Features: 62 Series - Power Relays 16 A

The 62 Series Power Relays are designed for printed circuit and plug-in mounting, featuring 16 A capacity with options for 2 or 3 pole changeover and normally open contacts. They offer AC and DC coil compatibility, reinforced insulation, and various contact materials, including cadmium-free options. The relays are suitable for a wide range of applications with specifications for voltage, load, and environmental protection.

Uploaded by

Alex Ivanov
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
12 views10 pages

Features: 62 Series - Power Relays 16 A

The 62 Series Power Relays are designed for printed circuit and plug-in mounting, featuring 16 A capacity with options for 2 or 3 pole changeover and normally open contacts. They offer AC and DC coil compatibility, reinforced insulation, and various contact materials, including cadmium-free options. The relays are suitable for a wide range of applications with specifications for voltage, load, and environmental protection.

Uploaded by

Alex Ivanov
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

62 Series - Power relays 16 A

Features 62.22 / 62.23 62.22-0300 / 62.23-0300


Printed circuit mount
16 A Power relay
•2 & 3 Pole changeover contacts
or NO (≥ 3 mm contact gap)
• AC coils & DC coils
• Reinforced insulation between coil and
contacts according to EN 60335-1,
with 6 mm clearance & 8 mm creepage
distance • 2 & 3 pole normally open contact
• 2 & 3 pole changeover contact
• SELV coil-contact separator option (≥ 3 mm contact gap)
• PCB mount
• PCB mount
• Cadmium Free contact material options

12 14 32 34 12 14 22 24 32 34 14 34 14 24 34
1 4 3 6 1 4 2 5 3 6 4 6 4 5 6
38.2 38.2 35.8 35.8

11 31 11 21 31 11 31 11 21 31
49.1

49.1

7 9 7 8 9 7 9 7 8 9

A1 A B A2 A1 A B A2 A1 A B A2 A1 A B A2
3.5

3.5

62
9.7

9.7

38.2 38.2 38.2 38.2


8 22.2 8 8 11.1 8 8.65 7.6 8.3 5.5 5.75 8.65 7.6 8.3 11.25 8 22.2 8 8 11.1 11.1 8 8 22.2 8 8 11.1 11.1 8
62.22 62.23 62.2x-0300 12 1 32 3 5.6 12 1 22 2 32 3 5.6
14 4 34 6 5.8 14 4 24 5 34 6 5.8 14 4 34 6 11.4 14 4 24 5 34 6 11.4
35.8

8
35.8

35.8

35.8
11 7 31 9 11 7 21 8 31 9 8 11 7 31 9 8 11 7 21 8 31 9 8
2

2
7.6 7.6 7.6 7.6
* Distance between contacts ≥ 3 mm A1 A A2 B 8.8 A1 A A2 B 8.8 A1 A A2 B 8.8 A1 A A2 B 8.8
(EN 60730-1).
** With the AgSnO2 material the maximum 62.22 62.23 62.22 - 0300 62.23 - 0300
peak current is 120 A - 5 ms (NO contact). Copper side view Copper side view Copper side view Copper side view

Contact specification
Contact configuration 2 CO (DPDT) 3 CO (3PDT) 2 NO (DPST-NO), ≥ 3 mm* 3 NO (3PST-NO), ≥ 3 mm*
Rated current/Maximum peak current A 16/30** 16/30**
Rated voltage/Maximum switching voltage V AC 250/400 250/400
Rated load AC1 VA 4,000 4,000
Rated load AC15 (230 V AC) VA 750 750
Motor rating (230/400 V AC) kW 0.8/— 0.8/1.5 0.8/— 0.8/1.5
Breaking capacity DC1: 30/110/220 V A 16/0.6/0.4 16/1.1/0.7
Minimum switching load mW (V/mA) 1,000 (10/10) 1,000 (10/10)
Standard contact material AgCdO AgCdO
Coil specification
Nominal voltage (UN) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400
V DC 6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
Rated power AC/DC VA (50 Hz)/W 2.2/1.3 3/3
Operating range AC (0.8…1.1)UN (0.85…1.1)UN
DC (0.8…1.1)UN (0.85…1.1)UN
Holding voltage AC/DC 0.8 UN/0.6 UN 0.8 UN/0.6 UN
Must drop-out voltage AC/DC 0.2 UN/0.1 UN 0.2 UN/0.1 UN
Technical data
Mechanical life AC/DC cycles 10 · 106/30 · 106 10 · 106/30 · 106
Electrical life at rated load AC1 cycles 100 · 103 100 · 103
Operate/release time ms 10/10 20/4
Insulation between coil and contacts (1.2/50 µs) kV 6 6
Dielectric strength between open contacts V AC 1,500 2,500
Ambient temperature range °C –40…+70 –40…+50
Environmental protection RT I RT I
Approvals (according to type)

