0% found this document useful (0 votes)
100 views292 pages

UNISTRUT General Catalog

The Unistrut Metal Framing System offers engineered solutions and a wide range of products supported by a network of service centers across North America. The system features a unique weldless connection design that allows for easy and adjustable installations. Unistrut has been a leader in innovation for over 50 years, providing application solutions to simplify projects and save costs.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
100 views292 pages

UNISTRUT General Catalog

The Unistrut Metal Framing System offers engineered solutions and a wide range of products supported by a network of service centers across North America. The system features a unique weldless connection design that allows for easy and adjustable installations. Unistrut has been a leader in innovation for over 50 years, providing application solutions to simplify projects and save costs.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 292

The Unistrut®

Metal Framing System


…engineered solutions you can count on!

Products of UNISTRUT are manufactured un-


der one or more of the following United States
patents:
3,362,738 3,388,809 3,415,554
3,417,951 3,421,280 3,437,779
3,443,348 3,468,567 3,601,347
Meet Mr. Strut 3,617,076 3,618,882 3,628,296
Mr. Strut has symbolized Unistrut 3,721,463 3,861,107 3,877,275
innovation for over 50 years and 3,888,440 3,888,441 3,914,063
he’s still coming up with fresh 3,927,499 3,928,930 3,948,012
ideas and new ways to help you 3,968,624 3,994,111 4,073,114
work easier, faster and smarter! 4,277,923 4,278,288 4,289,415
So watch for Mr. Strut. When
Foreign patents and other patents pending
he’s around you’re never
far from the Unistrut
World of Support. The product Application SHOWCASE
Allows you to build a strong reputation with
a World of Support from Unistrut. It’s packed
with examples and application photos of the
Unistrut Framing System in action. Call for
your copy today.

Registered Trademarks of UNISTRUT:


“AXENT”, “UNISTRUT”, “P1000”, Marketing throughout the world by Unistrut:
“TELESPAR”, “TELESTRUT”, “UNI-CLIP”, Tel: (800) 521-7730 • www.unistrut.com
“UNICUSHION”, “UNIROD”, “GRAB BAG”,
“Prime Angle” and the cartoon character
“Mr. Strut”.
“SPF” is a Registered Trademarks of
Lord & Sons.
“Cush-A-Grip” is a Registered Trademarks of
ZSi.

When there’s work to be done,


build with the leader…
Unistrut®
The Unistrut World of Support
starts with our network of Unistrut
Service Centers across the nation.

T he Unistrut World of Support starts with our network of Unistrut


Service Centers across North America. They go far beyond
providing local product inventories... by offering complete applica-
tion solutions, based on experience gained from thousands of
projects worldwide.
It’s the kind of knowledgeable assistance that can help save time
and cost now, and simplify change in the future.
Technical help? No one knows the engineering side of Unistrut
support systems like your local Unistrut team. And if it’s special
fabrication, cutting or custom finishing you want, the pros at your
local Unistrut Service Center will make it happen...quickly, efficiently,
economically.
So when it’s help you need, call your Unistrut Service Center—
the quickest way to unlock Unistrut’s World of Support.
®
TABLE OF CONTENTS

INTRODUCTION . . . . . . . . . . . . . 1-20 TELESTRUT SYSTEM . . . . . . . . 63-74


®

Unistrut Metal Framing Systems . . . . . . . . . . 6-9 Telestrut Pictorial Index . . . . . . . . . . . . . . 64-66


Quality Assurance . . . . . . . . . . . . . . . . . . . . . . 10 Channels & Combinations . . . . . . . . . . . . 67-69
Materials and Finishes . . . . . . . . . . . . . . . . 11-13 Telestrut Connection Methods . . . . . . . . . . . . 70
Design Fundamentals . . . . . . . . . . . . . . . . 14-15 Wing Shape Fittings . . . . . . . . . . . . . . . . . . . . 71
Conversion Factors . . . . . . . . . . . . . . . . . . . . . 16 Post Bases . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Reference Tables and Data . . . . . . . . . . . . 17-18 Cutting Chart . . . . . . . . . . . . . . . . . . . . . . . . . 73
Guide Specification . . . . . . . . . . . . . . . . . . . . 19
New Products . . . . . . . . . . . . . . . . . . . . . . . . . 20 NUTS & HARDWARE . . . . . . . . 75-84
5
Nuts & Hardware Pictorial Index . . . . . . . . . . 76
1 ⁄ " CHANNEL . . . . . . . . . . . . . . 21-62
8 Channel Nut Loads . . . . . . . . . . . . . . . . . . . . . 77
Channel Pictorial Index . . . . . . . . . . . . . . 22-23 Channel Nuts . . . . . . . . . . . . . . . . . . . . . . 78-80
Channel Selection Chart . . . . . . . . . . . . . . . . . 24 Hardware . . . . . . . . . . . . . . . . . . . . . . . . . 81-84
Channels & Combinations . . . . . . . . . . . . 25-58
Closure Strips . . . . . . . . . . . . . . . . . . . . . . . . . 59 GENERAL FITTINGS . . . . . . . . 85-144
End Caps & Frame Caps . . . . . . . . . . . . . . . . . 60 General Fittings Pictorial Index . . . . . . . . 86-88
Load Reduction Charts . . . . . . . . . . . . . . . . . . 61 Design Load Data . . . . . . . . . . . . . . . . . . . . . . 89
Bearing Loads . . . . . . . . . . . . . . . . . . . . . . . . . 62 Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . 90-112
Post Bases . . . . . . . . . . . . . . . . . . . . . . . 113-114
Brackets . . . . . . . . . . . . . . . . . . . . . . . . 115-120
Brace Fittings . . . . . . . . . . . . . . . . . . . . 121-122
Beam Clamps . . . . . . . . . . . . . . . . . . . . 123-135
Trolley Assemblies . . . . . . . . . . . . . . . . 136-137
Special Application Fittings . . . . . . . . . 138-139
Seismic Retrofit Fittings . . . . . . . . . . . . 140-144

PIPE/CONDUIT SUPPORTS . . 145-170


Pipe & Conduit Pictorial Index . . . . . . . . . . 146
Pipe & Conduit Clamps . . . . . . . . . . . . 147-151
®
Unicushion . . . . . . . . . . . . . . . . . . . . . 152-153
®
Pipe & Tubing (Cush-A-Clamps ) Clamps 154-157
Pipe Hangers . . . . . . . . . . . . . . . . . . . . . . . . . 158
Pipe Rollers . . . . . . . . . . . . . . . . . . . . . . 159-161
Pipe Brackets . . . . . . . . . . . . . . . . . . . . 162-163
Pipe & Conduit Reference Data . . . . . . 164-170

ELECTRICAL FITTINGS . . . . . 171-192


Electrical Fittings Pictorial Index . . . . . . . . . 172
Electrical Fittings . . . . . . . . . . . . . . . . . 173-175
Receptacles . . . . . . . . . . . . . . . . . . . . . . . . . . 176
Fluorescent Fixture Hangers . . . . . . . . . . . . 177
Electrical Accessories . . . . . . . . . . . . . . 178-181
Junction Boxes . . . . . . . . . . . . . . . . . . . . . . . 182
In-Channel Joiners . . . . . . . . . . . . . . . . . . . . 183
Swivel Hangers . . . . . . . . . . . . . . . . . . . . . . . 184
Cable Entrance Tubing . . . . . . . . . . . . . 185-186
Cable Entrance Fittings . . . . . . . . . . . . . 187-188
Electrical Technical Data . . . . . . . . . . . 189-191
CONCRETE INSERTS . . . . . . . 193-202
Concrete Inserts Pictorial Index . . . . . . . . . 194
Installation & Heavy Duty Inserts . . . . . . . . . 195
Standard Duty & Accessories . . . . . . . . 196-197
Light Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . 198
Spot Inserts . . . . . . . . . . . . . . . . . . . . . . . . . . 199
Deck Inserts . . . . . . . . . . . . . . . . . . . . . . . . . 200
Components . . . . . . . . . . . . . . . . . . . . . . . . . 201
Concrete Inserts Technical Data . . . . . . . . . 202
1
1 ⁄ " FRAMING SYSTEM . . . . 203-224
4
1
1 ⁄ " Framing System Pictorial Index . . . 204-205
4

Channels . . . . . . . . . . . . . . . . . . . . . . . . 206-213
Nut Selection and Load Data . . . . . . . . . . . . 214
Unistrut Nuts . . . . . . . . . . . . . . . . . . . . . . . . 215
Channel End Caps & Closure Strips . . . . . . . 216
Fittings . . . . . . . . . . . . . . . . . . . . . . . . . 217-222
Tubing Clips . . . . . . . . . . . . . . . . . . . . . . . . . 223
Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224
13
⁄ " FRAMING SYSTEM . . . . . 225-246
16
13
⁄ " Framing System Pictorial Index . . . 226-227
16

Channels . . . . . . . . . . . . . . . . . . . . . . . . 228-232
Channel Nuts, Caps & Closures . . . . . . . . . . 233 SPECIAL METALS . . . . . . . . . 271-278
Fittings . . . . . . . . . . . . . . . . . . . . . . . . . 234-244 Special Metals Pictorial Index . . . . . . . . . . . 272
Special Applications . . . . . . . . . . . . . . . . . . . 245 Stainless Steel . . . . . . . . . . . . . . . . . . . . 273-274
Beam Clamps & Tubing Clips . . . . . . . . . . . . 246 Stainless Steel Channel Nuts . . . . . . . . . . . . . 275
Extruded Aluminum Channels . . . . . . . 276-278
FIBERGLASS SYSTEM . . . . . . 247-270

Fiberglass Pictorial Index . . . . . . . . . . . 248-249 PRIMEANGLE ................................ 279-284
Fiberglass Channel . . . . . . . . . . . . . . . . 250-255 PrimeAngle & Accessories . . . . . . . . . . 280-281
Fiberglass Channel Nuts & Accessories . . . . 256 PrimeAngle Beam Loads . . . . . . . . . . . . 282-283
Fiberglass Hardware and Accessories . 257-259 PrimeAngle Column Loads . . . . . . . . . . . . . . 284
Fittings . . . . . . . . . . . . . . . . . . . . . . . . . 260-264
Fiberglass Pipe Clamps . . . . . . . . . . . . . 265-266 INDEX . . . . . . . . . . . . . . . . . . 285-288
Fiberglass Clevis Hangers . . . . . . . . . . . . . . . 267
Subject Index . . . . . . . . . . . . . . . . . . . . 285-288
Fiberglass Beam Clamps,
Power-Rack Stanchions . . . . . . . . . . . . . . 268
Fiberglass Technical Data . . . . . . . . . . . . . . . 269
Fiberglass Sample Specifications . . . . . . . . . 270
® UNISTRUT METAL FRAMING – THE ORIGINAL STRUT SYSTEM

Featuring The Unique Weldless Connection

Hex-head bolt connects


fitting to channel as it is
threaded into spring
nut.

Chamfer in the nut eases


starting of the bolt.
Nut teeth create a
strong, vise-like grip
when tightened against
the inturned channel
edges.

Channel edges and the


nut's tapered grooves
act as guides to provide
fool-proof alignment of
connection.

Nut teeth grip the


channel's inturned
edges, tying the channel
sides together in a "box"
configuration for added
strength.

Spring allows precision


placement anywhere
along channel length,
then holds the nut in
position while the
connection is completed.

6 Unistrut – The Original Metal Framing


Unistrut Connection
THE ORIGINAL STRUT SYSTEM

Strong, Fast, Economical and Adjustable


Insert the spring nut anywhere
along the continuous slotted 1
channel. The rounded nut ends
permit easy insertion.

A 90° clockwise turn aligns the


2 grooves in the nut with the inturned
edges of the channel.

Fittings can be placed anywhere


along the channel opening,
permitting complete freedom of
adjustment. The need for drilling
holes is eliminated.

■ 100% Adjustable

■ 100% Reusable
Insert the bolt through the
3
fitting and into the spring
1
nut. (See illustration 5 for ■ No Welding
end view showing the nut in
place) ■ No Drilling

■ No Special Tools

Additional channel sections can


4
now be bolted to the fitting
already in place by following
procedure described in steps 1–3.

5
Tightening with a wrench
locks the serrated teeth of the
nut into the inturned edges of
the channel, to complete a
strong, vise-like connection.

Unistrut – The Original Metal Framing 7


® Unistrut Service Centers
THE ORIGINAL STRUT SYSTEM

Serving Design
Professionals for
Over 60 Years

Unistrut products have been


helping to build a better
world since 1924. Used exten-
sively in nuclear, industrial
and commercial construction
markets for over 75 years,
Unistrut Metal Framing has set
the standard for product
design, quality and perfor-
mance. The initial Unistrut
concept — a simple spring nut
and bolt connecting a fitting
to a continuous slotted chan-
nel — has evolved into a
comprehensive engineered
building and support system.
There is only one Unistrut distribution centers, Unistrut
Unistrut® — The Original Metal Framing System. It provides customers with total-
Metal Framing System incorporates the innovative resource capability.
product improvements that our
research and development A North American network of
group has created to give you Unistrut Service Centers
the most complete and flexible — stocking standard Unistrut
support system available. components — are located in
Backed by our worldwide principal cities to serve you
network of engineering and quickly and directly. Many
Service Centers are equipped
to design and supply drawings
for any type of metal framing
application and also offer
fabrication and installation
services.

This catalog is a comprehen-


sive presentation of Unistrut
Metal Framing components
plus technical data required by
design, specification and
construction professionals.

8 Unistrut – The Original Metal Framing


Unistrut Framing Systems
THE ORIGINAL STRUT SYSTEM

The Most Complete Metal Framing System — Three Channel-Width Options

Adjustability, demountability and reusability are engineered into each of the three Unistrut channel series.
Each series offers channels of varying depth and gage plus a complete line of fittings and accessories.

15⁄8” (41mm) width


15⁄8" width Series Channel
1 5 ⁄8 "
Designed to carry the heaviest
loads and provide the widest
variety of applications, the 15⁄8"
series has become the accepted
VARIOUS
standard for use in mechanical,
HEIGHTS electrical and general construc-
AVAILABLE
tion applications where supports
and attachments must meet the
highest strength requirements.

1
11⁄4” (32mm) width
1 ⁄4" width Series Channel
1 1⁄ 4"
A framing system designed for
medium loads, the 11⁄4" series is
especially suitable for use in the
VARIOUS
OEM, commercial and display
HEIGHTS
AVAILABLE
markets. It maintains a lightness
in scale and a clean line that
makes it aesthetically pleasing as
well as functional.

⁄ ” (21mm) width
13 16
13
⁄16" width Series Channel
A unique half-size reduction of
13
⁄16"
the 15⁄8" channel-width series, this
smaller channel size can be used
VARIOUS to carry light loads economically
HEIGHTS
AVAILABLE in applications such as instrumen-
tation, retail displays and light-
duty laboratory supports. It also
provides the flexibility found in
all Unistrut framing systems.

Unistrut – The Original Metal Framing 9


® Quality Assurance and Traceability

Product Load Testing

Product testing is an important Destructive and non-destructive data given in this catalog, and/or
Part of Unistrut’s Quality Assur- testing procedures are used to design procedures of the
ance Program. We utilize our own test for variables such as corro- American Iron & Steel Institute
testing facilities, as well as those sion, conductivity, electro-static Specification For The Design Of
of independent testing laborato- dissipation, ultra-violet resistance, Cold-Formed Steel Structural
ries, to determine design loads wind resistance, dimensional Members, 2001 Edition, it is
with proper and adequate safety accuracy, material integrity and possible to design any type of
factors. These design loads are slip resistance. structure within the capabilities
indicated, where applicable, In short, if there’s a specification of the system.
throughout the catalog. Loads are to meet, Unistrut will develop a Assemblies or connections that
based on AISI Specification For test to quantify and verify it. cannot be calculated using
The Design Of Cold-Formed Steel Using design properties of the provisions of the AISI specifica-
Structural Members, 2001 Edition. Unistrut framing members, load tions must be established by
application-specific tests.

Quality Program
Unistrut is committed to being operating procedures and quality Our drive to be the best includes
the “best” in the metal framing systems to find ways of improving not just quality products, but
industry. In order to meet this efficiency, productivity and on-time delivery and prompt
goal, Unistrut has adopted the quality. It means establishing resolution of customer needs and
philosophy of “Zero Defects and process controls and problem- concerns. At Unistrut, quality is
Continuous Improvement”. This prevention techniques to ensure number one.
means on-going reviews of our that superior quality is built into
manufacturing processes, every Unistrut product.

Traceability

UNISTRUT CHANNEL IS STAMPED WITH A


NUMERIC CODE THAT ALLOWS TRACEABILITY
TO THE ORIGIN OF THE STEEL

10 Unistrut – The Original Metal Framing


Materials and Finishes

Material

Framing Members Nuts and Bolts Fittings


Unistrut channels and continuous Unistrut nuts are made from steel Unistrut fittings, unless noted
inserts are accurately and carefully bars. After all machining otherwise, are punch-press made
cold-formed to size from low operations are complete, they are from hot rolled, pickled and oiled
carbon strip steel. One side of the thoroughly case hardened. Nuts steel plates, strip or coil, and
channel has a continuous slot with are rectangular with ends shaped conform to ASTM specifications
inturned edges. Secure attach- to permit a quarter turn clockwise A575, A576, A635 or A36. The
ments may be made to the fram- in the framing member after fitting steel also meets the
ing member with the use of insertion through the slotted physical requirement of ASTM
hardened, toothed, slotted nuts opening in the channel. Two A1011 SS GR 33. The pickling of
which engage the inturned edges. toothed grooves in the top of the the steel produces a smooth
nut engage the inturned edges of surface free from scale.
Raw steel shall conform to the the channel and, after bolting
following ASTM specifications: operations are completed, will
prevent any movement of the bolt
GAGE FINISH ASTM NO. and nut within the framing
12 GR & HG A1011 SS GR 33 member. All bolts and nuts have
PG A653 GR 33
Unified coarse screw threads.
The standard framing nut is 1⁄2"
14 GR & HG A1011 SS GR 33 and conforms to ASTM Specifica-
PG A653 GR 33 tion A1011 SS GR 33 (material
16 GR & HG A1011 SS GR 33
only). Screws conform to SAE J429
PG A653 GR 33 GR 2 (also meets and exceeds
ASTM A307).
19 GR A1008

Weights and Dimensions

Weights given for all materials are


approximate shipping weights.
All dimensions are subject to
commercial tolerance within
published specifications.

WE RESERVE THE RIGHT TO MAKE SPECIFICATION CHANGES


WITHOUT NOTICE.

WHILE EVERY EFFORT HAS BEEN MADE TO ASSURE THE ACCURACY


OF INFORMATION CONTAINED IN THIS CATALOG AT THE TIME OF
PUBLICATION, WE CANNOT ACCEPT RESPONSIBILITY FOR
INACCURACIES RESULTING FROM UNDETECTED ERRORS OR OMISSIONS.

THE BLUE COLOR USED ON UNISTRUT COMPONENTS ILLUSTRATED


IN THIS CATALOG IS FOR GRAPHIC ENHANCEMENT ONLY, AND DOES
NOT REPRESENT ACTUAL PRODUCT COLOR.

Unistrut – The Original Metal Framing 11


® Materials and Finishes

Perma-Green® III
The performance of Unistrut’s Perma-Green III far common acidic atmospheres, solvents and alkalis.
exceeds that of conventional finishes. And compared Just as important, Perma-Green III is the result of an
to competitive “high-performance” coatings, Perma- environmentally neutral process that virtually
Green III provides superior resistance to chalking, eliminates the toxic metals commonly found in
checking and fading and is far less vulnerable to competitive paint-based finishes.

TANK 1 TANK 2 TANK 3 TANK 4 TANK 5 TANK 6 TANK 7 TANK 8


First stage hot Second stage Channel is rinsed Conditioning Channel is Channel is rinsed Sealer is applied. First stage
alkaline cleaning hot alkaline with clean water rinse. phosphated to to remove deionizer water
of channel. cleaning of to remove produce a zinc excess rinse to remove
channel. cleaning phosphate phosphate excess sealer.
solution. coating. solution.

TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 OVEN


Second stage Final deionizer Electro-deposition Post rinse spray. Post rinse dip Post rinse spray. Virgin deionized The cure process
deionized water water rinse. tank applies the tray. water halo rinse. dries the channel
rinse to prepare acrylic Perma- and cross links the
channel for Green III to all acrylic thermoset
E-Coating. surfaces. resins at 375° F.

Unistrut Perma-Green III is a thoroughly cleaned and coated with


E-Coat factory applied, electro- an zinc phosphate conversion
Sealer
deposition acrylic coating with coating. Unistrut’s unique, custom-
Zinc Phosphate superior rust protection and designed “prep” process consists of
fade-resistance. The acrylic ten separate steps, the most thorough
coating is a proprietary formula- in the industry. The cleaning,
tion and is essentially “heavy- phosphating and electrodeposition
metal” free. The electrodeposi- coating processes are continuous
tion coating process provides a and, unlike “batch” processing, result
smooth, hard, durable surface in a uniform coating quality.
which is completely cured. This
inhibits introduction of airborne Production samples are tested on a
Prepared contaminates which can continuous basis for corrosion
Steel adversely affect sensitive resistance. Unistrut Perma-Green III
manufacturing environments. exceeds 400 hours salt spray
(1⁄8" creep from scribe) when tested
Before the electrodeposition to ASTM B117. Unscribed samples
acrylic coating is applied, exceed 600 hours salt spray. (6% red
Unistrut channel and fittings are rust)

12 Unistrut – The Original Metal Framing


Materials and Finishes

Zinc Coating Electroplated Zinc–


PERMA-GREEN® III (GR) ASTM B633, Type III SC1
TECHNICAL DATA Unistrut products are available in
three types of zinc coatings: In the electroplating process, the
STEEL SUBSTRATE PREPARATION • Electroplated part to be zinc coated is immersed
Ten stage continuous cleaning, • Pregalvanized in a solution of zinc ions. An electric
phosphate process. • Hot Dip Galvanized. current causes the zinc to be
Substrate after “prep”: sealed zinc deposited on the part.
phosphate conversion coating. Zinc coatings offer two types of
protection: Zinc plated parts typically have a zinc
coating of .2 to .5 MIL and are
COATING • Barrier: The zinc coating protects recommended for dry indoor use.
Thermoset acrylic the steel substrate from direct
Color: contact with the environment. Pregalvanized Zinc-
Federal Highway Green
• Sacrificial: The zinc coating will
ASTM A653
Color Tolerance Chart
PR Color No. 4 protect scratches, cut edges, etc. Pregalvanized steel is zinc coated by a
through an anodic sacrificial hot dip process. Steel strip from a
Hardness: 2H.
process. coil is fed through a continuous zinc
Coating Process: coater which cleans, fluxes and coats
Cathodic Electrodeposition. The service life of zinc coating is the steel with molten zinc. After
directly related to the zinc coating cooling, the steel is recoiled.
PERFORMANCE thicknessas shown below.
Salt Spray: The pregalvanized zinc coating
Scribed: exceeds 400 hours conforms to a G-90 thickness
per ASTM B117. (1⁄8" creep) designation per ASTM A653.
Unscribed: exceeds 600 hours COMPARISON OF ZINC The zinc thickness is .75 MIL or
per ASTM B117. (6% red rust) GALVANIZED FINISHES .45 oz./sq. ft. of surface area.
Chalk: Finish Zinc Thickness This coating is offered on Unistrut
Nominal at 1,000 hours per
weatherometer G-23 test. Hot Dip Galvanized 2.6 MIL channel and tubing and is a well-
Pregalvanized .75 MIL proven, time-tested performer for
Checking:
None at 1,000 hours per Electro-Galvanized .2 to .5 MIL indoor and outdoor applications. For
weatherometer G-23 test. Perma-Gold .5 MIL severe corrosion applications, hot dip
galvanizing, as described below, is a
Fade: As shown in the graph, when the zinc good alternative.
Less than 50% compared to
coating is double, the service life is
standard epoxy E.C. coatings. HOT DIP GALVANIZED (HG)
double under most conditions.
ASTM A123 OR A153
ENVIRONMENTAL ISSUES
In hot dip galvanizing, the finished
Formulated as a “heavy metal”-
free coating (trace elements Life of Protection vs. Thickness of Zinc part is immersed in a bath of molten
only). and Type of Atmosphere zinc. This method results in com-
plete zinc coverage and a thicker
Outgassing in service: essentially * Service Life is defined as the time to 5% rusting of the steel surface

none at 350°F for 24 hours. 80


11 21 32 43 54 65 75 86 97 108 118 129 coating than pregalvanized or plated
zinc.
70 L
RA
RU
60
The zinc coating is typically 2.6 MIL
Service Life, Years*

E
RIN
MA INE
or 1.5 oz./sq. ft. of surface area.
AL
PLAIN (PL) 50
OP
I
TR RATE
C M A R

40 TEM
PE
R BAN L
This is the coating of choice for
U
Plain finish designation means that SUB USTRI
ND
A
applications where severe corrosion
E LY I
the channel retains the oiled surface 30
MO
DERA
T
is a design factor.
applied to the raw steel during the 20 Y IND
USTR
IAL
HEAV
rolling process. The fittings have the SPECIAL COATING
10
original oiled surface of the bar-stock When specific applications require
material. Oz. of Zinc/Sq. Ft. of Surface other than standard available finishes,
.25 .50 .75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00
Thickness of Zinc in Mils special finishes can be supplied per
0.4 0.8 1.3 1.7 2.1 2.6 3.0 3.4 3.8 4.2 4.7 5.1
customer requirements.

Unistrut – The Original Metal Framing 13


® Design Fundamentals

Beams
Beams are structural members loaded at SUPPORT CONDITIONS - The stiffness of the beam’s cross-sectional
right angles (perpendicular) to their CONTINUOUS BEAM shape is measured by its “Moment Of
length. Most beams are horizontal and Inertia” or "I". The larger a beam’s "I", the
subjected to gravity or vertical loads, e.g. stiffer it is and the less it will deflect. A
a shelf support. However a vertical beam’s "I" can change for each major
member can act as a beam under certain axis. The "I" of both major axes (I 1-1 and
conditions, such as a curtain wall mullion I 2-2) are provided.
subjected to wind loading. The bending
The stiffness of a beam’s material is
moment developed in a beam is depen-
Any simple beam that is supported at one measured by its “Modulus of Elasticity” or
dent on:
or more intermediate points is a continu- "E". The larger a material’s "E", the stiffer
ous beam. A mezzanine joist that passes it is and the less it deflects. For example,
(a) the amount of load applied,
over three or more columns is an steel is about three times stiffer than
(b) the type of loading applied, and
example of a continuous beam. aluminum and as a result, deflects only
(c) the support conditions.
one-third as much. Do not confuse
BEAM LOADING - POINT LOAD SUPPORT CONDITIONS - stiffness with strength. Two materials
FIXED-END BEAM may have identical strengths yet still have
different "E’s". A high-strength aluminum
may be as strong as steel and still deflect
three times as much.
The load charts and tables give calculated
deflections for the loads shown. In many
A load concentrated onto a very small cases, a final design will be determined
length of the beam is a point load. by the maximum deflection, not the
Supports that prevent the beam from maximum load.
BEAM LOADING - UNIFORM LOAD rotating into a natural deflected curve
produce a fixed-end beam. A welded end BENDING MOMENT
connection to very rigid support pro- Is it strong enough? This is the final
duces a fixed-end beam. consideration for any beam. A beam
must not only hold up the anticipated
SUPPORT CONDITIONS -
loads, but must also have sufficient
CANTILEVER BEAM additional capacity to safely hold unfore-
A load spread evenly over a relatively seen variations in applied loads and
long length of the beam is a uniform load. material strengths. This additional
capacity is called a safety factor and is
Point and uniform loads can be placed on usually regulated by the various design
a beam in any combination. A series of codes and standards. A beam’s strength
point loads can approximate a uniform A cantilever beam is a fixed-end beam is usually measured by an allowable
loading. The load charts and tables are that is supported at one end only, while bending moment or an allowable stress.
based on a uniform load unless identified the other end is unsupported. Unistrut The traditional approach is the allowable
otherwise. brackets are examples of cantilever stress method, where a beam is deter-
beams. mined to have a maximum allowable
SUPPORT CONDITIONS - SIMPLE BEAM
stress (in pounds per square inch) which
DEFLECTION is not to be exceeded.
The approach of the current AISI
“Specification For The Design Of Cold-
Formed Steel Structural Members” is to
use a maximum allowable bending
moment (in inch-pounds) which is not to
A simple beam has supports that prevent
be exceeded. Bending moment divided
movement left and right, or up and All beams deflect under load. The by a beam’s section modulus or "S" equals
down, but do not restrain the beam from amount of deflection is dependent on stress.
rotating at the supports into a natural
deflected curve. Most Unistrut Metal (a) the amount of load,
Framing connections produce simple (b) the support conditions,
beams. The load charts and tables are (c) the stiffness of the beam’s cross-
based on simple beams unless identified sectional shape, and
otherwise. (d) the stiffness of the beam material.

14 Unistrut – The Original Metal Framing


Design Fundamental

Columns
Columns are structural members that are SUPPORT CONDITIONS - CROSS-SECTIONAL SHAPE
loaded parallel to their length. Most FIXED TOP – FIXED BOTTOM The cross-sectional shape of a column
columns are vertical and are used to
Both ends are member determines the value of its
carry loads from a higher level to a lower
restrained against “Radius of Gyration” or "r". In general, a
level. However any member subjected
rotation and lateral member with a large "r" makes a better
to compression loads, such as a diagonal
movement column than a member with a small "r".
or prop brace, is a column.
(translation). Each axis of a column has a different "r".
A column fails by “buckling”, which is a K = 0.65 Typically the axis with the smallest "r"
sudden loss of straightness and subse- determines the final design.
quent collapse. Allowable column load
is dependent on: BOLT TORQUE
(a) the length of column, Bolt torque values are given to ensure the
(b) the type of loading, proper connection between Unistrut
(c) the support conditions, and Metal Framing components. It is impor-
(d) the column’s cross-sectional shape SUPPORT CONDITIONS - tant to understand that there is a direct,
and material. PINNED TOP – FIXED BOTTOM but not necessarily consistent, relation-
ship between bolt torque and tension in
COLUMN LENGTH The top is restrained the bolt. Too much tension in the bolt
against lateral move- can cause it to break or crush the
The column length is measured from
ment (translation) but is component parts. Too little tension in
braced point to braced point. A braced
allowed to rotate. The the bolt can prevent the connection from
point is where the column is restrained
bottom is restrained developing its full load capacity. The
from lateral movement (translation) in all
against rotation and torque values given have been developed
directions. K = 0.80
lateral movement. over many years of experience and
COLUMN LOADING – This is a common testing.
CONCENTRIC LOADING support condition and
Recommended Bolt Torque
is used to construct the
Loads applied to the center of gravity of Bolt 1
⁄4" 5
⁄16" 3
⁄8" 1
⁄2" 5
⁄8" 3
⁄4"
allowable column load
the column cross-section are considered
applied at the Slot Face Size 20 18 16 13 11 10
concentric. A beam that passes over and
tables. Foot
rests on the top of a column is an 6 11 19 50 100 125
example of concentric loading. Lbs.
SUPPORT CONDITIONS -
PINNED TOP – PINNED BOTTOM N•m 8 15 25 70 135 170
COLUMN LOADING –
ECCENTRIC LOADING These are based on using a properly
Both ends are calibrated torque wrench with a clean dry
Any load which is not concentric is
restrained against (non-lubricated) Unistrut fitting, bolt and
eccentric. The amount of eccentricity
lateral movement nut. A lubricated bolt or nut can cause
(in inches) has a major effect on the load-
(translation) but, are extremely high tension in the connection
carrying capacity of any particular
allowed to rotate. and may lead to bolt failure. It must be
column. A load that is transmitted to a K = 1.0
Unistrut Metal Framing column using a noted that the accuracy of commercial
standard fitting bolted to the slot face is torque wrenches varies widely and it is
considered eccentric. the responsibility of the installer to
ensure that proper bolt torque has been
The load tables give allowable loads for achieved.
both concentric (loaded at C.G.) and
certain eccentric (loaded at slot face)
loading. Allowable loads for other SUPPORT CONDITIONS -
eccentric loading must be determined by FIXED / FREE TOP – FIXED BOTTOM
a qualified design professional.

SUPPORT CONDITIONS The top is restrained


against rotation but is
Based on the support conditions, an allowed to move
appropriate "K" value is selected. This laterally. The bottom is
“K” value, which mathematically K = 1.2
restrained against
describes the column end conditions, is rotation and lateral
used in the column design equations. movement (translation).
The most common support condition
combinations are as follows:

Unistrut – The Original Metal Framing 15


® Conversion Factors

Unit Conversions

English To Metric Metric to English


To Convert From To Multiply By To Convert From To Multiply By
Length Length
Inch [in] Millimeter [mm] 25.400 000 Millimeter [mm] Inch [in] 0.039 370
Foot [ft] Meter [m] 0.304 800 Meter [m] Foot [ft] 3.280 840
Yard [yd] Meter [m] 0.914 400 Meter [m] Yard [yd] 1.093 613
Mile [mi] (U.S. Statute) Kilometer [km] 1.609 347 Kilometer [km] Mile [mi] (U.S. Statute) 0.621 370
Area Area
Square Inch [in ] 2 2
Square Millimeter [mm ] 645.16 Square Millimeter [mm2] Square Inch [in2] 0.001550
Square Foot [ft2] Square Meter [m2] 0.092 903 Square Meter [m2] Square Foot [ft2] 10.763 915
Square Yard [yd2] Sqare Meter [m2] 0.836 127 Sqare Meter [m2] Square Yard [yd2] 1.195 991
Square Mile [mi2] (U.S. Statute) Square Kilometer [km2] 2.589 998 Square Kilometer [km2] Square Mile [mi2](U.S. Statute) 0.386 101
Acre Square Meter [m2] 4046.873 Square Meter [m2] Acre 0.000 247
Acre Hectare 0.404 687 Hectare Acre 2.471 046
Volume Volume
Cubic Inch [in3] Cubic Millimeter [mm3] 16387.06 Cubic Millimeter [mm3] Cubic Inch [in3] 0.000061
Cubic Foot [ft3] Cubic Meter [m3] 0.028 317 Cubic Meter [m3] Cubic Foot [ft3] 35.314 662
Cubic Yard [yd3] Cubic Meter [m3] 0.764 555 Cubic Meter [m3] Cubic Yard [yd3] 1.307 950
Gallon [gal] (U.S. Liquid) Litre [l] 3.785 412 Litre [l] Gallon [gal] (U.S. Liquid) 0.264 172
Quart [qt] (U.S. Liquid) Litre [l] 0.946 353 Litre [l] Quart [qt] (U.S. Liquid) 1.056 688
Mass Mass
Ounce (Avoirdupois) [oz] Gram [g] 28.349 520 Gram [g] Ounce (Avoirdupois) [oz] 0.035 274
Pound (Avoirdupois) [lb] Kilogram [kg] 0.453 592 Kilogram [kg] Pound (Avoirdupois) [lb] 2.204 624
Short Ton Kilogram [kg] 907.185 Kilogram [kg] Short Ton 0.00110
Force Force
Ounce-Force Newton [N] 0.278 014 Newton [N] Ounce-Force 3.596 941
Pound-Force [lbf] Newton [N] 4.448 222 Newton [N] Pound-Force [lbf] 0.224 809
Bending Moment Bending Moment
Pound-Force-Inch [lbf-in] Netwon-Meter [N-m] 0.112 985 Netwon-Meter [N-m] Pound-Force-Inch [lbf-in] 8.850 732
Pound-Force-Foot [lbf-ft] Newton-Meter [N-m] 1.355 818 Newton-Meter [N-m] Pound-Force-Foot [lbf-ft] 0.737 562
Pressure, Stress Pressure, Stress
Pound-Force per Kilopascal [kPa] 6.894 757 Kilopascal [kPa] Pound-Force per 0.145 038
Square Inch [lbf/in2] Square Inch [lbf/in2]
Foot of Water (39.2 F) Kilopascal [kPa] 2.988 980 Kilopascal [kPa] Foot of Water (39.2 F) 0.334 562
Inch of Mercury (32 F) Kilopascal [kPa] 3.386 380 Kilopascal [kPa] Inch of Mercury (32 F) 0.295 301
Energy, Work, Heat Energy, Work, Heat
Foot-Pound-Force [ft-lbf] Joule [J] 1.355 818 Joule [J] Foot-Pound-Force [ft-lbf] 0.737 562
British Thermal Unit [Btu] Joule [J] 1055.056 Joule [J] British Thermal Unit [Btu] 0.000948
Calorie [cal] Joule [J] 4.186 800 Joule [J] Calorie [cal] 0.238 846
Kilowatt Hour [kW-h] Joule [J] 3,600,000 Joule [J] Kilowatt Hour [kW-h] 2.78-7
Power Power
Foot-Pound-Force Watt [W] 1.355 818 Watt [W] Foot-Pound-Force 0.737 562
/Second [ft-lbs/s] /Second [ft-lbs/s]
British Thermal Unit Watt [W] 0.293 071 Watt [W] British Thermal Unit 3.412 142
/Hour [Btu/h] /Hour [Btu/h]
Horsepower [hp] (550 Ft. Lbf/s) Kilowatt [kW] 0.745 700 Kilowatt [kW] Horsepower (550 Ft. Lbf/s) [hp]1.341 022
Angle Angle
Degree Radian [rad] 0.017 453 Radian [rad] Degree 57.295 788
Temperature Temperature
Degree Fahrenheit [°F] Degree Celsius [°C] (F° -32)/1.8 Degree Celsius [°C] Degree Fahrenheit [°F] 1.8xC°+32

16 Unistrut – The Original Metal Framing


Reference Tables and Data
FORMULAE ON COMMON BEAM LOADINGS

Beam Support Conditions

Cantilever Beams
P P
a b
V max. = P V max. = W V max. = P
L L WL L
M max. = PL M max. = M max. = Pb
2
3 3 2
max. = PL max. = WL max. = Pb (3L-b)
3EI V 8EI V 6EI
V

M M M

Cantilever Beams
P P
L a b
2
P W
R= R= R1= Pb
2 2 L
L P L W L Pa
R R V max. = R R V max. = R1 R2 R2 =
2 2 L
PL WL
V M max. = V M max. = V V max. = Pa
4 8 L
PL 3 5WL 3 Pab
max. = max. = M max. =
48EI 384EI L
Pab(a+2b) 3a(a+2b)
M M M max. =
27EIL

Cantilever Beams
P P
L 2
2 a b R1= Pb3 (a+2L)
5P 3W 2L
R1= R1=
16 8
L 11P L 5W L
R1 V max. = V max. = Pa 2 2
16 R1 8 R1 R2 R2= 3 (3L -a )
2L
V 3PL V WL
M max. = M max. = V
16 3L 8 M at point of load = R1a
8
max. at x = 0.447L max. at x = 0.4215L
M at fixed end = Pab (a+L)
M PL3 M max. = WL
3
M 2L3
max. = 0.009317 3L 185EI
EI 4

Cantilever Beams
P P
L a b 2
2
P W R1= Pb3 (3a+b)
V max. = V max. = L
2 2
L PL L WL L 2
M max. = M max. = R2= Pa3 (a+3b)
8 12 R1 R2 L
PL 3 WL 3
V max. = V max. = V
192EI 384EI 2
M1 = Pab
L2
2
M2 = Pa2 b
L
M M M1 M2

R – Reaction W – Total Uniform Load – Deflection


M – Moment V – Shear E – Modulus of Elasticity
P – Concentrated Load L – Length I – Moment of Inertia

Unistrut – The Original Metal Framing 17


® Reference Tables and Data

CONVERSION FACTORS FOR BEAMS WITH VARIOUS STATIC LOADING CONDITIONS


All Beam Load tables are for single-span (simple) beams supported at the ends. These can be used in the majority of
the cases. However, there are times when it is necessary to know what happens with other loading and support
conditions. Some common arrangements are shown below. Simply multiply the values from the Beam Load tables by
factors given below

Load Deflection
Load and Support Condition Factor Factor

1. Simple Beam,
1.00 1.00
Uniform Load SPAN

2. Simple Beam,
.50 .80
Concentrated Load at Center

3. Simple Beam,
1.00 1.10
Two Equal Concentrated Loadcs at 1/4 pts

4. Beam Fixed at Both Ends,


1.50 .30
Uniform Load

5. Beam Fixed at Both Ends,


1.00 .40
Concentrated Load at Center

6. Cantilever Beam,
.25 2.40
Uniform Load

7. Cantilever Beam,
.12 3.20
Concentrated Load at End

8. Continuous Beam, Two Equal Spans,


1.30 .92
Uniform Load on One Span SPAN SPAN

9. Continuous Beam, Two Equal Spans,


1.00 .42
Uniform Load on Both Ends

10. Continuous Beam, Two Equal Spans,


.62 .71
Concentrated Load at Center of One Span

11. Continuous Beam, Two Equal Spans,


.67 .48
Concentrated Load at Center of Each Span

EXAMPLE I: EXAMPLE II
Determine load and deflection of a 5' -0" 5' -0" Determine load and deflection of a P 5500
P 1000 beam continuous over one cantilever beam with a concentrated load on
3' -0"
support and loaded uniformly on one span. the end.

SOLUTION: SOLUTION:
A. From load table for P1000 on page 26 load for a 5'-0" span is A. From load table P5500 on page 57 load for a 3'-0" span is
680# and deflection is .35". 2180# and deflection is .09".
B. Multiply by factors from Table above. B. Multiply by factors from Table above.
Load = 680# x 1.30 = 884# Load = 2180# x .12 = 262#
Deflection = .35" x .92 = .32" Deflection = .09" x 3.20 = .29"

18 Unistrut – The Original Metal Framing


Guide Specification

PART I - GENERAL
1.01 SCOPE OF WORK 2. Submit all shop/assembly ance Chart PR Color No. 4.
drawings necessary to com- Finish to withstand minimum
A. Provide all Unistrut Metal Framing 400 hours salt spray when tested
pletely install the Strut System
material, fittings and related in accordance with ASTM B117.
in compliance with
accessories (Strut System) as
the Contract Drawings.
indicated on the Contract Drawings. 2. ELECTRO-GALVANIZED (EG)
3. Submit all pertinent manufactur-
B. Provide all labor, supervision, Electrolytically zinc coated per
ers published data.
engineering, and fabrication ASTM B 633 Type III SC 1
required for installation of the Strut 1.04 PRODUCT DELIVERY,
System in accordance with the STORAGE, AND HANDLING 3. PRE-GALVANIZED (PG)
Contract Drawings and as specified Zinc coated by hot-dipped
A. All material is to be delivered to
herein. process prior to roll forming. The
the work site in original factory
C. Related work specified elsewhere. zinc weight shall be G90
packaging to avoid damage to the
1.02 QUALITY ASSURANCE finish. conforming to ASTM A 653.
B. Upon delivery to the work site,
A. Manufacturer’s qualifications: 4. HOT-DIPPED GALVANIZED (HG)
all components shall be protected
1. The manufacturer shall not Zinc coated after all manufactur-
from the elements by a shelter or
have had less than 10 year’s ing operations are complete.
other covering.
experience in manufacturing Coating shall conform to ASTM A
Strut Systems. 1.05 GUARANTEE 123 or A 153.
2. The manufacturer must certify
A. Separate guarantees shall be issued
in writing all components 5. SPECIAL COATING / MATERIAL
from the erector and manufacturer,
supplied have been produced in (Describe as applicable)
valid for a period of 1 year, against
accordance with an established
any defects that may arise from the
quality assurance program. PART 3 - EXECUTION
installation or manufacture of the
B. Installer’s qualifications:
Strut System components. 3.01 EXAMINATION
1. Installer must be a Unistrut
trained manufacturer’s autho- PART 2 - PRODUCTS A. The installer shall inspect the work
rized representative/installer area prior to installation. If work
with not less than 5 years 2.01 ACCEPTABLE MANUFACTURERS area conditions are unsatisfactory,
experience in the installation of A. All Strut System components shall installation shall not proceed until
Strut Systems of this size and be as manufactured by UNISTRUT satisfactory corrections are
conformation. CORPORATION or approved equal completed.
2. All Strut System components as determined by the Architect or
must be supplied by a single Engineer of record in writing 10 3.02 INSTALLATION
manufacturer. days prior to bid date. A. Installation shall be accomplished by a
C. Standards: fully trained manufacturer autho-
1. Work shall meet the require- 2.02 MATERIALS rized installer.
ments of the following A. All channel members shall be B. Set Strut System components into
standards: fabricated from structural grade final position true to line, level and
a. Federal, State and Local steel conforming to one of the plumb, in accordance with
codes. following ASTM specifications: approved shop drawings.
b. American Iron and Steel A 1011 SS GR 33, A 653 GR 33. C. Anchor material firmly in place.
Institute (AISI) Specification B. All fittings shall be fabricated from Tighten all connections to their
for the Design of Cold- steel conforming to one of the recommended torques.
Formed Steel Structural following ASTM specifications:
Members 2001 Edition. A 575, A 576, A 36 or A 635. 3.03 CLEANUP
c. American Society for Testing C. Substitutions A. Upon completion of this section of
And Materials (ASTM). Any substitutions of product or work, remove all protective wraps
manufacturer must be approved in and debris. Repair any damage due
1.03 SUBMITTALS writing ten days prior to bid date, to installation of this section of
A. Structural Calculations and Shop by Architect or Engineer of record. work.
Drawings
1. Submit structural calculations 2.03 FINISHES 3.04 PROTECTION
for approval by the project A. Strut System components shall be A. During installation, it shall be the
engineer. Calculations may finished in accordance with one of responsibility of the installer to
include, but are not limited to: the following standards: protect this work from damage.
B. Upon completion of this scope
a. Description of design
1. PERMA-GREEN® III (GR) of work, it shall become the
criteria.
Rust inhibiting acrylic enamel responsibility of the general
b. Stress and deflection
paint applied by electro- contractor to protect this work
analysis.
deposition, after cleaning and from damage during the remainder
c. Selection of Unistrut framing
phosphating, and thoroughly of construction on the project and
members, fittings, and
baked. Color is per Federal until substantial completion.
accessories.
Highway Green, Color Toler-

Unistrut – The Original Metal Framing 19


® New Products

P3001 T P3301 T P4101 T

See Page 40 See Page 43 See Page 50

P5501 T Slot Adapter™ Swiftgrip

See Page 56 See Page 84 See Page 123

P2867B P2868B P3088

See Page 130 See Page 131 See Page 133

P1354A SPF® 100 SPF® 200

See Page 138 See Page 140 See Page 141

SPF® 300 SPF® 400 LS 410

See Page 142 See Page 143 See Page 144

LS 500 CUSH–A–THERM™ CUSH–A–GRIP®

See Page 144 See Page 157 See Page 157

UniPier™ UniPier™ Trapeze DECK INSERT

See Page 163 See Page 163 See Page 200

20 Unistrut – The Original Metal Framing


®
15⁄8" CHANNEL
Channel Selection Chart ................................... 24
P1000 (12 Gauge) ............................................... 25
P1100 (14 Gauge) ............................................... 32

P2000 (16 Gauge) ............................................... 36


P3000 (12 Gauge) ............................................... 40
P3300 (12 Gauge) ............................................... 43

P4000 (16 Gauge) ............................................... 46


P4100 (14 Gauge) ............................................... 50
P5000 (12 Gauge) ............................................... 53

P5500 (12 Gauge) ............................................... 56


Closure Strips ..................................................... 59
End Caps and Frame Caps ................................ 60

MATERIAL STANDARD LENGTHS


Unistrut channels are accurately and carefully cold Standard lengths are 10 feet (3.05m) and 20 feet (6.10m).
formed to size from low-carbon strip steel. Tolerances are +1⁄8" (3.2 mm) to +1⁄2" (12.7 mm) to allow
for cutting. Special lengths are available for a small
All spot-welded combination members, except P1001T, cutting charge with a tolerance of ± 1⁄8" (3.2mm).
are welded 3" (76 mm) maximum on center.

STEEL: PLAIN CURVED CHANNEL


12 Ga. (2.7 mm), 14 Ga.(1.9 mm) and 16 Ga. (1.5 mm) Many Unistrut 15⁄8" (41mm) channel sections are available
ASTM A1011 SS GR 33. as curved pieces in both single and combination styles.
Contact your local Unistrut Service Center or Unistrut
STEEL: PRE-GALVANIZED Corporation for ordering information.
12 Ga. (2.7 mm), 14 Ga. (1.9 mm) and 16 Ga. (1.5mm)
ASTM A653 GR 33. LOAD DATA
For other materials, see Special Metals or Fiberglass
All beam and column load data pertains to carbon steel
sections.
and stainless steel channels. Load tables and charts are
constructed to be in accordance with the SPECIFICA-
FINISHES TION FOR THE DESIGN OF COLD-FORMED STEEL
All channels are available in: STRUCTURAL MEMBERS 2001 EDITION published by the
• Perma Green II (GR). AMERICAN IRON AND STEEL INSTITUTE.
• Pre-galvanized (PG), conforming to ASTM A653 G90.
• Hot-dipped galvanized (HG), conforming to Type Safety Factor Safety Factor
ASTM A123. of Load to Yield Strength to Ultimate Strength
• Plain (PL). Beam Loads 1.67 2.0
Column Load 1.80 2.2
DIMENSIONS
Imperial dimensions are illustrated in inches. Metric
dimensions are shown in millimeters and rounded to one
decimal place.

21
® Channel Pictorial Index

P1000 Series (12 gauge)


Channel
15⁄8"
Telestrut
System
Hardware
Nuts &

P1000 P1001 - Pg 25 P1001A P1001B P1001C P1001 3 P1001 A3 P1001 B3 P1004A


Pg 25 P1001T - Pg 28 Pg 28 Pg 28 Pg 28 Pg 29 Pg 29 Pg 29 Pg 29
General
Fittings

P1001 C3 P1001 D3 P1001 C41 P1003


Pg 29 Pg 29 Pg 29 Pg 29
Pipe/Conduit
Supports

P1100 Series (14 gauge)


Electrical
Fittings

P1100 P1101 P1101A P1101B


Pg 32 Pg 33 P1101C
Pg 32 Pg 33
Pg 33
Concrete
Inserts

P2000 Series (16 gauge)


11⁄4" Framing
System

P2000 P2001 P2001A P2001B P2001C


Pg 36 Pg 36 Pg 37 Pg 37 Pg 37
⁄16" Framing
System

P3000 Series (12 gauge) P3300 Series (12 gauge) P4100 Series (14 gauge)
13
Fiberglass
System

P4100 P4101
P3300 P3301 Pg 50 Pg 50
P3000 P3001
Pg 43 Pg 43
Pg 40 Pg 40
Special
Metals

P4000 Series (16 gauge)


PrimeAngle
System

P4000 P4001 P4003 P4004


Pg 46 Pg 46 Pg 47 Pg 47
Product
Index

22 15⁄8" Framing System


Channel Pictorial Index

P5000 Series (12 gauge) P5500 Series (12 gauge) P9000 Series (12 gauge)

Channel
15⁄8"
Telestrut Channel

Telestrut
System
P5000 P5001 P5500 P5501
Pg 53 Pg 53 Pg 56 Pg 56
P9200 P9000

Hardware
Nuts &
Pg 67 Pg 67

General
Fittings
15⁄8" Channel Closure Strips End Caps and Frame Caps

Pipe/Conduit
Supports
P1184 P1184P P3184 P2860 Series P2859
Pg 59 Pg 59 Pg 59 Pg 60 Pg 60

Electrical
Fittings
P1280 P1280 A, P2280 A P1180, P2280
P3184P P3184F P3712P Pg 60 Pg 60 P4280, P5280, P5580
Pg 59 Pg 59 Pg 59 Pg 60

Concrete
Inserts
Alternate Framing Systems
A1000 Series (14 gauge) – 11⁄4" Channel

11⁄4" Framing
System
A1000 A1001 A1001A A1001B A1001C
Pg 206 Pg 206 Pg 206 Pg 206 Pg 206

Framing
System
A3300 Series (14 gauge) A4000 Series (19 gauge) A5000 Series (14 gauge)
11⁄4" Channel 11⁄4" Channel 11⁄4" Channel

13⁄16"
Fiberglass
System
A5000
Pg 213

A3300 A3301 A4000 A4001


Pg 209 Pg 209 Pg 211 Pg 211
Special
Metals

P6000 Series (19 gauge) – 13⁄16" Channel P7000 Series (19 gauge)
13
⁄16" Channel
PrimeAngle
System

P7000 P7001
P6000 P6001 P6001A P6001B P6001C Pg 231 Pg 231
Product
Index

Pg 228 Pg 228 Pg 228 Pg 228 Pg 228

Combinations not shown in catalog are available on special order. Consult factory for details.
15⁄8" Framing System 23
® Channel Selection

Channel Selection Chart


Channel
15⁄8"

Channel Dimensions Material & Thickness Hole Pattern Styles


Width Height
Telestrut

Stainless
System

Steel Alum.
Steel

Width Height Steel Stainless Alum. HS T KO SL DS H3


In (mm) In (mm) In (mm) ............................ Steel Only ..........................
Hardware

Channel gauge gauge


Nuts &

P1000 15⁄8 15⁄8 12 ga 12 ga 0.109 ■ ■ ■ ■ ■ ■


41 41 2.8
P1100 15⁄8 15⁄8 14 ga 14 ga — ■ ■ ■ ■ – –
41 41
General

■ ■ ■ ■
Fittings

P2000 15⁄8 15⁄8 16 ga — — – –


41 41
P3000 15⁄8 13⁄8 12 ga — — ■ ■ ■ ■ – –
41 35
P3300 15⁄8 7
⁄8 12 ga 12 ga — ■ ■ – ■ – –
Pipe/Conduit

41 22
Supports

P4000 15⁄8 13
⁄16 16 ga 16 ga 0.078 ■ ■ – ■ – –
41 21 2.0
P4100 15⁄8 13
⁄16 14 ga — — ■ ■ – ■ – –
41 21
P5000 15⁄8 31⁄4 12 ga — — ■ ■ ■ ■ – –
Electrical

41 83
Fittings

P5500 15⁄8 27⁄16 12 ga — 0.109 ■ ■ ■ ■ – –


41 62 2.8

Channels & Combinations in Descending Order of Strength


Concrete
Inserts

Area Weight I s Allow. Moment Area Weight I s Allow. Moment


Channel In2 (cm2) lbs/ft (kg/m) In4 (cm4) In3(cm3) In-lbs (N•m) Channel In2 (cm2) lbs/ft (kg/m) In4 (cm4) In3(cm3) In-lbs (N•m)
P5001 1.793 6.10 6.227 1.916 48,180 P1100 0.418 1.42 0.145 0.162 4,060
11.57 9.1 259.2 31.4 5,440 2.69 2.1 6.0 2.6 460
11⁄4" Framing

P1004A 1.965 6.68 4.068 1.669 41,980 P3000 0.500 1.70 0.120 0.153 3,850
System

12.68 9.9 169.3 27.4 4,740 3.23 2.5 5.0 2.5 430
P5501 1.452 4.94 2.805 1.151 28,940 P4101 0.579 1.97 0.117 0.143 3,610
9.37 7.3 116.8 18.9 3,270 3.74 2.9 4.9 2.4 410
P1001C41 2.221 7.55 1.856 1.142 28,720 P2000 0.342 1.16 0.125 0.140 3,520
14.33 11.2 77.2 18.7 3,250 2.21 1.7 5.2 2.3 400
P5000 0.897 3.05 1.098 0.627 15,770 P4001 0.478 1.66 0.104 0.128 3,210
⁄16" Framing

5.78 4.5 45.7 10.3 1,780 3.14 2.5 4.3 2.1 360
System

P1001 1.111 3.78 0.928 0.571 14,360 A3301 0.459 1.56 0.077 0.103 2,590
7.16 5.6 38.6 9.4 1,620 2.96 2.3 3.2 1.7 290
P1101 0.835 2.84 0.733 0.451 11,340 A1000 0.305 1.04 0.061 0.086 2,170
13

5.39 4.2 30.5 7.4 1,280 1.96 1.5 2.5 1.4 250
P3001 1.000 3.40 0.591 0.430 10,810 P3300 0.395 1.34 0.037 0.072 1,800
Fiberglass

6.45 5.1 24.6 7.0 1,220 2.55 2.0 1.5 1.2 200
System

P5500 0.726 2.47 0.522 0.390 9,820 A4001 0.264 0.90 0.037 0.058 1,470
4.68 3.7 21.7 6.4 1,110 1.70 1.3 1.5 1.0 170
P2001 0.684 2.32 0.618 0.381 9,570 P6001 0.213 0.73 0.045 0.055 1,400
4.41 3.5 25.7 6.2 1,080 1.38 1.1 1.9 0.9 160
P9200 0.489 2.23 0.279 0.297 7,480 P4100 0.290 0.98 0.026 0.054 1,360
Special
Metals

3.16 3.3 11.6 4.9 850 1.87 1.5 1.1 0.9 150
A5000 0.492 1.67 0.358 0.265 6,670 P4000 0.244 0.83 0.023 0.049 1,230
3.17 2.5 14.9 4.3 750 1.57 1.2 0.9 0.8 140
A1001 0.609 2.07 0.302 0.242 6,070 A3300 0.230 0.78 0.017 0.038 950
PrimeAngle

3.93 3.1 12.6 4.0 690 1.48 1.2 0.7 0.6 110
System

P9000 0.387 1.88 0.166 0.205 5,150 A4000 0.132 0.45 0.008 0.022 560
2.50 2.8 6.9 3.4 580 0.85 0.7 0.3 0.4 60
P1000 0.555 1.89 0.185 0.202 5,070 P6000 0.107 0.36 0.009 0.020 510
3.58 2.8 7.7 3.3 570 0.69 0.5 0.4 0.3 60
P3301 0.790 2.69 0.176 0.201 5,060 P7001 0.148 0.50 0.007 0.018 460
Product
Index

5.10 4.0 7.3 3.3 570 0.96 0.8 0.3 0.3 50


Combinations not shown in catalog are available on special order. P7000 0.074 0.25 0.002 0.007 170
Consult factory for more details. 0.48 0.4 0.1 0.1 20

24 15⁄8" Framing System


P1000® & P1001 Channels

P1000® 1 5⁄8" 41.3 Wt/100 Ft:189 Lbs (281 kg/100 m)

Channel
Allowable Moment 5,070 In-Lbs (570 N•m)

15⁄8"
7 22.2
3
⁄8" ⁄8" 3 9.5 9.5 12 Gauge Nominal Thickness .105" (2.7mm)
⁄8"
9 7.1
⁄32"

Telestrut
System
.915" 23.3
1 5⁄8" 1 41.3 1
.710" 18.0

Hardware
Nuts &
2 2

P1001 Wt/100 Ft: 378 Lbs (562 kg/100 m)


Allowable Moment 14,360 In-Lbs (1,620 N•m)
1 5⁄8" 41.3 12 Gauge Nominal Thickness .105" (2.7mm)

General
Fittings
Pipe/Conduit
3 1⁄4" 82.6 1

Supports
1

Electrical
2

Fittings
2

P1000 DS P1000 H3 P1000 HS

Concrete
Inserts
Wt/100 Ft: 173 Lbs (257 kg/100 m) Wt/100 Ft: 175 Lbs (260 kg/100 m) Wt/100 Ft:185 Lbs (275 kg/100 m)
9
Slots are 2 3⁄4" (69.9) x 7⁄8" (22.2)
9⁄16" (14.3) Dia. Holes ⁄16" (14.3) Dia. Holes
3 1⁄2" (88.9) on Center 1 7⁄8" (47.6) on Center 1 7⁄8" (47.6) on Center

11⁄4" Framing
System
3
⁄4"
(19.1)

Pipe Clamps can be


Mounted on Both Sides

Framing
System
P1000 KO P1000 SL P1000 T

13⁄16"
Wt/100 Ft: 190 Lbs (283 kg/100 m) Wt/100 Ft: 185 Lbs (275 kg/100 m) Wt/100 Ft: 185 Lbs (275 kg/100 m)

7
⁄8" (22.2) Knockouts Slots are 3" (76.2) x 13
⁄32" (10.3) Slots are 11⁄8" (28.6) x 9⁄16" (14.3)
4" (101.6) on Center 2" (51) on Center

Fiberglass
6" (152.4) on Center

System
1 3⁄16"
1" (30.2)
(25.4) 7
⁄8"
1
⁄2" (22.2)
(12.7)
Special
Metals

Channel Nuts (Refer to Hardware Section for Details)


P1006-0832 P1024 P3006-0832 P3016-0632
PrimeAngle

P1006-1024 P1012S P3006-1024 P3016-0832


System

P1006-1420 P1023S P3006-1420 P3016-1024


P1007 T
UNISTRU
T
P1008T P3007 P3016-1420
P1006T1420
RU
UNIST

P1008 P3008
P1009 P1010T P1012 P3009
P1010 P1023 P3010
Product

P1024S
Index

Channel Finishes: PL, GR, HG, PG; Standard Lengths: 10' & 20'

15⁄8" Framing System 25


® P1000 & P1001 Channels

BEAM LOADING – P1000 BEAM LOADING – P1001


Channel
15⁄8"

Max Defl. at Max Defl. at


Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360
Telestrut
System

In Lbs In Lbs Lbs Lbs In Lbs In Lbs Lbs Lbs


24 1,690 0.06 1,690 1,690 1,690 24 3,500 * 0.02 3,500 * 3,500 * 3,500 *
36 1,130 0.13 1,130 1,130 900 36 3,190 0.07 3,190 3,190 3,190
48 850 0.22 850 760 500 48 2,390 0.13 2,390 2,390 2,390
Hardware
Nuts &

60 680 0.35 650 480 320 60 1,910 0.20 1,910 1,910 1,620
72 560 0.50 450 340 220 72 1,600 0.28 1,600 1,600 1,130
84 480 0.68 330 250 160 84 1,370 0.39 1,370 1,240 830
96 420 0.89 250 190 130 96 1,200 0.51 1,200 950 630
General
Fittings

108 380 1.14 200 150 100 108 1,060 0.64 1,000 750 500
120 340 1.40 160 120 80 120 960 0.79 810 610 410
144 280 2.00 110 80 60 144 800 1.14 560 420 280
Pipe/Conduit

168 240 2.72 80 60 40 168 680 1.53 410 310 210


Supports

192 210 3.55 60 50 NR 192 600 2.02 320 240 160


216 190 4.58 50 40 NR 216 530 2.54 250 190 130
240 170 5.62 40 NR NR 240 480 3.16 200 150 100
Electrical
Fittings

COLUMN LOADING – P1000 COLUMN LOADING – P1001


Maximum Maximum
Unbraced Allowable Load Maximum Column Load Applied at C.G. Unbraced Allowable Load Maximum Column Load Applied at C.G.
Concrete
Inserts

Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
In Lbs Lbs Lbs Lbs Lbs In Lbs Lbs Lbs Lbs Lbs
24 3,550 10,740 9,890 8,770 7,740 24 6,430 24,280 23,610 22,700 21,820
36 3,190 8,910 7,740 6,390 5,310 36 6,290 22,810 21,820 20,650 19,670
11⁄4" Framing
System

48 2,770 7,260 6,010 4,690 3,800 48 6,160 21,410 20,300 18,670 16,160
60 2,380 5,910 4,690 3,630 2,960 60 6,000 20,210 18,670 15,520 12,390
72 2,080 4,840 3,800 2,960 2,400 72 5,620 18,970 16,160 12,390 8,950
84 1,860 4,040 3,200 2,480 1,980 84 5,170 16,950 13,630 9,470 6,580
96 1,670 3,480 2,750 2,110 1,660 96 4,690 14,890 11,190 7,250 5,040
⁄16" Framing

108 1,510 3,050 2,400 1,810 ** 108 4,170 12,850 8,950 5,730 3,980
System

120 1,380 2,700 2,110 ** ** 120 3,690 10,900 7,250 4,640 **


144 1,150 2,180 1,660 ** ** 144 2,930 7,630 5,040 ** **
13

Notes:
Fiberglass

ELEMENTS OF SECTION
System

* Load limited by spot weld shear.

P1000/P1001 ** KL⁄r > 200


NR = Not Recommended.
Parameter P1000 P1001 1. Above loads include the weight of the member. This weight must be
0.555 In2 1.111 In2
Special

Area of Section
Metals

deducted to arrive at the net allowable load the beam will support.
Axis 1-1 2. Long span beams should be supported in such a manner as to
Moment of Inertia (I) 0.185 In4 0.928 In4 prevent rotation and twist.
Section Modulus (S) 0.202 In3 0.571 In3 3. Allowable uniformly distributed loads are listed for various simple
PrimeAngle

spans, that is, a beam on two supports. If load is concentrated at


Radius of Gyration (r) 0.577 In 0.914 In
System

the center of the span, multiply load from the table by 0.5 and
Axis 2-2 corresponding deflection by 0.8.
Moment of Inertia (I) 0.236 In4 0.471 In4 4. See page 61 for lateral bracing reduction charts.
Section Modulus (S) 0.290 In3 0.580 In3 5. For Pierced Channel, Beam Load Values in the tables are multiplied
Radius of Gyration (r) 0.651 In 0.651 In by the following factor:
Product
Index

"DS" Series 70% "T" Series 85%


"KO" Series 95% "H3" Series 90%
"SL" Series 85% "HS" Series 90%

26 15⁄8" Framing System


P1000® & P1001 Channels

BEAM LOADING – P1000 (METRIC) BEAM LOADING – P1001 (METRIC)

Channel
15⁄8"
Max Defl. at Max Defl. at
Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360

Telestrut
System
mm kg mm kg kg kg mm kg mm kg kg kg
600 780 1 780 780 780 600 1,588 * 1 1,588 * 1,588 * 1,588 *
750 621 2 621 621 603 750 1,588 * 1 1,588 * 1,588 * 1,588 *
1,000 467 4 467 467 340 1,000 1,324 2 1,324 1,324 1,324

Hardware
Nuts &
1,250 372 6 372 327 218 1,250 1,057 3 1,057 1,057 1,057
1,500 313 9 304 227 150 1,500 885 5 885 885 757
1,750 268 12 222 168 109 1,750 757 7 757 757 558
2,000 236 15 168 127 86 2,000 662 9 662 640 426

General
Fittings
2,500 186 24 109 82 54 2,500 531 13 531 408 272
3,000 154 34 77 54 36 3,000 440 19 381 286 191
3,500 132 46 54 41 27 3,500 376 26 281 209 141

Pipe/Conduit
4,000 118 62 41 32 23 4,000 331 34 213 159 109

Supports
4,500 104 78 32 27 18 4,500 295 44 168 127 86
5,000 95 97 27 18 NR 5,000 263 53 136 104 68
6,000 77 136 18 NR NR 6,000 222 78 95 73 45

Electrical
Fittings
COLUMN LOADING – P1000 (METRIC) COLUMN LOADING – P1001 (METRIC)
Maximum Maximum
Unbraced Allowable Load Maximum Column Load Applied at C.G. Unbraced Allowable Load Maximum Column Load Applied at C.G.

Concrete
Inserts
Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
mm kg kg kg kg kg mm kg kg kg kg kg
600 1,615 4,899 4,522 4,019 3,552 600 2,917 11,031 10,737 10,328 9,934
750 1,547 4,491 4,019 3,443 2,944 750 2,889 10,709 10,328 9,838 9,403

11⁄4" Framing
System
1,000 1,393 3,819 3,266 2,658 2,168 1,000 2,835 10,160 9,689 9,144 8,555
1,250 1,234 3,225 2,658 2,068 1,678 1,250 2,785 9,652 9,144 8,328 7,153
1,500 1,093 2,726 2,168 1,678 1,365 1,500 2,731 9,208 8,555 7,153 5,752
1,750 980 2,313 1,814 1,411 1,148 1,750 2,595 8,836 7,629 5,978 4,436
2,000 885 1,973 1,560 1,211 975 2,000 2,436 8,097 6,681 4,863 3,393

Framing
2,250 807 1,728 1,365 1,057 839 2,250 2,263 7,330 5,752 3,865 2,681

System
2,500 739 1,533 1,211 925 ** 2,500 2,077 6,563 4,863 3,130 2,173

13⁄16"
2,750 685 1,379 1,084 821 ** 2,750 1,887 5,806 4,042 2,585 1,796

Notes:
ELEMENTS OF SECTION
Fiberglass
* Load limited by spot weld shear.

System
P1000/P1001 (METRIC) ** KL⁄r > 200
NR = Not Recommended.
Parameter P1000 P1001 1. Above loads include the weight of the member. This weight must be
3.58 cm2 7.16 cm2 deducted to arrive at the net allowable load the beam will support.
Special

Area of Section
Metals

Axis 1-1 2. Long span beams should be supported in such a manner as to


Moment of Inertia (I) 7.68 cm4 38.62 cm4 prevent rotation and twist.
3. Allowable uniformly distributed loads are listed for various simple
Section Modulus (S) 3.30 cm3 9.36 cm3
spans, that is, a beam on two supports. If load is concentrated at
PrimeAngle

Radius of Gyration (r) 1.46 cm 2.32 cm


System

the center of the span, multiply load from the table by 0.5 and
Axis 2-2 corresponding deflection by 0.8.
Moment of Inertia (I) 9.80 cm4 19.60 cm4 4. See page 61 for lateral bracing reduction charts.
Section Modulus (S) 4.75 cm3 9.50 cm3 5. For Pierced Channel, Beam Load Values in the tables are multiplied
Radius of Gyration (r) 1.65 cm 1.65 cm by the following factor:
Product

"DS" Series 70% "T" Series 85%


Index

"KO" Series 95% "H3" Series 90%


"SL" Series 85% "HS" Series 90%

15⁄8" Framing System 27


® P1000 Channel Combinations

P1001 T Wt/100 Ft: 378 Lbs (562 kg/100 m)


Allowable Moment 14,360 In-Lbs (1,620 N•m)
Channel

12 Gauge Nominal Thickness .105" (2.7mm)


15⁄8"

1 5 ⁄8 " 41.3
Telestrut
System

3 1⁄4" 82.6 1
1
Hardware
Nuts &

2 2
General
Fittings

P1001 A Wt/100 Ft: 378 Lbs (562 kg/100 m)


Allowable Moment 18,640 In-Lbs (2,110 N•m)
12 Gauge Nominal Thickness .105" (2.7mm)
1 5⁄8"
Pipe/Conduit

41.3
Supports

3 1⁄4" 1
82.6
1
Electrical
Fittings

.710" .915" 18.0 23.3


Concrete
Inserts

2 2

P1001 B Wt/100 Ft: 378 Lbs (562 kg/100 m)


Allowable Moment 18,640 In-Lbs (2,110 N•m)
11⁄4" Framing

12 Gauge Nominal Thickness .105" (2.7mm)


1 5 ⁄8 " 41.3
System

3 1⁄4" 82.6
⁄16" Framing

1 1
System
13

2 2
Fiberglass
System

P1001 C Wt/100 Ft: 378 Lbs (562 kg/100 m)


Allowable Moment 15,950 In-Lbs (1,800 N•m)
1 5⁄8" 41.3 12 Gauge Nominal Thickness .105" (2.7mm)
Special
Metals

1.677" 42.6
3 1⁄4" 82.6
PrimeAngle

1 1
System

1.574" 40.0

.761" .864" 19.3 22.0


Product
Index

2 2

Channel Finishes: PL, GR, HG, PG; Standard Lengths: 10' & 20'

28 15⁄8" Framing System


P1000 Channel Combinations

P1001 3 Wt/100 Ft: 566 Lbs (843 kg/100 m) P1001 D3 Wt/100 Ft: 566 Lbs (843 kg/100 m)
Allowable Moment 31,840 In-Lbs (3,600 N•m) Allowable Moment 17,550 In-Lbs (1,980 N•m)

Channel
12 Gauge Nominal Thickness .105" (2.7mm) 12 Gauge Nominal Thickness .105" (2.7mm)

15⁄8"
1 5⁄8"
(41.3)
3 1⁄4"
(82.6)

Telestrut
System
2.472"
(62.8) 1.388"
4 7⁄8" (35.2)
1
(123.8) 3 ⁄ 4" 1
1 (82.6)

Hardware
1.862"

Nuts &
2.403" (47.3)
(61.0)

2
2

General
Fittings
P1001 A3 Wt/100 Ft: 566 Lbs (843 kg/100 m) P1003 Wt/100 Ft: 333 Lbs (495 kg/100 m)
Allowable Moment 32,770 In-Lbs (3,700 N•m) Allowable Moment 6,240 In-Lbs (700 N•m)
12 Gauge Nominal Thickness .105" (2.7mm) 12 Gauge Nominal Thickness .105" (2.7mm)

Pipe/Conduit
1 5 ⁄8 "

Supports
(41.3)

147⁄64" 2 1.244"
(44.1) (31.6)
7
4 ⁄8 "
(123.8) 1 3⁄16"
1 (30.2)
1

Electrical
Fittings
41⁄32" .486"
(102.4) (12.5)
.778" .847"
(19.8) (21.5)

Concrete
2

Inserts
P1001 B3 Wt/100 Ft: 566 Lbs (843 kg/100 m) P1001 C41 Wt/100 Ft: 755 Lbs (1,124 kg/100 m)
Allowable Moment 37,550 In-Lbs (4,240 N•m) Allowable Moment 28,720 In-Lbs (3,250 N•m)
12 Gauge Nominal Thickness .105" (2.7mm) 12 Gauge Nominal Thickness .105" (2.7mm)

11⁄4" Framing
1 5 ⁄8 "

System
(41.3) 3 1⁄4"
(82.6)

4 7 ⁄8 "
(123.8) 3 1⁄4"
1 (82.6)

Framing
1

System
13⁄16"
.778" .847"
(19.8) (21.5)
2
2

Fiberglass
System
P1001 C3 Wt/100 Ft: 566 Lbs (843 kg/100 m) P1004 A Wt/100 Ft: 668 Lbs (994 kg/100 m)
Allowable Moment 18,680 In-Lbs (2,110 N•m) Allowable Moment 41,970 In-Lbs (4,740 N•m)
12 Gauge Nominal Thickness .105" (2.7mm) 12 Gauge Nominal Thickness .105" (2.7mm)
127⁄32" 7
(46.8) ⁄16"
3 1⁄4" 1 5⁄8" (11.1)
Special
Metals

(82.6) (41.3)

1.354"
(34.4)
4"
1 (101.6)
PrimeAngle

3 1 ⁄4 " 1
System

(82.6) 1.896" 4 7⁄8"


(48.2) (123.8)

1.930" 1.320"
7
(49.0) (33.5) 2 ⁄16"
Product

2 (11.1)
Index

Channel Finishes: PL, GR, HG, PG; Standard Lengths: 10' & 20' Channel Finishes: PL, GR, HG, PG; Standard Lengths: 10' & 20'

15⁄8" Framing System 29


® P1000 Channel Combinations

BEAM LOADING – P1001 C41 BEAM LOADING – P1004 A


Channel
15⁄8"

Max Defl. at Max Defl. at


Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360
Telestrut
System

In Lbs In Lbs Lbs Lbs In Lbs In Lbs Lbs Lbs


24 7,040 * 0.02 7,040 * 7,040 * 7,040 * 24 9,100 * 0.01 9,100 * 9,100 * 9,100 *
36 6,380 0.07 6,380 6,380 6,380 36 9,100 * 0.05 9,100 * 9,100 * 9,100 *
48 4,790 0.13 4,790 4,790 4,790 48 7,000 0.08 7,000 7,000 7,000
Hardware
Nuts &

60 3,830 0.20 3,830 3,830 3,240 60 5,600 0.13 5,600 5,600 5,600
72 3,190 0.28 3,190 3,190 2,250 72 4,660 0.19 4,660 4,660 4,660
84 2,740 0.39 2,740 2,480 1,660 84 4,000 0.26 4,000 4,000 3,630
General

96 2,390 0.50 2,390 1,900 1,270 96 3,500 0.34 3,500 3,500 2,780
Fittings

108 2,130 0.64 2,000 1,500 1,000 108 3,110 0.43 3,110 3,110 2,200
120 1,910 0.78 1,620 1,220 810 120 2,800 0.52 2,800 2,670 1,780
144 1,600 1.14 1,130 840 560 144 2,330 0.75 2,330 1,850 1,230
Pipe/Conduit

168 1,370 1.55 830 620 410 168 2,000 1.03 1,810 1,360 910
Supports

192 1,200 2.02 630 480 320 192 1,750 1.34 1,390 1,040 690
216 1,060 2.54 500 380 250 216 1,550 1.69 1,100 820 550
240 960 3.16 410 300 200 240 1,400 2.10 890 670 440
Electrical
Fittings

COLUMN LOADING – P1001 C41 COLUMN LOADING – P1004 A


Maximum Maximum
Unbraced Allowable Load Maximum Column Load Applied at C.G. Unbraced Allowable Load Maximum Column Load Applied at C.G.
Concrete
Inserts

Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
In Lbs Lbs Lbs Lbs Lbs In Lbs Lbs Lbs Lbs Lbs
24 12,690 46,920 44,980 42,360 39,890 24 11,420 36,800 33,890 30,440 27,600
36 12,250 42,680 39,890 36,660 34,050 36 10,600 30,840 27,600 24,400 22,160
11⁄4" Framing

48 11,820 38,740 35,720 32,640 30,430 48 9,860 26,400 23,560 21,060 19,470
System

60 11,470 35,500 32,640 29,980 28,220 60 9,160 23,370 21,060 19,160 18,020
72 11,180 32,970 30,430 28,220 26,820 72 8,610 21,310 19,470 18,020 17,140
84 10,900 31,040 28,840 27,010 24,870 84 8,170 19,890 18,410 17,260 15,240
96 10,580 29,570 27,680 26,170 19,840 96 7,790 18,890 17,670 16,760 11,670
⁄16" Framing

108 10,310 28,440 26,820 22,310 15,670 108 7,460 18,160 17,140 13,280 9,220
System

120 10,070 27,560 26,170 18,280 12,700 120 7,150 17,590 16,760 10,750 7,470
144 8,740 26,320 19,840 12,700 8,820 144 5,660 16,840 11,670 7,470 **
13

168 7,360 21,890 14,570 9,330 ** 168 4,520 12,990 8,570 ** **

ELEMENTS OF SECTION
Fiberglass
System

P1001 C41/ P1004 A


Parameter P1001 C41 P1004 A *Load limited by spot weld shear.
2 2 ** KL⁄r > 200
Area of Section 2.221 In 1.965 In
Special
Metals

Axis 1-1 Notes:


Moment of Inertia (I) 1.856 In4 4.068 In4 1. Above loads include the weight of the member. This weight must be
deducted to arrive at the net allowable load the beam will support.
Section Modulus (S) 1.142 In3 1.669 In3
2. Long span beams should be supported in such a manner as to
PrimeAngle

Radius of Gyration (r) 0.914 In 1.439 In


System

prevent rotation and twist.


Axis 2-2 3. Allowable uniformly distributed loads are listed for various simple
Moment of Inertia (I) 2.408 In4 1.092 In4 spans, that is, a beam on two supports. If load is concentrated at
Section Modulus (S) 1.482 In3 1.190 In3 the center of the span, multiply load from the table by 0.5 and
Radius of Gyration (r) 1.041 In 0.745 In corresponding deflection by 0.8.
Product

4. See page 61 for lateral bracing reduction charts.


Index

30 15⁄8" Framing System


P1000 Channel Combinations

BEAM LOADING – P1001 C41 (METRIC) BEAM LOADING – P1004 A (METRIC)

Channel
15⁄8"
Max Defl. at Max Defl. at
Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360

Telestrut
System
mm kg mm kg kg kg mm kg mm kg kg kg
600 3,193 * 1 3,193 * 3,193 * 3,193 * 600 4,128 * 0 4,128 * 4,128 * 4,128 *
750 3,193 * 1 3,193 * 3,193 * 3,193 * 750 4,128 * 1 4,128 * 4,128 * 4,128 *
1,000 2,649 2 2,649 2,649 2,649 1,000 3,869 1 3,869 3,869 3,869

Hardware
Nuts &
1,250 2,118 3 2,118 2,118 2,118 1,250 3,093 2 3,093 3,093 3,093
1,500 1,764 5 1,764 1,764 1,520 1,500 2,581 3 2,581 2,581 2,581
1,750 1,510 7 1,510 1,510 1,116 1,750 2,209 4 2,209 2,209 2,209

General
2,000 1,324 9 1,324 1,284 853 2,000 1,932 6 1,932 1,932 1,873

Fittings
2,500 1,057 13 1,057 821 549 2,500 1,547 9 1,547 1,547 1,197
3,000 885 19 757 572 381 3,000 1,288 13 1,288 1,247 835
3,500 757 26 558 417 281 3,500 1,107 18 1,107 916 612

Pipe/Conduit
4,000 662 34 426 322 213 4,000 966 23 934 703 467

Supports
4,500 590 44 336 254 168 4,500 862 29 739 553 372
5,000 531 54 272 204 136 5,000 776 36 599 449 299
6,000 440 77 191 141 95 6,000 644 52 417 313 209

Electrical
Fittings
COLUMN LOADING – P1001 C41 (METRIC) COLUMN LOADING – P1004 A (METRIC)
Maximum Maximum
Unbraced Allowable Load Maximum Column Load Applied at C.G. Unbraced Allowable Load Maximum Column Load Applied at C.G.

Concrete
Inserts
Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
mm kg kg kg kg kg mm kg kg kg kg kg
600 5,761 21,342 20,475 19,305 18,194 600 5,194 16,787 15,481 13,921 12,628
750 5,665 20,403 19,305 17,930 16,733 750 5,003 15,377 13,921 12,347 11,163

11⁄4" Framing
1,000 5,498 18,833 17,509 16,039 14,900 1,000 4,717 13,349 11,916 10,546 9,621

System
1,250 5,343 17,409 16,039 14,660 13,676 1,250 4,436 11,812 10,546 9,439 8,745
1,500 5,212 16,207 14,900 13,676 12,859 1,500 4,173 10,691 9,621 8,745 8,215
1,750 5,103 15,223 14,030 12,977 12,306 1,750 3,964 9,875 8,986 8,287 7,856
2,000 5,012 14,433 13,367 12,469 11,911 2,000 3,787 9,276 8,537 7,961 7,625

Framing
2,250 4,885 13,803 12,859 12,093 10,392 2,250 3,638 8,831 8,215 7,729 6,214

System
2,500 4,776 13,299 12,469 11,671 8,559 2,500 3,502 8,491 7,961 7,248 5,035

13⁄16"
2,750 4,677 12,891 12,156 10,079 7,076 2,750 3,379 8,233 7,770 5,992 4,159

ELEMENTS OF SECTION
Fiberglass
System
P1001 C41/ P1004 A (METRIC)
Parameter P1001 C41 P1004 A *Load limited by spot weld shear.

Area of Section 14.33 cm 2


12.68 cm 2 ** KL⁄r > 200
Special
Metals

Axis 1-1 Notes:


Moment of Inertia (I) 77.24 cm4 169.33 cm4 1. Above loads include the weight of the member. This weight must be
deducted to arrive at the net allowable load the beam will support.
Section Modulus (S) 18.71 cm3 27.35 cm3
2. Long span beams should be supported in such a manner as to
PrimeAngle

Radius of Gyration (r) 2.32 cm 3.66 cm


prevent rotation and twist.
System

Axis 2-2
3. Allowable uniformly distributed loads are listed for various simple
Moment of Inertia (I) 100.24 cm4 45.44 cm4 spans, that is, a beam on two supports. If load is concentrated at
Section Modulus (S) 24.29 cm3 19.50 cm3 the center of the span, multiply load from the table by 0.5 and
Radius of Gyration (r) 2.64 cm 1.89 cm corresponding deflection by 0.8.
Product

4. See page 61 for lateral bracing reduction charts.


Index

15⁄8" Framing System 31


® P1100 & P1101 Channels

P1100 Wt/100 Ft: 142 Lbs (211 kg/100 m)


Channel

Allowable Moment 4,060 In-Lbs (460 N•m)


15⁄8"

1 5⁄8" 41.3
14 Gauge Nominal Thickness .075" (1.9mm)
7
⁄8" 22.2
3
⁄8" 3
⁄8" 9.5 9.5
9 7.1
⁄32"
Telestrut
System

.903" 23.1
1 5⁄8" 1 41.3 1
.722" 18.3
Hardware
Nuts &

2 2

P1101 Wt/100 Ft: 284 Lbs (423 kg/100 m)


Allowable Moment 11,340 In-Lbs (1,280 N•m)
General
Fittings

14 Gauge Nominal Thickness .075" (1.9mm)


1 5⁄8" 41.3
Pipe/Conduit
Supports

3 1⁄4" 1
82.6 1
Electrical
Fittings

2 2
Concrete
Inserts

P1100 HS P1100 KO
Wt/100 Ft: 136 Lbs (202 kg/100 m) Wt/100 Ft: 140 Lbs (208 kg/100 m)
11⁄4" Framing
System

9⁄16" (14.3) Dia. Holes 7


⁄8" (22.2) Knockouts
1 7⁄8" (47.6) on Center 6" (152.4) on Center
⁄16" Framing
System

P1100 SL P1100 T
Wt/100 Ft: 136 Lbs (202 kg/100 m) Wt/100 Ft: 136 Lbs (202 kg/100 m)
13
Fiberglass
System

Slots are Slots are


3" (76.2) x 13⁄32" (10.3) 11⁄8" (28.6) x 9⁄16" (14.3)
4" (101.6) on Center 2" (51) on Center 7
1 3⁄16"
⁄8" (30.2)
1
⁄2" 1" (22.2)
(12.7) (25.4)
Special
Metals

Channel Nuts (Refer to Hardware Section for Details)


P1006-0832 P1024 P3006-0832 P3016-0632
PrimeAngle

P1006-1024 P1012S P3006-1024 P3016-0832


System

P1006-1420 UNISTRU
P1023S P3006-1420 P3016-1024
P1007 T
T
P1008T P3007 P3016-1420
RU

P1008
UNIST
P1006T1420 P3008
P1009 P1010T P1012 P3009
P1010 P1023 P3010
Product

P1024S
Index

Channel Finishes: PL, GR, HG, PG; Standard Lengths: 10' & 20'

32 15⁄8" Framing System


P1100 Channel Combinations

P1101 A Wt/100 Ft: 284 Lbs (423 kg/100 m)

Channel
Allowable Moment 14,000 In-Lbs (1,580 N•m)

15⁄8"
14 Gauge Nominal Thickness .075" (1.9mm)
1 5⁄8" 41.3

Telestrut
System
3 1⁄4" 82.6
1
1

Hardware
Nuts &
.729" .896" 18.5 22.8

General
Fittings
2 2

Pipe/Conduit
Supports
P1101 B Wt/100 Ft: 284 Lbs (423 kg/100 m)
Allowable Moment 14,000 In-Lbs (1,580 N•m)
14 Gauge Nominal Thickness .075" (1.9mm)

Electrical
Fittings
1 5⁄8" 41.3

Concrete
Inserts
3 1⁄4" 82.6
1 1

11⁄4" Framing
System
2 2

Framing
System
13⁄16"
P1101 C Wt/100 Ft: 284 Lbs (423 kg/100 m)
Allowable Moment 12,330 In-Lbs (1,390 N•m)

Fiberglass
System
14 Gauge Nominal Thickness .075" (1.9mm)

1 5⁄8" 41.3 Special


Metals

1.666" 42.4
1
3 ⁄4" 82.6
1 1
PrimeAngle

40.2
System

1.583"

.771" .854" 19.6 21.7


2 2
Product
Index

Channel Finishes: PL, GR, HG, PG; Standard Lengths: 10' & 20'
15⁄8" Framing System 33
® P1100 & P1101 Channels

BEAM LOADING – P1100 BEAM LOADING – P1101


Channel
15⁄8"

Max Defl. at Max Defl. at


Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360
Telestrut
System

In Lbs In Lbs Lbs Lbs In Lbs In Lbs Lbs Lbs


24 1,350 0.06 1,350 1,350 1,350 24 2,180 * 0.02 2,180 * 2,180 * 2,180 *
36 900 0.13 900 900 700 36 2,180 * 0.06 2,180 * 2,180 * 2,180 *
Hardware

48 680 0.23 680 590 400 48 1,890 0.13 1,890 1,890 1,890
Nuts &

60 540 0.36 510 380 250 60 1,510 0.20 1,510 1,510 1,280
72 450 0.51 350 260 180 72 1,260 0.28 1,260 1,260 890
84 390 0.70 260 190 130 84 1,080 0.39 1,080 980 650
General
Fittings

96 340 0.92 200 150 100 96 950 0.51 950 750 500
108 300 1.15 160 120 80 108 840 0.64 790 590 400
120 270 1.42 130 90 60 120 760 0.79 640 480 320
144 230 2.09 90 70 40 144 630 1.13 440 330 220
Pipe/Conduit

168 190 2.75 60 50 30 168 540 1.54 330 250 160


Supports

192 170 3.67 50 40 NR 192 470 2.00 250 190 130


216 150 4.61 40 30 NR 216 420 2.55 200 150 100
240 140 5.90 30 NR NR 240 380 3.16 160 120 80
Electrical
Fittings

COLUMN LOADING – P1100 COLUMN LOADING – P1101


Maximum Maximum
Unbraced Allowable Load Maximum Column Load Applied at C.G. Unbraced Allowable Load Maximum Column Load Applied at C.G.
Concrete
Inserts

Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
In Lbs Lbs Lbs Lbs Lbs In Lbs Lbs Lbs Lbs Lbs
24 2,800 8,040 7,330 6,360 5,430 24 5,010 18,250 17,700 16,880 16,030
11⁄4" Framing

36 2,410 6,480 5,430 4,190 3,210 36 4,860 16,990 16,030 14,770 13,620
System

48 1,940 4,990 3,830 2,760 2,160 48 4,700 15,610 14,380 12,930 11,750
60 1,550 3,740 2,760 2,050 1,640 60 4,480 14,280 12,930 11,490 9,290
72 1,290 2,860 2,160 1,640 1,320 72 4,210 13,100 11,750 9,290 6,700
84 1,100 2,310 1,780 1,370 1,110 84 3,880 12,090 10,220 7,090 4,930
⁄16" Framing

96 950 1,950 1,520 1,180 950 96 3,480 11,170 8,390 5,430 3,770
System

108 840 1,690 1,320 1,030 ** 108 3,060 9,640 6,700 4,290 2,980
120 760 1,490 1,180 ** ** 120 2,680 8,170 5,430 3,480 **
144 630 1,210 950 ** ** 144 2,090 5,710 3,770 ** **
13

Notes:
ELEMENTS OF SECTION
Fiberglass
System

* Load limited by spot weld shear.


P1100/P1101 ** KL⁄r > 200
NR = Not Recommended.
Parameter P1100 P1101
1. Above loads include the weight of the member. This weight must be
Special

2 2
Metals

Area of Section 0.418 In 0.835 In


deducted to arrive at the net allowable load the beam will support.
Axis 1-1 2. Long span beams should be supported in such a manner as to
Moment of Inertia (I) 0.145 In4 0.733 In4 prevent rotation and twist.
Section Modulus (S) 0.162 In3 0.451 In3 3. Allowable uniformly distributed loads are listed for various simple
PrimeAngle

Radius of Gyration (r) 0.589 In 0.937 In spans, that is, a beam on two supports. If load is concentrated at
System

Axis 2-2 the center of the span, multiply load from the table by 0.5 and
corresponding deflection by 0.8.
Moment of Inertia (I) 0.176 In4 0.353 In4
4. See page 61 for lateral bracing reduction charts.
Section Modulus (S) 0.217 In3 0.434 In3
5. For Pierced Channel, Beam Load Values in the tables are multiplied
Radius of Gyration (r) 0.650 In 0.650 In by the following factor:
Product
Index

"T" Series ... 85% "KO" Series .. 95%


"SL" Series ... 85% "HS" Series .. 90%

34 15⁄8" Framing System


P1100 & P1101 Channels

BEAM LOADING – P1100 (METRIC) BEAM LOADING – P1101 (METRIC)

Channel
15⁄8"
Max Defl. at Max Defl. at
Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360

Telestrut
System
mm kg mm kg kg kg mm kg mm kg kg kg
600 626 1 626 626 626 600 989 * 0 989 * 989 * 989 *
750 499 2 499 499 476 750 989 * 1 989 * 989 * 989 *

Hardware
1,000 376 4 376 376 268 1,000 989 * 2 989 * 989 * 989 *

Nuts &
1,250 299 6 299 254 172 1,250 835 3 835 835 835
1,500 249 9 236 177 118 1,500 699 5 699 699 599
1,750 213 12 172 132 86 1,750 599 7 599 599 440

General
Fittings
2,000 186 15 132 100 68 2,000 522 9 522 508 336
2,500 150 24 86 64 41 2,500 417 13 417 322 218
3,000 127 36 59 45 32 3,000 349 19 299 227 150
3,500 109 49 45 32 23 3,500 299 26 222 163 109

Pipe/Conduit
4,000 95 64 32 27 18 4,000 263 35 168 127 86

Supports
4,500 82 77 27 18 14 4,500 231 43 132 100 68
5,000 77 100 23 18 NR 5,000 209 54 109 82 54
6,000 64 143 14 NR NR 6,000 172 77 77 54 36

Electrical
Fittings
COLUMN LOADING – P1100 (METRIC) COLUMN LOADING – P1101 (METRIC)
Maximum Maximum
Unbraced Allowable Load Maximum Column Load Applied at C.G. Unbraced Allowable Load Maximum Column Load Applied at C.G.

