0% found this document useful (0 votes)
27 views16 pages

JBC Rmse 2QF - en

The DDE 2-Tool Control Unit manual provides instructions for setup, operation, and maintenance of the unit, which can control up to two tools simultaneously. It includes a packing list, compatibility information, and advanced functionalities such as real-time graphics for soldering analysis and temperature control features. Additionally, the manual outlines troubleshooting steps and maintenance tips to ensure optimal performance of the equipment.

Uploaded by

DMITRYHAGGARD
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
27 views16 pages

JBC Rmse 2QF - en

The DDE 2-Tool Control Unit manual provides instructions for setup, operation, and maintenance of the unit, which can control up to two tools simultaneously. It includes a packing list, compatibility information, and advanced functionalities such as real-time graphics for soldering analysis and temperature control features. Additionally, the manual outlines troubleshooting steps and maintenance tips to ensure optimal performance of the equipment.

Uploaded by

DMITRYHAGGARD
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 16

INSTRUCTION MANUAL

DDE
2-Tool Control Unit
This manual corresponds to the following reference:

DDE-9C (100 V)
DDE-1C (120 V)
DDE-2C (230 V)

Packing List
The following items are included:

2-Tool Power Cord .................... 1 unit Manual ...............................1 unit


Control Unit .................... 1 unit Ref. 0024077 (100V) Ref. 0027023
0023717 (120V)
0024080 (230V)

Features

DDE work simultaneously with up to 2 tools and 1 module + 1 pedal for each tool (peripheral module
for each tool needed).

Display
USB-A connector

Tilt the display


for easy reading Main Switch

2
200 mm para manuales - color gris

Connection Example 130 mm 130 mm

DDE 2-Tool Control Unit

100 mm

Equipotential
connector

80 mm USB-B
connector

Power Socket
Stand Cable*
Ref. 0024227 60 mm
RJ12 connector

T245*
General
Stand Cable* DR560*
Purpose
50 mm

Ref. 0024227 Desoldering Iron


Handle

40 mm

DRS*
Stand for
ADS* DR560
Stand for Desoldering
T210 & T245 Iron
Handles

Suction
Filter*
Ref. 0821830

Module Cable* MSE*


Ref. 0024228 Electric Desoldering
Module for DDE & DME

To another Peripheral

* not included To Pedal P005

3
Compatibility

Select the equipment that best suit your soldering or desoldering needs.

Modular System Peripherals


Control Cartridge
Stand Tool MSE / MVE MNE P405
Unit Range

T210 C210

ADS T245
C245
T470

T210N C210
DNS
T245N C245

APS AP250 C250


DDE
AM120
AMS C120
PA120

ATS AT420
C420
HTS HT420

DSS DS360 C360

DRS DR560 C560

4
200 mm para manuales - color gris

DDE Work Display 130 mm 130 mm

DDE offers an intuitive user interface which provides quick access to station parameters.
Default PIN: 0105

100 mm

Status Bar 19:29


80 mm

T245 T245

350
Tool
ºC in use
60 mm Sleep
Tool in the stand
Power
Temp levels Actual Temp. 180º
Indicator
Delay to hibernation: 29:30
50 mm

Power
250 350 380 Port
Displayed if 45% 1
Temperature
Levels are 40 mm
Activated
19:29 Station
Information

Peripherals Port 2-PA Change


Peripherals
Port
Pedal None Pedal
Module
Module None Module
MSE_a
None

Menu Options

Set the station Set the tool Display the hours


parameters parameters worked in each cycle

19:29
Station Tools Counters

It is possible to Peripherals Port 2-PA


Restore station Peripherals
choose the language parameters to default
Pedal PD_a Pedal
from a list values
Pedal
Module MSE Function
PD_a
Language Reset Mode
PD_b
Minimum time
None
Back
Troubleshooting

Station troubleshooting available on the product page at www.jbctools.com

5
Advanced Functionalities

It provides detailed graphics of tip temperature and power delivery in real time during
solder joint formation for analysis purposes. This helps you decide how to adjust your
process or which tip to use to obtain the best quality soldering.
Graphics