95
62 Series - Power relays 16 A
Features 62.32 / 62.33 62.32-0300 / 62.33-0300
Plug-in mount/Faston 187
16 A Power relay
• Plug-in (92 series sockets) or
Faston 187 (4.8x0.5 mm) with optional
mounting adaptors
• 2 & 3 Pole changeover contacts
or NO (≥ 3 mm contact gap)
• AC coils & DC coils
• UL Listed (certain relay/socket • 2 & 3 pole normally open contact
• 2 & 3 pole changeover contact
combinations) (≥ 3 mm contact gap)
• Plug-in / Faston 187
• Plug-in / Faston 187
• LED, mechanical indicator & test button
options
12 14 32 34 12 14 22 24 32 34 14 34 14 24 34
• Reinforced insulation between coil and 4 5 6
1 4 3 6 1 4 2 5 3 6 4 6
contacts according to EN 60335-1,
with 6 mm clearance & 8 mm creepage
distance 11 31 11 21 31 11 31 11 21 31
7 9 7 8 9 7 9 7 8 9
• SELV coil-contact separator option
A1 A B A2
• Cadmium Free contact material options A1 A B A2 A1 A B A2 A1 A B A2

• Sockets and accessories 62.32 62.33 62.32-0300 62.33-0300


62
38.2 38.2 35.8 38.2 38.2 35.8

47.6
47.6

* Distance between contacts ≥ 3 mm

3.5
3.5

3
(EN 60730-1).
** With the AgSnO2 material the maximum

9.7
9.7

8 22.2 8 8 11.1 8 8.65 7.6 8.35.55.75 8 22.2 8 8 11.1 8 8.65 7.6 8.3 11.25
peak current is 120 A - 5 ms (NO contact).
62.32 62.33 62.320-00 62.33-0300

Contact specification
Contact configuration 2 CO (DPDT) 3 CO (3PDT) 2 NO (DPST-NO), ≥ 3 mm* 3 NO (3PST-NO), ≥ 3 mm*
Rated current/Maximum peak current A 16/30** 16/30**
Rated voltage/Maximum switching voltage V AC 250/400 250/400
Rated load AC1 VA 4,000 4,000
Rated load AC15 (230 V AC) VA 750 750
Motor rating (230/400 V AC) kW 0.8/— 0.8/1.5 0.8/— 0.8/1.5
Breaking capacity DC1: 30/110/220 V A 16/0.6/0.4 16/1.1/0.7
Minimum switching load mW (V/mA) 1,000 (10/10) 1,000 (10/10)
Standard contact material AgCdO AgCdO
Coil specification
Nominal voltage (UN) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400
V DC 6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
Rated power AC/DC VA (50 Hz)/W 2.2/1.3 3/3
Operating range AC (0.8…1.1)UN (0.85…1.1)UN
DC (0.8…1.1)UN (0.85…1.1)UN
Holding voltage AC/DC 0.8 UN/0.6 UN 0.8 UN/0.6 UN
Must drop-out voltage AC/DC 0.2 UN/0.1 UN 0.2 UN/0.1 UN
Technical data
Mechanical life AC/DC cycles 10 · 106/30 · 106 10 · 106/30 · 106
Electrical life at rated load AC1 cycles 100 · 10 3
100 · 103
Operate/release time ms 10/10 20/4
Insulation between coil and contacts (1.2/50 µs) kV 6 6
Dielectric strength between open contacts V AC 1,500 2,500
Ambient temperature range °C –40…+70 –40…+50
Environmental protection RT I RT I
Approvals (according to type)