Concrete
Inserts
Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
mm kg kg kg kg kg mm kg kg kg kg kg
600 1,275 3,665 3,352 2,921 2,499 600 2,272 8,296 8,051 7,688 7,307

11⁄4" Framing
750 1,207 3,329 2,921 2,400 1,941 750 2,241 8,029 7,688 7,212 6,745

System
1,000 1,034 2,744 2,241 1,674 1,279 1,000 2,186 7,530 7,053 6,450 5,910
1,250 862 2,200 1,674 1,207 948 1,250 2,123 7,017 6,450 5,788 5,257
1,500 717 1,737 1,279 948 757 1,500 2,041 6,523 5,910 5,257 4,314
1,750 608 1,379 1,034 785 630 1,750 1,941 6,069 5,457 4,486 3,320

Framing
2,000 531 1,143 875 667 544 2,000 1,837 5,674 5,012 3,642 2,545

System
2,250 472 980 757 585 476 2,250 1,692 5,330 4,314 2,894 2,009
2,500 417 857 667 517 ** 2,500 1,538 4,926 3,642 2,345 1,628

13⁄16"
2,750 381 762 599 463 ** 2,750 1,383 4,354 3,025 1,937 1,343

Notes:

Fiberglass
ELEMENTS OF SECTION

System
* Load limited by spot weld shear.
P1100/P1101 (METRIC) ** KL⁄r > 200
NR = Not Recommended.
Parameter P1100 P1101
1. Above loads include the weight of the member. This weight must be
Special
Metals

Area of Section 2.69 cm2 5.39 cm2 deducted to arrive at the net allowable load the beam will support.
Axis 1-1 2. Long span beams should be supported in such a manner as to
Moment of Inertia (I) 6.03 cm4 30.51 cm4 prevent rotation and twist.
Section Modulus (S) 2.65 cm3 7.39 cm3 3. Allowable uniformly distributed loads are listed for various simple
PrimeAngle

spans, that is, a beam on two supports. If load is concentrated at


Radius of Gyration (r) 1.50 cm 2.38 cm
System

the center of the span, multiply load from the table by 0.5 and
Axis 2-2 corresponding deflection by 0.8.
Moment of Inertia (I) 7.34 cm4 14.69 cm4 4. See page 61 for lateral bracing reduction charts.
Section Modulus (S) 3.56 cm3 7.12 cm3 5. For Pierced Channel, Beam Load Values in the tables are multiplied
Radius of Gyration (r) 1.65 cm 1.65 cm by the following factor:
Product
Index

"T" Series ... 85% "KO" Series .. 95%


"SL" Series ... 85% "HS" Series .. 90%

15⁄8" Framing System 35


® P2000 & P2001 Channels

P2000 Wt/100 Ft: 116 Lbs (173 kg/100 m)


Channel

1 5⁄8" 41.3 Allowable Moment 3,520 In-Lbs (400 N•m)


15⁄8"

7
⁄8" 22.2 16 Gauge Nominal Thickness .060" (1.5mm)
3
⁄8" 3
⁄8" 9.5 9.5
9
⁄32" 7.1
Telestrut
System

.890" 22.6
1 5⁄8" 1 41.3 1
.735" 18.7
Hardware
Nuts &

2 2

P2001 Wt/100 Ft: 232 Lbs (346 kg/100 m)


Allowable Moment 9,570 In-Lbs (1,080 N•m)
1 5⁄8" 41.3 16 Gauge Nominal Thickness .060" (1.5mm)
General
Fittings
Pipe/Conduit
Supports

3 1⁄4" 82.6
1 1
Electrical
Fittings

2 2

P2000 HS P2000 KO
Concrete
Inserts

Wt/100 Ft: 113 Lbs (168 kg/100 m) Wt/100 Ft: 117 Lbs (174 kg/100 m)
11⁄4" Framing
System

9⁄16" (14.3) Dia. Holes 7


⁄8" (22.2) Knockouts
1 7⁄8" (47.6) on Center 6" (152.4) on Center
⁄16" Framing

P2000 SL P2000 T
System

Wt/100 Ft: 113 Lbs (168 kg/100 m) Wt/100 Ft: 113 Lbs (168 kg/100 m)
13
Fiberglass

Slots are Slots are


System

3" (76.2) x 13⁄32" (10.3) 11⁄8" (28.6) x 9⁄16" (14.3)


4" (101.6) on Center 2" (51) on Center 7
⁄8" 1 3⁄16"
1" (30.2)
1
⁄2" (22.2)
(25.4)
(12.7)
Special
Metals

Channel Nuts (Refer to Hardware Section for Details)


P1006-0832 P1024 P3006-0832 P3016-0632
PrimeAngle

P1006-1024 P1012S P3006-1024 P3016-0832


System

P1006-1420 UNISTRU
P1023S P3006-1420 P3016-1024
P1007 RU
T
T
P1008T P3007 P3016-1420
UNIST

P1008 P1006T1420 P3008


P1009 P1010T P1012 P3009
P1010 P1023 P3010
Product

P1024S
Index

Channel Finishes: PL, GR, HG, PG; Standard Lengths: 10' & 20'

36 15⁄8" Framing System


P2000 Channel Combinations

P2001 A Wt/100 Ft: 232 Lbs (346 kg/100 m)

Channel
Allowable Moment 11,660 In-Lbs (1,320 N•m)

15⁄8"
16 Gauge Nominal Thickness .060" (1.5mm)

1 5⁄8" 41.3

Telestrut
System
3 1⁄4"

Hardware
82.6

Nuts &
1 1

General
Fittings
.735" .890" 18.7 22.6
2 2

Pipe/Conduit
Supports
P2001 B Wt/100 Ft: 232 Lbs (346 kg/100 m)
Allowable Moment 11,660 In-Lbs (1,320 N•m)
16 Gauge Nominal Thickness .060" (1.5mm)

Electrical
Fittings
1 5⁄8" 41.3

Concrete
Inserts
11⁄4" Framing
3 1⁄4" 82.6
1 1

System
2

Framing
2

System
13⁄16"
P2001 C Wt/100 Ft: 232 Lbs (346 kg/100 m)
Allowable Moment 10,350 In-Lbs (1,170 N•m)

Fiberglass
System
16 Gauge Nominal Thickness .060" (1.5mm)
1 5⁄8" 41.3
Special
Metals

1.664" 42.3
3 1⁄4" 82.6
1 1
1.586" 40.3
PrimeAngle
System

.774" .851"
19.7 21.6
2 2
Product
Index

Channel Finishes: PL, GR, HG, PG; Standard Lengths: 10' & 20'
15⁄8" Framing System 37
® P2000 & P2001 Channels

BEAM LOADING – P2000 BEAM LOADING – P2001 CHANNEL


Channel
15⁄8"

Max Defl. at Max Defl. at


Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360
Telestrut
System

In Lbs In Lbs Lbs Lbs In Lbs In Lbs Lbs Lbs


24 1,170 0.06 1,170 1,170 1,170 24 1,610 * 0.02 1,610 * 1,610 * 1,610 *
36 780 0.13 780 780 610 36 1,610 * 0.05 1,610 * 1,610 * 1,610 *
48 590 0.23 590 510 340 48 1,600 0.13 1,600 1,600 1,600
Hardware
Nuts &

60 470 0.36 440 330 220 60 1,280 0.20 1,280 1,280 1,080
72 390 0.52 300 230 150 72 1,060 0.28 1,060 1,060 750
84 340 0.71 220 170 110 84 910 0.38 910 830 550
General

96 290 0.91 170 130 90 96 800 0.51 800 630 420


Fittings

108 260 1.16 130 100 70 108 710 0.64 670 500 330
120 230 1.41 110 80 50 120 640 0.79 540 410 270
144 200 2.12 80 60 40 144 530 1.13 380 280 190
Pipe/Conduit

168 170 2.86 60 40 30 168 460 1.56 280 210 140


Supports

192 150 3.76 40 30 20 192 400 2.02 210 160 110


216 130 4.64 30 30 NR 216 350 2.52 170 130 80
240 120 5.88 30 NR NR 240 320 3.16 140 100 70
Electrical
Fittings

COLUMN LOADING – P2000 COLUMN LOADING – P2001


Maximum Maximum
Concrete

Unbraced Allowable Load Maximum Column Load Applied at C.G. Unbraced Allowable Load Maximum Column Load Applied at C.G.
Inserts

Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
In Lbs Lbs Lbs Lbs Lbs In Lbs Lbs Lbs Lbs Lbs
24 2,400 6,650 6,080 5,280 4,470 24 4,200 15,030 14,600 13,940 13,220
11⁄4" Framing

36 2,050 5,380 4,470 3,370 2,500 36 4,070 14,030 13,220 12,090 10,990
System

48 1,600 4,090 3,040 2,100 1,590 48 3,920 12,850 11,720 10,290 9,040
60 1,230 2,960 2,100 1,500 1,160 60 3,700 11,630 10,290 8,760 7,530
72 970 2,190 1,590 1,160 910 72 3,410 10,460 9,040 7,530 5,740
84 790 1,720 1,270 950 760 84 3,140 9,410 7,990 6,080 4,220
⁄16" Framing

96 660 1,410 1,060 800 650 96 2,890 8,490 7,120 4,650 3,230
System

108 570 1,200 910 700 ** 108 2,530 7,700 5,740 3,680 2,550
120 510 1,040 800 620 ** 120 2,210 6,950 4,650 2,980 **
144 420 830 650 ** ** 144 1,690 4,890 3,230 ** **
13

Notes:
ELEMENTS OF SECTION
Fiberglass
System

* Load limited by spot weld shear.


P2000/P2001 ** KL⁄r > 200
Parameter P2000 P2001 NR = Not Recommended.
Area of Section 0.342 In2 0.684 In2 1. Above loads include the weight of the member. This weight must be
Special
Metals

Axis 1-1 deducted to arrive at the net allowable load the beam will support.
Moment of Inertia (I) 0.125 In4 0.618 In4 2. Long span beams should be supported in such a manner as to
prevent rotation and twist.
Section Modulus (S) 0.140 In3 0.381 In3
3. Allowable uniformly distributed loads are listed for various simple
PrimeAngle

Radius of Gyration (r) 0.604 In 0.951 In spans, that is, a beam on two supports. If load is concentrated at
System

Axis 2-2 the center of the span, multiply load from the table by 0.5 and
Moment of Inertia (I) 0.151 In4 0.302 In4 corresponding deflection by 0.8.
Section Modulus (S) 0.186 In3 0.372 In3 4. See page 61 for lateral bracing reduction charts.
Radius of Gyration (r) 0.665 In 0.665 In 5. For Pierced Channel, Beam Load Values in the tables are multiplied
Product

by the following factor:


Index

"T" Series ... 85% "KO" Series .. 95%


"SL" Series ... 85% "HS" Series .. 90%

38 15⁄8" Framing System


P2000 & P2001 Channels

BEAM LOADING – P2000 (METRIC) BEAM LOADING – P2001 CHANNEL (METRIC)

Channel
15⁄8"
Max Defl. at Max Defl. at
Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360

Telestrut
System
mm kg mm kg kg kg mm kg mm kg kg kg
600 540 1 540 540 540 600 730 * 0 730 * 730 * 730 *
750 431 2 431 431 408 750 730 * 1 730 * 730 * 730 *
1,000 327 4 327 327 231 1,000 730 * 2 730 * 730 * 730 *

Hardware
Nuts &
1,250 259 6 259 222 145 1,250 708 3 708 708 708
1,500 218 9 204 154 100 1,500 590 5 590 590 508
1,750 186 12 150 113 77 1,750 503 7 503 503 372

General
2,000 163 16 113 86 59 2,000 440 9 440 426 286

Fittings
2,500 132 25 73 54 36 2,500 354 13 354 272 181
3,000 109 36 50 36 27 3,000 295 19 254 191 127
3,500 91 47 36 27 18 3,500 254 27 186 141 91

Pipe/Conduit
4,000 82 63 27 23 14 4,000 222 35 141 109 73

Supports
4,500 73 80 23 18 9 4,500 195 43 113 86 54
5,000 64 96 18 14 9 5,000 177 54 91 68 45
6,000 54 142 14 NR NR 6,000 145 76 64 45 32

Electrical
Fittings
COLUMN LOADING – P2000 (METRIC) COLUMN LOADING – P2001 (METRIC)
Maximum Maximum

Concrete
Unbraced Allowable Load Maximum Column Load Applied at C.G. Unbraced Allowable Load Maximum Column Load Applied at C.G.

Inserts
Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
mm kg kg kg kg kg mm kg kg kg kg kg
600 1,089 3,035 2,781 2,422 2,064 600 1,905 6,831 6,641 6,346 6,028

11⁄4" Framing
750 1,030 2,758 2,422 1,973 1,565 750 1,878 6,622 6,346 5,947 5,525

System
1,000 871 2,272 1,833 1,320 980 1,000 1,828 6,219 5,806 5,248 4,717
1,250 708 1,796 1,320 916 694 1,250 1,769 5,770 5,248 4,590 4,023
1,500 567 1,379 980 694 535 1,500 1,687 5,316 4,717 4,023 3,465
1,750 467 1,066 771 558 440 1,750 1,583 4,881 4,237 3,547 2,844

Framing
2,000 390 862 630 467 372 2,000 1,479 4,472 3,819 3,103 2,177

System
2,250 336 721 535 404 322 2,250 1,383 4,100 3,465 2,477 1,719
2,500 290 617 467 354 286 2,500 1,279 3,774 3,103 2,009 1,393

13⁄16"
2,750 259 540 413 318 ** 2,750 1,148 3,484 2,595 1,660 1,152

Notes:
ELEMENTS OF SECTION
Fiberglass
System
* Load limited by spot weld shear.
P2000/P2001 (METRIC) ** KL⁄r > 200
Parameter P2000 P2001 NR = Not Recommended.
2 2 1. Above loads include the weight of the member. This weight must be
Area of Section 2.21 cm 4.41 cm
Special
Metals

Axis 1-1 deducted to arrive at the net allowable load the beam will support.
2. Long span beams should be supported in such a manner as to
Moment of Inertia (I) 5.19 cm4 25.74 cm4
prevent rotation and twist.
Section Modulus (S) 2.29 cm3 6.24 cm3
3. Allowable uniformly distributed loads are listed for various simple
PrimeAngle

Radius of Gyration (r) 1.53 cm 2.42 cm spans, that is, a beam on two supports. If load is concentrated at
System

Axis 2-2 the center of the span, multiply load from the table by 0.5 and
Moment of Inertia (I) 6.29 cm4 12.58 cm4 corresponding deflection by 0.8.
Section Modulus (S) 3.05 cm3 6.10 cm3 4. See page 61 for lateral bracing reduction charts.
Radius of Gyration (r) 1.69 cm 1.69 cm 5. For Pierced Channel, Beam Load Values in the tables are multiplied
by the following factor:
Product
Index

"T" Series ... 85% "KO" Series .. 95%


"SL" Series ... 85% "HS" Series .. 90%

15⁄8" Framing System 39


® P3000 & P3001 Channels

P3000 Wt/100 Ft: 170 Lbs (253 kg/100 m)


Channel

Allowable Moment 3,840 In-Lbs (430 N•m)


15⁄8"

1 5⁄8" 41.3 12 Gauge Nominal Thickness .105" (2.7mm)


7 22.2
3
⁄8" ⁄8" 3 9.5 9.5
⁄8"
9 7.1
⁄32"
Telestrut
System

.784" 19.9
1 3⁄8" 1 34.9 1
.591" 15.0
Hardware
Nuts &

2 2

P3001 Wt/100 Ft: 340 Lbs (506 kg/100 m)


General
Fittings

Allowable Moment 10,810 In-Lbs (1,220 N•m)


12 Gauge Nominal Thickness .105" (2.7mm)
1 5⁄8" 41.3
Pipe/Conduit
Supports

2 3⁄4" 69.9
1 1
Electrical
Fittings

2 2
Concrete
Inserts

P3000 HS P3000 KO P3000 SL


Wt/100 Ft: 165 Lbs (246 kg/100 m) Wt/100 Ft: 170 Lbs (253 kg/100 m) Wt/100 Ft: 165 Lbs (246 kg/100 m)
Slots are
3" (76.2) x 13⁄32" (10.3)
11⁄4" Framing

4" (101.6) on Center


System

9⁄16" (14.3) Dia. Holes 7


⁄8" (22.2) Knockouts
1 7⁄8" (47.6) on Center 6" (152.4) on Center 1
1"
⁄2"
⁄16" Framing

(25.4)
(12.7)
System

P3000 T P3001 T
Wt/100 Ft: 165 Lbs (246 kg/100 m) Wt/100 Ft: 340 Lbs (506 kg/100 m)
Slots are Slots are
13

11⁄8" (28.6) x 9⁄16" (14.3) 11⁄8" (28.6) x 9⁄16" (14.3)


2" (51) on Center 2" (51) on Center
Fiberglass
System

7
1 3⁄16" 7
⁄8" ⁄8"
(30.2) 1 3⁄16" (22.2)
Special

(22.2)
Metals

(30.2)

Channel Nuts (Refer to Hardware Section for Details)


P1006-0832 P1024 P3006-0832 P3016-0632
PrimeAngle

P1006-1024 P1012S P3006-1024 P3016-0832


System

P1006-1420 P1023S P3006-1420 P3016-1024


P1007
UNISTRU

T
T
P1008T P3007 P3016-1420
RU

P1008
UNIST
P1006T1420 P3008
P1009 P1010T P1012 P3009
P1010 P1023 P3010
Product

P1024S
Index

Channel Finishes: PL, GR, HG, PG; Standard Lengths: 10' & 20'

40 15⁄8" Framing System


P3000 & P3001 Channels

BEAM LOADING – P3000 BEAM LOADING – P3001

Channel
15⁄8"
Max Defl. at Max Defl. at
Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360

Telestrut
System
In Lbs In Lbs Lbs Lbs In Lbs In Lbs Lbs Lbs
24 1,280 0.07 1,280 1,280 1,280 24 2,960 * 0.03 2,960 * 2,960 * 2,960 *
36 850 0.15 850 850 580 36 2,400 0.08 2,400 2,400 2,400

Hardware
48 640 0.26 640 490 330 48 1,800 0.15 1,800 1,800 1,610

Nuts &
60 510 0.41 420 310 210 60 1,440 0.23 1,440 1,440 1,030
72 430 0.59 290 220 150 72 1,200 0.33 1,200 1,080 720
84 370 0.81 210 160 110 84 1,030 0.46 1,030 790 530

General
Fittings
96 320 1.05 160 120 80 96 900 0.59 810 610 400
108 280 1.30 130 100 60 108 800 0.75 640 480 320
120 260 1.66 100 80 50 120 720 0.93 520 390 260
144 210 2.32 70 50 40 144 600 1.34 360 270 180

Pipe/Conduit
168 180 3.15 50 40 30 168 510 1.81 260 200 130

Supports
192 160 4.18 40 30 NR 192 450 2.38 200 150 100
216 140 5.21 NR NR NR 216 400 3.01 160 120 80
240 130 6.64 NR NR NR 240 360 3.72 130 100 NR

Electrical
Fittings
COLUMN LOADING – P3000 COLUMN LOADING – P3001
Maximum Maximum
Unbraced Allowable Load Maximum Column Load Applied at C.G. Unbraced Allowable Load Maximum Column Load Applied at C.G.

Concrete
Inserts
Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
In Lbs Lbs Lbs Lbs Lbs In Lbs Lbs Lbs Lbs Lbs
24 3,180 9,690 8,980 8,050 7,210 24 5,740 21,780 21,200 20,430 19,720

11⁄4" Framing
36 2,920 8,160 7,210 6,130 5,240 36 5,620 20,520 19,720 18,830 17,680

System
48 2,590 6,820 5,810 4,730 3,860 48 5,520 19,400 18,570 16,570 14,260
60 2,300 5,740 4,730 3,690 2,990 60 5,330 18,510 16,570 13,670 10,810
72 2,040 4,850 3,860 2,990 2,270 72 5,030 16,850 14,260 10,810 7,730
84 1,830 4,100 3,240 2,400 ** 84 4,630 14,990 11,930 8,180 5,680

Framing
96 1,650 3,530 2,770 1,840 ** 96 4,190 13,090 9,720 6,260 4,350

System
108 1,450 3,080 2,270 ** ** 108 3,720 11,230 7,730 4,950 **
120 1,250 2,710 1,840 ** ** 120 3,300 9,460 6,260 4,010 **

13⁄16"
144 2,620 6,590 4,350 ** **

Fiberglass
Notes:
ELEMENTS OF SECTION

System
* Load limited by spot weld shear.
P3000/P3001 ** KL⁄r > 200
Parameter P3000 P3001 NR = Not Recommended.
Area of Section 0.500 In2 1.000 In2 1. Above loads include the weight of the member. This weight must be
Special
Metals

Axis 1-1 deducted to arrive at the net allowable load the beam will support.
Moment of Inertia (I) 0.120 In4 0.591 In4 2. Long span beams should be supported in such a manner as to
prevent rotation and twist.
Section Modulus (S) 0.153 In3 0.430 In3
3. Allowable uniformly distributed loads are listed for various simple
PrimeAngle

Radius of Gyration (r) 0.489 In 0.769 In spans, that is, a beam on two supports. If load is concentrated at
System

Axis 2-2 the center of the span, multiply load from the table by 0.5 and
Moment of Inertia (I) 0.203 In4 0.407 In4 corresponding deflection by 0.8.
Section Modulus (S) 0.250 In3 0.501 In3 4. See page 61 for lateral bracing reduction charts.
Radius of Gyration (r) 0.638 In 0.638 In 5. For Pierced Channel, Beam Load Values in the tables are multiplied
by the following factor:
Product
Index

"T" Series ... 85% "KO" Series .. 95%


"SL" Series ... 85% "HS" Series .. 90%

15⁄8" Framing System 41


® P3000 & P3001 Channels

BEAM LOADING – P3000 (METRIC) BEAM LOADING – P3001 (METRIC)


Channel
15⁄8"

Max Defl. at Max Defl. at


Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360
Telestrut
System

mm kg mm kg kg kg mm kg mm kg kg kg
600 590 2 590 590 590 600 1,343 * 1 1,343 * 1,343 * 1,343 *
750 472 3 472 472 390 750 1,329 1 1,329 1,329 1,329
Hardware

1,000 354 4 354 331 222 1,000 998 3 998 998 998
Nuts &

1,250 281 7 281 213 141 1,250 798 4 798 798 699
1,500 236 10 195 145 100 1,500 662 6 662 662 485
1,750 204 14 145 109 73 1,750 572 8 572 535 354
General
Fittings

2,000 177 18 109 82 54 2,000 499 10 499 408 272


2,500 141 28 73 54 36 2,500 399 16 349 263 172
3,000 118 40 50 36 23 3,000 331 23 240 181 122
3,500 100 54 36 27 18 3,500 286 31 177 132 91
Pipe/Conduit
Supports

4,000 91 73 27 23 14 4,000 249 41 136 104 68


4,500 77 89 23 18 NR 4,500 222 52 109 82 54
5,000 73 115 18 14 NR 5,000 200 64 86 64 45
6,000 59 161 NR NR NR 6,000 168 92 59 45 32
Electrical
Fittings

COLUMN LOADING – P3000 (METRIC) COLUMN LOADING – P3001 (METRIC)


Maximum Maximum
Unbraced Allowable Load Maximum Column Load Applied at C.G. Unbraced Allowable Load Maximum Column Load Applied at C.G.
Concrete
Inserts

Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
mm kg kg kg kg kg mm kg kg kg kg kg
600 1,447 4,418 4,100 3,683 3,302 600 2,604 9,897 9,639 9,294 8,977
750 1,388 4,073 3,683 3,216 2,817 750 2,576 9,616 9,294 8,899 8,568
11⁄4" Framing
System

1,000 1,279 3,520 3,075 2,581 2,177 1,000 2,536 9,158 8,782 8,382 7,598
1,250 1,161 3,039 2,581 2,091 1,706 1,250 2,504 8,754 8,382 7,384 6,305
1,500 1,052 2,635 2,177 1,706 1,383 1,500 2,427 8,423 7,598 6,305 5,021
1,750 957 2,295 1,842 1,429 1,125 1,750 2,322 7,856 6,740 5,230 3,828
2,000 871 2,000 1,583 1,216 862 2,000 2,182 7,171 5,874 4,214 2,930
⁄16" Framing

2,250 798 1,755 1,383 980 ** 2,250 2,028 6,468 5,021 3,334 2,318
System

2,500 735 1,556 1,216 ** ** 2,500 1,855 5,765 4,214 2,703 1,878
2,750 653 1,393 1,025 ** ** 2,750 1,683 5,076 3,488 2,232 **
13

Notes:
ELEMENTS OF SECTION
Fiberglass
System

* Load limited by spot weld shear.


P3000/P3001 (METRIC) ** KL⁄r > 200
Parameter P3000 P3001 NR = Not Recommended.

Area of Section 3.23 cm 2


6.45 cm 2 1. Above loads include the weight of the member. This weight must be
Special
Metals

deducted to arrive at the net allowable load the beam will support.
Axis 1-1
2. Long span beams should be supported in such a manner as to
Moment of Inertia (I) 4.97 cm4 24.61 cm4 prevent rotation and twist.
Section Modulus (S) 2.51 cm3 7.05 cm3 3. Allowable uniformly distributed loads are listed for various simple
PrimeAngle

Radius of Gyration (r) 1.24 cm 1.95 cm spans, that is, a beam on two supports. If load is concentrated at
System

Axis 2-2 the center of the span, multiply load from the table by 0.5 and
Moment of Inertia (I) 8.47 cm4 16.93 cm4 corresponding deflection by 0.8.
Section Modulus (S) 4.10 cm3 8.20 cm3 4. See page 61 for lateral bracing reduction charts.
5. For Pierced Channel, Beam Load Values in the tables are multiplied
Radius of Gyration (r) 1.62 cm 1.62 cm
by the following factor:
Product
Index

"T" Series ... 85% "KO" Series .. 95%


"SL" Series ... 85% "HS" Series .. 90%

42 15⁄8" Framing System


P3300 & P3301 Channels

P3300 Wt/100 Ft: 134 Lbs (200 kg/100 m)

Channel
Allowable Moment 1,800 In-Lbs (200 N•m)

15⁄8"
12 Gauge Nominal Thickness .105" (2.7mm)
1 5⁄8" 41.3
7 22.2
3 ⁄8" 3
⁄8" ⁄8" 9.5 9.5

Telestrut
System
9 7.1
⁄32"
.517" 13.1
7
1 ⁄8" 1 22.2

Hardware
9.1

Nuts &
.358" 2 2

P3301 Wt/100 Ft: 269 Lbs (400 kg/100 m)

General
Allowable Moment 5,060 In-Lbs (570 N•m)

Fittings
12 Gauge Nominal Thickness .105" (2.7mm)

1 5⁄8" 41.3

Pipe/Conduit
Supports
1 3⁄4" 44.5
1 1

Electrical
2 2

Fittings
P3300 HS P3300 T

Concrete
Inserts
Wt/100 Ft: 130 Lbs (193 kg/100 m) Wt/100 Ft: 130 Lbs (193 kg/100 m)

11⁄4" Framing
Slots are

System
9⁄16"(14.3) Dia. Holes 11⁄8" (28.6) x 9⁄16" (14.3) 1 3⁄16"
1 7⁄8" (47.6) on Center 2" (51) on Center
7
⁄8"
(30.2)
(22.2)

Framing
P3300 SL P3301 T

System
Wt/100 Ft: 130 Lbs (193 kg/100 m) Wt/100 Ft: 270 Lbs (402 kg/100 m)

13⁄16"
Fiberglass
Slots are Slots are

System
3" (76.2) x 13⁄32" (10.3) 11⁄8" (28.6) x 9⁄16" (14.3)
4" (101.6) on Center 1" 2" (51) on Center 1 3⁄16"
1
⁄2" (25.4) 7
⁄8 " (30.2)
(12.7) (22.2)
Special
Metals

Channel Nuts (Refer to Hardware Section for Details)


P4006-0832 P4012S P3006-0832 P3016-0632
PrimeAngle

P4006-1024 P4023S P3006-1024 P3016-0832


System

P4006-1420 UNISTRU P3006-1420 P3016-1024


T
P4006T1420
P4007 RU
T
P3007 P3016-1420
UNIST
P4008T
P4008 P3008
P4010T
P4009 P4012 P3009
P4010 P4023 P3013
Product
Index

Channel Finishes: PL, GR, HG, PG; Standard Lengths: 10' & 20'

15⁄8" Framing System 43


® P3300 & P3301 Channels

BEAM LOADING – P3300 BEAM LOADING – P3301


Channel
15⁄8"

Max Defl. at Max Defl. at


Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360
Telestrut
System

In Lbs In Lbs Lbs Lbs In Lbs In Lbs Lbs Lbs


24 600 0.10 600 600 400 24 1,690 0.06 1,690 1,690 1,690
36 400 0.22 360 270 180 36 1,130 0.13 1,130 1,130 860
48 300 0.40 200 150 100 48 840 0.23 840 720 480
Hardware
Nuts &

60 240 0.62 130 100 60 60 680 0.37 620 460 310


72 200 0.89 90 70 40 72 560 0.52 430 320 210
84 170 1.20 70 50 30 84 480 0.71 310 240 160
General

96 150 1.59 50 40 30 96 420 0.93 240 180 120


Fittings

108 130 1.96 40 30 20 108 380 1.20 190 140 100


120 120 2.48 30 20 20 120 340 1.47 150 120 80
144 280 2.09 110 80 50
Pipe/Conduit
Supports
Electrical
Fittings

COLUMN LOADING – P3300 COLUMN LOADING – P3301


Maximum Maximum
Unbraced Allowable Load Maximum Column Load Applied at C.G. Unbraced Allowable Load Maximum Column Load Applied at C.G.
Concrete
Inserts

Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
In Lbs Lbs Lbs Lbs Lbs In Lbs Lbs Lbs Lbs Lbs
24 2,360 7,740 7,260 6,350 5,390 24 4,290 16,990 16,580 15,770 14,720
36 2,120 6,470 5,390 3,990 2,810 36 4,150 15,890 14,720 12,980 11,120
11⁄4" Framing
System

48 1,760 4,910 3,550 2,270 1,580 48 3,940 14,160 12,360 9,880 7,510
60 1,380 3,440 2,270 1,460 ** 60 3,650 12,210 9,880 6,940 4,820
72 1,080 2,390 1,580 ** ** 72 3,270 10,190 7,510 4,820 3,350
84 2,800 8,220 5,530 3,540 **
96 2,410 6,420 4,240 ** **
⁄16" Framing

108 2,080 5,070 3,350 ** **


System
13
Fiberglass

Notes:
ELEMENTS OF SECTION
System

* Load limited by spot weld shear.


P3300/P3301 ** KL⁄r > 200
Parameter P3300 P3301 1. Above loads include the weight of the member. This weight must
be deducted to arrive at the net allowable load the beam will
Area of Section 0.395 In2 0.790 In2
Special
Metals

support.
Axis 1-1 2. Long span beams should be supported in such a manner as to
Moment of Inertia (I) 0.037 In4 0.176 In4 prevent rotation and twist.
Section Modulus (S) 0.072 In3 0.201 In3 3. Allowable uniformly distributed loads are listed for various simple
PrimeAngle

Radius of Gyration (r) 0.306 In 0.472 In spans, that is, a beam on two supports. If load is concentrated at
System

the center of the span, multiply load from the table by 0.5 and
Axis 2-2
corresponding deflection by 0.8.
Moment of Inertia (I) 0.143 In4 0.285 In4
4. See page 61 for lateral bracing reduction charts.
Section Modulus (S) 0.176 In3 0.351 In3 5. For Pierced Channel, Beam Load Values in the tables are
Radius of Gyration (r) 0.601 In 0.601 In multiplied by the following factor:
Product
Index

"T" Series ... 85% "KO" Series .. 95%


"SL" Series ... 85% "HS" Series .. 90%

44 15⁄8" Framing System


P3300 & P3301 Channels

BEAM LOADING – P3300 (METRIC) BEAM LOADING – P3301 (METRIC)

Channel
15⁄8"
Max Defl. at Max Defl. at
Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360

Telestrut
System
mm kg mm kg kg kg mm kg mm kg kg kg
600 277 2 277 277 191 600 776 1 776 776 776
750 222 4 222 181 122 750 621 2 621 621 576
1,000 168 7 136 100 68 1,000 467 4 467 467 327

Hardware
Nuts &
1,250 132 10 86 64 45 1,250 372 6 372 313 209
1,500 109 15 59 45 32 1,500 313 9 290 218 145
1,750 95 21 45 32 23 1,750 268 12 213 159 104

General
2,000 82 27 32 27 18 2,000 231 16 163 122 82

Fittings
2,500 68 43 23 18 9 2,500 186 25 104 77 50
3,000 54 60 14 9 9 3,000 154 36 73 54 36
3,500 45 79 9 9 NR 3,500 132 48 54 41 27

Pipe/Conduit
4,000 118 65 41 32 18

Supports
Electrical
Fittings
COLUMN LOADING – P3300 (METRIC) COLUMN LOADING – P3301 (METRIC)
Maximum Maximum
Unbraced Allowable Load Maximum Column Load Applied at C.G. Unbraced Allowable Load Maximum Column Load Applied at C.G.

Concrete
Inserts
Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
mm kg kg kg kg kg mm kg kg kg kg kg
600 1,075 3,524 3,320 2,917 2,486 600 1,946 7,720 7,539 7,185 6,727
750 1,030 3,293 2,917 2,381 1,860 750 1,923 7,521 7,185 6,600 5,951

11⁄4" Framing
System
1,000 925 2,740 2,204 1,533 1,066 1,000 1,860 6,999 6,391 5,493 4,568
1,250 780 2,159 1,533 980 680 1,250 1,778 6,337 5,493 4,341 3,252
1,500 640 1,615 1,066 680 ** 1,500 1,669 5,611 4,568 3,252 2,259
1,750 522 1,184 780 ** ** 1,750 1,533 4,858 3,674 2,386 1,660
2,000 1,361 4,114 2,858 1,828 **

Framing
2,250 1,202 3,406 2,259 1,442 **

System
2,500 1,057 2,771 1,828 ** **

13⁄16"
2,750 939 2,291 1,510 ** **

Fiberglass
Notes:
ELEMENTS OF SECTION

System
* Load limited by spot weld shear.
P3300/P3301 (METRIC) ** KL⁄r > 200
Parameter P3300 P3301 1. Above loads include the weight of the member. This weight must
be deducted to arrive at the net allowable load the beam will
Area of Section 2.55 cm2 5.10 cm2
Special
Metals

support.
Axis 1-1 2. Long span beams should be supported in such a manner as to
Moment of Inertia (I) 1.54 cm4 7.33 cm4 prevent rotation and twist.
Section Modulus (S) 1.18 cm3 3.30 cm3 3. Allowable uniformly distributed loads are listed for various simple
PrimeAngle

Radius of Gyration (r) 0.78 cm 1.20 cm spans, that is, a beam on two supports. If load is concentrated at
System

Axis 2-2 the center of the span, multiply load from the table by 0.5 and
corresponding deflection by 0.8.
Moment of Inertia (I) 5.94 cm4 11.87 cm4
4. See page 61 for lateral bracing reduction charts.
Section Modulus (S) 2.88 cm3 5.75 cm3
5. For Pierced Channel, Beam Load Values in the tables are
Radius of Gyration (r) 1.53 cm 1.53 cm multiplied by the following factor:
Product
Index

"T" Series ... 85% "KO" Series .. 95%


"SL" Series ... 85% "HS" Series .. 90%

15⁄8" Framing System 45


® P4000 & P4001 Channels

P4000 Wt/100 Ft: 83 Lbs (123 kg/100 m)


Channel

Allowable Moment 1,230 In-Lbs (140 N•m)


15⁄8"

41.3 16 Gauge Nominal Thickness .060" (1.5mm)


1 5⁄8"
7 22.2
3
⁄8" ⁄8" 3
⁄8" 9.5 9.5
1 6.4
Telestrut

⁄4"
System

13 .470" 11.9
⁄16" 20.6

1 1
Hardware

.343" 8.7
Nuts &

2 2

P4001
General

Wt/100 Ft: 166 Lbs (246 kg/100 m)


Fittings

Allowable Moment 3,210 In-Lbs (360 N•m)


16 Gauge Nominal Thickness .060" (1.5mm)

1 5⁄ 8" 41.3
Pipe/Conduit
Supports

1 5⁄8" 41.3
1 1
Electrical
Fittings

2 2
Concrete
Inserts

P4000 HS P4000 T
Wt/100 Ft: 79 Lbs (118 kg/100 m) Wt/100 Ft: 79 Lbs (118 kg/100 m)
11⁄4" Framing
System

9⁄16"
Slots are
(14.3) Dia. Holes
7⁄8"
11⁄8" (28.6) x 9⁄16" (14.3) 1 3⁄16"
1 (47.6) on Center
2" (51) on Center
7
⁄8" (30.2)
(22.2)
⁄16" Framing
System

P4000 SL
Wt/100 Ft: 79 Lbs (118 kg/100 m)
13
Fiberglass
System

Slots are
3" (76.2) x 13⁄32" (10.3)
4" (101.6) on Center 1"
1
⁄2" (25.4)
(12.7)
Special
Metals

Channel Nuts (Refer to Hardware Section for Details)


P4006-0832 P4012S P3006-0832 P3016-0632
PrimeAngle

P4006-1024 P4023S P3006-1024 P3016-0832


System

P4006-1420 UNISTRU P3006-1420 P3016-1024


T
P4006T1420
P4007 RU
T
P3007 P3016-1420
P4008T
UNIST

P4008 P3008
P4010T
P4009 P4012 P3009
P4010 P4023 P3013
Product
Index

Channel Finishes: PL, GR, HG, PG; Standard Lengths: 10' & 20'

46 15⁄8" Framing System


P4000 Channel Combinations

P4003 Wt/100 Ft: 248 Lbs (370 kg/100 m)

Channel
Allowable Moment 8,600 In-Lbs (970 N•m)

15⁄8"
16 Gauge Nominal Thickness .060" (1.5mm)

Telestrut
1 5⁄8" 41.3

System
1.240" 31.5

Hardware
7
2 ⁄16" 1 61.9 1

Nuts &
1.198" 30.4

2 2

General
Fittings
Pipe/Conduit
Supports
P4004 Wt/100 Ft: 331 Lbs (493 kg/100 m)
Allowable Moment 13,650 In-Lbs (1,540 N•m)
16 Gauge Nominal Thickness .060" (1.5mm)

Electrical
Fittings
1 5⁄8" 41.3

Concrete
Inserts
3 1⁄4" 1 82.6 1

11⁄4" Framing
System
2 2

Framing
System
13⁄16"
Fiberglass
System
Special
Metals
PrimeAngle
System
Product
Index

15⁄8" Framing System 47


® P4000 & P4001 Channels

BEAM LOADING – P4000 BEAM LOADING – P4001


Channel
15⁄8"

Max Defl. at Max Defl. at


Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360
Telestrut
System

In Lbs In Lbs Lbs Lbs In Lbs In Lbs Lbs Lbs


24 410 0.11 410 370 250 24 810 * 0.05 810 * 810 * 810 *
36 270 0.24 220 170 110 36 710 0.14 710 710 500
48 200 0.43 120 90 60 48 540 0.25 540 430 280
Hardware
Nuts &

60 160 0.67 80 60 40 60 430 0.40 360 270 180


72 140 1.01 60 40 30 72 360 0.57 250 190 130
84 120 1.38 40 30 20 84 310 0.78 190 140 90
96 100 1.72 30 20 20 96 270 1.02 140 110 70
General
Fittings

108 90 2.20 20 20 10 108 240 1.29 110 80 60


120 80 2.68 20 10 10 120 210 1.54 90 70 50
144 180 2.29 60 50 30
Pipe/Conduit
Supports
Electrical
Fittings

COLUMN LOADING – P4000 COLUMN LOADING – P4001


Maximum Maximum
Unbraced Allowable Load Maximum Column Load Applied at C.G. Unbraced Allowable Load Maximum Column Load Applied at C.G.
Concrete
Inserts

Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
In Lbs Lbs Lbs Lbs Lbs In Lbs Lbs Lbs Lbs Lbs
24 1,630 4,670 4,290 3,780 3,310 24 2,830 10,390 10,000 9,470 8,960
36 1,450 3,840 3,310 2,460 1,730 36 2,740 9,530 8,960 7,870 6,700
11⁄4" Framing
System

48 1,160 3,030 2,190 1,400 970 48 2,590 8,620 7,480 5,910 4,440
60 870 2,120 1,400 900 ** 60 2,340 7,380 5,910 4,090 2,840
72 670 1,470 970 ** ** 72 2,020 6,110 4,440 2,840 1,970
84 1,700 4,880 3,260 2,090 **
96 1,440 3,780 2,500 ** **
⁄16" Framing

108 1,230 2,990 1,970 ** **


System
13

Notes:
ELEMENTS OF SECTION
Fiberglass
System

* Load limited by spot weld shear.


P4000/P4001 ** KL⁄r > 200
Parameter P4000 P4001 1. Above loads include the weight of the member. This weight must be
2 2
deducted to arrive at the net allowable load the beam will support.
Area of Section 0.244 In 0.487 In
Special
Metals

2. Long span beams should be supported in such a manner as to


Axis 1-1 prevent rotation and twist.
Moment of Inertia (I) 0.023 In4 0.104 In4 3. Allowable uniformly distributed loads are listed for various simple
Section Modulus (S) 0.049 In3 0.128 In3 spans, that is, a beam on two supports. If load is concentrated at
PrimeAngle

Radius of Gyration (r) 0.306 In 0.462 In the center of the span, multiply load from the table by 0.5 and
System

corresponding deflection by 0.8.


Axis 2-2
4. See page 61 for lateral bracing reduction charts.
Moment of Inertia (I) 0.092 In4 0.183 In4
5. For Pierced Channel, Reduce Beam Load Values as Follows:
Section Modulus (S) 0.113 In3 0.225 In3
"T" Series ... 85% "SL" Series .. 85%
Radius of Gyration (r) 0.613 In 0.613 In "HS" Series ... 90%
Product
Index

48 15⁄8" Framing System


P4000 & P4001 Channels

BEAM LOADING – P4000 (METRIC) BEAM LOADING – P4001 (METRIC)

Channel
15⁄8"
Max Defl. at Max Defl. at
Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360

Telestrut
System
mm kg mm kg kg kg mm kg mm kg kg kg
600 191 3 191 177 118 600 367 * 1 367 * 367 * 367 *
750 150 4 150 113 73 750 367 * 2 367 * 367 * 340
1,000 113 8 82 64 41 1,000 295 4 295 286 191

Hardware
Nuts &
1,250 91 12 54 41 27 1,250 236 7 236 181 122
1,500 77 17 36 27 18 1,500 200 10 168 127 86
1,750 64 23 27 23 14 1,750 168 13 127 95 64
2,000 54 29 23 14 9 2,000 150 17 95 73 50

General
Fittings
2,500 45 47 14 9 5 2,500 118 27 59 45 32
3,000 36 65 9 9 5 3,000 100 39 41 32 23
3,500 86 54 32 23 14

Pipe/Conduit
Supports
Electrical
Fittings
COLUMN LOADING – P4000 (METRIC) COLUMN LOADING – P4001 (METRIC)
Maximum Maximum
Unbraced Allowable Load Maximum Column Load Applied at C.G. Unbraced Allowable Load Maximum Column Load Applied at C.G.

Concrete
Inserts
Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
mm kg kg kg kg kg mm kg kg kg kg kg
600 739 2,132 1,960 1,733 1,524 600 1,288 4,726 4,550 4,314 4,082
750 708 1,946 1,733 1,470 1,148 750 1,266 4,536 4,314 4,028 3,611

11⁄4" Framing
System
1,000 626 1,642 1,356 943 658 1,000 1,229 4,214 3,892 3,320 2,740
1,250 508 1,329 943 603 422 1,250 1,166 3,856 3,320 2,595 1,914
1,500 404 993 658 422 ** 1,500 1,070 3,393 2,740 1,914 1,329
1,750 327 730 481 ** ** 1,750 957 2,921 2,177 1,406 975
2,000 830 2,454 1,683 1,075 **

Framing
2,250 726 2,014 1,329 853 **

System
2,500 630 1,633 1,075 ** **

13⁄16"
2,750 553 1,347 889 ** **

Notes:
ELEMENTS OF SECTION
Fiberglass
System
* Load limited by spot weld shear.
P4000/P4001 (METRIC) ** KL⁄r > 200
Parameter P4000 P4001 1. Above loads include the weight of the member. This weight must be
2 2
deducted to arrive at the net allowable load the beam will support.
Area of Section 1.57 cm 3.14 cm
Special
Metals

2. Long span beams should be supported in such a manner as to


Axis 1-1 prevent rotation and twist.
Moment of Inertia (I) 0.95 cm4 4.32 cm4 3. Allowable uniformly distributed loads are listed for various simple
Section Modulus (S) 0.80 cm3 2.09 cm3 spans, that is, a beam on two supports. If load is concentrated at
PrimeAngle

Radius of Gyration (r) 0.78 cm 1.17 cm the center of the span, multiply load from the table by 0.5 and
System

corresponding deflection by 0.8.


Axis 2-2
4. See page 61 for lateral bracing reduction charts.
Moment of Inertia (I) 3.81 cm4 7.62 cm4
5. For Pierced Channel, Reduce Beam Load Values as Follows:
Section Modulus (S) 1.85 cm3 3.69 cm3
"T" Series ... 85% "SL" Series .. 85%
Radius of Gyration (r) 1.56 cm 1.56 cm "HS" Series ... 90%
Product
Index

15⁄8" Framing System 49


® P4100 & P4101 Channels

P4100 Wt/100 Ft: 98 Lbs (147 kg/100 m)


Channel

Allowable Moment 1,360 In-Lbs (150 N•m)


15⁄8"

14 Gauge Nominal Thickness .075" (1.9mm)

1 5⁄8" 41.3
7
⁄8" 22.2
Telestrut

3 3
System

⁄8" ⁄8" 9.5 9.5


1
⁄4" 6.4
.480" 12.2

1 1
Hardware

20.6
Nuts &

13
⁄16" 8.4
2 .333" 2
General
Fittings

P4101 Wt/100 Ft: 197 Lbs (293 kg/100 m)


Allowable Moment 3,610 In-Lbs (410 N•m)
14 Gauge Nominal Thickness .075" (1.9mm)
Pipe/Conduit

1 5⁄8" 41.3
Supports

13 20.6
⁄16"

1
1 5⁄8" 1 41.3
Electrical
Fittings

13
⁄16" 20.6
2 2
Concrete
Inserts

P4100 HS P4100 T
Wt/100 Ft: 87 Lbs (129 kg/100 m) Wt/100 Ft: 87 Lbs (129 kg/100 m)
11⁄4" Framing
System

9⁄16" (14.3) Dia. Holes Slots are


7⁄8" 11⁄8" (28.6) x 9⁄16" (14.3)
1 (47.6) on Center
7
1 3⁄16"
2" (51) on Center ⁄8" (30.2)
(22.2)
⁄16" Framing
System

P4100 SL P4101 T
Wt/100 Ft: 87 Lbs (129 kg/100 m) Wt/100 Ft: 174 Lbs (259 kg/100 m)
13
Fiberglass
System

Slots are
3" (76.2) x 13⁄32" (10.3) Slots are
4" (101.6) on Center 1" 11⁄8" (28.6) x 9⁄16" (14.3)
1
⁄2" (25.4) 2" (51) on Center 1 3⁄16"
(12.7) 7
⁄8" (30.2)
Special
Metals

(22.2)

Channel Nuts (Refer to Hardware Section for Details)


P4006-0832 P4012S P3006-0832 P3016-0632
PrimeAngle

P4006-1024 P4023S P3006-1024 P3016-0832


System

P4006-1420 UNISTRU P3006-1420 P3016-1024


T
P4006T1420
P4007 RU
T
UNIST P3007 P3016-1420
P4008T
P4008 P3008
P4010T
P4009 P4012 P3009
P4010 P4023 P3013
Product
Index

Channel Finishes: PL, GR, HG, PG; Standard Lengths: 10' & 20'

50 15⁄8" Framing System


P4100 & P4101 Channels

BEAM LOADING – P4100 BEAM LOADING – P4101

Channel
15⁄8"
Max Defl. at Max Defl. at
Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360

Telestrut
System
In Lbs In Lbs Lbs Lbs In Lbs In Lbs Lbs Lbs
24 450 0.11 450 420 280 24 1,090 * 0.06 1,090 * 1,090 * 1,090 *
36 300 0.24 250 190 130 36 800 0.14 800 800 570
48 230 0.44 140 110 70 48 600 0.25 600 480 320

Hardware
Nuts &
60 180 0.67 90 70 50 60 480 0.39 410 310 200
72 150 0.96 60 50 30 72 400 0.57 280 210 140
84 130 1.32 50 30 20 84 340 0.76 210 160 100

General
96 110 1.67 40 30 20 96 300 1.00 160 120 80

Fittings
108 100 2.16 30 20 10 108 270 1.29 130 90 60
120 90 2.67 20 20 10 120 240 1.57 100 80 50
144 80 4.09 20 NR NR 144 200 2.26 70 50 40

Pipe/Conduit
168 60 4.88 NR NR NR 168 170 3.05 50 40 30

Supports
192 60 7.28 NR NR NR 192 150 4.02 40 NR NR
216 50 8.64 NR NR NR 216 130 4.96 NR NR NR
240 50 11.85 NR NR NR 240 120 6.28 NR NR NR

Electrical
Fittings
COLUMN LOADING – P4100 COLUMN LOADING – P4101
Maximum Maximum
Unbraced Allowable Load Maximum Column Load Applied at C.G. Unbraced Allowable Load Maximum Column Load Applied at C.G.

Concrete
Inserts
Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
In Lbs Lbs Lbs Lbs Lbs In Lbs Lbs Lbs Lbs Lbs
24 1,840 5,610 5,210 4,570 3,850 24 3,240 12,370 11,950 11,370 10,540
36 1,640 4,660 3,850 2,800 1,960 36 3,120 11,470 10,540 9,160 7,720

11⁄4" Framing
System
48 1,310 3,490 2,480 1,590 1,100 48 2,940 10,090 8,680 6,770 4,980
60 1,000 2,400 1,590 ** ** 60 2,680 8,560 6,770 4,590 3,190
72 770 1,670 1,100 ** ** 72 2,310 7,010 4,980 3,190 2,220
84 1,950 5,530 3,660 2,340 **
96 1,650 4,250 2,800 ** **

Framing
System
108 1,410 3,360 2,220 ** **

13⁄16"
Notes:
ELEMENTS OF SECTION
Fiberglass
System
* Load limited by spot weld shear.
P4100/P4101 ** KL⁄r > 200
1. Above loads include the weight of the member. This weight must be
Parameter P4100 P4101 deducted to arrive at the net allowable load the beam will support.
Special
Metals

2. Long span beams should be supported in such a manner as to


Area of Section 0.290 In2 0.579 In2 prevent rotation and twist.
Axis 1-1 3. Allowable uniformly distributed loads are listed for various simple
Moment of Inertia (I) 0.026 In4 0.117 In4 spans, that is, a beam on two supports. If load is concentrated at
PrimeAngle

Section Modulus (S) 0.054 In3 0.143 In3 the center of the span, multiply load from the table by 0.5 and
System

corresponding deflection by 0.8.


Radius of Gyration (r) 0.298 In 0.449 In
4. See page 61 for lateral bracing reduction charts.
Axis 2-2
5. For Pierced Channel, Beam Load Values in the tables are multiplied
Moment of Inertia (I) 0.107 In4 0.214 In4
by the following factor:
Section Modulus (S) 0.132 In3 0.264 In3 "T" Series ... 85% "SL" Series .. 85%
Product

Radius of Gyration (r) 0.609 In 0.608 In


Index

"HS" Series ... 90%

15⁄8" Framing System 51


® P4100 & P4101 Channels

BEAM LOADING – P4100 (METRIC) BEAM LOADING – P4101 (METRIC)


Channel
15⁄8"

Max Defl. at Max Defl. at


Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360
Telestrut
System

mm kg mm kg kg kg mm kg mm kg kg kg
600 209 3 209 200 132 600 494 * 1 494 * 494 * 494 *
750 168 4 168 127 86 750 445 2 445 445 381
1,000 127 7 95 73 45 1,000 331 4 331 322 213
Hardware
Nuts &

1,250 100 11 59 45 32 1,250 268 7 268 204 136


1,500 82 16 41 32 23 1,500 222 10 191 145 95
1,750 73 23 32 23 14 1,750 191 13 141 104 68
2,000 64 30 23 18 14 2,000 168 17 109 82 54
General
Fittings

2,500 50 46 14 14 9 2,500 132 27 68 50 36


3,000 41 65 9 9 5 3,000 109 38 50 36 23
3,500 95 53 36 27 18
Pipe/Conduit
Supports
Electrical
Fittings

COLUMN LOADING – P4100 (METRIC) COLUMN LOADING – P4101 (METRIC)


Maximum Maximum
Unbraced Allowable Load Maximum Column Load Applied at C.G. Unbraced Allowable Load Maximum Column Load Applied at C.G.
Concrete
Inserts

Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
mm kg kg kg kg kg mm kg kg kg kg kg
600 835 2,558 2,377 2,100 1,778 600 1,470 5,620 5,439 5,185 4,817
750 798 2,363 2,100 1,696 1,306 750 1,451 5,425 5,185 4,717 4,205
11⁄4" Framing
System

1,000 708 1,964 1,565 1,070 744 1,000 1,397 5,035 4,554 3,851 3,139
1,250 576 1,529 1,070 685 476 1,250 1,324 4,509 3,851 2,966 2,150
1,500 463 1,125 744 476 ** 1,500 1,225 3,942 3,139 2,150 1,492
1,750 372 826 544 ** ** 1,750 1,093 3,361 2,463 1,579 1,098
2,000 953 2,794 1,891 1,211 **
⁄16" Framing

2,250 830 2,263 1,492 957 **


System
13

Notes:
Fiberglass

ELEMENTS OF SECTION
System

* Load limited by spot weld shear.


P4100/P4101 ** KL⁄r > 200
Parameter P4100 P4101 1. Above loads include the weight of the member. This weight must be
2 2 deducted to arrive at the net allowable load the beam will support.
Area of Section 1.87 cm 3.74 cm
Special
Metals

2. Long span beams should be supported in such a manner as to


Axis 1-1 prevent rotation and twist.
Moment of Inertia (I) 1.07 cm4 4.85 cm4 3. Allowable uniformly distributed loads are listed for various simple
Section Modulus (S) 0.88 cm3 2.35 cm3 spans, that is, a beam on two supports. If load is concentrated at
PrimeAngle

Radius of Gyration (r) 0.76 cm 1.14 cm the center of the span, multiply load from the table by 0.5 and
System

Axis 2-2 corresponding deflection by 0.8.


4. See page 61 for lateral bracing reduction charts.
Moment of Inertia (I) 4.46 cm4 8.93 cm4
5. For Pierced Channel, Beam Load Values in the tables are multiplied
Section Modulus (S) 2.16 cm3 4.32 cm3
by the following factor:
Radius of Gyration (r) 1.55 cm 1.55 cm
"T" Series ... 85% "SL" Series .. 85%
Product
Index

"HS" Series ... 90%

52 15⁄8" Framing System


P5000 & P5001 Channels

P5000 1 5⁄8" 41.3 Wt/100 Ft: 305 Lbs (454 kg/100 m)

Channel
Allowable Moment 15,770 In-Lbs (1,780 N•m)

15⁄8"
7 22.2
3 ⁄8" 3 9.5 9.5 12 Gauge Nominal Thickness .105" (2.7mm)
⁄8" ⁄8"

Telestrut
System
9
⁄32" 1.750" 7.1 44.5

3 1⁄4" 82.6 1
1

38.1

Hardware
1.500"

Nuts &
2 2

General
Fittings
P5001 Wt/100 Ft: 610 Lbs (907 kg/100 m)
1 5⁄8" 41.3 Allowable Moment 48,180 In-Lbs (5,440 N•m)
12 Gauge Nominal Thickness .105" (2.7mm)

Pipe/Conduit
Supports
6 1⁄2" 165.1

1 1

Electrical
Fittings
Concrete
Inserts
2 2

P5000 HS P5000 KO
Wt/100 Ft: 300 Lbs (446 kg/100 m) Wt/100 Ft: 305 Lbs (454 kg/100 m)

11⁄4" Framing
System
7
9⁄16"
(14.3) Dia. Holes ⁄8" (22.2) Knockouts

Framing
1 7⁄8" (47.6) on Center 6" (152.4) on Center

System
P5000 SL P5000 T
Wt/100 Ft: 300 Lbs (446 kg/100 m) Wt/100 Ft: 300 Lbs (446 kg/100 m)

13⁄16"
Slots are
3" (76.2) x 13⁄32" (10.3) Slots are
4" (101.6) on Center 11⁄8" (28.6) x 9⁄16" (14.3)

Fiberglass
System
2" (51) on Center

1" 7 1 3⁄16"
1
⁄2" ⁄8"
Special

(30.2)
Metals

(25.4) (22.2)
(12.7)
Channel Nuts (Refer to Hardware Section for Details)
P1006T1420 P1012 P3006-0832 P3016-0632
PrimeAngle

UNISTRU
T
System

P1008T P1023 P3006-1024 P3016-0832


T
RU
UNIST

P1010T P1024 P3006-1420 P3016-1024


P3007 P3016-1420
P3008
P3009
P3010
Product
Index

Channel Finishes: PL, GR, HG, PG; Standard Lengths: 10' & 20'

15⁄8" Framing System 53


® P5000 & P5001 Channels

BEAM LOADING – P5000 BEAM LOADING – P5001


Channel
15⁄8"

Max Defl. at Max Defl. at


Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360
Telestrut
System

In Lbs In Lbs Lbs Lbs In Lbs In Lbs Lbs Lbs


24 5,260 0.03 5,260 5,260 5,260 24 6,890 * 0.01 6,890 * 6,890 * 6,890 *
36 3,500 0.07 3,500 3,500 3,500 36 6,890 * 0.02 6,890 * 6,890 * 6,890 *
48 2,630 0.12 2,630 2,630 2,630 48 6,890 * 0.05 6,890 * 6,890 * 6,890 *
Hardware
Nuts &

60 2,100 0.18 2,100 2,100 1,920 60 6,420 0.10 6,420 6,420 6,420
72 1,750 0.26 1,750 1,750 1,330 72 5,350 0.14 5,350 5,350 5,350
84 1,500 0.36 1,500 1,470 980 84 4,590 0.19 4,590 4,590 4,590
General

96 1,310 0.47 1,310 1,120 750 96 4,020 0.25 4,020 4,020 4,020
Fittings

108 1,170 0.59 1,170 890 590 108 3,570 0.32 3,570 3,570 3,360
120 1,050 0.73 960 720 480 120 3,210 0.39 3,210 3,210 2,720
144 880 1.06 670 500 330 144 2,680 0.57 2,680 2,680 1,890
Pipe/Conduit

168 750 1.43 490 370 240 168 2,290 0.77 2,290 2,080 1,390
Supports

192 660 1.88 370 280 190 192 2,010 1.01 2,010 1,590 1,060
216 580 2.35 300 220 150 216 1,780 1.27 1,680 1,260 840
240 530 2.95 240 180 120 240 1,610 1.58 1,360 1,020 680
Electrical
Fittings

COLUMN LOADING – P5000 COLUMN LOADING – P5001


Maximum Maximum
Unbraced Allowable Load Maximum Column Load Applied at C.G. Unbraced Allowable Load Maximum Column Load Applied at C.G.
Concrete
Inserts

Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
In Lbs Lbs Lbs Lbs Lbs In Lbs Lbs Lbs Lbs Lbs
24 5,650 16,870 15,180 12,850 10,600 24 10,670 39,230 38,030 36,210 34,240
36 4,690 13,140 10,600 7,650 5,660 36 10,350 36,450 34,240 31,200 28,260
11⁄4" Framing

48 3,560 9,550 6,860 4,790 3,660 48 9,940 33,220 30,200 26,430 23,190
System

60 2,730 6,680 4,790 3,450 2,710 60 9,290 29,950 26,430 22,470 19,380
72 2,160 4,980 3,660 2,710 2,170 72 8,560 26,880 23,190 19,380 16,450
84 1,760 3,950 2,960 2,240 1,820 84 7,860 24,140 20,520 17,040 12,090
96 1,500 3,270 2,500 1,930 1,580 96 7,220 21,790 18,370 13,330 9,250
⁄16" Framing

108 1,310 2,800 2,170 1,690 1,390 108 6,600 19,790 16,450 10,530 7,310
System

120 1,170 2,450 1,930 1,510 ** 120 5,760 18,130 13,330 8,530 **
144 980 1,980 1,580 ** ** 144 4,390 14,020 9,250 ** **
13

168 850 1,670 1,340 ** ** 168 3,420 10,300 6,800 ** **


Notes:
Fiberglass

ELEMENTS OF SECTION
System

* Load limited by spot weld shear.


P5000/P5001 ** KL⁄r > 200
1. Above loads include the weight of the member. This weight must be
Parameter P5000 P5001
deducted to arrive at the net allowable load the beam will support.
0.897 In2 1.793 In2
Special

Area of Section
Metals

2. Long span beams should be supported in such a manner as to


Axis 1-1 prevent rotation and twist.
Moment of Inertia (I) 1.098 In4 6.227 In4 3. Allowable uniformly distributed loads are listed for various simple
Section Modulus (S) 0.627 In3 1.916 In3 spans, that is, a beam on two supports. If load is concentrated at
PrimeAngle

the center of the span, multiply load from the table by 0.5 and
Radius of Gyration (r) 1.107 In 1.864 In
System

corresponding deflection by 0.8.


Axis 2-2 4. See page 61 for lateral bracing reduction charts.
Moment of Inertia (I) 0.433 In4 0.866 In4 5. For Pierced Channel, Beam Load Values in the tables are multiplied
Section Modulus (S) 0.533 In3 1.066 In3 by the following factor:
Radius of Gyration (r) 0.695 In 0.695 In "T" Series ... 85% "KO" Series .. 95%
Product
Index

"SL" Series ... 85% "HS" Series .. 90%

54 15⁄8" Framing System


P5000 & P5001 Channels

BEAM LOADING – P5000 (METRIC) BEAM LOADING – P5001 (METRIC)

Channel
15⁄8"
Max Defl. at Max Defl. at
Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360

Telestrut
System
mm kg mm kg kg kg mm kg mm kg kg kg
600 2,422 1 2,422 2,422 2,422 600 3,125 * 0 3,125 * 3,125 * 3,125 *
750 1,937 1 1,937 1,937 1,937 750 3,125 * 0 3,125 * 3,125 * 3,125 *
1,000 1,451 2 1,451 1,451 1,451 1,000 3,125 * 1 3,125 * 3,125 * 3,125 *

Hardware
Nuts &
1,250 1,161 3 1,161 1,161 1,161 1,250 3,125 * 1 3,125 * 3,125 * 3,125 *
1,500 971 5 971 971 898 1,500 2,962 2 2,962 2,962 2,962
1,750 830 6 830 830 662 1,750 2,536 3 2,536 2,536 2,536

General
2,000 726 8 726 726 503 2,000 2,223 4 2,223 2,223 2,223

Fittings
2,500 581 12 581 485 322 2,500 1,778 7 1,778 1,778 1,778
3,000 485 18 449 336 227 3,000 1,479 10 1,479 1,479 1,275
3,500 417 25 331 249 163 3,500 1,270 13 1,270 1,270 934

Pipe/Conduit
4,000 363 32 254 191 127 4,000 1,111 17 1,111 1,075 717

Supports
4,500 322 40 200 150 100 4,500 989 22 989 848 567
5,000 290 50 163 122 82 5,000 889 27 889 689 458
6,000 240 71 113 86 54 6,000 739 39 635 476 318

Electrical
Fittings
COLUMN LOADING – P5000 (METRIC) COLUMN LOADING – P5001 (METRIC)
Maximum Maximum
Unbraced Allowable Load Maximum Column Load Applied at C.G. Unbraced Allowable Load Maximum Column Load Applied at C.G.

Concrete
Inserts
Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
mm kg kg kg kg kg mm kg kg kg kg kg
600 2,572 7,702 6,949 5,910 4,899 600 4,844 17,831 17,300 16,493 15,617
750 2,400 6,886 5,910 4,663 3,565 750 4,776 17,250 16,493 15,390 14,256

11⁄4" Framing
1,000 1,982 5,479 4,277 2,985 2,227 1,000 4,645 16,134 15,014 13,517 12,115

System
1,250 1,569 4,182 2,985 2,091 1,601 1,250 4,491 14,919 13,517 11,789 10,319
1,500 1,261 3,112 2,227 1,601 1,256 1,500 4,241 13,698 12,115 10,319 8,909
1,750 1,039 2,422 1,769 1,302 1,039 1,750 3,969 12,537 10,873 9,117 7,834
2,000 866 1,973 1,465 1,098 889 2,000 3,701 11,476 9,807 8,160 6,241

Framing
2,250 748 1,660 1,256 957 780 2,250 3,452 10,523 8,909 7,099 4,931

System
2,500 658 1,433 1,098 848 699 2,500 3,221 9,684 8,160 5,752 3,992
2,750 590 1,266 980 767 630 2,750 2,985 8,958 7,430 4,754 3,302

13⁄16"
Notes:

Fiberglass
ELEMENTS OF SECTION

System
* Load limited by spot weld shear.
P5000/P5001 (METRIC) ** KL⁄r > 200
1. Above loads include the weight of the member. This weight must be
Parameter P5000 P5001 deducted to arrive at the net allowable load the beam will support.
Special

Area of Section 5.78 cm2 11.57 cm2


Metals

2. Long span beams should be supported in such a manner as to


Axis 1-1 prevent rotation and twist.
Moment of Inertia (I) 45.70 cm4 259.17 cm4 3. Allowable uniformly distributed loads are listed for various simple
Section Modulus (S) 10.28 cm3 31.40 cm3 spans, that is, a beam on two supports. If load is concentrated at
PrimeAngle

the center of the span, multiply load from the table by 0.5 and
Radius of Gyration (r) 2.81 cm 4.73 cm
System

corresponding deflection by 0.8.


Axis 2-2 4. See page 61 for lateral bracing reduction charts.
Moment of Inertia (I) 18.02 cm4 36.04 cm4 5. For Pierced Channel, Beam Load Values in the tables are multiplied
Section Modulus (S) 8.73 cm3 17.46 cm3 by the following factor:
Radius of Gyration (r) 1.77 cm 1.77 cm "T" Series ... 85% "KO" Series .. 95%
Product
Index

"SL" Series ... 85% "HS" Series .. 90%

15⁄8" Framing System 55


® P5500 & P5501 Channels

P5500 Wt/100 Ft: 247 Lbs (367 kg/100 m)


Channel

41.3 Allowable Moment 9,820 In-Lbs (1,110 N•m)


1 5⁄8"
15⁄8"

7
⁄8" 22.2 12 Gauge Nominal Thickness .105" (2.7mm)
3
⁄8" 3
⁄8" 9.5 9.5
Telestrut
System

1.336" 33.9
9
⁄32" 7.1
7
2 ⁄16" 1 61.9 1

1.103" 28.0
Hardware
Nuts &

2 2

P5501 Wt/100 Ft: 494 Lbs (734 kg/100 m)


General
Fittings

5 41.3 Allowable Moment 28,940 In-Lbs (3,270 N•m)


1 ⁄8" 12 Gauge Nominal Thickness .105" (2.7mm)
Pipe/Conduit
Supports

4 7⁄8" 123.8
1 1
Electrical
Fittings

2 2
Concrete
Inserts

P5500 HS P5500 KO P5500 SL


Wt/100 Ft: 242 Lbs (360 kg/100 m) Wt/100 Ft: 247 Lbs (368 kg/100 m) Wt/100 Ft: 242 Lbs (360 kg/100 m)
Slots are
11⁄4" Framing

9
⁄16" (14.3) Dia. Holes 7
⁄8" (22.2) Knockouts 3" (76.2) x 13⁄32" (10.3)
System

17⁄8" (47.6) on Center 6" (152.4) on Center 4" (101.6) on Center


⁄16" Framing

1 1"
⁄2"
(25.4)
System

(12.7)

P5500 T P5501 T
13

Wt/100 Ft: 242 Lbs (360 kg/100 m) Wt/100 Ft: 494 Lbs (735 kg/100 m)
Fiberglass
System

Slots are
11⁄8" (28.6) x 9⁄16" (14.3)
Slots are 2" (51) on Center
11⁄8" (28.6) x 9⁄16" (14.3)
2" (51) on Center 7 1 3⁄16"
⁄8" 1 3⁄16" 7
⁄8" (22.2)
Special

(30.2)
Metals

(22.2) (30.2)

Channel Nuts (Refer to Hardware Section for Details)


P5506-0832 P1006T1420 P1012 P3006-0832 P3016-0632
PrimeAngle

UNISTRU
T
System

P5506-1024 P1008T P1023 P3006-1024 P3016-0832


T
RU
UNIST

P5506-1420 P1010T P1024 P3006-1420 P3016-1024


P5507 P3007 P3016-1420
P5508 P3008
P5509 P3009
P5510 P3010
Product
Index

Channel Finishes: PL, GR, HG, PG; Standard Lengths: 10' & 20'

56 15⁄8" Framing System


P5500 & P5501 Channels

BEAM LOADING – P5500 BEAM LOADING – P5501

Channel
15⁄8"
Max Defl. at Max Defl. at
Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360

Telestrut
System
In Lbs In Lbs Lbs Lbs In Lbs In Lbs Lbs Lbs
24 3,270 0.04 3,270 3,270 3,270 24 5,220 * 0.01 5,220 * 5,220 * 5,220 *
36 2,180 0.09 2,180 2,180 2,180 36 5,220 * 0.04 5,220 * 5,220 * 5,220 *
48 1,640 0.15 1,640 1,640 1,420 48 4,820 0.08 4,820 4,820 4,820

Hardware
Nuts &
60 1,310 0.24 1,310 1,310 910 60 3,860 0.13 3,860 3,860 3,860
72 1,090 0.34 1,090 950 630 72 3,220 0.19 3,220 3,220 3,220
84 940 0.47 930 700 470 84 2,760 0.26 2,760 2,760 2,500
96 820 0.61 710 530 360 96 2,410 0.34 2,410 2,410 1,920

General
Fittings
108 730 0.78 560 420 280 108 2,140 0.42 2,140 2,140 1,510
120 650 0.95 460 340 230 120 1,930 0.52 1,930 1,840 1,230
144 550 1.39 320 240 160 144 1,610 0.76 1,610 1,280 850

Pipe/Conduit
168 470 1.89 230 170 120 168 1,380 1.03 1,250 940 630

Supports
192 410 2.46 180 130 90 192 1,210 1.35 960 720 480
216 360 3.07 140 110 70 216 1,070 1.70 760 570 380
240 330 3.86 110 90 60 240 960 2.09 610 460 310

Electrical
Fittings
COLUMN LOADING – P5500 COLUMN LOADING – P5501
Maximum Maximum
Unbraced Allowable Load Maximum Column Load Applied at C.G. Unbraced Allowable Load Maximum Column Load Applied at C.G.

Concrete
Inserts
Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
In Lbs Lbs Lbs Lbs Lbs In Lbs Lbs Lbs Lbs Lbs
24 4,640 13,840 12,570 10,840 9,190 24 8,580 31,810 30,880 29,520 28,100
36 3,970 11,050 9,190 7,030 5,370 36 8,350 29,700 28,100 26,000 24,070

11⁄4" Framing
System
48 3,180 8,420 6,390 4,620 3,630 48 8,080 27,390 25,330 22,910 20,940
60 2,550 6,250 4,620 3,450 2,780 60 7,720 25,170 22,910 20,510 17,170
72 2,120 4,790 3,630 2,780 2,260 72 7,270 23,190 20,940 17,170 12,700
84 1,810 3,890 3,010 2,330 1,910 84 6,780 21,510 18,740 13,430 9,330
96 1,580 3,290 2,580 2,020 1,650 96 6,130 20,110 15,630 10,290 7,150

Framing
108 1,400 2,860 2,260 1,770 1,440 108 5,450 17,750 12,700 8,130 5,650

System
120 1,270 2,530 2,020 1,580 ** 120 4,800 15,260 10,290 6,590 **

13⁄16"
144 1,060 2,070 1,650 ** ** 144 3,760 10,830 7,150 ** **
168 920 1,750 1,380 ** ** 168 2,970 7,950 5,250 ** **

Fiberglass
System
ELEMENTS OF SECTION Notes:
* Load limited by spot weld shear.
P5500/P5501
** KL⁄r > 200
Parameter P5500 P5501
1. Above loads include the weight of the member. This weight must be
Special

Area of Section 0.726 In2 1.452 In2


Metals

deducted to arrive at the net allowable load the beam will support.
Axis 1-1 2. Long span beams should be supported in such a manner as to
Moment of Inertia (I) 0.522 In4 2.805 In4 prevent rotation and twist.
Section Modulus (S) 0.390 In3 1.151 In3 3. Allowable uniformly distributed loads are listed for various simple
PrimeAngle

Radius of Gyration (r) 0.848 In 1.390 In spans, that is, a beam on two supports. If load is concentrated at the
System

center of the span, multiply load from the table by 0.5 and corre-
Axis 2-2 sponding deflection by 0.8.
Moment of Inertia (I) 0.334 In4 0.669 In4 4. See page 61 for lateral bracing reduction charts.
Section Modulus (S) 0.411 In3 0.823 In3 5. For Pierced Channel, Beam Load Values in the tables are multiplied
Radius of Gyration (r) 0.679 In 0.679 In by the following factor:
Product
Index

"T" Series ... 85% "KO" Series .. 95%


"SL" Series ... 85% "HS" Series .. 90%

15⁄8" Framing System 57


® P5500 & P5501 Channels

BEAM LOADING – P5500 (METRIC) BEAM LOADING – P5501 (METRIC)


Channel
15⁄8"

Max Defl. at Max Defl. at


Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360
Telestrut
System

mm kg mm kg kg kg mm kg mm kg kg kg
600 1,510 1 1,510 1,510 1,510 600 2,368 * 0 2,368 * 2,368 * 2,368 *
750 1,207 1 1,207 1,207 1,207 750 2,368 * 1 2,368 * 2,368 * 2,368 *
1,000 907 3 907 907 907 1,000 2,368 * 1 2,368 * 2,368 * 2,368 *
Hardware
Nuts &

1,250 726 4 726 726 617 1,250 2,132 2 2,132 2,132 2,132
1,500 603 6 603 603 426 1,500 1,778 3 1,778 1,778 1,778
1,750 517 8 517 472 313 1,750 1,524 4 1,524 1,524 1,524
General

2,000 454 10 454 358 240 2,000 1,334 6 1,334 1,334 1,293
Fittings

2,500 363 16 308 231 154 2,500 1,066 9 1,066 1,066 826
3,000 304 24 213 159 109 3,000 889 13 889 862 576
3,500 259 32 159 118 77 3,500 762 18 762 630 422
Pipe/Conduit

4,000 227 42 118 91 59 4,000 667 23 644 485 322


Supports

4,500 200 53 95 73 45 4,500 594 29 508 381 254


5,000 181 66 77 59 36 5,000 535 36 413 308 209
6,000 150 94 54 41 27 6,000 445 52 286 213 145
Electrical
Fittings

COLUMN LOADING – P5500 (METRIC) COLUMN LOADING – P5501 (METRIC)


Maximum Maximum
Unbraced Allowable Load Maximum Column Load Applied at C.G. Unbraced Allowable Load Maximum Column Load Applied at C.G.
Concrete

Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
Inserts

mm kg kg kg kg kg mm kg kg kg kg kg
600 2,109 6,314 5,752 4,976 4,237 600 3,892 14,429 14,007 13,390 12,746
750 1,996 5,702 4,976 4,060 3,257 750 3,787 13,472 12,746 11,793 10,918
11⁄4" Framing

1,000 1,701 4,663 3,778 2,794 2,141 1,000 3,665 12,424 11,489 10,392 9,498
System

1,250 1,411 3,710 2,794 2,028 1,597 1,250 3,502 11,417 10,392 9,303 7,788
1,500 1,175 2,903 2,141 1,597 1,284 1,500 3,298 10,519 9,498 7,788 5,761
1,750 1,002 2,309 1,742 1,324 1,080 1,750 3,075 9,757 8,500 6,092 4,232
2,000 875 1,923 1,474 1,139 930 2,000 2,781 9,122 7,090 4,667 3,243
⁄16" Framing

2,250 776 1,647 1,284 998 816 2,500 2,472 8,051 5,761 3,688 2,563
System

2,500 699 1,447 1,139 889 730 3,000 2,177 6,922 4,667 2,989 **
2,750 635 1,293 1,025 803 653 3,500 1,706 4,912 3,243 ** **
13

4,000 1,347 3,606 2,381 ** **

Notes:
ELEMENTS OF SECTION
Fiberglass
System

* Load limited by spot weld shear.


P5500/P5501 (METRIC) ** KL⁄r > 200
1. Above loads include the weight of the member. This weight must be
Parameter P5500 P5501 deducted to arrive at the net allowable load the beam will support.
Special
Metals

Area of Section 4.68 cm2 9.37 cm2 2. Long span beams should be supported in such a manner as to
Axis 1-1 prevent rotation and twist.
Moment of Inertia (I) 21.71 cm4 116.76 cm4 3. Allowable uniformly distributed loads are listed for various simple
spans, that is, a beam on two supports. If load is concentrated at the
Section Modulus (S) 6.40 cm3 18.86 cm3
PrimeAngle

center of the span, multiply load from the table by 0.5 and corre-
Radius of Gyration (r) 2.15 cm 3.53 cm
System

sponding deflection by 0.8.


Axis 2-2 4. See page 61 for lateral bracing reduction charts.
Moment of Inertia (I) 13.91 cm4 27.83 cm4 5. For Pierced Channel, Beam Load Values in the tables are multiplied
Section Modulus (S) 6.74 cm3 13.48 cm3 by the following factor:
Radius of Gyration (r) 1.72 cm 1.72 cm "T" Series ... 85% "KO" Series .. 95%
Product
Index

"SL" Series ... 85% "HS" Series .. 90%

58 15⁄8" Framing System


Closure Strips for 15⁄8" (41mm) Channel

P1184 Wt/100 Ft: 27 Lbs (40.2 kg/100 m) P1184 P Wt/100 Ft: 11 Lbs (16.5 kg/100 m)

Channel
Standard length: 10' (3m) Standard length: 10' (3m)

15⁄8"
Telestrut
System
Hardware
Nuts &
General
Fittings
.020" .085"
(0.5) (2.2)

Finish: Pregalvanized, plain. 1 5⁄8" Material: Paintable PVC. 1 5⁄8"


(41.3) Color: Green, Grey. (41.3)

Pipe/Conduit
Supports
P3184 Wt/100 Ft: 47 Lbs (69.9 kg/100 m) P3184 P Wt/100 Ft: 9.4 Lbs (14.0 kg/100 m)
Standard length: 10' (3m) Standard length: 10' (3m)

Electrical
Fittings
Concrete
Inserts
11⁄4" Framing
System
.040" .085"
(1.0) (2.2)
Finish: Green, pre-galvanized, plain. 1 5⁄8" Material : G.E. Noryl® Plastic. 1 5⁄8"
(41.3) Color: Green, Grey and White. (41.3)

Framing
System
P3184 F Wt/100 Ft: 90 Lbs (134 kg/100 m) P3712 P Wt/100 Ft: 5.4 Lbs (8.0 kg/100 m)
Standard length: 16' (4.9m) Standard length: 10' (3m)

13⁄16"
Fiberglass
System
Special
Metals
PrimeAngle
System

.040" .040"
(1.0)
(1.0)
Finish: Green, pre-galvanized, plain. 5 Material: Plastic.
1 ⁄8"
(41.3) Color: Black. 1 1⁄16"
3" Note: Use with P3170, P3270, and (27.0)
Product
Index

(76.2) P3370 series concrete insert.

15⁄8" Framing System 59


® End Caps and Frame Caps

P2859 Frame Caps P1180, P2280,P4280, P5280, P5580


Channel
15⁄8"
Telestrut
System

Part Use With Wt/100 pcs


Number Channel Lbs (kg)
Hardware
Nuts &

Part Use With Wt/100 pcs P1180 P1100 12


Number* Channel Lbs (kg) 5.4
P2280 P2000 11
P2859-10 P1000 12
5.0
5.4
P4280 P4000 5
General
Fittings

P2859-11 P1001 12
2.3
5.4
P5280 P5000 22
P2859-12 P3300 5
10.0
2.3
P5580 P5500 17
P2859-13 P5000 22
Pipe/Conduit

7.7
10.0
Supports

P2859-14 P5500 17 Material: .075" (1.9)


7.7

* Add color suffix:


Note: For P3000 and P3300
GR - Green WH - White GY - Grey
Electrical
Fittings

See Page 201


"A" series frame caps available

P1280 Wt/100 pcs: 11 Lbs (5.0 Kg.) P1280 A, P2280 A


Concrete
Inserts
11⁄4" Framing
System

Part Use With Wt/100 pcs


Number Channel Lbs (kg)
P1280A P1000 11
5.0
⁄16" Framing

Use with P1000 P2280A P2000 11


Material: .060" (1.5) 5.0
System

Material: .075" (1.9)


13

P2860 PLASTIC WHITE END CAPS


Fiberglass
System
Special
Metals
PrimeAngle
System

1" 1" 1" 1"


(25.4) (25.4) (25.4) (25.4)

P2860-10 P2860-33 P2860-50 P2860-55


Use with P1000, P1100, P2000 Use with P3300 channel. Use with P5000 & P1001 Use with P5500 channel.
Product
Index

channels & P9000 Telestrut. Wt/100 pcs 2.5 Lbs (1.1 kg) channels. Wt/100 pcs 4.7 Lbs (2.1 kg)
Wt/100 pcs 3.4 Lbs (1.5 kg) Wt/100 pcs 5 Lbs (2.3 kg)

60 15⁄8" Framing System


Lateral Bracing Reduction

Lateral Bracing Load Reduction Charts

Channel
15⁄8"
Lateral Bracing Factors
Span Single Channel
Ft. (m) In. (cm) P1000 P1100 P2000 P3000 P3300 P4000 P4100 P5000 P5500

Telestrut
System
2 24 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.98 0.99
0.61 61.0
3 36 0.94 0.89 0.88 0.96 1.00 0.94 0.98 0.85 0.89
0.91 91.4
4 48 0.88 0.78 0.75 0.91 1.00 0.88 0.94 0.70 0.77

Hardware
Nuts &
1.22 121.9
5 60 0.82 0.68 0.61 0.88 0.98 0.83 0.91 0.55 0.67
1.52 152.4
6 72 0.78 0.59 0.48 0.84 0.97 0.79 0.89 0.44 0.58
1.83 182.9

General
Fittings
7 84 0.75 0.52 0.41 0.82 0.96 0.75 0.86 0.38 0.51
2.13 213.4
8 96 0.71 0.47 0.35 0.79 0.94 0.72 0.84 0.33 0.46
2.44 243.8

Pipe/Conduit
9 108 0.69 0.43 0.32 0.77 0.93 0.69 0.82 0.30 0.42

Supports
2.74 274.3
10 120 0.66 0.40 0.29 0.75 0.92 0.66 0.80 0.28 0.40
3.05 304.8
12 144 0.61 0.36 0.25 0.70 0.89 0.60 0.76 0.24 0.36
3.66 365.8

Electrical
Fittings
14 168 0.55 0.32 0.23 0.66 0.86 0.55 0.73 0.22 0.32
4.27 426.7
16 192 0.51 0.30 0.21 0.62 0.84 0.50 0.69 0.21 0.30
4.88 487.7
18 216 0.47 0.28 0.19 0.58 0.81 0.47 0.65 0.19 0.28

Concrete
Inserts
5.49 548.6
20 240 0.44 0.26 0.18 0.54 0.78 0.43 0.61 0.18 0.26
6.10 609.6

Lateral Bracing Factors

11⁄4" Framing
Span Double Channel

System
Ft. (m) In. (cm) P1001 P1101 P2001 P3001 P3301 P4001 P4101 P5001 P5501
2 24 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
0.61 61.0
3 36 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
0.91 91.4

Framing
4 48 1.00 0.98 0.98 1.00 1.00 0.98 1.00 0.97 0.98

System
1.22 121.9
5 60 0.97 0.93 0.92 0.98 1.00 0.93 0.96 0.90 0.93

13⁄16"
1.52 152.4
6 72 0.93 0.87 0.85 0.95 0.97 0.88 0.92 0.83 0.87
1.83 182.9

Fiberglass
System
7 84 0.89 0.82 0.78 0.92 0.95 0.83 0.89 0.76 0.81
2.13 213.7
8 96 0.85 0.76 0.71 0.88 0.92 0.79 0.85 0.68 0.76
2.434 243.8
9 108 0.81 0.70 0.64 0.85 0.90 0.74 0.81 0.61 0.70
Special
Metals

2.74 274.3
10 120 0.78 0.65 0.57 0.82 0.87 0.69 0.78 0.54 0.64
3.05 304.8
12 144 0.70 0.54 0.45 0.76 0.82 0.60 0.71 0.43 0.53
PrimeAngle

3.66 365.8
System

14 168 0.63 0.45 0.38 0.70 0.78 0.51 0.64 0.35 0.45
4.28 426.7
16 192 0.56 0.39 0.32 0.64 0.73 0.44 0.57 0.30 0.39
4.88 487.7
18 216 0.49 0.34 0.28 0.58 0.68 0.39 0.50 0.27 0.34
Product

5.49 548.6
Index

20 240 0.44 0.31 0.25 0.52 0.63 0.35 0.45 0.24 0.30
6.10 609.6

15⁄8" Framing System 61


® Bearing Loads

Bearing Loads on Unistrut Channel


Channel
15⁄8"
Telestrut

LOAD LOAD LOAD


System

Safety Factor
— 21⁄2
Hardware
Nuts &

Bearing Length 15⁄8" (41 mm) Bearing Length 15⁄8" (41 mm) Bearing Length 31⁄4" (82 mm)
Maximum Allowable Loads Maximum Allowable Loads Maximum Allowable Loads
Channel Lbs (kg) Lbs (kg) Lbs (kg)
P1000 6,700 3,100 7,700
(3,000) (1,400) (9,400)
General
Fittings

P1100 3,500 1,700 4,000


(1,500) (700) (1,800)
P2000 2,500 1,200 3,000
(1,100) (500) (1,300)
Pipe/Conduit
Supports

P3000 6,700 3,200 7,700


(3,000) (1,400) (3,500)
P3300 6,800 3,200 7,800
(3,000) (1,400) (3,500)
P4000 2,600 1,200 3,000
Electrical

(900) (500) (1,300)


Fittings

P4100 3,500 1,800 4,100


(1,600) (800) (1,800)
P5000 6,500 3,000 7,500
(2,900) (1,300) (3,400)
Concrete
Inserts

P5500 6,600 3,100 7,600


(3,000) (1,400) (3,400)
11⁄4" Framing
System
⁄16" Framing
System
13
Fiberglass
System
Special
Metals
PrimeAngle
System
Product
Index

62 15⁄8" Framing System


®
TELESTRUT® SYSTEM
Telescoping Tube ................................................ 67
Connection Methods .......................................... 70
Specialized Fittings ............................................. 71

Post Bases ............................................................ 72


Cutting Chart ....................................................... 73

MATERIAL DESIGN BOLT TORQUE


Unistrut channels are accurately and carefully cold
formed to size from low-carbon strip steel. 1⁄4"-20 5⁄16"-18 3⁄8"-16 1⁄2"-13 5
BOLT SIZE ⁄8"-11 3⁄4"-10
Rec. Torque 6 11 19 50 100 125
STEEL: PLAIN Ft/Lbs (N•m) (8) (15) (26) (68) (136) (170)
12 Ga. (2.7 mm), 14 Ga.(1.9 mm) and 16 Ga. (1.5 mm) Max Torque 7 15 25 70 125 150
ASTM A1011 SS GR 33. Ft/Lbs (N•m) (9) (20) (34) (95) (170) (203)

STEEL: PRE-GALVANIZED
12 Ga. (2.7 mm), 14 Ga. (1.9 mm) and 16 Ga. (1.5mm) DESIGN LOAD
ASTM A653 GR 33. Load tables and charts are constructed to be in accor-
dance with the SPECIFICATION FOR THE DESIGN OF
COLD-FORMED STEEL STRUCTURAL MEMBERS 2001
FINISHES EDITION published by the AMERICAN IRON AND STEEL
Fittings are available in: Perma-Green II (GR), electro- INSTITUTE.
galvanized (EG), conforming to ASTM B633 Type III SC1;
Hot-dipped galvanized (HG), conforming to ASTM A123 or Type Safety Factor Safety Factor
A153 and plain (PL). of Load to Yield Strength to Ultimate Strength
Beam Loads 1.67 2.0
DIMENSIONS Column Load 1.80 2.2
Imperial dimensions are illustrated in inches. Metric
dimensions are shown in parenthesis or as noted. Unless
noted, all metric dimensions are in millimeters and rounded
to one decimal place.

63
® Telestrut Pictorial Index

Telestrut Telescoping Tubing


Channel
15⁄8"

15⁄8" x 15⁄8" 17⁄8" x 17⁄8"


Telestrut
System

12 Ga. 12 Ga.

P9000-Pg 67 P9200-Pg 67
Hardware
Nuts &

Special Fittings and Connection Hardware for Telestrut Telescoping Tubing


General
Fittings
Pipe/Conduit

P9324-Pg 71 P9011-Pg 72 P9012-Pg 72 P9013-Pg 72 P9014-Pg 72


Supports
Electrical
Fittings

P9207-Pg 71 P9209-Pg 70 P9010-Pg 70


Concrete

Standard 15⁄8" Metal Framing – Flat Plate Fittings


Inserts
11⁄4" Framing
System

P1065-Pg 90 P1924-Pg 90 P1066-Pg 91 P1925-Pg 91 P1067-Pg 91 P2079-Pg 91


⁄16" Framing
System
13
Fiberglass

P1941-Pg 91 P1036-Pg 92 P1380A-Pg 92 P1334-Pg 92 P1380-Pg 92 P1873-Pg 92


System
Special
Metals

P1031-Pg 92 P1028-Pg 93 P1356-Pg 93 P1358-Pg 93 P1726-Pg 93 P1953-Pg 93


PrimeAngle
System

Many of the standard metal framing components


are compatible with the Telestrut telescoping
tubing. Refer to the appropriate page in other
sections of the catalog for information on the
Product
Index

particular fittings shown here.


P1950-Pg 93 P2325-Pg 90 P2324-Pg 91

64 Telestrut
Telestrut Pictorial Index

Standard 15⁄8" Metal Framing – Ninety Degree Fittings

Channel
15⁄8"
Telestrut
System
P1026-Pg 94 P1068-Pg 94 P1750-Pg 95 P1281-Pg 94 P1538A-Pg 95 P1498-Pg 95

Hardware
Nuts &
General
Fittings
P1747-Pg 95 P1458-Pg 95 P1326-Pg 96 P1346-Pg 96 P1325-Pg 96 P1822-Pg 96

Pipe/Conduit
Supports
Electrical
Fittings
P1823-Pg 96 P1821-Pg 96 P1934-Pg 99 P1033-Pg 97 P1037-Pg 97 P1038-Pg 97

Concrete
Inserts
11⁄4" Framing
P1034-Pg 97 P1035-Pg 97 P1029-Pg 97 P1357-Pg 98 P1359-Pg 98 P1381-Pg 98

System
Framing
System
13⁄16"
P1290-Pg 98 P1291-Pg 98 P1579-Pg 99 P1727-Pg 99 P1728-Pg 99 P2235-Pg 99

Fiberglass
System
P1713-Pg 99 P1130-Pg 100 P1956-Pg 100 P1957-Pg 100
Special
Metals

Standard 15⁄8" Metal Framing – "Z" and "U" Shape Fittings


PrimeAngle
System
Product
Index

P1045-Pg 102 P1347-Pg 102 P1479-Pg 103 P1047-Pg 106 P1048-Pg 107 P2326-Pg 109

Telestrut 65
® Telestrut Pictorial Index

Standard 15⁄8" Metal Framing – Wing Shape Fittings


Channel
15⁄8"
Telestrut
System

P2343-Pg 110 P2223-Pg 110 P2224-Pg 110 P2225-Pg 110 P2227-Pg 110 P2228-Pg 110
Hardware
Nuts &
General
Fittings

P2229-Pg 111 P2345-Pg 111 P2346-Pg 111 P2347-Pg 111 P2344-Pg 111 P2226-Pg 111
Pipe/Conduit
Supports
Electrical
Fittings

P2230-Pg 112 P2245-Pg 112 P2348-Pg 112 P2341-Pg 109 P2472-Pg 109
Concrete
Inserts

Standard 15⁄8" Metal Framing – Misc. Fittings


11⁄4" Framing
System

P1843-Pg 138 P1354-Pg 138 P1201-Pg 138 P1204-Pg 139 P1944-Pg 139 P2655-Pg 139
⁄16" Framing
System
13

P2354L-Pg 138 P2354R-Pg 138 P2231-Pg 119 P2233-Pg 119 P1271S-Pg 128 P1796S-Pg 128
Fiberglass
System
Special
Metals

P2785-Pg 129 P2867-Pg 130 P2868-Pg 130 P1887-Pg 112 P2072A-Pg 113 P2072-Pg 113
PrimeAngle
System
Product

P2860-10-Pg 60
Index

66 Telestrut
P9000 & P9200 Telestrut Channels

P9000 Wt/100 Ft: 188 Lbs (279 kg/100 m)

Channel
Allowable Moment 5,140 In-Lbs (580 N•m)

15⁄8"
12 Gauge Nominal Thickness .105" (2.7mm)

1 5⁄8"

Telestrut
41.3

System
Hardware
1 5⁄8" 1 41.3 1

Nuts &
9
⁄16" (14.3) Dia. Holes
1 7⁄8" (47.6) on Center
1 7⁄8"
2 2 (47.6)

General
Fittings
Pipe/Conduit
Supports
P9200 Wt/100 Ft: 223 Lbs (331 kg/100 m)
Allowable Moment 7,480 In-Lbs (850 N•m)
12 Gauge Nominal Thickness .105" (2.7mm)
1 7⁄8" 47.6

Electrical
Fittings
1 7⁄8" 1 47.6 1

Concrete
Inserts
9
⁄16" (14.3) Dia. Holes
1 7⁄8" (47.6) on Center
2 2
1 7⁄8"
(47.6)

11⁄4" Framing
System
Telestrut's Telescoping Power
Telestrut can be combined with metal

Framing
framing channel

System
P9200

13⁄16"
Fiberglass
System
9⁄16" (14.3) Dia. Holes
1 7⁄8" (47.6) on Center
P9000
Special
Metals

P1000 Series P1100 Series


PrimeAngle
System
Product

P4001 Series P4101 Series


Index

Channel Finishes: PL, GR, PG; Standard Length: 20'

Telestrut 67
® P9000 & P9200 Telestrut Channels

BEAM LOADING – P9000 BEAM LOADING – P9200


Channel
15⁄8"

Max Defl. at Max Defl. at


Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360
Telestrut
System

In Lbs In Lbs Lbs Lbs In Lbs In Lbs Lbs Lbs


24 1,710 0.06 1,710 1,710 1,710 24 2,490 0.05 2,490 2,490 2,490
36 1,140 0.14 1,140 1,140 810 36 1,660 0.12 1,660 1,660 1,350
48 860 0.25 860 680 450 48 1,250 0.22 1,250 1,140 760
Hardware
Nuts &

60 690 0.40 580 440 290 60 1,000 0.34 980 730 490
72 570 0.57 400 300 200 72 830 0.49 680 510 340
84 490 0.77 300 220 150 84 710 0.67 500 370 250
96 430 1.01 230 170 110 96 620 0.87 380 290 190
General
Fittings

108 380 1.27 180 130 90 108 550 1.10 300 230 150
120 340 1.56 150 110 70 120 500 1.37 240 180 120
144 290 2.30 100 80 50 144 420 1.98 170 130 80
Pipe/Conduit

168 240 3.02 70 60 40 168 360 2.70 120 90 60


Supports

192 210 3.95 60 40 NR 192 310 3.47 100 70 50


216 190 5.09 40 NR NR 216 280 4.47 80 60 NR
240 170 6.24 40 NR NR 240 250 5.47 60 50 NR

COLUMN LOADING – P9000 COLUMN LOADING – P9200


Electrical
Fittings

Maximum Maximum
Unbraced Allowable Load Maximum Column Load Applied at C.G. Unbraced Allowable Load Maximum Column Load Applied at C.G.
Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
Concrete
Inserts

In Lbs Lbs Lbs Lbs Lbs In Lbs Lbs Lbs Lbs Lbs
24 3,640 8,730 8,570 8,330 8,040 24 4,620 11,120 10,980 10,740 10,460
36 3,540 8,360 8,040 7,530 6,950 36 4,530 10,770 10,460 9,950 9,370
48 3,400 7,880 7,340 6,530 5,660 48 4,390 10,300 9,760 8,940 8,030
11⁄4" Framing

60 3,210 7,290 6,530 5,440 4,360 60 4,220 9,720 8,940 7,800 6,590
System

72 2,990 6,640 5,660 4,360 3,160 72 4,000 9,050 8,030 6,590 5,180
84 2,730 5,940 4,790 3,340 2,320 84 3,750 8,320 7,080 5,410 3,890
96 2,430 5,220 3,940 2,560 1,780 96 3,460 7,560 6,110 4,290 2,980
108 2,110 4,520 3,160 2,020 1,400 108 3,140 6,770 5,180 3,390 2,360
⁄16" Framing

120 1,820 3,840 2,560 1,640 ** 120 2,790 5,990 4,290 2,750 1,910
System

144 1,390 2,690 1,780 ** ** 144 2,170 4,510 2,980 1,910 **


168 1,720 3,320 2,190 ** **
NR = Not Recommended. ** KL⁄r > 200
13

Notes: 1. Above loads include the weight of the member. This must be deducted to arrive at the net allowable load the beam will support.
2. Long span beams should be supported in such a manner as to prevent rotation and twist.
Fiberglass
System

3. Allowable uniformly distributed loads are listed for various simple spans, that is, a beam on two supports.
If load is concentrated at the center of the span, multiply load from the table by 0.5 and corresponding deflection by 0.8.
4. Refer to chart for lateral bracing reduction.

ELEMENTS OF SECTION - P9000/P9200 LATERAL BRACING REDUCTION


Special
Metals

Parameter P9000 P9200 ▲ P9000 P9200


2 2 100 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
Area of Section 0.387 In 0.489 In ▲ ▲
% OF ALLOWABLE
LOAD RETAINED

Axis 1-1
PrimeAngle

90
Moment of Inertia (I) 0.166 In4 0.279 In4
System

Section Modulus (S) 0.205 In3 0.297 In3 80


Radius of Gyration (r) 0.655 In 0.755 In
Axis 2-2 70
Moment of Inertia (I) 0.166 In4 0.279 In4
Product
Index

Section Modulus (S) 0.205 In3 0.297 In3 60


12 24 36 48 60 72 84 96 108 120
Radius of Gyration (r) 0.655 In 0.755 In
DISTANCE (In) BETWEEN LATERAL BRACES

68 Telestrut
P9000 & P9200 Telestrut Channels

BEAM LOADING – P9000 (METRIC) BEAM LOADING – P9200 (METRIC)

Channel
15⁄8"
Max Defl. at Max Defl. at
Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360

Telestrut
System
mm kg mm kg kg kg mm kg mm kg kg kg
600 789 2 789 789 789 600 1,148 1 1,148 1,148 1,148
750 630 2 630 630 544 750 921 2 921 921 912
1,000 476 4 476 458 304 1,000 689 4 689 689 513

Hardware
Nuts &
1,250 381 7 381 295 195 1,250 553 6 553 494 327
1,500 318 10 272 204 136 1,500 458 8 458 340 227
1,750 272 13 200 150 100 1,750 395 11 336 249 168
2,000 236 17 154 113 77 2,000 345 15 259 191 127

General
Fittings
2,500 191 27 100 73 50 2,500 277 23 163 122 82
3,000 159 39 68 50 32 3,000 231 34 113 86 59
3,500 136 53 50 36 27 3,500 195 45 82 64 41

Pipe/Conduit
4,000 118 68 36 27 18 4,000 172 60 64 50 32

Supports
4,500 104 86 32 23 14 4,500 154 76 50 36 27
5,000 95 108 23 18 NR 5,000 136 92 41 32 23
6,000 77 151 18 NR NR 6,000 113 132 27 23 NR

COLUMN LOADING – P9000 (METRIC) COLUMN LOADING – P9200 (METRIC)

Electrical
Fittings
Maximum Maximum
Unbraced Allowable Load Maximum Column Load Applied at C.G. Unbraced Allowable Load Maximum Column Load Applied at C.G.
Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2

Concrete
mm kg kg kg kg kg mm kg kg kg kg kg

Inserts
600 1,656 3,964 3,896 3,787 3,660 600 2,096 5,048 4,985 4,881 4,754
750 1,633 3,892 3,787 3,624 3,434 750 2,077 4,980 4,881 4,722 4,531
1,000 1,592 3,738 3,565 3,293 2,994 1,000 2,037 4,831 4,663 4,395 4,087

11⁄4" Framing
1,250 1,533 3,547 3,293 2,912 2,508 1,250 1,987 4,645 4,395 4,005 3,579

System
1,500 1,465 3,329 2,994 2,508 2,023 1,500 1,919 4,432 4,087 3,579 3,044
1,750 1,383 3,089 2,672 2,100 1,565 1,750 1,842 4,187 3,751 3,130 2,508
2,000 1,293 2,835 2,345 1,715 1,197 2,000 1,755 3,924 3,402 2,685 2,009
2,250 1,188 2,572 2,023 1,361 948 2,250 1,656 3,642 3,044 2,254 1,588

Framing
2,500 1,075 2,304 1,715 1,102 767 2,500 1,542 3,357 2,685 1,851 1,288

System
2,750 953 2,041 1,424 912 635 2,750 1,420 3,066 2,341 1,529 1,061

13⁄16"
NR = Not Recommended.
Notes: 1. Above loads include the weight of the member. This must be deducted to arrive at the net allowable load the beam will support.
2. Long span beams should be supported in such a manner as to prevent rotation and twist.