Designed to avoid thermal shock when soldering Ceramic Chip components like MLCC,
this new and unique feature allows controlling the heating rate to gradually increase the
temperature of the component through all the phases of the soldering process. Up to 25
fully configurable soldering profiles can be stored.
Profiles

Export graphics
Insert a USB flash drive into the USB-A
connector to save your soldering
process in csv format.
Files

Station update
Download the JBC Update File from
www.jbctools.com/software.html
Insert the USB flash drive with the file
downloaded to the station.
Update

System Notifications

The following icons will be displayed on the screen’s status bar.

USB flash drive is connected. Station software update. Press INFO to start
the process.

Station is controlled by a PC. Warning. Press INFO for failure description.

Station is controlled by a robot down- Error. Press INFO for failure description,
loaded to the station. the type of error and how to proceed.

6
350 ºC
200 mm para manuales - color gris
Sle
Tool in
Temp levels Actual
Delay
19:29
Power
250 350 380 Port
Peripheral Set Up 130 mm 45%
T245
130 mm1

1. After connecting the module, enter


the Peripherals Menu and select the port
which you want to join with the module.
100 mm
350
Peripherals Temp levelsPort 2-PA
ºC
19:29 S
A
Perip
T

D
Pedal None Pedal
Module 250 350 380
2. Select the module from the list of Module
None Modu
Power Port
peripheral connections. Remember your 45% MSE_a 1
first connection is denoted as “a”, the None
second being “b”, etc. (e.g. MS_a,
80 mm
MS_b,...). 19:29
19:29
19:29 19:29 19:29
19:29
3. Press Menu or BackT245
to save changes. T245
T245 Peripherals Port 2-PA T245 P
T245

350 ºC Up
PedalSleep Hibernation
60 mm Pedal None P
Set
Sleep Hibernation
Module 19:29
Module None M
Tool in the stand Actual Temp. 25ºC MSE_a
1. Enter the Peripherals Menu and select
Tool in thethe
stand 2. Select the pedal fromNone
the Actual
list Temp. that
(Note
your 25ºC
Actual Temp. 180º
Actual Temp. 180º
Peripherals Port 2-PA Perip
Temp levels
port which you
Delay want to 50join
to hibernation: 29:30 to
the pedal.
mm first connection is denoted as “a”, the second
Delay to hibernation: 29:30 Pedal PD_a Pedal
Port being “b”, etc. (e.g. PD_a,
Pedal PD_b,...).
Port
Port Module MSE
250 350 380 Port 1 Port PD_a 1
Funct
1
1 1 Mode
PD_b
40 mm Minim
None
19:29 19:29
19:29 19:29

PA Peripherals Port 2-PA Peripherals Port 2-PA P


Peripherals Port 2-PA Peripherals Port 2-PA
ne Pedal PD_a Pedal PD_a P
Pedal None Pedal PD_a Pedal
ne Module Module MSE Module MSE F
Module None Module MSE PD_a
MSE_a M
PD_b
None M
None

3. Set the pedal function according to your work needs:


19:29
Select how 19:29
the pedal 19:29

acts: as Sleep, Set the duration


PA Peripherals Port 2-PA
Peripherals
D_a
(hibernation)
ExtractorPort 2-PA Peripherals Port 2-PA of the activation
Pedal PD_a
Pedal or as a module switch.
PD_a Pedal PD_a
time when pressing
SE Pedal Function Extractor
Module MSE Function Extractor
the pedal once*.
PD_a Mode released For continuous
Mode released
PD_b Minimum time 0 sec functioning keep the
Minimum time 0 sec
Select
Nonethe activating Back pedal pressed.
Back
mode of the pedal
(pressed/released)

*NB: The same can be applied inversely when continually pressing the pedal and releasing to activate.

