS to be connected HTTP/HTTPs
to the data network without additional cables. The Program execution
network interfaces CS102 is able to continuously
control the UPS operations and handle multiple events SNMP, SNMP Trap management
(power failure, overload, bypass, anomaly, etc.) Sending e-mails (SMTP)
and consequently to carry out a series of actions, Log file, historical data file
such as, for instance: Performing computer shutdown
- Saving of event logs complete with date and time
- Saving of main operating data trends complete with
date and time LIST OF OPERATING SYSTEMS SUPPORTED BY THE SOFTWARE
- Sending of emails
- Display of pop-up messages, shutdown operations - Linux
and custom commands on remote computers (it - Windows
is necessary that the CS102 shadown client
software agent is installed on these computers)
- Switching ON and OFF the UPS
- Sending of “Wake on LAN (WOL)” signals
- SNMP protocol support
- Sending of SNMP trap messages
- Data display and configuration via internet browser
- Firmware downloadable free of charge from the
Internet
- 10/100Mbit Base-T Ethernet connection (half-duplex
and full-duplex) with self-recognition function
- DHCP function
The card is housed in a dedicated UPS slot.
Compatible with Daker DK Plus, Keor SPE,
Keor S, Keor LP, Keor Line RT, Keor T, Keor T Evo,
Keor Compact
1 3 110 58 CS102
Network interface
1 3 110 59 CS102 SK + Wi-Fi dongle
Network interface with USB dongle to enable Wi-Fi
connection.
ACCESSORIES CATALOGUE 67
COMMUNICATION ACCESSORIES COMPATIBILITY TABLE
UPS Management
CS141 SK CS141B SK CS141 CS141M CS141M SK CS102 CS102 SK
Software
Free 3 109 30 3 109 31 3 109 32 3 109 34 3 109 35 3 110 58 3 110 59
Keor PDU ✓
Keor SP ✓
Keor SPX ✓
Niky S ✓ ✓ ✓
Keor LINE RT ✓ ✓ ✓ ✓ ✓ ✓
Keor SPE ✓ ✓ ✓
Keor LP ✓ ✓ ✓ ✓ ✓ ✓
Daker DK Plus ✓ ✓ ✓ ✓ ✓ ✓
Keor S 3000 ✓ ✓ ✓ ✓ ✓ ✓
Keor S 6000 - 10000 ✓ ✓ ✓ ✓ ✓ ✓
Megaline / Megaline Rack ✓ ✓ ✓
Keor Compact ✓ ✓ ✓ ✓ ✓ ✓
Keor T ✓ ✓ ✓ ✓ ✓ ✓
Keor HP ✓ ✓ ✓ ✓
Keor HPE ✓ ✓ ✓ ✓
Trimod HE ✓ ✓ ✓ ✓
Keor MOD ✓ ✓ ✓
n Other accessories
3 109 30 - CS141 SK ✓* ✓* ✓*
3 109 32 - CS141 ✓* ✓* ✓*
3 108 99 – Sensor Manager ✓ ✓ ✓ ✓
* Not for simultaneous use
68
CUSTOMER SERVICES
70
FOLLOW US
ALSO ON