Fiberglass
System
3. Allowable uniformly distributed loads are listed for various simple spans, that is, a beam on two supports.
If load is concentrated at the center of the span, multiply load from the table by 0.5 and corresponding deflection by 0.8.
4. Refer to chart for lateral bracing reduction.

ELEMENTS OF SECTION - P9000/P9200 (METRIC) LATERAL BRACING REDUCTION


Special
Metals

Parameter P9000 P9200 ▲ P9000 P9200


100 ▲ ▲
Area of Section 2.50 cm2 3.16 cm2 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲
% OF ALLOWABLE

Axis 1-1
LOAD RETAINED

PrimeAngle

90
Moment of Inertia (I) 6.92 cm4 11.61 cm4
System

Section Modulus (S) 3.35 cm3 4.87 cm3


80
Radius of Gyration (r) 1.66 cm 1.92 cm
Axis 2-2 70
Moment of Inertia (I) 6.92 cm4 11.61 cm4
Product
Index

Section Modulus (S) 3.35 cm3 4.87 cm3 60


12 24 36 48 60 72 84 96 108 120
Radius of Gyration (r) 1.66 cm 1.92 cm
DISTANCE (In) BETWEEN LATERAL BRACES
Telestrut 69
® Telestrut Connection Methods

P9010 Multi-grip Rivet


Channel

Wt/100 pcs: 10 Lbs (4.5 kg)


15⁄8"
Telestrut
System

P9000 Inside
P9200
Hardware
Nuts &

Fitting Attached
to Tube Section 750 Lbs.
with Tube Section (340 Kg)
or Channel Inside Pullout
General
Fittings

Fitting Attached 1,200 Lbs.


to Tube Section (544 Kg)
or Channel
Pipe/Conduit
Supports

P9209 Gravity Pin


Wt/100 pcs: 47 Lbs (21.3 kg)
Electrical
Fittings
Concrete
Inserts
11⁄4" Framing
System
⁄16" Framing
System

Channel Nut Connection Through-Bolt Connection


Infinite Adjustment Incremental Adjustment
13

Nut &
Fiberglass
System

Bolt Bolt P1000 H3


Channel Nut
P9200
Special
Metals

P9200
Nut &
Bolt P9000
PrimeAngle
System

5
Any of the 1 ⁄8" (41 mm) channel can be connected to
the P9000 using standard channel nuts.
P9200
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel Fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)
9

70 Telestrut
Wing Shape Fittings

P9207 Cutting Alignment Gauge

Channel
15⁄8"
15⁄16"

(23.8) Branch

Telestrut
System
17⁄8" A
(47.6)

Hardware
Nuts &
Trunk
11⁄16"
(27.0) The cutting alignment guide ensures correct
cutting of branch members when used with
fittings to make connections. Refer to the

General
Fittings
table of page 73 for the appropriate value
for "A" for cutting.

Pipe/Conduit
Supports
P9324 Wt/100 pcs: 78 Lbs (35.0 kg)

Electrical
Fittings
327⁄32"
(97.6)

17⁄16"

Concrete
(36.5)

Inserts
327⁄32"
(97.6)

17⁄8"

11⁄4" Framing
(47.6)

System
Framing
System
13⁄16"
Fiberglass
System
Special
Metals
PrimeAngle
System
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel Fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)
9

Telestrut 71
® Post Bases

P9011 Wt/100 pcs: 332 Lbs (150.7 kg) P9012 Wt/100 pcs: 340 Lbs (154 kg)
Channel
15⁄8"

4 Holes 4 Holes
3 3
⁄4" (19.1) Dia. ⁄4" (19.1) Dia.
6" 6"
Telestrut
System

(152.4) (152.4)
3" 3"
(76.2) (76.2)
6" 6"
(152.4) (152.4)
3" 3"
(76.2)
Hardware

P9000 (76.2) P9200


Nuts &

3" 3" 3" 3"


(76.2) (76.2) Cut to (76.2) (76.2)
11⁄16"
Cut to
13⁄16"
6" (17.5) 6" (20.6)
General
Fittings

(152.4) (152.4)
Any 15⁄8"
P9200 Section
(Slides over) (Slides Inside)
Pipe/Conduit
Supports

53⁄8" 53⁄8"
(136.5) (136.5) P9200
1⁄4"
P9000 1⁄4"

(6.4) (6.4)
Electrical
Fittings
Concrete
Inserts

P9013 Wt/100 pcs: 318 Lbs (144.7 kg) P9014 Wt/100 pcs: 303 Lbs (137.5 kg)
11⁄4" Framing

4 Holes 4 Holes
3 3
⁄4" (19.1) Dia. ⁄4" (19.1) Dia.
System

6" 6"
(152.4) (152.4)
3" 3"
(76.2) (76.2)
6" 6"
(152.4) (152.4)
3" 3"
⁄16" Framing

(76.2) (76.2)
System

P1000 H3 P4101
3" 3" 3" 3"
(76.2) (76.2) Cut to (76.2) (76.2) Cut to
13

13⁄16" any
6" (20.6) 6" length
(152.4) (152.4)
Fiberglass
System

P9200 P9200
(Slides over) (Slides over)
Special
Metals

53⁄8" 53⁄8"
(136.5) P1000 H3 (136.5) P4101
1
1⁄4" ⁄4"
(6.4) (6.4)
PrimeAngle
System
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel Fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)
9

72 Telestrut
Cutting Chart

Cutting Chart

Channel
15⁄8"
15⁄8" (41.3) Branch 17⁄8" (47.6) Branch 15⁄8" (41.3) Branch 17⁄8" (47.6) Branch
Trunk Trunk Trunk Trunk Trunk Trunk Trunk Trunk
Fitting 15⁄8" (41.3) 17⁄8" (47.6) 15⁄8" (41.3) 17⁄8" (47.6) Fitting 15⁄8" (41.3) 17⁄8" (47.6) 15⁄8" (41.3) 17⁄8" (47.6)

Telestrut
System
P1026 A A A B P1726 A A A B
P1028 A A A B P1727 B NR NR NR
P1029 † † † † P1728 † † † †
P1031 A A A B P1747 † † † †

Hardware
P1033 B A A B P1750 † † † †

Nuts &
P1034 † † † † P1821 † † † †
P1035 A † † † P1822 † † † †
P1036 A A A B P1823 † † † †
P1037 † † † † P1843 D D D D

General
Fittings
P1038 † † † † P1873 † † † †
P1045 † † † † P1834 † NR NR NR
P1047 † † † † P1941 A A A B
P1048 † † † † P1950 A A A B

Pipe/Conduit
P1049 † † † † P1953 A A A B

Supports
P1050 † † † † P1956 † † † †
P1065 A A A B P1957 † † † †
P1066 A A A B P2223 A NR A NR
P1068 C NR NR NR P2224 A NR A NR
P1130 A A A C P2225 A NR A NR

Electrical
Fittings
P1131 A A A C P2226 A NR A NR
P1290 A NR NR NR P2227 A NR A NR
P1291 A NR NR NR P2228 A NR A NR
P1325 A NR NR NR P2229 A NR A NR
P1326 C NR NR NR P2230 A NR A NR

Concrete
Inserts
P1334 A A A B P2235 A NR NR NR
P1346 A A A B P2245 A NR A NR
P1347 C NR NR NR P2324 E NR NR F
P1354 D D D D P2325 E A A F

11⁄4" Framing
P1356 A A A B P2326 E NR NR F

System
P1357 A NR NR NR P2341 R-L A NR A NR
P1358 A A A B P2343 R-L A NR A NR
P1359 A NR NR NR P2344 R-L A NR A NR
P1380 A A A B P2345 A NR A NR
P1380 A A A A B P2346 A NR A NR

Framing
P1381 † † † † P2347 A NR A NR

System
P1382 † † † † P2348 A NR A NR
P1458 A NR NR NR P2472 R-L C NR A NR

13⁄16"
P1498 † † † † P2815 C NR NR NR
P1499 † † † † P2815 D C NR NR NR
P1538 A C A A C P9324 G G G G

Fiberglass
P1538 B C A A C P9325 A A A A

System
P1538 C C A A C P9484 A A A A
P1538 D C A A C
P1579 A NR NR NR Legend
P1713 † † † †
Special

Designator "A" Designator "A"


Metals

This table shows the value for "A" when using the specified fitting to connect A 11
⁄16" F 7
⁄16" *
the branch and trunk. Sizes "A" and "B" can be cut with the cutting alignment 26.9 11.1
gauge (P9207). Other sizes require special cutting. Those marked NR are not B 15
⁄16" G 15⁄32"
recommended.
PrimeAngle

23.8 26.6
System

13
Branch C ⁄16" NR Not
20.6 Recommended
A
D 11⁄4" † Special
31.8 Cutting Req'd
E 5
⁄8" * (See part dwg)
Product

15.9
Index

Trunk

Telestrut 73
® Telestrut

Preferred Three-Piece Assembly


Channel

P9000 (15⁄8") P9000 (15⁄8")


15⁄8"

In most applications, telescoping assemblies should


be made from three sections of Telestrut material.
Telestrut
System

The simplest construction utilizes a center section of


17⁄8" material (P9200) into which a 15⁄8" member
(P9000) is telescoped from each end. In this way, all P9200 (17⁄8")
intersecting verticals and horizontals are formed from
Hardware
Nuts &

15⁄8" members assuring maximum compatibility and


ease of assembly
General
Fittings

Alternate Three-Piece Assembly


Pipe/Conduit
Supports

P9200 (17⁄8") P9200 (17⁄8")


5
A similar technique is to use a center 1 ⁄8" center
member (P9000) which can be telescoped into 17⁄8"
members used at both ends. With this method, all
intersecting connections should be formed from
Electrical
Fittings

compatible 17⁄8" members.


P9000 (15⁄8")
or any other 15⁄8"
Metal Framing Channel
Concrete

(e.g., P1000 H3)


Inserts
11⁄4" Framing
System

Two-Piece Assembly
P9000 (15⁄8") P9000 (15⁄8")

Two-piece telescoping assemblies can be used, but


⁄16" Framing

special cutting of one or both telescoping members is


System

needed to achieve proper alignment of fittings at the


intersecting connections.
13

In addition, the right-angle members to which


P9200 (17⁄8")
telescoping pieces are attached must be cut according
Fiberglass
System

to the illustration at right to insure smooth movement


A + 1 ⁄8"
A

of telescoping members.
Special
Metals
PrimeAngle
System
Product
Index

74 Telestrut
®
NUTS & HARDWARE
Channel Nuts With Springs .............................. 78
Channel Nuts Without Springs ........................ 79
Top Retainer Nuts .............................................. 79
UNISTRU
T Stud Nuts ............................................................ 80

RU
T Hardware ............................................................ 81
UNIST

MATERIAL DESIGN BOLT TORQUE


Unistrut channel nuts are manufactured from mild steel
bars, and after machining operations are completed, they
are case hardened, assuring positive biting action into the 1⁄4"-20 5⁄16"-18 3⁄8"-16 1⁄2"-13 5
BOLT SIZE ⁄8"-11 3⁄4"-10
inturned edge of the Unistrut channel.
Rec. Torque 6 11 19 50 100 125
The standard channel nut conforms to ASTM A576 GR
Ft/Lbs (N•m) (8) (15) (26) (68) (136) (170)
1015 modified and A1011 SS GR 45. Max Torque 7 15 25 70 125 150
Ft/Lbs (N•m) (9) (20) (34) (95) (170) (203)
Screws conform to SAE J429 GR 2 (also meets and
exceeds ASTM A307). Proof Load 55KSI, Tensile Load
74 KSI DIMENSIONS
Imperial dimensions are illustrated in inches. Metric
FINISHES dimensions are shown in parenthesis or as noted.
Nuts, bolts and washers are electro-galvanized (EG), Unless noted, all metric dimensions are in millimeters
ASTM B633 Type III SC1 finish, unless otherwise noted. and rounded to one decimal place.

Many hardware items are also available in stainless steel. Many Unistrut nuts, bolts and hardware items are also
Consult factory for ordering information. available in standard metric dimensions. Consult factory
for ordering information.
THREADS
All threads on the nuts and bolts are Unified and
American coarse screw threads.

75
® Nuts & Hardware Pictorial Index

Channel Nuts With Spring


Channel
15⁄8"
Telestrut
System

P1006 - P1010 P1012S - P1024S P4006 - P4010 P4012S - P4023S


Pg 78 Pg 78 Pg 78 Pg 78
Hardware
Nuts &
General
Fittings

P5506 - P5510 P2378 - P2382


Pipe/Conduit

Pg 78 Pg 80
Supports

Channel Nuts Without Spring


Electrical
Fittings

P3016 P3006 - P3013 P1012 - P1024 P4012 - P4023


Pg 79 Pg 79 Pg 79 Pg 79
Concrete
Inserts
11⁄4" Framing
System

P1006T - P1010T, P4010T P4908


Pg 79 Pg 79

Hardware
⁄16" Framing
System
13

HHCS HFMS HRMS HSHS HCSS


Fiberglass

Pg 81 Pg 81 Pg 81 Pg 81 Pg 81
System
Special
Metals

HSQN HFLW HHXN HLKW P9010


Pg 82 Pg 82 Pg 82 Pg 82 Pg 82
PrimeAngle
System

P9209 HTHR HRCN P2485 HOCW


Product
Index

Pg 82 Pg 83 Pg 84 Pg 84 Pg 84

76 Nuts & Hardware


Channel Nut Loads

Maximum Allowable Pull-out And Slip Loads

Channel
15⁄8"
Allowable Resistance to

Telestrut
System
Channel Nut Pull-Out Strength Slip Torque
Size-Thread Gauge Channel Lbs (kg) Lbs (kg) Ft-Lbs (N•m)
3
⁄4" -10 12 2,500 1,700 *125
1,134 771 170

Hardware
5
⁄8" -11 12 2,500 1,500 *100

Nuts &
1,134 680 135
1
⁄2" -13 12 2,000 1,500 50
P1000 907 680 70
7
⁄16" -14 12 P3000 1,400 1,000 35

General
Fittings
P5000 635 454 50
3
⁄8" -16 12 P5500 1,000 800 19
454 363 25
5
⁄16" -18 12 800 500 11

Pipe/Conduit
363 227 15

Supports
1
⁄4" -20 12 600 300 6
272 136 8

Electrical
Fittings
1
⁄2" -13 12 1,500 1,500 50
680 680 70
3
⁄8" -16 12 1,000 800 19
P3300 454 363 25
5

Concrete
⁄16" -18 12 800 500 11

Inserts
363 227 15
1
⁄4" -20 12 600 300 6
272 136 8

11⁄4" Framing
System
1
⁄2" -13 14 1,400 1,000 50
635 454 70
3
⁄8" -16 14 P1100 1,000 750 19
454 340 25
&

Framing
5
⁄16" -18 14 P4100
800 400 11

System
363 181 15
1
⁄4" -20 14 600 300 6

13⁄16"
272 136 8

Fiberglass
System
1
⁄2" -13 16 1,000 1,000 50
454 454 70
3
⁄8" -16 16 1,000 750 19
P2000 454 340 25
Special

&
Metals
5
⁄16" -18 16 800 400 11
P4000 363 181 15
1
⁄4" -20 16 600 300 6
272 136 8
PrimeAngle
System

* May require 3⁄8" or 1⁄2" thick fitting.


Nut design loads include a minimum safety factor of 3.
Note: Refer to the Channel Nut Selection Chart on the following two pages for the part number.
Product
Index

Nuts & Hardware 77


® Channel Nuts With Spring

For Use With Channel


Channel

Channel nut Nut Size Wt/100 pcs P1000, P1100,


15⁄8"

Part number Thread Lbs (kg) P2000, P3000


P1006-0832 #8 -32 7 ■ – – –
3.2
P1006-1024 #10 -24 7 ■ – – –
Telestrut
System

3.2
1
P1006-1420 ⁄4" -20 7 ■ – – –
3.2
5
P1007 ⁄16" -18 6 ■ – – –
Hardware

2.7
Nuts &

3
P1008 ⁄8" -16 10 ■ – – –
4.5
7
P1009 ⁄16" -14 9 ■ – – –
4.1
General
Fittings

1
P1010 ⁄2" -13 12 ■ – – –
5.4
For Use With Channel
Channel nut Nut Size Wt/100 pcs P1000, P1100,
Part number Thread Lbs (kg) P2000, P3000
Pipe/Conduit
Supports

5
P1012S ⁄8" -11 21 ■ – – –
9.5
3
P1023S ⁄4" -10 21 ■ – – –
9.5
7
P1024S ⁄8" -9 21 ■ – – –
9.5
Electrical
Fittings

Channel nut Nut Size Wt/100 pcs For Use With Channel
Part number Thread Lbs (kg) P3300, P4000, P4100
P4006-0832 # 8 -32 7 – ■ – –
3.2
Concrete

P4006-1024 #10 -24 7 – ■ – –


Inserts

3.2
1
P4006-1420 ⁄4" -20 7 – ■ – –
3.2
5
P4007 ⁄16" -18 6 – ■ – –
11⁄4" Framing

2.7
System

3
P4008 ⁄8" -16 9 – ■ – –
4.1
7
P4009 ⁄16" -14 9 – ■ – –
4.1
1
P4010 ⁄2" -13 8 – ■ – –
⁄16" Framing

3.6
System

Channel nut Nut Size Wt/100 pcs For Use With Channel
Part number Thread Lbs (kg) P3300, P4000, P4100
5
P4012S ⁄8" -11 10 – ■ – –
13

4.5
3
P4023S ⁄4" -10 10 – ■ – –
4.5
Fiberglass
System

Channel nut Nut Size Wt/100 pcs For Use With


Part number Thread Lbs (kg) P5500

P5506-0832 #8 -32 7 – – – ■
3.2
Special
Metals

P5506-1024 #10 -24 7 – – – ■


3.2
1
P5506-1420 ⁄4" -20 7 – – – ■
3.2
PrimeAngle

5
P5507 ⁄16" -18 6 – – – ■
System

2.7
3
P5508 ⁄8" -16 10 – – – ■
4.5
7
P5509 ⁄16" -14 10 – – – ■
4.5
Product
Index

1
P5510 ⁄2" -13 12 – – – ■
5.4
■ Acceptable for use

78 Nuts & Hardware


Channel Nuts Without Spring

For Use With Channel

Channel
Channel nut Nut Size Wt/100 pcs P1000, P1100, P3300, P4000

15⁄8"
Part number Thread Lbs (kg) P2000, P3000 P4100 P5000 P5500
P3016-0632 #6 -32 2 ■ ■ ■ ■
0.9

Telestrut
P3016-0832 #8 -32 2 ■ ■ ■ ■

System
0.9
P3016-1024 #10 -24 4 ■ ■ ■ ■
1.8
1
P3016-1420 ⁄4" -20 4 ■ ■ ■ ■

Hardware
1.8

Nuts &
For Use With Channel
Channel nut Nut Size Wt/100 pcs P1000, P1100, P3300, P4000
Part number Thread Lbs (kg) P2000, P3000 P4100 P5000 P5500
P3006-0832 #8 -32 6 ■ ■ ■ ■

General
Fittings
2.7
P3006-1024 #10 -24 6 ■ ■ ■ ■
2.7
1
P3006-1420 ⁄4" -20 6 ■ ■ ■ ■

Pipe/Conduit
2.7

Supports
5
P3007 ⁄16" -18 6 ■ ■ ■ ■
2.7
3
P3008 ⁄8" -16 9 ■ ■ ■ ■
4.1
7
P3009 ⁄16" -14 9 ■ ■ ■ ■

Electrical
4.1

Fittings
1
P3010 ⁄2" -13 11 ■ – ■ ■
5.0
1
P3013 ⁄2" -13 8 – ■ – –
3.6

Concrete
For Use With Channel

Inserts
Channel nut Nut Size Wt/100 pcs P1000, P1100,
Part number Thread Lbs (kg) P2000, P3000 P5000 P5500
5
P1012 ⁄8" -11 20 ■ – ■ ■
9.1

11⁄4" Framing
3
P1023 ⁄4" -10 20 ■ – ■ ■

System
9.1
7
P1024 ⁄8" -9 20 ■ – ■ ■
9.1
Channel nut Nut Size Wt/100 pcs For Use With Channel
Part number Thread Lbs (kg) P3300, P4000, P4100

Framing
5
P4012 ⁄8" -11 11 – ■ – –

System
5.0
3
P4023 ⁄4" -10 11 – ■ – –

13⁄16"
5.0
For Use With Channel
Channel nut Nut Size Wt/100 pcs P1000, P1100, P3300, P4000
Part number Thread Lbs (kg) P2000, P3000 P4100 P5000 P5500

Fiberglass
System
1
P1006T1420 ⁄4" -20 7 ■ ■ ■ ■
UNISTRU 3.2
T
3
P1008T ⁄8" -16 10 ■ ■ ■ ■
RU
T 4.5
UNIST P1010T 1
⁄2" -13 12 ■ – ■ ■
Special
Metals

5.4
1
P4010T ⁄2" -13 8 – ■ – –
3.6
For Use With Channel
PrimeAngle

Channel nut Nut Size Wt/100 pcs P1000, P1100, P3300, P4000
System

Part number Thread Lbs (kg) P2000, P3000 P4100 P5000 P5500
3
P4908 ⁄8" -16 17.5 ■ ■ ■ ■
7.9
Double Conveyor Adjusting Nut
Product
Index

■ Acceptable for use

Nuts & Hardware 79


® Channel Nuts With Spring

Channel Stud Nut With Spring


Channel
15⁄8"

"A" For Use With Channel


Channel nut Nut Size Stud Wt/100 pcs P1000, P1100,
Part number Thread In (mm) Lbs (kg) P2000, P3000
Telestrut
System

P2378-1 1
⁄4" -20 1 8 ■
25.4 3.6
P2378-2 11⁄4 9 ■
31.8 4.1
11⁄2 ■
Hardware

P2378-3 9
Nuts &

38.1 4.1
A P2379-1 5
⁄16" -18 1 12 ■
25.4 5.4
P2379-2 11⁄4 12 ■
General

31.8 5.4
Fittings

P2379-3 11⁄2 13 ■
38.1 5.9
P2380-1 3
⁄8" -16 1 13 ■
25.4 5.9
Pipe/Conduit

11⁄4 ■
Supports

P2380-2 13
31.8 5.9
P2380-3 11⁄2 13 ■
38.1 5.9
P2380-4 13⁄4 15 ■
44.5 6.8
Electrical
Fittings

P2380-5 2 16 ■
All Stud Nut grooves are 50.8 7.3
serrated.
P2380-6 21⁄4 16 ■
Special stud lengths and 57.2 7.3
thread lengths can be
P2381-2 1
⁄2" -13 1 14 ■
Concrete

supplied upon request.


Inserts

25.4 6.4
P2381-3 11⁄4 15 ■
31.8 6.8
P2381-4 11⁄2 17 ■
11⁄4" Framing

38.1 7.7

System

P2381-5 13⁄4 18
44.5 8.2
P2381-6 2 19 ■
50.8 8.6
P2381-7 21⁄4 20 ■
57.2 9.1
⁄16" Framing

P2382-2 5
⁄8" -11 11⁄4 18 ■
System

31.8 8.2
■ Acceptable for use P2382-3 11⁄2 20 ■
38.1 9.1
13
Fiberglass
System
Special
Metals
PrimeAngle
System
Product
Index

80 Nuts & Hardware


Hardware

Hex Head Cap Screws Round Head Machine Screws

Channel
15⁄8"
Wt/100 pcs Wt/100 pcs
Part No. Size Lbs (kg) Part No. Size Lbs (kg)
1
HHCS025044EG ⁄4" x 7⁄16" 1.0 HRMS025050EG 1
⁄4" x 1⁄2" 1
0.5

Telestrut
0.5

System
1 3
HHCS025075EG ⁄4" x ⁄4" 1.3 HRMS025075EG 1
⁄4" x 3⁄4" 1.2
0.6 0.5
1
HHCS025150EG ⁄4" x 11⁄2" 2.6 HRMS025100EG 1
⁄4" x 1" 1.5
1.2 0.7

Hardware
5
HHCS031125EG ⁄16" x 11⁄4" 3.6

Nuts &
5
HRMS031100EG ⁄16" x 1" 2.6
1.6 1.2
3
HHCS037075EG ⁄8" x 3⁄4" 4.0 HRMS031125EG 5
⁄16" x 11⁄4" 3
1.8 1.4
3
HHCS037087EG ⁄8" x 7⁄8" 4.4 HRMS037100EG 3
⁄8" x 1" 4.1

General
Fittings
2.0 1.9
3
HHCS037100EG ⁄8" x 1" 4.5 HRMS037125EG 3
⁄8" x 11⁄4" 4.7
2.0 2.1
3
HHCS037125EG ⁄8" x 11⁄4" 5.3 HRMS037150EG 3
⁄8" x 11⁄2" 5.3

Pipe/Conduit
2.4 2.4

Supports
3
HHCS037150EG ⁄8" x 11⁄2" 6.0
2.7
3
HHCS037200EG ⁄8" x 2" 7.6
3.4
Hex Slotted Machine Screws
3
HHCS037225EG ⁄8" x 21⁄4" 8.4
3.8

Electrical
Fittings
HHCS037250EG 3
⁄8" x 21⁄2" 9.2 Wt/100 pcs
4.2 Part No. Size Lbs (kg)
1
HHCS050094EG 1
⁄2" x 15⁄16" 9.1 HSHS025050EG ⁄4" x 1⁄2" 1.4
4.1 0.6
1
⁄4" x 5⁄8"

Concrete
HHCS050119EG 1
⁄2" x 13⁄16" 10.2 HSHS025062EG 1.5

Inserts
4.6 0.7
1
HHCS050150EG 1
⁄2" x 11⁄2" 11.6 HSHS025075EG ⁄4" x 3⁄4" 1.7
5.3 0.8
5
HHCS050175EG 1
⁄2" x 13⁄4" 13.1 HSHS031100EG ⁄16" x 1" 2.6

11⁄4" Framing
5.9 1.2

System
5
HHCS050200EG 1
⁄2" x 2" 14.6 HSHS031125EG ⁄16" x 11⁄4" 3
6.6 1.4
5
HHCS050225EG 1
⁄2" x 21⁄4" 16 HSHS031150EG ⁄16" x 11⁄2" 3.4
7.3 1.5
3
HHCS050250EG 1
⁄2" x 21⁄2" 17.5 HSHS037125EG ⁄8" x 11⁄4" 5.3
2.4

Framing
7.9

System
Flat Head Machine Screws Cone Point Set Screws

13⁄16"
Wt/100 pcs
Wt/100 pcs Part No. Size Lbs (kg)

Fiberglass
Part No. Size Lbs (kg)

System
1
1
HCSS025100EG ⁄4" x 1" 2.8
HFMS025062EG ⁄4" x 5⁄8" 1.2 1.3
0.5 5
5
HCSS031150EG ⁄16" x 11⁄2" 3.9
HFMS031100EG ⁄16" x 1" 2.6 1.8
1.2 3
HCSS037150EG ⁄8" x 11⁄2" 4.5
Special
Metals
1
HFMS050100EG ⁄2" x 1" 9.3 2.0
4.2 3
HCSS037200EG ⁄8" x 2" 6.1
2.8
1
HCSS050150EG ⁄2" x 11⁄2" 8.5
PrimeAngle

3.9
System

1
HCSS050200EG ⁄2" x 2" 11.4
5.2
5
HCSS062150EG ⁄8" x 11⁄2" 14.5
6.6
5
HCSS062200EG ⁄8" x 2" 23.0
Product
Index

10.4

Nuts & Hardware 81


® Hardware

Square Nuts Hexagon Nuts


Channel
15⁄8"

Wt/100 pcs Wt/100 pcs


Part No. Size Lbs (kg) Part No. Size Lbs (kg)
1 1
HSQN025EG ⁄4" 0.9 HHXN025EG ⁄4" 0.6
Telestrut
System

0.4 0.3
5 5
HSQN031EG ⁄16" 1.6 HHXN031EG ⁄16" 1.2
0.7 0.5
3 3
HSQN037EG ⁄8" 2.7 HHXN037EG ⁄8" 1.6
1.2 0.7
Hardware
Nuts &

1 1
HSQN050EG ⁄2" 5.8 HHXN050EG ⁄2" 4.8
2.6 2.2
5 5
HSQN062EG ⁄8" 10.7 HHXN062EG ⁄8" 7.3
4.9 3.3
3 3
HSQN075EG ⁄4" 15.4 HHXN075EG ⁄4" 11.9
General
Fittings

6.9 5.4
7 7
HSQN087EG ⁄8" 24.9 HHXN087EG ⁄8" 19
11.3 8.6
HSQN100EG 1" 36.3 HHXN100EG 1" 28.3
Pipe/Conduit

16.5 12.8
Supports

Flat Washers Lock Washers


Wt/100 pcs Wt/100 pcs
Electrical
Fittings

Part No. Size Lbs (kg) Part No. Size Lbs (kg)
1 1
HFLW025EG ⁄4" 0.8 HLKW025EG ⁄4" 0.25
0.4 0.1
5 5
HFLW031EG ⁄16" 1 HLKW031EG ⁄16" 0.41
0.5 0.2
Concrete
Inserts

3 3
HFLW037EG ⁄8" 1.5 HLKW037EG ⁄8" 0.63
0.7 0.3
1 1
HFLW050EG ⁄2" 3.5 HLKW050EG ⁄2" 1.32
1.6 0.60
11⁄4" Framing

5 5
HFLW062EG ⁄8" 7.7 HLKW062EG ⁄8" 2.20
System

3.5 1.0
3 3
HFLW075EG ⁄4" 11 HLKW075EG ⁄4" 3.80
5.0 1.7
7 7
HFLW087EG ⁄8" 15.3 HLKW087EG ⁄8" 6.00
6.9 2.7
⁄16" Framing

HFLW100EG 1" 18.8 HLKW100EG 1" 8.80


8.5 4.0
System

P9010 Rivet P9209 Gravity Pin


13

Wt/100 pcs: 10.0 Lbs (4.5 kg) Wt/100 pcs: 10.0 Lbs (4.5 kg)

3 1
⁄4" ⁄4"
Fiberglass
System

(19.1) (6.4) 2 3⁄8"


(60.3)

1 7⁄8" 1
⁄2"
P9000, or (47.6) (12.7)
Special
Metals

17⁄32" P1000H3 2 1⁄8"


(13.5) (54.0)
PrimeAngle
System

P9200
For use with For use with
P9000, P9200 & P1000 H3 P9000, P9200 & P1000 H3.
Product
Index

82 Nuts & Hardware


Hardware

Steel Threaded Rod

Channel
15⁄8"
Wt/100 Ft.

Telestrut
Part No. Size Lbs (kg)

System
1
HTHR025 ⁄4" x 20 13
5.9
5
HTHR031 ⁄16" x 18 20
9.1

Hardware
Nuts &
3
HTHR037 ⁄8" x 16 30
13.6
7
HTHR044 ⁄16" x 14 30
13.6
1
HTHR050 ⁄2" x 13 53

General
Fittings
24.0
5
HTHR062 ⁄8" x 11 84
38.1
3
HTHR075 ⁄4" x 10 124

Pipe/Conduit
56.2

Supports
7
HTHR087 ⁄8" x 9 170
77.1
Low Carbon Steel HTHR100 1" x 8 223
101.2
Fy = 32,000 psi
Ft = 52,000 psi

Electrical
Fittings
Concrete
Inserts
Load Carrying Capacity Of Threaded Hot Rolled Steel
Conforming To ASTM A575 And A576

11⁄4" Framing
Threaded Rod Loads for Piping Applications * Threaded Rod Loads for Structural Applications *

System
Maximum Allowed
Safe Load Nominal Tension
Nominal Root Area at 650°F (343°C) Nominal Area Load
Diameter In2 (mm2) Lbs (kg) Diameter In2 (mm2) Lbs (kg)
3
⁄8 0.068 730 1
⁄4 0.049 840

Framing
43.9 331 31.6 381

System
1
⁄2 0.126 1,350 3
⁄8 0.110 1,890
81.3 612 71.0 857

13⁄16"
5
⁄8 0.202 2,160 7
⁄16 0.150 2,570
130.3 980 96.8 1,166
3
⁄4 0.302 3,230 1
⁄2 0.196 3,360

Fiberglass
194.8 1,465 126.5 1,524

System
7
⁄8 0.419 4,480 5
⁄8 0.307 5,260
270.3 2,032 198.2 2,386
1 0.552 5,900 3
⁄4 0.442 7,580
356.1 2,676 285.4 3,438
Special

7
Metals

⁄8 0.601 10,310
* Based on MSS SP-58
388.0 4,677
1 0.785 13,470
506.8 6,110
PrimeAngle

* Based on AISC, Steel Construction Manual,


System

ASD, 9th Edition


Per AISC, Allowed Tensile Stress = 0.33 * Fu
Product
Index

Nuts & Hardware 83


® Hardware

Steel Coupler Nuts Slot Adapter™


Channel
15⁄8"
Telestrut
System

Length Wt/100 pcs


Hardware

Part No. Size In (mm) Lbs (kg)


Nuts &

1 7
HRCN025 ⁄4" - 20 ⁄8" 1.9
22.2 0.9
5
HRCN031 ⁄16" - 18 13⁄4" 7.5
44.5 3.4
General
Fittings

3
HRCN037 ⁄8" - 16 13⁄4" 9.0
44.5 4.1
7
HRCN044 ⁄16" - 14 13⁄4" 10.4
44.5 4.7
Pipe/Conduit

1
HRCN050 ⁄2" - 13 13⁄4" 10.0
Supports

44.5 4.5
5
HRCN062 ⁄8" - 11 21⁄8" 18.0
54.0 8.2
HRCN075 3
⁄4" - 10 21⁄4" 28.0 Bolt Wt/100 pcs
57.2 12.7 Part No. Size Lbs (kg)
1
7
21⁄2" HOCW025 ⁄4" 1
Electrical

HRCN087 ⁄8" - 9 55.0


Fittings

63.5 24.9 6.4 0.5


5
HRCN100 1" - 8 23⁄4" 73.0 HOCW037 ⁄16" 1.5
69.9 33.1 9.5 0.7
Concrete
Inserts

P2485 P1000 Channel Cradle Clip


P1000T Wt/100 pcs: 3.0 Lbs (1.4 kg)
Cradle Lateral Brace
Channel
Clip Stiffener
P2485 P1000 Channel
Transverse Brace
11⁄4" Framing

Cradle Clip
L
System

P1000T
Threaded Rod

P3008 Nut L 1 1⁄4"


(31.8)
⁄16" Framing

3
⁄8" x 1" Hex Head
System

Cap Screw P1546 Cradle clip only, order


other items seperately.
13

Refer to seismic bracing systems catalog for more detailed information.


................ Rod Stiffener Clip Spacing (L) ............
Fiberglass

Max. Allowable Rod Stress Rod Stress Rod Stress Rod Stress
System

Root Radius of Rod Compression @100% @75% @50% @35%


Rod Size Area Gyration @100% 10,700 PSI 8,025 PSI 5,350 PSI 3,745 PSI
In In2 (mm2) In (mm) Lbs (kg) In (mm) In (mm) In (mm) In (mm)
3
⁄8 0.068 0.074 970 9 11 13 15
43.87 1.88 440 229 279 330 381
Special
Metals

1
⁄2 0.126 0.100 1,790 12 14 17 21
81.29 2.54 812 305 356 432 533
5
⁄8 0.202 0.127 2,870 15 18 22 26
130.3 3.23 1302 381 457 559 660
PrimeAngle

3
⁄4 0.302 0.155 4,290 18 22 26 32
System

194.8 3.94 1,946 457 559 660 813

Notes:
1. Minimum Tensile Stress is 50,000 psi.
2. Design Compression Stress Assumed to be the same as Tension Working Stress - 10,700 psi
Product
Index

3. Compression Will Only Occur During a Seismic Event.


4. Compression Requires the Use fo Rod Sriffeners
5. When KL/r = 200, Rod Stress is at 35%

84 Nuts & Hardware


®
GENERAL FITTINGS
Flat Plate Fittings ......................................... 90-94
Ninety Degree Fittings .............................. 94-100
Angular Fittings ....................................... 101-102
“Z” Shape Fittings .................................... 102-104
“U” Shape Fittings ................................... 104-109
Wing Shape Fittings ................................ 109-112
Post Bases ................................................. 113-114
Brackets ..................................................... 115-120
Brace Fittings .................................................... 121
Beam Clamps ............................................ 123-135
Trolleys ...................................................... 136-137
Special Application Fittings ................... 138-139
Seismic Retrofit Fittings .......................... 140-144

MATERIAL DESIGN BOLT TORQUE


Fittings, unless noted, are made from hot-rolled, pickled 1⁄4"-20 5⁄16"-18 3⁄8"-16 1⁄2"-13 5
and oiled steel plates, strip or coil, and conform to ASTM BOLT SIZE ⁄8"-11 3⁄4"-10
specifications A575, A576, A635, or A36. The fitting steel Rec. Torque 6 11 19 50 100 125
also meets the physical requirements of ASTM A1011 SS Ft/Lbs (N•m) (8) (15) (26) (68) (136) (170)
GR 33. The pickling of the steel produces a smooth Max Torque 7 15 25 70 125 150
surface free from scale. Ft/Lbs (N•m) (9) (20) (34) (95) (170) (203)
Many fittings are also available in stainless steel,
aluminum and fiberglass. Consult factory for ordering SET SCREW TORQUE
information.
1⁄4"-20 5⁄16"-18 3⁄8"-16 1⁄2"-13 5 3⁄4"-10
BOLT SIZE 8"-11⁄
FINISHES Set Screw 40 60 125 250 400 665
Fittings are available in: Perma-Green II (GR), electro- Torque
In/Lbs (N•m) (4) (7) (14) (28) (45) (75)
galvanized (EG), conforming to ASTM B633 Type III SC1;
Hot-dipped galvanized (HG), conforming to ASTM A123 Note: Caution should be taken not to overtighten the set screw
or A153 and plain (PL).
DIMENSIONS
APPLICATION Imperial dimensions are illustrated in inches. Metric
All parts drawings illustrate only one application of each dimensions are shown in parenthesis or as noted. Unless
fitting. In most cases many other applications are noted, all metric dimensions are in millimeters and
possible. The channels shown in the illustrations are rounded to one decimal place.
P1000, 15⁄8" square, except where noted otherwise.
All 9⁄16" diameter holes use 1⁄2" x 15⁄16" hex head cap screws DESIGN LOAD
and 1⁄2" nuts – P1010, P4010 or P5510 – depending on the Design load data, where shown, is based on the ultimate
channel used. Nuts and bolts are not included with the strength of the connection with a safety factor of 2.5,
fitting and must be ordered separately. unless otherwise noted.

85
® General Fittings Pictorial Index

Flat Plate Fittings


Channel
15⁄8"
Telestrut
System

P1062-Pg 90 P1959-Pg 90 P2862-Pg 90 P1065-Pg 90 P1924-Pg 90 P2325-Pg 90 P2324-Pg 91 P1066-Pg 91 P1925-Pg 91


Hardware
Nuts &
General
Fittings

P1067-Pg 91 P2079-Pg 91 P1941-Pg 91 P1036-Pg 92 P1380 A-Pg 92 P1334-Pg 92 P1380-Pg 92 P1873-Pg 92 P1031-Pg 92
Pipe/Conduit
Supports

P1028-Pg 93 P1356-Pg 93 P1358-Pg 93 P1726-Pg 93 P1953-Pg 93 P1950-Pg 93 P1962-Pg 94

Angle Fittings
Electrical
Fittings
Concrete
Inserts

P2626-Pg 94 P1026-Pg 94 P1723-Pg 94 P1068-Pg 94 P1281-Pg 94 P1315-Pg 95 P1458-Pg 95 P1538A-Pg 95 P1750-Pg 95


11⁄4" Framing
System

P1498-Pg 95 P1747-Pg 95 P1326-Pg 96 P1821-Pg 96 P1346-Pg 96 P1325-Pg 96 P1822-Pg 96 P1823-Pg 96 P1033-Pg 97


⁄16" Framing
System
13
Fiberglass
System

P1037-Pg 97 P1038- Pg 97 P1034-Pg 97 P1029-Pg 97 P1035-Pg 97 P1290-Pg 98 P1291-Pg 98 P1357-Pg 98 P1359-Pg 98


Special
Metals

P1381-Pg 98 P1382- Pg 98 P1934-Pg 99 P1713-Pg 99 P1579-Pg 99 P1727-Pg 99 P1728-Pg 99 P2235-Pg 99 P1956-Pg 100
PrimeAngle
System
Product
Index

P1957-Pg 100 P2484-Pg 100 P2484W-Pg 100 P1130-Pg 100 P1546-Pg 101 P2101-Pg 101 P1186-Pg 101 P2260-Pg 102

86 General Fittings
General Fittings Pictorial Index

"Z" Shape Fittings

Channel
15⁄8"
Telestrut
System
P1045-Pg 102 P1347-Pg 102 P1453-Pg 102 P1454-Pg 102 P1479A-Pg 103 P1730-Pg 103 P1734-Pg 103 P1736-Pg 103 P2360-Pg 103

Hardware
Nuts &
P5560-Pg 103 P3045-Pg 104 P3345-Pg 104 P4045-Pg 104 P5545-Pg 104 P2469-Pg 104

General
Fittings
"U" Shape Fittings

Pipe/Conduit
Supports
P2800-Pg 104 P1320-Pg 105 P1363A-Pg 105 P1376-Pg 105 P4376-Pg 105 P1376A-Pg 105 P4376A-Pg 105 P1377-Pg 106 P1047-Pg 106

Electrical
Fittings
Concrete
Inserts
P3047-Pg 106 P4047-Pg 106 P1455-Pg 106 P5547-Pg 107 P1383-Pg 107 P1732-Pg 107 P2237-Pg 107 P5543-Pg 107 P1048-Pg 107

11⁄4" Framing
System
P1043A-Pg 108 P1737-Pg 108 P2473-Pg 108 P4043-Pg 108 P1044-Pg 108 P1973-Pg 108 P2326-Pg 109 P2328-Pg 109 P2329-Pg 109

Framing
Wing Shape Fittings

System
13⁄16"
Fiberglass
System
P1046A-Pg 109 P2341-Pg 109 P2472-Pg 109 P2343-Pg 110 P2223-Pg 110 P2224-Pg 110 P2225-Pg 110 P2227-Pg 110 P2228-Pg 110

Special
Metals

P2229-Pg 111 P2345-Pg 111 P2346-Pg 111 P2347-Pg 111 P2344-Pg 111 P2226-Pg 111 P2230-Pg 112 P2245-Pg 112 P2348-Pg 112
PrimeAngle
System

Post Bases
Product
Index

P1887-Pg 112 P2453-Pg 112 P2941-Pg 113 P2072-Pg 113 P2072A-Pg 113 P2073-Pg 114 P2073A-Pg 114

General Fittings 87
® General Fittings Pictorial Index

Brackets and Brace Fittings


Channel
15⁄8"
Telestrut
System

P1769-Pg 115 P1771-Pg 115 P1773-Pg 115 P1775-Pg 115 P1777-Pg 116 P1075-Pg 116 P1593-Pg 116 P2491-Pg 117
Hardware
Nuts &

P2494-Pg 117 P2500-Pg 117 P2547-Pg 118 P2944-Pg118 P2542-Pg 118 P2231-Pg 119 P2233-Pg 119 P2513-Pg 119
General
Fittings

P2231A-Pg 120 P2233A-Pg 120 P2513A-Pg 120 P2452-Pg 121 P2458-Pg 121 P2459-Pg 122 P2815-Pg 122 P2815D-Pg 122

Beam Clamps
Pipe/Conduit
Supports

P2897-Pg 123 P2784-Pg 123 PFL2-Pg 123 P2675-Pg 124 P2898-Pg 125 P2899-Pg 125 P2676-Pg 124 P2682-Pg 126 P2677-Pg 126 P2674-Pg 126
Electrical
Fittings
Concrete
Inserts

P2679-Pg 126 P1648S-Pg 127 P2398S-Pg 127 P1654A-Pg 128 P1271S-Pg 128 P1796S-Pg 128 P2785-Pg 129 P2786-Pg 129 P2787-Pg 129 P2824-Pg 129
11⁄4" Framing
System

P2867-Pg 130 P2867A-Pg 130 P2867B-Pg 130 P2868-Pg 130 P2868A-Pg 131 P2868B-Pg 131 P2893-Pg 131 P2894-Pg 131 P2895-Pg 132 P2896-Pg 132
⁄16" Framing
System

P1386-Pg 132 P1379S-Pg 132 P1272S-Pg 133 P3087-Pg 133 P3088-Pg 133 PLLCO25-Pg134 PFLO37-Pg134 PLF3037-Pg135 PLF9037-Pg135

Trolley Assemblies
13
Fiberglass
System

P2749-Pg 136 P2750-Pg 136 P2751-Pg 136 P2949-Pg 137 P2950-Pg 137 P1834-Pg 137 P1834A-Pg 137

Special Applications Fittings


Special
Metals
PrimeAngle

P1843-Pg 138 P1354A-Pg 138 P1354-Pg 138 P1201-Pg 138 P2354-Pg 138 P1204-Pg 139 P1944-Pg 139 P2655-Pg 139 P2470-Pg 139 P2454-Pg 139
System

Seismic Retrofit Fittings


Product
Index

SPF 100-Pg 140 SPF 200-Pg 141 SPF 300-Pg 142 SPF 400-Pg 143 LS 410-Pg 144 LS500-Pg 144

88 General Fittings
Design Load Data
DESIGN LOAD DATA FOR TYPICAL UNISTRUT CHANNEL CONNECTIONS
90° Fittings (When used in position shown)

Channel
15⁄8"
Channel Thickness Channel Thickness
Load – P1026 12 ga. 14 ga. 16 ga. Load – P2484 12 ga. 14 ga. 16 ga.
Lbs 1,500 1,000 750 LOAD Lbs 3,000 2,000 1,500

Telestrut
System
LOAD
kg 680.4 453.6 340.2 kg 1,360.8 907.2 680.4

Hardware
Nuts &
Channel Thickness

General
Fittings
Channel Thickness
Load – P1026 12 ga. 14 ga. 16 ga.
Load – P1068 12 ga. 14 ga. 16 ga.
Lbs 1,000 650 500
LOAD LOAD Lbs 500 500 500
kg 453.6 294.8 226.8
kg 226.8 226.8 226.8

Pipe/Conduit
Supports
Electrical
Fittings
Channel Thickness
Channel Thickness
Load – P1325, P2235 12 ga. 14 ga. 16 ga.
Load – P1326 12 ga. 14 ga. 16 ga.
LOAD Lbs 2,000 2,000 1,500 LOAD Lbs 500 500 500

Concrete
Inserts
kg 907.2 907.2 680.4
kg 226.8 226.8 226.8

11⁄4" Framing
System
Channel Thickness
Load – P1458, P1579 12 ga. 14 ga. 16 ga. Channel Thickness
Load – P1346 12 ga. 14 ga. 16 ga.

Framing
Lbs 1,500 1,000 1,000

System
LOAD kg 680.4 453.6 453.6 Lbs 1,200 1,200 1,000
kg 544.3 544.3 453.6

13⁄16"
Fiberglass
System
LOAD
Channel Thickness
Load – P1346 12 ga. 14 ga. 16 ga.
Special
Metals

Channel Thickness
LOAD Load – P1065 12 ga. 14 ga. 16 ga.
Lbs 2,000 1,500 900
LOAD Lbs 1,000 800 600
kg 907.2 680.4 408.2
PrimeAngle

kg 453.6 362.9 272.2


System

Note:
Product
Index

(1) Both ends of beams supported.


(2) Load data is based on P1010 nut and 1⁄2" bolt.
(3) Safety factor = 21⁄2 based on ultimate strength of connection.
General Fittings 89
® Flat Plate Fittings

P1062, P1063, P1064, P1964, P2471, P2490 P1959, P1960, P1961


Channel
15⁄8"

Part Bolt Hole Wt/100 pcs Part U.S. Std. Wt/100 pcs
Number Size Size Lbs (kg) Number Thd Size Lbs (kg)
Telestrut
System

1 5⁄8" 3
1 1⁄2" 1 3⁄8"
P1062 5
⁄16" 11
⁄32" 18 P1959 ⁄8"-16 21 (38.1) (34.9)
(41.3)
8.2 9.5
1
P1063 3
⁄8" 7
⁄16" 18 P1960 ⁄2"-13 20
8.2 9.1
Hardware

5
P1064 1
⁄2" 9
⁄16" 17 P1961 ⁄8"-11 19
Nuts &

Tapped Hole
7.7 8.6
5 11
P1964 ⁄8" ⁄16" 16
MATERIAL: 3⁄8" (9.5 mm) thick
7.3
3 13
P2471 ⁄4" ⁄16" 15
General
Fittings

6.8
7 15
P2490 ⁄8" ⁄16" 14
6.4
Pipe/Conduit
Supports

P2862, 2863, 2864 P1065 Wt/100 pcs: 38 Lbs (17.2 kg)


Electrical
Fittings

Part Bolt Hole Wt/100 pcs


Number Size Size Lbs (kg) 1 5⁄8"
5 11 (41.3) 31⁄2"
P2862 ⁄16" ⁄32" 18 (88.9)
8.2
3 7
P2863 ⁄8" ⁄16" 18
Concrete
Inserts

8.2
1 9
P2864 ⁄2" ⁄16" 17
7.7
11⁄4" Framing
System
⁄16" Framing
System

P1924 Wt/100 pcs: 35 Lbs (15.9 kg) P2325 Wt/100 pcs: 55 Lbs (24.9 kg)
13

1 5⁄8"
Fiberglass
System

(41.3)
3 1⁄4" 5 1 ⁄ 4"
(82.6) (133.4)
Special
Metals

3 5⁄8"
(92.1)
PrimeAngle
System
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)
9

90 General Fittings
Flat Plate Fittings

P2324 Wt/100 pcs: 75 Lbs (34.0 kg) P1066 Wt/100 pcs: 56 Lbs (25.4 kg)

Channel
15⁄8"
5 3⁄8"
(136.5)

Telestrut
System
7 1⁄8"
(181.0)

Hardware
Nuts &
3 5⁄8"
(92.1)

General
Fittings
Pipe/Conduit
Supports
P1925 Wt/100 pcs: 50 Lbs (22.7 kg) P1067 Wt/100 pcs: 78 Lbs (35.4 kg)

4 7⁄8"

Electrical
(123.8)

Fittings
7 1⁄4"
(184.2)

Concrete
Inserts
11⁄4" Framing
1 5⁄8"

System
(41.3)
5
1 ⁄ 8"
(41.3)

Framing
System
P2079 Wt/100 pcs: 73 Lbs (33.1 kg) P1941 Wt/100 pcs: 94 Lbs (42.6 kg)

13⁄16"
3 1⁄2" 3 1⁄4" 9 1⁄8"

Fiberglass
(88.9) 1 5⁄8" (231.8)

System
(82.6)
(41.3)

Special
Metals
PrimeAngle
System
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: 9⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)

General Fittings 91
® Flat Plate Fittings

P1036 Wt/100 pcs: 58 Lbs (26.3 kg) P1380 A Wt/100 pcs: 80 Lbs (36.3 kg)
Channel
15⁄8"

3 1 ⁄2 "
(88.9) 5 3⁄8"
Telestrut
System

(136.5)

3 1⁄2"
(88.9) 3 1⁄2"
Hardware

(88.9)
Nuts &
General
Fittings
Pipe/Conduit
Supports

P1334 Wt/100 pcs: 70 Lbs (31.8 kg) P1380 Wt/100 pcs: 105 Lbs (47.6 kg)
Electrical
Fittings

3 1⁄2" 5 3⁄8"
(88.9) (136.5)
Concrete

3 1⁄2" 3 1⁄2"
Inserts

(88.9) (88.9)
11⁄4" Framing
System
⁄16" Framing
System

P1873 Wt/100 pcs: 150 Lbs (68.0 kg) P1031 Wt/100 pcs: 80 Lbs (36.3 kg)
13

5 3⁄8"
(136.5) 5 3⁄8"
Fiberglass

(136.5)
System

3 1⁄2"
(88.9)
5 3⁄8"
(136.5)
Special
Metals
PrimeAngle
System
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)
9

92 General Fittings
Flat Plate Fittings

P1028 Wt/100 pcs: 105 Lbs (47.6 kg) P1356 Wt/100 pcs: 70 Lbs (31.8 kg)

Channel
15⁄8"
5 3⁄8"
(136.5)

Telestrut
System
3 1⁄2"
3
5 ⁄8" (88.9)
(136.5)

Hardware
Nuts &
General
Fittings
3 1⁄2"
(88.9)

Pipe/Conduit
Supports
P1358 Wt/100 pcs: 105 Lbs (47.6 kg) P1726 Wt/100 pcs: 148 Lbs (67.1 kg)

Electrical
Fittings
5 3⁄8"
(136.5)
5 3⁄8"
(136.5)

Concrete
Inserts
11⁄4" Framing
System
3 1⁄2" 5 3 ⁄8"
(88.9) (136.5)

Framing
System
P1953 Wt/100 pcs: 176 Lbs (79.8 kg) P1950 Wt/100 pcs: 240 Lbs (108.9 kg)

13⁄16"
9 1⁄8"
9 1⁄8" (231.8)

Fiberglass
(231.8)

System
3 1⁄2"
(88.9) Special
Metals
PrimeAngle
System

5 3⁄8"
(136.5)
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: 9⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)

General Fittings 93
® Flat Plate & Ninety Degree Angle Fittings

P1962 Wt/100 pcs: 112 Lbs (50.8 kg) P2626 Wt/100 pcs: 40 Lbs (18.1 kg)
Channel
15⁄8"

41⁄2"
Telestrut
System

(114.3)
27⁄8"
(73.0)
2 1⁄8"
Hardware
Nuts &

(54.0)

2 1⁄ 8"
15⁄8" (54.0)
(41.3)
General
Fittings
Pipe/Conduit
Supports

P1026 Wt/100 pcs: 38 Lbs (17.2 kg) P1723 Wt/100 pcs: 34 Lbs (15.4 kg)

1 5⁄8"
Electrical
Fittings

(41.3)

2" Tapped
(50.8) 5
⁄16" - 18 Thd.
Concrete
Inserts

1 7⁄8"
(47.6)
1 7⁄8"
(47.6)
11⁄4" Framing
System

1 5⁄8"
(41.3)
⁄16" Framing
System

P1068 Wt/100 pcs: 38 Lbs (17.2 kg) P1281, P1282, P1283


13

A
Fiberglass
System

1 5⁄8" 1 7⁄8"
(41.3) (47.6)

2 1⁄4"
Special
Metals

(57.2)
Part “A” Wt/100 pcs
Number In (mm) Lbs (kg)
P1281 3 49
PrimeAngle

76.2 22.2
System

P1282 31/2 54
88.9 24.5
P1283 4 61
101.6 27.7
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)
9

94 General Fittings
Ninety Degree Angle Fittings

P1315 Wt/100 pcs: 45 Lbs (20.4 kg) P1458 Wt/100 pcs: 58 Lbs (26.3 kg)

Channel
15⁄8"
Telestrut
3
⁄4"

System
(19.1) 3 1⁄2"
(88.9)

2 1⁄4"
(57.2)

Hardware
Nuts &
1
⁄2"- 13 Stud

General
1 7⁄8"

Fittings
1 7⁄8"
(47.6) (47.6)

Pipe/Conduit
Supports
P1538A thru P1538D P1750 Wt/100 pcs: 38 Lbs (17.2 kg)

Part “A” Wt/100 pcs


Number In (mm) Lbs (kg)

Electrical
Fittings
P1538A 37⁄8 61 1 5 ⁄8"
98.4 27.7 (41.3) 2 5⁄8 "
(66.7)
P1538B 57⁄8 84
149.2 38.1
1 1 ⁄2 "
P1538C 77⁄8 107

Concrete
(38.1)

Inserts
200.0 48.5
P1538D 97⁄8 130
250.8 59.0 A

11⁄4" Framing
1 5⁄16"

System
(33.3)
7⁄8"
1
(47.6)

Framing
System
P1498, P1499 P1747 Wt/100 pcs: 66 Lbs (29.9 kg)

13⁄16"
Part “A” “B” Wt/100 pcs
Number In (mm) In (mm) Lbs (kg)
P1498 47⁄8 21⁄2 65

Fiberglass
123.8 63.5 29.5 2 5⁄8"

System
(66.7)
P1499 67⁄8 41⁄2 85 3 7⁄8"
174.6 114.3 38.6 (98.4)
1 1⁄2"
(38.1)

A
Special
Metals

2 1⁄ 2 "
(63.5) 1 5⁄16"
B
PrimeAngle

(33.3)
System

1 7 ⁄ 8"
(47.6)
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: 9⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)

General Fittings 95
® Ninety Degree Angle Fittings

P1326 Wt/100 pcs: 58 Lbs (26.3 kg) P1821 Wt/100 pcs: 71 Lbs (32.2 kg)
Channel
15⁄8"

1 5⁄8" 2"
(41.3)
Telestrut

(50.8)
System

4 1⁄8"
(104.8)
Hardware

1 7⁄16"
Nuts &

(36.5)

1 5⁄8"
General
Fittings

(41.3)
4 7⁄8"
(123.8)
Pipe/Conduit
Supports

P1346 Wt/100 pcs: 58 Lbs (26.3 kg) P1325 Wt/100 pcs: 78 Lbs (35.4 kg)

3 1⁄2"
Electrical
Fittings

7
1 ⁄8 " (88.9)
(47.6)

4 1⁄8"
(104.8)
Concrete
Inserts

3 7⁄8" 1 7⁄16"
(98.4) (36.5)
11⁄4" Framing
System
⁄16" Framing
System

P1822 Wt/100 pcs: 55 Lbs (24.9 kg) P1823 Wt/100 pcs: 55 Lbs (24.9 kg)
13
Fiberglass

3 1⁄4"
System

1 7⁄ 8" 1
3 ⁄ 4" (82.6) 1 5⁄8" 1 7⁄8"
(47.6) 5 (41.3) (47.6)
1 ⁄8" (82.6)
(41.3) 2"
(50.8)
2"
(50.8)
Special
Metals
PrimeAngle
System
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)
9

96 General Fittings
Ninety Degree Angle Fittings

P1033 Wt/100 pcs: 80 Lbs (36.3 kg) P1037 Wt/100 pcs: 58 Lbs (26.3 kg)

Channel
15⁄8"
2"
(50.8)

Telestrut
System
5 3⁄8"

Hardware
Nuts &
(136.5)

General
Fittings
2"
3 1⁄2" (50.8)
(88.9)

Pipe/Conduit
Supports
P1038 Wt/100 pcs: 58 Lbs (26.3 kg) P1034 Wt/100 pcs: 80 Lbs (36.3 kg)

Electrical
Fittings
3 1⁄2"
(88.9)

Concrete
Inserts
11⁄4" Framing
System
2" 2"
(50.8) 3 1⁄2" 3 1⁄2" (50.8)
(88.9) (88.9)

Framing
System
P1029 Wt/100 pcs: 105 Lbs (47.6 kg) P1035 Wt/100 pcs: 80 Lbs (36.3 kg)

13⁄16"
2"
(50.8)

Fiberglass
3 1⁄2"

System
3 1⁄2" (88.9)
(88.9)
Special
Metals
PrimeAngle

5 3⁄8" 2"
System

(136.5) (50.8) 3 1⁄2"


(88.9)
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: 9⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)

General Fittings 97
® Ninety Degree Angle Fittings

P1290 Wt/100 pcs: 101 Lbs (45.8 kg) P1291 Wt/100 pcs: 101 Lbs (45.8 kg)
Channel
15⁄8"

1 7⁄8"
1 7⁄8" (47.6)
(47.6)
Telestrut
System

3 7⁄8" 3 7 ⁄8 "
(98.4) (98.4)
Hardware
Nuts &

3 1⁄2"
(88.9)
3 1⁄2"
General
Fittings

(88.9)
Pipe/Conduit
Supports

P1357 Wt/100 pcs: 70 Lbs (31.8 kg) P1359 Wt/100 pcs: 105 Lbs (47.6 kg)
Electrical

1 5 ⁄8 "
Fittings

1 5⁄8" (41.3)
(41.3) 3 1 ⁄2 "
1
3 ⁄2" (88.9)
(88.9)
2 1⁄4"
Concrete
Inserts

(57.2) 4 1⁄8"
(104.8)
11⁄4" Framing
System
⁄16" Framing
System

P1381 Wt/100 pcs: 105 Lbs (47.6 kg) P1382 Wt/100 pcs: 105 Lbs (47.6 kg)
13

4 1⁄8" 4 1⁄8" 1 5⁄8"


1 5⁄8" (104.8) (104.8) (41.3)
(41.3)
Fiberglass

1 7⁄16"
System

1 7⁄16" (36.5)
(36.5)
Special
Metals

3 1⁄2" 3 1⁄2"
(88.9) (88.9)
PrimeAngle
System
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)
9

98 General Fittings
Ninety Degree Angle Fittings

P1934 Wt/100 pcs: 75 Lbs (34.0 kg) P1713 Wt/100 pcs: 97 Lbs (44.0 kg)

Channel
15⁄8"
3 1⁄4" 1 5⁄8"
(82.6) (41.3)

Telestrut
System
2 1⁄4"
(57.2)
3 1⁄2"

Hardware
(88.9)

Nuts &
1
⁄2"
2 1⁄4" (12.7)
(57.2) 1
⁄2"
(12.7) 2 1⁄2"
(63.5)

General
Fittings
1 5⁄8"
(41.3) 3 1⁄2"
(88.9)

Pipe/Conduit
Supports
P1579 Wt/100 pcs: 103 Lbs (46.7 kg) P1727 Wt/100 pcs: 154 Lbs (69.9 kg)

1 7⁄8" 3 7⁄8"
(47.6) (98.4)

Electrical
Fittings
1 3⁄16"
3 1⁄2" (30.2)
(88.9) 3 1⁄2"
(88.9)

Concrete
Inserts
2 1⁄4"
(57.2)

5 3⁄8"

11⁄4" Framing
(136.5)

System
Framing
System
P1728 Wt/100 pcs: 154 Lbs (69.9 kg) P2235 Wt/100 pcs: 135 Lbs (61.2 kg)

13⁄16"
1 5 ⁄ 8"
3 1⁄2" 3 1⁄2"

Fiberglass
(41.3)
(88.9)

System
5 3⁄8" (88.9)
(136.5)
4 1⁄ 8"
(104.8) 4 1⁄8"
1 7⁄16" (104.8)
Special

(36.5)
Metals
PrimeAngle
System
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: 9⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)

General Fittings 99
® Ninety Degree Angle Fittings

P1956 Wt/100 pcs: 230 Lbs (104.3 kg) P1957 Wt/100 pcs: 230 Lbs (104.3 kg)
Channel
15⁄8"

3 1⁄2" 5 3⁄8"
Telestrut

3 1⁄2"
System

(88.9) 5 3⁄8" (136.5)


(136.5) (88.9)
13
13 ⁄16"
⁄16" (20.6)
(20.6)
4 1⁄8"
Hardware
Nuts &

(104.8) 1 7⁄16"
7
1 ⁄16" (36.5)
(36.5)
4 1⁄8"
(104.8) Continuous
Continuous
Weld
General
Fittings

Weld
Pipe/Conduit
Supports

P2484 Wt/100 pcs: 134 Lbs (60.8 kg) P2484W Wt/100 pcs: 134 Lbs (60.8 kg)

4" 4"
Electrical

(101.6) (101.6)
Fittings

13
13
⁄16" ⁄16"
1 9⁄16" (20.6) (20.6) 1 9⁄16"
(39.7) (39.7) 4"
4"
(101.6) (101.6)
Concrete
Inserts

7
7
⁄8" ⁄8"
(22.2) (22.2)

Continuous
11⁄4" Framing

Weld
System
⁄16" Framing
System

P1130, P1131
13
Fiberglass
System

Part “A” “B” Wt/100 pcs


Number In (mm) In (mm) Lbs (kg)
P1130 65⁄8 4 190
1 168.3 101.6 86.2
Special

1 ⁄2 "
Metals

3 3⁄ 4 "
(38.1) P1131 85⁄8 6 242
(95.3)
219.1 152.4 109.8
B
A
1 1⁄ 2"
PrimeAngle

1 7 ⁄ 8"
System

(47.6) (38.1)
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)
9

100 General Fittings


Angular Fittings

P1546, P2094 thru P2100 Wt/100 pcs: 58 Lbs (26.3 kg)

Channel
15⁄8"
Part “A” “B” “C”
Number Degree (rad) In (mm) In (mm)
1 1⁄16" P2094 821⁄2° 39⁄16 111⁄16
(27.0) 1.44 90.5 42.9

Telestrut
System
P2095 75° 39⁄16 111⁄16
1.31 90.5 42.9
P2096 671⁄2° 31⁄2 13⁄4
1.18 88.9 44.5

Hardware
P2097 60° 33⁄8 17⁄8

Nuts &
1 1⁄16" 1.05 85.7 47.6
(27.0) A
B P2098 521⁄2° 31⁄4 21⁄16
0.92 82.6 52.4
P1546 45° 3 25⁄16

General
Fittings
0.79 76.2 58.7
C
P2099 371⁄2° 31⁄2 113⁄16
0.65 88.9 46.0
P2100 371⁄2° 211⁄16 25⁄8
0.65 68.3 66.7

Pipe/Conduit
Supports
P2101 thru P2104 Wt/100 pcs: 58 Lbs (26.3 kg)

Electrical
Fittings
Part “A” “B”
Number Degree (rad) In (mm)
P2101 30° 31⁄4
1
1 ⁄16" 0.52 82.6

Concrete
Inserts
(27.0) P2102 221⁄2° 35⁄16
A 0.39 84.1
P2103 15° 35⁄16
B 0.26 84.1
P2104 71⁄2° 35⁄16

11⁄4" Framing
0.13 84.1

System
1 1⁄16" 2 1⁄16"
(27.0) (52.4)

Framing
System
P1186, P2105 thru P2110 Wt/100 pcs: 58 Lbs (26.3 kg)

13⁄16"
Part “A” “B”
Number Degree (rad) In (mm)
P2105 821⁄2° 33⁄16

Fiberglass
1.44 81.0

System
B P2106 75° 33⁄16
1.31 81.0
P2107 671⁄2° 31⁄8
A
1.18 79.4
31⁄8
Special

P2108 60°
Metals

1.05 79.4
P2109 521⁄2° 31⁄16
2 1⁄2" 0.92 77.8
(63.5) P1186 45° 31⁄8
PrimeAngle

0.79 79.4
System

P2110 371⁄2° 3
0.65 76.2
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: 9⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)

General Fittings 101


® Angular & “Z” Shape Fittings

P2260 thru P2270 Wt/100 pcs: 78 Lbs (35.4 kg)


Channel
15⁄8"

Part “A” “B” Part “A” “B”


Number Degree (rad) In (mm) Number Degree (rad) In (mm)
Telestrut

P2270 821⁄2° 3 5⁄ 8 P2264 371⁄2° 311⁄16


System

1.44 91.1 0.65 93.7


P2269 75° 3 5⁄ 8 P2263 30° 311⁄16
A 1.31 91.1 0.52 93.7
P2268 671⁄2° 3 5⁄ 8 P2262 221⁄2° 33⁄4
Hardware

1.18 91.1 0.39 95.3


Nuts &

B
P2267 60° 311⁄16 P2261 15° 33⁄4
1.05 93.7 0.26 95.3
P2266 521⁄2° 311⁄16 P2260 71⁄2° 33⁄4
3 1⁄ 2" 0.92 93.7 0.13 95.3
General
Fittings

P2265 45° 311⁄16


0.79 93.7
Pipe/Conduit
Supports

P1045 Wt/100 pcs: 55 Lbs (24.9 kg) P1347 Wt/100 pcs: 55 Lbs (24.9 kg)
Electrical
Fittings
Concrete
Inserts

1 5⁄8"
(41.3)
11⁄4" Framing

1
1 ⁄16" 2 1⁄8"
System

(27.0) (54.0)
1 5⁄8" 1 5⁄8"
(41.3) (41.3)
⁄16" Framing
System

P1453 Wt/100 pcs: 70 Lbs (31.8 kg) P1454 Wt/100 pcs: 38 Lbs (17.2 kg)
13
Fiberglass
System

P1001
P5000
1
Splice ⁄4"
(6.4)
Offset
Special
Metals

3 1⁄4"
(82.6)
PrimeAngle
System

1 7⁄8" 3 15 32 "
(47.6)
(88.1)
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)
9

102 General Fittings


“Z” Shape Fittings

P1479A thru P1479E P1730 Wt/100 pcs: 54 Lbs (24.5 kg)

Channel
15⁄8"
1 5⁄8"
(41.3) 1 5⁄8" 1 5⁄8"
(41.3) (41.3)
1 7⁄8"

Telestrut
System
(47.6)

A Part “A” Wt/100 pcs


Number In (mm) Lbs (kg)

Hardware
Nuts &
P1479A 4 81
101.6 36.7
P1479B 5 92
127.0 41.7
P1479C 6 104

General
Fittings
152.4 47.2 Tapped
5
P1479D 7 115 ⁄16" - 18 Thd.
177.8 52.2
P1479E 8 127

Pipe/Conduit
203.2 57.6

Supports
P1734 Wt/100 pcs: 70 Lbs (31.8 kg) P1736 Wt/100 pcs: 70 Lbs (31.8 Kg)

1 5⁄8" 1 5⁄8" 3 1⁄2" 3 1⁄2"

Electrical
Fittings
(41.3) (41.3) (88.9) (88.9)
1 7⁄8" 1 7⁄8"
(47.6) (47.6)
1 7⁄8" 1 7⁄8"
(47.6) (47.6 )

Concrete
Inserts
11⁄4" Framing
System
Tapped
5
⁄16" - 18 Thd.

Framing
System
P2360 Wt/100 pcs: 9 Lbs (4.1 kg) P5560 Wt/100 pcs: 11 Lbs (5.0 kg)

13⁄16"
Fiberglass
13
⁄16"

System
13
⁄16" (20.6)
(20.6)
9
⁄32" (7.1) Hole
1
⁄8" (3.2) Thick
Special

9
⁄32" (7.1) Hole
Metals

1
⁄8" (3.2) Thick
P1000
P1100
PrimeAngle

P2000 P5500
System
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: 9⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)

General Fittings 103


® “Z” & “U” Shape Fittings

P3045 Wt/100 pcs: 53 Lbs (24.0 kg) P3345 Wt/100 pcs: 47 Lbs (21.3 kg)
Channel
15⁄8"

P3000
Telestrut
System

P3300
1 3⁄8"
(34.9)

7
1 1⁄16" 1 1⁄16" ⁄8"
Hardware

(27.0) (27.0) (22.2)


Nuts &

3 3⁄4" 3 3⁄4"
General
Fittings

(95.3) (95.3)
Pipe/Conduit
Supports

P4045 Wt/100 pcs: 47 Lbs (21.3 kg) P5545 Wt/100 pcs: 67 Lbs (30.4 kg)

P5500
Electrical
Fittings

P4000
P4100 2 7⁄16"
(61.9)
Concrete
Inserts

13
1 1⁄16" ⁄16"
(27.0) (20.6) 1 1⁄16"
(27.0)
11⁄4" Framing

3 3⁄4"
System

(95.3) 3 3⁄4"
(95.3)
⁄16" Framing
System

P2469 Wt/100 pcs: 93 Lbs (42.2 kg) P2800


P1001A3 (shown)
13

or P5501
1 5⁄8" Part Bolt Size Wt/100 pcs
Fiberglass
System

(41.3) Number In Lbs (kg)


1
P2800-25 ⁄4" 14
6.4
3
P2800-37 ⁄8" 14
6.4
Special
Metals

15
⁄32" P2800-50 1
⁄2" 13
(11.9) 5.9
5
4 7⁄8" 11 Ga. P2800-62 ⁄7" 13
(123.8) 5.9
PrimeAngle

3
P2800-75 ⁄4" 13
System

1
1 ⁄16" 5.9
2 1⁄8"
(27.0) (54.0)
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)
9

104 General Fittings


“U” Shape Fittings

P1320 Wt/100 pcs: 63 Lbs (28.6 kg) P1363A thru P1363E

Channel
15⁄8"
Part “A” Wt/100 pcs

Telestrut
1 7⁄8"

System
Number In (mm) Lbs (kg)
(47.6)
P1363A 4 78
1 7⁄8"
(47.6) 101.6 35.4
P1363B 5 89
127.0 40.4

Hardware
Nuts &
1 P1363C 6 101
⁄2" - 13 Thd. 152.4 45.8
A P1363D 7 112
3
⁄4" 177.8 50.8
(19.1)

General
P1363E 8 124

Fittings
5 203.2 56.2
2 ⁄32"
(54.8)

Pipe/Conduit
Supports
P1376 Wt/100 pcs: 128 Lbs (58.1 kg) P4376 Wt/100 pcs: 85 Lbs (38.6 kg)

Electrical
P3300

Fittings
P4000
P4100

3 1⁄ 2"

Concrete
Inserts
(88.9) 3 1⁄2"
(88.9)

11⁄4" Framing
System
Framing
System
P1376A Wt/100 pcs: 197 Lbs (89.4 kg) P4376A Wt/100 pcs: 130 Lbs (59.0 kg)

13⁄16"
P3300
P4000

Fiberglass
P4100

5 3⁄8" System
(136.5)
5 3⁄8"
Special
Metals

(136.5)
PrimeAngle
System
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: 9⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)

General Fittings 105


® “U” Shape Fittings

P1377, P4377, P5077, P5577


Channel
15⁄8"

A
Telestrut
System

Part For Use Wt/100 pcs


Number With Lbs (kg)
P1377 P1000, P1100, P2000 265
Hardware

120.2
Nuts &

1
7 ⁄4" P4377 P3300, P4000, P4100 176
(184.2)
79.8
P5077 P5000 390
176.9
General
Fittings

P5577 P5500 310


140.6
Pipe/Conduit
Supports

P1047 Wt/100 pcs: 88 Lbs (39.9 kg) P3047 Wt/100 pcs: 84 Lbs (38.1 kg)
Electrical

5 3⁄8"
Fittings

(136.5)
5 3⁄8"
(136.5)
1 5⁄8" 1 3⁄8"
(41.3) (34.9)
21
1 2132 " 1 32 "
(42.1)
Concrete

(42.1)
Inserts
11⁄4" Framing
System

P3000
⁄16" Framing
System

P4047 Wt/100 pcs: 71 Lbs (32.2 kg)


P1455 Wt/100 pcs: 58 Lbs (26.3 kg)
13

1
⁄4" (6.4) Plate
5 3⁄8"
(136.5)
Fiberglass
System

1 2132 " 1
⁄4" (6.4) Offset
(42.1) 13
⁄16"
(20.6)
Special
Metals

P3300
PrimeAngle
System

P4000 5 5⁄16"
P4100 (134.9)
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)
9

106 General Fittings


“U” Shape Fittings

P5547 Wt/100 pcs: 108 Lbs (49.0 kg) P1383 Wt/100 pcs: 95 Lbs (43.1 kg)

Channel
15⁄8"
5 3⁄8" 5 3⁄8"
(136.5) (136.5)

Telestrut
1 7⁄8"

System
2 7⁄16"
1 21
32 " (61.9) (47.6)
(42.1)
1 2132 "
(42.1)

Hardware
Nuts &
General
Fittings
P5500

Pipe/Conduit
Supports
P1732 Wt/100 pcs: 88 Lbs (39.9 kg) P2237 Wt/100 pcs: 18 Lbs (8.2 kg)

5 3⁄8"
(136.5)
1 2132 " 13
⁄32"

Electrical
1 5⁄8"

Fittings
(42.1) (10.3) 3 11⁄16"
(41.3) 5 (93.7)
1 ⁄8"
(41.3)
1 11⁄16"
(42.9)
Tapped

Concrete
Inserts
5
⁄16" - 18 Thd.
All Holes 9⁄32" (7.1) Dia.

3
⁄4"

11⁄4" Framing
(19.1)

System
Material: 1⁄8" (3.2) thick.

P5543 Wt/100 pcs: 97 Lbs (44.0 kg) P1048, P1049, P1050

Framing
System
11
6 32 " A
(161.1)

13⁄16"
5
1 7⁄8" 1 ⁄8"
(47.6) (41.3)
2 15 32 "
(62.7)

Fiberglass
System
B
1 1⁄2"
(38.1)
Special
Metals

Part “A” “B” Wt/100 pcs


Number In (mm) In (mm) Lbs (kg)
P1048 71⁄4 41⁄8 105
P5500 184.2 104.8 47.6
PrimeAngle

P1049 81⁄2 53⁄8 120


System

215.9 136.5 54.4


P1050 103⁄8 71⁄4 130
263.5 184.2 59.0
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: 9⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)

General Fittings 107


® “U” Shape Fittings

P1043A Wt/100 pcs: 105 Lbs (47.6 kg) P1737 Wt/100 pcs: 128 Lbs (58.1 kg)
Channel
15⁄8"

5 3⁄8"
7" (136.5)
Telestrut

(177.8) 1 5⁄8"
System

(41.3)
3 9⁄32" 1 2132 " 3 1⁄4"
(83.3) (42.1) (82.6)
Hardware
Nuts &

P1001A
General
Fittings

1 5⁄8"
(41.3) P1001(shown), P1101,
P2001, P4004 or P5000
Pipe/Conduit
Supports

P2473 Wt/100 pcs: 197 Lbs (89.4 kg) P4043 Wt/100 pcs: 106 Lbs (48.1 kg)

P1001A3 (shown) 7"


Electrical

(177.8)
Fittings

or P5501
3 9⁄32"
(83.3) 1 5⁄8"
(41.3)
Concrete
Inserts

4 7⁄8"
(123.8)
11⁄4" Framing
System

1 7⁄8"
(47.6) P4004 (shown), P1001,
P1101, P2001, or P5000
⁄16" Framing
System

P1044 Wt/100 pcs: 70 Lbs (31.8 kg) P1973 Wt/100 pcs: 53 Lbs (24.0 kg)
13

1 7⁄8" 13
⁄16"
Fiberglass
System

(47.6) (20.6)

P1001 (shown),
P1101, P2001 2 1⁄4"
3 2532 " (57.2)
or P4004
(96.0)
Special
Metals

1 1⁄16"
(27.0)
1 5⁄8" 1 5⁄8"
1 2132 " (41.3) (41.3)
PrimeAngle

(42.1)
System
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)
9

108 General Fittings


“U” & Wing Shape Fittings

P2326 Wt/100 pcs: 171 Lbs (77.6 kg) P2328 Wt/100 pcs: 209 Lbs (94.8 kg)

Channel
15⁄8"
P1000 (shown), P1100, P1001(shown), P1101,
3 1⁄2" P2000, P4001 or P4101 3 1⁄2" P2001, P4004 or P5000
(88.9) (88.9)

Telestrut
System
1 7⁄8"
(47.6) 1 7⁄8"

Hardware
(47.6)

Nuts &
3 9⁄32"
1 2132 " (83.3)
(42.1)

General
Fittings
5 3⁄8" 7"
(177.8)
(136.5)

Pipe/Conduit
Supports
P2329 Wt/100 pcs: 257 Lbs (116.6 kg) P1046A Wt/100 pcs: 76 Lbs (34.5 kg)

P1001(shown), P1101,
3 1⁄2" P2001, P4004 or P5000
(88.9)

Electrical
Fittings
Concrete
Inserts
3 1⁄2"
(88.9)
4 1⁄32"
(102.4) 1 7⁄8"
(47.6) 1 5 64 "

11⁄4" Framing
(27.4)

System
5 3 ⁄8 "
1 2132 "
(136.5) (42.1)

Framing
System
P2341 R-L Wt/100 pcs: 60 Lbs (27.2 kg) P2472 R-L Wt/100 pcs: 75 Lbs (34.0 kg)

13⁄16"
1 7⁄8"
(47.6)
7
1 ⁄8"
(47.6)

Fiberglass
2" System
(50.8)
Special

11 5
1 ⁄16" 1 ⁄ 8"
Metals

(42.9) (41.3)

Note: Hole
on back flange
PrimeAngle

not shown 1 5⁄8"


System

(41.3)
R - As shown 1 21 32 " R - As shown
L - Opposite hand (42.1) L - Opposite hand
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: 9⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)

General Fittings 109


® Wing Shape Fittings

P2343 R-L Wt/100 pcs: 119 Lbs (54.0 kg) P2223 Wt/100 pcs: 76 Lbs (34.5 kg)
Channel
15⁄8"

3 3⁄4"
(95.3) 1 7⁄8"
(47.6)
Telestrut
System
Hardware
Nuts &

3 1⁄2"
(88.9) 2"
General
Fittings

(50.8)

R - As shown
L - Opposite hand
Pipe/Conduit
Supports

P2224 Wt/100 pcs: 115 Lbs (52.2 kg) P2225 Wt/100 pcs: 155 Lbs (70.3 kg)

1 7⁄8" 3 3⁄4"
(47.6)
Electrical

(95.3)
Fittings
Concrete
Inserts

3 7⁄8"
3 7⁄8" (98.4)
(98.4)
11⁄4" Framing
System
⁄16" Framing
System

P2227 Wt/100 pcs: 113 Lbs (51.3 kg) P2228 Wt/100 pcs: 177 Lbs (80.3 kg)
13

5 13 32 "
5 13 32 " (137.3)
(137.3)
1 7⁄8"
Fiberglass
System

(47.6)
1 7⁄8"
(47.6)

3 7⁄8"
2" (98.4)
Special

(50.8)
Metals
PrimeAngle
System

1 21 32 " 1 5⁄8" 1 5⁄8"


(42.1) (41.3) 1 21 32 " (41.3)
(42.1)
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)
9

110 General Fittings


Wing Shape Fittings

P2229 Wt/100 pcs: 230 Lbs (104.3 kg) P2345 Wt/100 pcs: 93 Lbs (42.2 kg)

Channel
15⁄8"
3 3⁄4"
(95.3) 5 13 32 "
(137.3)

Telestrut
System
1 7 ⁄8 "
(47.6)
7
3 ⁄8"
(98.4)

Hardware
2"

Nuts &
(50.8)

General
Fittings
9 5⁄32"
(232.6) 1 21 32 " 1 5⁄8"
5 (42.1) (41.3)
1 21 32 " 1 ⁄8"
(42.1) (41.3)

Pipe/Conduit
Supports
P2346 Wt/100 pcs: 150 Lbs (68.0 kg) P2347 Wt/100 pcs: 193 Lbs (87.5 kg)

5 13 32 "
(137.3) 3 3⁄4"
(95.3)

Electrical
Fittings
1 7⁄8"
(47.6) 9 5⁄32"
(232.6)

Concrete
Inserts
3 7⁄8" 3 7⁄8"
(98.4)
(98.4)

11⁄4" Framing
System
1 5⁄8" 1 21 32 " 1 5⁄8"
1 21 32 " (41.3) (42.1)
(42.1) (41.3)

Framing
System
P2344 R-L Wt/100 pcs: 176 Lbs (79.8 kg) P2226 Wt/100 pcs: 217 Lbs (98.4 kg)

13⁄16"
3 3⁄4" 3 3⁄4"
(95.3) (95.3)

Fiberglass
System
3 7⁄8"
Special
Metals

(98.4)
3 7⁄8"
(98.4)
PrimeAngle
System

R - As shown
L - Opposite hand
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: 9⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)

General Fittings 111


® Wing Shape Fittings

P2230 Wt/100 pcs: 310 Lbs (140.6 kg) P2245 Wt/100 pcs: 315 Lbs (142.9 kg)
Channel
15⁄8"

3 3⁄4" 3 3⁄4"
9 5⁄32" (95.3) (95.3)
(232.6) 5 3⁄ 8"
Telestrut
System

(136.5)

3 3⁄ 4"
Hardware

3 7 ⁄8 "
Nuts &

(98.4) (95.3)

Fitting notched for


General
Fittings

continuous vertical.
1 21 32 " 1 5 ⁄8 "
(42.1) (41.3)
Pipe/Conduit
Supports

P2348 Wt/100 pcs: 274 Lbs (124.3 kg) P2453 Wt/100 pcs: 116 Lbs (52.6 kg)

3 3⁄4"
(95.3)
Electrical

9 5⁄32"
Fittings

(232.6)
Concrete

3 7⁄8"
Inserts

(98.4)
11⁄4" Framing

1 15⁄16"
System

(49.2)
1 21 32 " 1 5⁄8"
(42.1) (41.3) 1 11⁄16" 3 1⁄8"
(42.9) (79.4)
⁄16" Framing
System

Wt/100 pcs: 297 Lbs (134.8 kg)


P1887
13

1 5⁄8" 1 5 ⁄8 "
(41.3) (41.3)
Fiberglass
System

3 1 ⁄2 "
(88.9)
4 Holes
Special
Metals

7
⁄16" (11.1) Dia.

5
PrimeAngle

⁄8 " 5
⁄8 "
5" (15.9)
System

(15.9) 5"
(127.0) (127.0)
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)
9

112 General Fittings


Post Bases

P2941, P2942 Wt/100 pcs: 358 Lbs (162.4 kg)

Channel
15⁄8"
1" 1" 1" 1"

Telestrut
(25.4) (25.4) (25.4) (25.4)

System
2" 2"
3 1⁄2" (50.8) (50.8)
(88.9)

Hardware
4"

Nuts &
(101.6)
P2941 2 Holes 11⁄16" (17.5) Dia. P2942
6"

General
Fittings
(152.4)

Pipe/Conduit
Supports
P2072, P2072 SQ Wt/100 pcs: 307 Lbs (139.3 kg)
7 7
4 Holes ⁄8" ⁄8"
3
⁄4" (19.1) Dia. (22.2) (22.2)
6" 4 Holes

Electrical
3
(152.4) ⁄4" (19.1) Dia.

Fittings
1 5⁄8" 7
⁄8"
(41.3) 3"
(76.2) (22.2) 3"
6"
(152.4) (76.2) 6"
3" (152.4)
(76.2) 3"

Concrete
1
⁄4"

Inserts
7
⁄8" (76.2)
(6.4)
3" 3" (22.2)
(76.2) (76.2) 3" 3"
(76.2) (76.2)
6"

11⁄4" Framing
(152.4)

System
6"
P2072 (152.4)
P2072 SQ

Framing
System
P2072A, P2072A SQ Wt/100 pcs: 373 Lbs (169.2 kg)

13⁄16"
7 7
⁄8" ⁄8"
4 Holes
(22.2) (22.2)
3
⁄4" (19.1) Dia. 4 Holes
6" 3
⁄4" (19.1) Dia.

Fiberglass
7
(152.4) ⁄8"

System
3" (22.2) 3"
(76.2)
6" (76.2) 6"
3 1⁄2" (152.4) (152.4)
(88.9) 3" 3"
(76.2) 7 (76.2)
⁄8"
Special
Metals

1 3" 3" (22.2)


⁄4" 3" 3"
(6.4) (76.2) (76.2)
(76.2) (76.2)
6"
PrimeAngle

(152.4)
6"
System

(152.4)
P2072A
P2072A SQ
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: 9⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)

General Fittings 113


® Post Bases

P2073 Wt/100 pcs: 325 Lbs (147.4 kg)


Channel
15⁄8"

7 7
⁄8" ⁄8"
4 Holes
3
(22.2) (22.2)
P1001A ⁄4" (19.1) Dia. 4 Holes
6" 3
⁄4" (19.1) Dia.
Telestrut

5
1 ⁄8" (152.4) 7
System

⁄8"
(41.3) 3" (22.2) 3"
(76.2)
6" (76.2) 6"
(152.4) (152.4)
3" 3"
(76.2)
Hardware

1
⁄4" 7
⁄8" (76.2)
Nuts &

(6.4) (22.2)
3" 3" 3" 3"
(76.2) (76.2)
(76.2) (76.2)
6"
General
Fittings

(152.4)
6"
P2073 (152.4)

P2073 SQ
Pipe/Conduit
Supports

P2073A Wt/100 pcs: 408 Lbs (185.1 kg)

7 7
⁄8" ⁄8"
P1001A
4 Holes (22.2) (22.2)
4 Holes
Electrical
Fittings

3
⁄4" (19.1) Dia. 3
⁄4" (19.1) Dia.
6" 7
⁄8"
(152.4)
3" (22.2) 3"
3 1⁄2" (76.2) (76.2) 6"
(88.9) 6" (152.4)
Concrete

(152.4) 3"
Inserts

3"
(76.2) 7
⁄8" (76.2)
1
⁄4" (22.2)
3" 3" 3" 3"
(6.4)
(76.2) (76.2) (76.2) (76.2)
11⁄4" Framing
System

6"
(152.4) 6"
(152.4)
P2073A
P2073A SQ
⁄16" Framing
System
13
Fiberglass
System
Special
Metals
PrimeAngle
System
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)
9

114 General Fittings


Brackets

P1769 Wt/100 pcs: 174 Lbs (78.9 kg) P1771 Wt/100 pcs: 206 Lbs (93.4 kg)

Channel
15⁄8"
1 3⁄16" 1 1⁄16"
1 1⁄16" 1 3⁄16"

Telestrut
System
(30.2) (30.2) (27.0)
(27.0) 10 1⁄2"
8 1⁄2" 4 3⁄8"
(266.7)
6 1⁄8" (215.9) (111.1)
(155.6) 3 3 ⁄4"
(95.3)
1 3⁄16" 1 3⁄16"

Hardware
(30.2) (30.2)

Nuts &
4" 4"
1 5⁄8" 1 5⁄8" (101.6)
(101.6) (41.3) (41.3)
5
⁄16" (7.9) Thick

General
Fittings
Vertical Uniform Vertical Uniform
Channel Design Load Channel Design Load

Pipe/Conduit
Supports
Part No. Gauge Lbs (kg) Part No. Gauge Lbs (kg)
P1000 12 800 P1000 12 800
362.9 362.9
P1100 14 600 P1100 14 600
272.2 272.2
P2000 16 400 P2000 16 400

Electrical
Fittings
181.4 181.4

Safety Factor 21⁄2 Safety Factor 21⁄2

Material: 1⁄4" (6.4) thick steel. Material: 1⁄4" (6.4) thick steel.

Concrete
Inserts
P1773 Wt/100 pcs: 264 Lbs (119.7 kg) P1775 Wt/100 pcs: 295 Lbs (133.8 kg)

11⁄4" Framing
1 1⁄16" 1 3⁄16" 1 3⁄16" 1 1⁄16"
(30.2)

System
(27.0) 1
3 ⁄4" 12 1⁄2" (30.2) (27.0)
(82.6) 3 1⁄8" (317.5) 3 1⁄4"
(79.4) 3 1⁄8" (82.6)
3 3⁄4" 1 (79.4)
(95.3) 14 ⁄2" 5 3⁄4"
(368.3)
(146.1)
1 3⁄16"

Framing
(30.2) 1 3⁄16"

System
1 5⁄8" (30.2)
2 1⁄2" (41.3) 1 5⁄8" 2 1⁄2"
(41.3) (63.5)
(63.5)

13⁄16"
5
⁄16" (7.9) Thick

Fiberglass
6" 6"

System
(152.4) (152.4)
Vertical Uniform Vertical Uniform
Channel Design Load Channel Design Load
Part No. Gauge Lbs (kg) Part No. Gauge Lbs (kg)
P1000 12 900
Special

P1000 12 900
Metals

408.2 408.2
P1100 14 800 P1100 14 800
362.9 362.9
P2000 16 450 P2000 16 450
PrimeAngle

204.1 204.1
System

Safety Factor 21⁄2 Safety Factor 21⁄2

Material: 1⁄4" (6.4) thick steel. Material: 1⁄4" (6.4) thick steel.
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: 9⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)

General Fittings 115


® Brackets

P1075 Wt/100 pcs: 229 Lbs (103.9 kg) P1593 Wt/100 pcs: 272 Lbs (123.4 kg)
Channel

1 1⁄16"
3
15⁄8"

(27.0) 4 ⁄ 4" 1 1⁄16"


(120.7) (27.0) 4 3 ⁄ 4"
(120.7)
Telestrut
System

5 7 ⁄ 8"
(149.2) 7 1⁄2"
(190.5)
3"
(76.2) P1000
Hardware
Nuts &

P1100
P2000 4 5⁄8" P1001
P4001 (117.5)
P1101
P5000
P2001
General
Fittings

Material: 1⁄4" (6.4) thick steel.


Pipe/Conduit

1 * Allowable moment for fitting only.


Material: ⁄4" (6.4) thick steel.
Supports

Channel may determine overall capacity.


* Allowable moment for fitting only.
Channel may determine overall capacity.

Vertical Allowable Vertical Allowable


Channel Moment* Channel Moment*
Electrical
Fittings

Part No. Gauge In-Lbs (N•M) Part No. Gauge In-Lbs (N•M)
P1000 12 5,100 P1000 12 13,000
576 1,469
P1100 14 4,400 P1100 14 9,100
Concrete

497 1,028
Inserts

P2000 16 3,200 P2000 16 6,500


362 734
Safety Factor 21⁄2 Safety Factor 21⁄2
11⁄4" Framing
System

P1777 Wt/100 pcs: 385 Lbs (174.6 kg)


⁄16" Framing
System

1 3⁄16"
1 1⁄16" (30.2)
(27.0)
13

5 1⁄4" 16 1⁄2" Vertical Uniform


(133.4) 3 1⁄8" (419.1)
(79.4) Channel Design Load
Fiberglass

Part No. Gauge Lbs (kg)


System

5 3⁄4"
(146.1) P1000 12 1,200
3
544.3
1 ⁄16" P1100 14 900
(30.2)
1
2 ⁄2" 5
408.2
1 ⁄8 "
Special
Metals

(63.5) (41.3) P2000 16 600


272.2
Safety Factor 21⁄2
6"
PrimeAngle

(152.4)
System

Material: 1⁄4" (6.4) thick steel.


Product
Index

Note
When used for mechanical supports, load capacities of brackets and fittings should be in compliance with the American Standard Code for Pressure Piping.

116 General Fittings


Brackets

P2491 R-L thru P2493 R-L

Channel
R - As shown; L - Opposite hand

15⁄8"
Material : 12 Gauge Steel.
Vertical Uniform Part Stamped “A” “B” Wt/100 pcs
Channel Design Load Number Ident. No. In (mm) In (mm) Lbs (kg)
5 Part No. Gauge Lbs (kg)
⁄8"

Telestrut
P2491 R-L 121892 R-L 6 115⁄16 67

System
(15.9) P1000 12 300
A 52.4 49.2 30.4
3 136.1 P2492 R-L 121893 R-L 8 27⁄16 92
⁄8" x 1"
(9.5 x 25.4) P1100 14 250 203.2 61.9 41.7
1" 113.4 P2493 R-L 121894 R-L 10 215⁄16 120

Hardware
(25.4) P2000 16 200 254.0 74.6 54.4

Nuts &
B
13 90.7
⁄16"
(20.6)
7
⁄16" Safety Factor - 21⁄2
(11.1) Dia. 1 5⁄8"
(41.3)

General
Fittings
9
⁄32" (7.1) Dia.

P2494 R-L thru P2499 R-L R - As shown; L - Opposite hand

Pipe/Conduit
Supports
Material : 12 Gauge Steel. Vertical Uniform Part Stamped “A” “B” Wt/100 pcs
Channel Design Load Number Ident. No. In (mm) In (mm) Lbs (kg)
Part No. Gauge Lbs (kg)
P2494 R-L 121895 R-L 12 37⁄16 152
P1000 12 300 304.8 87.3 68.9
136.1 P2495 R-L 121896 R-L 14 315⁄16 173
P1100 14 250 355.6 100.0 78.5

Electrical
Fittings
113.4 P2496 R-L 121897 R-L 16 47⁄16 223
P2000 16 200 406.4 112.7 101.2
A 90.7
3 P2497 R-L 121898 R-L 18 415⁄16 266
⁄8" x 1" 457.2 125.4 120.7
Safety Factor - 21⁄2
(9.5 x 25.4)

Concrete
P2498 R-L 121899 R-L 20 57⁄16 308

Inserts
B 5⁄8"
1" 508.0 138.1 139.7
(15.9) (25.4)
13 P2499 R-L 121900 R-L 22 515⁄16 355
⁄16" 558.8 150.8 161.0
7 (20.6)
⁄16" (11.1) Dia.
9
⁄32" (7.1) Dia.

