Parking on 2 levels with pit
Kipparker N 3000 comfort S/D
The classic even more user friendly
with less platform inclination
Made in Germany
Areas of application
residential buildings, single garages above ground and prefabricated garages
Both platforms
free space 135 25 free space for gate
are inclined 140 115 25 free space for gate
Load per platform
max. 2000kg 90
Load per wheel
max. 500kg
295
295
200 (210)
to GaVo
,5°
pprox. 4
incline a
Dimensions in cm
entrance 300 max. 1%
10 10
slope
,5°
pprox. 6
min 18, B 25
incline a
155
150
concrete
wall opening 10 x 10 for
hydraulic and electrical lines
300
in case of intermadiate walls 530 (525 available on request)
2% incline to DIN 1045-1
drainage channel 10 x 10
+3 with collecting pit 50 x 50 x 20
• Tolerances to construction dimensions 0.
• Optionally: 155 cm pit at front; 160 cm pit at rear (pit edge), 295cm inside height
Vehicle Data
8 162 65 55 90 8 162 115
10
25 20 15
HO HU
46
150* 46
154* 14
56
22 60 20 56 22 27
38 14
38 60
90 max. 290 120
90 max. 290 120
500 500
max. car width 190cm, max. load per platform 2000kg, max. load of wheel 500kg
*HO platform above *HU platform below
Height of the car in HO is 150 cm. HO is not suitable Height of the car in HU is 154cm. Neither the
for station wagons, low clearance cars or tuned cars standard or the extra height version is suitable
(spoilers or roker rail). In the extra height version with for station wagons, low clearance cars or tuned
310 cm inside height station wagons can park in the cars (spoilers or roker rail). For these vehicles we
above level. recommend the parking systems Liftparker N 4400
and N 4600 with horizontal accessible platforms.
Note: The total car height including roof rail and antenna fixture must not exceed the mentioned max. height.
Width dimensions • Garages
All dimensions are minimum dimensions. All dimensions in cm. Tolerances to the German Norm VOB part C (DIN
18330, 18331) and DIN 18202 are to be considered.
Note: Dimensions do not include the dimensions of the hydraulic unit. Dimensions of the hydraulic unit and the
switch cabinet shown in page 4 below, are to be considered in the planning.
partition walls
S - system S - system D - system S - system
A1 driving lane according
A1 A1
to local requirements
S-system for 2 cars D-system for 4 cars D- and S-system for 6 cars
width A1 260 270 280 width A1 490 500 510 520 530 width A1 750 780 810
width* 230 240 250 width* 460 470 480 490 500 width* 460/230 470/240 480/250
* gives clear platform width * gives clear platform width * gives clear platform width
building pillars inside of the pit
S S
D D D E D E
min. 15 min. 15 min. 15
max.
max. 100 max. 100
100 driving lane
B1 B2 B1 B2 B1 B2 according to
local requirements
S-system for 2 cars D-system for 4 cars D- and S-system for 6 cars
width B1 255 265 275 width B1 485 495 505 515 525 width B1 745 775 805
width B2 250 260 270 width B2 475 485 495 505 515 width B2 735 765 795
width* 230 240 250 width* 460 470 480 490 500 width* 230+460 240+480 250+500
* gives clear platform width * gives clear platform width * gives clear platform width
building pillars in front of the pit
S S D D
D S D S
min. 20 min. 20 min. 20
driving lane
according to
C1 C2 C1 C2 C1 C2
local requirements
S-system for 2 cars D-system for 4 cars D- and S-system for 6 cars
width C1 250 260 270 width C1 480 490 500 510 520 width C1 740 770 800
width C2 240 250 260 width C2 470 480 490 500 510 width C2 730 760 790
width* 230 240 250 width* 460 470 480 490 500 width* 230+460 240+480 250+500
* gives clear platform width * gives clear platform width * gives clear platform width
Features in the scope of delivery
Scope of supply
S/D-systems with 2 platforms, 2 columns, 2 hydraulic
cylinders and hydraulic block
Width of parking space
Width of parking space 230cm and depth of pit 155/150cm
1 key switch as standard
2 emergency stop
Safety devices
Key switch • synchronizing device for safe operation even with
Key switch incl. emergency stop, dead man´s unequal load distribution on the platform
control type with brief operating instructions • entering wedge for easy drive-in and parking
and wiring to hydraulic unit. • locking device prevents lowering by pipe breakage
• fixation of the car parking systems and hydraulic
unit with HD-anchors, wiring and impact dowels
• railings to avoid risk of falling onto the platform,
insofar as necessary
Note: Safety guards against shearing and squeezing
have priority and must be provided by the Buyer.
