0% found this document useful (0 votes)
13 views27 pages

Alim 3

The MEAN WELL RSP-750 Series is a 750W single output AC/DC power supply designed for various industrial applications, featuring high efficiency (up to 92%), built-in active PFC, and multiple protection mechanisms. It supports universal AC input and offers programmable output voltage and constant current levels, along with remote ON-OFF control. The power supply is compact, with dimensions of 250x127x41mm, and comes with a 5-year warranty.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
13 views27 pages

Alim 3

The MEAN WELL RSP-750 Series is a 750W single output AC/DC power supply designed for various industrial applications, featuring high efficiency (up to 92%), built-in active PFC, and multiple protection mechanisms. It supports universal AC input and offers programmable output voltage and constant current levels, along with remote ON-OFF control. The power supply is compact, with dimensions of 250x127x41mm, and comes with a 5-year warranty.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 27

Home » MEAN WELL » MEAN WELL RSP-750 Series 750W Power

Supply with Single Output Owner’s Manual

Advertisements

Contents
1 MEAN WELL RSP-750 Series 750W Power Supply with Single Output
2 Features
3 Dimension
4 Applications
5 Description
6 SPECIFICATION
7 Block Diagram
8 Static Characteristics
9 Function Manual
10 Mechanical Specification
11 Documents / Resources
11.1 References
12 Related Posts
MEAN WELL RSP-750 Series 750W Power Supply with Single Output

Features

Universal AC input / Full range


Built-in active PFC function

Advertisements
··· Ezoic
High efficiency up to 92%
Forced air cooling by built-in DC fan
Output voltage and constant current level programmable
Built-in remote ON-OFF control/ remote sense auxiliary power/ DC OK
signal
Protections: Short circuit/Overload/Over voltage/Over temperature
Optional conformal coating

Advertisements

···
Ezoic

5 years warranty

Dimension

Applications

Factory control or automation apparatus


Test and measurement instrument
Laser related machine
Burn-in facility
RF application

GTIN CODE

Advertisements

···

Ezoic

MW Search: https://www.meanwell.comiserviceGTIN.aspx

Description

RSP-750 is a 750W single output enclosed type AC/DC power supply. This
series operates for 90-264 VAC nput voltage and offers the models with
the DC output mostly demanded from the industry. Each model is cooled
by the built-in fan with fan speed control, working for the temperature
up to 70C. Moreover, RSP-750 provides vast design flexibility by
equipping various built-in functions such as the output programming,
remote ON-OFF control, auxiliary power, etc.

Advertisements
···

Ezoic
Model Encoding/ Order Information
SPECIFICATION

RSP RSP RSP RSP RSP


RSP
-75 -75 -75 -75 -75
MODEL -75
0-1 0-1 0-2 0-2 0-4
0-5
2 5 4 7 8

DC VOLTAGE 5V 12V 15V 24V 27V 48V

100 62.5 31.3 27.8 15.7


RATED CURRENT 50A
A A A A A

0~ 0~ 0~ 0~ 0~
0~
CURRENT RANGE 100 62.5 31.3 27.8 15.7
50A
A A A A A

500 750 750 751. 750. 753.


RATED POWER
W W W 2W 6W 6W

150 150 150 150 150 150


RIPPLE & NOISE (max.) Not
mV mV mV mV mV mV
e.2
p-p p-p p-p p-p p-p p-p

4.75 10 13.5 20 24 43
VOLTAGE ADJ. RANGE ~ 5. ~1 ~1 ~2 ~3 ~5
5V 3.5V 6.5V 6.4V 0V 5V

VOLTAGE TOLERANCE Not ±2. ±1. ±1. ±1. ±1. ±1.


O
e.3 0% 0% 0% 0% 0% 0%
UT
PU ±0. ±0. ±0. ±0. ±0. ±0.
T LINE REGULATION
5% 5% 5% 5% 5% 5%

±2. ±0. ±0. ±0. ±0. ±0.