11⁄4" Framing
1 5⁄8"

System
(41.3)

P2500 R-L thru P2503 R-L R - As shown; L - Opposite hand


Material : 12 Gauge Steel. Part Stamped “A” “B” Wt/100 pcs
Number Ident. No. In (mm) In (mm) Lbs (kg)

Framing
67⁄16

System
P2500 R-L 121901 R-L 24 400
609.6 163.5 181.4
P2501 R-L 121902 R-L 26 615⁄16 445

13⁄16"
660.4 176.2 201.8
P2502 R-L 121903 R-L 28 77⁄16 493
711.2 188.9 223.6

Fiberglass
System
P2503 R-L 121904 R-L 30 715⁄16 545
A 762.0 201.6 247.2
5
⁄8"
(15.9)
3 Vertical Uniform
⁄8" x 1"
Special

B
Metals

Channel Design Load


(9.5 x 25.4)
Part No. Gauge Lbs (kg)
1"
P1000 12 300
136.1
13
⁄16"
PrimeAngle

P1100 14 250
(20.6)
System

9
7 ⁄32" (7.1) Dia. 113.4
⁄16" (11.1) Dia.
1 5⁄8" P2000 16 200
(41.3) 90.7
Safety Factor - 21⁄2
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: 9⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)

General Fittings 117


® Brackets

P2547 thru P2551 Cable Tray Bracket P2944, P2945, P2946, P2947
Channel
15⁄8"

2"
(50.8)
A 11
⁄16" 3
(17.5) ⁄8 "
Telestrut

(9.5)
System

9
⁄16"
(14.3)

B
Hardware

31⁄4"
Nuts &

(82.6)
45⁄8"
(117.5)

A
General

11
Fittings

⁄16"
(17.5)
Uniform Uniform
Part “A” “B” Wt/100 pcs Load* Part “A” Wt/100 pcs Load*
Number In (mm) In (mm) Lbs (kg) Lbs (kg) Number In (mm) Lbs (kg) Lbs (kg)
Pipe/Conduit

83⁄4
Supports

P2547 15 420 1,000 P2944 6 185 1200


381.0 222.3 190.5 453.6 152.4 83.9 544.3
P2548 21 83⁄4 628 1,000 P2945 12 293 600
533.4 222.3 284.9 453.6 304.8 132.9 272.2
P2549 27 111⁄4 860 900 P2946 18 401 400
685.8 285.8 390.1 408.2 457.2 181.9 181.4
Electrical
Fittings

P2550 33 111⁄4 1010 900 P2947 24 509 300


838.2 285.8 458.1 408.2 609.6 230.9 136.1
P2551 39 16 1257 800
990.6 406.4 683.3 362.9 Safety Factor 21⁄2
* Mounted on 12 Ga. Channel
Concrete
Inserts

P2542 thru P2546 Vertical Uniform


Part “A” Wt/100 pcs Channel Design Load
Number In (mm) Lbs (kg) Part No. Gauge Lbs (kg)
11⁄4" Framing

P1000 12 2,000
907.2
System

P2542 12 502 P1100 14 1,400


2" (50.8) 304.8 227.7 635.0
P2000 16 1,000
13
453.6
⁄16" P1000 12 1,300
(20.6)
⁄16" Framing

589.7
System

9
⁄16" A P2543 18 692 P1100 14 900
(14.3) 457.2 313.9 408.2
P2000 16 650
294.8
13

45⁄8" P1000 12 1,000


(117.5) 453.6
Fiberglass

P2544 24 882 P1100 14 700


System

61⁄4" 609.6 400.1 317.5


(158.8) P2000 16 500
226.8
P1000 12 800
P1001 362.9
3
⁄8"
Special
Metals

13
⁄16" (9.5) P2545 30 1,072 P1100 14 560
(20.6) 762.0 486.3 254.0
P2000 16 400
181.4
P1000 12 650
PrimeAngle

294.8
System

P2546 36 1,262 P1100 14 450


914.4 572.4 204.1
P2000 16 320
145.1
Product
Index

Note
When used for mechanical supports, load capacities of brackets and fittings should be in compliance with the American Standard Code for Pressure Piping.

118 General Fittings


Brackets

P2231, P2232 Vertical Uniform

Channel
Part “A” Wt/100 pcs Channel Design Load

15⁄8"
Number In (mm) Lbs (kg) Part No. Gauge Lbs (kg)
1 P1000 12 1,600
⁄4"
(6.4) 725.7

Telestrut
System
P2231 6 191 P1100 14 1,200
3 1⁄2"
(88.9) 152.4 86.6 544.3
P2000 16 800
362.9
P1000 12 800

Hardware
Nuts &
362.9
13 P2232 12 292 P1100 14 600
⁄16" 304.8 132.4 272.2
(20.6) A P2000 16 400
181.4

General
Fittings
Safety Factor - 21⁄2

P2233, P2234 Vertical Uniform


Part “A” Wt/100 pcs Channel Design Load

Pipe/Conduit
Number In (mm) Lbs (kg) Part No. Gauge Lbs (kg)

Supports
1 P1000 12 600
⁄4"
(6.4) 272.2
P2233 18 436 P1100 14 450
457.2 197.8 204.1
5 3⁄8" P2000 16 300

Electrical
(136.5)

Fittings
136.1
P1000 12 450
204.1
P2234 24 536 P1100 14 330
A 609.6 243.1 149.7

Concrete
Inserts
13 P2000 16 220
⁄16"
(20.6) 99.8
Safety Factor - 21⁄2

P2513 thru P2516

11⁄4" Framing
Vertical Uniform

System
Part “A” Wt/100 pcs Channel Design Load
Number In (mm) Lbs (kg) Part No. Gauge Lbs (kg)
P1000 12 1,200
544.3
2"
(50.8) P2513 6 161 P1100 14 800
152.4 73.0 362.9

Framing
P2000 16 600

System
1
⁄4"
(6.4) 272.2
P1000 12 600

13⁄16"
3 3⁄4" 272.2
(95.3)
P2514 12 261 P1100 14 400
304.8 118.4 181.4

Fiberglass
P2000 16 300

System
136.1
P1000 12 400
181.4
A P2515 18 361 P1100 14 270
457.2 163.7 122.5
Special
Metals

P2000 16 200
90.7
P1000 12 300
136.1
PrimeAngle

P2516 24 461 P1100 14 200


System

609.6 209.1 90.7


When installed in inverted position
use 60% of loads shown. P2000 16 150
68.0
Safety Factor - 21⁄2
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: 9⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)

General Fittings 119


® Brackets

P2231A, P2232A Vertical Uniform


Channel

Part “A” Wt/100 pcs Channel Design Load


15⁄8"

Number In (mm) Lbs (kg) Part No. Gauge Lbs (kg)


1
⁄4" P1000 12 1,600
(6.4)
725.7
Telestrut
System

3 1⁄2" P2231A 6 191 P1100 14 1,200


(88.9) 152.4 86.6 544.3
P2000 16 800
362.9
P1000 12 800
Hardware
Nuts &

13
⁄16" 362.9
(20.6) P2232A 12 292 P1100 14 600
A
304.8 132.4 272.2
P2000 16 400
181.4
General
Fittings

Safety Factor - 21⁄2

P2233A, P2234A Vertical Uniform


Part “A” Wt/100 pcs Channel Design Load
Pipe/Conduit

Number In (mm) Lbs (kg) Part No. Gauge Lbs (kg)


Supports

1
⁄4" P1000 12 600
(6.4) 272.2
P2233A 18 436 P1100 14 450
457.2 197.8 204.1
5 3⁄8" P2000 16 300
Electrical

(136.5)
Fittings

136.1
P1000 12 450
204.1
P2234A 24 536 P1100 14 330
13 A 609.6 243.1 149.7
⁄16"
Concrete
Inserts

(20.6) P2000 16 220


99.8
Safety Factor 21⁄2

P2513A thru P2516A Vertical Uniform


11⁄4" Framing

Part “A” Wt/100 pcs Channel Design Load


System

Number In (mm) Lbs (kg) Part No. Gauge Lbs (kg)


2"
(50.8) P1000 12 1,200
544.3
1 P2513A 6 161 P1100 14 800
⁄ 4" 152.4 73.0 362.9
⁄16" Framing

(6.4)
P2000 16 600
System

3 3⁄ 4 " 272.2
(95.3)
P1000 12 600
272.2
13

P2514A 12 261 P1100 14 400


304.8 118.4 181.4
Fiberglass

P2000 16 300
System

136.1
P1000 12 400
A 181.4
P2515A 18 361 P1100 14 270
457.2 163.7 122.5
Special
Metals

P2000 16 200
90.7
P1000 12 300
136.1
PrimeAngle

P2516A 24 461 P1100 14 200


System

When installed in inverted position 609.6 209.1 90.7


use 60% of loads shown.
P2000 16 150
68.0
Safety Factor 21⁄2
Product
Index

Note
When used for mechanical supports, load capacities of brackets and fittings should be in compliance with the American Standard Code for Pressure Piping.

120 General Fittings


Brace Fittings

P2452 Knee Brace

Channel
15⁄8"
1 5⁄8" Wt/100 pcs: 277 Lbs (125.6 kg)
(41.3)

Telestrut
System
13 5⁄8"
(346.1)
16 5⁄8"

Hardware
(422.3)

Nuts &
General
Fittings
1 5⁄8"
(41.3)
13 5⁄8"
(346.1)
Design Axial Load

Pipe/Conduit
1200 Lbs (544.3 kg)

Supports
1
Material: ⁄4" (6.4) thick steel.

P2458-18 thru P2458-36 Tubular Knee Braces

Electrical
Fittings
Part “A” Wt/100 pcs
Number In (mm) Lbs (kg)
P2458-18 18 146
A

Concrete
457.2 66.2

Inserts
45°
P2458-24 24 186
609.6 84.4
P2458-30 30 227
762.0 103.0

11⁄4" Framing
P2458-36 36 267

System
914.4 121.1

WIDTH

Framing
1
0 /2' 1' 11/2' 2' 21/2' 3'

System
13
⁄16"
8

(20.6)
-1

1
/2'

13⁄16"
58

4
-2
24
58

0
-3
P
24
58

6
-3

1 5⁄8"
P
24

1'
58

(41.3)
P

Fiberglass
24

System
HEIGHT

1 17 32 "
(38.9) 11/2'

1" 17
32 " Dia Hole
(25.4) (13.5) 2'
Special
Metals

21/2'
Design Loads
Compression = 1500 Lbs (680.4 kg)
Tension = 300 Lbs (136.1 kg)
PrimeAngle
System
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: 9⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)

General Fittings 121


® Brace Fittings

P2459-36 thru P2459-96 Tubular Back Braces


Channel
15⁄8"

Part “A” Wt/100 pcs


Number In (mm) Lbs (kg)
8'
P2459-36 36 255
8 P
Telestrut

914.4 115.7 7'


System

24
7 P 59
P2459-42 42 296

BRACING HEIGHT
6' 24 -9
59 6
1,066.8 134.3 6 P
24 -8
P2459-48 48 336 5' 5 P 59 4
41/2 P 24 -7
1,219.2 152.4 4' 5 2
Hardware

4 P 245 9 -
Nuts &

P2459-54 54 377 1 2 60
3 /2 P 45 -5 9
1,371.6 171.0 3' 3 P 2 2459 9-48 4
45 -4
2
P2459-60 60 418 2'
9-
36

°
1,524.0 189.6

60
P2459-72 72 499 1'
°
General
Fittings

1,828.8 226.3 30
P2459-84 84 580 1' 2' 3' 4' 5' 6' 7'
2,133.6 263.1 CENTER TO CENTER OF UPRIGHT
P2459-96 96 661
Pipe/Conduit

2,438.4 299.8
Supports

A
Electrical
Fittings

1. The vertical lines of the graph correspond to the center to 17⁄32" (13.5) Dia. Hole
center line dimension of the uprights.

1 17⁄32" 1"
Concrete

2. Along this vertical line locate the (maximum usable)


Inserts

(25.4)
horizontal bracing height line. (38.9)

3. The arc line that intersects the point formed by the


intersection of the two lines, indicates the brace required. 1 5⁄8"
11⁄4" Framing

(41.3)
System

4. 60° - 30° maximum, minimum brace angles are indicated for


maximum effect. 13
⁄16"
(20.6)
⁄16" Framing
System

P2815 Adjustable Brace Fitting P2815D Adjustable Brace Fitting


Wt/100 pcs: 307 Lbs (139.3 kg) Wt/100 pcs: 497 Lbs (225.4 kg)
13
Fiberglass
System

13
⁄16"
(20.6)
13
⁄16"
5 7⁄8" 1 7⁄8" 1 7⁄8 " (20.6)
(149.2) (47.6) (46.7) 7
1 ⁄ 8" 1 7⁄8"
(47.6) (47.6)
Special
Metals

13 13
⁄16" 30° (.17π) ⁄16"
(20.6) (20.6)
Min. 30°
(.17π)
Min. 5 7 ⁄ 8"
PrimeAngle

13
⁄16" (149.2)
System

1 (20.6)
1 ⁄16" 3 3⁄4" 1 1⁄16"
(27.0) (95.3) (27.0) 2 3⁄8"
13
⁄16" (60.3)
3
5 ⁄8" (20.6)
(136.5) 4"
(101.6)
Product
Index

Note
When used for mechanical supports, load capacities of brackets and fittings should be in compliance with the American Standard Code for Pressure Piping.

122 General Fittings


Beam Clamps

P2897 21⁄16" Wt/100 pcs: 33 Lbs (15.0 kg) FM FM Approved Applications

Channel
(52)

15⁄8"
Telestrut
System
11⁄16"
(27)
Max. FM 21⁄4"
11
⁄16" (57)

Hardware
(17)

Nuts &
25° Max.
25° Max. 25° Max.

21⁄4" Other (Non - FM Approved) Applications


(57) Safety Factor 4

General
Torque: 13 Ft-Lbs (18 N•m)

Fittings
90°
3
⁄8" Threaded

Pipe/Conduit
Rod

Supports
Design Load (Safety Factor of 4)
(angles ≤ 25°) - 550 Lbs (250Kg) 25° to 45°
(angles > 25°) - 330 Lbs (150Kg) 25° to 45°

Electrical
P2784

Fittings
Part For Use Load Wt/100 pcs

Concrete
3"

Inserts
(76.2) Number With Lbs (kg) Lbs (kg)
P2784-1 P1000, P1100, P2000 1,200 175
1 1⁄4" 1 1⁄4" 544 79.3
(31.8) (31.8) P2784-2 P1001, P1101, P2001 1,200 179

11⁄4" Framing
544 81.1

System
P2784-3 P5001,P5501 1,200 180
544 81.5

5 1⁄8"
(130.2)

Framing
System
PFL2-37 Swiftgrip
Wt/100 pcs: 26 Lbs (11.9 kg)

13⁄16"
FM
Designed to significantly reduce installation time, while offering greater
performance than cast beam clamps, the Swiftgrip enables connection

Fiberglass
of drop rod to beam in one simple operation.

System
Ideal for the suspension of building services equipment including
1
⁄8" to 3⁄4" heating, ventilating and air conditioning equipment; pipework; fire
(3.2 to 19.1) protection systems; electrical equipment and cable tray.
Special
Metals

Available finish choices are Stainless Steel or Perma-Gold™


Industry Standard Yellow Dichromate.
Design Load is 540 Lbs (245 kg).
PrimeAngle

Safety Factor is 4
System

Torque is 8 Ft/Lbs (10.8 N•m)


Rod Size is 3⁄8" (9.5mm)
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: 9⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)

General Fittings 123


® Beam Clamps

P2675 Wt/100 pcs: 33 Lbs (15.0 kg)


Channel
15⁄8"

7
⁄8"
Telestrut
System

(22.2)
1 7⁄8" 3
(47.6)
⁄8" X 1 1⁄2" Set Screw
and Nut Included
Hardware

Rod Size
Nuts &

up to 3⁄8"
5
⁄8"
(15.9)
Design Load
250 Lbs (113.4 kg) Design Load
General
Fittings

1
2 ⁄16" 150 Lbs (68.0 kg)
(52.4)

2 Holes 9⁄32" (7.1) Dia.


4 Holes 13⁄32" (10.3) Dia.
Pipe/Conduit
Supports

Rod Size up to 3⁄8" P3016-1024, or


P3016-1420
Channel Nut
Insulator
Electrical
Fittings

Clamp Materials: .105" (2.7) thick steel.


Clamp P2675 is designed for light duty rod suspension.
It also may be used with P3016-1024 or P3016-1420 nut as
illustrated above for mounting insulators, etc.
Concrete
Inserts

P2676 Wt/100 pcs: 72 Lbs (32.7 kg)


11⁄4" Framing
System

1 7⁄8"
(49.2)
1⁄2" X 2" Set Screw
2 5⁄8"
(66.7) and Nut Included
⁄16" Framing

1⁄8"(3.2) Thick
System

Rod Size
up to 1⁄2"
13

2 7⁄8" 7
⁄8" Design Load
Fiberglass

(73.0) (22.2) 300 Lbs (136.1 kg)


System

Swivel Nut and


Jam Nut not
Included Design Load
2 Holes
9 Rod Size up to 1⁄2" 500 Lbs (226.8 kg)
⁄16" (14.3) Dia.
Special
Metals

Rod Swivel 15° (0.8π)


2 Holes 7⁄16" (11.1) Dia. All Directions

Clamp P2676 provides a means of rod suspension where a free swing


of up to 15° (0.8π) is required. Clamp will accommodate 1⁄4" (6.4),
PrimeAngle

3
⁄8" (9.5), or 1⁄2" (12.7) rods. Order swivel nuts P2679-4,-6, or -8 as
System

required. Clamp may also be used with P2677 as illustrated in


application drawings on page 126.
Clamp Materials: 1⁄8" (3.2) thick steel.
Product
Index

Note
When used for mechanical supports, load capacities of brackets and fittings should be in compliance with the American Standard Code for Pressure Piping.

124 General Fittings


Beam Clamps

P2898 Universal Beam Clamp

Channel
15⁄8"
FM

Telestrut
System
G

Hardware
Nuts &
D • Maximum temperature of 450˚ F (232° C)
• At least one full thread must be exposed
C F
A B C D E F G Max Load Wt/100 pcs
in In (mm) In (mm) In (mm) In (mm) In (mm) In (mm) Lbs (kg) Lbs (kg)
3
P2898-37 ⁄8 1 11⁄2 1
⁄2 1 3
⁄4 7
⁄8 400 33

General
Fittings
25.4 38.1 12.7 25.4 19.1 22.2 181.8 15.0
1
P2898-50 ⁄2 1 11⁄2 1
⁄2 1 3
⁄4 7
⁄8 500 33
25.4 38.1 12.7 25.4 19.1 22.2 227.3 15.0
5
P2898-62 ⁄8 11⁄2 11⁄2 1
⁄2 1 3
⁄4 1 600 22

Pipe/Conduit
A 38.1 38.1 12.7 25.4 19.1 25.4 272.7 10.0

Supports
3
P2898-75 ⁄4 17⁄8 13⁄4 5
⁄8 13⁄8 1 11⁄4 800 88
E
47.6 44.5 15.9 34.9 25.4 31.8 363.6 40.0
B P2898-87 7
⁄8 2 13⁄4 5
⁄8 11⁄2 1 11⁄4 1,200 79
50.8 44.5 15.9 38.1 25.4 31.8 545.5 35.9

Electrical
Fittings
Concrete
Inserts
P2899 WIDE THROAT TOP BEAM CLAMP

11⁄4" Framing
FM

System
E

3⁄4"
(19.1) 11⁄4"

Framing
C (31.8)

System
13⁄16"
Fiberglass
A • Maximum temperature of 450˚ F (232° C)

System
D Rod Size Max.
A B C D E Load Wt/100 pcs
B in In (mm) In (mm) In (mm) In (mm) Lbs (kg) Lbs (kg)
P2899-37 3⁄8 15⁄8 2 1 7
8 400 28
Special
Metals

41.3 50.8 25.4 22.2 184.4 12.7


P2899-50 1⁄2 15⁄8 2 1 7
8 500 34
41.3 50.8 25.4 22.2 227.3 15.4
P2899-62 5⁄8 13⁄4 21⁄4 11⁄4 1 600 66
PrimeAngle

44.5 57.2 31.8 25.4 272.7 30.0


System

P2899-75 3⁄4 17⁄8 23⁄8 13⁄8 11⁄4 800 83


47.6 60.3 34.9 31.8 363.6 37.7
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: 9⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)

General Fittings 125


® Beam Clamps

P2682 Wt/100 pcs: 55 Lbs (24.9 kg) P2677 Wt/100 pcs: 30 Lbs (13.6 kg)
Channel
15⁄8"

1 5⁄ 8"
(41.3) 3
⁄8" X 2"
Telestrut
System

3 3 25⁄32" Screw, Nut,


⁄16" (96.0)
(4.8) and Lock Washer
1
2 1⁄2" Included
⁄2" (63.5) P2676
(12.7) 1 3⁄8" (34.9)
Hardware

3
1 ⁄4"
Nuts &

1
(44.5) ⁄8" (3.2) Thick
4 Holes 1 1⁄4"
Rod Size 7
⁄16" (11.1) Dia. (31.8)
up to 1⁄2"
General
Fittings

Rod Size
P2682 up to 1⁄2"
Pipe/Conduit
Supports

P2677
Rod Size Rod Swivel 15° (0.08π)
up to 1⁄2" All Directions
Clevis hanger to be used with
Electrical

P2676 or P2682 to provide angle


Fittings

Hanger clevis for up to 1⁄2" (12.7) Rod Swivel 15° (0.08π)


rod suspension from wood ceilings. All Directions adjustment and 15° (0.08 π) free
Design Load
May also be used with P2677 as swing for up to 1⁄2" (12.7) rod
500 Lbs (226.8 kg)
illustrated in application drawings. suspension. Order swivel nuts
P2679-4, -6, or -8 as required.
Concrete
Inserts

P2674 Wt/100 pcs: 17 Lbs (7.7 kg) P2679-4, -6 & -8 SWIVEL NUT
11⁄4" Framing
System

1
⁄4" X 1 1⁄2"
Screw, Nut,
and Lock Washer
1 3⁄4" Included
(44.5) 7
⁄8" (22.2)
⁄16" Framing
System

1
⁄8" (3.2) Thick

13 32
Hole ⁄ " (10.3) Dia.
13

13⁄16"
(20.6) P2675
Fiberglass
System

• Use with P2676 and P2677.


Special
Metals

• Order size as required.

Part Thread Wt/100 pcs


Rod Size Number Size Lbs (kg)
up to 3⁄8" P2679-4 1
⁄4"-20 4
PrimeAngle

1.8
System

3
P2679-6 ⁄8"-16 5
2.3
Design Load 1
Clevis hanger to be used with P2675 P2679-8 ⁄2"-13 6
250 Lbs (113.4 kg)
to provide angle adjustment for up to 2.7
Product

3
⁄8" rod suspension as illustrated.
Index

126 General Fittings


Beam Clamps

P1648S thru P1653S

Channel
Design

15⁄8"
Set Screw Part “A” “B” “C” “D” Wt/100 pcs Load
Size C Number In In (mm) In In (mm) Lbs (kg) Lbs (kg)
1 1 3
Weld Included P1648S ⁄4 -20 ⁄8 ⁄8 x 11⁄2 7
⁄8 67 650

Telestrut
3.2 22.2 30.4 294.8

System
5 1 3
P1649S ⁄16 -18 ⁄8 ⁄8 x 11⁄2 7
⁄8 67 650
3.2 22.2 30.4 294.8
7
⁄8" B P1649AS 3
⁄8 -16 1
⁄8 3
⁄8 x 11⁄2 7
⁄8 67 650
(22.2) 3.2 22.2 30.4 294.8

Hardware
2 1⁄2" P1650S 3
⁄8 -16 3
⁄16 1
⁄2 x 11⁄2 15
⁄16 100 1,100

Nuts &
(63.5) 4.8 23.8 45.4 499.0
1 3 1
Tapped Hole P1650AS ⁄2 -13 ⁄16 ⁄2 x 11⁄2 15
⁄16 100 1,100
Size A 4.8 23.8 45.4 499.0
1 1 1
P1651S ⁄2 -13 ⁄4 ⁄2 x 11⁄2 15
⁄16 130 1,600

General
Fittings
2 1⁄2" 6.4 23.8 59.0 725.7
(63.5) P1651AS 5
⁄8 -11 1
⁄4 1
⁄2 x 11⁄2 15
⁄16 130 1,600
D 6.4 23.8 59.0 725.7
5 5 5
P1652S ⁄8 -11 ⁄16 ⁄8 x 11⁄2 15⁄16 160 2,400

Pipe/Conduit
7.9 33.3 72.6 1,088.6

Supports
3 5 5
P1653S ⁄4 -10 ⁄16 ⁄8 x 11⁄2 15⁄16 160 2,400
7.9 33.3 72.6 1,088.6

For beams under 7⁄8" (22.2) thick flange.

Electrical
Fittings
Weld is not continuous it is either 11⁄4"
(31.8) - 13⁄4" (44.5) long or 2 spot welds.
All welds are on the top and bottom.

Concrete
Inserts
P2398S, P2401S, P2403S
Design

11⁄4" Framing
Part “A” “B” “C” “D” “E” Wt/100 pcs Load

System
Number In In (mm) In In (mm) In (mm) Lbs (kg) Lbs (kg)
1 1 3
P2398S ⁄4 -20 ⁄8 ⁄8 x 2 121⁄32 7
⁄8 109 800
3.2 42.1 22.2 49.4 362.9
3 3 1
P2401S ⁄8 -16 ⁄16 ⁄2 x 2 111⁄16 29
⁄32 156 1,300
Set Screw 4.8 42.9 23.0 70.8 589.7

Framing
Weld Size C Included P2403S 1
⁄2 -13 1
⁄4 1
⁄2 x 2 111⁄16 15
⁄16 201 1,900

System
6.4 42.9 23.8 91.2 861.8
5 5 5
P2405S ⁄8 -11 ⁄16 ⁄8 x 2 111⁄16 15⁄16 311 2,400

13⁄16"
7.9 42.9 33.3 141.1 1,088.6

For beams between 3⁄4" (19.1) to 15⁄8" (41.3) thick flanges.


D

Fiberglass
3 5⁄8"

System
(92.1)

B
Tapped Hole
Size A
Special
Metals

3 1⁄4"
(82.6)
E
PrimeAngle
System

Weld is not continuous it is either 11⁄4"


(31.8) - 13⁄4" (44.5) long or 2 spot welds.
All welds are on the top and bottom.
Product
Index

General Fittings 127


® Beam Clamps

P1654A thru P1661A Retainer Strap


Channel
15⁄8"

Strap Flange Beam


Part Width “A” Wt/100 pcs Clamp
Number In (mm) In (mm) Lbs (kg) Used With
Telestrut
System

P1654 A 6 7 25 P2675
For beams under 152.4 177.8 11.3
7
⁄8" (22.2) thick P1655 A 9 10 34 P2675
flange. 228.6 254.0 15.4
P1656 A 6 9 35 P1648 S Thru
Hardware
Nuts &

152.4 228.6 15.9


P1657 A 9 12 47 P1651 AS, and
228.6 304.8 21.3
P1658 A 12 15 59 P2398 S Series
304.8 381.0 26.8
General
Fittings

P1659 A 6 9 33 P2676
152.4 228.6 15.0
P1654 A & P1655 A
7
P1660 A 9 12 45 P2676
12 Gage ⁄16" (11.1) Hole 228.6 304.8 20.4
Pipe/Conduit

7
⁄ 8" P1661 A 12 15 57 P2676
Supports

(22.2) 304.8 381.0 25.9


A

1"
(25.4)
Electrical
Fittings

17⁄32" (13.5) Hole

A 1
⁄ 2"
Concrete
Inserts

(12.7)
P1656 A thru P1661 A 1 3 ⁄8 "
(34.9)
11⁄4" Framing

P1271S Wt/100 pcs: 95 Lbs (43.1 kg) P1796S Wt/100 pcs: 91 Lbs (41.3 kg)
System

1⁄2" - 13 X 11⁄2" 1
⁄2" - 13 X 11⁄2"
Set Screw Included Set Screw Included
⁄16" Framing
System

7
7 ⁄8"
⁄8" (22.2)
(22.2)
13

1 3⁄4"
(44.5)
Fiberglass
System

3 1⁄2"
5 (88.9)
1 ⁄8"
(41.3)
Special
Metals

3
⁄8"
(9.5) 1 1⁄2" 3 1⁄2"
(38.1)
PrimeAngle

9
2 Holes ⁄16" (14.3) Dia.
1
⁄4" (88.9)
System

Design Load Each (6.4) Design Load Each


Note: Requires P1010 Channel Nut 500 Lbs (226.8 kg) 500 Lbs (226.8 kg)
and bolt. Use in Pairs Only Use in Pairs Only
Product
Index

Note
When used for mechanical supports, load capacities of brackets and fittings should be in compliance with the American Standard Code for Pressure Piping.

128 General Fittings


Beam Clamps

Wt/100 pcs: 83 Lbs (37.6 kg)


P2824-6,-9,-12 P2785

Channel
15⁄8"
3
⁄16" 3
⁄8" Hex Nuts and

Telestrut
System
(4.8) "U" Bolt Included

1
⁄4" 7
⁄8"

Hardware
(6.4)

Nuts &
(22.2)

3
⁄16"
(4.8) 3"

General
Fittings
3
(76.2)
3 ⁄8"
A (85.7)

Clamp Requires

Pipe/Conduit
1
⁄2" Diameter Rod and

Supports
2 Hex Nuts (Sold Seperately) Design Load Each
Design 1000 Lbs (453.6 kg)
Part “A” Wt/100 pcs Load Use in Pairs Only
Number In (mm) Lbs (kg) Lbs (kg)

Electrical
P2824-6 21⁄2 - 6 125 500

Fittings
63.5 - 152.4 56.7 226.8
P2824-9 51⁄2 - 9 140 500
• For use with Beams up to 3⁄4" (19.1) Flanges and with
139.7 - 228.6 63.5 226.8
Channels P1000, P1100, P2000, P3000, P3300, P3301,
P2824-12 81⁄2 - 12 171 500 P4000, P4001, P4100, and P4101.

Concrete
215.9 - 304.8 77.6 226.8

Inserts
P2786 Wt/100 pcs: 92 Lbs (41.7 kg) P2787 Wt/100 pcs: 112 Lbs (50.8 kg)

11⁄4" Framing
System
3
⁄8" Hex Nuts and
"U" Bolt Included
3
⁄8" Hex Nuts and
"U" Bolt Included 1
⁄4" 7
⁄8 "
(6.4)

Framing
1
(22.2)
⁄4" 7

System
(6.4) ⁄8 "
(22.2)

13⁄16"
3"
(76.2)
3"

Fiberglass
(76.2)

System
81⁄4"
(209.6)
5"
(127)
Special
Metals

Design Load Each Design Load Each


1000 Lbs (453.6 kg) 1000 Lbs (453.6 kg)
PrimeAngle
System

Use in Pairs Only Use in Pairs Only

• For use with Beams up to 3⁄4" (19.1) Flanges and with • For use with Beams up to 3⁄4" (19.1) Flanges and with
Channels P1001, P1101, P2001, P3001, P5000, and P5500. Channels P5001 and P5501.
Product
Index

Note
When used for mechanical supports, load capacities of brackets and fittings should be in compliance with the American Standard Code for Pressure Piping.

General Fittings 129


® Beam Clamps

P2867 P2867A
Channel
15⁄8"

A
A
Telestrut
System

5"
Hardware
Nuts &

3
3 ⁄8" (127.0)
(85.7)
1
⁄4" (6.4)
Thick
General
Fittings

3" Part Beam Wt/100 pcs 3" Part Beam Wt/100 pcs
(76.2) (76.2)
Pipe/Conduit

Number Size "A" Lbs (kg) Number Size "A" Lbs (kg)
Supports

P2867 4"-6" 142 P2867A 4"-6" 151


64.4 68.5
P2867-9 6"-9" 151 P2867A-9 6"-9" 157
• Includes: "J" Bolt, "U" Bolt and 68.5 • Includes: "J" Bolt, "U" Bolt and 71.2
Hex Nuts. P2867-12 9"-12" 160 Hex Nuts. P2867A-12 9"-12" 166
Electrical

• For use with Channels P1000, 72.6 • For use with Channel P1001, 75.3
Fittings

P1100, P2000, P3000, P3300, P2867-15 12"-15" 170 P1101, P2001, P3001, P5000, P2867A-15 12"-15" 176
P3301, P4000, P4001, P4100, 77.1 and P5500. 79.8
and P4101. P2867A-18 15"-18" 185
P2867-18 15"-18" 179
81.2 83.9
Concrete
Inserts

P2867B P2868
A
11⁄4" Framing

A
System
⁄16" Framing

3 3⁄8"
System

81⁄4"
(85.7)
(209.6) 1
⁄4" (6.4)
Thick
13

1
Fiberglass

⁄4" (6.4)
System

Thick
3"
(76.2)
Special
Metals

3" Part Beam Wt/100 pcs Part Beam Wt/100 pcs


(76.2) Number Size "A" Lbs (kg)
• Includes: Center Rod, "U" Bolts and Number Size "A" Lbs (kg)
P2867B 4"-6" 161 Hex Nuts. P2868 4"-6" 282
73.0 127.9
• For use with Channels P1000, P1100,
PrimeAngle

• Includes: "J" Bolt, "U" Bolt and P2867B-9 6"-9" 167


System

P2000, P3000, P3300, P3301, P2868-9 6"-9" 289


Hex Nuts. 75.7 P4000, P4001, P4100, and P4101. 131.1
• For use with Channel P5001, P2867B-12 9"-12" 176 P2868-12 9"-12" 296
and P5501. 79.8 134.3
P2867B-15 12"-15" 186 P2868-15 12"-15" 304
84.4 137.9
Product
Index

P2867B-18 15"-18" 195 P2868-18 15"-18" 311


88.5 141.1

130 General Fittings


Beam Clamps

P2868A P2868B

Channel
15⁄8"
A

Telestrut
System
81⁄4"

Hardware
Nuts &
(209.6)
5"
(127.0)
1
⁄4" (6.4)

General
Fittings
Thick 1
⁄4" (6.4)
Thick

Pipe/Conduit
3"

Supports
(76.2)
3"
(76.2)

Part Beam Wt/100 pcs Part Beam Wt/100 pcs


Number Size "A" Lbs (kg) Number Size "A" Lbs (kg)

Electrical
Fittings
• Includes: Center Rod, "U" Bolts and • Includes: Center Rod, "U" Bolts and
P2868A 4"-6" 300 P2868B 4"-6" 320
Hex Nuts. 136.1 Hex Nuts. 145.1
• For use with Channels P1001, • For use with Channels P5001, and
P2868A-9 6"-9" 307 P2868B-9 6"-9" 327
P1101, P2001, P3001, P5000, and 139.3 P5501. 148.3
P5500.

Concrete
P2868A-12 9"-12" 314 P2868B-12 9"-12" 334

Inserts
142.2 151.5
P2868A-15 12"-15" 322 P2868B-15 12"-15" 342
146.1 155.1
P2868A-18 15"-18" 329 P2868B-18 15"-18" 349

11⁄4" Framing
149.2 153.3

System
P2893 Wt/100 pcs: 14 lbs. (6.4 kg) P2894

Framing
System
13⁄16"
B

Fiberglass
System
A Material: Malleable Iron
7
⁄8" Maximum Flange Thickness
Note: Tapped Hole on Top and Bottom
Special
Metals

Rod Load
Part Size “A” “B” Ratings Wt/100 pcs
Number In In (mm) In (mm) Lbs (kg) Lbs (kg)
1
P2894-25 ⁄4 11⁄8 11⁄4 150 23
PrimeAngle

28.6 31.8 68.0 10.4


System

3
P2894-37 ⁄8 2 2 350 95
Material: Steel 50.8 50.8 158.8 43.1
Use With: 1⁄4" rod P2894-50 1
⁄2 25⁄8 21⁄2 400 195
Load Rating: 75 lbs. 66.7 63.5 181.4 88.5
Product
Index

Note
When used for mechanical supports, load capacities of brackets and fittings should be in compliance with the American Standard Code for Pressure Piping.

General Fittings 131


® Beam Clamps

P2895 P2896
Channel
15⁄8"

3
⁄ 8"
Telestrut
System

3⁄4" B
(9.5)
(19.1)
2 1⁄4"
(57.2) B
3
⁄4"
Hardware
Nuts &

(19.1)

A A
1
⁄2 "
General
Fittings

(12.7)

Rod Load Rod Load


Part Size “A” “B” Ratings Wt/100 pcs Part Size “A” “B” Ratings Wt/100 pcs
Pipe/Conduit

Number In In (mm) In (mm) Lbs (kg) Lbs (kg) Number In In (mm) In (mm) Lbs (kg) Lbs (kg)
Supports

3
P2895-37 ⁄8 25⁄16 3
⁄8 330 35 P2896-37 3
⁄8 111⁄16 13⁄4 400 38
58.7 9.5 149.7 15.9 42.9 44.5 181.4 17.2
1
P2895-50 ⁄2 21⁄4 1
⁄2 380 41 P2896-50 1
⁄2 123⁄32 13⁄4 400 52
57.2 12.7 172.4 18.6 43.7 44.5 181.4 23.6
5
P2895-62 ⁄8 23⁄8 5
⁄8 450 67 P2896-62 5
⁄8 115⁄16 2 450 68
Electrical
Fittings

60.3 15.9 204.1 30.4 49.2 50.8 204.1 30.8


3
P2895-75 ⁄4 21⁄4 1
⁄2 500 72 P2896-75 3
⁄4 21⁄32 2 600 128
57.2 12.7 226.8 32.7 51.6 50.8 272.2 58.1

Material: Steel Material: Malleable Iron, Steel Set Screw


Concrete
Inserts

P1386 Wt/100 pcs: 27 Lbs (12.2 kg) P1379S Wt/100 pcs: 75 Lbs (34.0kg)
11⁄4" Framing

Clamp Requires
System

1
1 ⁄2" - 13 X 11⁄2"
⁄2" - 13 X 11⁄2" Set Screw Included
Hex Head Cap Screw
1
⁄2" and 1⁄2" Channel
Clamp Requires
(12.7) Nut Not Included.
1" 1
⁄2" x 13⁄16"
⁄16" Framing

(25.4) Hex Head Cap Screw


System

and 1⁄2" Channel


Nut Not Included.
13

1 7⁄8"
Fiberglass

3
(47.6) ⁄8"
System

1
⁄4" (9.5)
(6.4)
3 1⁄4"
(82.6)
Special
Metals

Design
Load Each Design
Channel (Use in Pairs Only) Load Each
Style Lbs (kg) Channel (Use in Pairs Only)
Style Lbs (kg)
PrimeAngle

P1000 600
System

272.2 P1000 600


P1100 500 272.2
226.8 P1100 500
P2000 450 226.8
204.1 P2000 450
Product

217.7
Index

132 General Fittings


Beam Clamps

P1272S, P1985S, P1986S

Channel
15⁄8"
Telestrut
System
Hardware
Nuts &
D
A Design Load
Flange “D” Set Per Pair
Part “A” Thickness Screw Wt/100 pcs (Use in Pairs Only)

General
Fittings
Number In (mm) In (mm) Included Lbs (kg) Lbs (kg)
1
P1272S ⁄4 Up to 3⁄4 3
⁄8-16 x 11⁄2 39 450
1
1 ⁄4 " 6.4 Up to 19.1 17.7 204.1
3
(31.8) P1985S ⁄8 Up to 3⁄4 1
⁄2-13 x 11⁄2 62 1,000
9.5 Up to 19.1 28.1 453.6

Pipe/Conduit
Supports
3 7 1
P1986S ⁄8 ⁄8 to 2 ⁄2-13 x 11⁄2 74 900
9.5 22.2 - 50.8 33.6 408.2

P3087 Column Insert P3088 Column Insert


Wt/100 pcs: 136 Lbs (61.7 kg) Wt/100 pcs: 120 Lbs (54.4 kg)

Electrical
Fittings
Concrete
Inserts
11⁄4" Framing
P3088A

System
P3087A
P3088B
P3087B

Framing
Channel

System
Channel

13⁄16"
Adjusting Screws
Adjusting Screws Included
Included

Fiberglass
System
• Adjusting Screws Included. • Adjusting Screws Included.
• Unistrut channel not included. • Unistrut channel not included.
• Part number P3087 consists of: (1) piece P3087A, (1) piece P3087B and • Part number P3088 consists of: (1) piece P3088A, (1) piece P3088B and
Special
Metals

(2) set screws (2) set screws

Channel Design Pull Design Channel Design Pull Design


Part Out Load Slip Load Part Out Load Slip Load
A Number Lbs (kg) Lbs (kg) A Number Lbs (kg) Lbs (kg)
PrimeAngle
System

P1000 1,000 800 P3300 1,000 800


453.6 362.9 453.6 362.9
P1100 700 500 P4100 700 500
317.5 226.8 317.5 226.8
P2000 500 300 A - 1" P4000 500 300
A - 1"
Product

226.8 136.1 (A - 25.4) 226.8 136.1


Index

(A - 25.4)
Safety factor of 3. Safety factor of 3.

General Fittings 133


® Beam Clamps

PLLC025 Flange Clamp


Channel
15⁄8"

Cup point set screw


and lock nut included.
Telestrut
System
Hardware

40 Lbs.
Nuts &

Set Screw Torque = 3 Ft-Lb


Lock Nut Torque = 3.5 Ft-Lb
General
Fittings

X, Y are threaded holes.


“Z” Set
Part Rod Screw Wt/100 pcs
Pipe/Conduit

Number Size Size Lbs (kg)


Supports

Z PLLC025 1
⁄ 4" 1
⁄ 4" 16
135 Lbs. 7.3

X T Material: Malleable Iron.


U
Electrical
Fittings

W Dimensions
V Part “S” “T” “U” “V”,“W” “X”,“Y”
Number In (mm) In (mm) In (mm) In (mm) In
5
Y PLLC025 ⁄8 1 17⁄16 3
⁄4 1
⁄4 X 20
S 15.9 25.4 36.5 19.1
Concrete
Inserts

PFL037 thru PFL050T Flange Clamp


(When used for sprinkler
11⁄4" Framing

FM
systems only.)
System

Cup point set screw Set Screw Torque = 6 Ft-Lb


and lock nut included. Lock Nut Torque = 16 Ft-Lb

Safety Factor: 5
⁄16" Framing

“Z” Set Max. Allowable


System

Part Type of Rod Screw Wt/100 pcs Load


Number Hole Size Size Lbs (kg) Lbs (kg)
3 3
PFL037 Clear ⁄8" ⁄8" 28 540
13

12.7 244.9
3 3
PFL037T Tapped ⁄8" ⁄8" 28 540
Fiberglass

12.7 244.9
System

1 3
PFL050 Clear ⁄2" ⁄8" 40 700
18.1 317.5
1 3
PFL050T Tapped ⁄2" ⁄8" 40 700
18.1 317.5
Special
Metals

Material: Malleable Iron.


Z
Dimensions
Part “T” “U” “V” “W” “X” “Y”
Number In (mm) In (mm) In (mm) In(mm) In (mm) In (mm)
PrimeAngle
System

T PFL037 111⁄16 19⁄16 7


⁄8 3
⁄4 1 7
⁄16
42.9 39.7 22.2 19.1 25.4 11.1
U V PFL037T 111⁄16 19⁄16 7
⁄8 3
⁄4 1 3
⁄8 Tapped Hole
W 42.9 39.7 22.2 19.1 25.4
PFL050 2 123⁄32 1 29
⁄32 13⁄32 9
⁄16
Product

50.8 43.7 25.4 23.0 27.8 14.3


Index

X Y PFL050T 2 123⁄32 1 29
⁄32 13⁄32 1
⁄2 Tapped Hole
50.8 43.7 25.4 23.0 27.8

134 General Fittings


Beam Clamps

PLF3037 thru PLF3075 Flange Clamp

Channel
15⁄8"
Threaded Rod & Nut
Not Included
FM (When used for
sprinkler systems only.)

Telestrut
System
Safety Factor: 4
Max.
Allowable
Part Rod Wt/100 pcs Load Torque
Number Size Lbs (kg) Lbs (kg) Ft-Lbs

Hardware
Nuts &
3
PLF3037 ⁄8" 53 270 15
24.0 122.5
1
PLF3050 ⁄2" 91 450 29
41.3 204.1
5

General
PLF3062 ⁄8" 186 900 69

Fittings
84.4 408.2
3
PLF3075 ⁄4" 334 1,350 130
151.5 612.3
Material: Malleable Iron
Z

Pipe/Conduit
Dimensions

Supports
Part “X” “W” “V” “T“ “R” “S”
Number In (mm) In (mm) In (mm) In (mm) In (mm) In (mm)
V
PLF3037 1 0 - 13⁄16 3
⁄8 9
⁄32 11⁄2 7
⁄8
25.4 0 - 30.2 9.5 7.1 38.1 22.2
W R S PLF3050 13⁄8 0 - 19⁄16 1
⁄2 11
⁄32 115⁄16 15⁄32

Electrical
34.9 0 - 39.7 12.7 8.7 49.2 29.4

Fittings
X
PLF3062 113⁄16 0 - 23⁄16 5
⁄8 1
⁄2 211⁄32 17⁄16
V T 46.0 0 - 55.6 15.9 12.7 59.5 36.5
PLF3075 23⁄16 0 - 13⁄4 3
⁄4 5
⁄8 3 13⁄4
55.6 0 - 44.5 19.1 15.9 76.2 44.5

Concrete
Inserts
PLF9037 thru PLF9100 Flange Clamp

11⁄4" Framing
Threaded Rod & Nut Safety Factor: 5

System
Not Included
Max.
Allowable
Part Rod Wt/100 pcs Load Torque
Number Size Lbs (kg) Lbs (kg) Ft-Lbs
3
PLF9037 ⁄8" 55 440 15

Framing
24.9 199.6

System
1
PLF9050 ⁄2" 122 630 29
55.3 285.8

13⁄16"
5
PLF9062 ⁄8" 200 1,260 69
90.7 571.5
3
PLF9075 ⁄4" 367 1,880 131

Fiberglass
166.5 852.8

System
PLF9100 1" 1,101 3,150 173
499.4 1428.8

Material: Malleable Iron


Special

Dimensions
Metals

Part “X” “W” “V” “T” “S”


Z T Number In (mm) In (mm) In (mm) In (mm) In (mm)
3
PLF9037 1 ⁄4 - 111⁄16 1
⁄2 3
⁄4 1
25.4 19.1 - 42.9 12.7 19.1 25.4
PrimeAngle

V
PLF9050 13⁄8 1 - 23⁄8 21
⁄32 15
⁄16 13⁄16
System

S 34.9 25.4 - 60.3 16.7 23.8 30.2


W PLF9062 111⁄16 11⁄8 - 23⁄4 13
⁄16 11⁄8 13⁄8
X 42.9 28.6 - 69.9 20.6 28.6 34.9
PLF9075 2 11⁄4 - 31⁄4 1 13⁄8 13⁄4
V
50.8 31.8 - 182.6 25.4 34.9 44.5
Product
Index

PLF9100 3 13⁄4 - 33⁄4 11⁄2 23⁄16 21⁄2


76.2 44.5 - 95.3 38.1 55.6 63.5

General Fittings 135


® Trolley Assemblies

P2749*, P2749N†
Channel
15⁄8"

1 1⁄4" 1 3⁄16"
(31.8) (30.2)
Telestrut
System

1 21⁄32"
(42.1)
9 9
⁄32" (7.1) Dia. Hole 3
⁄16" ⁄32"
7
⁄16" (4.8) (7.1)
Hardware

(11.1)
Nuts &

3
⁄4 " Design
(19.1) 1 1⁄4" Part Load Wt/100 pcs
(31.8)
Number Lbs (kg) Lbs (kg)
General
Fittings

P2749 50 21
22.7 9.5
Clevis Material: 12 gauge.
P2749N 10 13
*Wheel bearings are stainless steel, and should not be lubricated. 4.5 5.9
Pipe/Conduit

† "N" indicates acetal wheels.


Supports

P2750*, P2750N†
1 1 ⁄ 4"
(31.8)
Electrical

1 3⁄16"
Fittings

9
⁄32" (7.1) Dia. Hole 1 23⁄32" (30.2)
(43.7)
9
9 ⁄32"
⁄16"x 9⁄32" (14.3 x 7.1) Slots (7.1)
1
⁄ 4" 7
Concrete

⁄16"
Inserts

(6.4) (11.1)
1"
(25.4) 1" Design
1" (25.4) Part Load Wt/100 pcs
11⁄4" Framing

(25.4) Number Lbs (kg) Lbs (kg)


System

1
3 ⁄8"
(79.4) P2750 100 55
45.4 24.9
Clevis Material: 12 gauge. P2750N 20 32
*Wheel bearings are stainless steel, and should not be lubricated. 9.1 14.5
† "N" indicates acetal wheels.
⁄16" Framing
System

P2751*, P2751 N†
1 1⁄4"
(31.8)
13

1 15⁄32" 23
(37.3) 1 ⁄32"
(43.7)
Fiberglass
System

4 23⁄32"
(105.6)
1
⁄4 "
(6.4) 2 7⁄16"
(61.9)
Special
Metals

3
1" ⁄4" (19.1) Dia.
(25.4) 1" 1
⁄4" (6.4)
(25.4)
1"
PrimeAngle

(25.4)
System

Design
3 1⁄8"
(79.4) Part Load Wt/100 pcs
Number Lbs (kg) Lbs (kg)
P2751 100 63
45.4 28.6
Product

Clevis Material: 12 gauge.


Index

P2751N 20 40
*Wheel bearings are stainless steel, and should not be lubricated. 9.1 18.1
† "N" indicates acetal wheels.

136 General Fittings


Trolley Assemblies

P2949 Wt/100 pcs: 46 Lbs (20.9 kg)

Channel
15⁄8"
1 5⁄16"
(33.3) 1 3⁄16"
(30.2)

Telestrut
System
Design Load
In P1000
FPM RPM Lbs (kg)
3 13⁄32" 180 600 150
(86.5)

Hardware
9
⁄32" 68.0

Nuts &
Hole 15
9
(7.1) 1 ⁄16" 90 300 225
⁄16" (14.3) Dia. (49.2)
102.1
13 30 100 437
⁄16" 1
⁄4"
(20.6) 198.2
(6.4)

General
Fittings
5
⁄8"
(15.9)
5
Wheel bearings are stainless steel.
⁄8" Do not lubricate.
(15.9) 1 1⁄4"

Pipe/Conduit
(31.8)

Supports
P2950 Wt/100 pcs: 110 Lbs (49.9 kg)

1 5⁄16"

Electrical
Fittings
(33.3) 1 3⁄16"
(30.2) Design Load
In P1000
FPM RPM Lbs (kg)
180 600 300

Concrete
Inserts
3 Holes 3 13⁄32" 136.1
9
⁄16" (14.3) Dia. (86.5) 9 90 300 450
⁄32"15
(7.1) 1 ⁄16" 204.1
(49.2) 30 100 600
272.2

11⁄4" Framing
13
⁄16" 1
⁄4"

System
13
⁄16" (20.6)
(20.6) (6.4)

Wheel bearings are stainless steel.


15
⁄16" Do not lubricate.
13 15
⁄16" (23.8)
⁄16"
(20.6) (23.8)

Framing
1
3 ⁄2"
(88.9)

System
13⁄16"
P1834 Channel Trolley Support P1834A Channel Trolley Support
Wt/100 pcs: 102 Lbs (46.3 kg) Wt/100 pcs: 220 Lbs (99.8 kg)

Fiberglass
System
1 Hole 1 Hole
9
9
⁄16" (14.3) Dia. 3 1⁄2" ⁄16" (14.3) Dia.
5
1 ⁄8" (88.9)
(41.3)

3 3⁄4"
Special
Metals

3 3⁄4"
(95.3) (95.3)
PrimeAngle
System

2 Holes 2 Holes
7
7
⁄16" (11.1) Dia. ⁄16" (11.1) Dia.

1" 1"
(25.4) (25.4)
3 1 3 1
Requires ⁄8" x 2 ⁄2" Bolt Requires ⁄8" x 2 ⁄2" Bolt
Product

Design Load Design Load


Index

and 3⁄8" Nut 1200 Lbs (544.3 kg) and 3⁄8" Nut 2500 Lbs (1,134.0 kg)
(not included) (not included)

General Fittings 137


® Special Application Fittings

P1843 Adjustable Hinge Connection P1354 Adjustable Hinge Connection


Channel
15⁄8"

Wt/100 pcs: 68 Lbs (30.8 kg) Wt/100 pcs: 109 Lbs (49.4 kg)
Telestrut
System

2 1⁄8"
(54.0) 4"
Hardware

(101.6)
Nuts &

2 1⁄8"
(54.0)
4"
(101.6)
General
Fittings
Pipe/Conduit
Supports

P1354A Adjustable Hinge Connection P1201, P1202, P1203 Ladder Rung


Wt/100 pcs: 109 Lbs (49.4 kg)
Electrical
Fittings

1 5 ⁄8 "
(41.3)

13
⁄16"
(20.6)
Concrete
Inserts

A
2 1⁄8"
(54.0)
13
⁄16" Part “A” Wt/100 pcs
(20.6) Number In (mm) Lbs (kg)
4"
11⁄4" Framing

(101.6) P1201 12 186


System

304.8 84.4
P1202 15 221
381.0 100.2
P1203 18 254
457.2 115.2
⁄16" Framing
System

P2354 R-L, P2355 R-L Reel Rack Supports for 11⁄4" and 2" Pipe
Std.
13

Part “A” Pipe Size Wt/100 pcs


Number In (mm) In (mm) Lbs (kg)
A A
Fiberglass

P2354 R-L 3 11⁄4 220


System

76.2 31.8 99.8


P2355 R-L 35⁄8 2 252
92.1 50.8 114.3
Special
Metals

5 3⁄8" 5 3⁄8" Vertical Max.


(136.5) (136.5) Channel Allowable Load
Part No. Gauge Lbs (kg)
P1000 12 3,000
PrimeAngle

1360.8
System

P1100 14 2,000
907.2
Left Hand Right Hand
P2000 16 2,000
907.2
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)
9

138 General Fittings


Special Application Fittings

P1204 thru P1208 Wall Ladder Bracket

Channel
15⁄8"
A 13
⁄16" Part “A” “B” Wt/100 pcs
Number In (mm) In (mm) Lbs (kg)

Telestrut
(20.6)

System
P1204 23⁄8 6 113
60.3 152.4 51.3
P1205 43⁄8 8 164
111.1 203.2 74.4

Hardware
63⁄8

Nuts &
P1206 10 216
2" B 161.9 254.0 98.0
(50.8) P1207 83⁄8 12 267
212.7 304.8 121.1
P1208 103⁄8 14 318

General
Fittings
263.5 355.6 144.2

13
⁄16"
(20.6)

Pipe/Conduit
Supports
P1944 45° (.25π) Stair Tread Support P2655 371⁄2° (.21π) Stair Tread Support
Wt/100 pcs: 220 Lbs (99.8 kg) Wt/100 pcs: 213 Lbs (96.6 kg)

Electrical
Fittings
1 1⁄16" 1 1⁄16"
8 7⁄8" (27.0) 45° 8 7⁄8" (27.0) 37 1⁄2°
(225.4) 3 1⁄2" (0.25π) (225.4) 3 1⁄2"
1 (88.9) (88.9) (0.21π)
3 ⁄2" 3 1⁄2"
(88.9) (88.9)

Concrete
13
⁄16" 1 7⁄8" 13
⁄16"

Inserts
1 7⁄8"
(20.6) (47.6) (20.6) (47.6)

3 3⁄4" 3 3⁄4"
(95.3) (95.3)

11⁄4" Framing
System
Framing
System
P2470-50, -75, -100 Pipe Coupling Fitting P2454 Double Pipe Axle Support
Wt/100 pcs: 310 Lbs (140.6 kg)

13⁄16"
3"
(76.2)

Fiberglass
System
5 3⁄8"
(136.5) Special
Metals

Pipe Coupling
Part Size Wt/100 pcs
75⁄8"
Number In Lbs (kg) (193.7)
1
P2470-50 ⁄2 77
34.9
PrimeAngle

3"
System

3
P2470-75 ⁄4 93
(76.2)
42.2
P2470-100 1 103 Load Rating 4,000 Lbs (1,814 kg)
46.7 1
For 1 ⁄4" (31.8) Standard Pipe
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: 9⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness: 1⁄4" (6.4mm)

General Fittings 139


® Seismic Retrofit Fittings

SPF® 100 Seismic Pivot Fittings


Channel
15⁄8"

Fitting Open Fitting Closed


Telestrut
System

Rotate to Close
Around Rod
Hardware
Nuts &
General
Fittings

SQUARE
WASHER
Pipe/Conduit

RIVET
Supports

45°

13⁄4"
(44.5)
Electrical
Fittings

9
⁄16"
(14.3)
(TYP)
Concrete
Inserts
11⁄4" Framing

"R"
System

1 FINISH
⁄2"
(12.7) Electro-galvanized (EG), conforming to ASTM B633 Type III SC1.
7
⁄8" Rod “R” - Hole
⁄16" Framing

(22.2) Part Size Diameter


System

Number In (mm) In (mm)


Fitting Shown 3 7
SPF 100-037 ⁄8 ⁄16
Closed 9.5 11.1
13

1 9
SPF 100-050 ⁄2 ⁄16
12.7 14.3
Fiberglass
System

5 11
SPF 100-062 ⁄8 ⁄16
15.9 17.5
3 13
11⁄8" SPF 100-075 ⁄4 ⁄16
(28.6) 19.1 20.6

17⁄8"
Special
Metals

(47.6) Notes:
1. The load capacity of the fitting exceeds the slip and pull-out capacity of the
channel nut.
41⁄8" 2. Allowable loads have been determined by the manufacturers testing, analysis
PrimeAngle

1 (104.8)
⁄4" 15⁄8" 135° and technical specifications.
System

(6.4) (41.3) 3. For retrofit application, engineer of record must verify.


4. Patented.
5. Square washer provided with fitting.
25⁄8"
6. When a hanger rod is thru-bolted (in lieu of channel nut installation),
(66.7)
higher transverse loads may be transmitted due to the higher allowed rod
Product
Index

shear loads compared to channel nut slip values. This higher load may be
used with verification through engineering calculations.

140 General Fittings


Seismic Retrofit Fittings

SPF® 200 Adjustable Seismic Pivot Fittings

Channel
15⁄8"
Rotate to Close

Telestrut
System
Around Rod

Hardware
Nuts &
135° SQUARE
WASHER
RIVET

General
Fittings
Pipe/Conduit
Supports
9
⁄16" 13⁄4"
(14.3) (44.5)
1
⁄4" 15⁄8"
(6.4) 135°
(41.3) 1
⁄2"

Electrical
Fittings
(12.7)
33⁄8" 17⁄8"
(85.7) (47.6)
13⁄4"

Concrete
Inserts
(44.5)

11⁄4" Framing
9
⁄16"

System
(14.3)

FINISH
Electro-galvanized (EG), conforming to ASTM B633 Type III SC1.
Rod “R” - Hole

Framing
Part Size Diameter

System
Number In (mm) In (mm)
3 7
SPF 200-037 ⁄8 ⁄16

13⁄16"
9.5 11.1
1 9
SPF 200-050 ⁄2 ⁄16
2" 12.7 14.3
(50.8)

Fiberglass
5 11
SPF 200-062 ⁄8 ⁄16

System
15.9 17.5
135° 3 13
SPF 200-075 ⁄4 ⁄16
3
⁄4" 19.1 20.6
(19.1)
Special
Metals

Notes:
1. The load capacity of the fitting exceeds the slip and pull-out capacity of the
channel nut.
R
25⁄8" 2. Allowable loads have been determined by the manufacturers testing,
PrimeAngle

(66.7) analysis and technical specifications.


System

3. For retrofit application, engineer of record must verify.


1
⁄2" 4. Patented.
(12.7)
5. Square washer provided with fitting.
6. When a hanger rod is thru-bolted (in lieu of channel nut installation),
higher transverse loads may be transmitted due to the higher allowed rod
Product
Index

shear loads compared to channel nut slip values. This higher load may be
used with verification through engineering calculations.

General Fittings 141


® Seismic Retrofit Fittings

SPF® 300 Seismic Pivot Fittings


Channel
15⁄8"
Telestrut
System
Hardware
Nuts &

SQUARE
WASHER
General
Fittings

WELDED
EYE
Pipe/Conduit
Supports

Rotate to Close
Electrical
Fittings

Around Rod
Concrete
Inserts

13⁄4"
(44.5)
13⁄4"
(44.5) FINISH
11⁄4" Framing

9
⁄16" Electro-galvanized (EG), conforming to ASTM
System

(14.3) B633 Type III SC1.


2"
(50.8) 13
⁄16" Rod “R” - Hole
(20.6) Part Size Diameter
Number In (mm) In (mm)
⁄16" Framing

3 7
SPF 300-037 ⁄8 ⁄16
R WELDED EYE 9.5 11.1
System

2"
1 9
(50.8) 135° SPF 300-050 ⁄2 ⁄16
12.7 14.3
3
⁄8" SPF 300-062 5
⁄8 11
⁄16
13

(9.5) 15.9 17.5


3 13
SPF 300-075 ⁄4 ⁄16
Fiberglass

3
⁄8"
System

19.1 20.6
(9.5)
Notes:
1. The load capacity of the fitting exceeds the slip and
pull-out capacity of the channel nut
Special
Metals

2. Allowable loads have been determined by the


manufacturers testing, analysis and technical
specifications.
3. For retrofit application, engineer of record must
PrimeAngle

verify.
System

4. Patented.
5. Square washer provided with fitting.
6. When a hanger rod is thru-bolted (in lieu of channel
nut installation), higher transverse loads may be
transmitted due to the higher allowed rod shear loads
Product

compared to channel nut slip values. This higher


Index

load may be used with verification through


engineering calculations.

142 General Fittings


Seismic Retrofit Fittings

SPF® 400 Seismic Pivot Fittings

Channel
15⁄8"
LOAD

Telestrut
System
LOAD
Rotate to Close
Around Rod

Hardware
Nuts &
LOAD

LOAD
SLOTTED

General
Fittings
SLOTTED
BOLT SPACER
SQUARE
WASHER

Pipe/Conduit
Supports
3⁄16"
NUT
GALVANIZED
CABLE
GRIPPER

Electrical
Fittings
13⁄4"

Concrete
(44.5)

Inserts
2"
(50.8) 9
⁄16"

11⁄4" Framing
(14.3)

System
135°
R FINISH
2"
Electro-galvanized (EG), conforming to
(50.8)
ASTM B633 Type III SC1.

Framing
3
⁄8" Engagement Tab Rod “R” - Hole
(9.5)

System
Part Size Diameter
Number In (mm) In (mm)
3
⁄8"

13⁄16"
3 7
SPF 400-037 ⁄8 ⁄16
(9.5)
9.5 11.1
Wire 4-Way Splayed Single Cable SPF 400-050 1
⁄2 9
⁄16
Rope Transverse Longitudinal Transverse 12.7 14.3

Fiberglass
System
Diameter Load Load Load 5 11
SPF 400-062 ⁄8 ⁄16
In (mm) lbs (kg) lbs (kg) lbs (kg) 15.9 17.5
3
⁄16 1050 1116 650 SPF 400-075 3
⁄4 13
⁄16
4.8 476 506 295 19.1 20.6
Special
Metals

Notes: Notes:
1. Allowable loads have been determined by the manufacturer’s 1. The load capacity of the fitting exceeds the slip and
testing, analysis, and technical specifications. pull-out capacity of the channel nut.
2. Galvanized Wire Rope, 7 x 19 IWSC, RHRL (PRESTRETCHED). 2. Allowable loads have been determined by the
PrimeAngle

3. Torque on nut/spacer: 50 ft-lbs. manufacturers testing, analysis and technical


System

4. Safety Factor of 3 for prestretched cable. specifications.


3. For retrofit application, engineer of record must verify.
4. When a hanger rod is thru-bolted (in lieu of channel
nut installation), higher transverse loads may be
transmitted due to the higher allowed rod shear loads
Product
Index

compared to channel nut slip values. This higher load


may be used with verification through engineering
calculations.

General Fittings 143


® Seismic Retrofit Fittings

LS 410 Seismic Pivot Fittings


Channel
15⁄8"
Telestrut
System

FINISH
Electro-galvanized (EG), conforming to
Hardware

ASTM B633 Type III SC1.


Nuts &

Anchor “R” - Hole


Part Size Diameter
Number In (mm) In (mm)
3 7
LS 410-037 ⁄8 ⁄16
General

15⁄8"
Fittings

(41.3) 9.5 11.1


1 9
LS 410-050 ⁄2 ⁄16
R 12.7 14.3
5 11
LS 410-062 ⁄8 ⁄16
Pipe/Conduit

15.9 17.5
Supports

1
2 ⁄2" 9
⁄16" LS 410-075 3
⁄4 13
⁄16
135°
(63.5) (14.3) 19.1 20.6
Note:
1. Allowable loads have been determined by the
manufacturers testing, analysis and technical
Electrical
Fittings

2" specifications.
(50.8) 2. For retrofit application, engineer of record must verify.
R
3. Torque on nut/spacer: 50 ft-lbs.
4. Square washer provided with fitting.
Concrete

5. Loads are the same as the SPF 400


Inserts

LS 500 Seismic Pivot Fittings


11⁄4" Framing
System
⁄16" Framing

FINISH
System

Cable, Electro-galvanized (EG), conforming to


Fixed ASTM B633 Type III SC1.
13

Anchor “R” - Hole


Part Size Diameter
R
Fiberglass

21⁄2" Number In (mm) In (mm)


System

(63.5) LS 500-037 3
⁄8 7
⁄16
9.5 11.1
1 9
LS 500-050 ⁄2 ⁄16
12.7 14.3
5 11
Special

LS 500-062 ⁄8 ⁄16
Metals

15.9 17.5
2" LS 500-075 3
⁄4 13
⁄16
(50.8) 19.1 20.6
R
PrimeAngle

Cable Length Note:


System

15⁄8" 096 8' (2.4M) 1. Allowable loads have been determined by the
(41.3) 120 10' (3.0M) manufacturers testing, analysis and technical
Example 144 12' (3.6M)
specifications.
LS500-037-096 180 15' (4.5M)
240 20' (6.1M) 2. For retrofit application, engineer of record must verify.
Product

Cable Length 300 25' (7.6M) 3. Patented


Index

Anchor Size 360 30' (9.1M) 4. Square washer provided with fitting.
Fitting Number 480 40' (12.2M) 5. Loads are the same as the SPF 400

144 General Fittings


®
PIPE/CONDUIT SUPPORTS
Pipe/Conduit Clamps ............................... 147-151
Unicushion® .............................................. 152-153
Pipe & Tubing (Cush-A-Clamp®) Clamps .. 154-157

Pipe Hangers .................................................... 158


Pipe Rollers ............................................... 159-161
Pipe Brackets ............................................ 162-163

Reference Tables ...................................... 164-170

MATERIAL DIMENSIONS
Unistrut pipe clamps, unless noted, are punch-press made Imperial dimensions are illustrated in inches. Metric
from hot-rolled, pickled and oiled steel plates, strip or coil, dimensions are shown in parenthesis or as noted. Unless
and conform to ASTM specifications A1008, A575, A576, noted, all metric dimensions are in millimeters and rounded
A635, or A36. The fitting steel also meets the physical to one decimal place.
requirements of ASTM A1011 SS GR 33. The pickling of the
steel produces a smooth surface free from scale. DESIGN BOLT TORQUE
Many items are also available in stainless steel.
Consult factory for ordering information. BOLT SIZE 1⁄4"-20 5⁄16"-18 3⁄8"-16 1⁄2"-13 5
⁄8"-11 3⁄4"-10
Rec. Torque 6 11 19 50 100 125
FINISHES Ft/Lbs (N•m) (8) (15) (26) (68) (136) (170)
Pipe supports are available in: Max Torque 7 15 25 70 125 150
• Electro-galvanized (EG), conforming to Ft/Lbs (N•m) (9) (20) (34) (95) (170) (203)
ASTM B633 Type III SC1
• Hot-dipped galvanized (HG), conforming to Note: When tightening 1⁄4" screws used with a two piece
ASTM A123 or A153 (hardware) pipe clamp, a torque of 5 foot pounds (60 inch-pounds)
• Perma-Green II (GR), and plain (PL). should be used.

APPLICATION DESIGN LOAD


Unistrut pipe clamps, pipe hangers, brackets and rollers are Design load data, where shown, is based on the ultimate
designed for the support of electrical and mechanical strength of the connection with a safety factor of 5.0,
services. Supports to meet nearly every requirement can be unless otherwise noted.
attained using Unistrut Metal Framing components.

Pipe Clamps In Special Materials (P1109, P1211, P1425, P2024 Series)


Material Add Suffix to P/N Example
Steel Strap, Everdur Hardware E P1109 E
Copper Coated Steel Strap & Hardware CC P1109 CC
Aluminum AL P1109 AL
Stainless Steel 304 or 316 SS or ST P1109 SS
Plastic Coated Steel Straps PC P1109 PC

145
® Pipe & Conduit Pictorial Index

Pipe & Conduit Clamps


Channel
15⁄8"
Telestrut
System

P1109 - Pg 147 P1211 - Pg 149 P1425 - Pg 147 P2024 - Pg 148 P1563 - Pg 149 P2008 - Pg 149
Hardware
Nuts &
General
Fittings

P2558 - Pg 150 P2609 - Pg 150 P3409 - Pg 151 M5025 - Pg 151 P2600 - Pg 152 004T008 - Pg 154
Pipe/Conduit
Supports
Electrical
Fittings
Concrete
Inserts

004M007 - Pg 155 UB1⁄2PA - Pg 156 CG-10 - Pg 157 PUX3834 - Pg 157 J1205 - Pg 158 J1205 - Pg 158
11⁄4" Framing
System

Pipe Rollers
Framing
System
13⁄16"

P2474 - Pg 159 P2474-1 - Pg 160 P2475 - Pg 161 P2476 - Pg 161


Fiberglass
System

Pipe Brackets
Special
Metals
PrimeAngle
System

P2481 - Pg 162 P2482 - Pg 162 P2243 - Pg 162 UP-BK - Pg 163


Product
Index

146 Pipe/Conduit Supports


Pipe & Conduit Clamps

P1109 thru P1126 Pipe Clamps for Rigid Steel Conduit

Channel
15⁄8"
Pipe O.D. Wt/100 Design

Telestrut
Part Size Size Thickness pcs Load

System
Number In In (mm) Gauge (mm) Lbs (kg) Lbs (kg)
3
P1109 ⁄8 0.675 16 10 400
17.1 1.5 4.5 181
1
P1111 ⁄2 0.840 16 11 400

Hardware
21.3 1.5 5.0 181

Nuts &
1 1⁄4"
3
(31.8) P1112 ⁄4 1.050 14 15 600
26.7 1.9 6.8 272
P1113 1 1.315 14 17 600
33.4 1.9 7.7 272

General
Fittings
P1114 11⁄4 1.660 14 19 600
42.2 1.9 8.6 272
Design Load P1115 11⁄2 1.900 12 29 800
48.3 2.7 13.2 363

Pipe/Conduit
P1117 2 2.375 12 34 800

Supports
60.3 2.7 15.4 363
P1118 21⁄2 2.875 12 40 800
73.0 2.7 18.1 363
P1119 3 3.500 12 47 800
88.9 2.7 21.3 363
P1120 31⁄2 4.000 11 62 1,000

Electrical
Fittings
101.6 3.0 28.1 454
P1121 4 4.500 11 67 1,000
114.3 3.0 30.4 454
P1123 5 5.563 11 80 1,000

Concrete
141.3 3.0 36.3 454

Inserts
P1124 6 6.625 10 102 1,000
168.3 3.4 46.3 454
Slotted hex head screw and nut included with EG or HG Finish. P1126 8 8.625 10 130 1,000
219.1 3.4 59.0 454

11⁄4" Framing
System
P1425 thru P1431 Pipe Clamps for Thin Wall Conduit (E.M.T.)
Pipe O.D. Wt/100 Design
Part Size Size Thickness pcs Load
Number In In (mm) Gauge (mm) Lbs (kg) Lbs (kg)

⁄16" Framing
3
P1425 ⁄8 0.577 16 9 400

System
14.7 1.5 4.1 181
1
P1426 ⁄2 0.706 16 11 400
17.9 1.5 5.0 181

13
3
P1427 ⁄4 0.922 16 12 400
1 1⁄4"
(31.8) 23.4 1.5 5.4 181

Fiberglass
System
P1428 1 1.163 14 15 600
29.5 1.9 6.8 272
P1429 11⁄4 1.510 14 18 600
38.4 1.9 8.2 272
P1430 11⁄2 1.740 12 29 800
Special
Metals

44.2 2.7 13.2 363


Design Load
P1431 2 2.197 12 33 800
55.8 2.7 15.0 363
P1118 21⁄2 2.875 12 40 800
73.0 2.7 18.1 363
PrimeAngle
System

P1119 3 3.500 12 47 800


88.9 2.7 21.3 363
P1120 31⁄2 4.000 11 62 1,000
101.6 3.0 28.1 454
P1121 4 4.500 11 67 1,000
Product

114.3 3.0 30.4 454


Index

Slotted hex head screw and nut included with EG or HG Finish.

Pipe/Conduit Supports 147


® Pipe & Conduit Clamps

P2024 thru P2070-84 Pipe Clamps for O.D. Tubing


Channel
15⁄8"

Slotted hex head screw and nut included with


Telestrut
System

EG or HG Finish.
P2024 - P2029 16 ga.
P2030 - P2035 14 ga. 1 1⁄4"
P2037 - P2052 12 ga. (31.8)
P2053 - P2066 11 ga.
Hardware
Nuts &

P2067 - P2070-84 10 ga.

Design Load
General
Fittings

O.D. Wt/100 Design O.D. Wt/100 Design O.D. Wt/100 Design


Part Size pcs Load Part Size pcs Load Part Size pcs Load
Number In (mm) Lbs (kg) Lbs (kg) Number In (mm) Lbs (kg) Lbs (kg) Number In (mm) Lbs (kg) Lbs (kg)
Pipe/Conduit

1
P2024 ⁄4 8 P2047 31⁄8 43 P2070 6 94
Supports

6.4 3.6 79.4 19.5 152.4 42.6


3
P2025 ⁄8 8 400 P2048 31⁄4 45 800 P2070-61 61⁄8 96
9.5 3.6 181 82.6 20.4 363 155.6 43.5
1
P2026 ⁄2 9 P2049 33⁄8 46 P2070-62 61⁄4 98
12.7 4.1 85.7 20.9 158.8 44.5
Electrical
Fittings

5
P2027 ⁄8 10 P1119 31⁄2 47 P2070-63 63⁄8 99 1,000
15.9 4.5 88.9 21.3 161.9 44.9 454
3
P2028 ⁄4 11 P2051 35⁄8 56 P2070-64 61⁄2 100
19.1 5.0 92.1 25.4 165.1 45.4
7
P2029 ⁄8 12 P2052 33⁄4 58 P1124 65⁄8 102
Concrete
Inserts

22.2 5.4 95.3 26.3 168.3 46.3


P2030 1 14 P2053 37⁄8 60 1,000 P2070-66 63⁄4 104
25.4 6.4 98.4 27.2 454 171.5 47.2
P2031 11⁄8 15 600 P1120 4 62 P2070-67 67⁄8 106
28.6 6.8 272 101.6 28.1 174.6 48.1
11⁄4" Framing

P2032 11⁄4 16 P2055 41⁄8 62 P2070-70 7 108


System

31.8 7.3 104.8 28.1 177.8 49.0


P2033 13⁄8 17 P2056 41⁄4 64 P2070-71 71⁄8 110
34.9 7.7 108.0 29.0 181.0 49.9
P2034 11⁄2 18 P2057 43⁄8 66 P2070-72 71⁄4 112
38.1 8.2 111.1 29.9 184.2 50.8
Framing

P2035 15⁄8 19 P1121 41⁄2 67 P2070-73 73⁄8 114


System

41.3 8.6 114.3 30.4 187.3 51.7


P1430 13⁄4 29 P2059 45⁄8 70 P2070-74 71⁄2 116
13⁄16"

44.5 13.2 117.5 31.8 190.5 52.6


P2037 17⁄8 28 P2060 43⁄4 72 P2070-75 75⁄8 117
47.6 12.7 120.7 32.7 193.7 53.1
Fiberglass

P2038 2 31 800 P2061 47⁄8 73 P2070-76 73⁄4 119


System

50.8 14.1 363 123.8 33.1 196.9 54.0


P2039 21⁄8 32 P2062 5 74 P2070-77 77⁄8 121
54.0 14.5 127.0 33.6 200.0 54.9
P2040 21⁄4 33 P2063 51⁄8 76 P2070-80 8 123
57.2 15.0 130.2 34.5 203.2 55.8
Special
Metals

P1117 23⁄8 34 P2064 51⁄4 77 P2070-81 81⁄8 125


60.3 15.4 133.4 34.9 206.4 56.7
P2042 21⁄2 35 P2065 53⁄8 78 P2070-82 81⁄4 126
63.5 15.9 136.5 35.4 209.6 57.2
PrimeAngle

25⁄8 51⁄2 83⁄8


System

P2043 37 P2066 79 P2070-83 128


66.7 16.8 139.7 35.8 212.7 58.1
P2044 23⁄4 38 P2067 55⁄8 88 P2070-84 81⁄2 129
69.9 17.2 142.9 39.9 215.9 58.5
P1118 27⁄8 40 P2068 53⁄4 90 P1126 85⁄8 130
73.0 18.1 146.1 40.8 219.1 59.0
Product
Index

P2046 3 41 P2069 57⁄8 92


76.2 18.6 149.2 41.7

148 Pipe/Conduit Supports


Pipe & Conduit Clamps

P1211 thru P1217 Universal Clamps for Rigid or Thinwall Conduit

Channel
15⁄8"
Part Pipe/Conduit Size Thickness Wt/100 pcs Design Load
Number In Gauge (mm) Lbs (kg) Lbs (kg)
1
P1211 ⁄2 16 10 400

Telestrut
System
1.5 4.5 181
3
P1212 ⁄4 16 11 400
1 1⁄4" 1.5 5.0 181
(31.8) P1213 1 16 12 400

Hardware
1.5 5.4 181

Nuts &
P1214 11⁄4 14 18 600
1.9 8.2 272
P1215 11⁄2 14 20 600
1.9 9.1 272

General
Fittings
Design Load P1217 2 14 22 600
1.9 10.0 272
Slotted hex head screw and nut included with EG or HG Finish.

P1563 thru P1573 Parallel Clamps for Rigid Conduit and Pipe

Pipe/Conduit
Supports
Part Pipe Size O.D. Size Thickness Wt/100 pcs
Number In In (mm) Gauge (mm) Lbs (kg)
3
P1563 ⁄8 0.675 14 27
17.1 1.9 12.2
1
P1564 ⁄2 0.840 14 29
1 3⁄8"

Electrical
Fittings
(34.9) 21.3 1.9 13.2
3
P1565 ⁄4 1.050 14 30
26.7 1.9 13.6
P1566 1 1.315 14 31
33.4 1.9 14.1

Concrete
Inserts
P1567 11⁄4 1.660 14 38
42.2 1.9 17.2
P1568 11⁄2 1.900 12 40
48.3 2.7 18.1

11⁄4" Framing
P1569 2 2.375 12 47
60.3 2.7 21.3

System
P1570 21⁄2 2.875 12 66
73.0 2.7 29.9
P1571 3 3.500 12 78
88.9 2.7 35.4
P1572 31⁄2 4.000 12 87

⁄16" Framing
101.6 2.7 39.5

System
Slotted hex head screw and nut included. P1573 4 4.500 12 90
Finish: Electro-galvanized. 114.3 2.7 40.8

13
P2008 thru P2020 One Hole Clamp for O.D. Tubing

Fiberglass
Part O.D. Tube Size Thickness Wt/100 pcs

System
Number In (mm) Gauge (mm) Lbs (kg)
1
P2008 ⁄4 16 4
6.4 1.5 1.8
5
P2009 ⁄16 16 5
Special

7.9 1.5 2.3


Metals
1
⁄4" X 3⁄4" Round Head
3
Machine Screw P2010 ⁄8 16 5
and Channel Nut 9.5 1.5 2.3
Not Included 1
P2012 ⁄2 16 6
12.7 1.5 2.7
PrimeAngle
System

5
P2014 ⁄8 14 8
15.9 1.9 3.6
3
P2016 ⁄4 14 9
19.1 1.9 4.1
7
P2018 ⁄8 14 10
Product

22.2 1.9 4.5


Index

P2020 1 14 11
Finish: Electro-galvanized and Aluminum 25.4 1.9 5.0

Pipe/Conduit Supports 149


® Pipe & Conduit Clamps

P2558-5 thru P2558-60 Single Piece Pipe Strap


Channel
15⁄8"

Nominal Wt/100 Design


Part Pipe Size A “B” C Thickness pcs Load
A ± ⁄8"
1
Number In In (mm) In (mm) In (mm) In (mm) Lbs (kg) Lbs (kN)
Telestrut
System

1
P2558-05 ⁄2 27⁄8 23
C 73.0 10.4
Hole P2558-07 3
⁄4 31⁄8 26
Size B 79.4 11.8
99⁄32 7 7⁄16 11⁄8
Hardware

P2558-10 1 33⁄8 ⁄32 ⁄16 ⁄8 31 500


500
Nuts &

85.7 7.1
7.1 11.1
11.1 3.2
3.2 14.1 2.2
2.2
P2558-12 11⁄4 33⁄4 35
95.3 15.9
P2558-15 11⁄2 37⁄8 39
General
Fittings

98.4 17.7
Design Load
P2558-20 2 53⁄4 94
Hardware sold separately. 146.1 42.6
P2558-25 21⁄2 61⁄4 114
158.8 51.7
Pipe/Conduit
Supports

Supporting P2558-30 3 67⁄8 133


Rib on 174.6 60.3
P2558-60 77⁄16 1111⁄16 11⁄4 1,000
P2558-35 31⁄2 73⁄8 ⁄16 ⁄16 ⁄4 152 1,000
187.3 11.1
11.1 17.5
17.5 6.4
6.4 68.9 4.4
4.4
P2558-40 4 77⁄8 176
200.0 79.8
Electrical
Fittings

P2558-50 5 9 198
228.6 89.8
P2558-60 6 10 225
254.0 102.1
Concrete
Inserts

P2609 thru P2617, P2426 thru P2431 UNI-CLIP® Support


11⁄4" Framing
System

The Uni-Clip supports meet or exceed load


requirements for American Standard Code
for Pressure Piping (1967), and National
Electric Code (1971).
Framing

Patent No. 2863625.


System

Material: Stainless steel type 301.


13⁄16"

UNI-CLIP® SUPPORTS FOR UNI-CLIP® SUPPORTS FOR


THINWALL CONDUIT (E.M.T.) RIGID STEEL CONDUIT
Fiberglass
System

Part Conduit Size O.D. Size Wt/100 pcs Part Conduit Size O.D. Size Wt/100 pcs
Number In In (mm) Lbs (kg) Number In In (mm) Lbs (kg)
1 3
P2426 ⁄2 0.706 1.7 P2609 ⁄8 0.675 1.6
17.9 0.8 17.1 0.7
3 1
P2427 ⁄4 0.922 2.4 P2611 ⁄2 0.840 2.3
Special
Metals

23.4 1.1 21.3 1.0


3
P2428 1 1.163 3.6 P2612 ⁄4 1.050 3.2
29.5 1.6 26.7 1.5
P2429 11⁄4 1.510 4.6 P2613 1 1.315 4.1
PrimeAngle

38.4 2.1 33.4 1.9


System

P2430 11⁄2 1.740 5.9 P2614 11⁄4 1.660 5.1


44.2 2.7 42.2 2.3
P2431 2 2.197 8 P2615 11⁄2 1.900 6.3
55.8 3.6 48.3 2.9
P2617 2 2.375 10
Product
Index

60.3 4.5

150 Pipe/Conduit Supports


Pipe & Conduit Clamps

P3409 thru P3417 Stand-off Pipe Clamps

Channel
15⁄8"
A B

Telestrut
Hardware included.

System
Finish: Electro-galvanized.
E Pipe Clamp 11⁄4" Wide
Patent No. 3417951.
Safety factor of 5

Hardware
Nuts &
C
Part Load “D” Load “E” D Part Pipe Size O.D. Size A B C Wt/100 pcs

General
Fittings
Number Lbs (kN) Lbs (kN) Number In In (mm) In (mm) In (mm) Gauge (mm) Lbs (kg)
3
P3409 100 25 P3409 ⁄8 0.675 11⁄8 21⁄8 14 14
45.4 11.3 17.1 28.6 54.0 1.9 6.4
1
P3411 150 35 P3411 ⁄2 0.840 11⁄4 25⁄16 14 15

Pipe/Conduit
68.0 15.9 21.3 31.8 58.7 1.9 6.8

Supports
3
P3412 175 40 P3412 ⁄4 1.050 15⁄16 21⁄2 14 19
79.4 18.1 26.7 33.3 63.5 1.9 8.6
P3413 200 50 P3413 1 1.315 11⁄2 23⁄4 14 22
90.7 22.7 33.4 38.1 69.9 1.9 10.0
P3414 300 70 P3414 11⁄4 1.660 111⁄16 31⁄4 12 34
42.2 42.9 82.6 2.7 15.4

Electrical
136.1 31.8

Fittings
P3415 400 80 P3415 11⁄2 1.900 13⁄4 31⁄2 11 49
181.4 36.3 48.3 44.5 88.9 3.0 22.2
P3417 500 120 P3417 2 2.375 2 4 10 55
226.8 54.4 60.3 50.8 101.6 3.4 24.9

Concrete
Inserts
M5025 thru M5060 One-piece Cable and Conduit Clamps
Part Max O.D. Size “A” “B” “C” Wt/100 pcs

11⁄4" Framing
Number In (mm) In (mm) In (mm) Gauge (mm) Lbs (kg)

System
3 7
M5025 ⁄8 ⁄16 15⁄8 14 6
9.5 11.1 41.3 1.9 2.7
1 9
M5026 ⁄2 ⁄16 13⁄4 14 7
12.7 14.3 44.5 1.9 3.2
3 13
M5028 ⁄4 ⁄16 2 14 12
19.1 20.6 50.8 1.9 5.4

⁄16" Framing
M5030 1 11⁄16 21⁄4 14 15

System
25.4 27.0 57.2 1.9 6.8
M5032 11⁄4 15⁄16 21⁄2 14 19
31.8 33.3 63.5 1.9 8.6

13
M5034 11⁄2 19⁄16 23⁄4 14 20
38.1 39.7 69.9 1.9 9.1

Fiberglass
13⁄4 113⁄16

System
M5036 3 12 25
44.5 46.0 76.2 2.7 11.3
M5038 2 21⁄16 31⁄4 12 35
B 50.8 52.4 82.6 2.7 15.9
M5041 23⁄8 27⁄16 35⁄8 12 41
Special
Metals

60.3 61.9 92.1 2.7 18.6


M5044 23⁄4 213⁄16 4 12 60
A C
69.9 71.4 101.6 2.7 27.2
M5048 31⁄4 35⁄16 41⁄2 12 74
PrimeAngle

82.6 84.1 114.3 2.7 33.6


System

M5052 33⁄4 313⁄16 5 12 91


95.3 96.8 127.0 2.7 41.3
M5054 4 41⁄16 51⁄4 12 100
101.6 103.2 133.4 2.7 45.4
M5057 43⁄8 47⁄16 55⁄8 10 115
Product

111.1 112.7 142.9 3.4 52.2


Index

Finish: Electro-galvanized and Aluminum. M5060 43⁄4 413⁄16 6 10 125


120.7 122.2 152.4 3.4 56.7

Pipe/Conduit Supports 151


® UNICUSHION®

P2600 UNICUSHION®: Isolation Material


Channel
15⁄8"

Wt/Carton: 2.5 Lbs (1.1 kg)


Telestrut
System
Hardware
Nuts &
General
Fittings

UNICUSHION FEATURES

• Shock absorption
• Protection from corrosion and abrasion
• Allowance for expansion and contraction
Pipe/Conduit

• Sound and vibration isolation


Supports

• Stability in use from - 50° F (-47° C) to + 350°F (+177° C)


• 25 feet per carton.
• Flexible elastomer material
• Cut to length as shown in charts.
• Will not support combustion
Electrical
Fittings

Clamp Selection & Cutting Guide UNICUSHION®


STANDARD PIPE OR
EMT CONDUIT RIGID CONDUIT COPPER TUBING TYPE K OR L
Use UNICUSHION Use UNICUSHION Use UNICUSHION
Concrete
Inserts

Nominal with Length Nominal with Length Nominal with Length


Size Clamp In (mm) Size Clamp In (mm) Size Clamp In (mm)
3
⁄8" P1426 13⁄4 3
⁄8" P1111 21⁄8 1
⁄4" P2026 11⁄16
44.5 54.0 27.0
11⁄4" Framing

1
⁄2" P1111 21⁄8 1
⁄2" P2030 3 3
⁄8" P2027 11⁄2
System

54.0 76.2 38.1


3
⁄4" P1112 23⁄4 3
⁄4" P2031 31⁄4 1
⁄2" P2028 21⁄8
69.9 82.6 54.0
1" P2032 35⁄8 1" P2034 41⁄4 5
⁄8" P2029 21⁄4
92.1 108.0 57.2
11⁄4" P2035 43⁄4 11⁄4" P2037 51⁄4 3
⁄4" P2030 3
Framing

120.7 133.4 76.2


System

11⁄2" P2037 51⁄2 11⁄2" P2038 6 1" P2032 35⁄8


139.7 152.4 92.1
13⁄16"

2" P1117 63⁄4 2" P2042 71⁄2 11⁄4" P2034 41⁄2


171.5 190.5 114.3
21⁄2" P2046 9 11⁄2" P1430 51⁄4
Fiberglass

228.6 133.4
System

3" P2051 11 2" P2040 63⁄4


279.4 171.5
31⁄2" P2055 121⁄4 21⁄2" P2044 81⁄4
311.2 209.6
Special
Metals

4" P2059 14 3" P2048 10


355.6 254.0
5" P2067 171⁄2 31⁄2" P2052 111⁄4
444.5 285.8
PrimeAngle

6" P2070-66 203⁄4 4" P2056 121⁄2


System

527.1 317.5
5" P2064 16
406.4
6" P2070-62 19
482.6
Product

8" P2070-82 25
Index

635.0

152 Pipe/Conduit Supports


UNICUSHION®

Clamp Selection & Cutting Guide (continued) UNICUSHION®

Channel
15⁄8"
Telestrut
System
O. D. Use UNICUSHION O. D. Use UNICUSHION O. D. Use UNICUSHION
Size With Length Size With Length Size With Length
In (mm) Clamp In (mm) In (mm) Clamp In (mm) In (mm) Clamp In (mm)

Hardware
1 7
⁄4 P2025 ⁄8 31⁄8 P2048 10 6 P2070-61 181⁄2

Nuts &
6.4 22.2 79.4 254.0 152.4 469.9
3
⁄8 P2026 11⁄16 31⁄4 P2049 101⁄2 61⁄8 P2070-62 19
9.5 27.0 82.6 266.7 155.6 482.6
1
⁄2 P2027 11⁄2 33⁄8 P1119 103⁄4 61⁄4 P2070-63 191⁄4

General
Fittings
12.7 38.1 85.7 273.1 158.8 489.0
5
⁄8 P2028 21⁄8 31⁄2 P2051 11 63⁄8 P2070-64 193⁄4
15.9 54.0 88.9 279.4 161.9 501.7
3
⁄4 P2029 21⁄4 35⁄8 P2052 111⁄4 61⁄2 P1124 20
19.1 57.2 92.1 285.8 165.1 508.0

Pipe/Conduit
Supports
7
⁄8 P2030 3 33⁄4 P2053 111⁄2 65⁄8 P2070-66 201⁄2
22.2 76.2 95.3 292.1 168.3 520.7
1 P2031 31⁄4 37⁄8 P1120 113⁄4 63⁄4 P2070-67 21
25.4 82.6 98.4 298.5 171.5 533.4
11⁄8 P2032 35⁄8 4 P2055 12 67⁄8 P2070-70 211⁄4
28.6 92.1 101.6 304.8 174.6 539.8

Electrical
Fittings
11⁄4 P2033 4 41⁄8 P2056 121⁄2 7 P2070-71 213⁄4
31.8 101.6 104.8 317.5 177.8 552.5
13⁄8 P2034 41⁄2 41⁄4 P2057 13 71⁄8 P2070-72 22
34.9 114.3 108.0 330.2 181.0 558.8
11⁄2 47⁄8 43⁄8 131⁄2 71⁄4 221⁄2

Concrete
P2035 P1121 P2070-73

Inserts
38.1 123.8 111.1 342.9 184.2 571.5
15⁄8 P1430 51⁄4 41⁄2 P2059 14 73⁄8 P2070-74 223⁄4
41.3 133.4 114.3 355.6 187.3 577.9
13⁄4 P2037 51⁄2 45⁄8 P2060 141⁄4 71⁄2 P2070-75 231⁄4

11⁄4" Framing
44.5 139.7 117.5 362.0 190.5 590.6

System
17⁄8 P2038 6 43⁄4 P2061 143⁄4 75⁄8 P2070-76 231⁄2
47.6 152.4 120.7 374.7 193.7 596.9
2 P2039 61⁄2 47⁄8 P2062 15 73⁄4 P2070-77 24
50.8 165.1 123.8 381.0 196.9 609.6
21⁄8 P2040 63⁄4 5 P2063 151⁄2 77⁄8 P2070-80 241⁄2

⁄16" Framing
54.0 171.5 127.0 393.7 200.0 622.3
21⁄4 71⁄4 51⁄8 243⁄4

System
P1117 P2064 16 8 P2070-81
57.2 184.2 130.2 406.4 203.2 628.7
23⁄8 P2042 71⁄2 51⁄4 P2065 161⁄4 81⁄8 P2070-82 25
60.3 190.5 133.4 412.8 206.4 635.0

13
21⁄2 P2043 8 53⁄8 P2066 161⁄2 81⁄4 P2070-83 251⁄2
63.5 203.2 136.5 419.1 209.6 647.7

Fiberglass
System
25⁄8 P2044 81⁄4 51⁄2 P2067 17 83⁄8 P2070-84 26
66.7 209.6 139.7 431.8 212.7 660.4
23⁄4 P1118 83⁄4 55⁄8 P2068 171⁄2 81⁄2 P1126 261⁄4
69.9 222.3 142.9 444.5 215.9 666.8
27⁄8 P2046 91⁄4 53⁄4 P2069 173⁄4
Special
Metals

73.0 235.0 146.1 450.9


3 P2047 91⁄2 57⁄8 P2070 181⁄4
76.2 241.3 149.2 463.6
PrimeAngle
System
Product
Index

Pipe/Conduit Supports 153


® Pipe & Tubing Clamps

004T008 thru 098N106, 009N012 thru 106N114 CUSH-A-CLAMP® Assembly


Channel
15⁄8"

Tube Series Assembly


Controlled Squeeze Copper Copper
Shoulder Bolt & Steel Water Dimensions Wt/100
Telestrut

Part Tube O. D. Pipe “A” “B” “C” “D” pcs


System

Number Size (Nominal) In(mm) In(mm) In(mm) In(mm) Lbs(kg)


1
004T008 ⁄4 0.25 0.62 0.98 0.27 10
C 6.4 15.7 24.9 6.9 4.5
A 3 1
006T010 ⁄8 ⁄4 0.37 0.82 1.13 0.33 11
D
Hardware

9.4 20.8 28.7 8.4 5.0


Nuts &

1 3
“Living 008T012 ⁄2 ⁄8 0.50 0.94 1.34 0.40 13
B Hinge” 12.7 23.9 34.0 10.2 5.9
5 1
010T014 ⁄8 ⁄2 0.62 1.06 1.54 0.46 14
15.7 26.9 39.1 11.7 6.4
General
Fittings

3 5
Materials: 012T016 ⁄4 ⁄8 0.75 1.20 1.68 0.52 14
Clamp: Electro-galvanized or stainless steel. 19.1 30.5 42.7 13.2 6.4
7 3
Cushion: Thermoplastic elastomer. 014T018 ⁄8 ⁄4 0.87 1.31 1.82 0.58 15
Includes cushion, clamp and hardware. 22.1 33.3 46.2 14.7 6.8
Temperature Rating: 016T020 1 1.00 1.44 1.95 0.65 17
Pipe/Conduit

25.4 36.6 49.5 16.5 7.7


Supports

-50°F to +275°F (-45°C to +135°C)


018T022 11⁄8 1 1.12 1.57 2.08 0.70 18
Insert Width: 1.56" (39.6)
28.4 39.9 52.8 17.8 8.2
PIPE/TUBING CLAMPS 020T024 11⁄4 1.25 1.70 2.21 0.77 18
Patent Numbers: 4,516,296; 4,934,635 5 31.8 43.2 56.1 19.6 8.2
FOR
Part Numbers are "coded" to designate cushion size and
1 ⁄ 8" (41 MM) WIDTH SERIES CHANNEL
022T026 13⁄8 11⁄4 1.37 1.82 2.34 0.83 20
clamp size. Examples: 34.8 46.2 59.4 21.1 9.1
Electrical
Fittings

004T008 004 - Cushion Size 4⁄16" (6.4) 024N028 11⁄2 1.50 1.95 2.47 0.90 33
T - With Controlled Squeeze Shoulder Bolt 38.1 49.5 62.7 22.9 15.0
008 - Clamp Size 8⁄16" (12.7) 026N030 15⁄8 11⁄2 1.62 2.07 2.60 0.96 35
41.1 52.6 66.0 24.4 15.9
009N012 009 - Cushion Size 9⁄16" (14.3) 028N032 13⁄4 1.75 2.20 2.73 1.02 37
Concrete
Inserts

N - With Standard Bolt 44.5 55.9 69.3 25.9 16.8


012 - Clamp Size 12⁄16" (19.1) 030N034 17⁄8 1.87 2.32 2.86 1.09 39
47.5 58.9 72.6 27.7 17.7
Pipe Series Assembly 032N036 2 2.00 2.45 3.04 1.15 46
50.8 62.2 77.2 29.2 20.9
11⁄4" Framing

Nominal Dimensions Wt/100


034N040 21⁄8 2.12 2.57 3.23 1.27 47
System

Part Pipe “A” “B” “C” “D” pcs


Number Size In(mm) In(mm) In(mm) In(mm) Lbs(kg) 53.8 65.3 82.0 32.3 21.3
1 038N044 23⁄8 2.37 2.82 3.67 1.41 49
009N012 ⁄4 0.54 0.98 1.34 0.43 13
60.2 71.6 93.2 35.8 22.2
13.7 24.9 34.0 10.9 5.9
3 040N046 21⁄2 2.50 2.94 3.79 1.46 51
011N014 ⁄8 0.67 1.13 1.54 0.49 14 63.5 74.7 96.3 37.1 23.1
17.0 28.7 39.1 12.4 6.4
Framing

1
042N048 25⁄8 2.62 3.07 3.92 1.53 55
014N018 ⁄2 0.84 1.29 1.82 0.58 15
System

66.5 78.0 99.6 38.9 24.9


21.3 32.8 46.2 14.7 6.8 046N052 27⁄8 2.87 3.32 4.17 1.66 57
3
017N022 ⁄4 1.05 1.50 1.95 0.70 17 72.9 84.3 105.9 42.2 25.9
13⁄16"

26.7 38.1 49.5 17.8 7.7 050N054 3 3.00 3.57 4.42 1.78 60
021N026 1 1.31 1.76 2.34 0.81 19 76.2 90.7 112.3 45.2 27.2
33.3 44.7 59.4 20.6 8.6 050N056 31⁄8 3.12 3.57 4.42 1.78 60
Fiberglass

027N032 11⁄4 79.2 90.7 112.3 45.2 27.2


System

1.66 2.17 2.73 0.99 35


42.2 55.1 69.3 25.1 15.9 053N060 35⁄16 3.31 3.96 4.75 1.90 62
030N034 1 ⁄2 1
1.90 2.35 2.86 1.09 39 84.1 100.6 120.7 48.3 28.1
48.3 59.7 72.6 27.7 17.7 056N062 31⁄2 3.50 3.95 4.79 1.97 55
038N044 2 2.37 2.82 3.67 1.41 49 88.9 100.3 121.7 50.0 24.9
Special

058N064 35⁄8 3.62 4.20 4.99 2.03 70


Metals

60.2 71.6 93.2 35.8 22.2


046N052 2 ⁄2 1
2.87 3.32 4.17 1.66 57 91.9 106.7 126.7 51.6 31.8
72.9 84.3 105.9 42.2 25.9 064N072 4 4.00 4.45 5.42 2.28 88
101.6 113.0 137.7 57.9 39.9
056N062 3 3.50 3.95 4.79 1.97 55
066N074 41⁄8 4.12 4.57 5.54 2.34 94
PrimeAngle

88.9 100.3 121.7 50.0 24.9


104.6 116.1 140.7 59.4 42.6
System

1
064N072 3 ⁄2 4.00 4.45 5.42 2.28 88
069N076 45⁄16 4.34 4.96 5.84 2.40 100
101.6 113.0 137.7 57.9 39.9
110.2 126.0 148.3 61.0 45.4
072N080 4 4.50 4.95 5.92 2.53 110
072N080 41⁄2 4.50 4.95 5.92 2.53 110
114.3 125.7 150.4 64.3 49.9
114.3 125.7 150.4 64.3 49.9
089N096 5 5.56 6.01 6.92 3.06 130 082N090 51⁄8 5.12 5.57 6.54 2.84 125
Product

141.2 152.7 175.8 77.7 59.0


Index

130.0 141.5 166.1 72.1 56.7


106N114 6 6.62 7.07 8.23 3.59 140 098N106 61⁄8 6.12 6.57 7.54 3.34 130
168.1 179.6 209.0 91.2 63.5 155.4 166.9 191.5 84.8 59.0

154 Pipe/Conduit Supports


Pipe & Tubing Clamps

004M007 thru 034M040 CUSH-A-CLAMP® Assembly Omega Series™

Channel
15⁄8"
F

Telestrut
System
A
G
C

Hardware
Nuts &
E
E H
D J
Includes clamp and cushion. B

General
Fittings
Materials: Clamp: ZD or stainless steel.
Note: Cannot be mounted on the slotted side of metal framing channel.
Cushion: Thermoplastic elastomer..
Can be mounted to any flat surface.

