1 Safety Precautions Dismantling and Scrapping 4 Grounding 6 External and Cut-out Dimensions
– The MS Series HMI or parts thereof shall be recycled according to local regulations.
Both the installer, the owner, and the operator of this MS Series HMI must read and understand this instal- Make sure that the MS Series HMI works properly. To prevent it from radiating radio frequency noise, the
lation manual. – The following components contain substances that might be hazardous to health and the environment: MS Series HMI must be connected to earth ground.
lithium battery, electrolytic capacitor and display..
General – Without grounding, the MS Series HMI may be severely affected by excess noise. Make sure that the
– Only qualified personnel may install or operate the MS Series HMI. Note: grounding is done properly from the power connector at the rear side of the MS Series HMI. When
Indicated loss of life, severe personal injury, or substantial property damage power is connected, make sure that the wire is grounded.
– The MS Series HMI must be installed according to the installation instructions. ! will result if proper precautions are not taken.
– Use a cable of at least 2 mm2 (AWG 14) to ground the MS Series HMI. Ground resistance must be less
– The MS Series HMI is designed for stationary installation on a plane surface, where the following con-
ditions are fulfilled: than 100 Ohms (class3). Note that the ground cable must not be connected to the same ground point as
the power circuit.
• no high explosive risks
• no strong magnetic fields 2 Package Contents
• no direct sunlight 5 Power Supply and Wiring
• no large, sudden temperature changes
The MS Series HMI must use a power supply with 24 V DC and the power consumption is 20W.
• for use in Pollution Degree 2 Environment
• for use on the flat surface of a Type 1 enclosure Warning:
– Never allow fluids, metal filings or wiring debris to enter any openings in the MS Series HMI. This To avoid an electric shock, be sure to switch off the power before connecting the communica-
may cause fire or electrical shock. tion/download cable to the MS Series HMI.
– The MS Series HMI fulfills the requirements of article 4 of EMC directive 2004/108/EC.
– Storing the MS Series HMI where the temperature is lower/higher than recommended in this manual Steps to wire
can cause the LCD display liquid to congeal/become isotopic. 1. Unplug the power connector and unscrew the screws.
– The LCD display liquid contains a powerful irritant. In case of skin contact, wash immediately with MS-6 0
2. Strip about 7-8mm of insulation. Insert the wire all the way into the power connector and then turn
plenty of water. In case of eye contact, hold the eye open, flush with plenty of water and get medical the screws tight.
attention.
– The supplier is not responsible for modified, altered or reconstructed equipment. 3. Plug in the connector to the power input of the MS Series HMI.
– Use only parts and accessories manufactured according to specifications of the supplier. Note:
– Peripheral equipment must be appropriate for the application and location. Power connector is already plugged in the power input of the MS Series HMI when the package MS-6 0
– The figures in this manual serves an illustrative purpose. Because of the many variables associated with 3 Mounting Procedure is first opened.
any particular installation, the supplier cannot assume responsibility for actual use based on the figures. 1. Cut out the control front panel to match the dimensions (mm) specified under the External and Cut-
– The supplier neither guarantees that the MS Series HMI is suitable for your particular application, nor out dimensions chapter.
assumes responsibility for your product design, installation or operation.
2. Mount the MS Series HMI into the cut-out. Insert the fixtures to the holes on the unit and fasten the
Power Source screws into the front panel. Do not tighten the screws with too much or uneven force, or it may cause
– The MS Series HMI is equipped with a 24 V DC input. Supply power other than 24 V DC ± 15% will deformation of the MS Series HMI.
severely damage the MS Series HMI. Thus, check the power supply supporting the DC power regular-
ly. Step 1 Step 2 Step 3
– To avoid electric shock, be sure the power cable is unplugged from the power input when connecting
the cable to the MS Series HMI.
Installation
-
+
– Communication cables must be separated from the power cables for operational circuits. Use shielded FG
cables or it may cause unpredictable problems. 90º
DC 24V
During Use 135º
135º
y
– Emergency stop and other safety functions may not be controlled from the MS Series HMI. Use Copper Conductors Only, 60/75
la
sp
Di
– Do not use force or sharp objects when touching the keys, display etc.
Service and Maintenance
Wire Gauge
– Only qualified personnel should carry out repairs. Max torque: 0.6~0.7 Nm (5.31~6.2 lb-in) Type Stripped Length Torque
(AWG)
– Before carrying out any cleaning or maintenance operations, disconnect the equipment from the elec- 0º
trical supply. Display Solid 28-12 7-8 mm 4.5 lb-in
– Clean the display and surrounding front cover with a soft cloth and mild detergent. Stranded 30-12 7-8 mm 4.5 lb-in
– Replacing the battery incorrectly may result in explosion. Use batteries recommended by the supplier. 3. The MS Series HMI must be installed within an angle of 0° to 135° as shown above.
Input Power 24 V DC +-15%, less than 20W 1 RS485+ 1 N/A OFF No password is required to start the MS Series HMI
Note:
When using the MS Series HMI for the first time, remember to reset Real Time Clock (RTC).