LOAD REGULATION
0% 5% 5% 5% 5% 5%

SETUP, RISE TIME 1000ms, 50ms at full load

16ms/230VAC 16ms/115VAC at f
HOLD UP TIME (Typ.)
ull load

VOLTAGE RANG
E 90 ~ 264VAC 127 ~ 370VDC
Note.4
FREQUENCY RANGE 47 ~ 63Hz

0.97/230VAC 0.98/115VAC at full


POWER FACTOR (Typ.)
IN load
PU
90. 90.
T EFFICIENCY (Typ.) 82% 87% 89% 92%
5% 5%

5V : 5.6A/115VAC 2.8A/230VA
AC CURRENT (Typ.) C 12V~48V : 8.2A/115VAC
3.9A/230VAC

INRUSH CURRENT (Typ.) 25A/115VAC 40A/230VAC

LEAKAGE CURRENT <2.0mA / 240VAC

105 ~ 125% rated output power

Protection type : Constant current limiti


OVERLOAD
ng, recovers automatically after fault c
ondition is removed

5.75 13.8 17 27.6 31 56.6


PR ~ 6. ~1 ~2 ~3 ~3 ~6
OT 75V 6.8V 0.5V 2.4V 6.5V 6.2V
EC OVER VOLTAGE (OVP)
TI Protection type : Shut down o/p voltag
O e, re-power on to recover
N
Shut down o/p voltage, recovers autom
OVER TEMPERATURE
atically after temperature goes down

Adjustment of output voltage is allowa


OUTPUT VOLTAGE PROGR ble to 40 ~ 110% of nominal output volt
AMMABLE(PV) age. Please refer to the Function Manu
al.

Adjustment of constant current level is


FU CONSTANT CURRENT LEVE
allowable to 40 ~ 110% of rated curren
N L PROGRAMMABLE(PC)
t. Please refer to the Function Manual.
CT
IO AUXILIARY POWER 12V @ 0.1A ; tolerance : ±10%
N
Power on : short between Remote ON-O
REMOTE ON-OFF CONTRO FF(pin13) & 12V-AUX(pin14) on CN50 P
L ower off : open between Remote ON-OF
F(pin13) & 12-AUX(pin14) on CN50

The TTL signal out, power supply turn o


DC OK SIGNAL n = 0 ~ 1V ; power supply turn off = 3.3
~ 5.6V

WORKING TEMP. -30 ~ +70℃ (Refer to “Derating Curve”)

WORKING HUMIDITY 20 ~ 90% RH non-condensing

EN STORAGE TEMP., HUMIDIT -40 ~ +85℃, 10 ~ 95% RH non-condens


VI Y ing
R
O
N TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
M
EN 10 ~ 500Hz, 2G 10min./1cycle, 60min.
T VIBRATION
each along X, Y, Z axes

UL62368-1, CSA C22.2 No. 62368-1, TU


V BS EN/EN62368-1, CCC GB4943.1, B
SAFETY STANDARDS
SMI CNS14336-1, AS/NZS62368.1, EA
C TP TC 004 approved

I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:


WITHSTAND VOLTAGE
0.5KVAC

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 5


ISOLATION RESISTANCE
00VDC / 25℃/ 70% RH

Test Level
Parameter Standard
/ Note

BS EN/EN5
Conducted 5032 (CISP Class B
R32)
EMC EMISSION
Radiated BS EN/EN5 Class B
5032 (CISP
SA R32)
FE
TY Harmonic BS EN/EN6
—–
& Current 1000-3-2
E
Voltage Fli BS EN/EN6
M —–
cker 1000-3-3
C

(N BS EN/EN55035, BS EN/EN61000-6-2,
ot CCC GB17625.1,GB/T9254, BSMI CNS1
e 3438
7)
Test Level
Parameter Standard
/ Note

Level 3, 8K
BS EN/EN6 V air ; Level
ESD
1000-4-2 2, 4KV cont
act
EMC IMMUNITY
BS EN/EN6
Radiated Level 3
1000-4-3

BS EN/EN6
EFT / Burst Level 3
1000-4-4

Level 4, 4K
V/Line-Eart
BS EN/EN6
Surge h ; Level 3,
1000-4-5
2KV/Line-L
ine

BS EN/EN6
Conducted Level 3
1000-4-6

Magnetic F BS EN/EN6
Level 4
ield 1000-4-8

Voltage Dip BS EN/EN6 >95% dip 0.


s and Interr 1000-4-11 5 periods,
uptions 30% dip 25
periods,

>95% interr
uptions 25
0 periods

1036.8K hrs min. Telcordia SR-332


MTBF (Bellcore) ; 109.2K hrs min. MIL-HD
OT BK-217F (25℃)
HE
DIMENSION 250*127*41mm (L*W*H)
RS
PACKING 1.64Kg; 6pcs/10.8Kg/1.1CUFT

N 1. All parameters NOT specially mentioned are measured at 230VAC i


OT nput, rated load and 25℃ of ambient temperature.
E
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″
twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regul


ation.

