KCE Parameters

The document provides a detailed parameter list for the KCECPU system, including various settings related to elevator operation such as door types, timings, and connectivity options. Each parameter is accompanied by its ID, name, minimum and maximum values, and a description of its function. This information is crucial for configuring and maintaining the elevator system effectively.

Uploaded by

qg8u2s2iu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
143 views19 pages

KCE Parameters

The document provides a detailed parameter list for the KCECPU system, including various settings related to elevator operation such as door types, timings, and connectivity options. Each parameter is accompanied by its ID, name, minimum and maximum values, and a description of its function. This information is crucial for configuring and maintaining the elevator system effectively.

Uploaded by

qg8u2s2iu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 19

1374567D03 KCECPU parameter list, KMI, KCEPU ARM5 SW release version 15.4.1.

Min
ID Parameter Name Max Value Description
Value
258 Door Sides At Floor 0 15 Shaft layout
0 = Dummy floor
1 = A side door exist
2 = B side door exist
3 = A & B side doors exist
4 = C side doors exist
5 = A & C side doors exist
6 = B & C side doors exist
7 = A & B & C side doors exist
Note! Values copied from setup data after setup drive.

259 Floor Markings 0 4294967295 Floor markings for floors 1 ... 250
Default markings 1,2,3,...

260 Lowest Floor 1 249 Lowest Floor

261 Highest Floor 2 250 Highest Floor

262 Main Floor 1 250 Main Floor

280 Roll Call Direction 0 2 Roll Call (RC) direction (type)


0 = Roll call for car and machine room networks only
1 = Roll call for shaft from up to down
2 = Roll call for shaft from down to up
Note! RC required when parameter value changed.

282 Roll Call Start Floor 0 250 Roll Call (RC) start floor
0 = according to shaft layout (standard way)
1 ... 250 = Specific Roll call start floor

300 Lift ID 0 30 Elevator ID in group

301 Group ID 0 500 Elevator Group ID

304 Connectivity Type 0 1 E-Link and Connectivity


0 = disabled
1 = enabled
Note! Value 1 shall be used with KCECPUc

305 Lift name 0 4294967295 Manual configuration of the lift name at site.
Maximum number of allowed characters is 3.
Allowed characters are [A-Z] [a-z] and [0-9].

399 FCB IO mapping 0 8 Defines I/O map used on FCB board for OSI/HSL/IUL and Up Call outputs
0 = I/O configuration file in use
1 = FC control, up & dn buttons separated, OSI in use.
2 = DC/PB control, dn button used for calls. OSI & HSL in use.
3 = DC/PB control, dn button used for calls. IUL & HSL in use.
4 = DC/PB control, dn button used for calls. IUL & OSI in use.
5 = DC/PB control, dn button used for calls. HSL & OSI in use.
6 = Up & dn buttons connected together. OSI in use.
7 = Up & dn buttons connected together. HSL in use.
8 = Up & dn buttons connected together. IUL in use.

408 Stuck Button Service Interval 1 30 Stuck call buttons service interval in minutes.

515 Door Type 0 6 0 = no door


1 = automatic door, parallel interface to door control
2 = automatic door, serial interface to door control
3 = swing door at landing with manual car gate in car
4 = swing door at landing with safety ray in car
5 = swing door at landing + automatic door in car, parallel interface to door
control
6 = swing door at landing + automatic door in car, serial interface to door
control

516 Door Open Time 10 600 Basic door open time in 0.1s steps

1/19
1374567D03 KCECPU parameter list, KMI, KCEPU ARM5 SW release version 15.4.1.8

Min
ID Parameter Name Max Value Description
Value
517 Door Open Time Main Add 0 300 Additional door time at main floor in 0,1 s steps

518 Door Open Time Ldg Add 0 300 Additional door time to landing call in 0,1 s steps

519 Door Reopen Time 1 150 Door reopen time in 0,1 s steps

524 Door Ensured Time For SRC 1 100 Ensured door open time after photocell cut in 0,1 s steps

525 Door Ensured Time For QCC 1 100 Ensured door open time after new car call in 0,1 s steps

526 Door Open Limit Supervision Time 10 300 Door open limit supervision time in 0,1 s steps

527 Door Close Limit Supervision Time 10 300 Door close limit supervision time in 0,1 s steps

528 Door Opening Time 10 300 Door opening time in 0,1 s steps when door open limit not in use

529 Door Open Limit In Use 0 1 Door open limit in use


0 = not in use
1 = in use

530 Door Close Limit In Use 0 1 Door close limit in use


0 = not in use
1 = in use

532 Door Nudging Time (NUD) 1 1200 Nudging time in 0,1 s steps

533 Door Nudging Short Time 1 1200 Shortened Nudging time in 0,1 s steps

534 Door Open Too Long Time 1 3000 Timeout for door open too long fault in 0,1 s steps

536 Door Closed Torque 0 3 Door torque control (close command)


0 = torque released when door closed, default
1 = torque not released when door closed/locked
2 = torque released even door locked
3 = torque released at door close limit

541 Door Contact (Car) Filter Time 0 50 Filtering time for car door contact bouncing in 0,1 s steps

542 Door Open Delay 0 50 Door opening delay at stopping in 0,1 s steps

545 Door Torque Reset Time 1 200 Door torque time when elevator vacant
Defines time to keep close command (torque) ON still after car door contact
closed in 0,1 s steps

546 Door Retiring Ramp Full Voltage Time 0 200 Retiring ramp magnet control full voltage time
Defines time to keep full voltage in RR circuitry when RR energized in 0,1 s
steps
0 = Full voltage in use all the time
1 ... 200 = Full voltage time (0,1s ... 20s)

547 Door Close Limit Polarity 0 1 Polarity of door close limit contact while door closed (CDL C)
0 = Normally Open (NO) contact
1 = Normally Closed (NC) contact

548 Door Open Limit Polarity 0 1 Polarity of door open limit contact while door open (CDL O)
0 = Normally Open (NO) contact
1 = Normally Closed (NC) contact

549 Door Opened Torque 0 2 Door torque control when door is open
0 = torque released when door fully opened
1 = torque not released when door fully opened
2 = torque is released 3 seconds after door fully opened

551 Door Open Time for DOE B 10 6000 Door open time for extended door open button DOE B/T in 0,1 s steps

552 Door Contact Bouncing Filter Time 0 50 Filtering time for swing door contact (H4) bouncing in 0,1 s steps
(swing door)