Protection against corrosion
Corrosion protection version „Classic“ of driving plates
by continuous line-galvanizing to DIN EN 10142/10143.
Hydraulic unit Corrosion protection version „Classic Plus“ of driving
Hydraulic unit “Silencio“ with tubing and plates by line-galvanizing to DIN EN 10142/10143
wiring to the installation. The oil submerged (depending on the market specific needs zinced and
motor “Silencio“ is extremely quiet and smooth powder coated sheet metal included in the scope of
running. The motor-pump assembly is sound supply).
absorbent.
Location
• between or behind two systems in the pit
on a 2 m high support, see picture above
• if there is no space between or behind the
systems – wall-mounted
• single systems: power supply placed directly
on the lower platform, in the front left side
Dimensions incl. switch cabinet
• 1 – 2 systems: 65 cm x 25 cm x 60cm
• 3 – 5 systems: 115cm x 25 cm x 60 cm
Driving plates
The hydraulic unit can be used for up to 5 Driving plates as trapezoidal sheet plates as standard,
Car Parking Systems. options see “Extra Equipment“.
Extra Equipment and Options
Width of parking space
• button lifting Width of parking space 240cm and 250cm is recommended
• button lowering for even more vehicle comfort
• emergency stop
• key switch with
key interlock
Vehicle weight
Optional vehicle weight: 2500kg – not by inclined parking
Berlin control system/Fire brigade spaces. We recommend to use for these vehicles our
Interlocked key switch, removal of the key solutions Liftparker N 4400 and N 4600 with horizontal
only in the upper basic position. accessible platforms.
Additional sound insulation
• structure-borne noise package to comply with DIN 4109
and adherence to sound insulation-measure Rw ´57
• sound insulatin hood to minimize airborne sound
Hydraulic
• HVLP-oil for high fluctuations in temperature
Installation of garage gates
• ramp when door facing is not available to install the door
slide rail, pit length must be 535cm, at the minimum
Driving plates
Alu-bulb-plate in the walking area even more Protection against corrosion
user friendly when walking and driving. • Corrosion protection version „Premium“ of driving
plates by individual piece-galvanizing to DIN ISO 1461
• Corrosion protection version „Premium Plus“ of driving
plates by individual piece-galvanizing to DIN ISO 1461
and coating of the top surfaces
Tips
• We recommend a maintenance contract.
• Attendance and cleaning according to recommendations
or in regular intervals.
Catwalks
Positioning on the left side of the parking
space even more comfortable, when walking
to the driver´s door. 1,5 mm zinced sheet,
surface area coined. The catwalks are screwed
to the driving plates, available with corrosion
protection version „Classic“ or „Classic Plus“.
Dimensions approx. 350 cm x 31/41cm (L x W)
Interfaces to be performed by the Buyer
Foundation
Foundation works exactly to size, clean and dry is to be completed by the start of the installation. Bonded anchors
for high foundation requirements shall be provided if neccessary, available also as option.