Copper Copper

Pipe/Conduit
& Steel Water Pipe

Supports
Tubing Pipe Size Dimensions Wt/100
Part O. D. (Nominal)(Nominal) “A” “B” “C” “D” “E” “F” “G” “H” “J” pcs
Number In In In In (mm) In (mm) In (mm) In (mm) In (mm) In (mm) In (mm) In (mm) In (mm) Lbs (kg)
1
004M007 ⁄4 0.25 1.81 0.06 0.60 0.20 0.53 0.48 0.62 0.78 3.4
6.4 46.0 1.5 15.2 5.1 13.5 12.2 15.7 19.8 1.5

Electrical
3 1
006M008 ⁄8 ⁄4 0.37 1.90 0.06 0.65 0.20 0.62 0.62 0.62 0.81 4.0

Fittings
9.4 48.3 1.5 16.5 5.1 15.7 15.7 15.7 20.6 1.8
1 3 1
008M011 ⁄2 ⁄8 ⁄4 0.50 2.20 0.06 0.80 0.26 0.82 0.75 0.75 0.98 5.5
12.7 55.9 1.5 20.3 6.6 20.8 19.1 19.1 24.9 2.5
5 1 3
010M013 ⁄8 ⁄2 ⁄8 0.62 2.32 0.06 0.86 0.26 0.94 0.87 0.75 0.98 6.0

Concrete
15.7 58.9 1.5 21.8 6.6 23.9 22.1 19.1 24.9 2.7

Inserts
3 5
012M015 ⁄4 ⁄8 0.75 2.41 0.06 0.90 0.26 1.03 1.01 0.75 0.98 6.5
19.1 61.2 1.5 22.9 6.6 26.2 25.7 19.1 24.9 2.9
7 3 1
014M017 ⁄8 ⁄4 ⁄2 0.87 2.56 0.06 0.98 0.26 1.18 1.03 0.75 0.98 7.1
22.1 65.0 1.5 24.9 6.6 30.0 26.2 19.1 24.9 3.2

11⁄4" Framing
016M019 1 1.00 2.68 0.06 1.04 0.26 1.31 1.25 0.75 0.98 7.8

System
25.4 68.1 1.5 26.4 6.6 33.3 31.8 19.1 24.9 3.5
3
018M020 ⁄4 1.05 2.68 0.06 1.04 0.26 1.31 1.25 0.75 0.98 8.1
26.7 68.1 1.5 26.4 6.6 33.3 31.8 19.1 24.9 3.7
018M021 11⁄8 1 1.12 2.82 0.06 1.11 0.26 1.44 1.33 0.75 0.98 8.4
28.4 71.6 1.5 28.2 6.6 36.6 33.8 19.1 24.9 3.8

⁄16" Framing
020M024 11⁄4 1.25 3.00 0.08 1.20 0.26 1.65 1.47 1.25 1.56 17

System
31.8 76.2 2.0 30.5 6.6 41.9 37.3 31.8 39.6 7.7
021M026 1 1.31 3.12 0.08 1.26 0.26 1.76 1.71 1.25 1.56 20
33.3 79.2 2.0 32.0 6.6 44.7 43.4 31.8 39.6 9.1

13
022M026 13⁄8 11⁄4 1.37 3.12 0.08 1.26 0.26 1.76 1.71 1.25 1.56 19
34.8 79.2 2.0 32.0 6.6 44.7 43.4 31.8 39.6 8.6

Fiberglass
024M028 11⁄2 1.50 3.65 0.08 1.42 0.26 1.93 1.88 1.25 1.56 20

System
38.1 92.7 2.0 36.1 6.6 49.0 47.8 31.8 39.6 9.1
026M030 15⁄8 11⁄2 1.62 3.77 0.08 1.48 0.26 2.07 2.00 1.25 1.56 23
41.1 95.8 2.0 37.6 6.6 52.6 50.8 31.8 39.6 10.4
027M032 11⁄4 1.66 3.90 0.10 1.55 0.33 2.21 2.12 1.25 1.56 32
42.2 99.1 2.5 39.4 8.4 56.1 53.8 31.8 39.6 14.5
Special
Metals

028M032 13⁄4 1.75 3.90 0.10 1.55 0.33 2.21 2.12 1.25 1.56 32
44.5 99.1 2.5 39.4 8.4 56.1 53.8 31.8 39.6 14.5
030M034 17⁄8 11⁄2 1.87 4.02 0.10 1.61 0.33 2.33 2.25 1.25 1.56 34
47.5 102.1 2.5 40.9 8.4 59.2 57.2 31.8 39.6 15.4
PrimeAngle

032M036 2 2.00 4.15 0.10 1.67 0.33 2.46 2.38 1.25 1.56 36
System

50.8 105.4 2.5 42.4 8.4 62.5 60.5 31.8 39.6 16.3
034M040 21⁄8 2.12 4.40 0.10 1.80 0.33 2.71 2.62 1.25 1.56 41
53.8 111.8 2.5 45.7 8.4 68.8 66.5 31.8 39.6 18.6
038M044 2 2.37 4.71 0.10 1.94 0.33 2.96 2.88 1.25 1.56 44
60.2 119.6 2.5 49.3 8.4 75.2 73.2 31.8 39.6 20.0
Product
Index

082M090 51⁄8 5.12 7.64 0.10 3.41 0.40 5.83 6.75 1.25 1.56 120
130.0 194.1 2.5 86.6 10.2 148.1 171.5 31.8 39.6 54.4

Pipe/Conduit Supports 155


® Pipe & Tubing Clamps

UB1⁄2PA thru UB12PA CUSH–A–CLAMP® Assembly U-Bolt Series


Channel
15⁄8"
Telestrut
System

30°
(0.17π)
A E A
30°
(0.17π)
Hardware

D
Nuts &

E
D
B H C
General

1
Fittings

⁄2" thru 6" assembly.

Includes U bolt, cushion, and hardware.


Materials: B H C
U Bolt: Electro-galvanized finish or Type 316SS
Pipe/Conduit

8" thru 12" assembly.


Supports

Cushion: Thermoplastic elastomer.


Note: Not intended for use with metal framing components due to the length
of the thread.

Pipe
Size Dimensions Wt/100
Electrical
Fittings

Part (Nominal) “A” “B” “C” “D” “E” “F” pcs


Number In In (mm) In (mm) In (mm) In (mm) In (mm) In (mm) H Lbs (kg)
UB1⁄2PA 1
⁄2 0.84 1.60 0.68 1.5 0.67 1
⁄4 1
⁄4-20 UNC-2B 9
21.3 40.6 17.3 38.1 17.0 6.4 4.1
UB3⁄4PA 3
⁄4 1.05 1.80 0.68 1.6 0.78 1
⁄4 1
⁄4-20 UNC-2B 10
Concrete
Inserts

26.7 45.7 17.3 40.6 19.8 6.4 4.5


1 1
UB1PA 1 1.31 2.05 0.68 1.7 0.91 ⁄4 ⁄4-20 UNC-2B 12
33.3 52.1 17.3 43.2 23.1 6.4 5.4
UB11⁄4PA 11⁄4 1.66 2.54 1.24 2.1 1.08 3
⁄8 3
⁄8-16 UNC-2B 36
11⁄4" Framing

42.2 64.5 31.5 53.3 27.4 9.5 16.3


System

UB11⁄2PA 11⁄2 1.90 2.78 1.24 2.2 1.19 3


⁄8 3
⁄8-16 UNC-2B 32
48.3 70.6 31.5 55.9 30.2 9.5 14.5
3 3
UB2PA 2 2.37 3.32 1.24 2.5 1.45 ⁄8 ⁄8-16 UNC-2B 42
60.2 84.3 31.5 63.5 36.8 9.5 19.1
UB21⁄2PA 21⁄2 2.87 3.88 1.24 3.0 1.69 1
⁄2 1
⁄2-13 UNC-2B 72
72.9 98.6 31.5 76.2 42.9 12.7 32.7
Framing

1 1
UB3PA 3 3.50 4.50 1.24 3.3 2.00 ⁄2 ⁄2-13 UNC-2B 84
System

88.9 114.3 31.5 83.8 50.8 12.7 38.1


UB31⁄2PA 31⁄2 4.00 5.00 1.24 3.7 2.25 1
⁄2 1
⁄2-13 UNC-2B 93
13⁄16"

101.6 127.0 31.5 94.0 57.2 12.7 42.2


1 1
UB4PA 4 4.50 5.50 1.24 3.9 2.5 ⁄2 ⁄2-13 UNC-2B 102
114.3 139.7 31.5 99.1 63.5 12.7 46.3
Fiberglass

1 1
System

UB5PA 5 5.56 6.59 1.24 4.5 3.03 ⁄2 ⁄2-13 UNC-2B 123


141.2 167.4 31.5 114.3 77.0 12.7 55.8
5 5
UB6PA 6 6.62 7.81 1.44 5.4 3.56 ⁄8 ⁄8-11 UNC-2B 123
168.1 198.4 36.6 137.2 90.4 15.9 55.8
5 5
UB8PA 8 8.62 9.84 1.44 6.4 4.56 ⁄8 ⁄8-11 UNC-2B 243
Special
Metals

218.9 249.9 36.6 162.6 115.8 15.9 110.2


3 3
UB10PA 10 10.75 12.25 1.65 7.7 5.68 ⁄4 ⁄4-10 UNC-2B 492
273.1 311.2 41.9 195.6 144.3 19.1 223.2
3 3
UB12PA 12 12.75 14.25 1.65 8.7 6.68 ⁄4 ⁄4-10 UNC-2B 563
323.9 362.0 41.9 221.0 169.7 19.1 255.4
PrimeAngle
System
Product
Index

156 Pipe/Conduit Supports


Pipe & Tubing Clamps

CG-10 thru CG-40 CUSH–A–GRIP®

Channel
15⁄8"
O.D. Nominal PullOut Slip
17⁄16" Part Tube Sizes Pipe Sizes Diameters Load Load
D (36.5) Number In(mm) In(mm) In(mm) Lbs(kg) Lbs(kg)
1 3 1 1
CG-10 ⁄4 ⁄8 ⁄2 ⁄4 0.25 - 0.54 500 40

Telestrut
System
C 6.4 9.5 12.7 6.4 6.4 - 13.7 226.8 18.1
5 3 7 3 1
CG-20 ⁄8 ⁄4 ⁄8 ⁄8 ⁄2 0.62 - 0.87 500 40
15.9 19.1 22.2 9.5 12.7 15.7 - 22.1 226.8 18.1
B CG-30 7
⁄8 1 11⁄8 3
⁄4 0.87 - 1.12 500 40

Hardware
A 22.2 25.4 28.6 19.1 22.1 - 28.5 226.8 18.1

Nuts &
CG-40 1 11⁄8 11⁄4 3
⁄4 1 1.00 - 1.31 500 40
25.4 28.6 31.8 19.1 25.4 25.4 - 33.3 226.8 18.1

Nominal Dimensions Hex Head Wt/100


Part Pipe “A” “B” “C” “D” Cap Screw pcs

General
Fittings
Number Size In(mm) In(mm) In(mm) In(mm) & Lock Nut Lbs(kg)
V-Pad 1
CG-10 ⁄4 115⁄16 13⁄8 3
⁄8 3
⁄16 1
⁄4-20 x 11⁄2" 4
49.2 34.9 9.5 4.8 1.8
3
CG-20 ⁄8 23⁄8 15⁄8 7
⁄16 1
⁄4 1
⁄4-20 x 2" 6

Pipe/Conduit
Includes Cushion, V-pad, and Hardware. 60.3 41.3 11.1 6.4 2.7

Supports
1
Materials: Cushion: Thermoplastic elastomer. CG-30 ⁄2 29⁄16 113⁄16 7
⁄16 5
⁄16 1
⁄4-20 x 2" 8
Hardware: Stainless Steel with Captured Nylon Locknut 65.1 46.0 11.1 7.9 3.6
3
Temperature Rating: CG-40 ⁄4 211⁄16 115⁄16 7
⁄16 5
⁄16 1
⁄4-20 x 2" 8
-40°F to +275°F (-40°C to 135°C) 68.3 49.2 11.1 7.9 3.6

Electrical
PUX3834 thru PUX41810 CUSH–A–THERM™

Fittings
The only airtight, crush-resistant insulation clamp on the market.
• Maintains thermal barrier protection
• Prevents condensation

Concrete
Inserts
• Properly supports pipe and tube
• Absorbs vibration
Nominal 3⁄4" Wall

11⁄4" Framing
Part Hole Copper

System
Number Size Nom. I.D. O.D. IPS O.D. Length
In(mm) In(mm) In(mm) In(mm) In(mm) In(mm)
3 1 3
PUX3834 ⁄8 ID ⁄4 ⁄8 - 1.81 2.17 Nominal 1" Wall
9.5 6.4 9.5 46.0 55.1 Part Hole Copper
1 3 1 1
PUX1234 ⁄2 ID ⁄8 ⁄2 ⁄4 1.89 2.17 Number Size Nom. I.D. O.D. IPS O.D. Length
12.7 9.8 12.7 6.4 48.0 55.1 In(mm) In(mm) In(mm) In(mm) In(mm) In(mm)

⁄16" Framing
5 1 5 3
PUX5834 ⁄8 ID ⁄2 ⁄8 ⁄8 2.05 2.17 PUX5810 5
⁄8 ID 1
⁄2 5
⁄8 3
⁄8 2.54 2.17

System
15.9 12.7 15.9 9.5 52.1 55.1 15.9 12.7 15.9 9.5 64.5 55.1
3 5 3
PUX3434 ⁄4 ID ⁄8 ⁄4 - 2.22 2.17 PUX3410 3
⁄4 ID 5
⁄8 3
⁄4 - 2.82 2.17
19.1 15.9 19.1 56.4 55.1 19.1 15.9 19.1 71.6 55.1

13
7 3 7 1
PUX7834 ⁄8 ID ⁄4 ⁄8 ⁄2 2.44 2.17 PUX7810 7
⁄8 ID 3
⁄4 7
⁄8 1
⁄2 2.82 2.17
22.2 19.1 22.2 12.7 62.0 55.1 22.2 19.1 22.2 12.7 71.6 55.1

Fiberglass
PUX11834 11⁄8 ID 1 11⁄8 3
⁄4 2.76 2.17 PUX11810 11⁄8 ID 1 11⁄8 3
⁄4 3.06 2.17

System
28.6 25.4 28.6 29.1 70.1 55.1 28.6 25.4 28.6 19.1 77.7 55.1
PUX13834 13⁄8 ID 11⁄4 13⁄8 1 3.19 2.56 PUX13810 13⁄8 ID 11⁄4 13⁄8 1 3.33 2.56
34.9 31.8 34.9 25.4 81.0 65.0 34.9 31.8 34.9 25.4 84.6 65.0
PUX15834 15⁄8 ID 11⁄2 15⁄8 11⁄4 3.35 2.58 PUX15810 15⁄8 ID 11⁄2 15⁄8 11⁄4 3.65 2.56
41.3 38.1 41.3 31.8 85.1 65.5
Special

41.3 38.1 41.3 31.8 92.7 65.0


Metals

PUX21834 21⁄8 ID 2 21⁄8 - 3.86 2.56 PUX21810 21⁄8 ID 2 21⁄8 - 4.16 2.56
54.0 50.8 54.0 98.0 65.0 54.0 50.8 54.0 105.7 65.0
PUX23834 23⁄8 ID 21⁄4 23⁄8 2 4.29 2.96 PUX23810 23⁄8 ID 21⁄4 23⁄8 2 3.92 2.56
60.3 57.2 60.3 50.8 109.0 75.2 60.3 57.2 60.3 50.8 99.6 65.0
PrimeAngle

25⁄8 ID 21⁄2 25⁄8


System

PUX25834 - 4.87 2.96 PUX25810 25⁄8 ID 21⁄2 25⁄8 4.87 2.96


66.7 63.5 66.7 123.7 75.2 66.7 63.5 66.7 123.7 75.2
PUX31834 31⁄8 ID 3 31⁄8 - 5.00 3.35 PUX31810 31⁄8 ID 3 31⁄8 - 5.14 3.35
79.4 76.2 79.4 127.0 85.1 79.4 76.2 79.4 130.6 85.1
PUX35834 35⁄8 ID 31⁄2 35⁄8 - 5.94 3.94 PUX35810 35⁄8 ID 31⁄2 35⁄8 - 6.48 3.94
92.1 88.9 92.1 150.9 100.1
Product

92.1 88.9 92.1 164.6 100.1


Index

PUX41834 41⁄8 ID 4 41⁄8 31⁄2 6.14 3.94 PUX41810 41⁄8 ID 4 41⁄8 31⁄2 6.48 3.94
104.8 101.6 104.8 88.9 156.0 100.1 104.8 101.6 104.8 88.9 164.6 100.1

Pipe/Conduit Supports 157


® Pipe Hangers

J1205 thru J1280, J1205 N thru J 1280 N (Plastic Coated) "J" Conduit & Pipe Hanger
Channel
15⁄8"

Rod Size A
Listed
Telestrut
System

Hex Bolt
Size as Listed
Hardware
Nuts &

Plastic Coated
General
Fittings

("N" Suffix)

Rod
Size A
Pipe/Conduit
Supports

C
Bolt
Size F
B Hole
D
Diameter E
Electrical
Fittings

NOTE: Maximum operating Plastic Coated


temperature is 300°F (148.8°C) Hanger Rod Suspended
"T" Bolt and Nut Included
Concrete
Inserts

Wt/100 Wt/100 Pipe Load


Part pcs Part pcs Size “A” “B” “C” “D” “E” “F” Lbs
Number Lbs (kg) Number Lbs (kg) In In (mm) In (mm) In (mm) In (mm) In (mm) In (mm) Lbs (kg)
1 3
J1205 20 J1205N 21 ⁄2 ⁄8 25⁄8 1 2 13
⁄32 1
⁄4 x 21⁄4 400
11⁄4" Framing

9.1 9.5 9.5 66.7 25.4 50.8 10.3 6.4 x 57.2 181
System

3 3
J1207 21 J1207N 22 ⁄4 ⁄8 27⁄8 1 21⁄4 13
⁄32 1
⁄4 x 21⁄4 400
9.5 10.0 9.5 73.0 25.4 57.2 10.3 6.4 x 57.2 181
3
J1210 24 J1210N* 25 1 ⁄8 3 1 23⁄8 13
⁄32 1
⁄4 x 21⁄2 400
10.9 11.3 9.5 76.2 25.4 60.3 10.3 6.4 x 63.5 181
J1212 27 J1212N 29 11⁄4 3
⁄8 31⁄4 1 21⁄2 13
⁄32 1
⁄4 x 23⁄4 400
Framing

12.2 13.2 9.5 82.6 25.4 63.5 10.3 6.4 x 69.9 181
System

J1215 29 J1215N* 31 11⁄2 3


⁄8 31⁄2 1 25⁄8 13
⁄32 1
⁄4 x 3 400
13.2 14.1 9.5 88.9 25.4 66.7 10.3 6.4 x 76.2 181
13⁄16"

3
J1220 33 J1220N* 35 2 ⁄8 33⁄4 11⁄8 25⁄8 13
⁄32 1
⁄4 x 31⁄2 400
15.0 15.9 9.5 95.3 28.6 66.7 10.3 6.4 x 88.9 181
J1225 71 J1225N 74 21⁄2 1
⁄2 43⁄8 11⁄8 35⁄8 9
⁄16 3
⁄8 x 41⁄2 800
Fiberglass

32.2 33.6 12.7 111.1 28.6 92.1 14.3 9.5 x 114.3 363
System

1
J1230 78 J1230N* 81 3 ⁄2 47⁄8 11⁄8 4 9
⁄16 3
⁄8 x 5 800
35.4 36.7 12.7 123.8 28.6 101.6 14.3 9.5 x 127.0 363
J1235 85 J1235N 88 31⁄2 1
⁄2 51⁄8 11⁄8 41⁄4 9
⁄16 3
⁄8 x 6 800
38.6 39.9 12.7 127.1 28.6 108.0 14.3 9.5 x 152.4 363
5
J1240 178 J1240N* 182 4 ⁄8 61⁄8 11⁄8 51⁄8 9
⁄16 3
⁄8 x 6 800
Special
Metals

80.7 82.6 15.9 155.6 28.6 130.2 14.3 9.5 x 152.4 363
5
J1250 199 J1250N 203 5 ⁄8 63⁄4 11⁄8 53⁄4 9
⁄16 3
⁄8 x 71⁄2 800
90.3 92.1 15.9 171.5 28.6 146.1 14.3 9.5 x 190.5 363
3
J1260 231 J1260N* 236 6 ⁄4 73⁄4 11⁄4 61⁄2 9
⁄16 3
⁄8 x 81⁄2 1,000
PrimeAngle

104.8 107.0 19.1 196.9 31.8 165.1 14.3 9.5 x 215.9 454
System

7
J1280 449 J1280N 458 8 ⁄8 91⁄4 11⁄4 8 9
⁄16 3
⁄8 x 10 1,200
203.7 207.7 22.2 235.0 31.8 203.2 14.3 9.5 x 254.0 544
*Standard glass drainline and glass process pipe sizes.
Minimum safety factor of five (5) on ultimate load.
Product
Index

158 Pipe/Conduit Supports


Pipe Rollers

P2474 Pipe Roller for 1⁄2" - 4" Pipe

Channel
15⁄8"
Wt/100 pcs: 268 Lbs (121.6 kg)

Telestrut
System
Design Load
500 Lbs (226.8 kg)

Hardware
Nuts &
General
Fittings
UL

Sold in pairs.

Pipe/Conduit
Saddle by

Supports
Requires 2 each 1⁄2" x 15⁄16" bolts and others.
1
⁄2" channel nuts per assembly.
Sold separately.
2 1 ⁄2 "
(63.5)

Electrical
Fittings
A
Cast iron rollers.

Concrete
Inserts
Chart for Dimension A

11⁄4" Framing
System
Pipe Insulation Thickness
Size No Insulation 1" 11⁄2" 2" 21⁄2" 3" 4"
In In (mm) In (mm) In (mm) In (mm) In (mm) In (mm) In (mm)
1
⁄2 61⁄2 61⁄2
165.1 165.1

⁄16" Framing
3
⁄4 61⁄2 61⁄2 65⁄8 67⁄8

System
165.1 165.1 168.3 174.6
1 61⁄2 61⁄2 65⁄8 67⁄8
165.1 165.1 168.3 174.6
11⁄4 61⁄2 61⁄2 67⁄8 71⁄8 73⁄8

13
165.1 165.1 174.6 181.0 187.3
11⁄2 61⁄2 61⁄2 67⁄8 71⁄8 73⁄8

Fiberglass
System
165.1 165.1 174.6 181.0 187.3
2 61⁄2 65⁄8 71⁄8 73⁄8 71⁄2 8
165.1 168.3 181.0 187.3 190.5 203.2
21⁄2 61⁄2 65⁄8 71⁄8 73⁄8 71⁄2 8
165.1 168.3 181.0 187.3 190.5 203.2
Special
Metals

3 61⁄2 7 71⁄2 73⁄4 77⁄8 81⁄8


165.1 177.8 190.5 196.9 200.0 206.4
31⁄2 61⁄2 7 71⁄2 73⁄4 77⁄8 81⁄8
165.1 177.8 190.5 196.9 200.0 206.4
PrimeAngle

4 65⁄8 71⁄4 75⁄8 77⁄8 8 83⁄8 9


System

168.3 184.2 193.7 200.0 203.2 212.7 228.6


Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness:1⁄4" (6.4mm)
9

Pipe/Conduit Supports 159


® Pipe Rollers

P2474-1 thru P2474-4 Pipe Roller for 1" - 8" Pipe


Channel
15⁄8"
Telestrut
System
Hardware
Nuts &
General
Fittings

Saddle by
others. 2 1 ⁄ 2"
(63.5)
Pipe/Conduit

A
Supports

• Pipe roller will fit standard saddles.


• Select proper roller from chart.
• Requires 2 each 1⁄2" x 15⁄16" bolts and 1⁄2"
channel nuts per assembly. Sold separately.
Electrical
Fittings
Concrete
Inserts

Design Load
750 Lbs (340 Kg)

Part A Wt/100 pcs


11⁄4" Framing

Number In (mm) Lbs (kg)


System

P2474-1 63⁄4 299


171.5 135.6
P2474-2 71⁄2 304
190.5 137.9
P2474-3 81⁄2 311
Framing

215.9 141.1
System

P2474-4 99⁄16 319


242.9 144.7
13⁄16"

Parts are shipped loose and are easily assembled during installation.
Chart for Roller Part Number Selection
Fiberglass
System

Pipe Size Insulation Thickness


In No Insulation 1" (25.4) 11⁄2" (38.1) 2" (50.8) 21⁄2" (63.5) 3" (76.2) 4" (101.6)
1
⁄2 P2474-1 P2474-1 P2474-1 P2474-2
3
⁄4 P2474-1 P2474-1 P2474-1 P2474-2
1 P2474-1 P2474-1 P2474-1 P2474-2
1
1 ⁄4 P2474-1 P2474-1 P2474-1 P2474-2
Special
Metals

11⁄2 P2474-1 P2474-1 P2474-2 P2474-2 P2474-2


2 P2474-1 P2474-1 P2474-2 P2474-2 P2474-2
21⁄2 P2474-1 P2474-1 P2474-2 P2474-2 P2474-2
3 P2474-1 P2474-2 P2474-2 P2474-3 P2474-3 P2474-3
PrimeAngle

31⁄2 P2474-1 P2474-2 P2474-2 P2474-3 P2474-3 P2474-3


System

4 P2474-1 P2474-2 P2474-2 P2474-3 P2474-3 P2474-3


5 P2474-2 P2474-3 P2474-3 P2474-3 P2474-3 P2474-4 P2474-4
6 P2474-2 P2474-3 P2474-3 P2474-3 P2474-3 P2474-4 P2474-4
8 P2474-2 P2474-3 P2474-4 P2474-4 P2474-4 P2474-4 P2474-4
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness:1⁄4" (6.4mm)
9

160 Pipe/Conduit Supports


Pipe Rollers

P2475 Pipe Roller for 6" - 16" Pipe

Channel
15⁄8"
Sold in pairs. Wt/100 pcs: 680 Lbs (308.4 kg)
2"
(50.8)

Telestrut
System
• Requires 2 each 1⁄2" x 15⁄16" bolts
and 1⁄2" channel nuts per assembly.
Sold separately.
Design Load

Hardware
Nuts &
1500 Lbs (680 Kg)
Chart for Dimension A
Material: Cast iron rollers. Pipe No Insulation Thickness
Size Insulation 1" 11⁄2" 2" 21⁄2" 3" 4"

General
Fittings
In In (mm) In (mm) In (mm) In (mm) In (mm) In (mm) In (mm)
6 91⁄2 101⁄4 101⁄2 103⁄4 11 113⁄8 117⁄8
241.3 260.4 266.7 273.1 279.4 288.9 301.6
8 101⁄8 * 11 113⁄8 113⁄4 12 121⁄2

Pipe/Conduit
Saddle by 257.2 279.4 288.9 298.5 304.8 317.5

Supports
others. 10 103⁄4 * 115⁄8 12 121⁄4 121⁄2 13
273.1 295.3 304.8 311.2 317.5 330.2
3" 12 111⁄4 * 121⁄8 121⁄2 123⁄4 13 131⁄2
(76.2) 3 1⁄2" 3 3⁄4" 285.8 308.0 317.5 323.9 330.2 342.9
TO 14 115⁄8 * 121⁄2 127⁄8 13 133⁄8 14
(88.9) (95.3)

Electrical
295.3 317.5 327.0 330.2 339.7 355.6

Fittings
16 121⁄8 * 13 133⁄8 137⁄8 14 141⁄2
A 308.0 330.2 339.7 352.4 355.6 368.3
(*Not used for this size)

Concrete
Inserts
P2476 Pipe Roller for 16" - 24" Pipe
Wt/100 pcs: 1046 Lbs (474.5 kg)

11⁄4" Framing
System
2" • Requires 4 each1⁄2" x 15⁄16" bolts
(50.8) and 1⁄2" channel nuts per assembly.
Sold separately.

⁄16" Framing
System
Design Load
2000 Lbs (907 kg)

13
Material: Cast iron rollers.

Fiberglass
System
Chart for Dimension A

Pipe Insulation Thickness


Size 11⁄2" 2" 21⁄2" 3" 4"
Saddle by In In (mm) In (mm) In (mm) In (mm) In (mm)
Special

others.
Metals

16 137⁄8 14 141⁄2
352.4 355.6 368.3
18 135⁄8 14 141⁄8 141⁄2 15
346.1 355.6 358.8 368.3 381.0
PrimeAngle

3" 20 141⁄8 141⁄2 143⁄4 15 151⁄2


System

(76.2) 3 1⁄4" 358.8 368.3 374.7 381.0 393.7


(82.6)
24 151⁄4 151⁄2 157⁄8 161⁄8 165⁄8
387.4 393.7 403.2 409.6 422.3
A
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness:1⁄4" (6.4mm)
9

Pipe/Conduit Supports 161


® Pipe Brackets

P2481 Pipe Support Bracket


Channel
15⁄8"

1
⁄4"
(6.4)
Telestrut
System

3 1⁄2"
(88.9)
For 1⁄2" pipe to 11⁄2" pipe.
Design Load (Channel Upright Listed)
Hardware
Nuts &

Wt/100 pcs P1000 P1100 P2000


Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg)
90 85 85 85
40.8 38.6 38.6 38.6
General
Fittings

4"
(101.6)
Pipe/Conduit
Supports

P2482 Pipe Support Bracket


3
⁄ 8"
(9.5)
Electrical
Fittings

4 3⁄8"
(111.1)
Concrete
Inserts

For 2" pipe to 3" pipe.


Design Load (Channel Upright Listed)
Wt/100 pcs P1000 P1100 P2000
Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg)
11⁄4" Framing
System

139 185 120 95


63.0 83.9 54.4 43.1
4"
(101.6)
Framing
System

P2243 Pipe Block


Wt/100 pcs: 40 Lbs (18.1 kg)
13⁄16"

For 2" (50.8) to 8" (203.2) Pipes


Fiberglass
System

Hole Size 7⁄16" (11.1)


Special
Metals

1"
(25.4)

Clamp Requires bolt and


PrimeAngle

3"
System

channel nut.
(76.2) Sold seperately
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄16" (14.3mm); Hole Spacing - From End: 13⁄16" (20.6 mm); Hole Spacing - On Center: 17⁄8" (47.6 mm); Width: 15⁄8"(41mm); Thickness:1⁄4" (6.4mm)
9

162 Pipe/Conduit Supports


Pipe Brackets

UP-BK thru UP-MPDS UniPier™

Channel
15⁄8"
13
⁄16"
(20.6)

Telestrut
System
The UniPier Rooftop support system provides a simple and
3" versatile way to support and manage pipe, tubing, conduit,
(76.2) HVAC systems, and the like. The UniPier system supports
without roof surface penetration and allows the parts to remain
off the surface

Hardware
Nuts &
P1109
P4100
8"

General
Fittings
8" (203.2)
(203.2)

Pipe/Conduit
Supports
Part UniPier Bases
Number Qty. Description
UP-BK 4 UniPier Base Only (4 Bases & Hardware)
UP-SPSS-6 HG 4 UP-BK + 4 Pcs P4100T HG @ 6" (152.4mm) Long for up to 31⁄2" (88.9mm) Pipe

Electrical
UP-SPSS-10HG 4 UP-BK + 4 Pcs P4100T HG @ 10" (254.0mm) Long for 4" to 8" (101.6 to 203.2mm)Pipe

Fittings
UP-MPDS-26HG 2 UP-BK + 2 Pcs P1000T HG @ 26" (66.0cm) Long for Trapeze
UP-MPDS-38HG 2 UP-BK + 2 Pcs P1000T HG @ 38" (96.5cm) Long for Trapeze
UP-MPDS-50HG 2 UP-BK + 2 Pcs P1000T HG @ 50" (127.0cm) Long for Trapeze
UP-MPDS-62HG 2 UP-BK + 2 Pcs P1000T HG @ 62" (157.5cm) Long for Trapeze

Concrete
Inserts
P1109
P4100 P1000

11⁄4" Framing
P2474

System
P1006

PA-138
P1000T

⁄16" Framing
System
P1109

13
Fiberglass
P1000 P1006

System
Threaded
P1326 Rod Special
Metals

P1006
PrimeAngle
System

P1000
P2484 P1109
P2484
Product
Index

P1326 P1006

Pipe/Conduit Supports 163


® Pipe & Conduit Reference Data
Nominal Centerline to Centerline (In/mm)
3
Pipe Dia. ⁄4" (19mm) 1" (25mm) 11⁄4" (32mm) 11⁄2" (38mm) 2" (51mm) 21⁄2" (64mm)
T S T F S T F S T F S T F S T F S
Channel

3
⁄4" T 43⁄4 – – – – – – – – – – – – – – – –
15⁄8"

19mm 121 – – – – – – – – – – – – – – – –
1
S 4 ⁄2 43⁄4 – – – – – – – – – – – – – – –
114 108 – – – – – – – – – – – – – – –
1" T 5 43⁄4 51⁄4 – – – – – – – – – – – – – –
Telestrut
System

25mm 127 121 133 – – – – – – – – – – – – – –


F 6 53⁄4 61⁄4 71⁄4 – – – – – – – – – – – – –
152 146 159 184 – – – – – – – – – – – – –
S 43⁄4 41⁄2 5 6 41⁄2 – – – – – – – – – – – –
121 114 127 152 114 – – – – – – – – – – – –
Hardware
Nuts &

11⁄4" T 51⁄4 5 51⁄2 61⁄2 5 51⁄2 – – – – – – – – – – –


32mm 133 127 140 165 127 140 – – – – – – – – – – –
F 61⁄4 6 61⁄2 71⁄2 61⁄4 63⁄4 73⁄4 – – – – – – – – – –
159 152 165 191 159 171 197 – – – – – – – – – –
3
S 4 ⁄4 41⁄2 5 6 41⁄2 1
5 ⁄4 1
6 ⁄4 3
4 ⁄4 – – – – – – – – –
General
Fittings

121 114 127 152 114 133 159 121 – – – – – – – – –


11⁄2" T 51⁄4 5 51⁄2 61⁄2 51⁄4 53⁄4 63⁄4 51⁄4 53⁄4 – – – – – – – –
38mm 133 127 140 165 133 146 171 133 146 – – – – – – – –
F 61⁄2 61⁄4 63⁄4 73⁄4 61⁄4 63⁄4 8 61⁄2 7 8 – – – – – – –
165 159 171 197 159 171 203 165 178 203 – – – – – – –
Pipe/Conduit

S 5 43⁄4 51⁄4 61⁄4 43⁄4 1


5 ⁄4 6 5 1
5 ⁄2 1
6 ⁄2 5 – – – – – –
Supports

127 121 133 159 121 133 152 127 140 165 127 – – – – – –
2" T 53⁄4 51⁄2 6 7 51⁄2 6 71⁄4 53⁄4 61⁄4 71⁄4 53⁄4 61⁄2 – – – – –
51mm 146 140 152 178 140 152 184 146 159 184 146 165 – – – – –
F 7 63⁄4 71⁄4 81⁄4 63⁄4 71⁄4 81⁄2 7 71⁄2 81⁄2 7 73⁄4 9 – – – –
178 171 184 210 171 184 216 178 191 216 178 197 229 – – – –
S 51⁄4 5 51⁄2 61⁄2 5 1
5 ⁄2 3
6 ⁄4 1
5 ⁄4 3
5 ⁄4 3
6 ⁄4 51⁄4 6 1
7 ⁄4 51⁄2 – – –
Electrical
Fittings

133 127 140 165 127 140 171 133 146 171 133 152 184 140 – – –
21⁄2" T 6 53⁄4 61⁄4 71⁄4 6 61⁄2 71⁄2 6 61⁄2 73⁄4 61⁄4 7 81⁄4 61⁄2 71⁄4 – –
64mm 152 146 159 184 152 165 191 152 165 197 159 178 210 165 184 – –
F 71⁄2 71⁄4 73⁄4 83⁄4 71⁄4 73⁄4 9 71⁄2 8 9 71⁄2 81⁄4 91⁄2 73⁄4 83⁄4 10 –
191 184 197 222 184 197 229 191 203 229 191 210 241 197 222 254 –
Concrete

S 51⁄2 51⁄4 53⁄4 63⁄4 51⁄4 53⁄4 7 51⁄2 6 7 51⁄2 61⁄4 71⁄2 53⁄4 3
6 ⁄4 8 6
Inserts

140 133 146 171 133 146 178 140 152 178 140 159 191 146 171 203 152
3" T 61⁄4 6 61⁄2 71⁄2 61⁄4 63⁄4 73⁄4 61⁄4 63⁄4 8 61⁄2 71⁄4 81⁄2 63⁄4 71⁄2 9 7
76mm 159 152 165 191 159 171 197 159 171 203 165 184 216 171 191 229 178
F 73⁄4 71⁄2 8 9 71⁄2 8 91⁄4 73⁄4 81⁄4 91⁄4 73⁄4 81⁄2 93⁄4 8 9 101⁄4 81⁄4
11⁄4" Framing

197 191 203 229 191 203 235 197 210 235 197 216 248 203 229 260 210
53⁄4 51⁄2 51⁄2 71⁄4 53⁄4 61⁄4 71⁄4 53⁄4 1 3
81⁄4 61⁄4
System

S 6 7 6 6 ⁄2 7 ⁄4 6 7
146 140 152 178 140 152 184 146 159 184 146 165 197 152 178 210 159
4" T 71⁄2 71⁄4 73⁄4 83⁄4 71⁄4 73⁄4 9 71⁄2 8 9 71⁄2 81⁄4 91⁄2 73⁄4 83⁄4 10 8
102mm 191 184 197 222 184 197 229 191 203 229 191 210 241 197 222 254 203
F 9 83⁄4 91⁄4 101⁄4 83⁄4 91⁄4 101⁄2 9 91⁄2 101⁄2 9 93⁄4 11 91⁄4 101⁄4 111⁄2 91⁄2
229 222 235 260 222 235 267 229 241 267 229 248 279 235 260 292 241
Framing

S 63⁄4 61⁄2 7 8 61⁄2 7 1


8 ⁄4 3
6 ⁄4 1
7 ⁄4 1
8 ⁄4 63⁄4 71⁄2 83⁄4 7 8 91⁄4 71⁄4
System

171 165 178 203 165 178 210 171 184 210 171 191 222 178 203 235 184
5" T 8 73⁄4 81⁄4 91⁄4 73⁄4 81⁄4 91⁄2 8 81⁄2 91⁄2 8 83⁄4 10 81⁄4 91⁄4 101⁄2 81⁄2
127mm 203 197 210 235 197 210 241 203 216 241 203 222 254 210 235 267 216
13⁄16"

F 91⁄2 91⁄4 93⁄4 103⁄4 91⁄4 93⁄4 11 91⁄2 10 11 91⁄2 101⁄4 111⁄2 93⁄4 103⁄4 12 10
241 235 248 273 235 248 279 241 254 279 241 260 292 248 273 305 254
S 71⁄4 7 71⁄2 81⁄4 7 71⁄2 83⁄4 71⁄4 73⁄4 83⁄4 71⁄4 8 91⁄4 71⁄2 81⁄2 93⁄4 73⁄4
Fiberglass

184 178 191 210 178 191 222 184 197 222 184 203 235 191 216 248 197
System

6" T 83⁄4 81⁄2 9 10 81⁄2 9 101⁄4 83⁄4 91⁄4 101⁄4 83⁄4 91⁄2 103⁄4 9 10 111⁄4 91⁄4
152mm 222 216 229 254 216 229 260 222 235 260 222 241 273 229 254 286 235
F 10 93⁄4 101⁄4 111⁄4 93⁄4 101⁄4 111⁄2 10 101⁄2 111⁄2 10 103⁄4 12 101⁄4 111⁄4 121⁄2 101⁄2
254 248 260 286 248 260 292 254 267 292 254 273 305 260 286 318 267
S 73⁄4 71⁄2 8 9 71⁄2 8 91⁄4 73⁄4 81⁄4 91⁄4 73⁄4 81⁄2 93⁄4 8 9 101⁄4 81⁄4
Special
Metals

197 191 203 229 191 203 235 197 210 235 197 216 248 203 229 260 210
8" T 83⁄4 91⁄2 10 11 93⁄4 101⁄2 111⁄4 93⁄4 101⁄4 111⁄2 10 103⁄4 12 101⁄2 11 121⁄2 101⁄2
203mm 222 241 254 279 248 267 286 248 260 292 254 273 305 267 279 318 267
F 111⁄4 11 111⁄2 121⁄2 11 111⁄2 123⁄4 111⁄4 113⁄4 123⁄4 111⁄4 12 131⁄4 111⁄2 121⁄2 133⁄4 113⁄4
286 279 292 318 279 292 324 286 298 324 286 305 337 292 318 349 298
PrimeAngle

10" T 111⁄4 11 111⁄2 121⁄2 11 111⁄2 123⁄4 111⁄4 113⁄4 123⁄4 111⁄4 12 131⁄4 111⁄2 121⁄2 133⁄4 113⁄4
System

254mm 286 279 292 318 279 292 324 286 298 324 286 305 337 292 318 349 298
F 121⁄2 121⁄4 123⁄4 133⁄4 121⁄4 123⁄4 14 121⁄2 13 14 121⁄2 131⁄4 141⁄2 123⁄4 133⁄4 15 13
318 311 324 349 311 324 356 318 330 356 318 337 368 324 349 381 330
12" T 121⁄4 12 121⁄2 131⁄2 12 121⁄2 133⁄4 121⁄4 123⁄4 133⁄4 121⁄4 13 141⁄4 121⁄2 131⁄2 143⁄4 123⁄4
305mm 311 305 318 343 305 318 349 311 324 349 311 330 362 318 343 375 324
Product

F 14 133⁄4 141⁄4 151⁄4 133⁄4 141⁄4 151⁄2 14 141⁄2 151⁄2 14 143⁄4 16 141⁄4 151⁄4 161⁄2 141⁄2
Index

356 349 362 387 349 362 394 356 368 394 356 375 406 362 387 419 368

164 Pipe/Conduit Supports


Pipe & Conduit Reference Data

Pipe Spacing Table

Channel
15⁄8"
This chart, developed by Julius Getlan of Seelye Stevenson Value & Knect, consulting engineers, New York City, enables one to quickly
determine the centerline-to-centerline dimension between any two size pipes on a rack.
Select the smaller pipe size at top and select the other at the side of the table. Where the appropriate columns intersect, the dimension is given.

Telestrut
System
These factors are included in the dimensions given:
• O.D. of flanges and fittings.
• 1" insulation over flanges and fittings.
• All fractional dimensions less than 1⁄4" were

Hardware
Nuts &
increased to the next larger 1⁄4".
• Clear space between fittings as follows:
1. 1" between piping 3" and smaller.
2. 11⁄2" between a pipe 3" and smaller and a pipe 4" or larger.

General
Fittings
3. 2" between piping 4" and larger.

Pipe/Conduit
Supports
Electrical
Fittings
T – denotes threaded IPS pipe. F – denotes flanged fittings on pipe. S – denotes soldered or brazed tubing.

Concrete
Inserts
Centerline to Centerline (In/mm) Nominal
3" (76mm) 4" (102mm) 5" (127mm) 6" (152mm) 8" (203mm) 10" (254mm) 12" (305mm) Pipe Dia.
T F S T F S T F S T F S T F T F T F
73⁄4 – – – – – – – – – – – – – – – – – T 3"
197 – – – – – – – – – – – – – – – – – 76mm

11⁄4" Framing
1 1
9 ⁄4 10 ⁄2 – – – – – – – – – – – – – – – – F

System
235 267 – – – – – – – – – – – – – – – –
71⁄4 81⁄2 61⁄2 – – – – – – – – – – – – – – – S
184 216 165 – – – – – – – – – – – – – – –
9 101⁄4 81⁄4 10 – – – – – – – – – – – – – – T 4"
229 260 210 254 – – – – – – – – – – – – – – 102mm
101⁄2 113⁄4 93⁄4 1
11 ⁄2 13 – – – – – – – – – – – – – F

⁄16" Framing
267 298 248 292 330 – – – – – – – – – – – – –

System
81⁄4 91⁄2 71⁄2 91⁄4 103⁄4 81⁄2 – – – – – – – – – – – – S
210 241 191 235 273 216 – – – – – – – – – – – –
91⁄2 103⁄4 83⁄4 101⁄4 12 93⁄4 11 – – – – – – – – – – – T 5"

13
241 273 222 260 305 248 279 – – – – – – – – – – – 127mm
11 121⁄4 101⁄4 12 131⁄2 111⁄4 1
12 ⁄2 14 – – – – – – – – – – F
279 311 260 305 343 286 318 356 – – – – – – – – – –

Fiberglass
System
83⁄4 10 8 93⁄4 111⁄4 9 101⁄4 113⁄4 91⁄2 – – – – – – – – – S
222 254 203 248 286 229 260 298 241 – – – – – – – – –
101⁄4 111⁄2 91⁄2 111⁄4 123⁄4 101⁄2 113⁄4 131⁄4 11 121⁄2 – – – – – – – – T 6"
260 292 241 286 324 267 298 337 279 318 – – – – – – – – 152mm
111⁄2 121⁄4 103⁄4 121⁄2 14 113⁄4 13 1 1
14 ⁄2 12 ⁄4 13 ⁄41
15 – – – – – – – F
292 311 273 318 356 298 330 368 311 337 381 – – – – – – –
Special
Metals

91⁄4 101⁄2 81⁄2 101⁄4 113⁄4 91⁄2 103⁄4 121⁄4 10 111⁄2 123⁄4 101⁄2 – – – – – – S
235 267 216 260 298 241 273 311 254 292 324 267 – – – – – –
111⁄4 123⁄4 103⁄4 121⁄2 14 113⁄4 13 141⁄2 121⁄4 133⁄4 15 123⁄4 143⁄4 – – – – – T 8"
286 324 273 318 356 298 330 368 311 349 381 324 375 – – – – – 203mm
PrimeAngle

123⁄4 14 12 133⁄4 151⁄4 13 1 3


14 ⁄4 15 ⁄4 13 ⁄21
15 1
16 ⁄4 14 1
16 ⁄4 17 .5 – – – – F
System

324 356 305 349 387 330 362 400 343 381 413 356 413 17 .5 – – – –
123⁄4 14 12 133⁄4 151⁄4 13 141⁄4 153⁄4 131⁄2 15 161⁄4 14 161⁄4 171⁄2 171⁄2 – – – T 10"
324 356 305 349 387 330 362 400 343 381 413 356 413 445 445 – – – 254mm
14 151⁄4 131⁄4 15 161⁄2 141⁄4 151⁄2 17 143⁄4 161⁄4 171⁄2 151⁄4 171⁄2 183⁄4 183⁄4 20 – – F
356 387 337 381 419 362 394 432 375 413 445 387 445 476 476 508 – –
133⁄4 15 13 143⁄4 161⁄4 14 151⁄4 163⁄4 141⁄2 16 171⁄4 15 171⁄4 181⁄2 181⁄2 193⁄4 191⁄2 – T 12"
Product
Index

349 381 330 375 413 356 387 425 368 406 438 381 438 470 470 502 495 – 305mm
151⁄2 163⁄4 143⁄4 161⁄2 18 153⁄4 17 181⁄4 161⁄4 173⁄4 19 163⁄4 14 201⁄4 201⁄4 211⁄2 211⁄4 29 F
394 425 375 419 457 400 432 464 413 451 483 425 356 514 514 546 540 737

Pipe/Conduit Supports 165


® Pipe & Conduit Reference Data

Channel Selection for Schedule 10 Sprinkler Pipe Trapeze Hangers


Channel
15⁄8"

Note: Based on NFPA-13-1996 Section Modulus Table 3-10.1.7(a). Each of the SCHEDULE 10 PIPE
following tables indicate the allowable span of the trapeeze and the nominal Nominal Wall Pipe Water Total
pipe size for the specified channel . An entry of “–” indicates that the channel Pipe Dia. O.D. Thickness I. D. Weight Weight Weight
cannot be used for this span/pipe size combination. The table is based on a (in) (in) (in) (in) (p/f) (p/f) (p/f)
Telestrut
System

maximum allowable bending stress of 15 KSI and a midspan concentrated 1 1.315 0.109 1.097 1.41 0.42 1.83
load from 15 ft of water-filled pipe, plus 250 lb. 11⁄4 1.660 0.109 1.442 1.81 0.73 2.54
Unistrut Section 11⁄2 1.900 0.109 1.682 2.09 0.99 3.08
Unistrut Section
Channel Modulus 2 2.375 0.109 2.157 2.64 1.63 4.28
Channel Modulus
21⁄2 2.875 0.120 2.635 3.53 2.44 5.97
Hardware

in3 (cm3) in3 (cm3)


Nuts &

3 3.500 0.120 3.260 4.34 3.73 8.07


P3000 0.154 P3001 0.431
31⁄2 4.000 0.120 3.760 4.98 4.97 9.95
2.52 7.06
4 4.500 0.120 4.260 5.62 6.38 12.00
P1000 0.202 P1001 0.572
9.37 5 5.563 0.134 5.295 7.78 9.85 17.63
3.31
6 6.625 0.134 6.357 9.30 14.20 23.50
General

P5501 1.153
Fittings

P5500 0.391
6.41 18.89 8 8.625 0.188 8.249 16.96 23.91 40.87
P5000 0.628 P5001 1.916 10 10.750 0.188 10.374 21.23 37.82 59.04
10.29 31.40
Pipe/Conduit

NFPA 13 REQUIRED TRAPEZE SECTION MODULUS FOR SCH 10 PIPE


Supports

Trapeze Pipe Diameter


1 1
Span 1" 1 ⁄4" 1 ⁄2" 2" 21⁄2" 3" 31⁄2" 4" 5" 6" 8" 10"
1' - 6" 0.08 0.09 0.09 0.09 0.10 0.11 0.12 0.13 0.15 0.18 0.24 0.32
2' - 0" 0.11 0.12 0.12 0.13 0.13 0.15 0.16 0.17 0.20 0.24 0.32 0.43
2' - 6" 0.14 0.14 0.15 0.16 0.17 0.18 0.20 0.21 0.25 0.30 0.40 0.54
3' - 0" 0.17 0.17 0.18 0.19 0.20 0.22 0.24 0.26 0.31 0.36 0.48 0.65
Electrical
Fittings

4' - 0" 0.22 0.23 0.24 0.25 0.27 0.29 0.32 0.34 0.41 0.48 0.64 0.87
5' - 0" 0.28 0.29 0.30 0.31 0.34 0.37 0.40 0.43 0.51 0.59 0.80 1.08
6' - 0" 0.33 0.35 0.36 0.38 0.41 0.44 0.48 0.51 0.61 0.71 0.97 1.30
7' - 0" 0.39 0.40 0.41 0.44 0.47 0.52 0.55 0.60 0.71 0.83 1.13 1.52
8' - 0" 0.44 0.46 0.47 0.50 0.54 0.59 0.63 0.68 0.81 0.95 1.29 1.73
Concrete
Inserts

9' - 0" 0.50 0.52 0.53 0.56 0.61 0.66 0.71 0.77 0.92 1.07 1.45 1.95
10' - 0" 0.56 0.58 0.59 0.63 0.68 0.74 0.79 0.85 1.02 1.19 1.61 2.17

Values taken from NFPA 13 (1994 Edition), Table 2-6.1.5(a)


11⁄4" Framing

SINGLE CHANNEL TRAPEZE FOR SCH 10 PIPE


System

Trapeze Pipe Diameter


Span 1" 11⁄4" 11⁄2" 2" 21⁄2" 3" 31⁄2" 4" 5" 6" 8" 10"
1' - 6" P3000 P3000 P3000 P3000 P3000 P3000 P3000 P3000 P3000 P1000 P5500 P5500
2' - 0" P3000 P3000 P3000 P3000 P3000 P3000 P1000 P1000 P1000 P5500 P5500 P5000
2' - 6" P3000 P3000 P3000 P1000 P1000 P1000 P1000 P5500 P5500 P5500 P5000 P5000
Framing

3' - 0" P1000 P1000 P1000 P1000 P1000 P5500 P5500 P5500 P5500 P5500 P5000 N/A
System

4' - 0" P5500 P5500 P5500 P5500 P5500 P5500 P5500 P5500 P5000 P5000 N/A N/A
5' - 0" P5500 P5500 P5500 P5500 P5500 P5500 P5000 P5000 P5000 P5000 N/A N/A
13⁄16"

6' - 0" P5500 P5500 P5500 P5500 P5000 P5000 P5000 P5000 P5000 N/A N/A N/A
7' - 0" P5500 P5000 P5000 P5000 P5000 P5000 P5000 P5000 N/A N/A N/A N/A
8' - 0" P5000 P5000 P5000 P5000 P5000 P5000 N/A N/A N/A N/A N/A N/A
9' - 0" P5000 P5000 P5000 P5000 P5000 N/A N/A N/A N/A N/A N/A N/A
Fiberglass
System

10' - 0" P5000 P5000 P5000 N/A N/A N/A N/A N/A N/A N/A N/A N/A

DOUBLE CHANNEL TRAPEZE FOR SCH 10 PIPE


Trapeze Pipe Diameter
Special

11⁄4" 11⁄2" 21⁄2" 31⁄2"


Metals

Span 1" 2" 3" 4" 5" 6" 8" 10"


1' - 6" P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001
2' - 0" P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001
2' - 6" P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P1001
PrimeAngle

3' - 0" P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P1001 P5501
System

4' - 0" P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P1001 P5501 P5501
5' - 0" P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P1001 P5501 P5501 P5501
6' - 0" P3001 P3001 P3001 P3001 P3001 P1001 P1001 P1001 P5501 P5501 P5501 P5001
7' - 0" P3001 P3001 P3001 P1001 P1001 P1001 P1001 P5501 P5501 P5501 P5501 P5001
8' - 0" P1001 P1001 P1001 P1001 P1001 P5501 P5501 P5501 P5501 P5501 P5001 N/A
Product

9' - 0" P1001 P1001 P1001 P1001 P5501 P5501 P5501 P5501 P5501 P5501 P5001 N/A
Index

10' - 0" P1001 P5501 P5501 P5501 P5501 P5501 P5501 P5501 P5501 P5001 P5001 N/A

166 Pipe/Conduit Supports


Pipe & Conduit Reference Data

Channel Selection for Schedule 40 Sprinkler Pipe Trapeze Hangers

Channel
15⁄8"
Note: Based on NFPA-13-1996 Section Modulus Table 3-10.1.7(a). Each of the SCHEDULE 40 PIPE
following tables indicate the allowable span of the trapeeze and the nominal Nominal Wall Pipe Water Total
pipe size for the specified channel . An entry of “–” indicates that the channel Pipe Dia. O.D. Thickness I. D. Weight Weight Weight
cannot be used for this span/pipe size combination. The table is based on a (in) (in) (in) (in) (p/f) (p/f) (p/f)

Telestrut
System
maximum allowable bending stress of 15 KSI and a midspan concentrated 1 1.315 0.133 1.049 1.68 0.39 2.07
load from 15 ft of water-filled pipe, plus 250 lb. 11⁄4 1.660 0.140 1.380 2.27 0.67 2.94
Unistrut Section Unistrut Section 11⁄2 1.900 0.145 1.610 2.72 0.91 3.63
Channel Modulus Channel Modulus 2 2.375 0.154 2.067 3.66 1.50 5.16
in3 (cm3) in3 (cm3) 21⁄2 2.875 0.203 2.469 5.80 2.14 7.94

Hardware
Nuts &
P3001 0.431 3 3.500 0.216 3.068 7.58 3.31 10.89
P3000 0.154
2.52 7.06 31⁄2 4.000 0.226 3.548 9.12 4.42 13.54
P1000 0.202 P1001 0.572 4 4.500 0.237 4.026 10.80 5.70 16.50
3.31 9.37 5 5.563 0.258 5.047 14.63 8.95 23.58
P5500 0.391 P5501 1.153 6 6.625 0.280 6.065 18.99 12.93 31.92

General
Fittings
6.41 18.89 8 8.625 0.322 7.981 28.58 22.38 50.96
P5000 0.628 P5001 1.916 10 10.750 0.365 10.020 40.52 35.28 75.80
10.29 31.40

Pipe/Conduit
NFPA 13 REQUIRED TRAPEZE SECTION MODULUS FOR SCH 40 PIPE

Supports
Trapeze Pipe Diameter
Span 1" 11⁄4" 11⁄2" 2" 21⁄2" 3" 31⁄2" 4" 5" 6" 8" 10"
1' - 6" 0.08 0.09 0.09 0.10 0.11 0.12 0.13 0.15 0.18 0.22 0.30 0.41
2' - 0" 0.11 0.12 0.12 0.13 0.15 0.16 0.18 0.20 0.24 0.29 0.40 0.55
2' - 6" 0.14 0.15 0.15 0.16 0.18 0.21 0.22 0.25 0.30 0.36 0.50 0.68

Electrical
3' - 0" 0.17 0.18 0.18 0.20 0.22 0.25 0.27 0.30 0.36 0.43 0.60 0.82

Fittings
4' - 0" 0.22 0.24 0.24 0.26 0.29 0.33 0.36 0.40 0.48 0.58 0.80 1.09
5' - 0" 0.28 0.29 0.30 0.33 0.37 0.41 0.45 0.49 0.60 0.72 1.00 1.37
6' - 0" 0.34 0.35 0.36 0.39 0.44 0.49 0.54 0.59 0.72 0.87 1.20 1.64
7' - 0" 0.39 0.41 0.43 0.46 0.51 0.58 0.63 0.69 0.84 1.01 1.41 1.92

Concrete
8' - 0" 0.45 0.47 0.49 0.52 0.59 0.66 0.72 0.79 0.96 1.16 1.61 2.19

Inserts
9' - 0" 0.50 0.53 0.55 0.59 0.66 0.74 0.81 0.89 1.08 1.30 1.81 2.46
10' - 0" 0.56 0.59 0.61 0.65 0.74 0.82 0.90 0.99 1.20 1.44 2.01 2.74

Values taken from NFPA 13 (1994 Edition), Table 2-6.1.5(a)

11⁄4" Framing
SINGLE CHANNEL TRAPEZE FOR SCH 40 PIPE

System
Trapeze Pipe Diameter
Span 1" 11⁄4" 11⁄2" 2" 21⁄2" 3" 31⁄2" 4" 5" 6" 8" 10"
1' - 6" P3000 P3000 P3000 P3000 P3000 P3000 P3000 P3000 P1000 P5500 P5500 P5000
2' - 0" P3000 P3000 P3000 P3000 P3000 P1000 P1000 P1000 P5500 P5500 P5000 P5000
2' - 6" P3000 P3000 P3000 P1000 P1000 P5500 P5500 P5500 P5500 P5500 P5000 N/A

⁄16" Framing
3' - 0" P1000 P1000 P1000 P1000 P5500 P5500 P5500 P5500 P5500 P5000 P5000 N/A

System
4' - 0" P5500 P5500 P5500 P5500 P5500 P5500 P5500 P5000 P5000 P5000 N/A N/A
5' - 0" P5500 P5500 P5500 P5500 P5500 P5000 P5000 P5000 P5000 N/A N/A N/A
6' - 0" P5500 P5500 P5500 P5500 P5000 P5000 P5000 P5000 N/A N/A N/A N/A
7' - 0" P5500 P5000 P5000 P5000 P5000 P5000 N/A N/A N/A N/A N/A N/A

13
8' - 0" P5000 P5000 P5000 P5000 P5000 N/A N/A N/A N/A N/A N/A N/A
9' - 0" P5000 P5000 P5000 P5000 N/A N/A N/A N/A N/A N/A N/A N/A

Fiberglass
System
10' - 0" P5000 P5000 P5000 N/A N/A N/A N/A N/A N/A N/A N/A N/A

DOUBLE CHANNEL TRAPEZE FOR SCH 40 PIPE


Trapeze Pipe Diameter
Special

11⁄4" 11⁄2" 21⁄2" 31⁄2"


Metals
Span 1" 2" 3" 4" 5" 6" 8" 10"
1' - 6" P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001
2' - 0" P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P1001
2' - 6" P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P1001 P5501
PrimeAngle

3' - 0" P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P5501 P5501
System

4' - 0" P3001 P3001 P3001 P3001 P3001 P3001 P3001 P3001 P1001 P5501 P5501 P5501
5' - 0" P3001 P3001 P3001 P3001 P3001 P3001 P1001 P1001 P5501 P5501 P5501 P5001
6' - 0" P3001 P3001 P3001 P3001 P1001 P1001 P1001 P5501 P5501 P5501 P5001 P5001
7' - 0" P3001 P3001 P3001 P1001 P1001 P5501 P5501 P5501 P5501 P5501 P5001 N/A
8' - 0" P1001 P1001 P1001 P1001 P5501 P5501 P5501 P5501 P5501 P5001 P5001 N/A
Product

9' - 0" P1001 P1001 P1001 P5501 P5501 P5501 P5501 P5501 P5501 P5001 N/A N/A
Index

10' - 0" P1001 P5501 P5501 P5501 P5501 P5501 P5501 P5501 P5001 P5001 N/A N/A

Pipe/Conduit Supports 167


® Pipe & Conduit Reference Data

Electrical Metallic Tubing (EMT) - Thin Wall Intermediate Metallic Conduit (IMC)
Channel
15⁄8"

Tubing Size Outside Inside Weight Conduit Weight of


(Nominal) Diameter Diameter Of Tubing Size Outside Inside Weight Conduit and
In In (mm) In (mm) Lbs/Ft (kg/m) (Nominal) Diameter Diameter Of Conduit Conductor
In In (mm) In (mm) Lbs/Ft (kg/m) Lbs/Ft (kg/m)
Telestrut

3
⁄8 0.577 0.497 0.23
System

1
14.7 12.6 0.34 ⁄2 0.815 0.745 0.60 0.12
1
⁄2 0.706 0.626 0.29 20.7 18.9 0.89 0.18
3
17.9 15.9 0.43 ⁄4 1.029 0.954 0.82 1.13
3
⁄4 0.922 0.830 0.44 26.1 24.2 1.22 1.68
Hardware

23.4 21.1 0.65 1 1.290 1.205 1.16 1.82


Nuts &

1 1.163 1.055 0.64 32.8 30.6 1.73 2.71


29.5 26.8 0.95 11⁄4 1.638 1.553 1.50 2.67
11⁄4 1.510 1.388 0.95 41.6 39.4 2.23 3.97
38.4 35.3 1.41 11⁄2 1.883 1.793 1.82 3.42
General
Fittings

11⁄2 1.740 1.618 1.10 47.8 45.5 2.71 5.09


44.2 41.1 1.64
2 2.360 2.266 2.42 5.04
2 2.197 2.075 1.40 59.9 57.6 3.60 7.50
55.8 52.7 2.08
21⁄2 2.857 2.727 4.01 7.75
21⁄2 2.875 2.731 2.30
72.6 69.3 5.97 11.53
Pipe/Conduit

73.0 69.4 3.42


Supports

3 3.476 3.346 4.43 10.69


3 3.500 3.356 2.70
88.9 85.2 4.02 88.3 85.0 6.59 15.91
31⁄2 4.000 3.834 3.40 31⁄2 3.971 3.841 5.73 13.46
101.6 97.4 5.06 100.9 97.6 8.53 20.03
4 4.500 4.334 4.00 4 4.466 4.336 6.38 16.37
113.4 110.1 9.49 24.36
Electrical

114.3 110.1 5.95


Fittings

Copper Tube (Type L) Copper Tube (Type K)


Nom. Tube O.D. Tubing O.D. Wall Thick. Wt./Ft. Wt. Water/Ft Nom. Tube O.D. Tubing O.D. Wall Thick. Wt./Ft. Wt. Water/Ft
Concrete

Size In (mm) In (mm) In (mm) Lbs (kg) Lbs (kg) Size In (mm) In (mm) In (mm) Lbs (kg) Lbs (kg)
Inserts

1 3 1 3
⁄4" ⁄8 0.375 0.030 0.126 0.034 ⁄4" ⁄8 0.375 0.035 0.145 0.032
10 9.5 0.8 3.2 0.9 10 9.53 0.89 3.68 0.81
3 1 3 1
⁄8" ⁄2 0.500 0.035 0.198 0.062 ⁄8" ⁄2 0.500 0.005 0.269 0.055
13 12.7 0.9 5.0 1.6 13 12.70 0.13 6.83 1.40
11⁄4" Framing

1 5 1 5
⁄2" ⁄8 0.625 0.040 0.285 0.100 ⁄2" ⁄8 0.625 0.049 0.344 0.094
System

16 15.9 1.0 7.2 2.5 16 15.88 1.24 8.74 2.39


5 3 5 3
⁄8" ⁄4 0.750 0.042 0.362 0.151 ⁄8" ⁄4 0.750 0.049 0.418 0.144
19 19.1 1.1 9.2 3.8 19 19.05 1.24 10.62 3.66
3 7 3 7
⁄4" ⁄8 0.875 0.045 0.455 0.209 ⁄4" ⁄8 0.875 0.065 0.641 0.188
22 22.2 1.1 11.6 5.3 22 22.23 1.65 16.28 4.78
1" 11⁄8 1.125 0.050 0.655 0.357 1" 11⁄8 1.125 0.065 0.839 0.337
Framing

29 28.6 1.3 16.6 9.1 29 28.58 1.65 21.31 8.56


System

11⁄4" 13⁄8 1.375 0.055 0.884 0.546 11⁄4" 13⁄8 1.375 0.065 1.040 0.527
35 34.9 1.4 22.5 13.9 35 34.93 1.65 26.42 13.39
13⁄16"

11⁄2" 15⁄8 1.625 0.060 1.140 0.767 11⁄2" 15⁄8 1.625 0.072 1.360 0.743
41 41.3 1.5 29.0 19.5 41 41.28 1.83 34.54 18.87
2" 21⁄8 2.125 0.070 1.750 1.341 2" 21⁄8 2.125 0.083 2.060 1.310
54 54.0 1.8 44.5 34.1 54 53.98 2.11 52.32 33.27
Fiberglass
System

21⁄2" 25⁄8 2.625 0.080 2.480 2.064 21⁄2" 25⁄8 2.625 0.095 2.920 2.000
67 66.7 2.0 63.0 52.4 67 66.68 2.41 74.17 50.80
3" 31⁄8 3.125 0.090 3.330 2.949 3" 31⁄8 3.125 0.109 4.000 2.960
79 79.4 2.3 84.6 74.9 79 79.38 2.77 101.60 75.18
31⁄2" 35⁄8 3.625 0.100 4.290 3.989 31⁄2" 35⁄8 3.625 0.120 5.120 3.900
Special
Metals

92 92.1 2.5 109.0 101.3 92 92.08 3.05 130.05 99.06


4" 41⁄8 4.125 0.110 5.380 5.188 4" 41⁄8 4.125 0.134 6.510 5.060
105 104.8 2.8 136.7 131.8 105 104.78 3.40 165.35 128.52
5" 51⁄8 5.125 0.125 7.610 8.081 5" 51⁄8 5.125 0.160 9.670 8.000
130 130.2 3.2 193.3 205.3 130 130.18 4.06 245.62 203.20
PrimeAngle
System

6" 61⁄8 6.125 0.140 10.200 11.616 6" 61⁄8 6.125 0.192 13.870 11.200
156 155.6 3.6 259.1 295.0 156 155.58 4.88 352.30 284.48
8" 81⁄8 8.125 0.200 19.290 20.289 8" 81⁄8 8.125 0.271 25.900 19.500
206 206.4 5.1 490.0 515.3 206 206.38 6.88 657.86 495.30
10" 101⁄8 10.125 0.250 30.100 31.590 10" 101⁄8 10.125 0.338 40.300 30.423
257 257.2 6.4 764.5 802.4 257 257.18 8.59 1,023.62 772.74
Product
Index

12" 121⁄8 12.125 0.280 40.400 45.426 12" 121⁄8 12.125 0.405 57.800 43.675
308 308.0 7.1 1,026.2 1,153.8 308 307.98 10.29 1,468.12 1,109.35

168 Pipe/Conduit Supports


Pipe & Conduit Reference Data

Rigid Steel (Heavy Duty) Conduit

Channel
15⁄8"
Maximum Weight* Nominal Max. Nominal Max.
Conduit Of Conduit Pipe Size Span Pipe Size Span
Size I. D. Of O. D. Of O. D. Of Weight of And Conductor Not Lead In Ft (m) In Ft (m)
(Nominal) Conduit Conduit Coupling Conduit Lead Covered Covered

Telestrut
1 7 8 19

System
In In (mm) In (mm) In (mm) Lbs/Ft (kg/m) Lbs/Ft (kg/m) Lbs/Ft (kg/m)
1 2.13 5.79
⁄2 0.622 0.840 1.063 0.85 1.20 1.00
15.8 21.3 27.0 1.26 1.79 1.49 11⁄2 9 10 22
3
⁄4 0.824 1.050 1.297 1.13 1.80 1.40
2.74 6.71
20.9 26.7 32.9 1.68 2.68 2.08 2 10 12 23

Hardware
3.05 7.01

Nuts &
1 1.049 1.315 1.563 1.68 2.60 2.30
26.6 33.4 39.7 2.50 3.87 3.42 21⁄2 11 14 25
11⁄4 1.380 1.660 1.969 2.28 4.30 3.60 3.35 7.62
35.1 42.2 50.0 3.39 6.40 5.36 3 12 16 27
11⁄2 1.610 1.900 2.234 2.73 5.90 4.50 3.66 8.23

General
Fittings
40.9 48.3 56.7 4.06 8.78 6.70 31⁄2 13 18 28
2 2.067 2.375 2.719 3.68 8.50 7.20 3.96 8.53
52.5 60.3 69.1 5.48 12.65 10.71 4 14 20 30
21⁄2 2.469 2.875 3.313 5.82 11.50 10.20 4.27 9.14
62.7 73.0 84.2 8.66 17.11 15.18

Pipe/Conduit
5 16 24 32

Supports
3 3.068 3.500 3.938 7.62 16.50 14.50 4.88 9.75
77.9 88.9 100.0 11.34 24.55 21.58
31⁄2 3.548 4.000 4.438 9.20 19.00 17.50 The above spacing based on a combined
90.1 101.6 112.7 13.69 28.28 26.04 bending and shear stress of 1500 PSI
4 4.026 4.500 4.938 10.89 24.80 21.50 when pipe is filled with water and the
102.3 114.3 125.4 16.21 36.91 32.00 pitch of the line is such that a sag of 0.1

Electrical
Fittings
5 5.047 5.563 6.296 14.81 35.90 30.80 in. between supports is permissible.
128.2 141.3 159.9 22.04 53.43 45.84
6 6.065 6.625 7.358 19.19 50.70 43.40
154.1 168.3 186.9 28.56 75.45 64.59

Concrete
* Maximum weight equals weight of rigid conduit plus weight of heaviest conductor

Inserts
combination (from the National Electrical Code Handbook.)

Conduit Supports Schedule 40: PVC Plastic Pipe

11⁄4" Framing
346-12. Supports. Rigid metal conduit shall be installed Pipe Size Outside Inside Pipe Pipe and Water

System
(Nominal) Diameter Diameter Weight Weight
as a complete system as provided in Article 300 and In In(mm) In (mm) Lbs/Ft (kg/m) Lbs/Ft (kg/m)
shall be securely fastened in place. Conduit shall be 1
⁄4 0.540 0.354 0.081 0.12
firmly fastened within 3 feet (914 mm) of each outlet 13.7 9.0 0.12 0.18
box, junction box, cabinet, or fitting. Conduit shall be 3
⁄8 0.675 0.483 0.109 0.19

⁄16" Framing
supported at least every 10 feet (3.05 m). 17.1 12.3 0.16 0.28

System
1
⁄2 0.840 0.608 0.161 0.29
Exception: If made up with threaded couplings, it shall 21.3 15.4 0.24 0.43
3
be permissible to support straight runs of rigid metal ⁄4 1.050 0.810 0.214 0.44

13
26.7 20.6 0.32 0.65
conduit in accordance with Table 346-12, provided such
1 1.315 1.033 0.315 0.68
supports prevent transmission of stresses to termination 33.4 26.2 0.47 1.01

Fiberglass
System
where conduit is deflected between supports. 11⁄4 1.660 1.364 0.426 1.06
42.2 34.6 0.63 1.58
Table 346-12 11⁄2 1.900 1.592 0.509 1.37
Support for Rigid Metal Conduit 48.3 40.4 0.76 2.04
Maximum Distance 2 2.375 2.049 0.682 2.11
Special
Metals

Conduit Size Between Supports 60.3 52.0 1.01 3.14


In (mm) Ft (m) 21⁄2 2.875 2.445 1.076 3.11
1 3 73.0 62.1 1.60 4.63
⁄2- ⁄4 10
12.7 - 19.1 3.05 3 3.500 3.042 1.409 4.55
88.9 77.3 2.10 6.77
PrimeAngle

1 12
System

4 4.500 3.998 2.006 7.44


25.4 3.66
114.3 101.5 2.99 11.07
11⁄4- 11⁄2 14
6 6.625 6.031 3.535 15.90
31.8 - 38.1 4.27 168.3 153.2 5.26 23.66
2- 21⁄2 16 8 8.625 7.943 5.305 26.75
50.8 - 63.5 4.88 219.1 201.8 7.89 39.81
Product
Index

3 & larger 20 10 10.750 9.976 7.532 41.35


76.2 - Larger 6.10 273.1 253.4 11.21 61.54

Pipe/Conduit Supports 169


® Pipe & Conduit Reference Data

Data for Schedule Steel Pipe


Channel
15⁄8"

Nom. Pipe Outside Inside Pipe Pipe and Water Nom. Pipe Outside Inside Pipe Pipe and Water
Size Schedule Dia. Dia. Weight Weight Size Schedule Dia. Dia. Weight Weight
In In(mm) In (mm) Lbs/Ft (kg/m) Lbs/Ft (kg/m) In In(mm) In (mm) Lbs/Ft (kg/m) Lbs/Ft (kg/m)
1
Telestrut

⁄8 40 0.405 0.269 0.24 0.27 4 40 4.500 4.026 10.78 16.30


System

10.3 6.8 0.11 0.12 114.3 102.3 4.89 7.39


80 0.405 0.215 0.31 0.33 80 4.500 3.826 14.97 19.95
10.3 5.5 0.14 0.15 114.3 97.2 6.79 9.05
1
⁄4 40 0.540 0.364 0.42 0.47 120 4.500 3.624 18.98 23.45
Hardware

13.7 9.2 0.19 0.21 114.3 92.0 8.61 10.64


Nuts &

80 0.540 0.302 0.53 0.57 160 4.500 3.438 22.48 26.51


13.7 7.7 0.24 0.26 114.3 87.3 10.20 12.02
3
⁄8 40 0.675 0.493 0.57 0.65 5 40 5.563 5.047 14.60 23.27
17.1 12.5 0.26 0.29 141.3 128.2 6.62 10.56
80 0.675 0.423 0.74 0.80 80 5.563 4.813 20.75 28.64
General
Fittings

17.1 10.7 0.33 0.36 141.3 122.2 9.41 12.99


1
⁄2 40 0.840 0.622 0.85 0.98 120 5.563 4.563 27.01 34.09
21.3 15.8 0.39 0.45 141.3 115.9 12.25 15.46
80 0.840 0.546 1.09 1.19 160 5.563 4.313 32.92 39.26
Pipe/Conduit

21.3 13.9 0.49 0.54 141.3 109.5 14.93 17.81


Supports

160 0.840 0.464 1.31 1.38 6 40 6.625 6.065 18.95 31.48


21.3 11.8 0.59 0.63 168.3 154.1 8.60 14.28
3
⁄4 40 1.050 0.824 1.13 1.36 80 6.625 5.761 28.54 39.84
26.7 20.9 0.51 0.62 168.3 146.3 12.95 18.07
80 1.050 0.742 1.47 1.66 120 6.625 5.501 36.35 46.66
26.7 18.8 0.67 0.75 168.3 139.7 16.49 21.16
Electrical
Fittings

160 1.050 0.612 1.94 2.07 160 6.625 5.187 45.30 54.47
26.7 15.5 0.88 0.94 168.3 131.7 20.55 24.71
1 40 1.315 1.049 1.68 2.05 8 20 8.625 8.125 22.34 44.82
33.4 26.6 0.76 0.93 219.1 206.4 10.13 20.33
80 1.315 0.957 2.17 2.48 30 8.625 8.071 24.67 46.85
Concrete
Inserts

33.4 24.3 0.98 1.13 219.1 205.0 11.19 21.25


160 1.315 0.815 2.84 3.07 40 8.625 7.981 28.52 50.21
33.4 20.7 1.29 1.39 219.1 202.7 12.94 22.78
11⁄4 40 1.660 1.380 2.27 2.92 60 8.625 7.813 35.60 56.39
42.2 35.1 1.03 1.32 219.1 198.5 16.15 25.58
11⁄4" Framing

80 1.660 1.278 2.99 3.55 80 8.625 7.625 43.34 63.14


System

42.2 32.5 1.36 1.61 219.1 193.7 19.66 28.64


160 1.660 1.160 3.76 4.22 100 8.625 7.437 50.89 69.73
42.2 29.5 1.71 1.91 219.1 188.9 23.09 31.63
11⁄2 40 1.900 1.610 2.71 3.60 120 8.625 7.187 60.65 78.23
48.3 40.9 1.23 1.63 219.1 182.5 27.51 35.49
Framing

80 1.900 1.500 3.63 4.39 140 8.625 7.001 67.68 84.37


48.3 38.1 1.65 1.99 219.1 177.8 30.70 38.27
System

160 1.900 1.338 4.85 5.46 160 8.625 6.813 74.61 90.42
48.3 34.0 2.20 2.48 219.1 173.1 33.84 41.01
13⁄16"

2 40 2.375 2.067 3.65 5.10 10 20 10.750 10.250 28.01 63.78


60.3 52.5 1.66 2.32 273.1 260.4 12.70 28.93
80 2.375 1.939 5.02 6.30 30 10.750 10.136 34.20 69.19
Fiberglass

60.3 49.3 2.28 2.86 273.1 257.5 15.51 31.38


System

160 2.375 1.687 7.45 8.42 40 10.750 10.020 40.44 74.63


60.3 42.8 3.38 3.82 273.1 254.5 18.34 33.85
21⁄2 40 2.875 2.469 5.79 7.86 60 10.750 9.750 54.68 87.05
73.0 62.7 2.62 3.57 273.1 247.7 24.80 39.48
80 2.875 2.323 7.65 9.49 80 10.750 9.562 64.36 95.50
Special
Metals

73.0 59.0 3.47 4.30 273.1 242.9 29.19 43.32


160 2.875 2.125 10.00 11.54 100 10.750 9.312 76.95 106.47
73.0 54.0 4.54 5.23 273.1 236.5 34.90 48.30
3 40 3.500 3.068 7.57 10.77 120 10.750 9.062 89.20 117.16
PrimeAngle

88.9 77.9 3.43 4.89 273.1 230.2 40.46 53.14


System

80 3.500 2.900 10.24 13.11 140 10.750 8.750 104.02 130.09


88.9 73.7 4.65 5.94 273.1 222.3 47.18 59.01
160 3.500 2.624 14.31 16.65 160 10.750 8.500 115.52 140.13
88.9 66.6 6.49 7.55 273.1 215.9 52.40 63.56
31⁄2 40 4.000 3.548 9.10 13.39
Product

101.6 90.1 4.13 6.07


Index

80 4.000 3.364 12.49 16.35


101.6 85.4 5.67 7.41

170 Pipe/Conduit Supports


®
ELECTRICAL FITTINGS
Electrical Fittings ........................................ 173-175
Receptacles ........................................................ 176
Fixture Hangers ................................................. 177

Accessories and Connectors ..................... 178-181


Junction Boxes .................................................. 182
In-Channel Joiners ............................................. 183

Swivel Hangers ................................................. 184


Cable Entrance
Tubing and Accessories ............................. 185-188

Electrical Fittings Technical Data .............. 189-191

MATERIAL and is available in continuous lengths of up to 20 feet. Just as


important, it is part of an integrated system that can be used
Unistrut fittings, unless noted, are made from hot-rolled, for raceways, trapeze hangers, cable-tray supports, lighting
pickled and oiled steel plates, strip or coil, and conform to grids, fluorescent-fixture supports and countless other
ASTM specifications A575, A576, A635, or A36. The fitting electrical applications.
steel also meets the physical requirements of ASTM A1011
SS GR 33. The pickling of the steel produces a smooth
CHANNEL COMPATABILITY
surface free from scale.
All of the electrical components in this section are intended
Maple cable saddles, cable clamps and bus bar clamps are for use with any of the 15⁄8" wide channel. They are not
made from kiln-dry maple treated with paraffin to a depth of intended for use with 11⁄4" or 13⁄16" framing systems.
1
⁄16" (1.6mm). Special sizes of clamps can be fabricated upon
request. Porcelain cable clamps are made by the dry FINISHES
process and white glazed. Cable saddles are fiberglass-
reinforced polyester. Components listed in this section are available in: electro-
galvanized (EG), conforming to ASTM B633 Type III SC1;
Hot-dipped galvanized (HG), conforming to ASTM A123 or
CHANNEL RACEWAYS A153, Perma-Green II (GR), and plain (PL).
The Unistrut Metal Framing System includes an exclusive Note: Many Unistrut Metal Framing components, when used
combination of channel, fittings and hardware listed under with appropriate closures, are UL® listed, and CSA approved.
new UL classification 5B. This classification covers strut-type
channel raceways and fittings for use in accordance with DESIGN LOAD
Article 352 of the National Electrical Code, NFPA 70. Design load data, where shown, is based on the ultimate
Included are metal strut-type channel raceways at least .071 strength of the connection with a safety factor of 2.5, unless
inch (1.81mm) thick and metal or non-metal closure strips at otherwise noted.
least .040 inch (1.02mm) thick.
DIMENSIONS
The Unistrut system requires no welding, drilling or other Imperial dimensions are illustrated in inches. Metric
complex fabrication techniques. This means faster, easier dimensions are shown in parenthesis or as noted. Unless
solutions for virtually any electrical support problem. noted, all metric dimensions are in millimeters and rounded
Unistrut channel offers structural and spanning capabilities to one decimal place.
not available with conventional surface raceway products

171
® Electrical Fittings Pictorial Index

Electrical Fittings
Channel
15⁄8"
Telestrut
System

P1753-Pg 173 P2649 A-Pg 173 P2645 A-Pg 173 P2647 A-Pg 174 P1690-Pg 174 P1787-Pg 175
Hardware
Nuts &
General
Fittings

P2557-Pg 176 P2567-Pg 176 P2537-Pg 177 P2539-Pg 177 P2755-Pg 177 P2855-Pg 177
Pipe/Conduit
Supports

P3922-Pg 178 P2534-50-Pg 178 P2535-Pg 179 P2536-Pg 179 P2522-Pg 179 P3521-50-Pg 179
Electrical
Fittings

P2521-50-Pg 179 P5521-50-Pg 179 P5021-50-Pg 180 P2521-100-Pg 180 P5021-100-Pg 180 P5521-100-Pg 180
Concrete
Inserts
11⁄4" Framing

P1180 W-Pg 180 P2541-Pg 180 P2552-Pg 181 P2540-Pg 181 P2603-Pg 181 P3116-125-Pg 181
System
⁄16" Framing

P2602-Pg 182 P2801-Pg 182 P2802-Pg 182 P2803-Pg 182 P2900-Pg 183 P2901-Pg 183
System
13
Fiberglass
System

P2902-Pg 183 P2903-Pg 183 P2904-Pg 183 M2037-Pg 184 M2137-Pg 184 M2250-Pg 184
Special
Metals
PrimeAngle

M2350-Pg 184 P16F-Pg 185 P21H-Pg 185 P2820-Pg 187 P2822-Pg 187 P2823-Pg 187
System
Product
Index

P2821-Pg 187 P2920-Pg 188 P2928-Pg 188

172 Electrical Fittings


Electrical Fittings

P1753, P1754 Cable Saddles

Channel
15⁄8"
2" A

Telestrut
System
(50.8)

Maximum
Part “A” Cable Diameter Wt/100 pcs

Hardware
Number In (mm) In (mm) Lbs (kg)

Nuts &
P1753 FG 213⁄16 3 12
71.4 76.2 5.4
P1754 FG 33⁄4 41⁄2 17
95.3 114.3 7.7

General
Fittings
P1753 PO 3 3 75
76.2 76.2 34.0
P1754 PO 4 41⁄2 95
Material: FG - Fiberglass Reinforced Polyester, 101.6 114.3 43.1

Pipe/Conduit
PO - Dry Process White Glazed Porcelain

Supports
P2649A thru P2649H Maple Cable Saddles
Part Hole Size “A” “B” Wt/100 pcs
Number In (mm) In (mm) In (mm) Lbs (kg)
1 5⁄8"
P2649A 0-1 3 13⁄4 31

Electrical
(41.3) A

Fittings
0 - 25.4 76.2 44.5 14.1
Hole Size P2649B 1 - 11⁄2 31⁄2 2 38
25.4 x 38.1 88.9 50.8 17.2
B P2649C 11⁄2 - 2 4 21⁄4 47

Concrete
38.1 - 50.8 101.6 57.2 21.3

Inserts
P2649D 2 - 21⁄2 41⁄2 21⁄2 57
50.8 x 63.5 114.3 63.5 25.9
P2649E 21⁄2 - 3 5 23⁄4 68
63.5 - 76.2 127.0 69.9 30.8

11⁄4" Framing
P2649F 3 - 31⁄2 51⁄2 3 80

System
76.2 x 88.9 139.7 76.2 36.3
3
• ⁄8" Flat Head Machine Screw included. P2649G 31⁄2 - 4 6 31⁄4 94
• Specify hole size when ordering. 88.9 - 101.6 152.4 82.6 42.6
• Order channel nuts as required. P2649H over 4
Material: Maple hardwood paraffin impregnated. over 101.6

Framing
System
P2645A thru P2645H Maple Cable Clamps

13⁄16"
1 5 ⁄8 "
(41.3) A “A” & “B”
Part Hole Size Dimensions Wt/100 pcs

Fiberglass
Number In (mm) In (mm) Lbs (kg)

System
P2645A 0-1 31⁄2 84
0 - 25.4 88.9 38.1
Hole Size B P2645B 1 - 11⁄2 4 102
25.4 x 38.1 101.6 46.3
Special
Metals

P2645C 11⁄2 - 2 41⁄2 121


38.1 - 50.8 114.3 54.9
P2645D 2 - 21⁄2 51⁄2 165
50.8 x 63.5 139.7 74.8
PrimeAngle

P2645E 21⁄2 - 3 6 189


System

63.5 - 76.2 152.4 85.7


P2645F 3 - 31⁄2 61⁄2 215
76.2 x 88.9 165.1 97.5
P2645G 31⁄2 - 4 7 243
• 3⁄8" studs, square nuts and washers included.
88.9 - 101.6 177.8 110.2
• Specify hole size when ordering.
Product
Index

P2645H over 4
• Order channel nuts as required. over 101.6
Material: Maple hardwood paraffin impregnated.

Electrical Fittings 173


® Electrical Fittings

P2647A thru P2647F 4" (101.6) Bus Bar Maple Clamps


Channel
15⁄8"

1 5⁄8"
Telestrut

• 1⁄2" studs, square nuts and washers are included.


System

(41.3)
• Channel nuts must be ordered separately.
• Bus bar maple clamps also available in
1
A ⁄4" (6.4) x 2" (50.8) and 1⁄4" (6.4) x 6" (152.4).
B
Hardware
Nuts &

4"
(101.6)
General
Fittings

Part “A” “B” No. Bus No. Bars Wt/100 pcs


7 3⁄8" Number In (mm) In (mm) Separators Per Leg Lbs (kg)
(187.3)
P2647A 81⁄2 9
⁄32 0 1 421
Pipe/Conduit

215.9 7.1 191.0


Supports

1⁄4" (5.4) Maple P2647B 91⁄2 13


⁄16 2 2 465
Separator 241.3 20.6 210.9
P2647C 101⁄2 15⁄16 4 3 509
266.7 33.3 230.9
P2647D 111⁄2 113⁄16 6 4 553
292.1 46.0 250.8
Electrical
Fittings

P2647E 121⁄2 23⁄8 8 5 597


317.5 60.3 270.8
P2647F 131⁄2 27⁄8 10 6 631
342.9 73.0 286.2
Material: Paraffin impregnated maple hardwood.
Concrete
Inserts

P1690 thru P1697 Maple Cable Clamps


11⁄4" Framing
System

• Use with steel clamp and Everdur hardware.


Order clamp separately.
• Specify hole size when ordering.

Hole Size
⁄16" Framing
System
13

Order Steel
Part Clamp Hole Size “A” Wt/100 pcs
Number Number In (mm) In (mm) Lbs (kg)
Fiberglass
System

A P1690 P1113 E 0 -5⁄8 11⁄2 24


0 - 15.9 38.1 10.9
1
P1691 P1115 E ⁄2 - 1 21⁄8 42
12.7- 25.4 54.0 19.1
3
P1692 P1117 E ⁄4 - 11⁄2 25⁄8 54
Special
Metals

19.1 x 38.1 66.7 24.5


P1693 P1118 E 11⁄4 - 13⁄4 3 65
31.8 x 44.5 76.2 29.5
P1694 P1119 E 11⁄2 - 21⁄4 35⁄8 84
PrimeAngle

38.1 x 57.2 92.1 38.1


System

P1695 P1120 E 2 - 21⁄2 41⁄8 107


50.8 x 63.5 104.8 48.5
P1696 P1121 E 21⁄4 - 3 45⁄8 123
57.2 - 76.2 117.5 55.8
P1697 P1123 E 3-4 53⁄4 163
Product
Index

76.2 - 101.6 146.1 73.9


Material: Paraffin impregnated maple hardwood.

174 Electrical Fittings


Electrical Fittings

P1787 thru P1795 Porce-A-Clamp™

Channel
15⁄8"
Porce-A-Clamp™

Telestrut
System
• Non-Breakable TPE Material.
Hole Size • U.V. Resistant.
B • U.L. Listed.
• Optional Stainless Steel Clamps.

Hardware
• Tapered Flange to Protect Cable.

Nuts &
• Dielectric Strength 640 Volts Per Mil.
• One Piece Insulator.
• Replaces Porcelain & Maple Cable Clamp.
A • For use in accordance with National Electrical Code ANSI/NFPA 70.

General
Fittings
• Includes Pipe Strap.
Patents Pending
• Temperature Rating -50°F to +275°F (-45°C to +135°C)
Strap Material: Electro-galvanized Steel (EG) or Stainless Steel (SS)
Use With: All 15⁄8" channel

Pipe/Conduit
Supports
Hole Hole
Part Size “A” “B” Wt/100 pcs Part Size “A” “B” Wt/100 pcs

Electrical
Number In (mm) In (mm) In (mm) Lbs (kg) Number In (mm) In (mm) In (mm) Lbs (kg)

Fittings
3
P1787A ⁄8 1.36 1.82 25 P1791B 21⁄2
9.5 34.5 46.2 11.3 63.5
1
P1787B ⁄2 P1791C 25⁄8
12.7 66.7

Concrete
Inserts
5
P1787C ⁄8 P1792 23⁄4 3.86 4.75 109
15.9 69.9 98.0 120.7 49.4
3
P1788 ⁄4 1.86 2.34 37 P1792A 27⁄8
19.1 47.2 59.4 16.8 73.0
7

11⁄4" Framing
P1788A ⁄8 P1792B 3
22.2 76.2

System
P1788B 1 P1792C 31⁄8
25.4 79.4
P1788C 11⁄8 P1793 31⁄4 4.36 5.125 130
28.6 82.6 110.7 130.2 59.0
P1789 11⁄4 2.36 2.86 58 P1793A 33⁄8

Framing
31.8 59.9 72.6 16.8 85.7

System
P1789A 13⁄8 P1793B 31⁄2
34.9 88.9

13⁄16"
P1789B 11⁄2 P1793C 35⁄8
38.1 92.1
P1789C 15⁄8 P1794 33⁄4 4.86 5.54 160

Fiberglass
41.3 95.3 184.2 140.7 72.6

System
P1790 13⁄4 2.86 3.50 76 P1794A 37⁄8
44.5 72.6 88.9 34.5 98.4
P1790A 17⁄8 P1794B 4
47.6 101.6
Special

P1790B 2 P1794C 41⁄8


Metals

50.8 104.8
P1790C 21⁄8 P1795 41⁄4 5.24 5.92 160
54.0 108.0 133.1 150.4 72.6
P1791 21⁄4 3.36 4.05 90 P1795A 43⁄8
PrimeAngle
System

57.2 85.3 102.9 40.8 111.1


P1791A 23⁄8 P1795B 41⁄2
60.3 114.3
Product
Index

Electrical Fittings 175


® Receptacles

P2557 Duplex Grounded Receptacle


Channel
15⁄8"

Wt/100 pcs: 38 Lbs (17.2 kg)


Telestrut
System

P2553
Wire Connectors
• 125 V, 15 amp receptacle, NEMA configuration 5-15R, cover plate.
• #6 screws, nuts and wire connectors included.
• Leads are 14 gauge 105°C plastic covered.
Hardware

• Ground wire is green 16 gauge.