2/19
1374567D03 KCECPU parameter list, KMI, KCEPU ARM5 SW release version 15.4.1.8

Min
ID Parameter Name Max Value Description
Value
553 Door Opening Delay with Car Door 0 40 Delay for car door opening if LOA or retiring ramp is in use by 0,1 s steps
Lock (LOA)

554 Door DOE buzzer 0 1 DOE buzzer control, (DOE *I)


0 = buzzer disabled
1 = buzzer enabled

556 Door Full Speed Time Closing 0 100 Door closing time at full speed with timer controlled (inverter) door in 0,1 s
steps
0 = Full speed used permanently
1 ... 100 = time for full speed (0,1s ... 10s)

557 Door Full Speed Time Opening 0 100 Door opening time at full speed with timer controlled (inverter) door in 0,1
s steps
0 = Full speed used permanently
1 ... 100 = time for full speed (0,1s ... 10s)

559 Door Retiring Ramp Control at Stop 0 1 Defines retiring ramp control for manual landing door at stopping phase
when automatic car door is in use.
0 = retiring ramp de-energizes before car door opening
1 = retiring ramp de-energizes when car door fully opened

560 Door Retiring Ramp Control at Start 0 1 Defines retiring ramp control for manual landing door at starting phase
when automatic car door is in use.
0 = retiring ramp energizes when landing door and car door are closed
1 = retiring ramp energizes when landing door is closed

564 Door Close Button Polarity 0 1 Door Close Button (DCB) polarity
0 = Normally Open (NO) contact
1 = Normally Closed (NC) contact

565 Door Open Button Polarity 0 1 Door Open Button (DOB) polarity
0 = Normally Open (NO) contact
1 = Normally Closed (NC) contact

566 Door Photocell Polarity 0 1 Photocell (SRC) polarity


0 = Normally Open (NO) contact
1 = Normally Closed (NC) contact

567 Door Pressure Limiter Polarity 0 1 Door Pressure Limiter polarity


0 = Normally Open (NO) contact
1 = Normally Closed (NC) contact

568 Door Direction Change Delay 0 100 Interval time between door open and close commandi in 10 ms steps.

569 Car Gate Vacant State 0 1 Automatic car door position when elevator is vacant
0 = door parked open
1 = door closed

571 Door Photocell Supervisions Stops 2 10 Number of stops for photocell uninterrupted monitoring

573 Door Ensured Opening Time 1 40 Ensured door opening time in 0,1 s steps

574 Door Landing Door Lock Monitoring 5 50 Defines monitoring time for landing door lock contact in 0,1 s steps
Time
576 Door Car Door Contact Monitoring 0 1 0 = disabled
1 = enabled

577 Door Landing Door Lock Contact 0 1 0 = disabled


Monitoring 1 = enabled

579 Indian Door Operation 0 1 Indian Door Operation (IDO)


0 = Disable
1 = Enable

3/19
1374567D03 KCECPU parameter list, KMI, KCEPU ARM5 SW release version 15.4.1.8

Min
ID Parameter Name Max Value Description
Value
581 Door Landing Door Type 0 7 Door Type at Landing
0 = automatic landing doors in use
1 = manual door at landing, A side
2 = manual door at landing, B side
3 = manual door at landing, A & B side
4 = manual door at landing, C side
5 = manual door at landing, A & C side
6 = manual door at landing, B & C side
7 = manual door at landing, A & B & C side

585 TTC CTF Door Side Selection 0 3 0 = Open A Side first


1 = Open B Side first
2 = Open C Side first
3 = Open Car call side first

586 LLD Supervision Floor and Side 0 7 0 = Disabled


1 = LLD Supervision Enabled in A
2 = LLD Supervision Enabled in B
3 = LLD Supervision Enabled in A & B
4 = LLD Supervision Enabled in C
5 = LLD Supervision Enabled in A & C
6 = LLD Supervision Enabled in B & C
7 = LLD Supervision Enabled in A, B & C

699 Door Motion Profile 20 200 Door motion profile adjustment in percentage (%).
This affects to normal opening speed, closing speed and acceleration profile
of serial interface door.

740 Timezone Offset 0 72000 Current timezone offset

Index1: absolute offset in seconds from UTC


Index2: direction, 0=after UTC, 1=before UTC

750 Daily IOTSend Delay 0 72000 Delay for daily data transmission to IoT cloud in seconds after midnight

810 No Service Activation 0 3 Enables/Disables noServicePredict and noServiceReact messages to be sent


to KRM/Cloud
0 = noServicePredict and noServiceReact disabled
1 = noServicePredict enabled
2 = noServiceReact enabl
3 = noServicePredict and noServiceReact enabled

854 PRL High Priority Call Type 0 1 Defines High Priority at landing call type
0 = PRL H call
1 = HEL call
855 PRL High Mode Display Type 0 1 Defines PRL H and HEL mode display type in car and at landing
0 = constant
1 = flashing

Note: Flashing is not needed for MES NA

910 Pin Code Entry Button 0 240 Button-bus code of PIN code entry button on MUL
0 = MUL key-menu button
1 - 240 = button identifier

998 Car Call Group Locking Type 0 1 Car calls group locking type
0 = timer
1 = one call

1007 Enable Call Lockings from Option 0 2 Type of calls locked by LOC/LOL inputs typically connected to PIO/OPT
Boards boards in machine room network.
0 = car call lockings
1 = landing call lockings
2 = car and landing call lockings

NOTE: Lock type selection needs to be done only when using LOC/LOL
inputs.

4/19
1374567D03 KCECPU parameter list, KMI, KCEPU ARM5 SW release version 15.4.1.8

Min
ID Parameter Name Max Value Description
Value
1008 Locking Input Type 0 3 Type of locking inputs
0 = Soft lock for car and landing calls
1 = Hard lock for car and landing calls
2 = Hard lock for car calls and soft lock for landing calls
3 = Hard lock for landing calls and soft lock for car calls

Soft lock does NOT cancel registered call when lock activates.
Hard lock DOES cancel registered call when lock activates.