Foundation plan F1
F1
F2 F2
single-system double-system F3 F3
F1 13 kN 30 kN F4 F4
F2
F2 +/- 2 kN +/- 2 kN F3
F6
F3 2 kN 7 kN
F5 F5
F4 8 kN 15 kN
F5 F4 F1
F5 10 kN 10 kN
F6 F6
F6 +/- 5 kN +/- 10 kN
10 10
The pit must be executed in compliance with the designated forces. The forces and loads are transfered to the
foundation by bearing plates with an area of 150cm². The bearing plates are fixed with metal expansion anchors.
The drill hole depth is approx. 14 cm. All walls in the pit below the entrance level must be of concrete.
Electrical Data General costumers duties
• supply line to main switch 5 x 2,5mm² or according • level surface (L x W) 50cm x 20cm to attach the
to local requirements, fuse protection 3 x 16 amp, control panel, close to the system, outside the
slow platform area
• lockable main switch, near to hydraulic unit but • safeguarding according to DIN EN 294
outside of the pit, completed at the beginning of • lighting according to DIN 67528, illumination of
installation, height approx. 180 cm above entrance parking lots and buildings for parking
level (color requirements to EN 60204-1, 10.7.4, • at the edge of the pit a 10cm wide, yellow-black
color red) marking according to ISO 3864
• capacity of the hydraulic unit: 400volt, 50 hz, • wall opening 10cm x 10cm for hydraulic and
threephase motor 3,0 kW electrical lines in case of intermadiate walls
• electrical potential equalisation (foundation • compliance with installation requirements as per
grounding steel-construction to VDE 0100 T410) quotation
lockable main switch safeguarding to DIN EN 294 marking pit edge
Width dimensions • Garages with doors
single system for 2 cars
TA = seat-engaging surface for doors
The dimensions must be agreed with
S - system S - system S - system the door manufacturer on site.
TA
TA
LB LB LB ST ST
DB DB DB
width of parking space door entrance width DB reveal LB pillar ST
5 5
230 237 12 25
5
240 250 12 25
250 250 15 30
double system for 4 cars
D - system D - system D - system
driving lane
LB LB LB ST ST
according to the
DB DB DB local requirements
width of parking space door entrance width DB reveal LB pillar ST
460 460 15 30
5
470 475 12 25
480 475 17 5 35
5
490 500 12 25
500 500 15 30
Electric Installation
2
Installation diagram 1
7 12 10
8 9
11
13
11
4
5
14 15
14
Technical modifications reserved. Modifications in the scope of supply reserved to the manufacturer. Version 21112007 · NK
Item Performance Quantity Designation Location Frequency
1 on site 1 fuse or automatic circuit in the feed cable 1 per hydr. unit
3 x 16 amp slow to DIN VDE 0100 part 430
2 on site 1 supply line 5 G 2,5 mm² or feed cable to 1 per hydr. unit
according to local requirements main switch
3 on site 1 lockable main switch near to hydraulic unit 1 per hydr. unit
4 on site each foundation earth connector corner pit floor/
10 m rear wall
5 on site 1 potential equalisation to DIN EN 60204 from foundation earth 1 per hydr. unit
connector to the system
6 Nussbaum 1 hydraulic unit with 3-phaze motor 230/400volt, 50 hz 3 kW
7 Nussbaum 1 supply line 5 G 2,5 mm² with from main switch 1 per hydr. unit
marked wires and protective conductor to hydraulic unit
8 Nussbaum 1 control line 2 x 1
9 Nussbaum 1 control element with emergency stop
10 Nussbaum 1 control line 4G1
11 Nussbaum 1 control line 4G1
12 Nussbaum 1 control line 2 x 1
13 Nussbaum 1 hydraulic valve lifting and lowering
14 Nussbaum 1 hydraulic valve lifting and lowering by installation in ranks
15 Nussbaum 1 control element for each further system
The items 6 – 15 are included in the scope of supply, unless otherwise specified in the offer/order.
Otto Nußbaum GmbH & Co. KG · Korker Str. 24 · 77694 Kehl-Bodersweier
Tel.: +49(0)78 53/8 99-0 · Fax: +49(0)78 53/ 899-114 · www.nussbaum-parking.de