Nuts &
General
Fittings

6"
(152.4)
Oval Head
P3016-0632 #6-32 X 1"
Pipe/Conduit
Supports

19 Gauge
Electrical
Fittings
Concrete
Inserts

P3184 Closure
Finish: White powder coat.
11⁄4" Framing
System
⁄16" Framing
System

P2567 Outlet Box


Wt/100 pcs: 88 Lbs (47.8 kg)
13

17⁄8"
(47.6)
Fiberglass
System

4"
(101.6)

21⁄4"
Special
Metals

(57.2)
53⁄4"
(146.1)
PrimeAngle
System
Product
Index

Material: 14 Gauge (.075)


Assembly: 1 Box, 2 Screws, 2 Channel Nuts

176 Electrical Fittings


Fluorescent Fixture Hangers

P2537, P5537 P2539, P3539, P5539

Channel
15⁄8"
Fluorescent Fixture Hangers Fluorescent Fixture Hangers
1
⁄4" X 1" RHMS and
1
⁄4" X 1" RHMS and

Telestrut
Sq. Nut Included

System
Sq. Nut Included

Hardware
A

Nuts &
1 5⁄8" 1 5⁄8"
(41.3) (41.3)

General
Fittings
1
9
⁄32" (7.1) Dia. Hole ⁄4" X 3⁄4"
Carriage Bolt
and Sq. Nut Included
• Hanger provides more than • Hanger provides 1⁄8" (3.2)
1
⁄2" (12.7) space between space between channel

Pipe/Conduit
Supports
channel and fixtures. and fixtures.
Materials: 18 gauge (1.2). Use Materials: 18 gauge (1.2). Use
Part With “A” Wt/100 pcs Part With “A” Wt/100 pcs
Number Channel In (mm) Lbs (kg) Number Channel In (mm) Lbs (kg)
P1000 P1000
Design Load P2537 P1100 27⁄16 19 Design Load P2539 P1100 13⁄4 17

Electrical
Fittings
120 Lbs (54.4 kg) P3000 61.9 8.6 120 Lbs (54.4 kg) 44.5 7.7
P5537 P5500 31⁄4 22 P3539 P3000 11⁄2 15
82.6 10.0 38.1 6.8
P5539 P5500 29⁄16 18
65.1 8.2

Concrete
Inserts
P2755, P2756, P2757 Raceway Hangers P2855, P2856, P2857 Raceway Hangers

11⁄4" Framing
System
A A

4 1⁄4" 2 3⁄4"

Framing
(108.0) (69.9)

System
13⁄16"
9
⁄32" (7.1)
9 Sq. Hole
⁄32" (7.1)

Fiberglass
System
Sq. Hole

Use with Channels: Use with Channels:


P1001, P1101, P2001, P5000, & P5500. P1000, P1100, P3000, P3300
Special
Metals

Material: 14 gauge (1.9). Material: 14 gauge (1.9).


PrimeAngle

Part “A” Wt/100 pcs Part “A” Wt/100 pcs


System

Number In (mm) Lbs (kg) Number In (mm) Lbs (kg)


9 9
P2755 ⁄16 44 P2855 ⁄16 32
14.3 20.0 14.3 14.5
7 7
Design Load P2756 ⁄8 44 Design Load P2856 ⁄8 32
120 Lbs (54.4 kg) 22.2 20.0 120 Lbs (54.4 kg) 22.2 14.5
Product
Index

13 13
P2757 ⁄32 44 P2857 ⁄32 32
10.3 20.0 10.3 14.5

Electrical Fittings 177


® Electrical Accessories

P3922 thru P3926 Splice Fittings


Channel
15⁄8"

P2869 14 (1.9) Gage


Back Clevis
Telestrut
System

Threaded
Plate Nut
Hardware
Nuts &

6 3⁄4" 1
⁄4" X 5⁄8" Flat Head Machine Screws
(171.5) and 4 Hole Splice Plate Nut Included
General
Fittings

Use Back Plate


Assembly With “A” Clevis Clevis Nut Wt/100 pcs
Number Channel In (mm) Number Number Number Lbs (kg)
Pipe/Conduit
Supports

P3922 P1000 15⁄8 P2377 P2517 P2869 100


P1100 41.3 45.4
P3923 P3000 13⁄8 P3377 P2517 P2869 97
34.9 44.0
13
P3924 P4000 ⁄16 P5377 P2517 P2869 80
20.6 36.3
Electrical
Fittings

P3925 P5500 15⁄8 P2377 P5517 P2869 103


41.3 46.7
P3926 P5000 15⁄8 P2377 P5017 P2869 106
Material: 16 gauge (1.6). 41.3 48.1
Concrete
Inserts

P2534-50, P2534-75 Conduit Swing Fitting


Wt/100 pcs: 96 Lbs (43.5 kg)
11⁄4" Framing
System

2"
(50.8)
⁄16" Framing
System

Design Load
300 Lbs (136.1 kg)
13

P2534-50 For 1⁄2" Rigid Conduit


Fiberglass

P2534-75 For 3⁄4" Rigid Conduit


System

1
⁄4" X 3⁄4" Slotted Hex Head
Screws and Nuts Included
Special
Metals

4 13⁄16"
15° (122.2)
15° (.08π)
(.08π) 2" 2"
(50.8) (50.8)
PrimeAngle
System

2 Holes
9
⁄32" (7.1) 3⁄16"
(4.8)
Ground Wire
Bushing
Product

• Conduit hanger fittings allow a free swivel of 15° in one direction. Not Included
Index

• Fitting may be mounted to the slot side of the Unistrut channel or to the back.

178 Electrical Fittings


Electrical Accessories

P2535 Conduit Hanger Connection P2536 Conduit Hanger Connection

Channel
For 1⁄2"Conduit For 3⁄4"Conduit

15⁄8"
Wt/100 pcs: 28 Lbs (12.7 kg) Wt/100 pcs: 36 Lbs (16.3 kg)
1
⁄4" X 5⁄8" Flat Head
1
⁄4" X 5⁄8" Flat Head Machine Screws and

Telestrut
System
7
⁄8" (22.2) Dia. Machine Screws and P3016-1420 Nuts Included
1 3⁄32" (27.8) Dia.
P3006-1420 Nuts
Included

Hardware
Nuts &
1 5 ⁄8 "
4"

General
Fittings
(41.3) 5 1⁄8"
(101.6) (130.2)
Design Load Design Load
400 Lbs (181.4 kg) 200 Lbs (90.7 kg)
Material: 12 gauge (2.7). Material: 16 gauge (1.5)

Pipe/Conduit
Supports
P2522 Outlet Box Connection P3521-50 End Connectors
Wt/100 pcs: 35 Lbs (15.9 kg) For 1⁄2"Conduit
Wt/100 pcs: 27 Lbs (12.2 kg)
1
⁄4" X 5⁄8" Flat Head

Electrical
Fittings
Machine Screws and
1 15⁄16" P3016-1420 Nuts Included 7
1 3⁄16" (49.2) P3000 ⁄8" (22.2) Dia.
3
1 ⁄16" (30.2)
1 15⁄16" (30.2)

Concrete
Inserts
(49.2)

1 2 1⁄4"
⁄4" X 5⁄8" Flat Head Machine (57.2)
Screw and P3016-1420 Nut

11⁄4" Framing
Included

System
6 1⁄ 4"
(158.8) 3 Knockouts
7
⁄8" (22.2) Dia.
Material: 12 gauge (2.7).

Framing
System
P2521-50, P2521-75 End Connectors P5521-50, P5521-75 End Connectors
For 1⁄2" and 3⁄4" Conduit For 1⁄2" and 3⁄4" Conduit

13⁄16"
Fiberglass
A

System
A
P5500
1
⁄4" X 5⁄8" Flat Head
Machine Screw and 1
⁄4" X 5⁄8" Flat Head
P3016-1420 Nut Machine Screw and
Special

Included
Metals

P3016-1420 Nut
2 1⁄16" Included
(52.4)
1 3⁄8"
(34.9)
PrimeAngle
System

Conduit Conduit
Part Size A Wt/100 pcs Part Size A Wt/100 pcs
Number In Lbs (kg) Number In Lbs (kg)
1 1
P2521-50 ⁄2 27 P5521-50 ⁄2 27
Use with channels: 12.2 12.2
Product

3 3
P2521-75 ⁄4 26 P5521-75 ⁄4 26
Index

P1000 and P1100.


Material: 12 gauge (2.7) 11.8 Material: 12 gauge (2.7). 11.8

Electrical Fittings 179


® Electrical Accessories

P5021-50, P5021-75 End Connector P2521-100 End Connector


Channel

For 1⁄2" and 3⁄4" Conduit For 1" Conduit


15⁄8"

Wt/100 pcs: 24 Lbs (10.9 kg)

1
⁄4" X 5⁄8" Flat Head Tapped for 1"
Telestrut
System

Machine Screw and Conduit Thread


P3016-1420 Nut A
Included
P1000
Hardware

1
⁄4" X 5⁄8" Flat Head
Nuts &

Conduit Machine Screw and


P5000 P3016-1420 Nut
Part Size A Wt/100 pcs 2 1⁄16"
Number In Lbs (kg)
1 5⁄8" Included (52.4)
(41.3)
1
P5021-50 ⁄2 31
General
Fittings

14.1
3
P5021-75 ⁄4 30
13.6
Material: 12 gauge (2.7).
Pipe/Conduit

Material: 12 gauge (2.7).


Supports

P5021-100 End Connector P5521-100 End Connector


For 1" Conduit For 1" Conduit
Wt/100 pcs: 28 Lbs (12.7 kg) Wt/100 pcs: 24 Lbs (10.9 kg)
Electrical
Fittings

Tapped for 1"


Tapped for 1" Conduit Thread
Conduit Thread
Concrete
Inserts

1 P5500
P5000 ⁄4" X 5⁄8" Flat Head
1 5
⁄4" X ⁄8" Flat Head Machine Screw and
Machine Screw and P3016-1420 Nut
1 5⁄8"
Included
11⁄4" Framing

P3016-1420 Nut 1 5⁄8" (41.3)


Included
System

(41.3)

Material: 12 gauge (2.7). Material: 12 gauge (2.7).


⁄16" Framing
System

P1180W thru P5580 End Caps P2541 Spacer Clevis


Wt/100 pcs: 24 Lbs (10.9 kg)
13

7
⁄8" DIA.
(22.2)
Fiberglass
System

Part Use Wt/100 pcs


Number With Lbs (kg)
P1180W P1100 12 2"
5.4 2" (50.8)
P1280W P1000 11 (50.8)
Special
Metals

5.0 121⁄32" 4"


P2280W P2000 11 (42.1) (101.6)
5.0
UNISTRUT Channel
P3280W P3000 8 1
⁄8"
PrimeAngle

3.6 (3.2) P2541


System

P4280W P4000 5
2.3 P2540 Wiring
P5280W P5000 22 Stud Nut
10.0 Material: 12 gauge (2.7).
Flourescent Fixture
P5580W P5500 18
Product
Index

8.2
Material: 14 gauge (1.9)

180 Electrical Fittings


Electrical Accessories

P2552 Polypropylene Wire Retainer P2540, P2540A Wiring Stud Nut

Channel
15⁄8"
Wt/100 pcs: .30 Lbs (.1 kg)
1
⁄2" American Standard
Straight Pipe Thread

Telestrut
System
1 1⁄2" 1 1⁄2"
(38.1) (38.1)

Hardware
A

Nuts &
Stamped Ident. No.
Retainer may be easily pushed into P2540 – 121961
channel to support wires until P2540A – 121960
closure strip is installed.

General
Fittings
Design Load

Pipe/Conduit
320 Lbs (145.1 kg) Part “A” Wt/100 pcs

Supports
Number In (mm) Lbs (kg)
P2540 15⁄64 10.0
28.6 4.5
Material: Sintered metal. P2540A 5
⁄8 8
15.9 3.6

Electrical
Fittings
Concrete
Inserts
P2603 Fixture Wiring Nipple P3116-125 Fixture Stud Nut
Wt/100 pcs: 14 Lbs (6.4 kg) Wt/100 pcs: 11 Lbs (5.0 kg)

11⁄4" Framing
System
1.10"
(27.9)

Framing
1
⁄4" x 20 Thd.

System
2 1⁄8" 1 3⁄16"
(54.0) (30.2)

13⁄16"
Hole Dia.
.600" (15.2)

Fiberglass
.80"

System
(20.3)

Assembly: 1⁄2" x 2" rigid conduit nipple


Special
Metals

Bushing Locknut
PrimeAngle
System
Product
Index

Electrical Fittings 181


® Junction Boxes

P2602 Mecury Vapor Fixture Hanger


Channel
15⁄8"

Wt/100 pcs: 154 Lbs (69.9 kg)


Telestrut
System

6 3⁄4"
(171.5)
Hardware
Nuts &

Hole Size
1 1⁄16"
(27.0)
Requires P2603
General
Fittings

wiring nipple

Use with 15⁄8" Channel


Finish: Electro-galvanized
Stock Size: 1⁄4"
Pipe/Conduit
Supports

NOTE: Supports fixture in slot up or down system.

P2801 Junction Box P2802 Junction Box Cover


Wt/100 pcs: 113 Lbs (51.4 kg) Wt/100 pcs: 30 Lbs (13.6kg)
Electrical
Fittings

2 1⁄4"
(57.2) 4"
(101.6)

4 3⁄16"
Concrete

4 3⁄16"
Inserts

(106.4)
(106.4)
4"
(101.6)
11⁄4" Framing
System
⁄16" Framing
System

P2803 Hub Assembly


3" 1 11
⁄16" Wt/100 pcs: 32 Lbs (14.5 kg)
13

(76.2) (42.9)
Fiberglass
System

2" P2803 Hub


(50.8)
Special
Metals

Stamp ID No. 122022 P1000


Channel
P2801
PrimeAngle

Junction Box
System
Product

Note: Combine junction box (P2801) and


Index

hub assemblies (P2803) to make


P2801 1, 2, 3, or 4 way junction box.

182 Electrical Fittings


In-Channel Joiners

P2900 Wt/100 pcs: 20 Lbs (9.1 kg) P2901 Wt/100 pcs: 35 Lbs (15.9 kg)

Channel
15⁄8"
3
/8"-16 x 1/4"
Socket Cup Point

Telestrut
System
P1000 Set Screws Included

Hardware
Nuts &
3
/8"-16 x 1/4"
Socket Cup Point
Set Screws Included P1000

General
Fittings
Pipe/Conduit
Supports
Material: Cast aluminum. Material: Cast aluminum.

P2902 Wt/100 pcs: 27 Lbs (12.2 kg) P2903 Wt/100 pcs: 45 Lbs (20.4 kg)

Electrical
Fittings
P1000

P1000

Concrete
3
/8"-16 x 1/4"

Inserts
Socket Cup Point
Set Screws Included

11⁄4" Framing
System
3
/8"-16 x 1/4"
Socket Cup Point
Set Screws Included

Material: Cast aluminum. Material: Cast aluminum.

Framing
System
Wt/100 pcs: 12 Lbs (5.4kg)
P2904

13⁄16"
P3300, P4000,
P4100

Fiberglass
System
Special
Metals

3
/8"-16 x 1/4"
Socket Cup Point
Set Screws Included
PrimeAngle

Extruded Aluminum
System
Product
Index

Electrical Fittings 183


® Swivel Hangers

M2037, M2050 Swivel Hangers M2137, M2150 Swivel Hangers


Channel
15⁄8"

A
A
Telestrut
System

3
⁄8" (9.5) DIA.
B
3
⁄8" (9.5) DIA.
Hardware
Nuts &

1"
General

(24.5)
Fittings

A
A
Pipe/Conduit
Supports

Design Load Design Load


600 Lbs (271.8 kg) 600 Lbs (271.8 kg)

Part “A” “B” Wt/100 pcs Part “A” “B” Wt/100 pcs
Number In In (mm) Lbs (kg) Number In In (mm) Lbs (kg)
Electrical
Fittings

3
M2037 ⁄8" - 16 231⁄32 23 M2137 3
⁄8" - 16 229⁄32 27
75.4 10.4 73.8 12.2
1
M2050 ⁄2" - 13 23⁄4 32 M2150 1
⁄2" - 13 23⁄4 45
69.9 14.5 69.9 20.4
Concrete
Inserts

M2250 Swivel Hanger M2350 Swivel Hanger


Wt/100 pcs: 18 Lbs (8.2 kg) Wt/100 pcs: 20 Lbs (9.1 kg)
11⁄4" Framing
System

1 3⁄4" 3
⁄8" (9.5) DIA.
3
⁄8" (9.5) DIA. (44.5)
⁄16" Framing

1 3⁄4"
System

(44.5)
1"
1
⁄2" - 13 THD. (24.5)
13
Fiberglass
System

1
⁄2" - 13 THD.
Special
Metals

Design Load Design Load


600 Lbs (271.8 kg) 600 Lbs (271.8 kg)
PrimeAngle
System
Product
Index

184 Electrical Fittings


Cable Entrance Tubing

P16F Wt/100 Ft: 178 Lbs (260 kg/100 m) P21H Wt/100 Ft: 297 Lbs (440 kg/100 m)

Channel
Allowable Moment 4,800 In-Lbs (540 N•m) Allowable Moment 11,370 In-Lbs (540 N•m)

15⁄8"
12 Gauge Nominal Thickness .105" (2.7mm) 12 Gauge Nominal Thickness .105" (2.7mm)

Slot spacing

Telestrut
System
Slot spacing Slot Size 11⁄4" (31.8)
Slot Size 11⁄4" (31.8) 3
⁄4" (19.1) X on center.
3 on center. 7
⁄4" (19.1) X ⁄8" (22.2)
7
⁄8" (22.2)

Hardware
Nuts &
2 3⁄16"
(55.6) 7
⁄32" (5.6)
1 3⁄4"
(44.5) 7
⁄32" (5.6) 2
Slot Size Slot Size
2 17⁄32" (13.5) X 17⁄32" (13.5) X

General
Fittings
7
⁄8" (22.2) 2 5⁄32" 7
⁄8" (22.2)
1 23⁄32" 1 1 (54.8)
1 1 (43.7)

Pipe/Conduit
2 2

Supports
7
7 ⁄32" (5.6)
⁄32" (5.6)

Tubing Finishes: PL, GR, HG, PG; Standard Lengths: 10' & 20' Tubing Finishes: PL, GR, HG, PG; Standard Lengths: 10' & 20'

COLUMN LOADING – P16F COLUMN LOADING –P21F

Electrical
Fittings
Max. Allowable Load Max. Allowable Load Max. Allowable Load Max. Allowable Load
Unbraced Column Loaded Column Loaded Unbraced Column Loaded Column Loaded
Height at C.G. at Slot Face Height at C.G. at Slot Face
In Lbs Lbs In Lbs Lbs

Concrete
Inserts
24 9,600 3,300 24 17,700 6,200
36 9,000 3,100 36 16,900 6,000
48 8,300 2,900 48 16,000 5,700
60 7,500 2,700 60 15,000 5,400

11⁄4" Framing
System
72 6,600 2,400 72 13,900 5,100
84 5,600 2,200 84 12,600 4,700
96 4,500 1,900 96 11,300 4,300
108 3,600 1,600 108 9,900 3,900
120 2,900 1,400 120 8,300 3,500

Framing
System
144 2,000 1,100 144 5,800 2,800
168 4,230 2,300

13⁄16"
COLUMN LOADING – P16F (METRIC) COLUMN LOADING –P21F (METRIC)
Max. Allowable Load Max. Allowable Load Max. Allowable Load Max. Allowable Load

Fiberglass
System
Unbraced Column Loaded Column Loaded Unbraced Column Loaded Column Loaded
Height at C.G. at Slot Face Height at C.G. at Slot Face
mm kg kg mm kg kg
610 4,354 1,497 610 8,029 2,812
Special
Metals

914 4,082 1,406 914 7,666 2,722


1,219 3,765 1,315 1,219 7,257 2,585
1,524 3,402 1,225 1,524 6,804 2,449
PrimeAngle

1,829 2,994 1,089 1,829 6,305 2,313


System

2,134 2,540 998 2,134 5,715 2,132


2,438 2,041 862 2,438 5,126 1,950
2,743 1,633 726 2,743 4,491 1,769
3,048 1,315 635 3,048 3,765 1,588
Product
Index

3,658 907 499 3,658 2,631 1,270


4,267 1,919 1,043

Electrical Fittings 185


® Cable Entrance Tubing

BEAM LOADING – P16F BEAM LOADING – P21F


Channel
15⁄8"

Max Defl. at Max Defl. at


Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360
Telestrut
System

In Lbs In Lbs Lbs Lbs In Lbs In Lbs Lbs Lbs


24 1,600 0.06 1,600 1,600 1,600 24 3,790 0.05 3,790 3,790 3,790
36 1,070 0.13 1,070 1,070 820 36 2,530 0.11 2,530 2,530 2,380
48 800 0.23 800 690 460 48 1,900 0.19 1,900 1,900 1,340
Hardware
Nuts &

60 640 0.36 590 440 290 60 1,520 0.29 1,520 1,280 860
72 530 0.52 410 310 200 72 1,260 0.42 1,190 890 590
84 460 0.71 300 220 150 84 1,080 0.58 870 660 440
96 400 0.93 230 170 110
General

96 950 0.76 670 500 330


Fittings

108 360 1.18 180 140 90 108 840 0.96 530 400 260
120 320 1.45 150 110 70 120 760 1.18 430 320 210
144 270 2.09 100 80 50 144 630 1.70 300 220 150
Pipe/Conduit

168 230 2.85 70 60 40 168 540 2.31 220 160 110


Supports

BEAM LOADING – P16F (METRIC) BEAM LOADING – P21F (METRIC)


Max Defl. at Max Defl. at
Electrical
Fittings

Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360
mm kg mm kg kg kg mm kg mm kg kg kg
600 737 1 737 737 737 600 1747 1 1747 1747 1747
Concrete
Inserts

750 590 2 590 590 550 750 1397 2 1397 1397 1397
1,000 442 4 442 442 309 1,000 1048 3 1048 1048 902
1,250 354 6 354 297 198 1,250 838 5 838 838 578
1,500 295 9 275 206 138 1,500 699 7 699 602 401
11⁄4" Framing
System

1,750 253 12 202 152 101 1,750 599 10 589 442 295
2,000 221 16 155 116 77 2,000 524 13 451 338 226
2,500 177 25 99 74 50 2,500 419 20 289 217 144
3,000 148 36 69 52 34 3,000 349 29 201 150 100
3,500 126 49 51 38 25 3,500 299 40 147 111 74
⁄16" Framing

4,000 111 64 39 29 19 4,000 262 52 113 85 56


System

Notes:
1. Above loads include the weight of the member. This weight must be deducted to arrive at the net allowable load the beam will support.
13

2. Long span beams should be supported in such a manner as to prevent rotation and twist.
3. Allowable uniformly distributed loads are listed for various simple spans, that is, a beam on two supports. If load is concentrated at the center
Fiberglass
System

of the span, multiply load from the table by 0.5 and corresponding deflection by 0.8.

ELEMENTS OF SECTION – P16F ELEMENTS OF SECTION – P21H


Special
Metals

Parameter P16F P16F (metric) Parameter P21H P21H (metric)


Area of Section 0.416 In2 2.68 cm2 Area of Section 0.749 In2 4.83 cm2
Axis 1-1 Axis 1-1
PrimeAngle

Moment of Inertia (I) 0.168 In4 7.0 cm4 Moment of Inertia (I) 0.490 In4 20.4 cm4
System

Section Modulus (S) 0.192 In3 3.1 cm3 Section Modulus (S) 0.455 In3 7.5 cm3
Radius of Gyration (r) 0.650 In 1.7 cm Radius of Gyration (r) 0.820 In 2.1 cm
Axis 2-2 Axis 2-2
Moment of Inertia (I) 0.210 In4 8.7 cm4 Moment of Inertia (I) 0.590 In4 24.6 cm4
Product

Section Modulus (S) 0.240 In3 3.9 cm3 Section Modulus (S) 0.540 In3 8.8 cm3
Index

Radius of Gyration (r) 0.725 In 1.8 cm Radius of Gyration (r) 0.900 In 2.3 cm

186 Electrical Fittings


Cable Entrance Fittings

P2820, P2940 Channel/Tube Connectors P2822, P2932 Splice Fittings

Channel
15⁄8"
Telestrut
System
5 3⁄8"
(136.5)
3 3⁄4" Splice Fitting Assembly

Hardware
(95.3)

Nuts &
Secured to Flat Side with
1 5⁄8" Hardware Provided
(41.3)
Use Either Threaded Hole

General
Fittings
9
⁄16" (14.3) Dia. Holes

3" 7
⁄16" (11.1) Dia. Holes
(76.2) Splicing should occur

Pipe/Conduit
within the top one quarter

Supports
of column height.

Electrical
Fittings
Part Use Wt/100 pcs Part Use Wt/100 pcs
Number With Lbs (kg) Number With Lbs (kg)
P2820 P16F 116 P2822 P16F 97

Concrete
Inserts
2.6 44.0
P2940 P21H 148 P2932 P21H 122
67.1 55.3

11⁄4" Framing
P2823 90° Rack Fitting P2821 Locking Clip

System
Wt/100 pcs: 66 Lbs (29.9 kg) Wt/100 pcs: 3 Lbs (1.4 kg)

Framing
System
P4000

13⁄16"
P2821
Locking Clip

Fiberglass
5" Cable Hook System
(127.0) supplied by others.
Special
Metals
PrimeAngle
System

Exclusive Cable Hook


Locking Clip prevents
Cable Hook removal.
Product
Index

Electrical Fittings 187


® Cable Entrance Fittings

P2920 thru P2924 Cable Brackets


Channel
15⁄8"

1 5⁄8"
3 3
⁄16" (4.8) x ⁄4" (19.1) Slots (41.3)
Telestrut

2 3⁄4" (69.9) on Center


System

B
Hardware
Nuts &

L Use with P16F or P21H.


General
Fittings

Material: 12 gauge steel.


Uniform
Pipe/Conduit
Supports

Part Wt/100 pcs Design Load


Number “L” “A” “B” Lbs (kg) Lbs (kg)
P2920 51⁄2 31⁄2 7
⁄8 90 500
139.7 88.9 22.2 40.8 2.2
P2921 81⁄4 31⁄2 7
⁄8 120 325
209.6 88.9 22.2 54.4 1.4
Electrical
Fittings

P2922 11 31⁄2 15⁄8 300 275


279.4 88.9 41.3 136.1 1.2
P2923 133⁄4 31⁄2 15⁄8 340 220
349.3 88.9 41.3 154.2 1.0
191⁄4 31⁄2 15⁄8
Concrete

P2924 430 160


Inserts

489.0 88.9 41.3 195.0 0.7

Safety factor of 3.
11⁄4" Framing

P2928, P2929 and P2930 Cable Brackets


System

1 5⁄8"
(41.3)
⁄16" Framing
System

B
13

A
Fiberglass
System

Use with P16F or P21H.


Special
Metals

Material: 12 gauge steel.


Uniform
Part Wt/100 pcs Design Load
PrimeAngle

Number “L” “A” “B” Lbs (kg) Lbs (kg)


System

P2928 6 31⁄2 7
⁄8 92 500
152.4 88.9 22.2 41.7 2.2
P2929 12 31⁄2 15⁄8 320 250
304.8 88.9 41.3 145.1 1.1
P2930 18 31⁄2 15⁄8 420 170
Product
Index

457.2 88.9 41.3 190.5 0.8


Safety factor of 3.

188 Electrical Fittings


Electrical Technical Data

U.L. Listed

Channel
15⁄8"
Unistrut channel is listed by Underwriters' Laboratories as a P3000, & -KO
surface metal raceway. Snap-in closure strip is used to
Number and Conductor Size (AWG)
complete the raceway. Accessory parts listed by Underwriters Gauge 14 12 10 8 6
are noted on drawings.

Telestrut
System
THWN, THHN 72 54 34 17 12
The following tables represent maximum number of conduc- XHHW 48 37 29 13 10
tors when raceway is not employed with fixtures or where the T, TW 46 36 28 13 7
clearance between fixtures and raceway is greater than 1⁄2" THW 30 25 20 10 7
(12.7). In all cases the snap-in cover is required to complete RH 27 22 13 7 5

Hardware
Nuts &
RHH, RHW 19 16 13 7 5
raceway enclosure.
P3300 P5500, & -KO
Number and Conductor Size (AWG) Number and Conductor Size (AWG)
Gauge 14 12 10 8 6 Gauge 14 12 10 8 6

General
Fittings
THWN, THHN 40 30 19 9 6 THWN, THHN 141 105 66 33 23
XHHW 26 21 16 7 5 XHHW 93 73 57 27 19
T, TW 26 20 15 7 4 T, TW 91 58 55 26 15
THW 17 14 11 6 4 THW 59 49 39 20 15

Pipe/Conduit
RH 15 12 7 4 3 RH 53 44 26 14 10

Supports
RHH, RHW 10 9 7 4 2 RHH, RHW 37 32 26 14 10

P1000, & -KO, P1100 & -KO P5000, & -KO


Number and Conductor Size (AWG) Number and Conductor Size (AWG)
Gauge 14 12 10 8 6 Gauge 14 12 10 8 6

Electrical
Fittings
THWN, THHN 88 66 42 20 14 THWN, THHN 193 105 91 45 32
XHHW 58 46 35 16 12 XHHW 128 101 78 37 27
T, TW 57 44 34 16 9 T, TW 125 98 75 35 20
THW 37 30 24 12 9 THW 81 67 54 28 20
RH 33 27 16 9 6 RH 73 60 36 19 13

Concrete
RHH, RHW 23 20 16 9 6 RHH, RHW 51 44 36 19 13

Inserts
Channel Size and Inside Area Note: Raceways with external joiners shall use a 40% wire fill
Channel Part Number Size Area 40% Area 25% Area calculation to determine the number of conductors

11⁄4" Framing
P3300 & KO 15⁄8" x 7⁄8" 0.975 0.390 0.244 permitted.

System
629 252 157
P3000 & KO 15⁄8" x 13⁄8" 1.677 0.671 0.419 Raceways with internal joiners shall use a 25% wire fill
1,082 433 270 calculation to determine the number of conductors
P1000 & KO, P1100 & KO 15⁄8" x 15⁄8" 2.028 0.811 0.507
permitted
1,308 523 327
P5500 & KO 15⁄8" x 27⁄16" 3.169 1.268 0.792

Framing
2,045 818 511
P5000 & KO 15⁄8" x 31⁄4" 4.308 1.723 1.077

System
13⁄16"
C.S.A. APPROVED
Suitable for number of wires in Column A when installed to discharge type lighting fixtures when raceway wiring is suitable

Fiberglass
System
support and supply electric discharge type lighting fixtures for at least 75° C and clearance between fixtures and raceway
when raceway wiring is suitable for at least 75° C except wire is at least 1⁄8" (3.2).
suitable for 60° C may be used when clearance between
Maximum number of wires for types T, THHN,
fixtures and raceways is at least 1⁄2" (12.7). Also suitable for
THW, THWN, TW, R, RH, RHH, RHW or XHHW
number of wires in column B when installed to support electric
Special
Metals

Raceway Wire P1000, &-KO


PrimeAngle

Size P1100, &-KO P3000, &-KO P3300 P5000 &-KO P5500, &-KO
System

AWG A B A B A B A B A B
14 6 10 5 10 4 6 10 10 10 10
12 6 10 4 10 3 6 10 10 10 10
10 5 8 4 6 - - 8 10 8 10
8 4 6 3 4 - - 6 9 6 8
Product

6 2 3 2 2 - - 4 6 4 6
Index

Unistrut channels are also certified by Canadian Standards Association.

Electrical Fittings 189


® Electrical Technical Data

Fluorescent Fixtures - Support Applications


Channel
15⁄8"

Slotted channel attachment system


Spring-Nut attachment system
Telestrut
System
Hardware
Nuts &
General
Fittings
Pipe/Conduit
Supports

Conduit connects through knockout in fixture. Fixture Conduit connects through knockout in fixture. Fixture is
is supported by P1006-1420 spring nut and 1/4" round supported by HCSS series hex bolt and hex nut. Raceway
head machine screw. Assembly is supported by is supported by P2855 hanger. To splice a continuous run,
P2855 hinged hanger. use P3922.
Electrical
Fittings
Concrete
Inserts

Recommended Support Spacing for Fixtures


Deflections are based on continuity of span and use of 4 ft.
11⁄4" Framing

fixtures weighing approximately 30 lbs. each. Do not use joiner


System

fittings between supporting hangers. When using knock-out or


slotted channels deflections will be increased approximately
5%. With fixtures spaced 2' - 0" apart, deflection is 60-70% of
table. When spaced 4' - 0" apart, deflection is 50-60% of table.
⁄16" Framing
System

Deflection Table
Distance Between Supports
13

8' (2.4m) 10' (3m) 12' (3.7m) 14' (4.3m) 16' (4.9m) 18' (5.5m) 20' (6.1m) 22' (6.7m) 24' (7.3m)
Channel In (mm) In (mm) In (mm) In (mm) In (mm) In (mm) In (mm) In (mm) In (mm)
Fiberglass

P3300 0.187
System

4.7
P3000 0.100 0.250 0.500
2.5 6.4 12.7
P1100 0.088 0.250 0.437 0.875
2.2 6.4 11.1 22.2
Special
Metals

P1000 0.180 0.312 0.625 1.000 1.625


4.6 7.9 15.9 25.4 41.3
P5500 0.250 0.500 0.812 1.620
6.4 12.7 20.6 41.1
PrimeAngle

P5000 0.310 0.625 1.000 1.800 2.500


System

7.9 15.9 25.4 45.7 63.5


P1001 0.310 0.625 1.000 1.800 2.500
7.9 15.9 25.4 45.7 63.5
P5001 0.200 0.250 0.400 0.500
5.1 6.4 10.2 12.7
Product
Index

190 Electrical Fittings


Electrical Technical Data

High-Bay Fixture Raceway Applications

Channel
15⁄8"
High-Bay dual

Telestrut
H.I.D. Knockout

System
mounted system
mounted system

Hardware
Nuts &
General
Fittings
Fixture attached to and wired from raceway by 1⁄2" nipple assembly of
desired length at channel knockout. P1280W end cap, P3184 closure
strip, P2535 conduit connector, and P2855 channel hanger complete
assembly. For splicing channels into continuous raceway runs, use
joiner fitting P3922. Fixtures are connected to and wired form raceway by conduit

Pipe/Conduit
connector fitting P2536. Raceway is supported by P2855 hanger.

Supports
P1280W endcaps and P3184 closure strip complete the assembly.
Conduit connected to raceway through channel knockout.

Electrical
Fittings
H.I.D. Plug-in system
(with swivel)

Concrete
H.I.D. Plug-in system

Inserts
(rigid mount)

11⁄4" Framing
System
Fixtures, supported by P2855 hangers and M2250 eyelets, plug
into receptacle mounted in P2763 outlet box. P2855 hangers
also support raceway. P2521-75 end connector joins conduit to
raceway. P1280W end caps (not shown) and P3184 closure strip
complete assembly.

Framing
System
13⁄16"
Fixtures are supported by P2602 clevis hangers. Cover plate on
P2761 outlet box provides access to receptacle box. Raceway is
supported and wired by top mounted P2535 conduit connectors.
P1280W end caps and P3184 closure strip complete assembly.

Fiberglass
System
Uplighting with underhung
Special
Metals

or remote ballast
PrimeAngle

Fixtures attached to and wired from P2535 conduit fittings mounted to


System

slot side of channel. Raceway can be wired by P2521 as shown or,


conduit can enter through available knockout. Ballasts in P2521 are
connected at the knockout by fixture adapter. In remote ballast
installations, follow manufacturers instructions. P2855 hinged hangers
support both types of installations. P3184 closure strip and P1280W
end caps complete assembly. For continuous raceways, use joiner
Product
Index

fitting P3922. P2521-75 end connector joins conduit to raceway.

Electrical Fittings 191


Product PrimeAngle Special Fiberglass 13 Concrete Electrical Pipe/Conduit General Nuts & Telestrut
⁄16" Framing 11⁄4" Framing 15⁄8"
Index System Metals System System System Inserts Fittings Supports Fittings Hardware System Channel

192
®
Electrical Technical Data

Electrical Fittings
®
CONCRETE INSERTS
Heavy-Duty Inserts .......................................... 195
Standard-Duty Inserts ............................. 196-197

Light-Duty Inserts ............................................ 198


Spot Inserts ....................................................... 199
Deck Inserts ...................................................... 200

Components ..................................................... 201


Technical Data .................................................. 202

MATERIAL DESIGN LOAD


Cold-formed inserts are manufactured from standard 12 Design loads, where shown, are based on 3,000 PSI
gauge (2.7 mm) Unistrut channel sections conforming to concrete, unless noted.
ASTM A1011 SS GR 33 or ASTM A653 GR 33, unless other-
wise noted.
STANDARD LENGTHS
Hot-rolled inserts, as noted, are manufactured from carbon
steel meeting physical requirements of ASTM A283 GR D. Insert lengths range from 3 inches (76 mm) to 20 feet
(6.10m) with a tolerance of ± 1⁄4-inch (6.4mm).
To inhibit concrete seepage, all inserts (except spot inserts)
are provided with closure strips and end caps or foam filler,
unless otherwise requested. DIMENSIONS
Most concrete inserts are available in stainless steel on Imperial dimensions are illustrated in inches. Metric
special order. Consult factory for ordering information. dimensions are shown in parentheses or as noted. Unless
noted, all metric dimensions are in millimeters and rounded
to one decimal place.
APPLICATION
Custom-designed inserts are available on special order.
A wide range of heavy-duty to light-duty “continuous” and Consult factory for ordering information.
“spot” concrete inserts are available for use in pre-cast, pre-
stressed or poured-in-place concrete floors, walls or ceilings.

FINISHES
Cold-formed, standard-duty, light-duty and spot concrete
inserts are available in Perma-Green II (GR), hot dipped
galvanized (HG), conforming to ASTM A123 or A153;
pre-galvanized (PG), conforming to ASTM A653 GR 33
and plain (PL).

193
® Concrete Inserts Pictorial Index

Heavy Duty Light Duty


Channel
15⁄8"
Telestrut
System

P3349-Pg 198 P3352-Pg 198 9P3354-Pg 198


P3754-Pg 195
Hardware
Nuts &

Standard Duty
General
Fittings
Pipe/Conduit

P3249-Pg 196 P3253-Pg 196 P3253-Pg 196 P3165-Pg 197 P2865-Pg 197
Supports

Spot Inserts and Components


Electrical
Fittings

P3245-Pg 199 P3245N4-Pg 199 M24-Pg 199 M2506-Pg 199 P3700-Pg 200
Concrete
Inserts
11⁄4" Framing
System

P1703-Pg 201 P2407-Pg 201 P3663-Pg 201

Fiberglass Concrete Inserts Closure Strips


⁄16" Framing
System
13
Fiberglass

Heavy Duty-Pg 250 Standard Duty-Pg 254 Light Duty-Pg 252 P3712-Pg 59 P1184-Pg 59 P1184 PVC-Pg 59
System
Special
Metals

P3184-Pg 59 P3184P-Pg 59

Channel Nuts
PrimeAngle
System
Product
Index

Heavy Duty-Pg 78 Heavy Duty-Pg 78 Standard Duty-Pg 78 Standard Duty-Pg 78 Light Duty-Pg 78 Light Duty-Pg 78

194 Concrete Inserts


Installation and Heavy Duty Inserts

Channel
Installing Concrete Inserts Using Installed Concrete Insert

15⁄8"
1. Nail insert to 2. Attach rebars
concrete form using to flanges on

Telestrut
System
prepunched nail insert
holes

Hardware
Nuts &
Concrete
Form

General
Fittings
Pipe/Conduit
Supports
The Unistrut concrete insert is firmly fixed to the concrete side of the form 1. Scrape out filler 2. Insert channel nut. 3. Attach fitting
before pouring. When the forms are removed, the insert is ready for use.
Brackets and other components can be attached at any point of the
continuous entry channel.

Electrical
Fittings
P3754 Series 15⁄8" x 15⁄8" Channel

• Closure strip P3712 P and a styrene bead end cap that fits inside the channel
to inhibit concrete seepage are included.

Concrete
Inserts
• The recommended design load when used for curtain wall anchorage is
5,000 pounds and is based on use in average, good concrete. The design
load includes 1⁄3 increase in load as permitted by AISI Specifications and
Uniform Building Code when stresses are produced by wind or earthquake

11⁄4" Framing
and other loads.

System
• The recommended design load is based on using two P1010 nuts at no less
than 3" O.C. and no closer than 2" to either end of the insert. The distance
between the insert centerline and the concrete edge must be a minimum of 3".
• All nuts and fittings for P3200 series concrete inserts will fit.
• Material: Cold formed from 12 Ga. (2.7mm) steel conforming to ASTM
A1011 SS GR 33 or ASTM A653 GR 33 A. Stainless steel available on special

Framing
order.

System
• Finish: Choice of Perma-Green II (GR), hot-dipped galvanized (HG)
conforming to ASTM A123 or A153, pre-galvanized (PG) conforming to

13⁄16"
ASTM A653-G90, or plain (PL).

Fiberglass
8" 5 3⁄4"

System
(203.2) (146.1)

1 5⁄8"
(41.3)
Special
Metals

1'-0" 1 5⁄8" P3712P


(304.8) (41.3)
PrimeAngle
System

Insert Max. Max. Spacing Max.


3" Part Length Wt/100 Anchor Allowable of Point Allowable
(76.2) Number ±1⁄4" (6.4mm) pcs Spacing Point Load Loads Uniform Load
Load In (mm) Lbs (kg) In (mm) Lbs (kg) In (mm) Lbs (kg)
3" P3754 12 210 8 2,500 3 5,000
(76.2)
Product

304.8 95.3 203.2 1,134.0 76.2 2,268.0


Index

Safety factor 3

Concrete Inserts 195


® Standard Duty

P3200 Series 15⁄8" x 13⁄8" Channel


Channel
15⁄8"

FM
• when used for sprinkler systems.
P3249 thru P3252 • Includes closure and end caps unless otherwise requested.
• P3280 end cap used when distance to first anchor is up to 2" (50.8 mm).
Telestrut
System

• P3704 end cap is used when end distance to first anchor is over 2" (50.8 mm).
• Nail or anchor inserts to forms every 16" (406 mm) to 24" (610 mm).
• Anchors are 8" (203.2 mm) on center.
• Material: Cold formed from 12 Ga. (2.7 mm) steel conforming to
ASTM A1011 SS GR 33 or ASTM A653 GR 33. A. Stainless steel
Hardware
Nuts &

available on special order.


• Finish: Choice of Perma-Green II (GR), hot-dipped galvanized (HG)
"NC" Suffix – No Closure Strip, With End Caps conforming to ASTM A123 or A153, pre-galvanized (PG) conforming to
"WC" Suffix – With Closure Strip & End Caps ASTM A653-G90, or plain (PL).
General
Fittings

Max. Min. Max.


Insert Wt/100 Allowable Spacing Allowable
P3253 Part Length pcs Point Load of Pt. Loads Uniform Load
Number In/Ft (mm) Lbs (kg) Lbs (kg) In (mm) Lbs (kg)
P3249 3" 85 500 — 500
Pipe/Conduit

76.2 38.6 226.8 226.8


Supports

P3250 4" 100 800 — 800


101.6 45.4 362.9 362.9
P3251 6" 130 1,000 — 1,000
152.4 59.0 453.6 453.6
P3252 8" 159 1,200 — 1,200
Electrical

"NC" Suffix – No Closure Strip, With End Caps & Back Plates
Fittings

203.2 72.1 544.3 544.3


"WC" Suffix – With Closure Strip, End Caps & Back Plates P3253 12" 227 2,000 — 2,000
304.8 103.0 907.2 907.2
P3254 16" 270 2,000 12 4,000
406.4 122.5 907.2 304.8 1,814.4
Concrete
Inserts

P3255 20" 357 2,000 12 4,000


P3254 thru P3270 508.0 161.9 907.2 304.8 1,814.4
P3256 24" 399 2,000 12 4,000
8" 609.6 181.0 907.2 304.8 1,814.4
11⁄4" Framing

(203.2) P3257 32" 527 2,000 12 2,000 Lbs./Ft.


System

812.8 239.0 907.2 304.8 2,976.3 (kg/m)


P3257A 36" 616 2,000 12 2,000 Lbs./Ft.
914.4 279.4 907.2 304.8 2,976.3 (kg/m)
P3258 40" 661 2,000 12 2,000 Lbs./Ft.
1,016.0 299.8 907.2 304.8 2,976.3 (kg/m)
P3259 4' 786 2,000 12 2,000 Lbs./Ft.
⁄16" Framing

1,219.2 356.5 907.2 304.8 2,976.3 (kg/m)


System

"NC" Suffix – No Closure Strip, W/End Caps & Back Plates P3260 5' 1,003 2,000 12 2,000 Lbs./Ft.
"WC" Suffix – W/Closure Strip, End Caps & Back Plates
1,524.0 455.0 907.2 304.8 2,976.3 (kg/m)
P3261 6' 1,173 2,000 12 2,000 Lbs./Ft.
13

"X" – No Closure Strip, No End Caps, W/Back Plates


1,828.8 532.1 907.2 304.8 2,976.3 (kg/m)
P3262 7' 1,390 2,000 12 2,000 Lbs./Ft.
Fiberglass

2,133.6 630.5 907.2 304.8 2,976.3 (kg/m)


System

13
⁄16" P3263 8' 1,560 2,000 12 2,000 Lbs./Ft.
(20.6) 2,438.4 707.6 907.2 304.8 2,976.3 (kg/m)
1 1 ⁄2 " P3264 9' 1,741 2,000 12 2,000 Lbs./Ft.
2 7⁄8" (38.1) 2,743.2 789.7 907.2 304.8 2,976.3 (kg/m)
Special

(73.0)
Metals

1 3⁄8" 12 Ga.
P3265 10' 1,947 2,000 12 2,000 Lbs./Ft.
(34.9) (2.7) 3,048.0 883.1 907.2 304.8 2,976.3 (kg/m)
P3266 12' 2,334 2,000 12 2,000 Lbs./Ft.
1 5 ⁄8 " P3712P 3,657.6 1,058.7 907.2 304.8 2,976.3 (kg/m)
(41.3)
PrimeAngle

P3712P P3267 14' 2,717 2,000 12 2,000 Lbs./Ft.


System

4,267.2 1,232.4 907.2 304.8 2,976.3 (kg/m)


>2" P3268 16' 3,116 2,000 12 2,000 Lbs./Ft.
(>50.8) 4,876.8 1,413.4 907.2 304.8 2,976.3 (kg/m)
P3269 18' 3,530 2,000 12 2,000 Lbs./Ft.
3" 2 7⁄8"
(76.2) (73.0) 5,486.4 1,601.2 907.2 304.8 2,976.3 (kg/m)
Product

P3270 20' 3,882 2,000 12 2,000 Lbs./Ft.


Index

1" 6,096.0 1,760.8 907.2 304.8 2,976.3 (kg/m)


P3704
(25.4)
Safety factor 3.

196 Concrete Inserts


Standard Duty and Accessories

P3165 Series 15⁄8" x 7⁄8" Channel

Channel
15⁄8"
Telestrut
System
Hardware
Nuts &
Anchors 8" (203.2)
On Center
4" 4"
(101.6) (101.6)

General
Fittings
3 3⁄4"
"X" Suffix – No Closure Strip, No End Caps (95.3) A
Load
"WC" Suffix – With Closure Strip & End Caps
B

Pipe/Conduit
Load

Supports
Part Length Wt/100 pcs
Number Ft (M) Lbs (kg) Maximum allowable load/ft.
P3165 10 1,650 A B
3.05 748.4 Concrete Lbs (kg) Lbs (kg)
P3170 20 3,280 Light Weight 425 800

Electrical
Fittings
6.10 1,487.8 192.8 362.9
Safety factor 3. Normal Weight 500 1,000
226.8 453.6
Safety factor 3.

Concrete
Inserts
• Designed for use in prestressed concrete.
• Anchors 8" (203.2 mm) on center; first anchor 4" (101.6 mm) from end.

11⁄4" Framing
• Includes closure and end caps unless otherwise requested.

System
• Material: Cold formed from 12 Ga. (2.7 mm) streel conforming to ASTM A1011 SS GR 33 or
ASTM A653 GR 33. A. Stainless steel available on special order.
• Finish: Choice of Perma-Green II (GR), hot-dipped galvanized (HG) conforming to ASTM A123 or
A153, pre-galvanized (PG) conforming to ASTM A653-G90, or plain (PL).

Framing
System
P2865-10, -15, -20 Hold-Down Springs

13⁄16"
2 7⁄8"
(73.0)

Fiberglass
System
1 5⁄8" Part A Wt/100 pcs
5
⁄8" (41.3) Number In (mm) Lbs (kg)
(15.9) P2865-10 1 2
25.4 0.9
P2865-15 11⁄2 2
Special
Metals

38.1 0.9
P2865-20 2 2
4" 50.8 0.9
(101.6) A
PrimeAngle
System

7
⁄8"
(22.2)

P3712P
Product
Index

Finish: Plain

Concrete Inserts 197


® Light Duty

P3300 Series 15⁄8 x 7⁄8 Channel


Channel
15⁄8"

FM
• when used for sprinkler systems.
P3349 thru P3351
• Includes closure and end caps unless otherwise requested.
• P3380 end cap used when distance to first anchor is up to 2" (50.8 mm).
Telestrut
System

• P3703 end cap is used when end distance to first anchor is over 2" (50.8 mm).
• Nail or anchor inserts to forms every 16" (406 mm) to 24" (610 mm).
• Anchors are 8" (203.2mm) on center.
• Material: Cold formed from 12 Ga. (2.7 mm) steel conforming to
ASTM A1011 SS GR. 33 or A653 GR 33. A. Stainless steel available
Hardware
Nuts &

"NC" Suffix – No Closure Strip, With End Caps on special order.


"WC" Suffix – With Closure Strip & End Caps • Finish: Choice of Perma-Green II (GR), hot-dipped galvanized (HG)
conforming to ASTM A123 or A153, pre-galvanized (PG) conforming
to ASTM A653-G90, or plain (PL).
General
Fittings

Max. Min. Max.


P3352 thru P3353 Insert Wt/100 Allowable Spacing Allowable
Part Length pcs Point Load of Pt. Loads Uniform Load
Number In/Ft. (mm) Lbs (kg) Lbs (kg) In (mm) Lbs (kg)
P3349 3" 68 400 — 400
Pipe/Conduit

76.2 30.8 181.4 181.4


Supports

P3350 4" 81 500 — 500


101.6 36.7 226.8 226.8
P3351 6" 102 750 — 750
152.4 46.3 340.2 340.2
"NC" Suffix – No Closure Strip, With End Caps & Back Plates
P3352 8" 122 1,000 — 1,000
"WC" Suffix – With Closure Strip, End Caps & Back Plates
Electrical

203.2 55.3 453.6 453.6


Fittings

P3353 12" 174 1,500 — 1,500


304.8 78.9 680.4 680.4
P3354 16" 185.0 1,500 12 3,000
406.4 83.9 680.4 304.8 1,360.8
P3354 thru P3370
Concrete
Inserts

P3355 20" 231 1,500 12 3,000


8" 508.0 104.8 680.4 304.8 1,360.8
(203.2) P3356 24" 277 1,500 12 3,000
609.6 125.6 680.4 304.8 1,360.8
P3357 32" 370 1,500 12 1,500 Lbs./Ft.
11⁄4" Framing

812.8 167.8 680.4 304.8 2,232.2 (kg/m)


System

P3357A 36" 416 1,500 12 1,500 Lbs./Ft.


914.4 188.7 680.4 304.8 2,232.2 (kg/m)
P3358 40" 463 1,500 12 1,500 Lbs./Ft.
"NC" Suffix – No Closure Strip, W/End Caps & Back Plates 1,016.0 210.0 680.4 304.8 2,232.2 (kg/m)
"WC" Suffix – W/Closure Strip, End Caps & Back Plates P3359 4' 555 1,500 12 1,500 Lbs./Ft.
⁄16" Framing

"X" – No Closure Strip, No End Caps, W/Back Plates 1,219.2 251.7 680.4 304.8 2,232.2 (kg/m)
System

P3360 5' 694 1,500 12 1,500 Lbs./Ft.


1,524.0 314.8 680.4 304.8 2,232.2 (kg/m)
P3361 6' 832 1,500 12 1,500 Lbs./Ft.
13

1,828.8 377.4 680.4 304.8 2,232.2 (kg/m)


13
⁄16" P3362 7' 971 1,500 12 1,500 Lbs./Ft.
Fiberglass

(20.6) 2,133.6 440.4 680.4 304.8 2,232.2 (kg/m)


System

1 1 ⁄2 " P3363 8' 1,110 1,500 12 1,500 Lbs./Ft.


2 3⁄8" (38.1) 2,438.4 503.5 680.4 304.8 2,232.2 (kg/m)
(60.3) 7⁄8"
12 Ga. P3364 9' 1,249 1,500 12 1,500 Lbs./Ft.
(22.2) (2.7) 2,743.2 566.5 680.4 304.8 2,232.2 (kg/m)
P3365 10' 1,387 1,500 12 1,500 Lbs./Ft.
Special

1 5⁄8"
Metals

P3712P
(41.3) 3,048.0 629.1 680.4 304.8 2,232.2 (kg/m)
P3712P P3366 12' 1,665.0 1,500 12 1,500 Lbs./Ft.
3,657.6 755.2 680.4 304.8 2,232.2 (kg/m)
P3367 14' 1,942 1,500 12 1,500 Lbs./Ft.
PrimeAngle

>2" 4,267.2 880.9 680.4 304.8 2,232.2 (kg/m)


System

(>50.8)
≤2" P3368 16' 2,220 1,500 12 1,500 Lbs./Ft.
2 7⁄16" 2 3⁄8" 1 (≤50.8) 4,876.8 1,007.0 680.4 304.8 2,232.2 (kg/m)
⁄8"
(61.9) (60.3) (3.2) P3369 18' 2,497 1,500 12 1,500 Lbs./Ft.
5,486.4 1,132.6 680.4 304.8 2,232.2 (kg/m)
1"
P3703 P3370 20' 2,775 1,500 12 1,500 Lbs./Ft.
Product

(25.4) P3380
Index

6,096.0 1,258.7 680.4 304.8 2,232.2 (kg/m)

Safety factor 3.

198 Concrete Inserts


Spot Inserts

P3245

Channel
15⁄8"
2 1⁄4"
(57.2)

Telestrut
System
1 5⁄8"
(41.3)

Hardware
Nuts &
2" Square Nut for P3245 Insert
(50.8)
3" Part Size/Thread Wt/100 pcs
(76.2)

General
Fittings
Number In Lbs (kg)
1
P3245-N4 ⁄4" — 20 6
2.7
3
Max. P3245-N6 ⁄8" — 16 5
Wt/100 Allowable 2.3

Pipe/Conduit
Supports
Part pcs Pt. Load HSQN050 1
⁄2" — 13 6
Number Lbs (kg) Lbs (kg) 2.7
P3245 54 1,000 Finish: Electro-galvanized
24.5 453.6

Electrical
Fittings
Finish: Pre-galvanized
Safety factor of 3
• For 1⁄4", 3⁄8", or 1⁄2" size attachment or hanger rod.
• Insert nuts to be ordered separately.

Concrete
Inserts
M24 Spot Insert

2"

11⁄4" Framing
3 3⁄ 4 " (50.8)

System
(When used for (95.3)
FM
sprinkler systems only.) 2 1⁄ 4"
(57.2)

Framing
System
1 5⁄ 8 "
(41.3)
Square Nut for M24

13⁄16"
Part Size/Thread Wt/100 pcs
Number In Lbs (kg)
1

Fiberglass
M2506 ⁄4" — 20 13

System
5.9
Max. M2508 3
⁄8" — 16 14
Wt/100 Allowable 6.4
Part pcs Pt. Load 1
M2510 ⁄2" — 13 14
Number Lbs (kg) Lbs (kg) 6.4
Special
Metals

M24 52 800 M2512 5


⁄8" — 11 12
23.6 362.9 5.4
3
M2523 ⁄4" — 10 11
5.0
PrimeAngle

7
M2524 ⁄8" — 9 10
System

4.5
Finish: Electro-galvanized
Finish: Electro-galvanized
Safety factor of 5
Product
Index

• Ribs along sides of slot give extra strength to case.


• Insert nuts M2506 thru M2524 to be ordered separately.

Concrete Inserts 199


® Deck Inserts

P3700 Series Deck Insert


Channel
15⁄8"
Telestrut
System

13
6" ⁄32"
(152.4) (10.3) HOLE
Hardware

4"
Nuts &

(101.6) Rod Tension Shear


2" 9 Part Diameter Load Load Wt/100 pcs
(50.8) ⁄16"
(14.3) Number In Lbs (kg) Lbs (kg) Lbs (kg)
3
11⁄4" P3700-37 ⁄8 850 600 89
General
Fittings

(31.8) 386 272 40.4


1
P3700-50 ⁄2 1380 1000 111
626 454 50.3
5
P3700-62 ⁄8 1920 1760 141
Pipe/Conduit

871 798 64.0


Supports

Notes:
1. Allowable loads have been determined by the manufacturer’s testing,
analysis, and technical specification.
2. Values are based on a safety factor of 5.
3. 20 Gauge Metal Deck
Electrical
Fittings

2"
Concrete
Inserts

(50.8) SETTING SCREWS

5" 3"
(127.0) (76.2)
11⁄4" Framing

EMBED 6"
System

(152.4)
3"
(76.2)

SHEAR
JAM NUT
⁄16" Framing

OPTIONAL 41⁄2" (76.2)


System

RIB WIDTH
13

TENSION
Fiberglass
System
Special
Metals
PrimeAngle
System
Product
Index

200 Concrete Inserts


Components

P1703, P1704, P3704, P3703 End Cap Anchors

Channel
15⁄8"
Part Channel “A” Wt/100 pcs

Telestrut
System
Number In (mm) Lbs (kg)
P1703 P1000 213⁄32 30
61.1 13.6
P1704 P1000 317⁄32 37
A

Hardware
89.7 16.8

Nuts &
P3703 P3300 27⁄16 17
61.9 7.7
P3704 P3000 3 20
76.2 9.1

General
Fittings
2 7⁄16" P3300 P4703 P4000 23⁄8 27
(61.9) 60.3 12.2

Note: End cap anchor for use with 15⁄8" wide

Pipe/Conduit
standard Unistrut inserts only.

Supports
P2407, P3280, P3380 End Caps

Electrical
Fittings
Part Fits Wt/100 pcs
Number Channel Lbs (kg)
P2407 P1000 10
4.5

Concrete
Inserts
P3280 P3000 8
3.6
P3380 P3300 5
2.3

11⁄4" Framing
System
Framing
System
P3663, P4663 Joint Covers

13⁄16"
Fiberglass
Part Use With Wt/100 pcs

System
Number Insert Series Lbs (kg)
P3663 P3270 10
4.5
P4663 P3370 6
Special
Metals

2.7
1 5⁄8" NOTE: Joint cover for use with 15⁄8" wide
(41.3) standard Unistrut inserts only.
PrimeAngle
System
Product
Index

Note
When used for mechanical supports, load capacities of brackets and fittings should be in compliance with the American Standard Code for Pressure Piping.

Concrete Inserts 201


®
Concrete Inserts Technical Data

Load Chart by Length Spot Insert Load Chart


Channel
15⁄8"

Max. Min. Max. Max. Min. Max.


Allowable Spacing Allowable Allowable Spacing Allowable
Insert Wt/100 Anchor Point Between Uniform Wt/100 Anchor Point Between Uniform
Telestrut
System

Part Length ft Spacing Load Pt. Loads Load Part pcs Spacing Load Pt. Loads Load
Number In (mm) Lbs (kg) In (mm) Lbs (kg) In (mm) Lbs (kg) Number Lbs (kg) In (mm) Lbs (kg) In (mm) Lbs/Ft (kg/m)
P3249 3 85 3 500 – 500 M26/M2812 54 – 1,500 – 1,500
76.2 38.6 76.2 226.8 226.8 24.5 680.4 680.4
P3349 68 3 400 – 400
Hardware

M3245 52 – 1,000 – 1,000


Nuts &

30.8 76.2 181.4 181.4 23.6 453.6 453.6


P3250 4 100 4 800 – 800 M24/M2512 52 – 800 – 800
101.6 45.4 101.6 362.9 362.9 23.6 362.9 362.9
P3350 81 4 500 – 500
General

36.7 101.6 226.8 226.8


Fittings

P3251 6 130 6 1,000 – 1,000 Maximum Allowable Point Load


152.4 59.0 152.4 453.6 453.6
P3351 102 6 750 – 750
46.3 152.4 340.2 340.2 The maximum allowable point load may be
Pipe/Conduit

P3252 8 159 8 1,200 – 1,200


Supports

placed anywhere along the insert.


203.2 72.1 203.2 544.3 544.3 All loads placed less than 2" from the end of
P3352 122 8 1,000 – 1,000 an insert must be reduced by 50%.
55.3 203.2 453.6 453.6 Max. Allowable
Point Load
P3754 12 210 8 2,500 3 5,000
304.8 95.3 203.2 1,134.0 76.2 2,268.0
Electrical
Fittings

P3253 227 4 2,000 – 2,000


103.0 101.6 907.2 907.2 Maximum Allowable Uniform Load
P3353 174 4 1,500 – 1,500
78.9 101.6 680.4 680.4
P3254 16 270 4 2,000 12 4,000
Concrete
Inserts

406.4 122.5 101.6 907.2 304.8 1,814.4 12 in.


P3354 185 4 1,500 12 3,000 Pt. Loads
83.9 101.6 680.4 304.8 1,360.8
P3255 20 357 4 2,000 12 4,000 The maximum allowable uniform
Max. Allowable Uniform Load
508.0 161.9 101.6 907.2 304.8 1,814.4
11⁄4" Framing

load must be placed as a series


System

P3355 231 4 1,500 12 3,000 of point loads.


104.8 101.6 680.4 304.8 1,360.8
P3256 24 399 4 2,000 12 4,000
609.6 181.0 101.6 907.2 304.8 1,814.4 Spacing of Multiple Point Loads
P3356 277 4 1,500 12 3,000
125.6 101.6 680.4 304.8 1,360.8
⁄16" Framing
System

Min. Load Spacing

Continuous Concrete Insert Load Chart Max. Allowable


Pt. Loads
13

Up to 20 Ft. (6.10m)
Max. Allowable Uniform Load
Max. Min. Max.
Fiberglass

Allowable Spacing Allowable


System

Wt/100 Anchor Point Between Uniform


Part ft Spacing Load Pt. Loads Load Pull-Out Load
Number Lbs (kg) In (mm) Lbs (kg) In (mm) Lbs/Ft (kg/m) Minimum Edge Distance to Achieve Rated Pull-Out Capacity
P3270 194 4 2,000 12 2,000 A = 17⁄8" (48mm); P3170
88.0 101.6 907.2 304.8 2,976.3
Special
Metals

3" (76mm); all others


P3370 139 4 1,500 12 1,500
63.0 101.6 680.4 304.8 2,232.2 Insert A
P3170* 165 8 1,000 12 1,000
74.8 203.2 453.6 304.8 1,488.2 A
PrimeAngle
System

*When used in prestressed concrete “T” Beam.


Load data is based on use of 3000 PSI concrete. A

P3712P
Product
Index

202 Concrete Inserts


®
11⁄4" FRAMING SYSTEM
A1000 (14 Gauge) .................................... 206-208
A3300 (14 Gauge) .................................... 209-210
A4000 (19 Gauge) .................................... 211-212
A5000 (14 Gauge) ............................................ 213
Channel Nuts and Closure Strips ........... 214-216
Flat Plate Fittings ..................................... 217-218
Ninety Degree Fittings ............................ 218-220
“Z” Shape Fittings .................................... 220-221
Angle and Wing Shape Fittings ............. 221-222
“U” Shape Fittings ................................... 222-223
Tubing Clips ...................................................... 223
Brackets ............................................................. 224

MATERIAL display markets. It maintains a lightness in scale and a clean


line that makes it aesthetically pleasing as well as functional.
Unistrut channels are accurately and carefully cold formed
to size from low-carbon strip steel. THREADS
STEEL: PLAIN All threads on the nuts and bolts are Unified and American
14 Gauge (1.9 mm), ASTM A1011 SS GR 33 coarse screw threads.
19 Gauge (1.0 mm) ASTM A1008
DESIGN BOLT TORQUE
STEEL: PRE-GALVANIZED
14 Gauge (1.9 mm),
19 Gauge (1.0 mm) ASTM A653 GR 33 BOLT SIZE 1⁄4" - 20 5⁄16" - 18 3⁄8" - 16
Channel nuts are manufactured from mild steel bars con- Rec. Torque 6 11 19
forming to ASTM A576, GR 1015, and are case hardened. Ft/Lbs (N•m) (8) (15) (26)
Fittings are made from hot rolled, pickled and oiled steel Max Torque 7 15 25
Ft/Lbs (N•m) (9) (20) (34)
plate or strip and conform to ASTM A1011 SS GR 33.
Many framing channels are available in special metal on DIMENSIONS
request. Consult factory for ordering information.
Imperial dimensions are illustrated in inches. Metric
FINISHES dimensions are shown in parenthesis or as noted. Unless
All channels and fittings are available in: Perma-Green II noted, all metric dimensions are in millimeters and rounded
(GR), Pre-galvanized (PG), conforming to ASTM A653 GR 33 to one decimal place.
and plain (PL). LOAD DATA
Nuts are available in plain or electro-galvanized (EG) finish. All beam and column load data pertains to carbon steel
Fittings are available in Perma-Green II or plain. and stainless steel channels. Load tables and charts are
constructed to be in accordance with the SPECIFICA-
STANDARD LENGTHS TION FOR THE DESIGN OF COLD-FORMED STEEL
Standard lengths are 10 feet (3.05M) and 20 feet (6.10M). STRUCTURAL MEMBERS 2001 EDITION published by the
Tolerances are: +1⁄8" (3.2 mm) to +1⁄2" (12.7 mm) to allow for AMERICAN IRON AND STEEL INSTITUTE.
cutting. Special lengths are available for a small cutting Type Safety Factor Safety Factor
charge with a tolerance of ± 1⁄8" (3.2mm).
of Load to Yield Strength to Ultimate Strength
APPLICATION Beam Loads 1.67 2.0
1
A framing system designed for medium loads, the 1 ⁄4" series Column Load 1.80 2.2
is especially suitable for use in the OEM, commercial and
203
® 11⁄4" Framing System Pictorial Index

A1000 Series
Channel
15⁄8"

11⁄4" x 11⁄4"
Telestrut
System

14 Ga.
A1000-Pg 206 A1001-Pg 206 A1001 A-Pg 206 A1001 B-Pg 206 A1001 C-Pg 206
Hardware
Nuts &

A3300 Series
General
Fittings

11⁄4" x 3⁄4"
14 Ga.
A3300-Pg 209 A3301-Pg 209
Pipe/Conduit
Supports

A4000 Series
Electrical
Fittings

11⁄4" x 5⁄8"
19 Ga.
A4000-Pg 211 A4001-Pg 211
Concrete
Inserts

A5000 Series
11⁄4" Framing
System

11⁄4" x 21⁄2"
14 Ga.
A5000-Pg 213
Framing
System

Channel Nuts & Closures


13⁄16"
Fiberglass
System

A1006-1420-Pg 215 A4006-1420-Pg 215 A5006-1420-Pg 215 A3006-1420-Pg 215 A3016-0832-Pg 215
Special
Metals
PrimeAngle
System

A1280-Pg 216 A4280-Pg 216 A5280-Pg 216 A1184-Pg 216 A1184P-Pg 216
Product
Index

204 11⁄4" Framing System


11⁄4" Framing System Pictorial Index

A Series Fittings

Channel
15⁄8"
Telestrut
System
A1063-Pg 217 A1065-Pg 217 A1191-Pg Pg 217 A1066-Pg 217 A2324-Pg 217 A1036-Pg 217

Hardware
Nuts &
General
Fittings
A1031-Pg 218 A1026-Pg 218 A1068-Pg 218 A1326-Pg 218 A1458-Pg 218 A1325-Pg 218

Pipe/Conduit
Supports
A1033-Pg 219 A1037-Pg 219 A1038-Pg 219 A1357-Pg 219 A1331-Pg 219 A1332-Pg 219

Electrical
Fittings
Concrete
Inserts
A1579-Pg 220 A2235-Pg 220 A2120-Pg 220 A4120-Pg 220 A5120-Pg 220 A1045-Pg 220

11⁄4" Framing
System
A3345-Pg 222 A4045-Pg 221 A5045-Pg 221 A2109-Pg 221 A2125-Pg 221 A2084-Pg 221

⁄16" Framing
System
13
Fiberglass
System
A2341 R-L-Pg 222 A2472 R-L-Pg 222 A2223-Pg 222 A2345-Pg 222 A2227-Pg 222 A1047-Pg 222

Special
Metals

A3347-Pg 223 A4047-Pg 223 A5047-Pg 223 A5043-Pg 223 A2608-Pg 223 A2491 R-Pg 224
PrimeAngle
System
Product
Index

A2491 L-Pg 224 A2494 R-Pg 224 A2494 L-Pg 224

11⁄4" Framing System 205


® A1000 & A1001 Channels

A1000 – 11⁄4" x 11⁄4" Wt/100 Ft: 104 Lbs(154 kg/100m)


Channel

Allowable Moment 2,170 In-Lbs (240 N•m)


15⁄8"

1 1⁄4" 31.8 14 Gauge Nominal Thickn,ess .075" (1.9mm)


11
9
⁄32" ⁄16" 9
⁄32" 7.1
17.5
7.1
Telestrut
System

.706" 18.0
1 1⁄4" 3
⁄16" 1 31.8 4.8 1
.544" 13.8

2 2
Hardware
Nuts &

A1001 – 11⁄4" x 21⁄2" Wt/100 Ft: 207 Lbs (308 kg/100m)


1
Allowable Moment 6,070 In-Lbs (690 N•m)
1 ⁄4 " 31.8 14 Gauge Nominal Thickness .075" (1.9mm)
General
Fittings

1 1 ⁄4 " 31.8

2 1 ⁄2 " 1 63.5 1
Pipe/Conduit

1 1⁄ 4" 31.8
Supports

2 2

A1001A – 11⁄4" x 21⁄2" Wt/100 Ft: 207 Lbs (308 kg/100m)


Electrical
Fittings

Allowable Moment 7,930 In-Lbs (900 N•m)


1 1 ⁄4 " 31.8 14 Gauge Nominal Thickness .075" (1.9mm)

1 1⁄4" 31.8
Concrete
Inserts

2 1⁄2" 1 63.5 1

1 1⁄4" 31.8
11⁄4" Framing
System

.544 .705 13.9 17.9


2 2

A1001B – 11⁄4" x 21⁄2" Wt/100 Ft: 207 Lbs (308 kg/100m)


Allowable Moment 7,930 In-Lbs (900 N•m)
1 1⁄4" 14 Gauge Nominal Thickness .075" (1.9mm)
31.8
Framing
System

1 1⁄4" 31.8
13⁄16"

2 1⁄2" 1 63.5 1

1 1⁄4" 31.8
Fiberglass
System

.625 .625 15.9 15.9


2 2

A1001C – 11⁄4" x 21⁄2" Wt/100 Ft: 207 Lbs (308 kg/100m)


Special
Metals

Allowable Moment 6,760 In-Lbs (760 N•m)


1 1⁄4" 31.8 14 Gauge Nominal Thickness .075" (1.9mm)

1.290" 32.8
PrimeAngle
System

2 1⁄2" 1 63.5 1

1.210" 30.7
Product

.585 .665 14.9 16.9


Index

2 2

Finishes: PL, GR, HG, PG Standard Lengths: 10' & 20'

206 11⁄4" Framing System


A1000 & A1001 Channels

BEAM LOADING – A1000 BEAM LOADING – A1001

Channel
15⁄8"
Max Defl. at Max Defl. at
Allowable Uniform Uniform Loading at Defl. Allowable Uniform Uniform Loading at Defl.
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360

Telestrut
System
In Lbs In Lbs Lbs Lbs In Lbs In Lbs Lbs Lbs
18 960 0.04 960 960 960 18 1,650 * 0.01 1,650 * 1,650 * 1,650 *
24 720 0.07 720 720 660 24 1,650 * 0.03 1,650 * 1,650 * 1,650 *
36 480 0.16 480 440 300 36 1,350 0.09 1,350 1,350 1,350

Hardware
Nuts &
48 360 0.29 330 250 170 48 1,010 0.16 1,010 1,010 820
60 290 0.45 210 160 110 60 810 0.26 810 790 530
72 240 0.65 150 110 70 72 670 0.37 670 550 370
84 210 0.90 110 80 50 84 580 0.50 540 400 270

General
Fittings
96 180 1.16 80 60 40 96 510 0.66 410 310 210
108 160 1.46 70 50 30 108 450 0.83 330 240 160
120 140 1.75 50 40 30 120 400 1.01 260 200 130

Pipe/Conduit
Supports
COLUMN LOADING – A1000 COLUMN LOADING – A1001

Electrical
Fittings
Maximum Maximum
Unbraced Allowable Load Maximum Column Load Applied at C.G. Unbraced Allowable Load Maximum Column Load Applied at C.G.
Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2

Concrete
In Lbs Lbs Lbs Lbs Lbs In Lbs Lbs Lbs Lbs Lbs

Inserts
18 1,960 5,900 5,430 4,800 4,210 18 3,530 13,300 12,920 12,400 11,880
24 1,840 5,210 4,590 3,850 3,220 24 3,480 12,750 12,220 11,550 10,950
36 1,500 3,940 3,220 2,480 2,010 36 3,370 11,630 10,950 10,220 9,150

11⁄4" Framing
48 1,220 2,950 2,300 1,790 1,460 48 3,260 10,680 10,020 8,260 6,500

System
60 1,020 2,260 1,790 1,400 1,130 60 2,960 9,930 8,260 6,080 4,270
72 880 1,840 1,460 1,130 910 72 2,630 8,480 6,500 4,270 2,970
84 780 1,550 1,230 940 ** 84 2,260 7,040 4,900 3,140 2,180
96 690 1,340 1,050 ** ** 96 1,940 5,680 3,750 2,400 **

⁄16" Framing
108 620 1,170 910 ** ** 108 1,670 4,490 2,970 ** **

System
120 1,440 3,640 2,400 ** **

ELEMENTS OF SECTION

13
A1000/A1001

Fiberglass
System
Notes:
Parameter A1000 A1001
* Load limited by spot weld shear.
Area of Section 0.305 In2 0.609 In2
** KL⁄r > 200
Axis 1-1
1. Above loads include the weight of the member. This weight must be
Moment of Inertia (I) 0.061 In4 0.302 In4
Special
Metals

deducted to arrive at the net allowable load the beam will support.
Section Modulus (S) 0.086 In3 0.242 In3
2. Long span beams should be supported in such a manner as to
Radius of Gyration (r) 0.447 In 0.704 In prevent rotation and twist.
Axis 2-2 3. Allowable uniformly distributed loads are listed for various simple
PrimeAngle

Moment of Inertia (I) 0.078 In4 0.156 In4 spans, that is, a beam on two supports. If load is concentrated at
System

Section Modulus (S) 0.125 In3 0.250 In3 the center of the span, multiply load from the table by 0.5 and
corresponding deflection by 0.8.
Radius of Gyration (r) 0.506 In 0.506 In
Product
Index

11⁄4" Framing System 207


® A1000 & A1001 Channels

BEAM LOADING – A1000 (METRIC) BEAM LOADING – A1001 (METRIC)


Channel
15⁄8"

Max Defl. at Max Defl. at


Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360
Telestrut
System

mm kg mm kg kg kg mm kg mm kg kg kg
600 331 2 331 331 313 600 748 * 1 748 * 748 * 748 *
750 268 3 268 268 200 750 748 * 2 748 * 748 * 748 *
1,000 558 3 558 558 558
Hardware

1,000 200 5 200 168 113


Nuts &

1,250 159 8 145 109 73 1,250 449 4 449 449 354


1,500 132 11 100 73 50 1,500 372 6 372 372 245
1,750 113 15 73 54 36 1,750 322 9 322 272 181
2,000 281 11 277 209 141
General
Fittings

2,000 100 20 54 41 27
2,500 82 32 36 27 18 2,500 222 17 177 132 91
3,000 68 46 23 18 14 3,000 186 25 122 91 64
3,500 159 34 91 68 45
Pipe/Conduit
Supports

COLUMN LOADING – A1000 (METRIC) COLUMN LOADING – A1001 (METRIC)


Electrical
Fittings

Maximum Maximum
Unbraced Allowable Load Max. Column Load Applied at C.G. Unbraced Allowable Load Max. Column Load Applied at C.G.
Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
Concrete

mm kg kg kg kg kg mm kg kg kg kg kg
Inserts

600 839 2,386 2,109 1,769 1,488 600 1,579 5,801 5,561 5,262 4,990
750 762 2,087 1,769 1,424 1,148 750 1,551 5,543 5,262 4,931 4,658
1,000 640 1,647 1,324 1,012 826 1,000 1,515 5,144 4,831 4,472 3,810
11⁄4" Framing

1,250 540 1,302 1,012 789 644 1,250 1,465 4,808 4,472 3,642 2,835
System

1,500 472 1,043 826 644 526 1,500 1,356 4,545 3,810 2,835 2,000
1,750 417 875 694 540 435 1,750 1,234 4,019 3,152 2,114 1,470
2,000 372 753 599 463 ** 2,000 1,102 3,479 2,531 1,619 1,125
2,250 336 662 526 399 ** 2,250 966 2,953 2,000 1,279 **
Framing

2,500 304 590 463 ** ** 2,500 853 2,454 1,619 1,039 **


System

2,750 277 526 408 ** ** 2,750 753 2,028 1,338 ** **


13⁄16"

ELEMENTS OF SECTION
A1000/A1001 (METRIC)
Fiberglass
System

Notes:
Parameter A1000 A1001
* Load limited by spot weld shear.
Area of Section 1.96 cm2 3.93 cm2
** KL⁄r > 200
Axis 1-1
1. Above loads include the weight of the member. This weight must be
2.53 cm4 12.57 cm4
Special

Moment of Inertia (I)


Metals

deducted to arrive at the net allowable load the beam will support.
Section Modulus (S) 1.41 cm3 3.96 cm3 2. Long span beams should be supported in such a manner as to
Radius of Gyration (r) 1.14 cm 1.79 cm prevent rotation and twist.
Axis 2-2 3. Allowable uniformly distributed loads are listed for various simple
PrimeAngle

Moment of Inertia (I) 3.25 cm4 6.50 cm4 spans, that is, a beam on two supports. If load is concentrated at
System

Section Modulus (S) 2.05 cm3 4.09 cm3 the center of the span, multiply load from the table by 0.5 and
corresponding deflection by 0.8.
Radius of Gyration (r) 1.29 cm 1.29 cm
Product
Index

208 11⁄4" Framing System


A3300 & A3301 Channels

A3300 – 11⁄4" x 3⁄4" A3301 – 11⁄4" x 11⁄2"

Channel
15⁄8"
Wt/100 Ft: 78 Lbs (116 kg/100m) Wt/100 Ft: 156 Lbs (232 kg/100m)
Allowable Moment 950 In-Lbs (110 N•m) Allowable Moment 2,590 In-Lbs (290 N•m)
14 Gauge Nominal Thickness .075" (1.9mm) 14 Gauge Nominal Thickness .075" (1.9mm)

Telestrut
System
Hardware
Nuts &
1 1⁄4"
11
⁄16" 31.8 1 1⁄4"
9
⁄32" 9
⁄32" 7.1 17.5 7.1 31.8
3
⁄16" .440"
4.8 11.2

General
Fittings
3
⁄4"
19.1
3
⁄4" 1 1 1⁄2" 1
19.1 38.1 1
1 3
⁄4 " 19.1
2 .310" 2
2

Pipe/Conduit
2 7.9

Supports
BEAM LOADING – A3300 BEAM LOADING – A3301
Max Defl. at Max Defl. at
Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360

Electrical
Fittings
In Lbs In Lbs Lbs Lbs In Lbs In Lbs Lbs Lbs
18 420 0.07 420 420 320 18 990 * 0.03 990 * 990 * 990 *
24 320 0.12 320 270 180 24 860 0.07 860 860 850
36 210 0.26 160 120 80 36 580 0.15 580 560 380

Concrete
Inserts
48 160 0.47 90 70 50 48 430 0.27 420 320 210
60 130 0.75 60 40 30 60 350 0.43 270 200 140
72 110 1.09 40 30 20 72 290 0.62 190 140 90
84 90 1.42 30 20 10 84 250 0.85 140 100 70

11⁄4" Framing
96 80 1.88 20 20 10 96 220 1.11 110 80 50

System
COLUMN LOADING – A3300 COLUMN LOADING – A3301
Maximum Maximum
Unbraced Allowable Load Max. Column Load Applied at C.G. Unbraced Allowable Load Max. Column Load Applied at C.G.

⁄16" Framing
System
Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
In Lbs Lbs Lbs Lbs Lbs In Lbs Lbs Lbs Lbs Lbs
18 1,430 4,490 4,210 3,860 3,550 18 2,540 9,890 9,620 9,300 9,020

13
24 1,370 4,090 3,750 3,310 2,680 24 2,510 9,510 9,200 8,710 7,960
36 1,190 3,390 2,680 1,820 1,260 36 2,410 8,800 7,960 6,730 5,490

Fiberglass
System
48 900 2,380 1,600 1,020 ** 48 2,230 7,560 6,320 4,690 3,310
60 680 1,550 1,020 ** ** 60 1,970 6,210 4,690 3,050 2,120
72 1,650 4,890 3,310 2,120 **
ELEMENTS OF SECTION - A3300/A3301 84 1,380 3,680 2,430 ** **
Special
Metals

96 1,160 2,820 1,860 ** **


Parameter A3300 A3301
Area of Section 0.230 In2 0.459 In2 Notes:
Axis 1-1 * Load limited by spot weld shear.
PrimeAngle

** KL⁄r > 200


Moment of Inertia (I) 0.017 In4 0.077 In4
System

Section Modulus (S) 0.038 In3 0.103 In3 1. Above loads include the weight of the member. This weight must be
deducted to arrive at the net allowable load the beam will support.
Radius of Gyration (r) 0.269 In 0.411 In
2. Long span beams should be supported in such a manner as to
Axis 2-2 prevent rotation and twist.
Moment of Inertia (I) 0.052 In4 0.104 In4
Product

3. Allowable uniformly distributed loads are listed for various simple


Index

Section Modulus (S) 0.083 In3 0.167 In3 spans, that is, a beam on two supports. If load is concentrated at the
Radius of Gyration (r) 0.477 In 0.477 In center of the span, multiply load from the table by 0.5 and corre-
sponding deflection by 0.8.
11⁄4" Framing System 209
® A3300 & A3301 Channels

BEAM LOADING – A3300 (METRIC) BEAM LOADING – A3301 (METRIC)


Channel
15⁄8"

Max Defl. at Max Defl. at


Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360
Telestrut
System

mm kg mm kg kg kg mm kg mm kg kg kg
600 145 3 145 127 86 600 399 2 399 399 395
750 118 5 109 82 54 750 318 3 318 318 254
1,000 86 8 59 45 32 1,000 240 5 240 213 141
Hardware
Nuts &

1,250 68 12 41 27 18 1,250 191 7 181 136 91


1,500 59 18 27 18 14 1,500 159 10 127 95 64
1,750 50 24 18 14 9 1,750 136 14 95 68 45
2,000 45 33 14 14 9 2,000 118 18 73 54 36
General
Fittings

2,500 95 29 45 36 23
3,000 82 43 32 23 14
Pipe/Conduit

COLUMN LOADING – A3300 (METRIC) COLUMN LOADING – A3301 (METRIC)


Supports

Maximum Maximum
Unbraced Allowable Load Max. Column Load Applied at C.G. Unbraced Allowable Load Max. Column Load Applied at C.G.
Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
mm kg kg kg kg kg mm kg kg kg kg kg
Electrical
Fittings

600 621 1,864 1,715 1,524 1,243 600 1,139 4,323 4,182 3,978 3,642
750 594 1,701 1,524 1,175 853 750 1,125 4,173 3,978 3,556 3,098
1,000 503 1,406 1,061 689 481 1,000 1,075 3,842 3,406 2,790 2,182
Concrete

1,250 399 1,034 689 440 ** 1,250 1,002 3,366 2,790 2,041 1,429
Inserts

1,500 318 726 481 ** ** 1,500 907 2,867 2,182 1,429 993
1,750 785 2,368 1,637 1,048 **
2,000 680 1,901 1,256 803 **
11⁄4" Framing

2,250 590 1,501 993 ** **


System

2,500 513 1,216 803 ** **

ELEMENTS OF SECTION
Framing
System

A3300/A3301 (METRIC)
13⁄16"

Parameter A3300 A3301 Notes:


2 2 * Load limited by spot weld shear.
Area of Section 1.48 cm 2.96 cm
** KL⁄r > 200
Axis 1-1
Fiberglass
System

Moment of Inertia (I) 0.69 cm4 3.22 cm4 1. Above loads include the weight of the member. This weight must be
deducted to arrive at the net allowable load the beam will support.
Section Modulus (S) 0.62 cm3 1.69 cm3
2. Long span beams should be supported in such a manner as to
Radius of Gyration (r) 0.68 cm 1.04 cm prevent rotation and twist.
Axis 2-2 3. Allowable uniformly distributed loads are listed for various simple
Special

2.17 cm4 4.34 cm4


Metals

Moment of Inertia (I) spans, that is, a beam on two supports. If load is concentrated at the
Section Modulus (S) 1.37 cm3 2.73 cm3 center of the span, multiply load from the table by 0.5 and corre-
Radius of Gyration (r) 1.21 cm 1.21 cm sponding deflection by 0.8.
PrimeAngle
System
Product
Index

210 11⁄4" Framing System


A4000 & A4001 Channels

A4000 – 11⁄4" x 5⁄8" A4001– 11⁄4" x 11⁄4"

Channel
15⁄8"
Wt/100 Ft: 45 Lbs (67 kg/100m) Wt/100 Ft: 90 Lbs (134 kg/100m)
Allowable Moment 560 In-Lbs (60 N•m) Allowable Moment 1,470 In-Lbs (170 N•m)
19 Gauge Nominal Thickness .040" (1.0mm) 19 Gauge Nominal Thickness .040" (1.0mm)

Telestrut
System
Hardware
Nuts &
1 1⁄ 4 " 31.8
1 1⁄4" 31.8
11
⁄16" 17.5 5 15.9
9
⁄32" 9
⁄32" 7.1 7.1 ⁄8"
3
⁄16" .363" 4.8 9.2

General
1

Fittings
1 1⁄4" 1 31.8
5 1
⁄ 8" 1 15.9

5
.262" 2 6.7 ⁄8" 2 15.9 2
2

Pipe/Conduit
BEAM LOADING – A4000 BEAM LOADING – A4001

Supports
Max Defl. at Max Defl. at
Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360
In Lbs In Lbs Lbs Lbs In Lbs In Lbs Lbs Lbs

Electrical
Fittings
18 250 0.08 250 220 150 18 350 * 0.02 350 * 350 * 350 *
24 190 0.15 170 120 80 24 350 * 0.06 350 * 350 * 350 *
36 120 0.32 70 60 40 36 330 0.19 330 270 180

Concrete
48 90 0.58 40 30 20 48 240 0.32 200 150 100

Inserts
60 70 0.88 30 20 10 60 200 0.52 130 100 60
72 60 1.30 20 10 10 72 160 0.72 90 70 40
84 140 1.00 70 50 30

11⁄4" Framing
System
COLUMN LOADING – A4000 COLUMN LOADING – A4001
Maximum Maximum
Unbraced Allowable Load Max. Column Load Applied at C.G. Unbraced Allowable Load Max. Column Load Applied at C.G.
Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2

⁄16" Framing
In Lbs Lbs Lbs Lbs Lbs In Lbs Lbs Lbs Lbs Lbs

System
18 880 2,510 2,290 1,990 1,700 18 1,640 5,640 5,420 5,110 4,800
24 880 2,190 1,890 1,530 1,230 24 1,600 5,320 5,000 4,600 4,240

13
36 670 1,570 1,230 830 580 36 1,510 4,650 4,240 3,500 2,730
48 470 1,110 730 470 ** 48 1,330 4,030 3,240 2,250 1,560

Fiberglass
System
60 340 710 470 ** ** 60 1,090 3,170 2,250 1,440 1,000
72 870 2,370 1,560 1,000 **
ELEMENTS OF SECTION 84 700 1,740 1,150 ** **
A4000/A4001
Special
Metals

Notes:
Parameter A4000 A4001
2 2
* Load limited by spot weld shear.
Area of Section 0.132 In 0.264 In
** KL⁄r > 200
Axis 1-1
PrimeAngle

Moment of Inertia (I) 0.008 In4 0.037 In4 1. Above loads include the weight of the member. This weight must be
System

deducted to arrive at the net allowable load the beam will support.
Section Modulus (S) 0.022 In3 0.058 In3
2. Long span beams should be supported in such a manner as to
Radius of Gyration (r) 0.240 In 0.372 In prevent rotation and twist.
Axis 2-2 3. Allowable uniformly distributed loads are listed for various simple
Moment of Inertia (I) 0.029 In4 0.058 In4 spans, that is, a beam on two supports. If load is concentrated at the
Product
Index

Section Modulus (S) 0.046 In3 0.093 In3 center of the span, multiply load from the table by 0.5 and corre-
sponding deflection by 0.8.
Radius of Gyration (r) 0.469 In 0.469 In

11⁄4" Framing System 211


® A4000 & A4001 Channels

BEAM LOADING – A4000 (METRIC) BEAM LOADING – A4001 (METRIC)


Channel
15⁄8"

Max Defl. at Max Defl. at


Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360
Telestrut
System

mm kg mm kg kg kg mm kg mm kg kg kg
600 86 4 77 59 41 600 159 * 1 159 * 159 * 159 *
750 68 6 50 36 27 750 159 * 3 159 * 159 * 118
1,000 50 10 27 23 14 1,000 136 6 136 100 68
Hardware
Nuts &

1,250 41 16 18 14 9 1,250 109 9 86 64 41


1,500 36 24 14 9 5 1,500 91 13 59 45 32
1,750 77 17 45 32 23
2,000 68 22 32 27 18
General
Fittings
Pipe/Conduit
Supports

COLUMN LOADING – A4000 (METRIC) COLUMN LOADING – A4001 (METRIC)


Maximum Maximum
Electrical
Fittings

Unbraced Allowable Load Max. Column Load Applied at C.G. Unbraced Allowable Load Max. Column Load Applied at C.G.
Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
mm kg kg kg kg kg mm kg kg kg kg kg
Concrete

600 399 1,002 866 708 572 600 726 2,422 2,282 2,100 1,937
Inserts

750 354 857 708 540 390 750 708 2,272 2,100 1,901 1,615
1,000 281 649 494 318 218 1,000 671 2,028 1,810 1,420 1,052
1,250 209 481 318 ** ** 1,250 590 1,787 1,420 971 676
11⁄4" Framing

1,500 154 331 218 ** ** 1,500 503 1,470 1,052 676 467
System

1,750 417 1,166 776 494 **


2,000 349 898 594 ** **
2,250 295 708 467 ** **
Framing

ELEMENTS OF SECTION
System

A4000/A4001 (METRIC)
13⁄16"

Notes:
Parameter A4000 A4001
* Load limited by spot weld shear.
Area of Section 0.85 cm2 1.70 cm2
Fiberglass

** KL⁄r > 200


System

Axis 1-1
1. Above loads include the weight of the member. This weight must be
Moment of Inertia (I) 0.32 cm4 1.52 cm4
deducted to arrive at the net allowable load the beam will support.
Section Modulus (S) 0.37 cm3 0.96 cm3
2. Long span beams should be supported in such a manner as to
Radius of Gyration (r) 0.61 cm 0.94 cm prevent rotation and twist.
Special
Metals

Axis 2-2 3. Allowable uniformly distributed loads are listed for various simple
Moment of Inertia (I) 1.21 cm4 2.42 cm4 spans, that is, a beam on two supports. If load is concentrated at the
Section Modulus (S) 0.76 cm3 1.52 cm3 center of the span, multiply load from the table by 0.5 and corre-
sponding deflection by 0.8.
Radius of Gyration (r) 1.19 cm 1.19 cm
PrimeAngle
System
Product
Index

212 11⁄4" Framing System


A5000 Channels

A5000 – 11⁄4" x 21⁄2" 1 1⁄4" 31.8 Wt/100 Ft: 167 Lbs (249 kg/100m)

Channel
11
⁄16" 17.5 Allowable Moment 6,670 In-Lbs (750 N•m)
9

15⁄8"
⁄32" 9
⁄32" 7.1 7.1 14 Gauge Nominal Thickness .075" (1.9mm)

Telestrut
System
3 1.349"
⁄16" 4.8 34.3
2 1⁄2" 1 63.5 1
1.151" 29.2

Hardware
Nuts &
2 2

BEAM LOADING – A5000 BEAM LOADING – A5000 (METRIC)

General
Fittings
Max Defl. at Max Defl. at
Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360

Pipe/Conduit
In Lbs Lbs Lbs Lbs Lbs mm kg mm kg kg kg

Supports
24 2,220 0.04 2,220 2,220 2,220 600 1,025 1 1,025 1,025 1,025
36 1,480 0.09 1,480 1,480 1,480 750 821 1 821 821 821
48 1,110 0.15 1,110 1,110 980 1,000 617 3 617 617 617
60 890 0.24 890 890 630 1,250 490 4 490 490 422

Electrical
Fittings
72 740 0.34 740 650 430 1,500 408 6 408 408 295
84 640 0.47 640 480 320 1,750 349 8 349 322 213
96 560 0.61 490 370 240 2,000 308 10 308 249 163
108 490 0.76 390 290 190 2,500 245 16 213 159 104

Concrete
Inserts
120 440 0.94 310 230 160 3,000 204 23 145 109 73

COLUMN LOADING – A5000 COLUMN LOADING – A5000 (METRIC)


Maximum Maximum

11⁄4" Framing
System
Unbraced Allowable Load Max. Column Load Applied at C.G. Unbraced Allowable Load Max. Column Load Applied at C.G.
Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
In Lbs Lbs Lbs Lbs Lbs mm kg kg kg kg kg
24 2,790 7,950 6,670 5,080 3,760 600 1,275 3,647 3,075 2,359 1,751
36 1,950 5,270 3,760 2,600 1,970 750 1,089 3,025 2,359 1,633 1,211

⁄16" Framing
System
48 1,360 3,290 2,350 1,690 1,330 1,000 794 2,091 1,465 1,025 785
60 990 2,300 1,690 1,260 1,010 1,250 594 1,429 1,025 744 585
72 790 1,750 1,330 1,010 830 1,500 463 1,066 785 585 467

13
84 660 1,420 1,100 860 710 1,750 376 848 635 485 395
96 570 1,200 940 740 ** 2,000 322 703 540 417 340

Fiberglass
System
108 510 1,040 830 ** ** 2,250 281 603 467 367 304
120 460 930 740 ** ** 2,500 254 531 417 327 **

ELEM. OF SECTION A5000 ELEM. OF SECTION A5000 (METRIC) Notes:


Special
Metals

Parameter A5000 Parameter A5000 * Load limited by spot weld shear.


Area of Section 0.492 In2 Area of Section 3.17 cm2 ** KL⁄r > 200
Axis 1-1 Axis 1-1 1. Above loads include the weight of the member.
PrimeAngle

Moment of Inertia (I) 0.358 In4 Moment of Inertia (I) 14.91 cm4 This weight must be deducted to arrive at the net
System

allowable load the beam will support.


Section Modulus (S) 0.265 In3 Section Modulus (S) 4.35 cm3
2. Long span beams should be supported in such a
Radius of Gyration (r) 0.853 In Radius of Gyration (r) 2.17 cm manner as to prevent rotation and twist.
Axis 2-2 Axis 2-2 3. Allowable uniformly distributed loads are listed
Moment of Inertia (I) 0.143 In4 Moment of Inertia (I) 5.94 cm4 for various simple spans, that is, a beam on two
Product

0.229 In3 3.74 cm3 supports. If load is concentrated at the center of


Index

Section Modulus (S) Section Modulus (S)


the span, multiply load from the table by 0.5 and
Radius of Gyration (r) 0.539 In Radius of Gyration (r) 1.37 cm
corresponding deflection by 0.8.

11⁄4" Framing System 213


® Nut Selection and Load Data

LOAD DATA FOR UNISTRUT SECTIONS SUBJECT TO CRUSHING LOADS


Channel
15⁄8"

Allowable Load Allowable Load


LOAD
LOAD at Center of Member at End of member
Channel Lbs (kg) Channel Lbs (kg)
Telestrut
System

Channel A1000 3,000 A1000 2000


Channel
1,361 907
listed. listed.
A3300 3,000 A3300 2000
1,361 907
Hardware

A4000 1,400 A4000 1000


Nuts &

635 454
A5000 2,500 A5000 1800
1,134 816
Safety Factor of 21⁄2 Safety Factor of 21⁄2
General
Fittings

Maximum Allowable Pull-Out And Slip Loads


Pipe/Conduit
Supports

Max. Allowable Resistance


Nut Size/ Pull-Out to Slip Torque
Thread Channel Gauge Lbs (kg) Lbs (kg) Ft-Lbs (N•m)
3
⁄8" -16 A1000 14 900 500 19
408 227 26
5
⁄16" -18 A3300 14 900 500 11
Electrical
Fittings

408 227 15
1
⁄4" -20 A5000 14 900 500 6
408 227 8
3
⁄8" -16 A4000 19 300 400 19
136 181 26
Concrete
Inserts

Nut design loads include a minimum safety factor of 3.