96
62 Series - Power relays 16 A
Features 62.82 / 62.83 62.82-0300 / 62.83-0300
Flange mount/Faston 250
16 A Power relay
• Faston 250 (6.3x0.8 mm) termination
Flange or optional mounting adaptors
• 2 & 3 Pole changeover contacts
or NO (≥ 3 mm contact gap)
• AC coils & DC coils
• LED, mechanical indicator
& test button options • 2 & 3 pole normally open contact
• 2 & 3 pole changeover contact
• Reinforced insulation between coil and (≥ 3 mm contact gap)
• Flange mount / Faston 250
• Flange mount / Faston 250
contacts according to EN 60335-1,
with 6 mm clearance & 8 mm creepage 12 14 32 34 12 14 22 24 32 34 14 34 14 24 34
distance 1 4 3 6 1 4 2 5 3 6 4 6 4 5 6

• SELV coil-contact separator option


• Cadmium Free contact material options
11 31 11 21 31 11 31 11 21 31
7 9 7 8 9 7 9 7 8 9

A1 A B A2 A1 A B A2 A1 A B A2 A1 A B A2
62.82 62.83 62.82-0300 62.83-0300

62
38.2 38.2 35.8 38.2 38.2 35.8
3.6 3.6 3.6 3.6

47.6

47.6
63
68

63
68
63
68

63
68
* Distance between contacts ≥ 3 mm
9.7

9.7
(EN 60730-1).
** With the AgSnO2 material the maximum
8 22.2 8 8 11.1 8 8.8 7.6 8 5.8 5.6 8 22.2 8 8 11.1 8 8.8 7.6 8 11.4
peak current is 120 A - 5 ms (NO contact).
62.82 62.83 62.82-0300 62.83-0300

Contact specification
Contact configuration 2 CO (DPDT) 3 CO (3PDT) 2 NO (DPST-NO), ≥ 3 mm* 3 NO (3PST-NO), ≥ 3 mm*
Rated current/Maximum peak current A 16/30** 16/30**
Rated voltage/Maximum switching voltage V AC 250/400 250/400
Rated load AC1 VA 4,000 4,000
Rated load AC15 (230 V AC) VA 750 750
Motor rating (230/400 V AC) kW 0.8/— 0.8/1.5 0.8/— 0.8/1.5
Breaking capacity DC1: 30/110/220 V A 16/0.6/0.4 16/1.1/0.7
Minimum switching load mW (V/mA) 1,000 (10/10) 1,000 (10/10)
Standard contact material AgCdO AgCdO
Coil specification
Nominal voltage (UN) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400
V DC 6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
Rated power AC/DC VA (50 Hz)/W 2.2/1.3 3/3
Operating range AC (0.8…1.1)UN (0.85…1.1)UN
DC (0.8…1.1)UN (0.85…1.1)UN
Holding voltage AC/DC 0.8 UN/0.6 UN 0.8 UN/0.6 UN
Must drop-out voltage AC/DC 0.2 UN/0.1 UN 0.2 UN/0.1 UN
Technical data
Mechanical life AC/DC cycles 10 · 106/30 · 106 10 · 106/30 · 106
Electrical life at rated load AC1 cycles 100 · 10 3
100 · 103
Operate/release time ms 10/10 20/4
Insulation between coil and contacts (1.2/50 µs) kV 6 6
Dielectric strength between open contacts V AC 1,500 2,500
Ambient temperature range °C –40…+70 –40…+50
Environmental protection RT I RT I
Approvals (according to type)

97
62 Series - Power relays 16 A

Ordering information
Example: 62 series power relay + Faston 250 (6.3x0.8 mm), rear flange mount, 2 NO (DPST-NO), 12 V DC coil.