1010 DOB Operation at Car Call Locked 0 2 Door open button (DOB) operation at floor with car call locks
Floor 0 = DOB enabled
1 = DOB enabled when door opened once
2 = DOB disabled when door is closed

1011 Locked Floor Door Closed Torque 0 3 Locked floor door closed torque control
Control 0 = torque releasing allowed
1 = torque releasing not allowed when when car call locked
2 = torque releasing not allowed when when landing call locked
3 = torque releasing not allowed when when car or landing call locked

1013 DOB Operation at Landing Call Locked 0 2 Door open button (DOB) operation at floor with landing call locks
Floor 0 = DOB enabled
1 = DOB enabled when door opened once
2 = DOB disabled when door is closed

1014 Landing Call Lock Indication Type 0 1 Landing call locking indication type at display
0 = lock icon is shown always when floor is locked
1 = lock icon is shown only when call is pressed at locked floor

1017 Landing Lock Operation Group 0 3 Landing call lock operation when group elevator operates as single lift.
Disconnected 0 = Follow IO, Landing call lock status follows locking I/O
1 = Last known, Last known landing call lock status copied from group
2 = All open, All landing call locks are set unlocked
3 = All locked, All landing call locks are set locked

1070 Gong Volume 0 10 Landing/car gong volume at floors other than main floor
0 = off
1 ... 10 = volume level

1071 Gong Volume Main 0 10 Landing/car gong volume at main floor


0 = off
1 ... 10 = volume level

1073 Out of Service Return Floor (OSS) 0 252 Out of service (OSS) return floor.
In use when OSS switch connected to OPT or PIO board.

0 = return to nearest floor


1 ... 250 = specified return floor
251 = return to main floor
252 = return to lowest floor

1074 Out of Service Door Open Side (OSS) 0 7 Out of service (OSS) door opening side
0 = doors closed
1 = A side door open
2 = B side door open
3 = A & B side doors open
4 = C side door open
5 = A & C side doors open
6 = B & C side doors open
7 = A & B & C side doors open

1077 Car Call Preference Time 0 100 Car call preference time in 0,1 s steps

5/19
1374567D03 KCECPU parameter list, KMI, KCEPU ARM5 SW release version 15.4.1.8

Min
ID Parameter Name Max Value Description
Value
1080 Car Call Light Cancel Point 0 2 Car call registering light cancel point
0 = when elevator has stopped at destination floor or door starts to open
1 = when elevator starts to decelerate to destination floor
2 = when elevator has stopped to destination floor and doors are fully
opened or retiring ramp has released

1081 Landing Call Light Cancel Point 0 2 Landing call registering light cancel point
0 = when elevator has stopped at destination floor or door starts to open
1 = when elevator starts to decelerate to destination floor
2 = when elevator has stopped to destination floor and doors are fully
opened or retiring ramp has released

1082 Load Weighing Device Type (LWD) 0 2 Load weighing device type
0 = LWD device with analog output (CCG input)
1 = LWD device with potential free contacts (CCG inputs)
2 = LWD device with potential free contacts (OPT inputs)

1083 Full Load Limit 5 100 Full load limit for car load in percentage (%)

1085 Car Ventilation Type 0 8 Car ventilation (fan) control type


0 = OCV permanently OFF
1 = OCV A (B), automatic
2 = OCV AF (BF) automatic or permanently OFF by switch
3 = OCV K, manual operation, impulse type switch (e.g.button)
4 = OCV I, manual operation, toggle type switch (e.g.button)
5 = OCV M, manual operation
6 = OCV P, car ventilation permanently ON
7 = OCV CV_VI for India
8 = OCV IA, Manual operation, impulse switch, Automatic OFF

1086 Car Ventilation Time 0 360000 Delay to turn car ventilation off after last run in 0.1 s steps

1087 Car Light Type 0 6 Car light control type


0 = OCL permanently OFF
1 = OCL A, auto operation
2 = OCL AF, auto operation or permanently OFF by switch
3 = OCL AT, automatic operation, TEST
4 = OCL I, manual operation, impulse type switch (or button)
5 = OCL M, manual operation
6 = OCL P, permanently ON

1088 Car Light Time 0 360000 Delay to turn car light off after last run in 0.1 s steps

1090 Load Weighing Device error type 0 1 Load weighing device (LWD) error type
0 = Device error disabled, load status follows car load percentage, fault
code activated
1 = Device error enabled, load status forced to overload regardless of actual
load percentage, fault code activated

1092 OSS Landing Configuration Type 0 1 OSS Landing Configuration Type


0 = by switch location
1 = by parameters

1100 Car Light Power 0 100 Car light power consumption limits in percentage of learned current
1st index: warning limit
2nd index: error limit

1102 Automatic Fault Recovery Time 0 300 Timeout for automatic fault recovering in seconds

1103 Battery Supervision Disabled Time 0 22 Car roof battery supervision disabled time in hours (h).
Car roof battery supervision will be disabled for the time given by this
parameter.

1107 Fault Call Cancel Delay 0 240 Delay in seconds to cancel existing calls in system when fault happens.

6/19
1374567D03 KCECPU parameter list, KMI, KCEPU ARM5 SW release version 15.4.1.8

Min
ID Parameter Name Max Value Description
Value
1109 Buzzer Volume 0 10 Buzzer volume at floors other than main floor
0 = off
1 ... 10 = volume level

1110 Buzzer Volume Main 0 10 Buzzer volume at main floor


0 = off
1 ... 10 = volume level

1115 PRC Time 0 300 Timeout in seconds for giving car call during priority call in car (PRC B/T)
mode.

1121 Landing Gong Type 0 1 Landing gong (GOL) type


0 = electronic gong
1 = mechanical gong

1122 Landing Gong Trigger Point 1 8 Landing gong (GOL) trigger point
1 = deceleration
2 = arriving at door zone
3 = stopped
4 = door fully opened
5 = in advance floor
6 = in advance time

1123 Landing Gong for Car Call 0 1 Landing gong (GOL) operation for car call
0 = disabled
1 = enabled

1124 Number of Landing Gong Sounds, 1 3 Landing gong (GOL), number of sounds down
Down
1125 Number of Landing Gong Sounds, Up 1 3 Landing gong (GOL), number of sounds up

1126 Landing Gong Triggering Distance 1 4 Landing gong (GOL) triggering distance in floors

1127 Landing Gong Activation Time in 1 9 Landing gong (GOL) advance activation time in seconds
Advance
1128 Landing Gong Pulse Time 1 20 Mechanical landing gong (GOL) pulse time in 0.1 s steps

1129 Time Between Pulses with Landing 1 20 Landing gong (GOL), time between gong pulses in 0.1 s steps
Gong
1131 Car Gong Type 0 1 Car gong (GOC) type
0 = electronic gong
1 = mechanical gong