Nut Selections Chart


11⁄4" Framing
System

Channel Nut Nut Size – Thread Use with Channel


Part Number In. - Thread A1000 A3300 A4000 A5000
A1006-1420 1
⁄4" – 20 ■ - - -
Framing

A1007 5
⁄16" – 18 ■ - - -
System

A1008 3
⁄8" – 16 ■ - - -
13⁄16"

A3006-1420 1
⁄4" – 20 ■ ■ ■ ■
A3007 5
⁄16" – 18 ■ ■ ■ ■
Fiberglass

A3008 3
⁄8" – 16 ■ ■ ■ ■
System

A3016-0832 #8 – 32 ■ ■ ■ ■
A3016-1024 #10 – 24 ■ ■ ■ ■
A3016-1032 #10 – 32 ■ ■ ■ ■
Special
Metals

A3016-1420 1
⁄4" – 20 ■ ■ ■ ■
A4006-1420 1
⁄4" – 20 - ■ ■ -
A4007 5
⁄16" – 18 - ■ ■ -
PrimeAngle

3
■ ■
System

A4008 ⁄8" – 16 - -
A5006-1420 1
⁄4" – 20 - - - ■
A5007 5
⁄16" – 18 - - - ■
A5008 3
⁄8" – 16 - - - ■
Product
Index

214 11⁄4" Framing System


Unistrut Nuts

A1006-1420, A1007, A1008 A4006-1420, A4007, A4008

Channel
15⁄8"
Channel Nuts with Springs Channel Nuts with Springs

Telestrut
Part Thread Size Wt/100 pcs Part Thread Size Wt/100 pcs

System
Number In Lbs (kg) Number In Lbs (kg)
1 1
A1006-1420 ⁄4"-20 6 A4006-1420 ⁄4"-20 5
2.7 2.3
5 5
A1007 ⁄16"-18 6 A4007 ⁄16"-18 5

Hardware
Nuts &
2.7 2.3
3 3
A1008 ⁄8"-16 6 A4008 ⁄8"-16 5
2.7 2.3
Note: Use with A1000 channel. Note: Use with A3300 & A4000 channels.

General
Fittings
Pipe/Conduit
Supports
A5006-1420, A5007, A5008 A3006-1420, A3007, A3008
Channel Nuts with Springs Channel Nuts without Springs

Electrical
Fittings
Part Thread Size Wt/100 pcs Part Thread Size Wt/100 pcs
Number In Lbs (kg) Number In Lbs (kg)
1 1
A5006-1420 ⁄4"-20 6 A3006-1420 ⁄4"-20 5
2.7 2.3

Concrete
Inserts
5 5
A5007 ⁄16"-18 6 A3007 ⁄16"-18 5
2.7 2.3
3 3
A5008 ⁄8"-16 6 A3008 ⁄8"-16 5
2.7 2.3

11⁄4" Framing
Note: Use with A5000 channel.
Note: Use with A1000, A3300,

System
A4000 & A5000 channels.

⁄16" Framing
System
A3016-0832 thru A3016-1420 Channel Nuts without Springs

13
Fiberglass
System
Part Thread Size Wt/100 pcs
Number In Lbs (kg)
A3016-0832 #8 - 32 1
0.5
Special
Metals

A3016-1024 #10 - 24 1
0.5
A3016-1032 #10 - 32 1
0.5
PrimeAngle

1
System

A3016-1420 ⁄4" - 20 1
0.5

Note: Use with A1000, A3300, A4000 & A5000 channels.


Product
Index

11⁄4" Framing System 215


® Channel End Caps and Closure Strips

A1280 End Cap A4280 End Cap


Channel

Wt/100 pcs: 7 Lbs (3.2 kg) Wt/100 pcs: 3 Lbs (1.4 kg)
15⁄8"
Telestrut
System
Hardware
Nuts &
General
Fittings

Material: .075" (1.9) Material: .075" (1.9)


Note: Use with A1000 channel Note: Use with A4000 channel.
Pipe/Conduit
Supports

A5280 End Cap A1184 Closure Strip


Wt/100 pcs: 14 Lbs (6.4 kg) Wt/100 Ft: 21 Lbs (31.3 kg/100M)
Electrical
Fittings

.020"
(0.5)
Concrete
Inserts
11⁄4" Framing
System

1 1 ⁄4 "
(31.8)
Material: .075" (1.9)
Note: Use with A5000 channel.
Standard Length 10 Feet.
Finish: Perma-Green II (GR), Plain (PL).
Framing
System

A1184P Closure Strip


Wt/100 Ft: 21 Lbs (31.3 kg/100M)
13⁄16"
Fiberglass
System

3
⁄32"
(2.4)
Special
Metals
PrimeAngle

1"
System

(25.4)

Standard length: 10 Ft.


Material: Paintable PVC.
Product

Color: Green, Grey.


Index

216 11⁄4" Framing System


Flat Plate Fittings

A1063 Wt/100 pcs: 8 Lbs (3.6 kg) A1065 Wt/100 pcs: 17 Lbs (7.7 kg)

Channel
15⁄8"
Telestrut
2 3⁄4"

System
1 1⁄4" (69.9)
(31.8)

Hardware
Nuts &
General
Fittings
Pipe/Conduit
Supports
A1191 Wt/100 pcs: 87 Lbs (39.5 kg) A1066 Wt/100 pcs: 26 Lbs (11.8 kg)

Electrical
Fittings
4 1⁄4"
(108.0)

13 1⁄4"

Concrete
Inserts
(336.6)

11⁄4" Framing
System
⁄16" Framing
System
A2324 Wt/100 pcs: 39 Lbs (17.7 kg) A1036 Wt/100 pcs: 27 Lbs (12.2 kg)

13
2 3 ⁄4 "

Fiberglass
System
(69.9)

5 3⁄4"
(146.1) 2 3 ⁄4 "
(69.9)
Special
Metals

3"
(76.2)
PrimeAngle
System
Product
Index

Standard Dimensions for 11⁄4" (32 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄32" (10.3mm); Hole Spacing - From End: 5⁄8" (15.9 mm); Hole Spacing - On Center: 11⁄2" (38.1 mm); Width: 11⁄4"(31.8mm); Thickness: 3⁄16" (4.8mm)
13

11⁄4" Framing System 217


® Flat Plate and Ninety Degree Fittings

A1031 Wt/100 pcs: 34 Lbs (15.4 kg) A1026 Wt/100 pcs: 17 Lbs (7.7 kg)
Channel
15⁄8"

4 1⁄4"
Telestrut
System

(108.0)
1 19⁄32"
(40.5)
2 3 ⁄4 "
(69.9)
Hardware
Nuts &

1 7⁄16"
(36.5)
General
Fittings
Pipe/Conduit
Supports

A1068 Wt/100 pcs: 17 Lbs (7.7 kg) A1326 Wt/100 pcs: 27 Lbs (12.2 kg)

1 1⁄ 4"
Electrical

(31.8)
Fittings

1 1⁄4"
(31.8)
Concrete
Inserts

3 9⁄32"
(83.3)
1 25/32"
(45.2)
11⁄4" Framing
System
Framing
System

A1458 Wt/100 pcs: 27 Lbs (12.2 kg) A1325 Wt/100 pcs: 38 Lbs (17.2 kg)
13⁄16"
Fiberglass

2 3⁄4" 2 3⁄4"
System

(69.9) (69.9)

1 25⁄32"
(45.2)
3 9⁄32"
(83.3)
Special
Metals
PrimeAngle
System
Product
Index

Standard Dimensions for 11⁄4" (32 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄32" (10.3mm); Hole Spacing - From End: 5⁄8" (15.9 mm); Hole Spacing - On Center: 11⁄2" (38.1 mm); Width: 11⁄4"(31.8mm); Thickness: 3⁄16" (4.8mm)
13

218 11⁄4" Framing System


Ninety Degree Fittings

A1033 Wt/100 pcs: 34 Lbs (15.4 kg) A1037 Wt/100 pcs: 30 Lbs (13.6 kg)

Channel
15⁄8"
2 3⁄ 4 "
(69.9)

Telestrut
System
119⁄32"
(40.5)
4 1⁄4"
(108.0)

Hardware
Nuts &
General
Fittings
1 19⁄32"
(40.5)

Pipe/Conduit
Supports
A1038 Wt/100 pcs: 30 Lbs (13.6 kg) A1357 Wt/100 pcs: 30 Lbs (13.6 kg)

Electrical
Fittings
2 3⁄ 4 "
(69.9)
2 1⁄2"
(63.5)

Concrete
Inserts
125⁄32"
(45.2)

11⁄4" Framing
System
1 19⁄32"
(40.5) 1 1⁄4"
(31.8)

⁄16" Framing
System
A1331 Wt/100 pcs: 75 Lbs (34.0 kg) A1332 Wt/100 pcs: 75 Lbs (34.0 kg)

13
2 3⁄4" 2 3⁄4"

Fiberglass
(69.9)

System
(69.9)

3 9⁄32"
(83.3) 3 9⁄32"
5
(83.3)
1 ⁄32" 1 5⁄32"
Special
Metals

(29.4)
(29.4)
PrimeAngle
System
Product
Index

Standard Dimensions for 11⁄4" (32 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄32" (10.3mm); Hole Spacing - From End: 5⁄8" (15.9 mm); Hole Spacing - On Center: 11⁄2" (38.1 mm); Width: 11⁄4"(31.8mm); Thickness: 3⁄16" (4.8mm)
13

11⁄4" Framing System 219


® Ninety Degree and "Z" Shape Fittings

A1579 Wt/100 pcs: 44 Lbs (20.0 kg) A2235 Wt/100 pcs: 59 Lbs (26.8 kg)
Channel
15⁄8"

2 3⁄4"
(69.9)
Telestrut
System

2 3⁄4"
(69.9)
3 9⁄32"
125⁄32" (83.3)
(45.2)
Hardware
Nuts &
General
Fittings

1 1⁄4" 1 1⁄4"
(31.8) (31.8)
Pipe/Conduit
Supports

A2120 Wt/100 pcs: 9 Lbs (4.1 kg) A4120 Wt/100 pcs: 7 Lbs (3.2 kg)
Electrical
Fittings

3
3
⁄16" (4.8) Hole ⁄16" (4.8) Hole
3 3
1 ⁄8" ⁄4"
(34.9) (19.1)
Concrete
Inserts

13
⁄16"
(20.6) A4000
13
⁄16" A1000
(20.6)
1 15⁄16"
11⁄4" Framing

1 15⁄16" (49.2)
(49.2)
System

1
⁄8" (3.2) Thick 1
⁄8" (3.2) Thick
Framing
System

A5120 Wt/100 pcs: 13 Lbs (5.9 kg) A1045 Wt/100 pcs: 25 Lbs (11.3 kg)
13⁄16"

3
⁄16" (4.8) Hole 2 7⁄8"
Fiberglass

(73.0)
System

1 7⁄16"
2 5⁄8" (36.5)
(66.7)

A1000
Special
Metals

13
⁄16"
(20.6) A5000
1 1⁄4"
(31.8)
PrimeAngle

15
1 ⁄16"
System

(49.2) 1
⁄8" (3.2) Thick
Product
Index

Standard Dimensions for 11⁄4" (32 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄32" (10.3mm); Hole Spacing - From End: 5⁄8" (15.9 mm); Hole Spacing - On Center: 11⁄2" (38.1 mm); Width: 11⁄4"(31.8mm); Thickness: 3⁄16" (4.8mm)
13

220 11⁄4" Framing System


"Z", Angular and Wing Shape Fittings

A3345 Wt/100 pcs: 23 Lbs (10.4 kg) A4045 Wt/100 pcs: 21 Lbs (9.5 kg)

Channel
15⁄8"
2 7⁄8"

Telestrut
System
(73.0)
2 7⁄8"
(73.0)

1 7⁄16" 1 7⁄16"
(36.5) (36.5)

Hardware
Nuts &
5
3
⁄4" A4000 ⁄8"
A3300 (19.1) (15.9)

General
Fittings
Pipe/Conduit
Supports
A5045 Wt/100 pcs: 33 Lbs (15.0 kg) A2109, A2110, A2111 Wt/100 pcs: 23 Lbs (10.4 kg)

A
2 7⁄8" 2 1⁄4"

Electrical
(57.2)

Fittings
(73.0)

A5000
B

Concrete
Inserts
Part A B
Number Degree (rad) In (mm)

11⁄4" Framing
2 1⁄2"
(63.5) A2109 521⁄2° 125⁄32

System
0.92 45.2
A2110 45° 13⁄4
0.79 44.5
A2111 371⁄2° 13⁄4
0.65 44.5

⁄16" Framing
System
A2125, A2126, A2127 Wt/100 pcs: 17 Lbs (7.7 kg) A2084 Wt/100 pcs: 90 Lbs (40.8 kg)

13
1 1⁄4"
(31.8)

Fiberglass
System
1 7⁄16"
(36.5) 2 15⁄16"
B (74.6) 2 21⁄32"
(67.5)
Special
Metals

Part A B
Number Degree (rad) In (mm)
A2125 521⁄2° 11⁄4
PrimeAngle

0.92 31.8
System

A2126 45° 11⁄4


0.79 31.8 1 1⁄4"
(31.8)
A2127 371⁄2° 19⁄32
0.65 32.5
Product
Index

Standard Dimensions for 11⁄4" (32 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄32" (10.3mm); Hole Spacing - From End: 5⁄8" (15.9 mm); Hole Spacing - On Center: 11⁄2" (38.1 mm); Width: 11⁄4"(31.8mm); Thickness: 3⁄16" (4.8mm)
13

11⁄4" Framing System 221


® Wing and "U" Shape Fittings

A2341 R-L Wt/100 pcs: 26 Lbs (11.8 kg) A2472 R-L Wt/100 pcs: 33 Lbs (15.0 kg)
Channel
15⁄8"

1 7⁄16" 1 7⁄16"
(36.5)
Telestrut
System

(36.5)
Hardware
Nuts &

1 19⁄32"
1 19⁄32" (40.5)
(40.5)
General
Fittings

R-As shown R-As shown


L-Opposite hand L-Opposite hand
Pipe/Conduit
Supports

A2223 Wt/100 pcs: 34 Lbs (15.4 kg) A2345 Wt/100 pcs: 41 Lbs (18.6 kg)

1 7⁄16" 1 7⁄16"
Electrical
Fittings

(36.5) (36.5)
Concrete
Inserts

1 19⁄32"
1 19⁄32" (40.5)
(40.5)
11⁄4" Framing
System
Framing
System

A2227 Wt/100 pcs: 52 Lbs (23.6 kg) A1047 Wt/100 pcs: 43 Lbs (19.5 kg)
13⁄16"

1 7⁄16"
(36.5) 4 1⁄2"
Fiberglass

(114.3)
System

3 1⁄4" 1 1⁄4"
(82.6) (31.8)
Special
Metals

1 19⁄32"
(40.5)
PrimeAngle
System

A1000
Product
Index

Standard Dimensions for 11⁄4" (32 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄32" (10.3mm); Hole Spacing - From End: 5⁄8" (15.9 mm); Hole Spacing - On Center: 11⁄2" (38.1 mm); Width: 11⁄4"(31.8mm); Thickness: 3⁄16" (4.8mm)
13

222 11⁄4" Framing System


"U" Shape Fittings and Tubing Clips

A3347 Wt/100 pcs: 37 Lbs (16.8 kg) A4047 Wt/100 pcs: 34 Lbs (15.4 kg)

Channel
15⁄8"
Telestrut
System
4 1⁄ 2" 4 1⁄2"
(114.3) (114.3)
5
3 ⁄8"
⁄4 " (15.9)
(19.1)

Hardware
Nuts &
A3300

General
Fittings
A4000

Pipe/Conduit
Supports
A5047 Wt/100 pcs: 58 Lbs (26.3 kg) A5043 Wt/100 pcs: 50 Lbs (22.7 kg)

Electrical
4 1⁄2"

Fittings
(114.3)
5 3⁄4" 1 1⁄4"
2 1⁄2" (146.1) (31.8)
(63.5)

Concrete
Inserts
11⁄4" Framing
1 1⁄4"

System
A5000 (31.8)
A5000

⁄16" Framing
System
A2608 thru A2617 1"
UNI-CLIP®
(25.4) Part Pipe Size O.D. Size Wt/100 pcs
Number In (mm) In (mm) Lbs (kg)

13
1
A2608 ⁄4 0.540 0.6
6.4 13.7 0.3

Fiberglass
System
3
A2609 ⁄8 0.675 0.7
9.5 17.1 0.3
1
A2611 ⁄2 0.840 1.0
12.7 21.3 0.5
3
A2612 ⁄4 1.050 1.4
Special
Metals

19.1 26.7 0.6


A2613 1 1.315 2.0
25.4 33.4 0.9
A2614 11⁄4 1.660 2.4
PrimeAngle

31.8 42.2 1.1


System

A2615 11⁄2 1.900 3.2


Stainless steel, Type 301. 38.1 48.3 1.5
Patent No. 2863625. A2617 2 2.375 4.7
50.8 60.3 2.1
Product
Index

Standard Dimensions for 11⁄4" (32 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄32" (10.3mm); Hole Spacing - From End: 5⁄8" (15.9 mm); Hole Spacing - On Center: 11⁄2" (38.1 mm); Width: 11⁄4"(31.8mm); Thickness: 3⁄16" (4.8mm)
13

11⁄4" Framing System 223


® Brackets

A2491 R-L, A2492 R-L, A2493 R-L


Channel
15⁄8"
Telestrut

A A
System

2" 2"
9 (50.8) (50.8) 9
⁄16"
⁄16"
(14.3) (14.3)
C C
1" 1"
Hardware

(25.4)
Nuts &

B (25.4) B
5
⁄8" 5
⁄8"
(15.9)
(15.9)
3
⁄16" (4.8) Holes 3
⁄16" (4.8) Holes
13
⁄32" (10.3) Dia.
General
Fittings

13
⁄32" (10.3) Dia.

Right Left

Material: 14 Gauge Steel.


Pipe/Conduit
Supports

Design Uniform Load Part A B C Wt/100 pcs


(Channel Upright Listed) Number In (mm) In (mm) In (mm) Lbs (kg)
A1000 200 Lbs (.9 kN) A2491 R-L 6 2 3 38
A4000 130 Lbs (.6 kN) 152.4 50.8 76.2 17.2
A2492 R-L 8 21⁄2 5 56
Electrical

Safety Factor of 21⁄2


Fittings

203.2 63.5 127.0 25.4


A2493 R-L 10 3 7 73
254.0 76.2 177.8 33.1
Concrete
Inserts

A2494 R-L thru A2497 R-L


11⁄4" Framing
System

9 2" 2"
⁄16" 9
⁄16"
(14.3) (50.8) A (50.8)
A (14.3)
C C
3" 3"
(76.2) (76.2)
Framing

C C
System

B 1" B
1" (25.4)
(25.4)
13⁄16"

5
3
⁄16" (4.8) Holes 5
⁄8" ⁄8" 3
⁄16" (4.8) Holes
Fiberglass

13 (15.9) (15.9) 13
⁄32" (10.3) Dia.
⁄32" (10.3) Dia.
System

Right Left

Material: 14 Gauge Steel.


Special
Metals

Design Uniform Load Part A B C Wt/100 pcs


(Channel Upright Listed) Number In (mm) In (mm) In (mm) Lbs (kg)
A1000 200 Lbs (.9 kN) A2494 R-L 12 31⁄2 3 94
PrimeAngle

A4000 130 Lbs (.6 kN) 304.8 88.9 76.2 42.6


System

A2495 R-L 14 4 4 105


Safety Factor of 21⁄2
355.6 101.6 101.6 47.6
A2496 R-L 16 41⁄2 5 145
406.4 114.3 127.0 65.8
A2497 R-L 18 5 6 175
Product
Index

457.2 127.0 152.4 79.4

224 11⁄4" Framing System


13
® ⁄16" FRAMING SYSTEM
P6000 (19 Gauge) ..................................... 228-230
P7000 (19 Gauge) ..................................... 231-232
Channel Nuts and Closure Strips ................... 233
Flat Plate Fittings ..................................... 234-236
Ninety Degree Fittings ............................ 237-241
Angular Fittings ............................................... 241
“Z” Shape Fittings .................................... 242-243
“U” Shape Fittings ................................... 243-245
Special Application Fittings ........................... 245
Beam Clamps .................................................... 246
Tubing Clips ...................................................... 246

MATERIAL APPLICATION
Channels are accurately and carefully cold formed to size A unique half-size reduction of the 15⁄8" channel width series,
from low-carbon strip steel. this smaller channel size can be used to carry light loads
STEEL: PLAIN economically in applications such as instrumentation, retail
19 Gauge (1.0 mm) ASTM A1008 displays and light-duty laboratory supports. It also provides
the flexibility found in all Unistrut® framing systems.
STEEL: PRE-GALVANIZED
19 Gauge (1.0 mm) ASTM A653 GR 33 DESIGN BOLT TORQUE
All nuts are manufactured from mild steel bars conforming
to ASTM A1011 SS Grade 33. Rec. Torque 6 Max Torque 7
BOLT SIZE 1⁄4" - 20 Ft/Lbs (N•m) (8) Ft/Lbs (N•m) (9)
Fittings are made from hot rolled, pickled and oiled steel
plate or strip and conform to ASTM A1011 SS GR 33.
DIMENSIONS
FINISHES Imperial dimensions are illustrated in inches. Metric
Channels are available in: Perma-Green II (GR), dimensions are shown in parenthesis or as noted. Unless
electro-galvanized (EG), Pre-galvanized (PG), conforming to noted, all metric dimensions are in millimeters and rounded
ASTM A653 GR 33 and plain (PL). to one decimal place.
Nuts are available in plain or electro-galvanized (EG) finish.
LOAD DATA
Fittings are available in Perma-Green II, electrogalvanized (EG)
All beam and column load data pertains to carbon steel
with zinc electrolytically to commercial standards ASTM and stainless steel channels. Load tables and charts are
B653-G90 Type III SC1; or plain. constructed to be in accordance with the SPECIFICA-
TION FOR THE DESIGN OF COLD-FORMED STEEL
STANDARD LENGTHS STRUCTURAL MEMBERS 2001 EDITION published by the
P-6000 – 16 Feet (4.88m) AMERICAN IRON AND STEEL INSTITUTE.
P-7000 – 10 Feet (3.05m) Type Safety Factor Safety Factor
Tolerances are +1⁄8" (3.2 mm) to +1⁄2" (12.7 mm) to allow for of Load to Yield Strength to Ultimate Strength
cutting. Special lengths are available for a small cutting Beam Loads 1.67 2.0
charge with a tolerance of ± 1⁄8" (3.2mm).
Column Load 1.80 2.2

225
13
® ⁄16" Framing System Pictorial Index

P6000 Series
Channel
15⁄8"

13⁄16"x 13⁄16"
19 Ga.
Telestrut
System

P6000 - Pg 228 P6001 - Pg 228 P6001 A - Pg 228 P6001 B - Pg 228 P6001 C - Pg 228

P7000 Series
Hardware
Nuts &

13⁄16"x 13⁄32"
19 Ga.
P7000 - Pg 231 P7001 - Pg 231
General
Fittings

Channel Nuts & Closures


Pipe/Conduit
Supports

P6000-0832 - Pg 233 P7006-0832 - Pg 233 P6280 - Pg 233 P7280 - Pg 233 P6184P - Pg 233

13⁄16"
Series Fittings
Electrical
Fittings
Concrete
Inserts

P6062 - Pg 234 P6065 - Pg 234 P6924 - Pg 234 P7325 - Pg 234 P7324 - Pg 234 P6925 - Pg 234
11⁄4" Framing
System

P6066 - Pg 235 P6067 - Pg 235 P6962 - Pg 235 P6356 A - Pg 235 P6358 A - Pg 235 P6726 A - Pg 235
⁄16" Framing
System
13
Fiberglass

P6334 - Pg 236 P6380 - Pg 236 P6036 - Pg 236 P6380 A - Pg 236 P6031 - Pg 236 P6028 - Pg 236
System
Special
Metals

P6026 - Pg 237 P6068 - Pg 237 P6281 - Pg 237 P6069 - Pg 237 P6326 - Pg 237 P6346 - Pg 237
PrimeAngle
System
Product
Index

P6458 - Pg 238 P6325 - Pg 238 P6033 - Pg 238 P6037 - Pg 238 P6038 - Pg 238 P6357 - Pg 238

13
226 ⁄16" Framing System
13
⁄16" Framing System Pictorial Index

13⁄16" Series Fittings

Channel
15⁄8"
Telestrut
System
P6359-Pg 239 P6579-Pg 239 P6728-Pg 239 P6917-Pg 239 P6918-Pg 239 P7235-Pg 239

Hardware
Nuts &
General
P6130-Pg 240 P6290-Pg 240 P6291-Pg 240 P6381-Pg 240 P6382-Pg 240 P6887-Pg 240

Fittings
Pipe/Conduit
Supports
P6331-Pg 241 P6332-Pg 241 P6546-Pg 241 P6186-Pg 241 P6045-Pg 242 P7045-Pg 242

Electrical
Fittings
Concrete
Inserts
P6347-Pg 242 P7347-Pg 242 P6453-Pg 242 P6454-Pg 242 P6758-Pg 243 P7758-Pg 243

11⁄4" Framing
System
P6047-Pg 243 P6737-Pg 243 P6048-Pg 243 P7048-Pg 243 P6376-Pg 244 P7376-Pg 244

Framing
System
13⁄16"
Fiberglass
P6376 A-Pg 244 P7376 A-Pg 244 P6377-Pg 244 P7377-Pg 244 P6044-Pg 245 P6455-Pg 245

System
Special
Metals

P6973-Pg 245 P6349-Pg 245 P6353-Pg 245 P6127-Pg 245 P6379 S-Pg 246 P6386-Pg 246
PrimeAngle
System
Product
Index

P6805-Pg 246 P7008-Pg 246

13
⁄16" Framing System 227
® P6000 & P6001 Channel

P6000 Wt/100 Ft: 36 Lbs (54 kg/100 m)


Channel

13
⁄16" 20.6 Allowable Moment 510 In-Lbs (60 N•m)
15⁄8"

7
3
⁄16" 3 11.1 19 Gauge Nominal Thickness .040" (1.0 mm)
⁄16" ⁄16" 4.8 4.8
Telestrut
System

3
.463" 11.8
13 ⁄32"
⁄16" 1 20.6 2.4 1
.350" 8.4

2 2
Hardware
Nuts &

P6001 Wt/100 Ft: 73 Lbs (108 kg/100 m)


Allowable Moment 1,390 In-Lbs (160 N•m)
13
19 Gauge Nominal Thickness .040" (1.0 mm)
⁄16" 20.6
General
Fittings

13
⁄16" 20.6
Pipe/Conduit

1 5⁄8" 1 41.3 1
Supports

13 20.6
⁄16"

2 2
Electrical
Fittings

P6001A 13
⁄16" 20.6
Wt/100 Ft: 73 Lbs (108 kg/100 m)
Allowable Moment 1,820 In-Lbs (210 N•m)
19 Gauge Nominal Thickness .040" (1.0 mm)

13 20.6
⁄16"
Concrete
Inserts

1 5⁄8" 41.3

13
⁄16" 20.6
11⁄4" Framing
System

P6001B Wt/100 Ft: 73 Lbs (108 kg/100 m)


13
Allowable Moment 1,820 In-Lbs (210 N•m)
⁄16" Framing

⁄16" 20.6 19 Gauge Nominal Thickness .040" (1.0 mm)


System

13
⁄16" 20.6
13

1 5⁄8" 41.3
Fiberglass
System

13
⁄16" 20.6
Special
Metals

P6001C 13
⁄16" 20.6
Wt/100 Ft: 73 Lbs (108 kg/100 m)
Allowable Moment 1,550 In-Lbs (180 N•m)
19 Gauge Nominal Thickness .040" (1.0 mm)
PrimeAngle

13 20.6
⁄16"
System

1 5⁄8" 41.3

13 20.6
⁄16"
Product
Index

13
228 ⁄16" Framing System
P6000 & P6001 Channels

BEAM LOADING – P6000 BEAM LOADING – P6001

Channel
15⁄8"
Max Defl. at Max Defl. at
Allowable Uniform Uniform Loading at Deflection Allowable Uniform Uniform Loading at Deflection
Span Uniform Load Load Span/180 Span/240 Span/360 Span Uniform Load Load Span/180 Span/240 Span/360

Telestrut
System
In Lbs In Lbs Lbs Lbs In Lbs In Lbs Lbs Lbs
18 230 0.06 230 230 180 18 620 0.04 620 620 620
24 170 0.11 170 150 100 24 460 0.06 460 460 460
30 140 0.18 130 100 70 30 370 0.10 370 370 320

Hardware
Nuts &
36 110 0.24 90 70 50 36 310 0.14 310 310 220
42 100 0.35 70 50 30 42 270 0.20 270 240 160
48 80 0.42 50 40 30 48 230 0.25 230 180 120
54 80 0.60 40 30 20 54 210 0.32 190 150 100

General
Fittings
60 70 0.72 30 20 20 60 190 0.40 160 120 80
66 60 0.82 30 20 10 66 170 0.48 130 100 70
72 60 1.06 20 20 10 72 150 0.55 110 80 50

Pipe/Conduit
Supports
COLUMN LOADING – P6000 COLUMN LOADING – P6001
Maximum Maximum
Unbraced Allowable Load Maximum Column Load Applied at C.G. Unbraced Allowable Load Maximum Column Load Applied at C.G.

Electrical
Fittings
Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
In Lbs Lbs Lbs Lbs Lbs In Lbs Lbs Lbs Lbs Lbs
18 600 1,660 1,400 1,100 860 18 1,210 4,320 4,080 3,770 3,500
24 490 1,300 1,010 740 590 24 1,170 3,980 3,680 3,330 3,060

Concrete
Inserts
30 420 990 740 560 450 30 1,130 3,650 3,330 3,000 2,460
36 340 770 590 450 370 36 1,070 3,370 3,060 2,460 1,800
42 300 630 490 380 310 42 1,020 3,140 2,690 1,900 1,320

11⁄4" Framing
48 260 540 420 330 270 48 900 2,930 2,230 1,460 1,010

System
54 240 470 370 290 ** 54 820 2,550 1,800 1,150 800
60 210 410 330 ** ** 60 700 2,180 1,460 930 **
66 210 370 300 ** ** 66 700 1,830 1,210 770 **
72 180 340 270 ** ** 72 550 1,530 1,010 ** **

Framing
System
ELEMENTS OF SECTION

13⁄16"
P6000 & P6001
Notes:

Fiberglass
Parameter P6000 P6001

System
* Load limited by spot weld shear.
Area of Section 0.107 In2 0.213 In2
** KL⁄r > 200
Axis 1-1
Moment of Inertia (I) 0.009 In4 0.045 In4 NR = Not Recommended.
Section Modulus (S) 0.020 In3 0.055 In3 1. Above loads include the weight of the member. This weight must be
Special
Metals

Radius of Gyration (r) 0.295 In 0.460 In deducted to arrive at the net allowable load the beam will support.
Axis 2-2 2. Long span beams should be supported in such a manner as to
prevent rotation and twist.
Moment of Inertia (I) 0.012 In4 0.024 In4
3. Allowable uniformly distributed loads are listed for various simple
PrimeAngle

Section Modulus (S) 0.029 In3 0.058 In3 spans, that is, a beam on two supports. If load is concentrated at
System

Radius of Gyration (r) 0.333 In 0.333 In the center of the span, multiply load from the table by 0.5 and
corresponding deflection by 0.8.
Product
Index

13
⁄16" Framing System 229
® P6000 & P6001 Channel
Channel

BEAM LOADING – P6000 (METRIC) BEAM LOADING – P6001 (METRIC)


15⁄8"

Max Defl. at Maximum


Allowable Uniform Uniform Loading at Deflection Unbraced Allowable Load Maximum Column Load Applied at C.G.
Telestrut
System

Span Uniform Load Load Span/180 Span/240 Span/360 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
mm kg mm kg kg kg mm kg kg kg kg kg
300 154 1 154 154 154 300 295 * 0 295 * 295 * 295 *
450 104 2 104 104 86 450 286 1 286 286 286
Hardware
Nuts &

600 77 3 77 73 50 600 213 2 213 213 213


750 64 4 59 45 32 750 172 2 172 172 150
1,000 45 7 36 27 18 1,000 127 4 127 122 82
1,250 36 11 23 18 9 1,250 104 7 104 82 54
General
Fittings

1,500 32 17 14 14 9 1,500 86 10 73 54 36
1,750 27 24 9 9 5 1,750 73 13 54 41 27
2,000 64 17 41 32 23
Pipe/Conduit
Supports

COLUMN LOADING – P6000 (METRIC) COLUMN LOADING – P6001 (METRIC)


Max Defl. at Maximum
Electrical
Fittings

Allowable Uniform Uniform Loading at Deflection Unbraced Allowable Load Maximum Column Load Applied at C.G.
Span Uniform Load Load Span/180 Span/240 Span/360 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
mm kg mm kg kg kg mm kg kg kg kg kg
300 318 934 857 748 644 300 562 2,114 2,050 1,955 1,860
Concrete
Inserts

450 277 762 644 508 399 450 549 1,969 1,860 1,724 1,597
600 227 599 467 345 272 600 531 1,814 1,678 1,524 1,402
750 186 458 345 259 209 750 513 1,669 1,524 1,374 1,143
1,000 141 308 240 186 154 1,000 467 1,470 1,315 971 685
11⁄4" Framing

1,250 113 236 186 145 118 1,250 399 1,293 971 630 435
System

1,500 95 191 154 118 ** 1,500 327 1,012 685 435 **


1,750 82 163 127 ** ** 1,750 268 762 503 ** **
2,000 222 581 386 ** **
⁄16" Framing
System
13
Fiberglass
System

METRIC ELEMENTS OF SECTION


P6000 & P6001 (METRIC)
Notes:
Special

Parameter P6000 P6001


Metals

Area of Section 0.69 cm 2


1.38 cm 2 * Load limited by spot weld shear.
Axis 1-1 ** KL⁄r > 200
4 4
Moment of Inertia (I) 0.39 cm 1.88 cm NR = Not Recommended.
PrimeAngle

Section Modulus (S) 0.33 cm3 0.91 cm3


System

1. Above loads include the weight of the member. This weight must be
Radius of Gyration (r) 0.75 cm 1.17 cm deducted to arrive at the net allowable load the beam will support.
Axis 2-2 2. Long span beams should be supported in such a manner as to
Moment of Inertia (I) 0.49 cm4 0.99 cm4 prevent rotation and twist.
Section Modulus (S) 0.48 cm3 0.96 cm3 3. Allowable uniformly distributed loads are listed for various simple
Product

spans, that is, a beam on two supports. If load is concentrated at


Index

Radius of Gyration (r) 0.85 cm 0.85 cm the center of the span, multiply load from the table by 0.5 and
corresponding deflection by 0.8.

13
230 ⁄16" Framing System
P7000 & P7001 Channels

P7000 Wt/100 Ft: 25 Lbs (38 kg/100m)

Channel
Allowable Moment 170 In-Lbs (20 N•m)

15⁄8"
13
⁄16" 20.6 19 Gauge Nominal Thickness .040" (1.0 mm)
7
⁄16" 11.1
3
⁄16" 3
⁄16" 4.8 4.8
3 2.4 6.2
⁄32" .243"

Telestrut
System
13
⁄32" 1 10.3 1

2 2 4.1
.163"

Hardware
Nuts &
P7001 Wt/100 Ft: 50 Lbs (75 kg/100m)
Allowable Moment 450 In-Lbs (50 N•m)
13 20.6 19 Gauge Nominal Thickness .040" (1.0 mm)
⁄16"

General
Fittings
13 10.3
⁄32"
13 20.6 1
⁄16" 1
13 10.3
⁄32"

Pipe/Conduit
2

Supports
2

BEAM LOADING – P7000 BEAM LOADING – P7001


Max Defl. at Maximum

Electrical
Fittings
Allowable Uniform Uniform Loading at Deflection Unbraced Allowable Load Maximum Column Load Applied at C.G.
Span Uniform Load Load Span/180 Span/240 Span/360 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
In Lbs In Lbs Lbs Lbs In Lbs Lbs Lbs Lbs Lbs
18 80 0.12 60 50 30 18 200 0.07 200 200 140

Concrete
Inserts
24 60 0.22 40 30 20 24 150 0.12 150 120 80
30 50 0.36 20 20 10 30 120 0.19 100 80 50
36 40 0.50 20 10 10 36 100 0.28 70 50 40
42 90 0.40 50 40 30

11⁄4" Framing
48 80 0.53 40 30 20

System
COLUMN LOADING – P7000 COLUMN LOADING – P7001
Max Defl. at Maximum
Allowable Uniform Uniform Loading at Deflection Unbraced Allowable Load Maximum Column Load Applied at C.G.

Framing
Span Uniform Load Load Span/180 Span/240 Span/360 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2

System
In Lbs In Lbs Lbs Lbs In Lbs Lbs Lbs Lbs Lbs

13⁄16"
18 420 1,200 990 720 510 18 790 2,930 2,690 2,330 1,960
24 330 900 640 410 280 24 740 2,570 2,210 1,720 1,260
30 260 620 410 ** ** 30 680 2,180 1,720 1,160 800

Fiberglass
System
36 200 430 280 ** ** 36 580 1,780 1,260 800 560
42 500 1,400 920 590 **
ELEMENTS OF SECTION 48 420 1,070 710 ** **
54 360 850 560 ** **
P7000 & P7001
Special
Metals

Parameter P7000 P7001 Notes:


2
Area of Section 0.074 In 0.148 In2 1. Above loads include the weight of the member. This weight must be
Axis 1-1 deducted to arrive at the net allowable load the beam will support.
PrimeAngle

Moment of Inertia (I) 0.002 In4 0.007 In4 2. Long span beams should be supported in such a manner as to
System

prevent rotation and twist.


Section Modulus (S) 0.007 In3 0.018 In3
3. Allowable uniformly distributed loads are listed for various simple
Radius of Gyration (r) 0.150 In 0.222 In spans, that is, a beam on two supports. If load is concentrated at
Axis 2-2 the center of the span, multiply load from the table by 0.5 and
Moment of Inertia (I) 0.007 In4 0.014 In4 corresponding deflection by 0.8.
Product
Index

Section Modulus (S) 0.017 In3 0.034 In3


Radius of Gyration (r) 0.307 In 0.307 In

13
⁄16" Framing System 231
® P7000 & P7001 Channel

BEAM LOADING – P7000 (METRIC) BEAM LOADING – P7001 (METRIC)


Channel
15⁄8"

Max Defl. at Maximum


Allowable Uniform Uniform Loading at Deflection Unbraced Allowable Load Maximum Column Load Applied at C.G.
Span Uniform Load Load Span/180 Span/240 Span/360 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
Telestrut
System

mm kg mm kg kg kg mm kg kg kg kg kg
300 54 1 54 50 36 300 141 1 141 141 141
450 36 3 32 23 14 450 95 2 95 95 68
600 27 5 18 14 9 600 68 3 68 54 36
Hardware
Nuts &

750 23 9 9 9 5 750 54 5 50 36 23
1,000 18 16 5 5 5 1,000 41 8 27 18 14
1,250 14 24 5 5 NR 1,250 32 13 18 14 9
1,500 9 28 5 NR NR 1,500 27 19 14 9 5
General
Fittings

COLUMN LOADING – P7000 (METRIC) COLUMN LOADING – P7001 (METRIC)


Max Defl. at Maximum
Pipe/Conduit

Allowable Uniform Uniform Loading at Deflection Unbraced Allowable Load Maximum Column Load Applied at C.G.
Supports

Span Uniform Load Load Span/180 Span/240 Span/360 Height at Slot Face K = 0.65 K = 0.80 K =1.0 K = 1.2
mm kg mm kg kg kg mm kg kg kg kg kg
300 213 653 608 540 458 300 372 1,429 1,383 1,324 1,229
450 191 549 458 336 236 450 358 1,334 1,229 1,070 907
Electrical
Fittings

600 154 417 299 191 132 600 340 1,179 1,016 794 590
750 118 290 191 122 ** 750 308 1,002 794 544 376
1,000 240 708 476 304 **
ELEMENTS OF SECTION 1,250 181 463 304 ** **
Concrete
Inserts

P7000 & P7001 (METRIC)


Parameter P7000 P7001 Notes:
1. Above loads include the weight of the member. This weight must be
Area of Section 0.48 cm2 0.96 cm2
deducted to arrive at the net allowable load the beam will support.
Axis 1-1
11⁄4" Framing

2. Long span beams should be supported in such a manner as to


0.07 cm4 0.31 cm4
System

Moment of Inertia (I) prevent rotation and twist.


Section Modulus (S) 0.11 cm3 0.30 cm3 3. Allowable uniformly distributed loads are listed for various simple
Radius of Gyration (r) 0.38 cm 0.57 cm spans, that is, a beam on two supports. If load is concentrated at
Axis 2-2 the center of the span, multiply load from the table by 0.5 and
corresponding deflection by 0.8.
Moment of Inertia (I) 0.29 cm4 0.58 cm4
⁄16" Framing

Section Modulus (S) 0.28 cm3 0.56 cm3


System

Radius of Gyration (r) 0.78 cm 0.78 cm


13

LOAD DATA FOR UNISTRUT SECTIONS SUBJECT TO CRUSHING LOADS


LOAD LOAD
Fiberglass
System

Allowable Load Allowable Load


at Center of Member at End of member
Channel Lbs (kg) Channel Lbs (kg)
P6000 1,000 P6000 700
Special
Metals

453 318
P7000 1,300 P7000 900
590 408
PrimeAngle
System

Maximum Allowable Pull-Out And Slip Loads


Max. AllowableResistance
Nut Size/ Pull-Out to Slip Torque
Thread Lbs (kg) Lbs (kg) Ft-Lbs (N•m)
Product
Index

1
⁄4"-20 250 150 6
113 68 8

13
232 ⁄16" Framing System
Channel Nuts, Caps & Closures

P6006-0832 thru P6006-1420 P7006-0832 thru P7006-1420

Channel
15⁄8"
Channel Nut With Spring Channel Nut With Spring

Telestrut
Part Thread Size Wt/100 pcs Part Thread Size Wt/100 pcs

System
Number In Lbs (kg) Number In Lbs (kg)
P6006-0836 #8 - 36 1 P7006-0836 #8 - 36 1
0.5 0.5
P6006-0832 #8 - 32 1 P7006-0832 #8 - 32 1

Hardware
Nuts &
0.5 0.5
P6006-1032 #10 - 32 1 P7006-1032 #10 - 32 1
0.5 0.5
P6006-1024 #10 - 24 1 P7006-1024 #10 - 24 1
0.5 0.5

General
Fittings
1 1
P6006-1420 ⁄4"- 20 1 P7006-1420 ⁄4"- 20 1
0.5 0.5

Pipe/Conduit
Supports
P6280 End Cap for P6000 P7280 End Cap for P7000
Wt/100 pcs: 3 Lbs (1.4 kg) Wt/100 pcs: 1 Lbs (0.5 kg)

Electrical
Fittings
Concrete
Inserts
11⁄4" Framing
System
Material: .060" (1.5) Material: .048" (1.2)

Framing
System
P6184 P Closure Strip
Wt/100 Ft: 4 Lbs (6.0 kg/100m)

13⁄16"
Fiberglass
System
1
⁄16"
(1.6)
Special
Metals

.706"
(17.9)
PrimeAngle
System
Product
Index

Material: PVC, Plastic.


Standard Length: 10 Feet (3.05 m).

13
⁄16" Framing System 233
® Flat Plate Fittings

P6062 Wt/100 pcs: 2 Lbs (0.9 kg) P6065 Wt/100 pcs: 5 Lbs (2.3 kg)
Channel
15⁄8"
Telestrut
System

1 7⁄8"
13⁄16" (47.6)
(20.6)
Hardware
Nuts &
General
Fittings
Pipe/Conduit
Supports

P6924 Wt/100 pcs: 5 Lbs (2.3 kg) P7325 Wt/100 pcs: 7 Lbs (3.2 kg)
Electrical
Fittings

1 5⁄8"
(41.3)

13⁄16"
2 11⁄16"
(68.3)
Concrete
Inserts

(20.6)

1 7⁄8"
(47.6)
11⁄4" Framing
System
⁄16" Framing
System

P7324 Wt/100 pcs: 10 Lbs (4.5 kg) P6925 Wt/100 pcs: 7 Lbs (3.2 kg)
13

2 7⁄16"
Fiberglass
System

(61.9)

3 3⁄4"
(95.3)
Special
Metals

1 7⁄8"
(47.6)
13⁄16"
(20.6)
13⁄16"
PrimeAngle

(20.6)
System
Product
Index

Standard Dimensions for 13⁄16" (21 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄32" (7.1mm); Hole Spacing - From End: 13⁄32" (10.3mm); Hole Spacing - On Center: 11⁄16" (27.0 mm); Width: 13⁄16"(20.6mm); Thickness: 1⁄8" (3.2mm)
9

13
234 ⁄16" Framing System
Flat Plate Fittings

P6066 Wt/100 pcs: 8 Lbs (3.6 kg) P6067 Wt/100 pcs: 11 Lbs (5.0 kg)

Channel
15⁄8"
2 15⁄16"

Telestrut
System
(74.6)
4"
(101.6)

Hardware
Nuts &
General
Fittings
Pipe/Conduit
Supports
P6962 Wt/100 pcs: 19 Lbs (8.6 kg) P6356A Wt/100 pcs: 10 Lbs (4.5 kg)

Electrical
Fittings
1 7⁄ 8 "
(47.6)

Concrete
Inserts
2 5⁄16"
(58.7)
1 7⁄8"

11⁄4" Framing
2 5⁄16" (47.6)

System
(58.7)

Framing
System
P6358A Wt/100 pcs: 15 Lbs (6.8 kg) P6726A Wt/100 pcs: 22 Lbs (10.0 kg)

13⁄16"
Fiberglass
System
2 15⁄16" 2 15⁄16"
(74.6) (74.6)
Special
Metals

2 15⁄16"
1 7⁄8"
PrimeAngle

(74.6)
System

(47.6)
Product
Index

Standard Dimensions for 13⁄16" (21 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄32" (7.1mm); Hole Spacing - From End: 13⁄32" (10.3mm); Hole Spacing - On Center: 11⁄16" (27.0 mm); Width: 13⁄16"(20.6mm); Thickness: 1⁄8" (3.2mm)
9

13
⁄16" Framing System 235
® Flat Plate Fittings

P6334 Wt/100 pcs: 11 Lbs (5.0 kg) P6380 Wt/100 pcs: 15 Lbs (6.8 kg)
Channel
15⁄8"

1 7⁄8"
Telestrut
System

(47.6) 2 15⁄16"
(74.6)

1 7⁄8"
1 7⁄8"
Hardware

(47.6)
Nuts &

(47.6)
General
Fittings
Pipe/Conduit
Supports

P6036 Wt/100 pcs: 8 Lbs (3.6 kg) P6380A Wt/100 pcs: 11 Lbs (5.0 kg)
Electrical
Fittings

1 7⁄8"
(47.6) 2 15⁄16"
(74.6)
Concrete
Inserts

1 7⁄8" 1 7⁄8"
(47.6) (47.6)
11⁄4" Framing
System
⁄16" Framing
System

P6031 Wt/100 pcs: 11 Lbs (5.0 kg) P6028 Wt/100 pcs: 14 Lbs (6.4 kg)
13

2 15⁄16"
Fiberglass

(74.6) 2 15⁄16"
System

(74.6)
1 7⁄8"
(47.6)
Special
Metals

2 15⁄16"
PrimeAngle

(74.6)
System
Product
Index

Standard Dimensions for 13⁄16" (21 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄32" (7.1mm); Hole Spacing - From End: 13⁄32" (10.3mm); Hole Spacing - On Center: 11⁄16" (27.0 mm); Width: 13⁄16"(20.6mm); Thickness: 1⁄8" (3.2mm)
9

13
236 ⁄16" Framing System
Ninety Degree Fittings

P6026 Wt/100 pcs: 5 Lbs (2.3 kg) P6068 Wt/100 pcs: 5 Lbs (2.3 kg)

Channel
15⁄8"
Telestrut
System
1 1⁄8" 13
⁄16"
(28.6) (20.6)
15
⁄16" 1 1⁄4"

Hardware
(23.8)

Nuts &
(31.8)

General
Fittings
Pipe/Conduit
Supports
P6281 , P6282, P6283 P6069 Wt/100 pcs: 8 Lbs (3.6 kg)

1 1⁄8"

Electrical
Fittings
A (28.6)
15
⁄16"
(23.8)
2"
(50.8)

Concrete
Inserts
Part A Wt/100 pcs
Number In (mm) Lbs (kg)
P6281 2 8

11⁄4" Framing
50.8 3.6

System
P6282 21⁄2 9
63.5 4.1
P6283 3 10
76.2 4.5

Framing
System
P6326 Wt/100 pcs: 8 Lbs (3.6 kg) P6346 Wt/100 pcs: 8 Lbs (3.6 kg)

13⁄16"
Fiberglass
27
⁄32" 15
⁄16"

System
(21.4) (23.8)

2 5⁄16"
(58.7) 2 3⁄16"
(55.6)
Special
Metals
PrimeAngle
System
Product
Index

Standard Dimensions for 13⁄16" (21 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄32" (7.1mm); Hole Spacing - From End: 13⁄32" (10.3mm); Hole Spacing - On Center: 11⁄16" (27.0 mm); Width: 13⁄16"(20.6mm); Thickness: 1⁄8" (3.2mm)
9

13
⁄16" Framing System 237
® Ninety Degree Fittings

P6458 Wt/100 pcs: 8 Lbs (3.6 kg) P6325 Wt/100 pcs: 11 Lbs (5.0 kg)
Channel
15⁄8"
Telestrut

1 7⁄8"
System

7 (47.6)
1 ⁄8"
(47.6)

1 1⁄4" 2 5⁄16"
Hardware
Nuts &

(31.8) (58.7) 27
⁄32"
(21.4)
General
Fittings
Pipe/Conduit
Supports

P6033 Wt/100 pcs: 11 Lbs (5.0 kg) P6037 Wt/100 pcs: 8 Lbs (3.6 kg)
Electrical
Fittings

1 1⁄8"
(28.6)
Concrete
Inserts

2 15⁄16"
(74.6) 1 1 ⁄8 "
11⁄4" Framing

(28.6)
1 15⁄16"
System

(49.2)
⁄16" Framing
System

P6038 Wt/100 pcs: 8 Lbs (3.6 kg) P6357 Wt/100 pcs: 10 Lbs (4.5 kg)
13
Fiberglass
System

1 7⁄8"
(47.6)

1 1⁄4"
Special
Metals

(31.8)
PrimeAngle

1 1⁄8" 1 15⁄16"
System

(49.2)
(28.6)
Product
Index

Standard Dimensions for 13⁄16" (21 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄32" (7.1mm); Hole Spacing - From End: 13⁄32" (10.3mm); Hole Spacing - On Center: 11⁄16" (27.0 mm); Width: 13⁄16"(20.6mm); Thickness: 1⁄8" (3.2mm)
9

13
238 ⁄16" Framing System
Ninety Degree Fittings

P6359 Wt/100 pcs: 15 Lbs (6.8 kg) P6579 Wt/100 pcs: 15 Lbs (6.8 kg)

Channel
15⁄8"
Telestrut
System
1 7⁄8" 1 7⁄8"
(47.6) (47.6) 1 7⁄8"
(47.6)
1 1⁄4"
(31.8)

Hardware
2 5⁄16"

Nuts &
(58.7)

General
Fittings
Pipe/Conduit
Supports
P6728 Wt/100 pcs: 22 Lbs (10.0 kg) P6917 Wt/100 pcs: 21 Lbs (9.5 kg)

Electrical
Fittings
13
⁄16" 1 7⁄8"
(20.6) (47.6)
2 15⁄16"
(74.6)
2 5⁄16"

Concrete
Inserts
(58.7) 27
⁄32"
(21.4)
1 7⁄8"
27 (47.6)
⁄32"
(21.4) 2 5⁄16"

11⁄4" Framing
(58.7)

System
Framing
System
P6918 Wt/100 pcs: 21 Lbs (9.5 kg) P7235 Wt/100 pcs: 18 Lbs (8.2 kg)

13⁄16"
Fiberglass
1 7⁄ 8 " 1 7⁄8"

System
(47.6) 1 7 ⁄8 "
(47.6) (47.6)

2 5⁄16"
Special

(58.7)
Metals

1 7 ⁄ 8"
(47.6) 27
⁄32"
2 5⁄16" (21.4)
PrimeAngle

(58.7)
System
Product
Index

Standard Dimensions for 13⁄16" (21 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄32" (7.1mm); Hole Spacing - From End: 13⁄32" (10.3mm); Hole Spacing - On Center: 11⁄16" (27.0 mm); Width: 13⁄16"(20.6mm); Thickness: 1⁄8" (3.2mm)
9

13
⁄16" Framing System 239
® Ninety Degree Fittings

P6130 Wt/100 pcs: 32 Lbs (14.5 kg) P6290 Wt/100 pcs: 15 Lbs (6.8 kg)
Channel
15⁄8"

15
⁄16"
Telestrut
System

(23.8)
2 3⁄16"
(55.6)
Hardware

3
Nuts &

⁄4"
2 3⁄16" (19.1)
(55.6) 1 7⁄8"
7
2 ⁄16" (47.6)
15 3
⁄4" (61.9) 4"
⁄16" (101.6)
(19.1)
General
Fittings

(23.8)
Pipe/Conduit
Supports

P6291 Wt/100 pcs: 15 Lbs (6.8 kg) P6381 Wt/100 pcs: 15 Lbs (6.8 kg)

2 5⁄16"
Electrical
Fittings

15 (58.7)
⁄16" 13
(23.8) ⁄16"
(20.6)
27
⁄32"
2 3⁄16" (21.4)
(55.6)
Concrete
Inserts

1 7 ⁄8 "
(47.6) 1 7⁄8"
11⁄4" Framing

(47.6)
System
⁄16" Framing
System

P6382 Wt/100 pcs: 15 Lbs (6.8 kg) P6887 Wt/100 pcs: 28 Lbs (12.7 kg)
13

2 5⁄16"
(58.7) 15
⁄16"
Fiberglass

31
1 ⁄32" 1 31
⁄32"
System

13 (23.8)
27 ⁄16" (50.0) (50.0)
⁄32" (20.6)
(21.4)

2"
Special
Metals

(50.8)

1 7 ⁄8 "
(47.6)
PrimeAngle
System
Product
Index

Standard Dimensions for 13⁄16" (21 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄32" (7.1mm); Hole Spacing - From End: 13⁄32" (10.3mm); Hole Spacing - On Center: 11⁄16" (27.0 mm); Width: 13⁄16"(20.6mm); Thickness: 1⁄8" (3.2mm)
9

13
240 ⁄16" Framing System
Ninety Degree and Angular Fittings

P6331 Wt/100 pcs: 19 Lbs (8.6 kg) P6332 Wt/100 pcs: 19 Lbs (8.6 kg)

Channel
15⁄8"
Telestrut
1 7⁄8"

System
(47.6) 1 7 ⁄8 "
(47.6)

2 5⁄16" 2 5⁄16"

Hardware
(58.7)

Nuts &
27
⁄32" 27
⁄32" (58.7)
(21.4) (21.4)

General
Fittings
Pipe/Conduit
Supports
P6546, P7097, P7098, P7100, P7101 Wt/100 pcs: 8 Lbs (3.6 kg)

Electrical
Fittings
Part A “B” “C”
Number In (mm) In (mm) Deg (rad)
15
C P7097 ⁄16 113⁄16 60°
23.8 46.0 1.1

Concrete
Inserts
P7098 11⁄32 17⁄8 521⁄2°
26.2 47.6 9.1
P6546 13⁄16 123⁄32 45°
B 30.2 43.7 0.8
P7100 15⁄16 119⁄32 371⁄2°

11⁄4" Framing
A 33.3 40.5 6.5

System
P7101 11⁄32 17⁄8 30°
26.2 47.6 0.5

Framing
System
P6186, P7108, P7109, P7110 Wt/100 pcs: 8 Lbs (3.6 kg)

13⁄16"
Part A “C”
Number In (mm) Deg (rad)

Fiberglass
P7108 127⁄32 60°

System
46.8 1.1
P7109 113⁄16 521⁄2°
C 46 9.1
P6186 113⁄16 45°
A 46.0 0.8
Special
Metals

P7110 113⁄16 371⁄2°


46 6.5
1 1⁄4"
(31.8)
PrimeAngle
System
Product
Index

Standard Dimensions for 13⁄16" (21 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄32" (7.1mm); Hole Spacing - From End: 13⁄32" (10.3mm); Hole Spacing - On Center: 11⁄16" (27.0 mm); Width: 13⁄16"(20.6mm); Thickness: 1⁄8" (3.2mm)
9

13
⁄16" Framing System 241
® “Z” Shape Fittings

P6045 Wt/100 pcs: 7 Lbs (3.2 kg) P7045 Wt/100 pcs: 6 Lbs (2.7 kg)
Channel
15⁄8"
Telestrut

1 7⁄8"
System

P6000 (47.6)
Hardware
Nuts &

13 P7000
⁄16"
(20.6) 13
⁄32"
1 1⁄16" (10.3)
13
(27.0) ⁄32"
General
Fittings

(10.3)
Pipe/Conduit
Supports

P6347 Wt/100 pcs: 7 Lbs (3.2 kg) P7347 Wt/100 pcs: 6 Lbs (2.7 kg)
Electrical
Fittings

P7000
Concrete
Inserts

P6000

15
13 ⁄16"
⁄16" (23.8)
(20.6)
11⁄4" Framing

17
15
⁄16" ⁄32"
System

(23.8) (13.5)
⁄16" Framing
System

P6453 Wt/100 pcs: 9 Lbs (4.1 kg) P6454 Wt/100 pcs: 5 Lbs (2.3 kg)
13
Fiberglass
System

P6001

1
⁄8"
Special
Metals

(3.2)

1 5⁄8"
(41.3)
PrimeAngle
System

15
⁄16"
(23.8) 1 27⁄32"
(46.8)
Product
Index

Standard Dimensions for 13⁄16" (21 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄32" (7.1mm); Hole Spacing - From End: 13⁄32" (10.3mm); Hole Spacing - On Center: 11⁄16" (27.0 mm); Width: 13⁄16"(20.6mm); Thickness: 1⁄8" (3.2mm)
9

13
242 ⁄16" Framing System
“Z” and “U” Shape Fittings

P6758 Wt/100 pcs: 13 Lbs (5.9 kg) P7758 Wt/100 pcs: 12 Lbs (5.4 kg)

Channel
15⁄8"
13 1 7⁄8" 1 7 ⁄8 "
⁄16"

Telestrut
(47.6)

System
(20.6) (47.6)
13
⁄16"
(20.6)

13
⁄16"

Hardware
P7000

Nuts &
13
(20.6) ⁄32"
(10.3)
1
1 ⁄16"
(27.0) P6000 1 1⁄16"
(27.0)

General
Fittings
Pipe/Conduit
Supports
P6047, P7047 P6737 Wt/100 pcs: 16 Lbs (7.3 kg)

2 15⁄16"
(74.6) 2 23⁄32"

Electrical
Fittings
27
(69.1)
⁄32" 27
(21.4) A ⁄32"
(21.4)

1 5⁄8"

Concrete
Inserts
(41.3)
P7000

Part A Wt/100 pcs Use with

11⁄4" Framing
Number In (mm) Lbs (kg) Channel

System
13
P6047 ⁄16 12 P6000
20.6 5.4 P6001
13
P7047 ⁄32 10 P7000
10.3 4.5

Framing
System
P6048 Wt/100 pcs: 14 Lbs (6.4 kg) P7048 Wt/100 pcs: 10 Lbs (4.5 kg)

13⁄16"
3 5⁄8"

Fiberglass
System
3
3 ⁄ 4" (92.1)
(95.3) 3
⁄4"
(19.1)
P6000
P7000
Special
Metals

2 3⁄16" 3
⁄4 "
(55.6) (19.1) 2 1⁄16"
(52.4)
PrimeAngle
System
Product
Index

Standard Dimensions for 13⁄16" (21 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄32" (7.1mm); Hole Spacing - From End: 13⁄32" (10.3mm); Hole Spacing - On Center: 11⁄16" (27.0 mm); Width: 13⁄16"(20.6mm); Thickness: 1⁄8" (3.2mm)
9

13
⁄16" Framing System 243
® “U” Shape Fittings

P6376 Wt/100 pcs: 17 Lbs (7.7 kg) P7376 Wt/100 pcs: 11 Lbs (5.0 kg)
Channel
15⁄8"

13
⁄16"
Telestrut
System

(20.6) 13
⁄32"
(10.3)
Hardware

1 7 ⁄8 " 1 7⁄8"
Nuts &

(47.6) (47.6)
General
Fittings

P7000
P6000
Pipe/Conduit
Supports

P6376A Wt/100 pcs: 26 Lbs (11.8 kg) P7376A Wt/100 pcs: 16 Lbs (7.3 kg)

13
⁄16"
Electrical

13
Fittings

(20.6) ⁄32"
(10.3)
Concrete
Inserts

15
15 2 ⁄16"
2 ⁄16" (74.6)
(74.6)
11⁄4" Framing
System

P7000
P6000
⁄16" Framing
System

P6377 Wt/100 pcs: 36 Lbs (16.3 kg) P7377 Wt/100 pcs: 24 Lbs (10.9 kg)

13
⁄16"
13

13
(20.6) ⁄32"
(10.3)
Fiberglass
System

4"
Special
Metals

4" (101.6)
(101.6)
PrimeAngle
System

P7000
P6000
Product
Index

Standard Dimensions for 13⁄16" (21 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄32" (7.1mm); Hole Spacing - From End: 13⁄32" (10.3mm); Hole Spacing - On Center: 11⁄16" (27.0 mm); Width: 13⁄16"(20.6mm); Thickness: 1⁄8" (3.2mm)
9

13
244 ⁄16" Framing System
“U” Shape Fittings and Special Applications

P6044 Wt/100 pcs: 9 Lbs (4.1 kg) P6455 Wt/100 pcs: 8 Lbs (3.6 kg)

Channel
15⁄8"
Telestrut
System
1
⁄8"
1 ⁄8"7 (3.2)
(47.6)

Hardware
Nuts &
13
⁄16"
(20.6)
P6001

General
Fittings
2 7⁄8"
(73.0)

Pipe/Conduit
Supports
P6973 Wt/100 pcs: 8 Lbs (3.6 kg) P6349 Acetal Slide
Wt/100 pcs: 1 Lbs (0.5 kg)

Electrical
Fittings
13
⁄32"
(10.3)

Concrete
1 1⁄4"

Inserts
3
(31.8) ⁄16" (4.8) Dia.
13
⁄32"
(21.4) 5⁄16"
13 13
⁄16" ⁄16" (7.9)

11⁄4" Framing
(20.6) (20.6)

System
Framing
System
P6353 Acetal Slide P6127 - P6129 Bracket
Wt/100 pcs: 1 Lbs (0.5 kg)

13⁄16"
A
C
C

Fiberglass
1 1⁄8"

System
11⁄16" B
1⁄4" (28.6)
1 (17.5)
(31.8) P6000 Special
Metals

Part Uniform Design Load “A” “B” “C” Wt/100 pcs


3⁄16" (4.8) Dia. Number Lbs (kg) In (mm) In (mm) In (mm) Lbs (kg)
27 P6127 150 61⁄2 21⁄2 21⁄2 30
⁄32" 68 165.1 63.5 63.5 13.6
(21.4)
PrimeAngle

P6128 150 81⁄2 31⁄4 31⁄2 40


System

68 215.9 82.6 88.9 18.1


P6129 130.0 101⁄2 4 41⁄2 50
59 266.7 101.6 114.3 22.7
Safety Factor 21⁄2
Product
Index

Standard Dimensions for 13⁄16" (21 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄32" (7.1mm); Hole Spacing - From End: 13⁄32" (10.3mm); Hole Spacing - On Center: 11⁄16" (27.0 mm); Width: 13⁄16"(20.6mm); Thickness: 1⁄8" (3.2mm)
9

13
⁄16" Framing System 245
® Beam Clamps and Tubing Clips

P6379 S Wt/100 pcs: 13 Lbs (5.9 kg) P6386 Wt/100 pcs: 4 Lbs (1.8 kg)
Channel
15⁄8"
Telestrut

5⁄16"(7.9) - 18 X 11⁄2"
System

Set Screw Included


Requires 1⁄4" x 3⁄4" (19.1)
1⁄4" 9
13
Machine Screw and ⁄32" (7.1) Dia.
⁄16" Channel Nut (6.4)
Hardware

(20.6) Not Included


Nuts &

Requires 1⁄4" x 3⁄4" (19.1)


Machine Screw and
Channel Nut
Not Included
General
Fittings

7⁄8"
1
⁄4" (22.2)
(6.4)
(3.2)
1 7⁄8"
(47.6)
Pipe/Conduit
Supports

Use in pairs. Use in pairs.

P6805 thru P6810 P7008 thru P7020 Tubing Clips


Electrical
Fittings

Tubing Size A
Concrete
Inserts

9
⁄32" (7.1) Dia. Hole
Material: 16 Gauge (1.5)
11⁄4" Framing
System

P7000
9
⁄32"
(7.1) Dia. Size A Size B
C
⁄16" Framing
System

13⁄32"
13
⁄16" O.D. Tube
(20.6) (10.3)
Part Size “A” Wt/100 pcs
Number In (mm) Lbs (kg)
13

1
P7008 ⁄4 1
O.D. Tube O.D. Tube 6.4 0.45
Fiberglass

Part Size “A” Size “B” “C” Wt/100 pcs


System

5
P7009 ⁄16 1
Number In (mm) In (mm) In (mm) Lbs (kg) 7.9 0.45
1 1 3
P6805 ⁄4 ⁄4 ⁄4 1 P7010 3
⁄8 2
6.4 6.4 19.1 0.5 9.5 0.91
3 3
P6806 ⁄8 ⁄8 1 2 P7012 1
⁄2 2
Special
Metals

9.5 9.5 25.4 0.9 12.7 0.91


1 1
P6807 ⁄2 ⁄2 11⁄4 3 P7014 5
⁄8 3
12.7 12.7 31.8 1.4 15.9 1.4
1 3 7
P6808 ⁄4 ⁄8 ⁄8 2 P7016 3
⁄4 4
PrimeAngle

6.4 9.5 22.2 0.9 19.1 1.8


System

1 1
P6809 ⁄4 ⁄2 1 2 P7018 7
⁄8 5
6.4 12.7 25.4 0.9 22.6 2.3
3 1
P6810 ⁄8 ⁄2 11⁄8 3 P7020 1 5
9.5 12.7 28.6 1.4 25.4 2.3
Product
Index

Standard Dimensions for 13⁄16" (21 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: ⁄32" (7.1mm); Hole Spacing - From End: 13⁄32" (10.3mm); Hole Spacing - On Center: 11⁄16" (27.0 mm); Width: 13⁄16"(20.6mm); Thickness: 1⁄8" (3.2mm)
9

13
246 ⁄16" Framing System
®
FIBERGLASS SYSTEMS
Heavy Duty Channel (Flange Profile) ... 250-251
Light Duty Channel (Flange Profile) ..... 252-253
Heavy Duty Channel (SST Profile) ......... 254-255

Nuts & Hardware ..................................... 256-259


Fittings ...................................................... 260-264
Pipe Clamps .............................................. 265-266

Clevis Hangers .................................................. 267


Beam Clamps .................................................... 268
Chemical Compatibility ................................... 269

Specifications ................................................... 270

POLYESTER AND VINYL ESTER MATERIALS OPERATING ENVIRONMENT


Polyester and vinyl ester channels are manufactured from Temperature Ranges – Fiberglass parts are supplied in five
the pultrusion process and are color coded gray and beige different materials covering distinct temperature ranges.
respectively. Components are made by reinforcing a The temperature ranges indicated are meant to be used only
polymer resin (polyester or vinyl ester) with multiple strands as a general guideline. Continual exposure to elevated
of glass filament, alternating layers of glass mat and U.V. temperatures reduces the Material Low High
resistant surfacing veils. The glass is drawn through the strength properties of plastics Code Temp. Temp.
liquid resin, which coats and saturates the fibers. The and glass-reinforced fiberglass. E -25°F 130°F
combination of resin, glass and veil is then continuously Actual resin test data confirms P -35°F 200°F
guided and pulled (pultruded) through a heated die that that a 50% reduction in V -35°F 200°F
PU -40°F 140°F
determines the shape of the component. strength occurs at the extreme N -20°F 150°F
In the die, the resin is cured to form a reinforced part which high temperature levels.
can be cut to length. The hardened fiberglass pultrusion is Chemical Resistance – See the chart on page 269 for
reinforced with an internal arrangement of permanently corrosion resistance. The results are based upon immersion
bonded continuous glass fibers to increase its strength. for a 24 hour period. This is typically the “worst case”
exposure to corrosion. Less severe contact such as spills,
INSTALLATION splashes and vapor condensate will exceed the performance
Fabrication requires just three simple operations: cutting, results listed in the table.
drilling and sealing as described below. Loading – Channel loading is defined with description of
Cutting – Hand held saws, such as hack saws (24 to 32 each type of channel. Additional loading and design
teeth per inch) are suitable when a few cuts are required. limitations for fittings and accessories are described in the
For frequent cutting, a circular power saw with a carbide- appropriate section for that part.
tipped masonry blade yields the best results. When using a
power saw, dust filter masks, gloves and long sleeve cloth-
ing should be worn.
Drilling – Any standard twist bit, even when used with
battery-powered drills will work well. Carbide-tipped drill
bits are recommended.
Sealing – To protect against future migration of corrosive
elements into the cut sections, all cuts and holes should be
properly sealed with clear urethane sealer.

247
® Fiberglass Pictorial Index

Channel - Patented Flange Profile


Channel
15⁄8"

Patented Heavy Duty


Flange
Patented
Telestrut
System

Unistrut fiberglass Flange Profile


channels, except 15⁄8" x 15⁄8"
F20P/V-2000-Pg 250 F20P/V-2100-Pg 250 F20P/V-2200-Pg 250 F20P/V-2300-Pg 250
the SST series, incorporate a patented
flange design which provides reliable
Hardware
Nuts &

fastening and interlocking of


components and accessories. Light Duty
It is important to note that standard Patented
metal framing components such as Flange Profile
General
Fittings

pipe clamps and strut nuts will not 11⁄2" x 11⁄8"


work with the flange design.
F20P/V-1000-Pg 252 F20P/V-1100-Pg 252 F20P/V-1200-Pg 252 F20P/V-1300-Pg 252
Pipe/Conduit
Supports

Channel - SST Profile

Heavy Duty
SST SST Profile
Electrical

Flange
Fittings

15⁄8" x 15⁄8"

F20P/V-2000 SST-Pg 254 F20P/V-2200 SST-Pg 254


F20P/V-2100 SST-Pg 254 F20P/V-23000 SST-Pg 254
The Unistrut SST profile is similar to
Concrete
Inserts

the profile of standard metal channel. The Unistrut SST profile will accommodate standard 15⁄8" metal channel fittings and components.
This profile is available in polyester or vinyl ester resin.
The Unistrut SST profile is not compatible with the fiberglass pipe clamps and channel nuts shown in this section. Typically, stainless steel
clamps and strut nuts (listed elsewhere in this catalog) are used with this profile.
11⁄4" Framing
System

Hardware & Accessories


⁄16" Framing
System
13

Heavy Duty-Pg 256 Standard Duty-Pg 256 Saddle Clip-Pg 256 Stop Lock-Pg 256 Hex Flange Bolt-Pg 257 Hex Bolt-Pg 257
Fiberglass
System
Special
Metals

Hex Flange Nut-Pg 257 Hex Nut -Pg 257 Flat Washer-Pg 258 Spacer -Pg 258 Threaded Rod-Pg 258 Rod Coupler-Pg 258
PrimeAngle
System

End Cap-Pg 259 Capping Strip-Pg 259 U-Bolt-Pg 259


Product
Index

248 Fiberglass
Fiberglass Pictorial Index

Fittings

Channel
15⁄8"
Telestrut
System
F20P/V-2500-Pg 260 F20P/V-2502-Pg 260 F20P/V-2504-Pg 260 F20P/V-2506-Pg 260 F20P/V-2508-Pg 261 F20P/V-2510-Pg 261

Hardware
Nuts &
General
Fittings
F20P/V-2512-Pg 261 F20P/V-2514-Pg 261 F20P/V-2516-Pg 261 F20P/V-2518-Pg 261 F20P/V-2520-Pg 262 F20P/V-2522-Pg 262

Pipe/Conduit
Supports
Electrical
Fittings
F20P/V-2524-Pg 262 F20P/V-2526-Pg 262 F20P/V-2528-Pg 262 F20P/V-2530-Pg 262 F20P/V-2534-Pg 263 F20P/V-2540-Pg 263

Concrete
Inserts
11⁄4" Framing
F20PU-2538-Pg 263 F20PU-2611-Pg 263 F20PU-2613-Pg 263 F50PU-1508 F50PU-2045-Pg 264 F50PU-2636-Pg 264

System
F50PU-2008-Pg 263

Framing
System
13⁄16"
F50PU-2090-Pg 264 F50PU-2616-Pg 264 F20PU-5853 F20PU-5903
F20PU-5855-Pg 264 F20PU-5095-Pg 264

Fiberglass
Pipe Clamps, Beam Clamps and Stanchions

System
Special
Metals

Adj. Pipe Clamp-Pg 265 Rigid Pipe Clamp-Pg 266 Pipe Strap-Pg 266 Fabricated Clevis Molded Clevis
Hanger-Pg 267 Hanger-Pg 267
PrimeAngle
System
Product
Index

Channel Insert-Pg 267 Molded Beam Molded Rack Stanchion-Pg 268


Clamp Assembly-Pg 268 Beam Clamp-Pg 268

Fiberglass 249
® Heavy Duty Channel - Patented Flange Profile

F20P/V-2000 Heavy Duty Single Channel - Patented Flange Profile


Channel

Wt/100 Ft: 82 Lbs(122 kg/100 m)


15⁄8"

15⁄8" 41.3
Telestrut
System

15⁄8" X 41.3 X
Hardware

Y Y
Nuts &
General
Fittings

F20P/V-2100 Heavy Duty Back-to-Back Channel - Patented Flange Profile


Wt/100 Ft: 164 Lbs (244 kg/100 m)
Pipe/Conduit
Supports

15⁄8" 41.3

31⁄4" 82.6
Electrical
Fittings

X X
Concrete
Inserts

Y Y
11⁄4" Framing

F20P/V-2200 Slotted Channel F20P/V-2300 w/Concrete Insert


System

Wt/100 Ft: 82 Lbs (122 kg/100 m) Wt/100 Ft: 88 Lbs (131 kg/100 m)
⁄16" Framing
System
13

Slots are 1" (25.4) x 7⁄16" (11.1)


15⁄8"
Fiberglass

2" (50.8) on Center 15⁄8"


System

(41.3)
(41.3)
15⁄8" 15⁄8"
(41.3)
(41.3)
1⁄4" 23⁄8"
(6.4) (60.3)
Special
Metals

F20P/V-2000, F20P/V-2100 Section Properties


---------------- X - X Axis -------------- -------- Y - Y Axis -------
PrimeAngle

Part Weight Area I R C1 C2 I R C


System

Number lbs./ft. (kg/m) in2 (mm2) in4 (mm4) In (mm) In (mm) In (mm) in4 (mm4) In (mm) In (mm)
F20P/V-2000 0.82 1.06 0.31 0.54 0.7 0.93 0.42 0.63 0.82
1.2 6.8 12.9 13.7 17.8 23.622 17.5 16.0 20.8
F20P/V-2100 1.64 2.12 1.77 0.91 1.63 1.63 0.85 0.63 0.82
Product
Index

2.4 13.7 73.7 23.1 41.4 41.402 35.4 16.0 20.8

250 Fiberglass
Heavy Duty Channel - Flange Profile

F20P/V-2000 Channel Beam/Column Loading

Channel
15⁄8"
Max. Uniform Beam Load Uniform Load at
(Safety Factor - 3:1) Deflection of 1/360 Span Maximum
Span Load Deflection Load Deflection Column Load

Telestrut
System
In (mm) Lbs (kg) In (mm) Lbs (kg) In (mm) Lbs (kg)
12 3,561 0.102 1,159 0.033 5,160
305 1,615 2.6 526 0.8 2,341
18 2,374 0.230 515 0.050 4,704

Hardware
Nuts &
457 1,077 5.8 234 1.3 2,134
24 1,781 0.410 290 0.067 4,168
610 808 10.4 132 1.7 1,891
30 1,424 0.640 185 0.083 3,553

General
Fittings
762 646 16.3 84 2.1 1,612
36 1,187 0.922 129 0.100 2,859
914 538 23.4 59 2.5 1,297

Pipe/Conduit
48 890 1.638 72 0.133 1,636

Supports
1,219 404 41.6 33 3.4 742
60 712 2.560 46 0.167 1,047
1,524 323 65.0 21 4.2 475
72 594 3.686 32 0.200 727

Electrical
Fittings
1,829 269 93.6 15 5.1 330

F20P/V-2100 Channel Beam/Column Loading

Concrete
Max. Uniform Beam Load Uniform Load at

Inserts
(Safety Factor - 3:1) Deflection of 1/360 Span Maximum
Span Load Deflection Load Deflection Column Load
In (mm) Lbs (kg) In (mm) Lbs (kg) In (mm) Lbs (kg)

11⁄4" Framing
12 5,559 0.028 5,559 0.033 9,454

System
305 2,522 0.7 2,522 0.8 4,288
18 3,706 0.064 2,914 0.050 8,866
457 1,681 1.6 1,322 1.3 4,022
24 2,780 0.113 1,639 0.067 8,181

Framing
610 1,261 2.9 743 1.7 3,711

System
30 2,224 0.177 1,049 0.083 7,405
762 1,009 4.5 476 2.1 3,359

13⁄16"
36 1,853 0.254 730 0.100 6,451
914 841 6.5 331 2.5 2,926

Fiberglass
48 1,390 0.452 410 0.133 4,534

System
1,219 630 11.5 186 3.4 2,057
60 1,112 0.707 262 0.167 2,902
1,524 504 18.0 119 4.2 1,316
72 927 1.018 182 0.200 2,015
Special
Metals

1,829 420 25.9 83 5.1 914

F20P/V-2000, F20P/V-2100 FLANGE LOAD Flange Loading


PrimeAngle
System

*Values shown represent a Part Pull-Out Strength*


3:1 safety factor
Number Lbs (kg)
F20V-2000/2100 449
204
Product

F20P-2000/2100 360
Index

163

Fiberglass 251
® Light Duty Channel - Patented Flange Profile

F20P/V-1000 Light Duty Single Channel - Patented Flange Profile


Channel

Wt/100 Ft: 47 Lbs (70 kg/100 m)


15⁄8"
Telestrut

11⁄2" 38.1
System

11⁄8" X 28.6 X
Hardware
Nuts &

Y Y
General
Fittings

F20P/V-1100 Light Duty Back-to-Back Channel - Patented Flange Profile


Wt/100 Ft: 94 Lbs (140 kg/100 m)
Pipe/Conduit
Supports

11⁄2" 38.1

21⁄4" X 57.2
Electrical

X
Fittings

Y Y
Concrete
Inserts
11⁄4" Framing

F20P/V-1200 Slotted Channel F20P/V-1300 w/Concrete Insert


System

Wt/100 Ft: 47 Lbs (70 kg/100 m) Wt/100 Ft: 53 Lbs (79 kg/100 m)
⁄16" Framing
System
13

Slots are 1" (25.4) x 7⁄16" (11.1) 11⁄8"


2" (50.8) on Center
Fiberglass

(28.6) 11⁄2"
11⁄2"
System

(38.1) (38.1)
11⁄8" 1⁄4"
(28.6) 23⁄8"
(6.4)
(60.3)
Special
Metals

F20P/V-1000, F20P/V-1100 Section Properties


---------------- X - X Axis -------------- -------- Y - Y Axis -------
PrimeAngle

Part Weight Area I R C1 C2 I R C


System

Number lbs./ft. (kg/m) in2 (mm2) in4 (mm4) In (mm) In (mm) In (mm) in4 (mm4) In (mm) In (mm)
F20P/V-1000 0.47 0.61 0.1 0.4 0.51 0.62 0.22 0.6 0.75
0.7 3.9 4.2 10.2 13.0 15.748 9.2 15.2 19.1
F20P/V-1100 0.94 1.22 0.42 0.59 1.13 1.13 0.44 0.6 0.75
Product
Index

1.4 7.9 17.5 15.0 28.7 28.702 18.3 15.2 19.1

252 Fiberglass
Light Duty Channel - Flange Profile

F20P/V-1000 Channel Beam/Column Loading

Channel
15⁄8"
Max. Uniform Beam Load Uniform Load at
(Safety Factor - 3:1) Deflection of 1/360 Span Maximum
Span Load Deflection Load Deflection Column Load

Telestrut
System
In (mm) Lbs (kg) In (mm) Lbs (kg) In (mm) Lbs (kg)
12 1,629 0.151 359 0.033 2,759
305 739 3.8 163 0.8 1,251
18 1,086 0.340 160 0.050 2,351

Hardware
Nuts &
457 493 8.6 73 1.3 1,066
24 815 0.605 90 0.067 1,862
610 370 15.4 41 1.7 845
30 652 0.945 57 0.083 1,298

General
Fittings
762 296 24.0 26 2.1 589
36 543 1.360 40 0.100 901
914 246 34.5 18 2.5 409

Pipe/Conduit
48 407 2.418 22 0.133 507

Supports
1,219 185 61.4 10 3.4 230
60 326 3.779 14 0.167 324
1,524 148 96.0 6 4.2 147
72 272 5.441 10 0.200 225

Electrical
Fittings
1,829 123 138.2 5 5.1 102

F20P/V-1100 Channel Beam/Column Loading

Concrete
Max. Uniform Beam Load Uniform Load at

Inserts
(Safety Factor - 3:1) Deflection of 1/360 Span Maximum
Span Load Deflection Load Deflection Column Load
In (mm) Lbs (kg) In (mm) Lbs (kg) In (mm) Lbs (kg)

11⁄4" Framing
12 3,804 0.082 1,556 0.033 5,961

System
305 1,725 2.1 706 0.8 2,704
18 2,536 0.183 691 0.050 5,509
457 1,150 4.6 313 1.3 2,499
24 1,902 0.326 389 0.067 4,979

Framing
610 863 8.3 176 1.7 2,258

System
30 1,522 0.509 249 0.083 4,375
762 690 12.9 113 2.1 1,984

13⁄16"
36 1,268 0.734 173 0.100 3,698
914 575 18.6 78 2.5 1,677

Fiberglass
48 951 1.304 97 0.133 2,254

System
1,219 431 33.1 44 3.4 1,022
60 761 2.038 62 0.167 1,442
1,524 345 51.8 28 4.2 654
72 634 2.935 43 0.200 1,001
Special
Metals

1,829 288 74.5 20 5.1 454

F20P/V-1000, F20P/V-1100 FLANGE LOAD Flange Loading


PrimeAngle
System

*Values shown represent a Pull-Out Strength*


3:1 safety factor
Part Number Lbs (kg)
F20V-1000/1100 213
97
Product
Index

F20P-1000/1100 213
97

Fiberglass 253
® Heavy Duty Channel - Standard Profile

F20P/V-2000 SST Heavy Duty Single Channel - SST Profile


Channel

Wt/100 Ft: 82 Lbs (122 kg/100 m)


15⁄8"

1 5⁄8" 41.3
Telestrut
System

1 5⁄8" X 41.3 X
Hardware

Y
Nuts &

Y
General
Fittings

F20P/V-2100 SST Heavy Duty Back-to-Back Channel - SST Profile


Wt/100 Ft: 164 Lbs (244 kg/100 m)

1 5⁄8" 41.3
Pipe/Conduit
Supports

3 1⁄4" 82.6
X X
Electrical
Fittings

Y Y
Concrete
Inserts
11⁄4" Framing

F20P/V-2200 SST Slotted Channel F20P/V-2300 SST w/Concrete Insert


System

Wt/100 Ft: 82 Lbs (122 kg/100 m) Wt/100 Ft: 88 Lbs (131 kg/100 m)
⁄16" Framing
System
13
Fiberglass
System

Slots are 1" (25.4) x 7⁄16" (11.1)


2" (50.8) on Center 15⁄8" 15⁄8"
(41.3) 15⁄8" (41.3) 15⁄8"
(41.3) (41.3)
1⁄4"
23⁄8"
Special
Metals

(6.4) (60.3)
PrimeAngle
System

NOTE: Unistrut SST Channel is not compatible


with the Unistrut fiberglass pipe clamps and
channel nuts shown in this catalog. Metal clamps
and channel nuts are compatible with this profile
Product

and are shown elsewhere in this catalog.


Index

254 Fiberglass
Heavy Duty Channel - Standard Profile

F20P/V-2000 SST Channel Beam/Column Loading

Channel
15⁄8"
Maximum Uniform Deflection Deflection Uniform Load
Beam Load @ Max. Allowable @ Max. Deflection @ Max. Deflection

Telestrut
System
(Safety Factor - 3:1) Beam Load = 0.25 In (Lbs) = 0.50 In (Lbs) Maximum
Span Poly Vinyl Poly Vinyl Poly Vinyl Poly Vinyl Column Load
In (mm) Lbs (kg) Lbs(kg) In (mm) In (mm) Lbs(kg) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg)
12 1,720 2,150 0.07 0.07 — — — — 3,650

Hardware
Nuts &
305 780 975 1.8 1.8 — — — — 1,655.6
18 1,150 1,440 0.15 0.17 — — — — 3,370
457 522 653 3.8 4.3 — — — — 1,528.6
24 860 1,080 0.27 0.30 810 910 — — 2,960

General
Fittings
610 390 490 6.9 7.6 367.4 412.8 — — 1,342.6
30 690 870 0.42 0.48 410 460 — — 2,450
762 313 395 10.7 12.2 186.0 208.7 — — 1,111.3

Pipe/Conduit
36 580 730 0.61 0.69 240 270 480 540 1,800

Supports
914 263 331 15.5 17.5 108.9 122.5 217.7 244.9 816.5
48 430 540 1.07 1.20 100 115 200 230 1,010
1,219 195 245 27.2 30.5 45.4 52.2 90.7 104.3 458.1
60 350 440 1.70 1.91 60 70 120 135 260

Electrical
1,524 159 200 43.2 48.5 27.2 31.8 54.4 61.2 117.9

Fittings
72 290 370 2.44 2.78 30 34 60 70 NR
1,829 132 168 62.0 70.6 13.6 15.4 27.2 31.8 NR

Concrete
Inserts
F20P/V-2100 SST Channel Beam/Column Loading

11⁄4" Framing
System
Maximum Uniform Deflection Deflection Uniform Load
Beam Load @ Max. Allowable @ Max. Deflection @ Max. Deflection
(Safety Factor - 3:1) Beam Load = 0.25 In (Lbs) = 0.50 In (Lbs) Maximum
Span Poly Vinyl Poly Vinyl Poly Vinyl Poly Vinyl Column Load

Framing
In (mm) Lbs (kg) Lbs(kg) In (mm) In (mm) Lbs(kg) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg)

System
12 5,080 6,350 0.04 0.04 — — — — 7,300
305 2,304 2,880 1.0 1.0 — — — — 3,311.2

13⁄16"
18 3,390 4,240 0.09 0.10 — — — — 6,740
457 1,538 1,923 2.3 2.5 — — — — 3,057.2
24 2,540 3,180 0.16 0.17 — — — — 5,920

Fiberglass
System
610 1,152 1,442 4.1 4.3 — — — — 2,685.3
30 2,040 2,550 0.24 0.27 — 2,350 — — 4,900
762 925 1,157 6.1 6.9 — 1,065.9 — — 2,222.6
36 1,700 2,130 0.35 0.39 1,220 1,370 — — 3,600
Special
Metals

914 771 966 8.9 9.9 553.4 621.4 — — 1,632.9


48 1,270 1,590 0.62 0.69 520 590 1,040 1,170 2,020
1,219 576 721 15.7 17.5 235.9 267.6 471.7 530.7 916.3
PrimeAngle

60 1,020 1,280 0.97 1.09 270 310 540 610 520


System

1,524 463 581 24.6 27.7 122.5 140.6 244.9 276.7 235.9
72 850 1,070 1.40 1.57 160 180 320 360 NR
1,829 386 485 35.6 39.9 72.6 81.6 145.1 163.3 NR
Product
Index

Fiberglass 255
® Fiberglass Channel Nuts & Accessories

Heavy Duty Channel Nuts Saddle Clips


Channel
15⁄8"

Heavy duty channel nuts are designed to Saddle clips mate with the exterior of the channel flanges and are
be used where high thread shear values secured with threaded rods and nuts.
or spring nuts are required. They can
not be used with light duty 1000 series Material: glass-reinforced polyurethane.
Telestrut
System

channel or SST profile channel.


Material: glass-reinforced polyurethane.
Hardware

Part Thread Shear Torque Wt/100 pcs


Nuts &

Number Size Lbs (kg)* Ft/Lbs (N•m ) Lbs (kg)


3
F375PU-CNHD ⁄8"-16 1,400 8 5.7
635 11 2.6
1
F500PU-CNHD ⁄2"-13 1,400 8 5.3
General
Fittings

635 11 2.4
5
F625PU-CNHD ⁄8"-11 1,400 10 5.1 Part Size Wt/100 pcs
635 14 2.3 Number (In.) Lbs (kg)
3
F750PU-CNHD ⁄4"-10 1,400 10 4.4 F200-4226 3
⁄8 3.5
Pipe/Conduit

635 14 2.0 1.6


Supports

F10PU-CNMHD 10 mm 1,400 8 5.8 F200-4217 1


⁄2 2.5
635 11 2.6 1.1
F12PU-CNMHD 12 mm 1,400 8 5.5 F200-4341 5
⁄8 3.0
635 11 2.5 1.4
F16PU-CNMHD 16 mm 1,400 10 5.3 F200-4342 3
⁄4 2.5
Electrical

635 14 2.4
Fittings

1.1
F20PU-CNMHD 20 mm 1,400 10 4.4
635 14 2.0
*Thread shear values shown represent a 3:1 safety factor. Stop-Lock Assemblies
Concrete
Inserts

Stop-Lock Assemblies reduce the chance of pipe slippage when


running supports vertically and are recommended for applications
that are subject to vibration, have
regular contact with fluids or are
vertically mounted. The Stop-Locks fit
Standard Duty Channel Nuts
11⁄4" Framing

both sizes of channel.


System

Standard Duty channel nuts are designed for Material: glass-reinforced


light duty applications that do not require polyurethane.
high thread shear values. They can be
used with both light duty series 1000 and
heavy duty series 2000 fiberglass channel.
Hex Head
⁄16" Framing

Not for use with SST profile channel.


Flange Bolt
System

Material: glass-reinforced polyurethane.


Saddle Clip
Channel Nut
13

Part Thread Shear Torque Wt/100 pcs


Number Size Lbs (kg)* Ft/Lbs (N•m ) Lbs (kg)
Fiberglass
System

1
F250PU-CN ⁄4"-20 460 2 1.8
209 3 0.8
5
F312PU-CN ⁄16"-18 460 2 1.7
209 3 0.8 Force
3
F375PU-CN ⁄8"-16 460 3 1.8 Part Size Resistance Torque Wt/100 pcs
Special
Metals

209 4 0.8 Number (in.) Lbs (kg)* Ft/Lbs (N•m ) Lbs (kg)
1
F500PU-CN ⁄2"-13 460 3 1.4 3
F200-4227 ⁄8" 200 7 6.3
209 4 0.6
91 9 2.9
F10PU-CN 10 mm 460 3 1.7 1
F200-4219 ⁄2" 220 12 6.4
PrimeAngle

209 4 0.8 100 16 2.9


System

F12PU-CN 12 mm 460 3 1.4 5


F200-4343 ⁄8"** 250 15 11.0
209 4 0.6 113 20 5.0
F10PU-CNS #10 Screw 460 N/A 1.9
209 0.9 * Force resistance values shown represents a 3:1 safety
factor.
Product

*Thread shear values shown represent a 3:1 safety factor.


Index

** Supplied with a heavy duty channel nut for use only


with the heavy duty series 2000 channel.

256 Fiberglass
Fiberglass Hardware

Hex Flange Bolts Hex Bolts

Channel
15⁄8"
Fiberfast bolts are ideal for mechanical
connections that require a high
degree of corrosion resistance. The Fiberfast bolts are ideal for mechani-
3 Shoulder cal connections that require a high Shoulder
⁄8" diameter fasteners are recom-

Telestrut
System
mended for all channel fitting Length degree of corrosion resistance. The Length
3
mechanical connections. ⁄8" diameter fasteners are recom-
mended for all channel fitting
Material: glass-reinforced polyurethane. mechanical connections.
Material: glass-reinforced polyure-

Hardware
Nuts &
thane.

Thread Shank Shoulder Thread Shank Shoulder


Part Size Shear Shear Length Torque Wt/100 pcs Part Size Shear Shear Length Torque Wt/100 pcs

General
Fittings
Number (in.) Lbs (kg)* Lbs (kg)* In (mm) Ft/Lbs (N•m ) Lbs (kg) Number (in.) Lbs (kg)* Lbs (kg)* In (mm) Ft/Lbs (N•m ) Lbs (kg)
1
F250PU-075 ⁄4 x3⁄4 110 210 Full Thread 0.8 .4 F375PU-125 3⁄8 x 11⁄4 250 470 Full Thread 3 1.0
50 95 1 0.2 113 213 4 0.5
1
F250PU-100 ⁄4 x 1 110 210 Full Thread 0.8 .5 F375PU-150 3⁄8 x 11⁄2 250 470 1
⁄4 3 1.1
50 95 1 .02 113 213 6 4 0.5

Pipe/Conduit
Supports
1
F250PU-150 ⁄4 x 11⁄2 110 210 1
⁄2 0.8 .6 F375PU-200 3⁄8 x 2 250 470 1
⁄2 3 1.3
50 95 13 1 0.3 113 213 13 4 0.6
1
F500PU-125 ⁄2 x 11⁄4 450 870 Full Thread 8 1.0 F375PU-250 3⁄8 x 21⁄2 250 470 3
⁄4 3 1.6
204 395 11 0.5 113 213 19 4 0.7
1
F500PU-150 ⁄2 x 11⁄2 450 870 Full Thread 8 1.1 F375PU-300 3⁄8 x 3 250 470 1 3 1.8
204 395 11 .05 113 213 25 4 0.8

Electrical
Fittings
1 3
F500PU-200 ⁄2 x 2 450 870 ⁄4 8 1.3 F625PU-125 5⁄8 x 11⁄4 700 1,360 1
⁄4 12 2.5
204 395 19 11 0.6 318 617 6 16 1.1
1
F500PU-250 ⁄2 x 21⁄2 450 870 Full Thread 8 1.6 F625PU-150 5⁄8 x 11⁄2 700 1,360 1
⁄4 12 2.8
204 395 11 0.7 318 617 6 16 1.3

Concrete
1
F500PU-300 ⁄2 x 3 450 870 1 8 1.8 F625PU-200 5⁄8 x 2 700 1,360 1
⁄4 12 3.2

Inserts
204 395 25 11 0.8 318 617 6 16 1.5
1
F500PU-350 ⁄2 x 31⁄2 450 870 23⁄16 8 2.0 F625PU-250 5⁄8 x 21⁄2 700 1,360 1
⁄4 12 3.4
204 395 56 11 0.9 318 617 6 16 1.5
*Thread shear values shown represent a 3:1 safety factor. F625PU-300 5⁄8 x 3 700 1,360 1
⁄4 12 3.9

11⁄4" Framing
318 617 6 16 1.8

System
F625PU-350 5⁄8 x 31⁄2 700 1,360 11⁄4 12 5.5
318 617 6 16 2.5
*Thread shear values shown represent a 3:1 safety factor.

Framing
Hex Flange Nuts Hex Nuts

System
The hex flange nut is preferred for applica-

13⁄16"
tions that require additional thread
engagement (such as with all-thread rod)
or maximum thread shear strength.

Fiberglass
Material: glass-reinforced polyurethane.

System
Thread Thread
Part Size Shear Height Torque Wt/100 pcs Part Size Shear Height Torque Wt/100 pcs
Number (in.) Lbs (kg)* In (mm) Ft/Lbs (N•m ) Lbs (kg) Number (in.) Lbs (kg)* In (mm) Ft/Lbs (N•m ) Lbs (kg)
Special
Metals

3 1
F375PU-FN-000 ⁄8-16 500 0.750 3 0.8 F250PU-000 ⁄4-20 150 0.218 0.8 0.1
227 19.1 4 0.4 68 5.5 1 0.05
1 3
F500PU-FN-000 ⁄2-13 1,200 0.855 8 1.6 F375PU-000 ⁄8-16 460 0.328 3 0.3
544 21.7 11 0.7 209 8.3 4 0.1
PrimeAngle
System

5 1
F625PU-FN-000 ⁄8-11 2,200 1.220 12 3.5 F500PU-000 ⁄2-13 800 0.437 8 0.5
998 31.0 16 1.6 363 11.1 11 0.2
3 5
F750PU-FN-000 ⁄4-10 2,900 1.590 15 5.5 F625PU-000 ⁄8-11 1,000 0.546 12 1.5
1,315 40.4 20 2.5 454 13.9 16 0.7
*Thread shear values shown represent a 3:1 safety factor. *Thread shear values shown represent a 3:1 safety factor.
Product
Index

Fiberglass 257
® Fiberglass Hardware

Flat Washers F50PU-500SP Channel Spacers


Channel

Wt/100 pcs: 2.0 Lbs (.91 kg)


15⁄8"

Channel spacers are designed to prevent wall compression under


Material: PVC heavy loading conditions. Such loading occurs during the
torquing of hardware for channel fittings.
Telestrut

Note: PVC washers are recommended


System

for connections that utilize hex nuts The spacers are designed to be used only with 15⁄8" channels and
and bolts. will accommodate 3⁄8" and 1⁄2" bolts.
Material: molded from polyurethane
Hardware
Nuts &

Outside
Part Size Diameter Wt/100 pcs
Number (in.) In (mm) Lbs (kg)
General
Fittings

1
F250E-999 ⁄4 0.49 0.1
12.4 0.05
3
F375E-999 ⁄8 1.00 0.1
25.4 0.05
Pipe/Conduit

1
F500E-999 ⁄2 1.25 0.5
Supports

31.8 0.2
5
F625E-999 ⁄8 1.50 0.5
38.1 0.2
3
F750E-999 ⁄4 1.50 1.0
38.1 0.5
Electrical

F1000E-999 1 2.25 1.5


Fittings

57.2 0.7
Concrete
Inserts

Threaded Rod A-Konnector Rod Couplers


A-Konnectors provide an excellent means for extending FRP
all-thread rods beyond their standard lengths. A-Konnectors
are manufactured from glass-reinforced polyurethane and are
11⁄4" Framing

colored gray. A-Konnectors are packaged in bags containing


System

25 pieces.
⁄16" Framing

Material: pultruded vinyl ester resin and is gray in color.


