Intercomparison and Validation of Computer Codes For Thermalhydraulic Safety Analysis of Heavy Water Reactors
Intercomparison and Validation of Computer Codes For Thermalhydraulic Safety Analysis of Heavy Water Reactors
Intercomparison and
Validation of computer codes for
thermalhydraulic safety analysis
of heavy water reactors
August 2004
IAEA-TECDOC-1395
Intercomparison and
Validation of computer codes for
thermalhydraulic safety analysis
of heavy water reactors
August 2004
The originating Section of this publication in the IAEA was:
Nuclear Power Technology Development Section
International Atomic Energy Agency
Wagramer Strasse 5
P.O. Box 100
A-1400 Vienna, Austria
Activities within the frame of the IAEA’s Technical Working Group on Advanced
Technologies for HWRs (TWG-HWR) are conducted in a project within the IAEA’s
subprogramme on nuclear power reactor technology development. The objective of the
activities on HWRs is to foster, within the frame of the TWG-HWR, information exchange
and co-operative research on technology development for current and future HWRs, with an
emphasis on safety, economics and fuel resource sustainability.
One of the activities recommended by the TWG-HWR was an international standard problem
exercise entitled: “Intercomparison and validation of computer codes for thermalhydraulics
safety analyses”. Intercomparison and validation of computer codes used in different
countries for thermalhydraulics safety analyses will enhance the confidence in the predictions
made by these codes. However, the intercomparison and validation exercise needs a set of
reliable experimental data. The RD-14M Large-Loss Of Coolant Accident (LOCA) test
B9401 simulating HWR LOCA behaviour that was conducted by Atomic Energy of Canada
Ltd (AECL) was selected for this validation project. This report provides a comparison of the
results obtained from six participating countries, utilizing four different computer codes.
General conclusions are reached and recommendations made.
The IAEA expresses its appreciation to the CANDU Owners Group (COG) for releasing the
experimental data to the international community, and to D. Richards of AECL, Canada for
leading the activity. The IAEA officer responsible for this publication was R. Lyon of the
Division of Nuclear Power.
EDITORIAL NOTE
The use of particular designations of countries or territories does not imply any judgement by the
publisher, the IAEA, as to the legal status of such countries or territories, of their authorities and
institutions or of the delimitation of their boundaries.
The mention of names of specific companies or products (whether or not indicated as registered) does
not imply any intention to infringe proprietary rights, nor should it be construed as an endorsement
or recommendation on the part of the IAEA.
CONTENTS
CHAPTER 1. INTRODUCTION............................................................................................... 1
REFERENCES....................................................................................................................... 117
£
CANDU is a registered trademark of Atomic Energy of Canada Limited
1
CHAPTER 2. RD-14M EXPERIMENT LOOP
The RD-14M facility, shown schematically in Figure 2.1, is a pressurised-water loop with
essential features similar to the primary heat transport loop of a typical CANDU reactor. The
facility is designed so that reactor typical conditions, such as fluid mass flux, transit time,
pressure and enthalpy, can be achieved in the primary-side for both forced and natural
circulation. The design incorporates the basic "figure-of-eight" geometry of a CANDU
reactor, with five horizontal channels per pass and a 1:1 scaling of the vertical elevations
throughout the loop. Each six-meter-long channel contains 7 electrically heated Fuel Element
Simulators (FES), connected to end-fitting simulators. The feeder volumes, areas, and metal
masses are appropriately scaled to the channels (7-pin FES). The thermal characteristics of the
FES are similar to CANDU fuel in terms of power density, heat flux and heat capacity. The
channel inlet and outlet-feeder piping arrangements are designed to represent Darlington
Nuclear Generating Station (NGS) feeders.
Five reactor channel/feeder geometries were selected, representing three middle channels, one
top channel, and one bottom channel. Preserving the 1:1 vertical scaling maintained similar
hydrostatic pressures between RD-14M and a typical reactor. The inlet feeders are 1 –1.25"
nominal schedule 40, while the outlet feeders are 1.25 –.50" nominal schedule 40. The above
header piping is sized to give reactor-typical pressure drops.
A test section in RD-14M consists of an electrically heated section (fuel element simulators),
inlet and outlet end-fitting simulators, a pressure tube, and a strongback to provide support for
the test section.