1132 Car Gong Trigger Point 1 8 Car gong (GOC) trigger point
1 = deceleration
2 = arriving at door zone
3 = stopped
4 = door fully opened
5 = in advance floor
6 = in advance time

1133 Car gong (GOC) operation for car call 0 1 Car gong (GOC) operation for car call
0 = disabled
1 = enabled

1134 Number of Car Gong Sounds, Down 1 3 Car gong (GOC), number of sounds down

1135 Number Of Car Gong Sounds, Up 1 3 Car gong (GOC), number of sounds up

1136 Car Gong Triggering Distance 1 4 Car gong (GOC) triggering distance in floors

1137 Car Gong Activation Time in Advance 1 9 Car gong (GOC) advance activation time in seconds

1138 Car Gong Pulse Time 1 20 Car gong (GOC) pulse time in 0.1 s steps

1139 Time Between Pulses with Car Gong 1 20 Car gong (GOC), time between gong pulses in 0.1 s steps

7/19
1374567D03 KCECPU parameter list, KMI, KCEPU ARM5 SW release version 15.4.1.8

Min
ID Parameter Name Max Value Description
Value
1141 Lantern (LAL) Operation when Lift 0 1 Lantern (LAL) operation when lift is vacant
Vacant 0 = both off
1 = both on

1142 LAL Operate as HSL 0 1 Lantern operated as HSL


0 = disabled
1 = enabled

1143 LAL Lantern Operation at Main Floor 0 1 Lantern operation at main floor when car is vacant
when Vacant 0 = operation similar to other floors
1 = UP lantern is illuminated

1144 Blinking Lantern at Landing 0 1 Blinking lantern (LAL)


0 = disabled
1 = enabled

1145 LAL Lantern Operation during PRL 0 1 Lantern (LAL) operation during PRL mode
Mode 0 = disabled
1 = enabled

1146 LAL Trigger Point 1 8 Lanterm (LAL) trigger point


1 = deceleration
2 = arriving at door zone
3 = stopped
4 = door fully opened
5 = in advance floor
6 = in advance time

1147 LAL Triggering Distance 1 4 Lantern (LAL) triggering distance in floors

1148 LAL Triggering Time 1 9 Lantern (LAL) advance activation time in seconds

1149 Lanterns ILA Operation 0 4 Lanterm (LAL) operation with ILA allocation
0 = disabled
1 = Constant at allocation - blink at LAL trigger point
2 = Blink at allocation - constant at LAL trigger point
3 = Blink at allocation - blink at LAL trigger point
4 = Constant at allocation - constant at LAL trigger point

1151 Lantern (LAC) Operation when Lift 0 1 Lantern (LAC) operation when lift is vacant
Vacant 0 = both off
1 = both on

1152 LAC Operate as HSL 0 1 Lantern operated as HSL


0 = normal LAC operation
1 = lantern is operating as HSL

1153 LAC Lantern Operation at Main Floor 0 1 Lantern operation at main floor when car is vacant
when Vacant 0 = operation similar to other floors
1 = UP lantern is illuminated

1154 Blinking Lantern in Car 0 1 Blinking lantern (LAC)


0 = disabled
1 = enabled

1155 LAC Lantern Operation during PRL 0 1 Lantern (LAC) operation during PRL mode
Mode 0 = disabled
1 = enabled

1156 LAC Trigger Point 1 8 Lantern (LAC) trigger point


1 = deceleration
2 = arriving at door zone
3 = stopped
4 = door fully opened
5 = in advance floor
6 = in advance time

1157 LAC Triggering Distance 1 4 Lantern (LAC) triggering distance in floors

8/19
1374567D03 KCECPU parameter list, KMI, KCEPU ARM5 SW release version 15.4.1.8

Min
ID Parameter Name Max Value Description
Value
1158 LAC Triggering Time 1 9 Lantern (LAC) advance activation time in seconds

1161 Overload Polarity 0 1 Overload polarity


0 = Normally Open (NO) contact
1 = Normally Closed (NC) contact

1162 Full Load Polarity 0 1 Full load polarity


0 = Normally Open (NO) contact
1 = Normally Closed (NC) contact

1167 ACU Announcement Time Interval 5 120 ACU is triggered for every defined time (seconds)

1168 CPI Triggering Point 0 1 Car position display (CPI) triggering point
0 = advance floor
1 = actual floor

1170 ACU Floor Announcements 0 250 ACU floor announcements


0 = disabled
1 ... 250 = enabled

1172 ACU DCS Feature 0 1 ACU operation in car with DCS


0 = enabled for handicapped calls only
1 = enabled always

1173 ACU Overloaded Announcement 0 1 ACU 'overloaded' announcement


0 = disabled
1 = enabled

1174 ACU Going Up Announcement 0 1 ACU 'going up' announcement


0 = disabled
1 = enabled

1175 ACU Going Down Announcement 0 1 ACU 'going down' announcement


0 = disabled
1 = enabled

1176 ACU Obstruction From Doors 0 1 ACU 'obstruction from doors' announcement
Announcement 0 = disabled
1 = enabled

1177 ACU Required For Emergency 0 1 Enable/Disable ACU


Announcement 'Elevator required for an emergency. Please leave lift when door opens'
announcement
0 = disabled
1 = enabled

1178 ACU Earthquake Announcement 0 1 ACU 'earthquake' announcement


0 = disabled
1 = enabled

1179 ACU Power Failure Announcement 0 1 ACU 'power failure' announcement


0 = disabled
1 = enabled

1180 ACU Fire Alarm Announcement 0 1 ACU 'fire alarm' announcement


0 = disabled
1 = enabled

1181 ACU Doors Closing Announcement 0 1 ACU 'door closing' announcement


0 = disabled
1 = enabled

1182 ACU Doors Opening Announcement 0 1 ACU 'door opening' announcement


0 = disabled
1 = enabled

9/19
1374567D03 KCECPU parameter list, KMI, KCEPU ARM5 SW release version 15.4.1.8

Min
ID Parameter Name Max Value Description
Value
1183 ACU Please Leave Lift Announcement 0 1 ACU 'please leave lift' announcement
0 = disabled
1 = enabled