7
Operation
JBC’s Most Efficient Soldering System

Our revolutionary technology is able to recover tip temperature extremely quickly. It means the user
can work at a lower temperature and improve the soldering quality. The tip temperature is further
reduced thanks to the Sleep and Hibernation modes which increase up to 5 times the life of the tip.

1. Work 2. Sleep 3. Hibernation

Long period
in the stand

When the tool is lifted from the When the tool is in the stand, the After longer periods of inactivity,
stand the tip will heat up to the temperature falls to the preset the power is cut off and the tool
selected Work temperature. Sleep temperature. cools down to room temperature.

19:29 19:29
19:29
19:29
19:29
19:29
19:29 19:29
19:29

T245 T245
T245
T245
T245
T245
T245 T245
T245

350
350 Temp
Templevels
Templevels
levels
ºC
ºC
ºC Sleep
Sleep
Sleep
Tool in the stand
Tool
Toolinin
Actual
Actual
the
the
stand
Temp.
stand
Actual Temp. 180º
Temp.180º
180º
Hibernation
Hibernation
Hibernation
Actual Temp. 25ºC
Actual
ActualTemp.
Temp.
25ºC
25ºC

Delay to hibernation: 29:30


Delay
Delay toto
hibernation:
hibernation:
29:30
29:30

Power
250
250
250 350
350
350 380
380
380 Port Port
Port
Port
Port
Port
Port
Power
Power Port
Port 11 1 11 1
45%
45%
45% 11 1

19:29 19:29
Tool Settings: 19:29
19:29 Tool Settings: 19:29
19:29 Tool Settings:
· Work Temp.
Peripherals Port 2-PA
· Sleep
Peripherals Port 2-PA
· Hibernation
Peripherals
Peripherals Port
Port2-PA
2-PA Peripherals
Peripherals Port
Port2-PA
2-PA
Pedal
Pedal
Pedal None
None
None Pedal
Pedal
Pedal PD_a
PD_a
PD_a
Module
Change Work temperature
Module
Module
Module
Module
Module
MSE_a
None
None
None Change Sleep temperature
Module
Module
Module MSE and
MSE
MSE Change Hibernation delay
MSE_a
MSE_a
from 90 to 450 None
ºC.
None
None set Sleep delay from 0 to 9 min from 0 to 60 min or no
or steps of ±5 ºC / ºF or no Sleep. Hibernation.

Tool Settings:
· Temp. Levels 19:29
19:29
19:29 19:29
19:29
19:29

PressPeripherals
, select Tool
Peripherals
Peripherals Settings
Port
Port
Port2-PA
2-PA
2-PA Peripherals
Peripherals
Peripherals Port
Port
Port2-PA
2-PA
2-PA
and activate
Pedal
Pedal
Pedal the Temp.PD_a
Pedal
Levels
PD_a
PD_a Pedal
Pedal
Pedal PD_a
PD_a
PD_a
Module Pedal
Pedal MSE
option.
Module
Module
PD_a
PD_a
PD_a
MSE
MSE Function
Function
Function Extractor
Extractor
Extractor
Mode
Mode
Mode released
released
released
PD_b
PD_b
PD_b Minimum
Minimum time
Minimumtime
time 00sec
0sec
sec
None
or steps of ± 5 ºC / ºF.
None
None Back
Back
Back

8
200 mm para manuales - color gris

Maintenance 130 mm 130 mm

Before carrying out maintenance or storage, always allow the equipment to cool.
100 mm
- Clean the station screen with a glass cleaner or a damp cloth.

Clean periodically
- Use a damp cloth to clean the casing and the
tool. Alcohol can only be used to clean the
metal parts. 80 mm

- Periodically check that the metal parts of the


tool and stand are clean so that the station can
detect the tool’s status.60 mm

- Maintain the tip surface clean and tinned before


storage in order to avoid tip oxidation. Rusty
and dirty surfaces reduce
50 mm heat transfer to the

solder joint.

- Periodically check all cables and tubes.