The heated section is a 6-m long channel between the inlet and outlet end-fitting simulators,
composed of a flow tube containing a 7-pin FES. Figure 2.2 is a cross-section of a typical RD-
14M heated section. The FES pins are divided into 12 axial segments, each having a length of
495 mm and separated by short unheated sections to simulate fuel bundle spacers. The FES
pins consist of a central core of magnesium oxide surrounded by an electrically heated Inconel
625 tube of 7.62 mm outside diameter. The tube is insulated from the 13.18 mm outside
diameter stainless steel (type-304) sheath by a 2 mm thick annulus of boron nitride. The FES
pins are surrounded by a 44.80 mm inside diameter, 57.20 mm outside diameter 316-type
stainless steel flow tube that is surrounded by vermiculite insulation.
The RD-14M end-fitting simulators consist of a shield plug and liner tube contained within a
flow tube. The RD-14M shield plug and liner tube annulus are sized to the reactor flow
annulus using a 7:37 ratio. The end-fitting simulators are designed to reproduce the
differential pressure and the thermal mass of typical reactor end-fittings.
The steam generators are scaled approximately 1:1 with typical CANDU steam generators, in
terms of tube diameter, mass flux, and heat flux. The steam generators are 12 m in height and
originally contained 44 U-tubes that have an outside diameter of 15.88 mm and a wall
thickness of 1.13 mm. Over time, some U-tubes have developed leaks around the penetrations
of instruments. These tubes have been plugged and are indicated in the electronic database.
The secondary-sides of the steam generators contain an internal preheater and an external
downcomer. Spiral-arm steam separators in the steam dome and flow restricting orifices in the
external downcomer of the steam generators are used to produce reactor-typical recirculation
3
in the secondary-side. Sizing is based on the consideration of removing up to 5.5 MW from
each of the steam generators.
Primary fluid circulation is provided by two centrifugal pumps. These deliver full reactor-
typical head (about 225 m) at flowrates similar to a single reactor channel (about 24 kg/s).
Primary circuit pressure is maintained by a loop pressuriser that contains an electrical heater.
Both inlet and outlet header breaks can be produced using the blowdown system. Replacing
the end cap of the relevant header with a fast-acting ball valve simulates a break. A range of
break sizes can be investigated by placing appropriately sized orifice plates immediately
upstream of the fast-acting 6" ball valve leading to the blowdown stack. The coolant is
discharged through the ball valve and into the blowdown stack (20" nominal pipe) that passes
through the roof of the test facility.
The RD-14M facility is equipped with an Emergency Core Coolant (ECC) system that
provides cooling to the FES under postulated LOCA conditions. The ECC system injects
emergency coolant into the primary heat transport system through any combination of the four
headers. The ECC system is controlled by the primary loop pressure at header 7 with the
isolation valves automatically opening when header 7 pressure drops below a predetermined
pressure.
Major loop parameters of the RD-14M facility are compared with a typical CANDU reactor in
Table 2.1. More detailed information on the RD-14M facility can be found in [1].
2.2. Instrumentation
The RD-14M facility is extensively instrumented for data gathering during experiments. The
data acquisition system consists of several input multiplexers each connected to an analog-to-
digital converter, and a VAX 4000 Model 200 computer using a VMS 5.5-2 operating system
capable of scanning up to 768 channels at a maximum rate of about 50 ms per scan (20 Hz).
Data for RD-14M test B9401 was sampled every 100 ms (10 Hz). Parameters measured
included fluid and FES temperatures, gauge and differential pressures, levels, flows, void
fractions, power, and pump speeds. Over 400 temperatures at various locations around the
primary and secondary loops were measured. Fluid and FES temperatures were measured
using K-type thermocouples and resistance temperature detectors (RTDs). Gauge and
differential pressures and levels were measured using Rosemount pressure transducers.
Flowrates at the inlet and outlet of each test section, at the pump discharge, and the feedwater
to each boiler were measured using turbine flow meters. The void fraction at the inlet and
outlet of each boiler, at the pump discharge, and at the inlet and outlet of each test section was
measured using three-beam, two-beam, and single-beam gamma densitometers, respectively.