1184 ACU Transfer Floor Announcement 0 1 ACU 'transfer floor' announcement


0 = disabled
1 = enabled

1185 ACU language 0 50 Language selection for ACU


0=None, 1=Arabic, 2=Chinese, 3=Czech, 4=Danish, 5=Dutch, 6=UK English,
7=Estonian, 8=Finnish, 9=Flemish, 10=French, 11=German, 12=Greek,
13=Hungarian, 14=Italian, 15=Japanese, 16=Korean, 17=Latin, 18=Latvian,
19=Lithuanian, 20=Norwegian, 21=Polish, 22=Portugal, 23=Portuguese,
24=Russian, 25=Slovak, 26=Spanish, 27=Swedish, 28=Turkish, 29=Catalan,
30=Icelandic, 31=Slovenian, 32=Austrian German, 33=Mainland Chinese,
34=NA English, 35=NA French, 36=Univ English, 37=Marine English,
38=Hebrew, 39=Hebrew with AES, 40=Singapore English 1, 41=Singapore
English 2, 42=Australian English 1, 43=Australian English 2, 44=English for
Mandarin, 45 =Serbian, 46=Ukrainian, 47 = Croatian, 48 = Welsh, 49 =
Welsh English, 50 = Irish, 51 = Malay, 52 = NA French, 53 = Indian English
Index1 = First language
Index2 = Second language
...

1186 Display Fields in Car 0 8 Display Fields in Car Display


0 = None
1 = OSI indication
2 = FRD indication
3 = OLF indication
4 = PRC indication
5 = LOC indication
6 = ATS indication
7 = HEL/MES indication
8 = EAQ indication

1187 Display Fields at Landing 0 8 Display Fields on Landing Display


0 = None
1 = OSI indication
2 = PRC indication
3 = FRD indication
4 = HEL/MES indication
5 = ATS indication
6 = BLF indication
7 = LOL indication
8 = EAQ indication

1188 LCD Language Primary 0 39 Primary language selection for LCD displays
0=None, 1=Arabic, 2=Chinese, 3=Czech, 4=Danish, 5=Dutch, 6=UK English,
7=Estonian, 8=Finnish, 9=Flemish, 10=French, 11=German, 12=Greek,
13=Hungarian, 14=Italian, 15=Japanese, 16=Korean, 17=Latin, 18=Latvian,
19=Lithuanian, 20=Norwegian, 21=Polish, 22=Portugal, 23=Portuguese,
24=Russian, 25=Slovak, 26=Spanish, 27=Swedish, 28=Turkish, 29=Catalan,
30=Icelandic, 31=Slovenian, 32=Austrian German, 33=Mainland Chinese,
34=NA English, 35=NA French, 36=Univ English, 37=Marine English,
38=Hebrew, 39=Hebrew with AES

10/19
1374567D03 KCECPU parameter list, KMI, KCEPU ARM5 SW release version 15.4.1.8

Min
ID Parameter Name Max Value Description
Value
1189 LCD Language Secondary 0 39 Secondary language selection for LCD displays
0=None, 1=Arabic, 2=Chinese, 3=Czech, 4=Danish, 5=Dutch, 6=UK English,
7=Estonian, 8=Finnish, 9=Flemish, 10=French, 11=German, 12=Greek,
13=Hungarian, 14=Italian, 15=Japanese, 16=Korean, 17=Latin, 18=Latvian,
19=Lithuanian, 20=Norwegian, 21=Polish, 22=Portugal, 23=Portuguese,
24=Russian, 25=Slovak, 26=Spanish, 27=Swedish, 28=Turkish, 29=Catalan,
30=Icelandic, 31=Slovenian, 32=Austrian German, 33=Mainland Chinese,
34=NA English, 35=NA French, 36=Univ English, 37=Marine English,
38=Hebrew, 39=Hebrew with AES

1191 Parking Floor (PAD) 0 250 PAD floor


0 = parking to main floor
1 ... 250 = parking floor

1192 Parking Door (PAD) 0 7 Door operation at parking floor


0 = doors closed
1 = A side door open
2 = B side door open
3 = A & B side doors open
4 = C side door open
5 = A & C side doors open
6 = B & C side doors open
7 = A & B & C doors open

1193 Parking Delay (PAD) 5 300 Timeout for parking in seconds

1194 Basic SPI in Car 0 1 SPI message type for car displays
0 = extended SPI
1 = basic SPI (old old graphical displays e.g. DELEL and EP1)

1195 Basic SPI at landing 0 1 SPI message type for landing displays
0 = extended SPI
1 = basic SPI (old old graphical displays e.g. DELEL and EP1)

1197 FCC Number of Allowed Stops 1 10 Number of consecutive stops without photocell cuts to cancel car calls

1203 Start Supervision Timeout 1 120 Start supervision timeout in 0,1 s steps.

1205 Stop Delay 0 100 Stop delay in 0,1 s steps between two consecutive starts.

1206 Stop Delay for Relevelling 0 100 Stop delay for relevelling in 0,1 s steps

1207 Final Stopping Point 0 126 Final stopping point


Distance in 1 mm steps from accurate floor level, normal run

1209 V3F Stop Delay Normal Drive 10 200 Time interval in 10 ms steps from speed level signal to stop signal at
stopping phase.

1210 V3F Stop Delay At Inspection Drive 10 200 Time interval in 10 ms steps from speed signal to stop signal at stopping
phase.

1211 V3F Stop Delay for Releveling 10 200 Time interval in 10 ms steps from speed signal to stop signal at stopping
phase.

1212 V3F Stop Delay for EBD Drive 10 200 Time interval in 10 ms steps from speed signal to stop signal at stopping
phase.

1216 Maximum Drive Time for Releveling 10 200 Maximum drive time in 0,1 s steps for releveling.
(ACL)
1217 Final Releveling Stopping Point (ACL) 0 126 Defines distance in 1 mm steps from accurate floor level.

1221 Short Floor Length 200 3000 Maximum length for short floor in millimeters

1231 Star Time for Hydro 0 20 Star time in 0,1 s steps for DOL or Star/Delta pump start sequence with a
hydraulic elevator.
0 = Direct (DOL) start
1 ... 20 = Star ON time before Delta

11/19
1374567D03 KCECPU parameter list, KMI, KCEPU ARM5 SW release version 15.4.1.8

Min
ID Parameter Name Max Value Description
Value
1232 Pump Off Delay for Hydro 0 50 Delay in 0,1 s steps to keep pump on after up valve is switched off

1234 Delay After Delta 1 50 Delay in 0,1 s steps between delta on and control signals.

1235 Final Stopping Point Up for Hydro 0 126 Final stopping point for up direction, hydraulic elevator
Distance in 1 mm steps from accurate floor level

1236 Final Stopping Point Down for Hydro 0 126 Final stopping point for down direction, hydraulic elevator
Distance in 1 mm steps from accurate floor level

1237 Pilot Valve Delay 1 30 Delay in 0,1 s steps for Hydronic 200 pilot valve.
Used only if direct (DOL) start in use.

1239 Anti Creep Zone Upper Limit 0 50 Upper limit for anti creep device releasing.
Distance in 1 mm steps from accurate floor level.