40 mm

- Replace a blown fuse as follows:

1. Pull off the fuse holder and remove the 2. Press the new fuse into the fuse holder
fuse. If necessary use a tool to lever it off. and replace it in the station.

Fuse

Fuse Holder
Fuse holder

- Replace any defective or damaged pieces. Use original JBC spare parts only.

- Repairs should only be performed by a JBC authorized technical service.

9
Safety

It is imperative to follow safety guidelines to prevent electric


shock, injury, fire or explosion.

- Do not use the units for any purpose other than soldering or rework. Incorrect use may cause a fire.

- The power cord must be plugged into approved bases. Be sure that it is properly grounded before
use. When unplugging it, hold the plug, not the wire.

- Do not work on electrically live parts.

- The tool should be placed in the stand when not in use in order to activate the sleep mode. The
soldering tip or nozzle, the metal part of the tool and the stand may still be hot even when the station
is turned off. Handle with care, including when adjusting the stand position.

- Do not leave the appliance unattended when it is on.

- Do not cover the ventilation grills. Heat can cause inflammable products to ignite.

- Avoid flux coming into contact with skin or eyes to prevent irritation.

- Be careful with the fumes produced when soldering.

- Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when working
to avoid personal harm.

- Utmost care must be taken with liquid tin waste which can cause burns.

- This appliance can be used by children over the age of eight and also people with reduced physical,
sensory or mental capabilities or lack of experience provided that they have been given adequate
supervision or instruction concerning the use of the appliance and understand the hazards involved.
Children must not play with the appliance.

- Maintenance must not be carried out by children unless supervised.

10
200 mm para manuales - color gris

Notes 130 mm 130 mm

100 mm

80 mm

60 mm

50 mm

40 mm

11
Notes

12
200 mm para manuales - color gris

Notes 130 mm 130 mm

100 mm

80 mm

60 mm

50 mm

40 mm

13
Notes

14
200 mm para manuales - color gris

Specifications 130 mm 130 mm

DDE
2-Tool Control Unit
Ref.: DDE-9C 100V 50/60Hz. Input fuse: T5A. Output: 23.5V
100 mm
Ref.: DDE-1C 120V 50/60Hz. Input fuse: T4A. Output: 23.5V
Ref.: DDE-2C 230V 50/60Hz. Input fuse: T2A. Output: 23.5V

- Nominal Power 370W


- Peak Power (Tool): 80 mm
150W per tool
- Selectable Temperature: 90 - 450 °C / 190 - 840 °F
- Idle Temp. Stability (still air): ±1.5ºC / ±3ºF / Meets and exceeds IPC J-STD-001F
- Temp Accuracy: ±3% (using reference cartridge)
- Temp Adjustment: 60 mm ±50ºC / ±90ºF Through station menu setting
- Tip to Ground Voltage/Resistance: Meets and exceeds
ANSI/ESD S20.20-2014 IPC J-STD-001F
- Ambient Operating Temp: 10 - 50 ºC / 50 - 122 ºF
- Connections: 50 mm USB-A / USB-B / Peripherals connectors
RJ12 connector
- Control Unit Dimensions/Weight: 148 x 232 x 120 mm / 3.82 kg
(L x W x H) 5.8 x 9.1 x 4.7 in / 8.41 lb
40 mm

- Total Package: 258 x 328 x 208 mm / 4.3 kg


10.15 x 12.9 x 8.1 in / 9.5 lb

Complies with CE standards.


ESD safe.

15
Warranty
JBC’s 2 year warranty covers this equipment against
all manufacturing defects, including the replacement
of defective parts and labour.
Warranty does not cover product wear or misuse.
In order for the warranty to be valid, equipment must
be returned, postage paid, to the dealer where it was
purchased.
Get 1 extra year JBC warranty by registering here:
https://www.jbctools.com/productregistration/
within 30 days of purchase.

This product should not be thrown in the garbage.


In accordance with the European directive 2012/19/EU, electronic equipment at the end of its life must
para manuales - color
be collected gris to an authorized recycling facility.
and returned
0027023-010623