It should be noted that the void fraction at the inlet and outlet of each test section is measured
approximately 2-m upstream and downstream of each test section. The locations of the
gamma densitometers and turbine flow meters, in relation to test section 11, are shown in
Figure 2.3 as an example. Table 2.2 lists the measurement uncertainties. More detailed
information on the RD-14M instrumentation and control of the RD-14M facility can be found
in [1].
4
Table 2.1. Comparison of RD-14M Loop Characteristics with a Typical CANDU Reactor
CHARACTERISTIC RD-14M Typical CANDU Reactor
Operating Pressure (MPa) 10 10
3 1.01 60
Loop Volume (m )
Heated Sections/Fuel Channels 1 indirectly heated 7-rod Nuclear fuel 37-rod bundle
bundle
Number of Channels Per Pass 5 95
Length (m) 6 12 x 0.5
Fuel Rod Diameter (mm) 13.1 13.1
Flow Tube ID (mm) 44.8 103.4
Power (kW/channel) 3x750 and 2x950 5410*
Pumps: Single Stage Single Stage
Impeller Diameter (mm) 381 813
Rated Flow (kg/s) 24 24*
Rated Head (m) 224 215
Rated Speed (rpm) 3560 1790
Specific Speed 565 2000
Steam Generators: Recirculating U-tube Recirculating U-tube
Tube Bundle Height (m) 9.42 9.42
Number of Tubes 44 37*
Tube ID (mm) 13.6 14.75
Tube OD (mm) 15.9 15.9
2 41 32.9*
Secondary Heat Transfer Area (m )
3 0.9 0.131*
Secondary Volume (m )
Recirculation Ratio at Full Power 6:1 5.7:1
2 130 165
Heat Flux (kW/m )
5
Table 2.2. Experimental Measurement Uncertainties
6
Fig. 2.1. Schematic of the RD-14M Facility.
7
304-SS Sheath Inconel 625
13.18 mm O.D. Boron Nitride 7.62 mm O.D.
Annulus Heater Tube
MgO Core
Typical Sheath
Thermocouple
Typical Core
Thermocouple
8
Fig. 2.3. Location of Instrumentation at the Inlet and Outlet of Test Section 11.
9
CHAPTER 3. RD-14M TEST B9401
RD-14M test B9401 was a 30-mm diameter inlet-header break test with a high pressure
pumped emergency coolant injection available. The test was conducted in 1994. The purpose
of the test was to investigate the primary loop response to a 30-mm break with emergency
coolant injection.
The nominal initial conditions for the test B9401 were as follows:
Temperature 30°C
The loop was operated until the required single-phase, steady state conditions were achieved
and then scanning of the experimental data was started. The blowdown valve was opened at
inlet header 8 to simulate the break approximately 10 s after data sampling started. About two
seconds after break initiation, the power (Table 3.1) was decreased to represent decay power
levels and the primary loop pump speeds were exponentially decreased to simulate the loss of
class IV power. The ECC isolation valves were opened at 20.6 s and the Pressurizer was
manually isolated at 22.8 s. The test was terminated after an extended period at decay power
levels. A summary of the significant events in test B9401 is shown in Table 3.2.
Five hundred fifty-eight (558) channels of data were scanned and collected during test B9401.
Detailed test information can be found in Appendix B of [1], and the electronic version of the
data was provided on CD-ROM. A subset of the measured variables was used for the inter-
comparison activity.
11
Table 3.1. Input Power for B9401
12
CHAPTER 4. PARTICIPANTS, CODES, AND IDEALIZATIONS
A list of participants, along with the computer code used by each participant is provided in the
following Table:
In the following Sections each participant’s code and idealization are described.
4.1. Argentina
The FIREBIRD III MOD1-77 digital computer program [2] is a general network code
developed primarily for predicting the thermalhydraulic behaviour of a CANDU power
reactor plant during a postulated loss of coolant accident and the subsequent emergency
coolant injection.
Because of its generality, the code can also be used to solve a large variety of general
two-phase flow problems.
The code models the physical system in terms of a set of interconnecting nodes. A node
corresponds to a user-defined segment of pipe, a component, or a boundary condition in
the system. The geometrical parameters required for a node are volume for the hydraulic
calculation, and pipe mass, pipe inside diameter and pipe thickness for the thermal
calculation.