1240 Anticreep Device Contact Polarity 0 1 Polarity of anti creep device contact.
0 = Normally Open (NO) contact
1 = Normally Closed (NC) contact

1298 Deceleration Point Offset 0 75 The point on which the elevator starts to decelerate on deceleration
magnet.
Offset in 1 mm steps from the middle of the magnet.

1299 Relevelling (ACL) Distance 2 40 Distance in 1 mm steps from door zone's zero middle point

1302 EMO Indication in Car 0 1 EMO indication in car


0 = light
1 = light and buzzer

1303 MRT Return Floor 0 250 Machine room temperature (MRT) return floor
0 = stops to destination floor, stays at current floor
1 ... 250 = specified return floor

1306 LIL Type 0 3 Elevator link (LIL) feature


0 = LIL AB/C, alarm devices + binary coded and analog car position
1 = LIL AMB/C, alarm devices + mode signals + binary coded and analog car
position
2 = LIL ASB/C, alarm devices + status signals + binary coded and analog car
position
3 = LIL AMB/C + ASB/C (all) signals enabled

1309 EAQ Memory 0 1 Memory for EAQ counterweight derailment and seismic detection
0 = disabled
1 = enabled (reset required)

1310 EAQ Seismic Operation 0 1 Operation for EAQ seismic detection


0 = Elevator stops to nearest possible floor with reduced speed
1 = Elevator emergency stops and makes a correction drive to nearest
possible floor

1314 FRE Door Side 0 7 Door opening side at fast recall service (FRE) return floor
0 = disabled
1 = A side door open
2 = B side door open
3 = A & B side doors open
4 = C side door open
5 = A & C side doors open
6 = B & C side doors open
7 = A & B & C side doors open

1316 Water Sensor Contact Return Floor 0 250 Water sensor contact (WSC) return floor
(WSC) 0 = nearest floor
1 ... 250 = specified return floor

12/19
1374567D03 KCECPU parameter list, KMI, KCEPU ARM5 SW release version 15.4.1.8

Min
ID Parameter Name Max Value Description
Value
1317 Water Sensor Contact Indication 0 2 Additional indications for WSC mode
(WSC) 0 = disabled
1 = returned indication
2 = returned indication with returning buzzer

1319 ECO Mode Timeout 600 12000 Timeout in 0,1 s steps for stand by mode after last run.

1323 SDO Type 0 1 Standing Doors Open (SDO) type


0 = all floors
1 = main floor

1344 Stopping Inaccurate Limit 1 7 Number of allowed inaccurate stops for monitoring.

1345 Stopping Accuracy Monitoring Count 1 32 Number of consecutive accurate stops.

1346 Stopping Accuracy Monitoring 5 50 Stopping accuracy monitoring distance for a stop in 1 mm steps.
Distance
1347 Stopping Accuracy Monitoring Time 1 100 Accuracy stopping monitoring time in 10 ms steps after main contactor de-
energizing.

1349 Out of Door Zone Monitoring Time 1 300 Defines time in seconds to trigger fault code for elevator stopped between
floor levels.

1351 FCC R Time 0 50 Timeout in 0,1 s for car call cancelling with second push FCC R.

1352 Door Close Command Keep Active 1 10 Timeout in seconds to keep door close command activated for SSA or PIT
Time INSPECTION reset.

1353 Door Contacts Bypassed Indication 0 3 Door contact bypassing indication type
Type 0 = Constant light, buzzer turned on when contact is bypassed and lift is
moving
1 = Flashing light, buzzer turned on when contact is bypassed and lift is
moving
2 = Constant light, buzzer turned on when contact is bypassed
3 = Flashing light, buzzer turned on when contact is bypassed

1355 Empty Car Detection Type 0 2 0 = nominal load parameter


1 = sensor
2 = both nominal load and sensor

1356 Car Call Unlocking Timer for PVS 5 120 Timeout in seconds for keeping car call unlocked during Penthouse Visitor
mode

1357 Empty Car Load Limit 0 50 Defines limit in percentages for empty car load detection.

1359 By Pass Indication (BPI) Type 0 1 Bypass indication at landing type


0 = indication at bypassed floor
1 = indication at all floors when bypassing

1361 Landing Call Light Blinking Type 0 1 Landing call light blinking type
0 = blinking when elevator is moving
1 = blinking always

1362 Landing Call Blinking Frequence 2 20 Interval time in 0,1 s for landing call light blinking

1363 EBD Shut Down Timeout 3 120 Specific shut down timeout in seconds after EBD return. Timeout starts
when door is fully opened.

1364 EBD Door Operation 0 1 Door operation in EBD mode


0 = door closes after EBD/FID door open time
1 = door remains open

1366 RBO fault type 0 1 Rescue Brake Opening (RBO) fault type
0 = warning, elevator stays in service
1 = fatal, elevator stays out of service

13/19
1374567D03 KCECPU parameter list, KMI, KCEPU ARM5 SW release version 15.4.1.8

Min
ID Parameter Name Max Value Description
Value
1367 RBO Device Floor 0 250 Rescue Brake Opening (RBO) device floor
0 = highest floor
1 ... 250 = RBO device floor

1368 RBO Device Side 0 3 Defines RBO device side at TTC floor
1 = A side
2 = B side
3 = C side

1369 Time for Bypass Indication 5 50 Time in 0,1 s steps for bypass indication at landing.

1370 Belt Monitoring Delay 1 60 Delay in seconds to trigger belt tensioning when elevator is vacant.

1371 Belt Monitoring Floor 0 248 Belt tensioning floor, 1 ... 250.

1372 Belt Monitoring Time 1 250 Time in seconds for belt tensioning.

1373 Belt Tensioning Interval Time 5 1440 Defines time interval in minutes for belt tensioning.

1377 ATS Buzzer 0 1 Attendant service (ATS) buzzer


0 = disabled
1 = enabled

1378 RES Speed 0 25 Defines lower speed in 0,1 m/s steps to be used during special elevator
features
0 = nominal speed in use
1 ... 20 = speed in m/s