4. Derating may be needed under low input voltages. Please check th


e derating curve for more details.

5. There is high possibility to trigger the floating over voltage protecti


on when PV voltage is trimmed from a high voltage level to a lower vol
tage level at light load or no load condition. It is suggested that turn
off the power supply and set PV voltage to the lowest level, then adjus
t output voltage to a desired value.

6. Strongly recommended that external output capacitance should no


t exceed 5000uF. (Only for: RSP-750-5)

7. The power supply is considered a component which will be installe


d into a final equipment. All the EMC tests are been executed by moun
ting the unit on a 720mm*360mm metal plate with 1mm of thickne
ss. The final equipment must be re-confirmed that it still meets EMC d
irectives. For guidance on how to perform these EMC tests, please ref
er to “EMI testing of component power supplies.” (as available on htt
p://www.meanwell.com)

8. The ambient temperature derating of 3.5℃/1000m with fanless mo


dels and of 5℃/1000m with fan models for operating altitude higher t
han 2000m(6500ft).

※ Product Liability Disclaimer For detailed information, please refer t
o https://www.meanwell.com/serviceDisclaimer.aspx
Block Diagram

Static Characteristics

MODEL
5V 12V 15V
INPUT

500W 750W 750W

100~264VAC 100A 62.5A 50A

450W 675W 675W

90VAC 90A 56.25A 45A

MODEL
24V 27V 48V
INPUT

751.2W 750.6W 753.6W

100~264VAC 31.3A 27.8A 15.7A

676.08W 675.54W 678.24W

90VAC 28.17A 25.02A 14.13A


Derating Curve

Advertisements

··· Ezoic
Efficiency vs Load (48V Model)

Function Manual

Remote Sense
The remote sensing compensates voltage drop on the load wiring up to
0.5V.

Advertisements
···

Ezoic

The +S signal should be connected to the positive terminal of the load


whereas-S signal to the negative terminal.
By factory default, on CN50, Remote ON-OFF (pin13) and 12V-AUX
(pin14), PV(pin5) and PS (pin6), and PC (pin7) and PO (pin8, respectively,
are shorted when shipped. The power supply wll have no output if the
shorting connector is not assembled unless certain functin needs to be
activated.

Remote ON-OFF

Advertisements

···

Ezoic

The power supply can be turned ON/OFF by using the “Remote ON-OFF”
function.
Advertisements

···
Ezoic

Between Remote ON-OFF(pin13) and 12V-AUX(pi


Power Supply Status
n14)

SW close (Short) ON

SW open (Open) OFF

When multiple power supplies need to turn ON/OFF simultaneously by


Remote ON-OFF control, -S & -V on CN50, as well as +S & +V, on each
power supply should be connected

Advertisements

···
Ezoic

Output Voltage Programming (or, PV / remote voltage programming


/ remote adjust / margin programming / dynamic voltage trim)

Advertisements
···

Ezoic

In addition to the adjustment via the built-in potentiometer, the output


voltage can be trimmed to 40~110% of the nominal voltage by applying
EXTERNAL VOLTAGE

If EXTERNAL VOLTAGE (VDC) <0.5V,the power supply may enter


under voltage protection; it needs to be restarted to work.
Caution: By factory default, the Output Voltage Programming is not
activated, and PV (pin5) and PS(pin6) are shorted by connector.
Whenever this function is not needed to activate, as assumed in other
sections’ diagrams, please keep PV (pin5) and PS(pin6) shorted ; other
wise, the power supply will have no output.

Constant Current Level Programming (or, PC / remote current


programming / dynamic current trim)
The constant current level can be trimmed to 40~110% of the rated
current by applying EXTERNAL VOLTAGE.