A B C D

6 2 . 8 2 . 9 . 0 1 2 . 0 3 0 0
Series A: Contact material D: Special versions
0 = Standard AgCdO 0 = Standard
Type
4 = AgSnO2 5 = Top flange mount
2 = PCB
6 = Rear flange mount
3 = Plug-in B: Contact circuit
7 = Top 35 mm rail mount
8 = Faston 250 (6.3x0.8 mm) 0 = CO (nPDT)
8 = Rear 35 mm rail mount
with rear flange mount 3 = NO (nPST),
9 = Type 62.82/83 without rear flange mount
≥ 3 mm contact gap
No. of poles
5 = CO (nPDT) + additional C: Options
2 = 2 pole
physical separator between 0 = None
3 = 3 pole
coil and contacts (for SELV 2 = Mechanical indicator
Coil version applications) 3 = LED (AC)
8 = AC (50/60 Hz) 6 = NO (nPST), ≥ 3 mm contact 4 = Lockable test button +
9 = DC gap + additional physical mechanical indicator
separator between coil and 5 = Lockable test button + LED (AC)
Coil voltage
contacts (for SELV 54 = Lockable test button + LED (AC) +
62 see coil specifications
applications) mechanical indicator
6 = LED + diode
Selecting features and options: only combinations in the same row are possible.
(DC, polarity positive to pin A/A1)
Preferred selections for best avaliability are shown in bold.
7 = Lockable test button + LED + diode
Type Coil version A B C D (DC, polarity positive to pin A/A1)
62.22/23 AC-DC 0-4 0-3-5-6 0 0 74 = Lockable test button + LED + diode
62.32/33 AC-DC 0-4 0-3-5-6 0 0-5-6-7-8 (DC, polarity positive to pin A/A1) +
AC-DC 0-4 0-5 2-4 0-6-8 mechanical indicator
AC 0-4 0 2-3-4-5 0-6-8
AC 0-4 0-3 3 0-6-8
AC 0-4 0 54 /
DC 0-4 0 4-6-7 0-6-8
DC 0-4 0-3 6 0-6-8
DC 0-4 0 74 /
62.82/83 AC-DC 0-4 0-3-5-6 0 0-5-7-8-9
AC-DC 0-4 0-5 2-4 0-8
AC 0-4 0 2-3-4-5 0-8
AC 0-4 0-3 3 0-8
DC 0-4 0 4-6-7 0-8
DC 0-4 0-3 6 0-8

Descriptions: Options and Special versions

52.3

A B A B

C: Option 3, 5, 54 C: Option 6, 7, 74 D: Special versions 5 D: Special versions 7 B: Contact circuit 5, 6


LED (AC) LED + diode (DC, polarity Top flange mount Top 35 mm rail mount Additional physical separator
positive to pin A/A1) between coil and contacts (for
SELV applications)

Lockable test button and mechanical flag indicator (0040)


The dual-purpose Finder test button can be used in two ways:
Case 1) The plastic pip (located directly above the test button) remains intact. In this case, when the
test button is pushed, the contacts operate. When the test button is released the contacts return to their
former state.
Case 2) The plastic pip is broken-off (using an appropriate cutting tool). In this case, (in addition to
the above function), when the test button is pushed and rotated, the contacts are latched in the
operating state, and remain so until the test button is rotated back to its former position.
In both cases ensure that the test button actuation is swift and decisive.
98
62 Series - Power relays 16 A

Technical data
Insulation
Insulation according to EN 61810-1 ed. 2 insulation rated voltage V 400
rated impulse withstand voltage kV 4
pollution degree 3
overvoltage category III
Insulation between coil and contacts (1.2/50 µs) kV 6
Dielectric strength between open contacts V AC 1,500 (changeover contact types)
V AC 2,500 (normally open contact types)
Dielectric strength between adjacent contacts V AC 2,500
Conducted disturbance immunity
Burst (5...50)ns, 5 kHz, on A1 - A2 EN 61000-4-4 level 4 (4 kV)
Surge (1.2/50 µs) on A1 - A2 (differential mode) EN 61000-4-5 level 4 (4 kV)
Other data
Bounce time: NO/NC ms 3/6 (changeover) 3/— (normally open)
Vibration resistance (5…55)Hz, max. ± 1 mm: NO/NC g/g 5/3
Shock resistance g 15
Power lost to the environment 2 pole (CO) 3 pole (CO) 2 pole (NO) 3 pole (NO)
without contact current W 1.3 1.3 3 3 62
with rated current W 3.3 4.3 5 6
Recommended distance between relays mounted on PCB mm ≥ 5

Contact specification
F 62 - Electrical life (AC) v contact current
7
10

Resistive load - cosϕ = 1


Cycles

6 Inductive load - cosϕ = 0.4


10

5
10
0 4 8 12 16
(A)

H 62 - Maximum DC1 breaking capacity H 62 - Maximum DC1 breaking capacity


Changeover contacts Normally open contacts

20 20
1 2 3 contacts in series 1 2 3 contacts in series
10
DC breeaking current (A)

10
DC breaking current (A)

6 6
4 4

2 2

1 1

0.2 0.2

0.1 0.1
20 60 100 140 180 220 20 60 100 140 180 220
Voltage DC (V) Voltage DC (V)

• When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of ≥ 100·103 can be expected.
• In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load.
Note: the release time of the load will be increased.