1384 Power Up Delay Time 0 900 Power Up delay time in seconds

1386 EAQ Primary Wave Timer, EN81 77 1 300 Primary wave detection timer in seconds, EN 81-77:2013.

1387 EAQ Seismic Detection Test Time, 2 1440 Seismic detection test interval time in minutes, EN 81-77:2013.
EN81 77
1389 Hydro Oil Temperature Recovery Time 0 600 Timeout in seconds for automatic recovery from oil temperature fault

1391 EPD Return Floor 0 250 Return floor for Emergency Power Drive (EPD).
0 = return drive to nearest floor
1...250 = return floor number

1392 EPD Door Open Side 0 7 Door opening side at Emergency Power Drive (EPD) return floor
0 = doors closed
1 = A side door open
2 = B side door open
3 = A & B side doors open
4 = C side door open
5 = A & C side doors open
6 = B & C side doors open
7 = A & B & C side doors open

1393 EPD Car Light and Fan Operation 0 1 Car light and car fan operation after EPD return drive.
0 = OFF immediately
1 = OFF after timeout defined by parameter

1394 Car Light Control during Service 0 2 Car light control during service drive modes
Modes 0 = car light permanently OFF
1 = car light permanently ON
2 = car light OFF after car light delay when elevator is stopped

1395 Car Ventilation Control during Service 0 2 Car ventilation control during service drive modes
Modes 0 = car ventilation permanently OFF
1 = car lventilation permanently ON
2 = car ventilation OFF after car ventilation delay when elevator is stopped

14/19
1374567D03 KCECPU parameter list, KMI, KCEPU ARM5 SW release version 15.4.1.8

Min
ID Parameter Name Max Value Description
Value
1396 Emergency Power (EPD) Speed 0 20 Defines driving speed in 0,1 m/s steps used under emergency power (EPD)
0 = nominal speed in use
1 ... 20 = speed in m/s

1398 Well Access Protection Timeout 10 120 Timeout for well access protection mode in seconds

1399 Car Height 2000 4000 Car height in millimeters.

1405 FID Return Floor Main 0 250 Main return floor level for Fire Detection (FID).
0 = return drive to nearest floor
1 ... 250 = return floor number

1406 FID Return Floor Alternative 0 250 Alternative return floor level for Fire Detection (FID).
0 = return drive to nearest floor
1 ... 250 = return floor number

1408 FID Door Open Side Main 0 10 Door opening side at main fire detection return floor (FID B/S)
0 = doors closed, at TTC floor all door opens and stay closed
1 = A side door parked open
2 = B side door parked open
3 = A & B side doors parked open
4 = C side door parked open
5 = A & C side doors parked open
6 = B & C side doors parked open
7 = A & B & C side doors parked open
8 = At TTC floor A-side door opens and stays closed
9 = At TTC floor B-side door opens and stays closed
10 = At TTC floor C-side door opens and stays closed

1409 FID Door Open Side Alternative 0 10 Door opening side at alternative fire detection return floor (FID A)
0 = doors closed, at TTC floor all door opens and stay closed
1 = A side door parked open
2 = B side door parked open
3 = A & B side doors parked open
4 = C side door parked open
5 = A & C side doors parked open
6 = B & C side doors parked open
7 = A & B & C side doors parked open
8 = At TTC floor A-side door opens and stays closed
9 = At TTC floor B-side door opens and stays closed
10 = At TTC floor C-side door opens and stays closed

1410 FID_M Door Opening Side 0 10 Door opening side at floor for machine room fire detection (FID M)
0 = doors closed, at TTC floor all door opens and stay closed
1 = A side door parked open
2 = B side door parked open
3 = A & B side doors parked open
4 = C side door parked open
5 = A & C side doors parked open
6 = B & C side doors parked open
7 = A & B & C side doors parked open
8 = At TTC floor A-side door opens and stays closed
9 = At TTC floor B-side door opens and stays closed
10 = At TTC floor C-side door opens and stays closed

1415 FID Car Light and Fan Operation 0 1 Car light and car fan operation after fire detection return drive.
0 = OFF immediately
1 = OFF after timeout defined by parameter

1421 FRD Return Floor 1 250 Fire service access floor level for firefighters to gain access to the fireman's
lift.
1 ... 250 = Fireman's return floor number

15/19
1374567D03 KCECPU parameter list, KMI, KCEPU ARM5 SW release version 15.4.1.8

Min
ID Parameter Name Max Value Description
Value
1422 FRD Return Floor Side 1 7 Door opening side at fire service access level for firefighters to gain access
to the fireman's lift.
1 = A side
2 = B side
3 = A & B side
4 = C side
5 = A & C side
6 = B & C side
7 = A & B & C side

1435 FRD Return Floor Alternative 1 250 Fire service alternative access floor level for firefighters to gain access to
the fireman's lift.
1 ... 250 = Fireman's return floor number

1436 FRD Return Floor Side Alternative 1 7 Door opening side at fire service alternative access level for firefighters to
gain access to the fireman's lift.
1 = A side
2 = B side
3 = A & B side
4 = C side
5 = A & C side
6 = B & C side
7 = A & B & C side

1437 FRD Return Floor Door Operation 0 1 Door operation at fire service alternative access level for firefighters to gain
Alternative access to the fireman's lift.
0 = hold open
1 = closed after predefined time

1444 FRD Override Mode Timeout 0 180 Timeout in seconds for overriding existing mode by FRD.
0 = no automatic override when door open
1 ... max = Force door closing by FRD after this timeout

Index1 (ATS)
Index2 (PRC)

1446 FRD Car Call Registering during 0 1 Defines car call registering while decelerating
Deceleration 0 = disabled
1 = enabled

1447 FRD_EVA_Elevator_Type 0 2 Defines whether elevator shall be used as fire lift, EVA lift or secondary EVA
lift.
0 = fire lift
1 = EVA lift
2 = Secondary EVA lift