System

Thread Wt/100 pcs


13

Part Size Weight Shear Torque 4' in Len.


Number (in.) Lbs (kg) Lbs (kg)* Ft/Lbs (N•m ) Lbs (kg)
Fiberglass

3
F200-3827 ⁄8-16 0.07 415 5 35
System

0.03 188 7 15.9


1 Thread
F200-3828 ⁄2-13 0.12 570 10 57
Part Size Length Shear Wt/100 pcs
0.05 259 14 25.9
5 Number (in.) In (mm) Lbs (kg)* Lbs (kg)
F200-3829 ⁄8-11 0.18 1,260 40 91
3
F200-3840 ⁄8-16 21⁄4 800 6.5
Special

0.08 572 54 41.3


Metals

F200-3830 3
⁄4-10 0.28 1,700 50 133
57.2 363 2.9
1
0.13 771 68 60.3 F200-3841 ⁄2-13 21⁄4 870 6.0
F200-3831 1-8 0.50 3,000 60 200
57.2 395 2.7
5
0.23 1,361 81 90.7 F200-3842 ⁄8-11 21⁄4 1,500 13.0
PrimeAngle

57.2 680 5.9


System

* Thread shear values shown represent a 3:1 safety factor. F200-3843 3


⁄4-10 21⁄4 1,500 11.0
** Standard lengths are 4' and 8'. 57.2 680 5.0
The part number shown is for 4' lengths. * Thread shear values shown represent a 3:1 safety
To order eight foot lengths, add suffix “-96” factor.
to part number (Example: F200-3827-96)
Product
Index

258 Fiberglass
Fiberglass Hardware and Accessories

FAIC-EC Channel End Cap F20E-5000 Channel Capping Strip

Channel
Wt/100 Ft: 5 Lbs (7.4 kg/100 m)

15⁄8"
Wt/100 pcs: 3.4 Lbs (1.5 kg)

Telestrut
System
Hardware
Nuts &
Supplied in 10
Material: red PVC and designed for 15⁄8" channel. foot lengths.
End caps are desired when the ends of the channel
need to be enclosed. The cap easily installs by

General
Fittings
pressing it onto the end of the channel opening.
Material: PVC
Installs simply by pressing it onto the
channel opening. It is designed to be used

Pipe/Conduit
when a cover is desired for the channel

Supports
opening (such as concrete embedment
channel).

Nonmetallic U-Bolts

Electrical
Unistrut Nonmetallic U-Bolts provide a corrosion resistant alterna-

Fittings
tive to traditional metallic U-Bolts. They have oversized diameters
which allow them to hold steel conduit and plastic pipe. These
bolts will outlast stainless steel in most corrosive applications.
Each U-Bolt comes with two polyurethane hex nuts. Additional nuts

Concrete
and washers can be purchased separately. D

Inserts
Material: glass-reinforced polyurethane C
TL

11⁄4" Framing
Note: Plate not included.

System
B A Illustration purpose only

Part Size “A” Dim. “B” Dim. “C” Dim. “D” Dim. “TL” Dim. Load Torque Wt/100 pcs
Number In In (mm) In (mm) In (mm) In (mm) In (mm) Lbs (kg)* In/Lbs (N•m ) Lbs (kg)
1
FUB-050 ⁄2 0.937 0.375 1.568 2.412 1.25 135 40 3

Framing
23.8 9.5 39.8 61.3 31.8 61 5 1.4

System
3
FUB-075 ⁄4 1.125 0.375 1.662 2.600 1.25 135 40 3
28.6 9.5 42.2 66.0 31.8 61 5 1.4

13⁄16"
FUB-100 1 1.375 0.375 1.787 2.850 1.25 135 40 4
34.9 9.5 45.4 72.4 31.8 61 5 1.8
FUB-125 11⁄4 1.687 0.375 1.943 3.162 1.25 135 40 4

Fiberglass
42.8 9.5 49.4 80.3 31.8 61 5 1.8

System
FUB-150 11⁄2 2.000 0.375 2.100 3.475 1.25 135 40 5
50.8 9.5 53.3 88.3 31.8 61 5 2.3
FUB-200 2 2.437 0.500 2.468 4.187 1.50 135 80 10
61.9 12.7 62.7 106.3 38.1 61 9 4.5
FUB-250 21⁄2 2.937 0.500 2.718 4.687 1.50 135 80 11
Special
Metals

74.6 12.7 69.0 119.0 38.1 61 9 5.0


FUB-300 3 3.562 0.500 3.031 5.312 1.50 135 80 14
90.5 12.7 77.0 134.9 38.1 61 9 6.4
FUB-350 31⁄2 4.062 0.500 3.281 5.812 1.50 135 80 15
PrimeAngle

103.2 12.7 83.3 147.6 38.1 61 9 6.8


System

FUB-400 4 4.562 0.500 3.531 6.312 1.50 135 80 16


115.9 12.7 89.7 160.3 38.1 61 9 7.3
FUB-600 6 6.750 0.625 5.750 9.875 3.25 135 120 17
171.5 15.9 146.1 250.8 82.6 61 14 7.7
Product

*Torque and load values shown represent a 3:1 safety factor.


Index

Fiberglass 259
® Flat Fiberglass Fittings

Channel Fittings
Channel
15⁄8"

Channel Fittings are required to fabricate structures and are easily


attached to Channels with channel nuts and polyurethane
fasteners. The fittings are offered in two types; fabricated (cut
from flat stock) or molded.
Telestrut
System

Material (Fabricated Fittings): Either polyester (P Series) or


vinyl ester (V Series) material.
Material (Molded Fittings): All molded fittings with the exception Patented SST
of the post bases are molded in polyurethane. Flange Flange
Hardware
Nuts &

Note: The drawings for all fittings are shown with the patented
flange profile, however they can be used with either channel
profile.
General
Fittings
Pipe/Conduit
Supports

F20P-2500, F20V-2500 Wt/100 pcs: 12 Lbs (5.4 kg) F20P-2502, F20V-2502 Wt/100 pcs: 17 Lbs (7.7 kg)
Electrical
Fittings

47⁄8"
(123.8)
Concrete
Inserts
11⁄4" Framing
System

31⁄4"
(82.6)
⁄16" Framing
System

F20P-2504, F20V-2504 Wt/100 pcs: 24 Lbs (10.9 kg) F20P-2506, F20V-2506 Wt/100 pcs: 32 Lbs (14.5 kg)
13
Fiberglass
System

61⁄2"
(165.1) 81⁄8"
Special
Metals

(206.4)
PrimeAngle
System
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: 13⁄32" (10.3 mm) , Accommodates 3⁄8" hardware; Hole Spacing - On Center: 15⁄8" (41 mm); Width: 15⁄8"(41mm); Thickness: 3⁄8" (9.5mm)

260 Fiberglass
Flat Fiberglass Fittings
Fiberglass Fittings

F20P-2508, F20V-2508 Wt/100 pcs: 17 Lbs (7.7 kg) F20P-2510, F20V-2510 Wt/100 pcs: 25 Lbs (11.3 kg)

Channel
15⁄8"
Telestrut
System
Hardware
Nuts &
47⁄8"
31⁄4" (123.8)
(82.6)

General
Fittings
31⁄4"
(82.6) 31⁄4"
(82.6)

Pipe/Conduit
Supports
F20P-2512, F20V-2512 Wt/100 pcs: 26 Lbs (11.8 kg) F20P-2514, F20V-2514 Wt/100 pcs: 20 Lbs (9.1 kg)

Electrical
Fittings
Concrete
Inserts
47⁄8" 31⁄4"

11⁄4" Framing
(123.8) (82.6)
31⁄4"

System
(82.6)

31⁄4"
(82.6)

Framing
System
F20P-2516, F20V-2516 Wt/100 pcs: 32 Lbs (14.5 kg) F20P-2518, F20V-2518 Wt/100 pcs: 33 Lbs (15.0 kg)

13⁄16"
Fiberglass
System
Special
Metals

47⁄8" 31⁄4" 47⁄8"


PrimeAngle

(123.8) (82.6)
(123.8)
System

7
4 ⁄8"
(123.8)
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: 13⁄32" (10.3 mm) , Accommodates 3⁄8" hardware; Hole Spacing - On Center: 15⁄8" (41 mm); Width: 15⁄8"(41mm); Thickness: 3⁄8" (9.5mm)

Fiberglass 261
® Fiberglass Fittings

F20P-2520, F20V-2520 Wt/100 pcs: 45 Lbs (20.4 kg) F20P-2522, F20V-2522 Wt/100 pcs: 21 Lbs (9.5 kg)
Channel
15⁄8"

47⁄8"
Telestrut
System

(123.8)
31⁄4"
(82.6)
Hardware

47⁄8"
Nuts &

(123.8)
General
Fittings

31⁄4"
(82.6)
Pipe/Conduit
Supports

F20P-2524, F20V-2524 Wt/100 pcs: 32 Lbs (14.5 kg) F20P-2526, F20V-2526 Wt/100 pcs: 45 Lbs (20.4 kg)
Electrical
Fittings
Concrete
Inserts

31⁄4" 47⁄8"
(149.2)
(82.6)
11⁄4" Framing
System

47⁄8" 47⁄8"
(123.8) (149.2)
⁄16" Framing
System

F20P-2528, F20V-2528 Wt/100 pcs: 20 Lbs (9.1 kg) F20P-2530, F20V-2530 Wt/100 pcs: 50 Lbs (22.7 kg)
13
Fiberglass
System

51⁄4"
(133.4)
35⁄8"
(92.1)
Special
Metals

8 1 ⁄ 8"
(206.4)
PrimeAngle
System

31⁄4"
(136.5)
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: 13⁄32" (10.3 mm) , Accommodates 3⁄8" hardware; Hole Spacing - On Center: 15⁄8" (41 mm); Width: 15⁄8"(41mm); Thickness: 3⁄8" (9.5mm)

262 Fiberglass
Fiberglass Fittings

F20P-2534, F20V-2534 Wt/100 pcs: 77 Lbs (34.9 kg) F20P-2540, F20V-2540 Wt/100 pcs: 41 Lbs (18.6 kg)

Channel
15⁄8"
Telestrut
System
Hardware
81⁄8"

Nuts &
(206.4)
51⁄4"
45° (133.4)

General
Fittings
51⁄4"
(133.4)

47⁄8"
(123.8)

Pipe/Conduit
Supports
F50PU-2538 Wt/100 pcs: 57 Lbs (26.0 kg) F50PU-2611 Wt/100 pcs: 9 Lbs (4.1 kg)

Electrical
Fittings
Concrete
Inserts
4"
(101.6)

11⁄4" Framing
31⁄2"

System
(88.9)
17⁄8"
5" (47.6)
(127.0) 15⁄8"
(41.3)

Framing
System
F50PU-2613 Wt/100 pcs: 16 Lbs (7.3 kg) F50PU-1508 (11⁄2"), F50PU-2008 (15⁄8")
Wt/100 pcs: 27 Lbs (12.2 kg)

13⁄16"
513⁄32"
(137.3)

Fiberglass
System
Special
Metals

47⁄8"
PrimeAngle

17⁄8" (123.8)
System

25⁄32" (47.6)
(54.8) 47⁄8"
(123.8)
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: 13⁄32" (10.3 mm) , Accommodates 3⁄8" hardware; Hole Spacing - On Center: 15⁄8" (41 mm); Width: 15⁄8"(41mm); Thickness: 3⁄8" (9.5mm)

Fiberglass 263
® Fiberglass Fittings

F50PU-2045 (15⁄8") Wt/100 pcs: 35 Lbs (15.9 kg) F50PU-2636 Wt/100 pcs: 14 Lbs (6.4 kg)
Channel
15⁄8"
Telestrut
System

4"
(41.3)
Hardware
Nuts &
General
Fittings

41⁄2"
51⁄2" (114.3)
(139.7)
15⁄8"
(41.3)
Pipe/Conduit
Supports

F50PU-2090 (15⁄8") Wt/100 pcs: 35 Lbs (15.9 kg) F50PU-2616 Wt/100 pcs: 51 Lbs (23.1 kg)

47⁄8"
(123.8) 17⁄8"
Electrical

(47.6)
Fittings

47⁄8"
Concrete
Inserts

(123.8)

25⁄32"
(54.8)
11⁄4" Framing

71⁄4"
System

(184.2)
⁄16" Framing
System

F20PU-5853 (15⁄8"), F20PU-5855 (11⁄8") F20PU-5903 (31⁄4"), F20PU-5905 (21⁄4")


Wt/100 pcs: 71 Lbs (32.2 kg) Wt/100 pcs: 86 Lbs (39.0 kg)
13
Fiberglass
System

3"
(127.0) 3"
Special
Metals

(76.2)
PrimeAngle
System

5" 5" 6 5⁄8"


(127.0) (168.3) 5"
(127.0) (127.0)
Product
Index

Standard Dimensions for 15⁄8" (41 mm) width series channel fittings (Unless Otherwise Shown on Drawing)
Hole Diameter: 13⁄32" (10.3 mm) , Accommodates 3⁄8" hardware; Hole Spacing - On Center: 15⁄8" (41 mm); Width: 15⁄8"(41mm); Thickness: 3⁄8" (9.5mm)

264 Fiberglass
Fiberglass Pipe Clamps

Fiberglass Clamps Design Load Information

Channel
15⁄8"
There are two types of piping system loadings, overhead (Type 1)
and vertical (Type 2) as described below. All pipe straps and
clamps show the recommended loading for both types of loading.

Telestrut
System
Type 1 Overhead Design Load Type 2 Vertical Design Load
The design load shown represents pipes supported below the The design loading shown can be
strut. The design loads shown are based on a minimum ultimate achieved with the addition of a
failure safety factor of 3:1. vertical stop lock assembly (Part

Hardware
#F200-4219) installed directly

Nuts &
beneath the pipe clamp. The
adjacent illustration shows how the
vertical stop lock assembly provides
additional support for pipe and how
it can be used to achieve full Type 2

General
Fittings
design loads.
Design loads are based on a minimum
clamp slip safety factor or 3:1. It is
recommended that stop lock

Pipe/Conduit
assemblies be used for all vertical

Supports
pipe support applications.

Adjustable Pipe Clamps

Electrical
Unistrut Adjustable Pipe Clamps are manufactured from glass-

Fittings
reinforced polyurethane and are adjustable to accommodate a
wide range of outside diameters. They can be utilized with a
variety of piping systems including: PVC, fiberglass, copper, rigid
steel conduit and PVC coated rigid steel conduit.

Concrete
Care should be taken not to exceed 3 ft./lbs. of torque on the

Inserts
adjustable pipe straps.

11⁄4" Framing
System
Framing
System
13⁄16"
Design Load
Part O.D. Pipe Type 1 Type 2 Torque Wt/100 pcs

Fiberglass
System
Number Size (in.) Lbs (kg) Lbs (kg) Ft/Lbs (N•m ) Lbs (kg)
1
200-3100 ⁄2 –11⁄2 135 65 0.8 3
61 29 1 1.4
200-3110 11⁄2 –21⁄4 135 65 3 5
61 29 4 2.3
Special
Metals

200-3120 21⁄4 –31⁄4 145 70 3 5


66 32 4 2.3
200-3130 3–4 215 70 3 8
98 32 4 3.6
PrimeAngle

200-3140 4–61⁄2 215 70 3 10


System

98 32 4 4.5
*Design loads shown represent a 3:1 safety factor.
Product
Index

Fiberglass 265
® Fiberglass Pipe Clamps

Rigid Pipe Clamps


Channel
15⁄8"

PVC, Sch. 80 Design Loads* FRP Bolt


Part Nominal & Rigid Metal Type 1 Type 2 FRP Bolt Torque Wt/100 pcs
Number Size (in.) In (mm) Lbs (kg) Lbs (kg) Size (in.) Ft/Lbs (N•m ) Lbs (kg)
Telestrut
System

1 3
FPCR-050 ⁄2 0.840 225 90 ⁄8 x 11⁄4 3 3
21.336 102 41 4 1.4
3 3
FPCR-075 ⁄4 1.050 225 90 ⁄8 x 11⁄4 3 3
26.67 102 41 4 1.4
3
FPCR-100 1 1.315 225 90 ⁄8 x 11⁄4 3 4
Hardware

33.401 102 41 4 1.8


Nuts &

FPCR-125 11⁄4 1.660 225 90 3


⁄8 x 11⁄4 3 5
42.164 102 41 4 2.3
FPCR-150 11⁄2 1.900 225 90 3
⁄8 x 11⁄4 3 5
48.26 102 41 4 2.3
General
Fittings

3
FPCR-200 2 2.375 225 90 ⁄8 x 11⁄4 3 5
60.325 102 41 4 2.3
FPCR-250 21⁄2 2.875 225 90 3
⁄8 x 11⁄4 3 7 Rigid Pipe Clamps resemble the more
73.025 102 41 4 3.2 traditional style of pipe clamps and are
FPCR-300 3 3.500 225 90 3
⁄8 x 11⁄4 3 10 sized based on the pipe inside diameter
Pipe/Conduit

or nominal size.
Supports

88.9 102 41 4 4.5


3
FPCR-400 4 4.500 300 125 ⁄8 x 11⁄4 3 12 Polyurethane clamps are recommended
114.3 136 57 4 5.4 for applications up to 160°F. For high
3
FPCR-600 6 6.625 300 125 ⁄8 x 11⁄4 3 15 temperature applications (up to 230°F).
168.275 136 57 4 6.8
3
Care should be taken not to exceed the
FPCR-800 8 8.625 300 125 ⁄8 x 11⁄4 3 18 recommended torque values of the
Electrical
Fittings

219.075 136 57 4 8.2 rigid pipe clamps.


*Design loads shown represent a 3:1 safety factor. Material: glass-reinforced polyurethane.

Two Hole Pipe Straps


Concrete
Inserts

Bolt Material Design Load


Part Dim. A Dim. B Size Thick. Type 1 Type2 Torque Wt/100 pcs
No. In (mm) In (mm) (in.) In (mm) Lbs (kg) Lbs (kg) Ft/Lbs (N•m ) Lbs (kg)
1 1
FPS200 2.375 6.375 ⁄2 ⁄4 135 50 4 14
11⁄4" Framing

60.33 161.93 6.4 61 23 5 6.4


System

1 1
FPS250 2.875 6.875 ⁄2 ⁄4 135 50 4 17
73.03 174.63 6.4 61 23 5 7.7
1 1
FPS300 3.500 7.500 ⁄2 ⁄4 135 50 4 20
88.90 190.50 6.4 61 23 5 9.1
1 1
FPS350 4.000 8.000 ⁄2 ⁄4 135 50 4 33
101.60 203.20 6.4 61 23 5 15.0
⁄16" Framing

1 1
FPS400 4.500 8.500 ⁄2 ⁄4 175 60 4 23
System

114.30 215.90 6.4 79 27 5 10.4


1 1
FPS500 5.563 9.563 ⁄2 ⁄4 175 60 4 39
141.30 242.90 6.4 79 27 5 17.7
13

1 1
FPS600 6.625 10.625 ⁄2 ⁄4 175 60 4 39
168.28 269.88 6.4 79 27 5 17.7
Fiberglass

1 1
FPS800 8.625 12.625 ⁄2 ⁄4 225 125 4 51
System

219.08 320.68 6.4 102 57 5 23.1 A


5 1 B
FPS1000 10.750 15.750 ⁄8 ⁄4 225 125 10 77
273.05 400.05 6.4 102 57 14 34.9 Two Hole Pipe Straps are designed for use in
5 1
FPS1200 12.750 16.250 ⁄8 ⁄4 225 125 10 83 securing pipe, conduit and ducts to Channel.
323.85 412.75 6.4 102 57 14 37.6 Two hole fiberglass straps can also be used
Special
Metals

5 3
FPS1400 14.000 18.000 ⁄8 ⁄8 250 150 10 125 independently from the channel for surface
355.60 457.20 9.5 113 68 14 56.7 mounting. All sizes of the straps are suitable for
FPS1600 16.000 20.000 5
⁄8 3
⁄8 250 150 10 143 load bearing applications.
406.40 508.00 9.5 113 68 14 64.9 Material: fire-retardant, glass-reinforced polyester
PrimeAngle

5 3
FPS1800 18.000 23.000 ⁄8 ⁄8 250 150 10 160 resin.
System

457.20 584.20 9.5 113 68 14 72.6


For extreme chemical environments, the straps can
*Design loads shown represent a 3:1 safety factor. be manufactured from vinyl ester resin. Larger
Notes: diameter straps for special applications are also
(1) Bolts and channel nuts are sold separately. available. Contact the factory for pricing and
(2) When bolting onto 15⁄8" channel a 11⁄4" long bolt is req'd. availability of vinyl ester and large diameter
Product

straps. Two hole pipe straps should not be


Index

torqued above recommended values.

266 Fiberglass
Fiberglass Clevis Hangers

Molded Clevis Hangers

Channel
Nominal Max. Hanger

15⁄8"
Part Diameter Pipe O.D. “A” Dim. “B” Dim. “C” Dim. Rod Load* Wt/100 pcs
C Number In (mm) In (mm) In (mm) In (mm) In (mm) In (mm) Lbs (kg) Lbs (kg)
1 1
FCVHPU-100 ⁄2 - 1 1 1.500 4.25 1.25 ⁄2 670 29

Telestrut
System
12.7 - 25.4 25.4 38.1 108.0 31.8 12.7 304 13.2
FCVHPU-150 11⁄4- 11⁄2 11⁄2 2.000 5.14 1.25 1
⁄2 670 40
31.8 - 38.1 38.1 50.8 130.6 31.8 12.7 304 18.1
B
FCVHPU-200 11⁄2 - 2 2 2.500 6.52 1.25 1
⁄2 730 43

Hardware
38.1 - 50.8 50.8 63.5 165.6 31.8 12.7 331 19.5

Nuts &
C FCVHPU-400 21⁄2 - 4 4 5.125 10.00 1.50 1
⁄2 1,150 129
63.5 - 101.6 101.6 130.2 254.0 38.1 12.7 522 58.5
FCVHPU-600 41⁄2 - 6 6 6.750 12.33 1.50 1
⁄2 1,170 168
114.3 - 152.4 152.4 171.5 313.2 38.1 12.7 531 76.2

General
Fittings
Material: glass-reinforced polyurethane. *Design load values shown represent a 3:1 safety factor.

Fabricated Clevis Hangers


Size Range Hanger Trans Spreader

Pipe/Conduit
Part In (mm) ....... Dimensions - In (mm) ..... Rod Rod Rod O.D. Loads* Wt/100 pcs

Supports
Number A T H H1 W In (mm) In (mm) In (mm) Lbs (kg) Lbs (kg)
F100-1500 1–11⁄2 1
⁄8 23⁄4 17⁄8 1 1⁄2 1
⁄2 3
⁄8 1
⁄2 60 21
25–38 3 70 48 38 13 10 13 27 9.5
W F100-1501 11⁄2–2 1
⁄8 31⁄2 23⁄8 1 1⁄2 1
⁄2 3
⁄8 1
⁄2 60 25
T 38–51 3 89 60 38 13 10 13 27 11.3
H

Electrical
Fittings
F100-1502 2–25⁄8 1
⁄8 43⁄4 3 2 1
⁄2 3
⁄8 1
⁄2 90 55
51–67 3 121 76 51 13 10 13 41 24.9
F100-1503 21⁄2–31⁄4 1
⁄8 51⁄2 35⁄8 2 1
⁄2 3
⁄8 1
⁄2 120 57
H1 64–83 3 140 92 51 13 10 13 54 25.9
F100-1504 3–37⁄8 1
⁄8 7 41⁄4 2 5
⁄8 3
⁄8 1
⁄2 160 61

Concrete
Inserts
76–98 3 178 108 51 16 10 13 73 27.7
F100-1505 4–51⁄8 13
⁄16 81⁄2 55⁄8 2 5
⁄8 3
⁄8 1
⁄2 250 82
A 102–130 21 216 143 51 16 10 13 113 37.2
F100-1506 6–71⁄8 13
⁄16 107⁄8 71⁄2 3 5
⁄8 3
⁄8 1
⁄2 300 136
152–181 21 276 191 76 16 10 13 136 61.7

11⁄4" Framing
F100-1507 8–91⁄4 1
⁄4 14 93⁄4 3 5
⁄8 3
⁄8 1
⁄2 350 189

System
Material: glass-reinforced 203–235 6 356 248 76 16 10 13 159 85.7
polyester resin. F100-1508 10–113⁄8 1
⁄4 18 12 4 5
⁄8 1
⁄2 3
⁄4 450 333
254–289 6 457 305 102 16 13 19 204 151.0
F100-1509 12–131⁄2 1
⁄4 211⁄2 141⁄8 5 5
⁄8 1
⁄2 3
⁄4 600 350
305–343 6 546 359 127 16 13 19 272 158.8

Framing
F100-1510 14–153⁄4 1
⁄4 241⁄2 161⁄2 5 3
⁄4 1
⁄2 3
⁄4 700 872

System
356–400 6 622 419 127 19 13 19 318 395.5
3
F100-1511 16–18 ⁄8 273⁄8 191⁄2 6 3
⁄4 3
⁄4 1 750 1,023

13⁄16"
406–457 10 695 495 152 19 19 25 340 464.0
3
F100-1512 19–21 ⁄8 341⁄2 221⁄2 6 3
⁄4 3
⁄4 1 800 1,673
483–533 10 876 572 152 19 19 25 363 758.9

Fiberglass
1
F100-1513 21–22 ⁄2 351⁄2 24 6 3
⁄4 3
⁄4 1 850 2,323

System
533-559 13 902 610 152 19 19 25 386 1,053.7
*Design load values shown 1 3 3
represent a 3:1 safety factor. F100-1514 22–24 ⁄2 41 28 6 ⁄4 ⁄4 1 900 2,973
533-610 13 1,041 711 152 19 19 25 408 1,348.5 Special

F200-4101 Unisert Channel Insert


Metals

Wt/100 pcs: 1.0 Lbs (.5 kg)


Unisert is a polyurethane nonmetallic insert which can be used with
standard cable ties for securing tubing, conduit and cables to
standard metal channels.
PrimeAngle
System

The Unisert works with all 15⁄8" channels that are 13⁄16" deep or
more. One size fits 12, 14 and 16 metal gauge channels.
Note: For use only with metallic channel.
Product
Index

Fiberglass 267
® Fiberglass Beam Clamps, Power-Rack Stanchions

F375PU & F500PU Molded Beam Clamps FRGBC Molded Beam Clamp Assembly
Channel
15⁄8"

Material: glass-reinforced
polyurethane
25⁄8"
(66.7)
F375PU-BCCLP (3⁄8")
Telestrut
System

Beam Clip Only


3"
(76.2)
Note: Beam clamp clip must
be purchased separately.
Hardware
Nuts &

3⁄4" Illustration purpose only


(19.0) Material: glass-reinforced polyurethane.
Thread
Part Size Shear Torque Wt/100 pcs
Assembly Thread Number In Lbs (kg)* Ft/Lbs (N•m ) Lbs (kg)
General
Fittings

Part Size Shear Torque Wt/100 pcs 3


FRGBC-1 ⁄8 500 10 43
Number In Lbs (kg)* Ft/Lbs (N•m ) Lbs (kg) 227 14 19.5
3
F375PU-BC ⁄8 400 10 30 FRGBC-2 1
⁄2 500 10 43
181 14 13.6 227 14 19.5
Pipe/Conduit

1
F500PU-BC ⁄2 400 10 30 FRGBC-3 5
⁄8 500 10 43
Supports

181 14 13.6 227 14 19.5


*Design load values shown represent a 3:1 safety factor. *Design load values shown represent a 3:1 safety factor.

Power-Rack Stanchions
Electrical
Fittings

The Power-Rack Stanchion is made entirely from glass-reinforced


nylon, these stanchions offer greater corrosion resistance than
classical metal stanchions. The interlocking design allows the
arm to “lock” into nine different levels on the 141⁄4" stanchions
and fourteen on the 171⁄2" stanchion. Glass-reinforced polyure-
Concrete
Inserts

thane stanchions are available as a special order. Contact


Unistrut for pricing and availability.

Dimensions – The stanchion back has 9⁄16" x 15⁄16" holes to


11⁄4" Framing

accept fasteners for mounting. There are two mounting holes in


the 213⁄8" long stanchion and three in the 335⁄16" long stanchion.
System

Thickness at the slotted mounting holes is 17⁄8". The mounting


holes are spaced on 12" centers and require 1⁄2" diameter
fasteners.

Installation – The Stanchions can be anchored into existing


⁄16" Framing

concrete structures using any industrial anchoring system. For


System

new concrete structures, the Stanchions can be mounted to


fiberglass concrete embedment channel and attached with 1⁄2"
channel nuts and 1⁄2"x 3" Fiberfast Bolts.
13

Fire Retardance – Power-Rack materials meet or exceed the


Fiberglass

requirements of UL94 HB.


System

Loading – The recommended allowable loads on Power-Rack Size Wt/100 pcs Load (lbs.)*
Stanchions vary depending upon the position of the arm. Use Part No. Description In (mm) Lbs (kg) Lbs (kg)
these guidelines for a safe, reliable installation:
F20N-ARM08 Arm 8 100 800
Special
Metals

• Total load on any one arm should not exceed 800 lbs. 203 45.4 363
F20N-ARM14 Arm 141⁄4 116 800
• The sum of the loads on an arm multiplied by their distances 362 52.6 363
to the wall stanchion should not exceed 1200 in./lbs. F20N-ARM17 Arm 171⁄2 145 800
PrimeAngle

445 65.8 363


System

Example: A cable weighing 200 lbs. is positioned on an arm at F20N-ARM23 Arm 23 7⁄8 186 800
a distance of 5" from the wall stanchion. 606 84.4 363
F20N-STA21 Stanchion 213⁄8 149 N/A
If the total load is less than 800 lbs and the sum of the load 543 67.6
multiplied by their distances to the wall stanchion does not F20N-STA33 Stanchion 335⁄16 231 N/A
Product

exceed 1200 in./lbs., then the system is adequate. In this case,


Index

846 104.8
Total load (200<800 lbs) = OK *Design load values shown represent a 3:1 safety factor.
Tot. moment (200x5 in. = 1000<1200 in./lbs.) = OK
268 Fiberglass
Fiberglass Technical Data

Chemical Compatibility Table

Channel
...................... Series ..................... ...................... Series .....................

15⁄8"
E P V PU N E P V PU N
Rigid Poly Vinyl Rigid Poly Vinyl
PVC /Glass /Glass Poly Nylon PVC /Glass /Glass Poly Nylon

Telestrut
Chemical 70°-160°F 70°-160°F 70°-160°F 70°-160°F 70°-160°F Chemical 70°-160°F 70°-160°F 70°-160°F 70°-160°F 70°-160°F

System
Acetic Acid, Up to 10% R R R R R R R – nr nr Hydrofluoric Acid,
Up to 50% R R R R R R R – nr nr Up to 10% R R nr nr R 150° – – – –
Acetone, Up to 10% nr nr nr nr nr nr R – R R Up to 20% R nr nr nr R 100° – – – –
Aluminum Hydroxide R R R R R R R – nr nr Hydrogen Chloride

Hardware
Wet Gas nr nr R nr R R nr – – –

Nuts &
Ammonium Hydroxide
(Aqueous Ammonia), Hydrogen Sulfide
Up to 5% R R nr nr R R R – – – Wet Gas R R R nr R R R – – –
Up to 10% R R nr nr R 150° R – – – Lactic Acid R R R nr R R R – – –
Ammonium Hydroxide, Lead Nitrate R R – – R R R – – –

General
Fittings
Up to 20% R R nr nr R 150° R – – – Magnesium Hydroxide R R nr nr R R R – R R
Ammonium Nitrate R nr R R R R R – – – Nickel Sulfate, Low pH R R nr nr R R R – – –
Ammonium Phosphate R R R nr R R R – – – Nickel Sulfate, High pH R R nr nr R R R – – –
Ammenium Sulfide, Nitric Acid,
saturated R R nr nr R 120° R – – – Up to 5% R R nr nr R 150° R – – –

Pipe/Conduit
Supports
Aqua Regia, fumes nr nr nr nr R 150° nr – – – Up to 35% R R nr nr R 150° R – – –
Benzene nr nr nr nr nr nr R R – R Nitric Acid, Vapor R R nr nr R R R – – –
Benzoic Acid R R R R R R R – – – Perchloric Acid,
Bromine, wet gas R nr nr nr R 100° – – – – Up to 10% nr nr nr nr R 150° R – nr nr
Butylene Glycol, Pickling Liquids,
Up to 100% R R R R R R R – R R 3-5% H2S04 R R R R R R R – – –

Electrical
Fittings
Butyric Acid, Phosphoric Acid R R nr nr R R R – nr nr
Up to 50% nr nr R R R R R – – – Super or Poly
Calcium Hydroxide R R R nr R R R – – – (115%, P20%) R R nr nr R R R – – –
Vapor or Condensate R R nr nr R R R – – –
Calcium Hypochlorite R R R nr R R R – nr nr
Potassium Chloride R R R R R R R – – –
Chlorine, Dry Gas nr nr nr nr R R – – – –

Concrete
Potassium Nitrate R R R R R R R – – –

Inserts
Chlorine, Wet Gas nr nr nr nr R R – – – –
Potassium Persulfate R R nr nr R R R – – –
Chlorine, Liquid nr nr nr nr nr nr – – – –
Silver Cyanide, Up to 5% R R nr nr R R R – – –
Chlorine, Water nr nr R R R R R – nr nr
Sodium Hydroxide,
Chromic Acid,
Up to 25% R R nr nr R 150° R – – –
Up to 5% R R nr nr R R – – R R

11⁄4" Framing
Sodium Hydroxide,
Copper Chloride R R R R R R R – – –

System
Up to 50% R R nr nr R 180° R – R R
Copper Cyanide R R R nr R R R – – –
Sodium Hypochlorite,
Copper Fluoride R R R nr R R R – – – Up to 15% R R nr nr R 150° R – nr nr
Copper Nitrate R R R R R R R – – Sodium Nitrate R R R R R R R – – –
Copper Sulfate R R R R R R R – – – Sodium Sulfate R R R nr R R R – – –
Dechlorinated Brine Storage R R – – R R R – –

Framing
Sodium Sulfide R R nr nr R R R – – –

System
Sulfuric Acid
Esters, Fatty Acid nr nr R R R R R – – – Up to 25% R R R R R R R – nr nr
Ferric Chloride R R R R R R R – – – Up to 50% R R nr nr R R R – – –

13⁄16"
Ferrous Chloride R R R R R R R – – – Up to 70% R R nr nr R R R – nr nr
Fluoboric Acid R R R 120° R R – – – – Up to 75% nr nr nr nr R 120° R – nr nr
Fluosilicic Acid, Up to 10%nr nr nr nr R R – – nr nr Up to 80% nr nr nr nr nr nr nr – nr nr
Vapor R R R nr R R R – – –

Fiberglass
Up to 32% nr nr nr nr R 100° – – – –

System
Formic Acid Up to 10% R R nr nr R R R – nr nr Trichlorethylene, Fumes nr nr nr nr R 120° R – – –
Up to 50% R R nr nr R 100° R – – – Trisodium Phosphate R R R nr R R R – – –
Gasoline, Aviation R nr R nr R R R – – – Urea R R R nr R 150° R – R R
Green Liquor, Pulp Mill R R – – R R – – – – Vegetable Oils R R R R R R R – R R
Hydrochloric Acid Vinegar R R R R R R R R R R
Special
Metals

Up to 15% R R R nr R R R – – – White Liquor, Pulp Mill R R – – R R R – – –


Up to 37% R R R nr R R R – – –

Note
PrimeAngle
System

The recommendations contained in this table are made without guarantee of representation as to Legend
results. Since the actual use by others is beyond our control, no guarantee, expressed or implied, is
made by Unistrut as to effects of such use or results to be obtained nor does Unistrut assume any
liability arising out of the use by others of the products referenced in this table. Nor is the “nr“ - “Not Recommended” for use
information herein to be construed as absolutely complete since additional information may be
needed or desirable when particular or exceptional conditions or circumstances exist or because of “R“ - “Recommended”
Product

applicable laws or government regulations. We suggest that you evaluate these recommendations
Index

and suggestions in your own laboratory prior to use. Our responsibility for claims arising from “–“ - no information available
breach of warranty, negligence, or otherwise is limited to the purchase price of the material.

Fiberglass 269
® Fiberglass Sample Specifications

Fiberglass Specifications
Channel
15⁄8"

1.0 SCOPE 5.0 STANDARDS


Telestrut
System

1.1 This specification covers the requirements for 5.1 Glass-reinforced channels covered in this
the Unistrut Nonmetallic Channel Framing specification shall have a flame spread rating of
System. 25 or less when tested per ASTM E84 and meet
Hardware

the requirements of UL 94V0 thereby qualifying


Nuts &

2.0 MATERIAL them as Class 1 material in the Uniform Building


Code.
2.1 FRP channel shall be of pultruded glass-rein-
General
Fittings

forced polyester or vinyl ester resin having the 5.2 Glass-reinforced channels covered in this specifi-
physical property values listed in this catalog. cation shall comply with the requirements of
ASTM D 3917 and ASTM D 4385 which govern
2.2 Some accessories shall be of injection molded,
the dimensional tolerance and visual defects of
Pipe/Conduit

40% long glass fiber reinforced polyurethane, or


Supports

pultruded shapes.
nylon.

6.0 GENERAL
3.0 COMPOSITION
6.1 Unistrut nonmetallic Channel Framing shall be
Electrical
Fittings

3.1 Glass-reinforced channel shall have a synthetic


furnished as a system which includes all the
surfacing veil applied on exterior surfaces to
necessary fasteners, channel splice plates,
improve weatherability and inhibit ultraviolet
brackets, sealants, hangers, pipe clamps, etc.
degradation. An ultraviolet stabilizer shall be
Concrete
Inserts

incorporated in the resin formulation to further 6.2 Nonmetallic fasteners shall be manufactured
inhibit ultraviolet degradation. from long glass fiber reinforced polyurethane to
ensure maximum strength and corrosion resis-
tance.
11⁄4" Framing

4.0 STRUCTURAL DESIGN


System

4.1 Channel shall incorporate Unistrut's patented 6.3 All components of the Unistrut Channel Framing
flange profile design which allows full and System shall be nonmetallic except where type
positive interlocking contact of channel accesso- 316 stainless steel hardware is used as part of the
ries and prohibits premature flange failure from assembly.
⁄16" Framing

torqued accessories.
System

6.4 The manufacturer shall not have had less than 10


4.2 Channel profile dimensions shall be: years experience in manufacturing strut systems.
13

15⁄8" x 15⁄8" x 1⁄4" or 6.5 All products are manufactured in the United
11⁄2" x 11⁄8" x 1⁄8". States of America.
Fiberglass
System

4.3 All 15⁄8" x 15⁄8" channel profiles shall have a


minimum pull out resistance of 1,000 pounds
when load is applied over a 3⁄8" long section of
Special
Metals

the inside flanges.

4.4 Channel section lengths shall be supplied in 10'


or 20' lengths (± 1⁄8").
PrimeAngle
System

4.5 Universal Pipe Clamps shall have full interlocking


contact with interior channel flanges to maxi-
mize pull-out resistance and be adjustable to
accommodate a minimum 3⁄4" variance in piping
Product
Index

or conduit O.D. sizes.

270 Fiberglass
®
SPECIAL METALS
Stainless Steel .......................................... 273-275
Aluminum ................................................. 276-278

MATERIAL LOAD DATA (SLIP & PULL OUT)

Stainless Steel Extruded Aluminum


Channels:ASTM A 240 (Type 304) To determine nut slip resistance, multiply load data for
appropriate nut by 75%. To determine nut pull-out
Sintered nuts: ASTM B783 (Type 316N2-33)
load, multiply load data for appropriate nut by 50%.
Fittings:
Stainless Steel
ASTM A240 (Type 304) or ASTM A276 (Type 304)
For design assistance, consult Unistrut customer
Type 316 stainless also available for most products. engineering.
Contact factory for specific material availability.

Aluminum
PRODUCT AVAILABILITY
Channels (Extruded): ASTM B221 (Type 6063-T6) Most fittings and channels shown in this catalog, are
available in aluminum or stainless steel. Consult factory for
Fittings: ASTM B209 (Type 1100F or Type 5052-H32)
ordering information.
Nuts: ASTM B221 (Type 6063-T5)

DIMENSIONS
LOAD DATA (BEAM & COLUMN)
Imperial dimensions are illustrated in inches. Metric
To determine maximum allowable beam and column dimensions are shown in parenthesis or as noted. Unless
loading for channels in this section, multiply the load data in noted, all metric dimensions are in millimeters and rounded
the appropriate mild steel channel sections of this catalog by to one decimal place.
the following factors:
CHANNEL BEAM LOAD COLUMN LOAD
MATERIAL % FACTOR % FACTOR

EXTRUDED ALUMINUM 33.0% 33.0%


STAINLESS STEEL 100.0% 100.0%

271
® Special Metals Pictorial Index

P1000 Series (12 gauge) P1100 Series (14 gauge) P3000 Series (12 gauge)
Channel
15⁄8"
Telestrut
System

P1000 SS P1001 SS P1100 SS P1101 SS P3000 SS


Hardware

Pg 273 Pg 273 Pg 273 Pg 273 Pg 273


Nuts &

P3300 Series (12 gauge) P4000 Series (16 gauge) P6000 Series (19 gauge)
General
Fittings

P3300 SS P3301 SS P4000 SS P6000 SS


Pipe/Conduit

Pg 273 Pg 273 Pg 274 Pg 274


Supports

P7000 Series (19 gauge) Closure Strips and End Caps


Electrical
Fittings
Concrete

P7000 SS P1184 SS P3184 EA P1280 EA, P4280 EA,


Inserts

Pg 274 Pg 274 Pg 278 P5580 EA Pg 278

Stainless Steel Channel Nuts


11⁄4" Framing
System

UNISTRU
T

U R
UNIST
⁄16" Framing

P1006 U - P1010U P4006 U - P4010U P5506 U - P5510U P4010 UT A1006 SS, A1008 SS A4006 SS, A4008 SS A5506 SS, A5508 SS
Pg 275 Pg 275 Pg 275 Pg 275 Pg 275 Pg 275 Pg 275
System

Extruded Aluminum Channels


13
Fiberglass
System
Special

P1000 EA P1001 EA P4000 EA P4001 EA P5500 EA A1000 EA A4000 EA A4001 EA


Metals

Pg 276 Pg 276 Pg 276 Pg 276 Pg 276 Pg 277 Pg 277 Pg 277


PrimeAngle
System

P6000 EA P6001 EA P7000 EA P7001 EA


Pg 277 Pg 277 Pg 278 Pg 278
Product
Index

272 Special Metals


Stainless Steel

P1000 Series

Channel
15⁄8"
Telestrut
System
Hardware
Nuts &
P1000 SS P1001 SS P1000HS SS P1000T SS

General
Fittings
Wt/100 Ft: 190 Lbs Wt/100 Ft: 380 Lbs Wt/100 Ft: 185 Lbs Wt/100 Ft: 185 Lbs
(283 kg/100m) (566 kg/100m) (275 kg/100m) (275 kg/100m)

P1100 Series

Pipe/Conduit
Supports
Electrical
Fittings
P1100 SS P1101 SS P1100HS SS P1100T SS

Concrete
Inserts
Wt/100 Ft :142 Lbs Wt/100 Ft : 284 Lbs Wt/100 Ft : 136 Lbs Wt/100 Ft: 136 Lbs
(211 kg/100m) (422 kg/100m) (202 kg/100m) (202 kg/100m)

P3000 Series

11⁄4" Framing
System
Framing
System
13⁄16"
P3000 SS P3000HS SS P3000T SS
Wt/100 Ft: 170 Lbs Wt/100 Ft: 165 Lbs Wt/100 Ft: 165 Lbs

Fiberglass
(253 kg/100m) (112 kg/100m) (112 kg/100m)

System
P3300 Series
Special
Metals
PrimeAngle
System
Product
Index

P3300 SS P3301 SS P3300HS SS P3300T SS


Wt/100 Ft: 135 Lbs Wt/100 Ft: 270 Lbs Wt/100 Ft: 130 Lbs Wt/100 Ft: 130 Lbs
(201 kg/100m) (402 kg/100m) (193 kg/100m) (193 kg/100m)

Special Metals 273


® Stainless Steel

P4000 Series
Channel
15⁄8"
Telestrut
System
Hardware
Nuts &

P4000HS SS P4000T SS
P4000 SS Wt/100 Ft: 79 Lbs Wt/100 Ft: 79 Lbs
Wt/100 Ft: 82 Lbs (122 kg/100m) (110 kg/100m) (110 kg/100m)
General
Fittings

P6000 SS Wt/100 Ft: 37 Lbs (55 kg/100m) P7000 SS Wt/100 Ft: 36 Lbs (54 kg/100m)
Pipe/Conduit
Supports
Electrical
Fittings
Concrete
Inserts

P1184 SS Closure Strip


11⁄4" Framing
System

Use
Part With “W” Wt/100 Ft
W Number Channel In (mm) Lbs (kg/m)
P1000
P1184 SS P1100 15⁄8 27
⁄16" Framing

P3300 41.3 40.2


System

P4000
13

Standard length 10 Ft.


Material: Stainless steel type 304.
Fiberglass
System
Special
Metals
PrimeAngle
System
Product
Index

274 Special Metals


Stainless Steel Channel Nuts

For Use With 15⁄8" Channel


Channel nut Wt/100 pcs P1000, P1100, P3300, P4000

Channel
Part number Nut Size -Thread Lbs (kg) P2000, P3000 P4100 P5500

15⁄8"
1
P1006U-1420 ⁄4" -20 7 ■ – –
3.2
3
P1008U ⁄8" -16 10 ■ – –

Telestrut
System
4.5
1
P1010U ⁄2" -13 12 ■ – –
5.4
Material: Sintered type 316 stainless steel with pre-galvanized spring.

Hardware
Nuts &
1
P4006U-1420 ⁄4" -20 7 – ■ –
3.2
3
P4008U ⁄8" -16 9 – ■ –
4.1

General
Fittings
1
P4010U ⁄2" -13 9 – ■ –
4.1
Material: Sintered type 316 stainless steel with pre-galvanized spring.

Pipe/Conduit
Supports
1
P5506U-1420 ⁄4" -20 7 – – ■
3.2
3
P5508U ⁄8" -16 10 – – ■
4.5

Electrical
1

Fittings
P5510U ⁄2" -13 10 – – ■
4.5
Material: Sintered type 316 stainless steel with pre-galvanized spring.

Concrete
1
P4006-1420T SS ⁄4" -20 7 ■ – ■

Inserts
UNISTRU
T
3.2
1
UNIST
RU
T
P4008UT ⁄2" -13 12 ■ – ■
5.4
1
P4010UT ⁄2" -13 8 – ■ –

11⁄4" Framing
3.6

System
For Use With Channel
Channel nut Wt/100 pcs P3300, P4000
Part number Nut Size -Thread Lbs (kg) A1000 A4100 A5000

Framing
1
A1006-1420 SS ⁄4" -20 6 ■ – –

System
2.7
3
A1008 SS ⁄8" -16 6 ■ – –

13⁄16"
2.7
Material: Sintered type 304 stainless steel with pre-galvanized spring.
1
A4006-1420 SS ⁄4" -20 5 – ■ –

Fiberglass
System
2.3
3
A4008 SS ⁄8" -16 5 – ■ –
2.3
Material: Sintered type 304 stainless steel with pre-galvanized spring.
Special
Metals

1
A5506-1420 SS ⁄4" -20 6 – – ■
2.7
3
A5508 SS ⁄8" -16 6 – – ■
2.7
PrimeAngle
System

Material: Wrought type 304 stainless steel with pre-galvanized spring.

Note
Product
Index

Most fittings, as shown in this catalog are available in stainless steel or aluminum. It is recommended that stainless steel
channel nuts be used with aluminum channels.

Special Metals 275


® Extruded Aluminum Channels

P1000 EA Wt/100 Ft: 76 Lbs (113 kg/100 m)


Channel

Aluminum Type 6063-T6


15⁄8"

When used Nominal Thickness .109" (2.8mm)


1 5⁄8" 41.3 with P3184 EA.

7 22.2
⁄8"
Telestrut

9.5
System

3 3 9.5
⁄8" ⁄8"

1 5⁄8" 41.3
Hardware
Nuts &

P1001 EA Wt/100 Ft: 134 Lbs (199 kg/100 m)


Aluminum Type 6063-T6
12 Gauge Nominal Thickness .109" (2.8mm)
1 5⁄8" 41.3
General
Fittings

7 22.2
3 ⁄8" 3 9.5 9.5
⁄8" ⁄8"
Pipe/Conduit
Supports

82.6
3 1⁄4"
Electrical
Fittings

P4000 EA Wt/100 Ft: 45 Lbs (67 kg/100 m)


Aluminum Type 6063-T6
Nominal Thickness .078" (2.0mm)
Concrete
Inserts

1 5⁄8" 41.3

7
⁄8" 22.2
3 3 9.5 9.5
⁄8" ⁄8"
11⁄4" Framing

20.6
System

13
3
⁄16"
2.8
.078" .109" 2.0

P4001 EA Wt/100 Ft: 66 Lbs (98 kg/100 m)


⁄16" Framing

Aluminum Type 6063-T6


System

Nominal Thickness .078" (2.0mm)


1 5⁄8" 41.3
13

7 22.2
3
⁄8" 3 9.5 9.5
⁄8" ⁄8"
Fiberglass
System

1 5⁄8" 41.3
Special
Metals

P5500 EA Wt/100 Ft: 97 Lbs (144 kg/100 m)


Aluminum Type 6063-T6
Nominal Thickness .109" (2.8mm)
1 5⁄8" 41.3
PrimeAngle

7 22.2
⁄8"
System

3
3
⁄8" ⁄8" 9.5 9.5

2 7⁄16" 61.9
Product
Index

276 Special Metals


Extruded Aluminum Channels

A1000 EA Wt/100 Ft: 40 Lbs (60 kg/100 m)

Channel
Aluminum Type 6063-T6

15⁄8"
Nominal Thickness .075" (1.9mm)
1
⁄4 " 31.8

11
1 17.5
⁄16"

Telestrut
9
⁄32"

System
9 7.1 7.1
⁄32"

1 1⁄4" 31.8

Hardware
Nuts &
A4000 EA Wt/100 Ft: 25 Lbs (37 kg/100 m)
Aluminum Type 6063-T6
12 Gauge Nominal Thickness .050" (1.3mm)

General
Fittings
Standard Length 16 Ft.
1 1⁄4" 31.8

11
1 17.5
9
⁄32" ⁄16" 9
⁄32" 7.1 7.1

Pipe/Conduit
Supports
5
⁄8" 15.9

.050" .075" 1.3 1.9

A4001 EA Wt/100 Ft: 40 Lbs (60 kg/100 m)


Aluminum Type 6063-T6

Electrical
Fittings
Nominal Thickness .078" (2.0mm)
Standard Length 16 Ft.
1 1⁄4" 31.8

11
1 17.5
⁄16"

Concrete
9 9 7.1
⁄32" ⁄32" 7.1

Inserts
1 1⁄4" 31.8

11⁄4" Framing
System
P6000 EA Wt/100 Ft: 12 Lbs (18 kg/100 m)
Aluminum Type 6063-T6
Nominal Thickness .040" (1.0mm)
Standard Length 16 Ft.
13
3 20.6
⁄16"

Framing
11.1

System
7
3 ⁄16" 3 4.8 4.8
⁄16" ⁄16"

13⁄16"
13
3 20.6
⁄16"

Fiberglass
System
P6001 EA Wt/100 Ft: 20 Lbs (30 kg/100 m)
Aluminum Type 6063-T6
Nominal Thickness .040" (1.0mm)
Special
Metals

Standard Length 16 Ft.


13
3
⁄ " 20.6

16" 11.1
3 3 4.8 4.8
⁄16" ⁄16"
PrimeAngle
System

1 5⁄8" 41.3
Product
Index

Special Metals 277


® Extruded Aluminum Channels

P7000 EA Wt/100 Ft: 9 Lbs (13 kg/100 m)


Channel

Aluminum Type 6063-T6


15⁄8"

Nominal Thickness .040" (1.0mm)


20.6 Standard Length 10 Ft.
13
3
⁄16"
Telestrut

11.1
System

7
3 ⁄16" 3
⁄16" 4.8 4.8
⁄16"
10.3
13
⁄32"
Hardware
Nuts &

P7001 EA Wt/100 Ft: 17 Lbs (25 kg/100 m)


Aluminum Type 6063-T6
12 Gauge Nominal Thickness .040" (1.0mm)
General
Fittings

13
3
Standard Length 10 Ft
⁄16" 20.6

7
3
⁄16" ⁄16" 3 11.1
⁄16" 4.8 4.8
Pipe/Conduit
Supports

13
3 20.6
⁄16"
Electrical
Fittings

P3184 EA Closure Strip


Concrete

Wt/100 Ft: 21 Lbs (31 kg/100 m)


Inserts

Aluminum Type 6063-T6


Standard Length 10 Ft
11⁄4" Framing
System

1 5⁄8"
(41.3)
⁄16" Framing
System
13

P1280 EA, P4280 EA, P5580 EA End Caps


Fiberglass
System

Part Use With Wt/100 Ft


Special
Metals

Number Channel Lbs(kg/m)


P1280 EA P1000 EA 3.5
1.6
P4280 EA P4000 EA 1.5
PrimeAngle

0.7
System

P5500 EA P5500 EA 4.9


2.2
Product
Index

278 Special Metals


®
PRIMEANGLE™
PrimeAngle™ .................................................... 280
Accessories ........................................................ 281
PrimeAngle™ Technical Data ................. 282-284

MATERIAL ORDERING INFORMATION:


STEEL: PLAIN When ordering, add the length or size and finish to the
12 Gauge (.105" 1.0 mm) and 14 Gauge (.076) part number.
ASTM 1011 SS GR 33
STEEL: PRE-GALVANIZED
12 Gauge (.105" 1.0 mm) and 14 Gauge (.076) DIMENSIONS
ASTM A653 GR 33 Imperial dimensions are illustrated in inches. Metric
dimensions are shown in parenthesis or as noted. Unless
noted, all metric dimensions are in millimeters and rounded
FINISHES to one decimal place.

Available in two durable, long-lasting finishes.


Pre-galvanized (PG) or Perma–Green (GR) conforming to
ASTM B633 Type III SC1.

STANDARD LENGTHS
Standard lengths are 10' and 12'. Slotted angle is shipped in
ten-piece bundles complete with 75 pieces of 3⁄8" - 16 x 3⁄4"
hex head bolts and 3⁄8" nuts.

279
® Prime Angle and Accessories

PA 158 Light Duty


Channel
15⁄8"

(15⁄8" x 15⁄8" x 14 ga.) Wt/100 Ft.: 66 lbs (29.9 kg)


Telestrut
System

For those jobs where extra strength is


not necessary. Ideal for light-duty
shelving or racking.
Hardware
Nuts &

15⁄8"
11⁄2" (41.3)
General

(38.1)
Fittings

3
⁄4"
Note: Includes Serrated (19.1) 3
Nuts & Bolts ⁄4" 15⁄8"
(19.1) (41.3)
Pipe/Conduit
Supports

PA 238 Medium Duty


(15⁄8" x 23⁄8" x 14 ga.) Wt/100 Ft: 80 lbs(36.3 kg)
Electrical
Fittings

Perfect for the majority of framing


Concrete

needs, including shelving, racking and


Inserts

electrical or mechanical support jobs.

15⁄8" (41.3)

11⁄2"
11⁄4" Framing

(38.1)
System

3
⁄4" 23⁄8"
Note: Includes Serrated (19.1) ⁄4"
3
(60.3)
Nuts & Bolts (19.1)
Framing
System

PA 318 Heavy Duty


(15⁄8" x 31⁄8" x 12 ga.) Wt/100 Ft: 130 lbs (59.0 kg)
13⁄16"
Fiberglass
System

Suitable for balconies, ramps, large racks and


shelving systems, as well as other structures
with substantial load requirements.
Special
Metals

15⁄8"
(41.3)
PrimeAngle
System

11⁄2"
(38.1)
Note: Includes Serrated 31⁄8"
Nuts & Bolts 3
⁄4" (79.4)
(19.1) ⁄4"
3

(19.1)
Product
Index

280 PrimeAngle
Prime Angle and Accessories

PA 1HDC Portable Cutter PA 1GP Gusset Plate

Channel
Wt/100 pcs: 17 lbs (7.7 kg) Wt/100 pcs: 9 lbs (4.1 kg)

15⁄8"
Telestrut
System
Hardware
Nuts &
General
Fittings
PA 1SC Swivel Caster PA 1RC Rigid Caster
Wt/100 pcs: 170 lbs (77.1 kg) Wt/100 pcs: 110 lbs (49.9 kg)

Pipe/Conduit
Supports
Electrical
Fittings
Concrete
Inserts
PA 1SNB Serrated Nuts and Bolts PA 1RP Slotted Strap
Wt/100 pcs: 7 lbs (3.2 kg) Wt/100 pcs: 35 lbs (15.9 kg)

11⁄4" Framing
System
Framing
System
13⁄16"
Transverse Stiffeners

Fiberglass
System
When supporting concentrated loads, the capacity of a pair of For maximum effectiveness, transverse stiffeners should never be
slotted-angle beams can be increased by the addition of trans- spaced more than 3’6" (106.7 cm) apart.
verse stiffeners. These should be placed immediately under the
load bearing point. The slotted-angle segment used as the Note: All loads based on actual physical testing. Documentation
Special
Metals

stiffener is bolted into place using a metal connector at each available on request.
junction.

Beams that are 6' (182.9 cm) long or less require only one
PrimeAngle

stiffener in the center of the span. Seven-foot beams need two


System

stiffeners placed 2' (61.0 cm) from each end. Eight-ffot beams
require two stiffeners 2’6" (76.2 cm) from the ends. For beams
with a nine-foot span, it is necessary to have three stiffeners at
2’3" (68.6 cm) intervals. Ten-foot beams need three stiffeners
with 2’6" spacings.
Product
Index

PrimeAngle 281
® Prime Angle Beam Loads

Beam Configurations (See corresponding letters in table on following page for load data)
Channel
15⁄8"

G – Two Single H – Two Single I – Two Single J – Two Z-Sections K – Two Narrow
Pieces (Up) Pieces (Level) Pieces (Down) Channels
Telestrut
System
Hardware
Nuts &

L – Two Broad Channels M – Two T-Sections N – Two I-Section O – Two J-Sections


General
Fittings
Pipe/Conduit
Supports

Beam Configurations With Stiffeners (See corresponding letters in table on following page for load data)
Electrical

P – Single Pieces w/Stiffner Q – T-Sections w/Stiffener R – Z-Sections w/Stiffener R – I-Sections w/Stiffener


Fittings
Concrete
Inserts
11⁄4" Framing
System

Beam Load Calculations


The beam loading depends on which slotted angle is used and Example - Load “C”
the manner in which the beam is constructed. The diagrams
Load “C” is supported by all four beam
above show how individual slotted angle components can be
sections. The load is distributed
Framing

combined to form a beam. The loading for each beam configura-


uniformly on two 3' (91.4 cm) and two
System

tion is shown in the beam loading tables on the next page.


4' (121.9 cm) beams which total 14'
Example - Load “A” (426.7 cm) of supporting beam length.
13⁄16"

Dividing the 1,000 lbs. (453.6 kg) load


Load “A” is supported by two 48"
by 14-feet equals 72 lbs. per foot (106.3
(121.9 cm) sections of PA-238 (15⁄8" x
kg per meter). Using the two 4' (121.9
23⁄8") (41.3mm x 60.3mm). The 48"
Fiberglass
System

cm) longest (weakest) lengths, calculate the total weight as


row in the PA 238 table on next page
follows:
indicates what each beam configura-
tion will support. Since the columns 2 (beams) x 4' (length) x 72 lbs./ft. = 576 lbs. total wt.
are sorted from lowest to highest load,
the first configuration that satisfies the requirement is “J” which
Special

2 (beams) x 121.9cm (length) x 106.3 kg/M = 25,915 kg total wt.


Metals

will support 1,100 lbs (499 kg).


Example - Load “B” The 36" (91.4 cm) row in the PA 238 table on next page
indicates what each beam configuration will support. Since the
Load “B” is supported by two 36"
PrimeAngle

columns are sorted from lowest to highest load, the first


System

(91.4 cm) sections of PA-238 (15⁄8" x configuration that satisfies the requirement is “J” which will
23⁄8") (41.3mm x 60.3mm). The 36" support 830 lbs. (376.5 kg) and is adequate for this requirement.
row in the PA 238 table on next page The 3-foot beams configured in the same manner will support
indicates what each beam configura- the load because they are shorter and stronger.
tion will support. Since the columns
Product
Index

are sorted from lowest to highest


load, the first configuration that satisfies the requirement is “J”
which will support 1,100 lbs (499 kg).

282 PrimeAngle
Prime Angle Beam Loads

Beam Loads (See corresponding letters in table on previous page for configurations)

Channel
15⁄8"
PA 158 Light Duty, (15⁄8" x 15⁄8" x 14 ga.)
Span G H I P L R M

Telestrut
In. (cm) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg)

System
24 550 830 830 920 1,600 1,700 1,840
61.0 249 376 376 417 726 771 835
36 370 560 560 610 1,070 1,130 1,230
91.4 168 254 254 277 485 513 558

Hardware
48 280 420 420 460 800 850 920

Nuts &
121.9 127 191 191 209 363 386 417
60 220 330 330 370 640 680 740
152.4 100 150 150 168 290 308 336
72 180 280 280 310 530 570 610
182.9 82 127 127 141 240 259 277

General
Fittings
84 • 240 240 260 460 490 530
213.4 109 109 118 209 222 240
96 • 210 210 230 400 430 460
243.8 95 95 104 181 195 209

Pipe/Conduit
108 • • • • 360 380 410

Supports
274.3 163 172 186
120 • • • • 320 340 370
304.8 145 154 168

PA 238 Medium Duty, (15⁄8" x 23⁄8" x 14 ga.)

Electrical
Fittings
Span G H I P J L R M K Q O N
In. (cm) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg)
24 700 1,020 1,660 1,740 2,220 3,170 3,230 3,490 3,590 3,630 6,060 7,560
61.0 318 463 753 789 1,007 1,438 1,465 1,583 1,628 1,647 2,749 3,429
36 460 680 1,100 1,160 1,480 2,110 2,150 2,320 2,390 2,420 4,040 5,040

Concrete
Inserts
91.4 209 308 499 526 671 957 975 1,052 1,084 1,098 1,833 2,286
48 350 510 830 870 1,110 1,580 1,620 1,740 1,800 1,810 3,030 3,780
121.9 159 231 376 395 503 717 735 789 816 821 1,374 1,715
60 280 410 660 700 890 1,270 1,290 1,390 1,440 1,450 2,420 3,020
152.4 127 186 299 318 404 576 585 630 653 658 1,098 1,370

11⁄4" Framing
72 230 340 550 580 740 1,060 1,080 1,160 1,200 1,210 2,020 2,520

System
182.9 104 154 249 263 336 481 490 526 544 549 916 1,143
84 • 290 470 500 630 910 920 1,000 1,030 1,040 1,730 2,160
213.4 132 213 227 286 413 417 454 467 472 785 980
96 • 260 410 440 550 790 810 870 900 910 1,520 1,890
243.8 118 186 200 249 358 367 395 408 413 689 857
108 • • • • 490 700 720 770 800 810 1,350 1,680

Framing
274.3 222 318 327 349 363 367 612 762

System
120 • • • • 440 630 650 700 720 730 1,210 1,510
304.8 200 286 295 318 327 331 549 685

13⁄16"
PA 318 Heavy Duty, (15⁄8" x 31⁄8" x 12 ga.)
Span G H I P J L R M K Q O N

Fiberglass
System
In. (cm) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg)
24 1,790 1,610 4,300 4,960 6,520 7,910 8,070 9,920 9,990 10,170 14,600 16,120
61.0 812 730 1,950 2,250 2,957 3,588 3,660 4,500 4,531 4,613 6,622 7,312
36 1,200 1,070 2,870 3,310 4,350 5,270 5,380 6,610 6,660 6,780 9,730 10,750
91.4 544 485 1,302 1,501 1,973 2,390 2,440 2,998 3,021 3,075 4,413 4,876
Special
Metals

48 900 810 2,150 2,480 3,260 3,950 4,030 4,960 4,990 5,080 7,300 8,060
121.9 408 367 975 1,125 1,479 1,792 1,828 2,250 2,263 2,304 3,311 3,656
60 720 640 1,720 1,980 2,610 3,160 3,230 3,970 4,000 4,070 5,840 6,450
152.4 327 290 780 898 1,184 1,433 1,465 1,801 1,814 1,846 2,649 2,926
72 600 540 1,430 1,650 2,170 2,640 2,690 3,310 3,330 3,390 4,870 5,370
PrimeAngle
System

182.9 272 245 649 748 984 1,197 1,220 1,501 1,510 1,538 2,209 2,436
84 • 460 1,230 1,420 1,860 2,260 2,300 2,830 2,850 2,910 4,170 4,610
213.4 209 558 644 844 1,025 1,043 1,284 1,293 1,320 1,891 2,091
96 • 400 1,080 1,240 1,630 1,980 2,020 2,480 2,500 2,540 3,650 4,030
243.8 181 490 562 739 898 916 1,125 1,134 1,152 1,656 1,828
108 • • • 1,100 1,450 1,760 1,790 2,200 2,220 2,260 3,240 3,580
Product
Index

274.3 499 658 798 812 998 1,007 1,025 1,470 1,624
120 • • • 990 1,300 1,580 1,610 1,980 2,000 2,030 2,920 3,220
304.8 449 590 717 730 898 907 921 1,324 1,461

PrimeAngle 283
® Prime Angle Column Loads

Column Loads
Channel

PA 158 (15⁄8" x 15⁄8" x 14 ga.)


15⁄8"

Column sections are calculated as


described in the following example: Span A B
(Assumes use of PA-238 15⁄8" x In. (cm) Lbs (kg) Lbs (kg)
Telestrut
System

23⁄8"(41.3mm x 60.3mm), material.) 36 1,450 3,850


91.4 658 1,746
Since all load areas are supported
48 1,150 3,500
equally by the 4-columns, the 121.9 522 1,588
calculations are based on a single- 60 950 3,000
Hardware

column section.
Nuts &

152.4 431 1,361


Section MN is one-fourth of “X”, or 72 750 2,500
250 pounds (113.4 kg). Column 182.9 340 1,134
section NP supports one-fourth of
PA 238 (15⁄8" x 23⁄8" x 14 ga.)
General
Fittings

“Y” (250 pounds) plus the load


supported by MN, or a total of 500
pounds (226.8 kg). Section PQ
supports one-fourth of “Z” (250
Pipe/Conduit

pounds) plus the 500 pound load on section NP, or a total of 750
Supports

(340.2 kg) pounds.


Span A B C D E F
Column loads are based on free and unbraced column lengths.
In. (cm) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg)
Since MN, NP and PQ are each 3' long, the load requirement is
for a 36" section that will bear 750 pounds safely. A reference to 36 2,280 4,760 4,940 7,270 9,520 9,865
91.4 1,034 2,159 2,241 3,298 4,318 4,475
the PA 238 table to the right indicates that all sections designated
Electrical

48 1,970 4,490 4,680 6,920 8,970 9,330


Fittings

“A” will support 2,280 lbs. (1,034.2 kg) and meet the necessary
121.9 894 2,037 2,123 3,139 4,069 4,232
requirements.
60 1,520 3,995 4,310 6,370 7,990 8,620
Note: To simplify assembly, we recommend using the same size 152.4 689 1,812 1,955 2,889 3,624 3,910
material as for the horizontal members. This would be found in 72 1,070 3,140 3,870 5,840 6,280 7,715
Concrete

Table 2 to match the 14 gauge 15⁄8" x 23⁄8" (41.3mm x 60.3mm) 182.9 485 1,424 1,755 2,649 2,849 3,499
Inserts

material selected for the beams of this structure. 84 660 2,340 3,665 4,930 4,660 6,740
213.4 299 1,061 1,662 2,236 2,114 3,057
A – Single Piece B – T-Section B – Broad 96 • 1,750 2,700 3,850 3,500 5,365
Channel Section 243.8 794 1,225 1,746 1,588 2,434
11⁄4" Framing

108 • • 2,060 2,870 • 4,115


System

274.3 934 1,302 1,867


120 • • 1,610 2,690 • 3,210
304.8 730 1,220 1,456

B – Narrow C – Uneven C – Uneven PA 318 (15⁄8" x 31⁄8" x 12 ga.)


Framing

Channel Section T-Section Channel Section


System
13⁄16"
Fiberglass

Span A B C D E F
System

In. (cm) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg) Lbs (kg)
D – Dual D – T-Channel D – T-Channel
36 3,470 7,970 8,770 12,560 15,940 17,550
Channel Section Section Section 91.4 1,574 3,615 3,978 5,697 7,230 7,961
48 2,870 7,360 8,580 11,970 14,750 17,150
Special
Metals

121.9 1,302 3,338 3,892 5,429 6,690 7,779


60 1,970 6,570 8,180 11,360 13,160 16,360
152.4 894 2,980 3,710 5,153 5,969 7,421
72 1,280 5,270 7,690 10,480 10,560 15,360
182.9 581 2,390 3,488 4,754 4,790 6,967
PrimeAngle
System

E – I-Section F – Uneven 84 • 3,670 6,970 9,470 7,370 13,970


I-Section 213.3 1,665 3,162 4,296 3,343 6,337
96 • 2,580 6,260 8,370 5,170 12,570
243.8 1,170 2,839 3,797 2,345 5,702
108 • • 5,460 6,880 • 10,970
Product

274.3 2,477 3,121 4,976


Index

120 • • 4,460 5,370 • 8,960


304.8 2,023 2,436 4,064

284 PrimeAngle
®
PRODUCT INDEX
200-3100 thru 200-3140 .............265 A2341 R-L ...................................222 F20P/V-1200 ...............................252
A1000 ..........................................206 A2345 ..........................................222 F20P/V-1300 ...............................252
A1000 EA .....................................277 A2472 R-L ...................................222 F20P/V-2000 ...............................250
A1001 ..........................................206 A2491 thru A2493 R-L ...............224 F20P/V-2000 ...............................251
A1001A thru A1001C ...................206 A2494 R-L thru A2497 R-L ........224 F20P/V-2000 SST ........................ 254
A1006 thru A1008 .......................215 A2608 thru A2617 .....................223 F20P/V-2000 SST ........................ 255
A1026 ..........................................218 A3006 thru A3008 ......................215 F20P/V-2000 thru F20P/V-2100 ..250
A1031 ..........................................218 A3016 thru A3016 ......................215 F20P/V-2000 thru F20P/V-2100 ..251
A1033 ..........................................219 A3300 ..........................................209 F20P/V-2100 ...............................250
A1036 ..........................................217 A3301 ..........................................209 F20P/V-2100 ...............................251
A1037 ..........................................219 A3345 ..........................................221 F20P/V-2100 SST ........................ 254
A1038 ..........................................219 A3347 ..........................................223 F20P/V-2100 SST ........................ 255
A1045 ..........................................220 A4000 ..........................................211 F20P/V-2200 ...............................250
A1047 ..........................................222 A4000 EA .....................................277 F20P/V-2200 SST ........................ 254
A1063 ..........................................217 A4001 ..........................................211 F20P/V-2300 ...............................250
A1065 ..........................................217 A4001 EA .....................................277 F20P/V-2300 SST ........................ 254
A1066 ..........................................217 A4006 thru A4008 ......................215 F20P-2500 thru F20V-2500 ......... 260
A1068 ..........................................218 A4045 ..........................................221 F20P-2502 thru F20V-2502 ......... 260
A1184 ..........................................216 A4047 ..........................................223 F20P-2504 thru F20V-2504 ......... 260
A1184P ........................................216 A4120 ..........................................220 F20P-2506 thru F20V-2506 ......... 260
A1191 ..........................................217 A4280 ..........................................216 F20P-2508 thru F20V-2508 ......... 261
A1280 ..........................................216 A5000 ..........................................213 F20P-2510 thru F20V-2510 ......... 261
A1325 ..........................................218 A5006 thru A5008 .......................215 F20P-2512 thru F20V-2512 ......... 261
A1326 ..........................................218 A5043 ..........................................223 F20P-2514 thru F20V-2514 ......... 261
A1331 ..........................................219 A5045 ..........................................221 F20P-2516 thru F20V-2516 ......... 261
A1332 ..........................................219 A5047 ..........................................223 F20P-2518 thru F20V-2518 ......... 261
A1357 ..........................................219 A5120 ..........................................220 F20P-2520 thru F20V-2520 ......... 262
A1458 ..........................................218 A5280 ..........................................216 F20P-2522 thru F20V-2522 ......... 262
A1579 ..........................................220 CG-10 thru CG-40 ......................157 F20P-2524 thru F20V-2524 ......... 262
A2084 ..........................................221 F20E-5000 ...................................259 F20P-2526 thru F20V-2526 ......... 262
A2109 thru A2111 ......................221 F20N-ARM08 thru F20N-STA33 ..268 F20P-2528 thru F20V-2528 ......... 262
A2120 ..........................................220 F20P/V-1000 ...............................252 F20P-2530 thru F20V-2530 ......... 262
A2125 thru A2127 ......................221 F20P/V-1000 ...............................253 F20P-2534 thru F20V-2534 ......... 263
A2223 ..........................................222 F20P/V-1000 thru F20P/V-1100 ..252 F20P-2540 thru F20V-2540 ......... 263
A2227 ..........................................222 F20P/V-1000 thru F20P/V-1100 ..253 F20PU-5853 thru F20PU-5855 ....264
A2235 ..........................................220 F20P/V-1100 ...............................252 F20PU-5903 thru F20PU-5905 ....264
A2324 ..........................................217 F20P/V-1100 ...............................253 F50PU-1508 thru F50PU-2008 ....263

285
® Part Number Index

F50PU-2045 ................................264 LS 500 .........................................144 P1029 ............................................97


Channel

F50PU-2090 ................................264 M24 ............................................. 199 P1031 ............................................92


15⁄8"

F50PU-2538 ................................263 M2037 thru M2050 ..................... 184 P1033 ............................................97


F50PU-2611 ................................263 M2137 thru M2150 ..................... 184 P1034 ............................................97
Telestrut
System

F50PU-2613 ................................263 M2250 ......................................... 184 P1035 ............................................97


F50PU-2616 ................................264 M2350 ......................................... 184 P1036 ............................................92
F50PU-2636 ................................264 M5025 thru M5060 ...................151 P1037 ............................................97
Hardware
Nuts &

F50PU-500SP .............................. 258 P16F ............................................185 P1038 ............................................97


F100-1500 thru F100-1512 ......... 267 P21H ...........................................185 P1043A ........................................108
F200-3827 thru F200-3831 ......... 258 P1000 ............................................25 P1044 .......................................... 108
General
Fittings

F200-3840 thru F200-3843 ......... 258 P1000 DS ......................................25 P1045 .......................................... 102
F200-4101 ...................................267 P1000 EA .....................................276 P1046A ........................................109
F200-4226 thru F200-4343 ......... 256 P1000 H3 ......................................25 P1047 .......................................... 106
Pipe/Conduit
Supports

F250E thru F1000E ......................258 P1000 HS ......................................25 P1048 thru P1050 .......................107
F250PU thru F625PU ...................257 P1000 KO ......................................25 P1062 thru P1064 .........................90
F250PU-075 thru F500PU-350 ....257 P1000 Series ...............................273 P1065 ............................................90
F250PU-CN thru F10PU-CNS .......256 P1000 SL .......................................25 P1066 ............................................91
Electrical
Fittings

F375PU & F500PU .......................268 P1000 SS .................................... 273 P1067 ............................................91


F375PU-125 thru F625PU-350 ....257 P1000 T .........................................25 P1068 ............................................94
F375PU-CNHD thru P1000HS SS ................................273 P1075 .......................................... 116
Concrete
Inserts

F20PU-CNMHD ....................256 P1000T SS ..................................273 P1100 ............................................32


F375PU-FN thru F750PU-FN ........257 P1001 ............................................25 P1100 HS ......................................32
FAIC-EC ....................................... 259 P1001 3 .........................................29 P1100 KO ......................................32
11⁄4" Framing

FCVHPU-100 thru FCVHPU-600 ..267 P1001 A .........................................28 P1100 Series ...............................273


System

FPCR-050 thru FPCR-800 ............ 266 P1001 A3 .......................................29 P1100 SL .......................................32


FPS200 thru FPS1800 .................266 P1001 B .........................................28 P1100 SS .................................... 273
FRGBC .........................................268 P1001 B3 .......................................29 P1100 T .........................................32
Framing

FUB-050 thru FUB-600 ................259 P1001 C .........................................28 P1100HS SS ................................273


System

HCSS .............................................81 P1001 C3 .......................................29 P1100T SS ..................................273


13⁄16"

HFLW .............................................82 P1001 C41 .....................................29 P1101 ............................................32


HFMS .............................................81 P1001 D3 ......................................29 P1101 A .........................................33
Fiberglass

HHCS .............................................81 P1001 EA .....................................276 P1101 B .........................................33


System

HHXN .............................................82 P1001 SS .................................... 273 P1101 C .........................................33


HLKW ............................................82 P1001 T .........................................28 P1101 SS .................................... 273
HOCW ............................................84 P1003 ............................................29 P1109 thru P1126 .......................147
Special
Metals

HRCN .............................................84 P1004 A .........................................29 P1130 thru P1131 .......................100


HRMS ............................................81 P1006 thru P1010 .........................78 P1180 ............................................60
HSHS .............................................81 P1006T thru P1010T .....................79 P1180 thru P5580 .........................60
PrimeAngle
System

HSQN .............................................82 P1012 thru P1024 .........................79 P1180W thru P5580 ....................180
HTHR .............................................83 P1012S thru P1024S .....................78 P1184 ............................................59
J1205 thru J1280 ........................ 158 P1026 ............................................94 P1184 P .........................................59
Product

LS 410 .........................................144 P1028 ............................................93 P1184 SS .................................... 274


Index

286 Product Index


Part Number Index

P1186 .......................................... 101 P1498 thru P1499 .........................95 P1944 .......................................... 139

Channel
P1201 thru P1203 .......................138 P1538A thru P1538D ..................... 95 P1950 ............................................93

15⁄8"
P1204 thru P1208 .......................139 P1546 .......................................... 101 P1953 ............................................93
P1211 thru P1217 .......................149 P1563 thru P1573 ..................... 149 P1956 .......................................... 100

Telestrut
System
P1271S ........................................128 P1579 ............................................99 P1957 .......................................... 100
P1272S ........................................133 P1593 .......................................... 116 P1959 thru P1961 .........................90
P1280 ............................................60 P1648S thru P1653S .................127 P1962 ............................................94

Hardware
Nuts &
P1280 A thru P2280 A ...................60 P1654A thru P1661A .................128 P1964 ............................................90
P1280 EA .....................................278 P1690 thru P1697 .......................174 P1973 .......................................... 108
P1281 thru P1283 .........................94 P1703 thru P1704 .......................201 P1985S thru P1986S ...................133

General
Fittings
P1290 ............................................98 P1713 ............................................99 P2000 ............................................36
P1291 ............................................98 P1723 ............................................94 P2000 HS ......................................36
P1315 ............................................95 P1726 ............................................93 P2000 KO ......................................36

Pipe/Conduit
Supports
P1320 .......................................... 105 P1727 ............................................99 P2000 SL .......................................36
P1325 ............................................96 P1728 ............................................99 P2000 T .........................................36
P1326 ............................................96 P1730 .......................................... 103 P2001 ............................................36
P1334 ............................................92 P1732 .......................................... 107 P2001 A .........................................37

Electrical
Fittings
P1346 ............................................96 P1734 .......................................... 103 P2001 B .........................................37
P1347 .......................................... 102 P1736 .......................................... 103 P2001 C .........................................37
P1354 .......................................... 138 P1737 .......................................... 108 P2008 thru P2020 ..................... 149

Concrete
Inserts
P1354A ........................................138 P1747 ............................................95 P2024 thru P2070-84 ................148
P1356 ............................................93 P1750 ............................................95 P2072 thru P2072 SQ .................. 113
P1357 ............................................98 P1753 thru P1754 .......................173 P2072A thru P2072A SQ .............113

11⁄4" Framing
P1358 ............................................93 P1769 .......................................... 115 P2073 .......................................... 114

System
P1359 ............................................98 P1771 .......................................... 115 P2073A ........................................114
P1363A thru P1363E .................105 P1773 .......................................... 115 P2079 ............................................91
P1376 .......................................... 105 P1775 .......................................... 115 P2094 thru P2100 ..................... 101

Framing
P1376A ........................................105 P1777 .......................................... 116 P2101 thru P2104 ..................... 101

System
P1377 .......................................... 106 P1787 thru P1795 .......................175 P2105 thru P2110 ..................... 101

13⁄16"
P1379S ........................................132 P1796S ........................................ 128 P2223 .......................................... 110
P1380 ............................................92 P1821 ............................................96 P2224 .......................................... 110

Fiberglass
P1380 A .........................................92 P1822 ............................................96 P2225 .......................................... 110

System
P1381 ............................................98 P1823 ............................................96 P2226 .......................................... 111
P1382 ............................................98 P1834 .......................................... 137 P2227 .......................................... 110
P1383 .......................................... 107 P1834A ........................................ 137 P2228 .......................................... 110
Special
Metals

P1386 .......................................... 132 P1843 .......................................... 138 P2229 .......................................... 111


P1425 thru P1431 ..................... 147 P1873 ............................................92 P2230 .......................................... 112
P1453 .......................................... 102 P1887 .......................................... 112 P2231 thru P2232 .......................119
PrimeAngle
System

P1454 .......................................... 102 P1924 ............................................90 P2231A thru P2232A ...................120


P1455 .......................................... 106 P1925 ............................................91 P2233 thru P2234 .......................119
P1458 ............................................95 P1934 ............................................99 P2233A thru P2234A ...................120
Product

P1479A thru P1479E .................103 P1941 ............................................91 P2235 ............................................99


Index

Product Index 287


® Part Number Index

P2237 .......................................... 107 P2490 ............................................90 P2785 .......................................... 129


Channel

P2243 .......................................... 162 P2491 R-L thru P2493 R-L ........117 P2786 .......................................... 129
15⁄8"

P2245 .......................................... 112 P2494 R-L thru P2499 R-L ........117 P2787 .......................................... 129
P2260 thru P2270 .......................102 P2500 R-L thru P2503 R-L ........117 P2800 .......................................... 104
Telestrut
System

P2280 ............................................60 P2513 thru P2516 .......................119 P2801 .......................................... 182


P2324 ............................................91 P2513A thru P2516A ................... 120 P2802 .......................................... 182
P2325 ............................................90 P2521-100 ...................................180 P2803 .......................................... 182
Hardware
Nuts &

P2326 .......................................... 109 P2521-50 thru P2521-75 ............. 179 P2815 .......................................... 122
P2328 .......................................... 109 P2522 .......................................... 179 P2815D ....................................... 122
P2329 .......................................... 109 P2534 .......................................... 178 P2820 .......................................... 187
General
Fittings

P2341 R-L ...................................109 P2535 .......................................... 179 P2821 .......................................... 187


P2343 R-L ...................................110 P2536 .......................................... 179 P2822 .......................................... 187
P2344 R-L ...................................111 P2537 .......................................... 177 P2823 .......................................... 187
Pipe/Conduit
Supports

P2345 .......................................... 111 P2539 .......................................... 177 P2824 .......................................... 129


P2346 .......................................... 111 P2540 thru P2540A ..................... 181 P2855 thru P2857 .......................177
P2347 .......................................... 111 P2541 .......................................... 180 P2859 ............................................60
P2348 .......................................... 112 P2542 thru P2546 .......................118 P2860 ............................................60
Electrical
Fittings

P2354 thru P2355 R-L ................138 P2547 thru P2551 .......................118 P2862 thru 2864 ...........................90
P2360 .......................................... 103 P2552 .......................................... 181 P2865 .......................................... 197
P2378-P2382 ................................80 P2557 .......................................... 176 P2867 .......................................... 130
Concrete
Inserts

P2398S thru P2403S ...................127 P2558-5 thru P2558-60 ............. 150 P2867A ........................................130
P2407 .......................................... 201 P2567 .......................................... 176 P2867B ........................................130
P2426 thru P2431 ..................... 150 P2600 .......................................... 152 P2868 .......................................... 130
11⁄4" Framing

P2452 .......................................... 121 P2602 .......................................... 182 P2868A ........................................131


System

P2453 .......................................... 112 P2603 .......................................... 181 P2868B ........................................131


P2454 .......................................... 139 P2609 thru P2617 ..................... 150 P2893 .......................................... 131
P2458-18 thru P2458-36 ...........121 P2626 ............................................94 P2894 .......................................... 131
Framing

P2459-36 thru P2459-96 ...........122 P2645A thru P2645H ................ 173 P2895 .......................................... 132
System

P2469 .......................................... 104 P2647A thru P2647F .................174 P2896 .......................................... 132
13⁄16"

P2470 .......................................... 139 P2649A thru P2649H ................... 173 P2897 .......................................... 123
P2471 ............................................90 P2655 .......................................... 139 P2898 .......................................... 125
P2472 R-L ...................................109 P2674 .......................................... 126 P2899 .......................................... 125
Fiberglass
System

P2473 .......................................... 108 P2675 .......................................... 124 P2900 .......................................... 183


P2474 .......................................... 159 P2676 .......................................... 124 P2901 .......................................... 183
P2474-1 thru P2474-4 ............... 160 P2677 .......................................... 126 P2902 .......................................... 183
Special
Metals

P2475 .......................................... 161 P2679 .......................................... 126 P2903 .......................................... 183


P2476 .......................................... 161 P2682 .......................................... 126 P2904 .......................................... 183
P2481 .......................................... 162 P2749 thru P2749N ..................... 136 P2920 thru P2924 ..................... 188
PrimeAngle
System

P2482 .......................................... 162 P2750 thru P2750N ..................... 136 P2928 thru P2930 .......................188
P2484 .......................................... 100 P2751 thru P2751 N ....................136 P2932 .......................................... 187
P2484W ....................................... 100 P2755 thru P2757 .......................177 P2940 .......................................... 187
P2485 ............................................84 P2784 .......................................... 123 P2941 thru P2942 .......................113
Product
Index

288 Product Index


Part Number Index

P2944 thru P2947 .......................118 P3380 ..........................................201 P5000 HS ......................................53

Channel
P2949 .......................................... 137 P3409 thru P3417 .....................151 P5000 KO ......................................53

15⁄8"
P2950 .......................................... 137 P3521-50 .....................................179 P5000 SL .......................................53
P3000 ............................................40 P3539 ..........................................177 P5000 T .........................................53

Telestrut
System
P3000 SS ...................................273 P3663 ..........................................201 P5001 ............................................53
P3000 HS ......................................40 P3700 Series ...............................200 P5021-100 ...................................180
P3000 KO ......................................40 P3703 thru P3704 .......................201 P5021-50 thru P5021-75 .............180

Hardware
Nuts &
P3000 Series ...............................273 P3712 P .........................................59 P5077 .......................................... 106
P3000 SL .......................................40 P3754 Series ...............................195 P5280 ............................................60
P3000 T .........................................40 P3922 thru P3926 .......................178 P5500 ............................................56

General
Fittings
P3000HS SS ................................273 P4000 ............................................46 P5500 EA .....................................276
P3000T SS ..................................273 P4000 SS ...................................274 P5500 HS ......................................56
P3001 ............................................40 P4000 EA .....................................276 P5500 KO ......................................56

Pipe/Conduit
Supports
P3001 T .........................................40 P4000 HS ......................................46 P5500 SL .......................................56
P3006 thru P3013 .........................79 P4000 SL ....................................... 46 P5500 T .........................................56
P3016-0632 thru P3016-1420 .......79 P4000 T .........................................46 P5501 ............................................56
P3045 .......................................... 104 P4000HS SS ................................274 P5501 T .........................................56

Electrical
Fittings
P3047 .......................................... 106 P4000T SS ..................................274 P5506 thru P5510 .........................78
P3087 .......................................... 133 P4001 ............................................46 P5521-100 ...................................180
P3088 .......................................... 133 P4001 EA .....................................276 P5521-50 thru P5521-75 .............179

Concrete
Inserts
P3116-125 ...................................181 P4003 ............................................47 P5537 .......................................... 177
P3165 Series ...............................197 P4004 ............................................47 P5539 .......................................... 177
P3184 ............................................59 P4006 thru P4010 ......................... 78 P5543 .......................................... 107

11⁄4" Framing
P3184 EA .....................................278 P4012 thru P4023 ......................... 79 P5545 .......................................... 104

System
P3184 F .........................................59 P4012S thru P4023S ..................... 78 P5547 .......................................... 107
P3184 P .........................................59 P4043 ..........................................108 P5560 .......................................... 103
P3200 Series ...............................196 P4045 ..........................................104 P5577 .......................................... 106

Framing
P3245 .......................................... 199 P4047 ..........................................106 P5580 ............................................60

System
P3280 .......................................... 201 P4100 ............................................50 P5580 EA .....................................278

13⁄16"
P3300 ............................................43 P4100 HS ......................................50 P6000 .......................................... 228
P3300 HS ......................................43 P4100 SL ....................................... 50 P6000 EA .....................................277
P3300 Series ...............................198 P4100 T .........................................50 P6000 SS .................................... 274

Fiberglass
System
P3300 Series ...............................273 P4101 ............................................50 P6001 .......................................... 228
P3300 SL .......................................43 P4101 T .........................................50 P6001 EA .....................................277
P3300 SS .................................... 273 P4280 ............................................60 P6001A ........................................228
Special
Metals

P3300 T .........................................43 P4280 EA .....................................278 P6001B ........................................228


P3300HS SS ................................273 P4376 ..........................................105 P6001C ........................................228
P3300T SS ..................................273 P4376A ........................................105 P6006-0832 thru P6006-1420 .....233
PrimeAngle
System

P3301 ............................................43 P4377 ..........................................106 P6026 .......................................... 237


P3301 SS .................................... 273 P4663 ..........................................201 P6028 .......................................... 236
P3301 T .........................................43 P4908 ............................................79 P6031 .......................................... 236
P3345 .......................................... 104 P5000 ............................................53 P6033 .......................................... 238
Product
Index

Product Index 289


® Part Number Index

P6036 .......................................... 236 P6386 .......................................... 246 P9010 ............................................82


Channel

P6037 .......................................... 238 P6453 .......................................... 242 P9011 ............................................72


15⁄8"

P6038 .......................................... 238 P6454 .......................................... 242 P9012 ............................................72


P6044 .......................................... 245 P6455 .......................................... 245 P9013 ............................................72
Telestrut
System

P6045 .......................................... 242 P6458 .......................................... 238 P9014 ............................................72


P6047 .......................................... 243 P6546 .......................................... 241 P9200 ............................................67
P6048 .......................................... 243 P6579 .......................................... 239 P9207 ............................................71
Hardware
Nuts &

P6062 .......................................... 234 P6726A ........................................235 P9209 ............................................70


P6065 .......................................... 234 P6728 .......................................... 239 P9209 ............................................82
P6066 .......................................... 235 P6737 .......................................... 243 P9324 ............................................71
General
Fittings

P6067 .......................................... 235 P6758 .......................................... 243 PA 158 .........................................280


P6068 .......................................... 237 P6805 thru P6810 ..................... 246 PA 1GP ........................................281
P6069 .......................................... 237 P6887 .......................................... 240 PA 1HDC ......................................281
Pipe/Conduit
Supports

P6127 thru P6129 .......................245 P6917 .......................................... 239 PA 1RC ........................................281


P6130 .......................................... 240 P6918 .......................................... 239 PA 1RP ........................................281
P6184 P ....................................... 233 P6924 .......................................... 234 PA 1SC ........................................281
P6186 .......................................... 241 P6925 .......................................... 234 PA 1SNB ......................................281
Electrical
Fittings

P6280 .......................................... 233 P6962 .......................................... 235 PA 238 .........................................280


P6281 thru P6283 .......................237 P6973 .......................................... 245 PA 318 .........................................280
P6290 .......................................... 240 P7000 .......................................... 231 PFL037 thru PFL050T .................. 134
Concrete
Inserts

P6291 .......................................... 240 P7000 EA .....................................278 PFL2-37 ....................................... 123


P6325 .......................................... 238 P7000 SS .................................... 274 PLF3037 thru PLF3075 ..............135
P6326 .......................................... 237 P7001 .......................................... 231 PLF9037 thru PLF9100 ..............135
11⁄4" Framing

P6331 .......................................... 241 P7001 EA .....................................278 PLLC025 ......................................134


System

P6332 .......................................... 241 P7006-0832 thru P7006-1420 .....233 PUX3834 thru PUX41810 ............ 157
P6334 .......................................... 236 P7008 thru P7020 ..................... 246 SPF 100 ....................................... 140
P6346 .......................................... 237 P7045 .......................................... 242 SPF 200 ....................................... 141
Framing

P6347 .......................................... 242 P7047 .......................................... 243 SPF 300 ....................................... 142
System

P6349 .......................................... 245 P7048 .......................................... 243 SPF 400 ....................................... 143
13⁄16"

P6353 .......................................... 245 P7097 thru P7101 .......................241 UB1/2PA thru UB12PA ..............156
P6356A ........................................ 235 P7108 thru P7110 .......................241 UP-BK thru UP-MPDS ................163
Fiberglass

P6357 .......................................... 238 P7235 .......................................... 239 004M007 thru 034M040 ...........155
System

P6358A ........................................ 235 P7280 .......................................... 233 004T008 thru 098N106 ............... 154
P6359 .......................................... 239 P7324 .......................................... 234 009N012 thru 106N114 ............... 154
P6376 .......................................... 244 P7325 .......................................... 234
Special
Metals

P6376A ........................................ 244 P7347 .......................................... 242


P6377 .......................................... 244 P7376 .......................................... 244
P6379 S ....................................... 246 P7376A ........................................244
PrimeAngle
System

P6380 .......................................... 236 P7377 .......................................... 244


P6380A ........................................ 236 P7758 .......................................... 243
P6381 .......................................... 240 P9000 ............................................67
Product

P6382 .......................................... 240 P9010 ............................................70


Index

290 Product Index


The Unistrut®
Metal Framing System
…engineered solutions you can count on!

Products of UNISTRUT are manufactured un-


der one or more of the following United States
patents:
3,362,738 3,388,809 3,415,554
3,417,951 3,421,280 3,437,779
3,443,348 3,468,567 3,601,347
Meet Mr. Strut 3,617,076 3,618,882 3,628,296
Mr. Strut has symbolized Unistrut 3,721,463 3,861,107 3,877,275
innovation for over 50 years and 3,888,440 3,888,441 3,914,063
he’s still coming up with fresh 3,927,499 3,928,930 3,948,012
ideas and new ways to help you 3,968,624 3,994,111 4,073,114
work easier, faster and smarter! 4,277,923 4,278,288 4,289,415
So watch for Mr. Strut. When
Foreign patents and other patents pending
he’s around you’re never
far from the Unistrut
World of Support. The product Application SHOWCASE
Allows you to build a strong reputation with
a World of Support from Unistrut. It’s packed
with examples and application photos of the
Unistrut Framing System in action. Call for
your copy today.

Registered Trademarks of UNISTRUT:


“AXENT”, “UNISTRUT”, “P1000”, Marketing throughout the world by Unistrut:
“TELESPAR”, “TELESTRUT”, “UNI-CLIP”, Tel: (800) 521-7730 • www.unistrut.com
“UNICUSHION”, “UNIROD”, “GRAB BAG”,
“Prime Angle” and the cartoon character
“Mr. Strut”.
“SPF” is a Registered Trademarks of
Lord & Sons.
“Cush-A-Grip” is a Registered Trademarks of
ZSi.

When there’s work to be done,


build with the leader…
Unistrut®
General Engineering Catalog
Unistrut UNISTRUT CANADA
4205 Elizabeth 585 Finley Avenue
Wayne, MI 48184 Ajax, Ontario, L1S-2E4 Canada
Phone: 800-521-7730 Tel: (800) 267-4959 (Canada only)
Fax: 734-721-4106 Tel: (905) 683-8131
www.unistrut.com Fax: (905) 683-8987

#15
© Unistrut Corporation • U-15 • Printed in USA • 9/06

You might also like