99
62 Series - Power relays 16 A

Coil specifications
DC version data AC version data
Nominal Coil Operating range Resistance Rated coil Nominal Coil Operating range Resistance Rated coil
voltage code consumption voltage code consumption
UN Umin Umax R I at UN UN Umin Umax R I at UN (50Hz)
V V V Ω mA V V V Ω mA
6 9.006 4.8 6.6 28 214 6 8.006 4.8 6.6 4.6 367
12 9.012 9.6 13.2 110 109 12 8.012 9.6 13.2 19 183
24 9.024 19.2 26.4 445 54 24 8.024 19.2 26.4 74 90
48 9.048 38.4 52.8 1,770 27 48 8.048 38.4 52.8 290 47
60 9.060 48 66 2,760 21.7 60 8.060 48 66 450 37
110 9.110 88 121 9,420 11.7 110 8.110 88 121 1,600 20
125 9.125 100 137.5 12,000 10.4 120 8.120 96 132 1,940 18.6
220 9.220 176 242 37,300 5.8 230 8.230 184 253 7,250 10.5
240 8.240 192 264 8,500 9.2
400 8.400 320 440 19,800 6

DC (NO/nPST-NO) version data (≥ 3 mm) AC (NO/nPST-NO) version data (≥ 3 mm)


Nominal Coil Operating range Resistance Rated coil Nominal Coil Operating range Resistance Rated coil
voltage code consumption voltage code consumption
UN Umin Umax R I at UN UN Umin Umax R I at UN (50Hz)
62 V V V Ω mA V V V Ω mA
6 9.006 5.1 6.6 12 500 6 8.006 5.1 6.6 4 540
12 9.012 10.2 13.2 48 250 12 8.012 10.2 13.2 14 275
24 9.024 20.4 26.4 192 125 24 8.024 20.4 26.4 62 130
48 9.048 40.8 52.8 770 63 48 8.048 40.8 52.8 220 70
60 9.060 51 66 1,200 50 60 8.060 51 66 348 55
110 9.110 93.5 121 4,200 26 110 8.110 93.5 121 1,200 30
125 9.125 106.2 137.5 5,200 24 120 8.120 106 137 1,350 24
220 9.220 187 242 17,600 12.5 230 8.230 196 253 5,000 14
240 8.240 204 264 6,300 12.5
400 8.400 340 440 14,700 7.8

R 62 - DC coil operating range v ambient temperature R 62 - AC coil operating range v ambient temperature
Changeover contacts Changeover contacts

U U
2.0 2.0
UN UN

1.5 1.5

1
1.0 1
1.0
2
2
0.5 0.5
-20 -10 0 10 20 30 40 50 60 70 -20 -10 0 10 20 30 40 50 60 70 80
(°C) (°C)

R 62 - DC coil operating range v ambient temperature R 62 - AC coil operating range v ambient temperature
Normally open contacts Normally open contacts

U 2.0 U 2.0
UN UN

1.5 1.5

1 1
1.0 1.0
2 2
0.5 0.5
-20 -10 0 10 20 30 40 50 60 -20 -10 0 10 20 30 40 50 60
(°C) (°C)

1 - Max. permitted coil voltage. 1 - Max. permitted coil voltage.


2 - Min. pick-up voltage with coil at ambient temperature. 2 - Min. pick-up voltage with coil at ambient temperature.
100
62 Series - Power relays 16 A

Accessories
Mounting adaptor for types 62.3x and 62.8x.xxxx.xxx9 (M4) 062.10
47,2

7,6
4,8
062.10

41
47,2
M4
062.10

Flange mounting adaptor for types 62.3x and 62.8x.xxxx.xxx9 062.60


41
37.2

062.60

62
1.4

52.3
6
3.
17.3
13

062.60

Sheet of marker tags for 62 series relays, plastic, 72 tags, 6x12 mm 060.72

060.72

101
92 Series - Sockets and accessories for 62 series relays

Screw terminal (Box clamp) socket 92.03 (blue) 92.03.0 (black)


panel or 35 mm rail (EN 50022) mount
For relay type 62.32, 62.33 62.32, 62.33
Accessories
Metal retaining clip (supplied with socket - packaging code SMA) 092.71
92.03
Identification tag 092.00.2
Approvals Modules (see table below) 99.02
(according to type): Timer modules (see table below) 86.00, 86.10, 86.20
Technical data
Rated values 16 A - 250 V
Insulation ≥ 6 kV (1.2/50 µs) between coil and contacts
Protection category IP 20
Ambient temperature °C –40…+70
Screw torque Nm 0.8
Wire strip length mm 10
Max. wire size for 92.03 socket solid wire stranded wire
mm2 1x10 / 2x4 1x6 / 2x4
AWG 1x8 / 2x12 1x10 / 2x12
40 60.9
35.5 30.25
27
62 9
31
8
21
7
11 COM
34.3