1448 Shandong Indication 0 1 Defines Shandong indication (FDI) during firemans drive
0 = disabled
1 = enabled

1451 AES Stop Floors 0 3 0 = not allowed


1 = down
2 = up
3 = down & up

1452 AES Door Time at Main Floor 10 240 AES door open time in seconds at main floor

1453 AES Door Time at Other Floors 10 240 AES door open time in seconds at other floors

1454 AES Calls 0 3 0 = car and landing calls disabled


1 = car calls enabled and landing calls disabled
2 = car calls disabled and landing calls enabled
3 = car and landing calls enabled

16/19
1374567D03 KCECPU parameter list, KMI, KCEPU ARM5 SW release version 15.4.1.8

Min
ID Parameter Name Max Value Description
Value
1455 AES Floor 0 3 0 = Main floor
1 = Floor where lift stops after serving existing calls
2 = Main floor with AES stop floors served
3 = Floor where lift stops after serving existing calls with AES stop floors
served

1456 AES Car Call Lights 0 2 0 = Normal car call button lights
1 = Illuminate all car call button lights
2 = Illuminate car call button lights as per AES stop floors

1457 AES Display 0 3 0 = No AES display


1 = AES display in car
2 = AES display at landing
3 = AES display in car and at landing

1458 AES Buzzer 0 1 0 = disabled


1 = enabled

1460 AES Clock Switch 0 3 0 = not in use


1 = in use and elevator will be in normal mode
2 = in use and elevator goes to standby mode with doors closed
3 = in use and elevator goes to standby mode with doors open

1461 AES Landing Indication Type 0 1 0 = Out of Service Indication


1 = AES indication

1464 Lock Single Lift Operation Car Calls 0 1 Car call lock from group/E-link operation when group disconnects.
0 = Last received car call lock status
1 = All open, All car call locks are set unlocked

1465 ACU volume 0 10 Announcement (ACU) volume adjustment


0 = OFF
1 ... 10 = volume level

1467 Rescue Mode and Announcer Feature 0 5 Rescue mode indication


0 - No indication
1 - Audio indication buzzer in use
2 - Audio indication Announcer in use
3 - Visual indication in use
4 - Audio buzzer & Visual indication in use
5 - Audio announcer & Visual indication in use

Index 1 – RMI - Audio buzzer/ announcer/ backlight indicator


Index 2 – DMI display in car during rescue mode -> 0 – OSI indication, value
greater than zero – Rescue mode indication (India specific)

1468 Fill level sensor 0 1 0 = Disabled


1 = Enabled

1476 Goods Detection Door Open time 60 3600 Goods Detection Door Open time

1477 Goods Detection Door control 0 1 Goods Detection Door control


0 = Do not keep door open(normal operation)
1 = Keep door open

1479 KCEMSC Periodical Test Time In Hours 0 23 KCEMSC Periodical Test Window Open In Hours

1481 ADF Dispatch Floor 1 250 Automatic Dispatch Floor (ADF)


1 ... 250 = floor number for automatic dispatch

1482 ADF Destination Floor 0 250 Automatic Destination Floor (ADF)


0 == main floor
1 ... 250 = destination floor for elevator dispacthing

17/19
1374567D03 KCECPU parameter list, KMI, KCEPU ARM5 SW release version 15.4.1.8

Min
ID Parameter Name Max Value Description
Value
1483 Lantern Control at Terminal Floors 0 3 Lantern control at terminal floor
0 = similar to intermediate floor (default)
1 = both arrows controlled up at lowest floor
2 = both arrows controlled down at highest floor
3 = both arrows controlled up at lowest floor and down at highest floor

1484 ACU Required for Evacuation 0 1 Elevator Required for Evacuation. Please Leave Lift When Door Opens
Announcement Announcement
0 = disabled
1 = enabled

1485 KCEPIO Rate Limit 1 50 Filtering time to send input state updates from node in 10 ms steps.

1486 Silent Night Feature (SNF) Start Time 0 23 Silent Night Feature (SNF) Start Time In Hours
In Hours
1487 Silent Night Feature (SNF) End Time In 0 23 Silent Night Feature (SNF) End Time In Hours
Hours
1488 Reduced Speed Feature (RES) Start 0 23 Reduced Speed Feature (RES) Start Time In Hours
Time In Hours
1489 Reduced Speed Feature (RES) End 0 23 Reduced Speed Feature (RES) End Time In Hours
Time In Hours
1490 Battery Stress Test Interval Time 72 8760 Car roof emergency battery stress test interval time in hours (h).

1491 Battery Stress Test Fault Type 0 1 Car roof emergency battery stress test fault type
0 = warning, elevator stays in service
1 = fatal, elevator stays out of service

1492 Battery Stress Test Duration 1 600 Defines duration time in minutes for emergency battery stress test.

1493 Battery Stress Test Fault Level 105 125 Defines voltage level for emergency battery stress test.
Value is voltage x 10.

1494 EBD Return Floor 0 250 EBD Return Floor


0 = Nearest Floor
1...250 = Return Floor Number

1495 EBD Door Open Side 1 7 Door Opening Side At EBD Return Floor
1 = A side door
2 = B side door
3 = A & B side doors
4 = C side door
5 = A & C side doors
6 = B & C side doors
7 = A & B & C side doors

1497 ERD Battery Supervision Time 5 23 ERD Battery Supervision Time in Hours (5…23 hours)

1498 Supplementary Battery System 0 1 Supplementary Battery System (SBS) Supervision


(SBS) Supervision 0 = Disabled
1 = Enabled
1499 Car Battery Supervision Type 0 1 Defines fault action to be taken when fault 1611 is thrown.
0 = cancel only landing calls
1 = cancel both car calls and landing calls , Additional trigger for CBS based
on ATS switch state change(recommended for India). Additional manual
trigger is not applicable to SBS

1505 RAD Speed 0 1 Defines lower speed in 0,1 m/s steps to be used during RAD (UltraRope
Derailment) Fault activation
0 = nominal speed in use
1 ... 25 = speed in m/s
1507 UCMP Brake Test type 0 1 UCMP Brake Test type
0 = Brake test when lift is idle (only for testing)
1 = Self Monitoring 24 hr brake test

1508 UCMP Brake Test Supervision start 0 23 UCMP Brake Test Supervision start time in hours
time This set time is utilized to calculate beginning, end and 23rd hour of the day
0.

18/19
1374567D03 KCECPU parameter list, KMI, KCEPU ARM5 SW release version 15.4.1.8

Min
ID Parameter Name Max Value Description
Value
1509 Number of Brake Tests 2 6 Number of Brake Tests
Values to be set in the multiple of 2. For example, 2,4 and 6.