Caution: By factory default, the Output Current Programming is not


activated, and PC(pin7) and PO(pin8) are shorted by connector.
Whenever this function is not needed to activate, as assumed in other
sections’ diagrams, please keep PC(pin7) and PO(pin8) shorted ;
otherwise, the power supply will have no output.

DC_OK signal
“DC_OK” is an open collector signal. It indicates the output ※ status of
the power supply. It can operate in two ways : One is sinking current
from external TTL signal ; the other is sending out a TTL voltage signal.

Sinking current from external TTL signal: The maximum sink current
is 10mA and the maximum external voltage is 5.6V.
Sending out TTL voltage signal

Between DC- OK(pin9) and GND(pin10&11) Output Status

0 ~ 1V Power supply ON

3.3 ~ 5.6V Power supply OFF


Mechanical Specification

Mounting Instruction

Hole Recommended MAX. Penetration D Recommended mounting t


No. Screw Size epth L orque

1 M4 6mm 7~11Kgf-cm

2 M4 4mm 7~11Kgf-cm
Control Pin No. Assignment (CN50) : HRS DF11-14DP-2DS or equivalent

Advertisements

···
Ezoic

Mating Housing HRS DF11-14DS or equivalent

Terminal HRS DF11-**SC or equivalent


Pi Fu
n nc
Description
N ti
o. on

+
1 Positive sensing for remote sense.
S

+
+V Signal. The +VS should be connected to the +S to reduce the n
2 V
oise when “output voltage programming” function is in use.
S

3 -S Negative sensing for remote sense.

-V -V Signal. The -VS should be connected to the -S to reduce the noi


4
S se when “output voltage programming” function is in use.

P Connect to external DC voltage source for output voltage progra


5
V mming, referenced to pin 10,11 (GND).

P Reference pin regarding output voltage programming. Please refe


6
S r to the Function Manual.

P Connect to external DC voltage source for output current program


7
C ming.

P Reference pin regarding output current programming. Please refe


8
O r to the Function Manual.

D
Open collector signal, referenced to pin10,11(GND). Low when PS
C_
9 U turns on. The maximum sink current is 10mA and the maximu
O
m external voltage is 5.6V.
K

1 G
These pins connect to the negative terminal (-V). Return for DC_O
0, N
K Signal output.
11 D

G- Auxiliary voltage output ground.


A
12
U The signal return is isolated from the output terminals (+V & -V).
X
R
E
M
O
Turns the output on and off by electrical or dry contact between p
T
13 in 13 ( ON/OFF) and pin 14 (12V-AUX). Short: Power ON, Open: Po
E
wer OFF.
O
N-
O
FF

12 Auxiliary voltage output, 10.8~13.2V, referenced to pin 12(G-AU


V- X).
14 A
The maximum load current is 0.1A. This output is not controlled b
U
y the “remote ON/OFF control”.
X

AC Input Terminal Pin No. Assignment

DC Output Terminal Pin No. Assignment

Installation Manual
Please refer to : http://www.meanwell.com/manual.html
File Name: RSP-750-SPEC 2022-08-08
Documents / Resources

MEAN WELL RSP-750 Series 750W Power Supply with Sin


gle Output [pdf] Owner's Manual
RSP-750 Series 750W Power Supply with Single Output, RS
P-750 Series, 750W Power Supply with Single Output, Power
Supply with Single Output, Supply with Single Output, Single
Output, Output

MEAN WELL RSP-750 Series 750W Power Supply with Sin


gle Output [pdf] Owner's Manual
RSP-750-5, RSP-750-12, RSP-750-15, RSP-750-24, RSP-750-
27, RSP-750-48, RSP-750 Series 750W Power Supply with Si
ngle Output, 750W Power Supply with Single Output, Supply
with Single Output, Single Output

References

User Manual

Manuals+ | Upload | Deep Search | Privacy Policy | @manuals.plus | YouTube

This website is an independent publication and is neither affiliated with nor endorsed by any of the trademark owners. The "Bluetooth®"
word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. The "Wi-Fi®" word mark and logos are registered trade‐
marks owned by the Wi-Fi Alliance. Any use of these marks on this website does not imply any affiliation with or endorsement.

You might also like