6 5 4
34 24 14 NO

3 2 1
32 22 12 NC
3.2
91.3

35.4
46.3

21.6

B A
A2 A1 COIL

32

86 series timer modules (see technical data pages 181/182/188)


Multi-voltage: (12…240)V AC/DC;
Multi-functions: AI, DI, SW, BE, CE, DE, EE, FE; (0.05s…100h) 86.00.0.240.0000
Mono-function: (12…24)V AC/DC; function AI; (1.5s…60min) 86.10.0.024.0000
Mono-function: (12…24)V AC/DC; function DI; (1.5s…60min) 86.20.0.024.0000
86.00
Approvals
(according to type):

86.10

99.02 coil indication and EMC suppression modules for 92.03 socket
See technical data pages 247/248 Blue*
Diode (+A1, standard polarity) (6...220)V DC 99.02.3.000.00
Diode (+A2, non standard polarity) (6...220)V DC 99.02.2.000.00
LED (6...24)V DC/AC 99.02.0.024.59
99.02
LED (28...60)V DC/AC 99.02.0.060.59
Approvals LED (110...240)V DC/AC 99.02.0.230.59
(according to type): LED + Diode (+A1, standard polarity) (6...24)V DC 99.02.9.024.99
LED + Diode (+A1, standard polarity) (28...60)V DC 99.02.9.060.99
LED + Diode (+A1, standard polarity) (110...220)V DC 99.02.9.220.99
LED + Diode (+A2, non standard polarity) (6...24)V DC 99.02.9.024.79
LED + Diode (+A2, non standard polarity) (28...60)V DC 99.02.9.060.79
* Modules in Black
LED + Diode (+A2, non standard polarity) (110...220)V DC 99.02.9.220.79
housing are
available on request. LED + Varistor (6...24)V DC/AC 99.02.0.024.98
LED + Varistor (28...60)V DC/AC 99.02.0.060.98
LED + Varistor (110...240)V DC/AC 99.02.0.230.98
RC circuit (6...24)V DC/AC 99.02.0.024.09
RC circuit (28...60)V DC/AC 99.02.0.060.09
RC circuit (110...240)V DC/AC 99.02.0.230.09
Residual current by-pass (62 kΩ/1W) (110...240)V AC 99.02.8.230.07
102
92 Series - Sockets and accessories for 62 series relays

PCB socket 92.13 (blue) 92.13.0 (blue)


For relay type 62.32, 62.33 62.32, 62.33
Accessories
Metal retaining clip (supplied with socket - packaging code SMA) 092.54
Technical data
92.13
Rated values 16 A - 250 V (10 A max for each contact circuit)
Approvals Dielectric strength ≥ 2.5 kV AC
(according to type): Ambient temperature °C –40…+70
40 1 38 1 19.3
= 11.1 11.1 = 8.3 6.5

7.4
5.5

1.6
121 222 323

36
8.3

36
144 245 346
117 218 319 7.6
7.1
A1A A2B
3.4

62.3x plug on 92.13 is 63.3 mm high

62

Panel mount solder socket mounted with M3 screw 92.33 (blue)


For relay type 62.32, 62.33
Accessories
Metal retaining clip (supplied with socket - packaging code SMA) 092.54
Technical data
92.33
Rated values 16 A - 250 V (10 A max for each contact circuit)
Approvals Dielectric strength ≥ 2.5 kV AC
(according to type): Ambient temperature °C –40…+70

11.1 1 38 1 21.3
4.5 8 8.3 6.5
3.8
=
42.5

50
31

121 222 323


144 245 346
=

117 218 319

A1A A2B
11.1
4.5 3.4
35.5

Packaging code
How to code and identify retaining clip and packaging options for sockets.

Code options according to the last three letters:

9 2 . 0 3 S M A

A Standard packaging

SM Metal retaining clip

9 2 . 0 3 Without retaining clip

103

You might also like