The connection between two nodes is defined as a link. A link has geometrical
parameters of length, hydraulic diameter, pipe roughness, elevation, and flow area.
The mass and energy conservation equations are solved for nodes. Quantities such as
pressure, density, internal energy, temperature, void fraction, static quality and enthalpy,
pipe and fuel temperature distribution, heat transfer and heat transfer coefficient, and
pump heat are node properties.
The momentum equation is solved for links. Quantities such as flow, drift flow, flow
quality and enthalpy, friction factor, two-phase multiplier, pump head, pump speed, and
pump torque are link properties.
The core of FIREBIRD III MOD1-77 contains generalized algorithms for solving the mass,
momentum and energy conservation laws associated with mass and heat transfer in a piping
network, as well as constitutive relationships such as slip and drift and heat transfer
coefficient correlations.
13
In order to model particular systems and event sequences, FIREBIRD III MOD1-77 code is
structured to include a set of user subroutines which a user adapts to provide specific
component models, control logic or boundary conditions for a given problem.
The code couples these boundary conditions and control logic with its fluid flow
conservation equations, fluid state equation, and constitutive relationships to form the
governing equations for the system being analyzed.
Since the problem-dependant programming is transferred to the user routines, different
sets of user routines for various problems can be handled with a single reference code.
The boundary conditions and control logic could be in the form of pressure-enthalpy
boundary conditions, flow-enthalpy boundary conditions, breaks in pipes, valve actions,
pump condition changes, and fuel power variations.
In the hydraulic calculations, an implicit numerical integration technique is used to solve the
one-dimensional three-equation fluid flow conservation equations together with the fluid state
equation.
In the code, both light water and heavy water properties are available, and the two-phase
fluid is assumed to be in thermal equilibrium. However, to account for the effects of the
relative phase velocity, a drift-flux model with several slip and drift correlations is
included in the code. The thermal non-equilibrium effect is accounted for in the pressure
calculation through an adjustment of fluid property derivatives.
In the thermal calculations, a one-dimensional heat conduction equation is solved
implicitly to obtain the heat transfer to the coolant and the temperature distribution
within the pipe and the fuel. The resulting heat transfers to the fluid are then coupled
explicitly with the hydraulic calculations.
Program version
FIREBIRD-III MOD1-77 VER 0.131
The program uses the Atomic Energy of Canada Limited library routines SORTAG, XTIME,
MFID, JOBNAME, TRIEQN, AND CHNGFX.
14
Name and establishment of authors
M.R. Lin, et al, Atomic Energy of Canada Limited, CANDU Operations, Sheridan Park
Research Community, Mississauga, Ontario L5K 1B2.
The FIREBIRD idealization of RD-14M for modelling Test B9401 consisted of a nodalization
briefly described in the following sub-sections.
Feeders
Observing actual feeders shape led to a different number of nodes for representing each pair
of them (see Figure 4.1):
Number of Nodes
Inlet Feeder Outlet Feeder
HS 5 – HS 10 4 4
HS 6 – HS 11 4 5
HS 7 – HS 12 6 7
HS 8 – HS 13 5 7
HS 9 – HS 14 7 7
End-fitting simulators
Geometrical parameters were observed as far as possible. The model consisted of 3 nodes: one
for the annulus, one for the stagnant volume, and one for the lateral pipe. The way in which
these three volumes were configured is shown in Figure 4.2.
Each fuel element simulator was modelled with 12 nodes, one per heated section (Figure 4.2).
Power generation
A power transient was defined as a boundary condition for each individual test section,
applying a “decay factor” obtained by dividing total power at present time step by initial total
power.
Headers
15
All pipes connected to headers (feeders, pump discharge, ECC pipes, pressurizer line) were
linked to the corresponding node, as it is shown in Figure 4.3.
Steam generator inlets; pump suctions and pump discharges were represented by one node
each (Figure 4-1)
Steam generators
The steam generators’ primary side was represented as follows (Figure 4.1):
The U-tubes were divided in 7 nodes, one of them corresponding to the preheater zone.
The boiler inlet and outlet plena consisted of 1 node each.
Pressurizer
This component was implemented in this model as a boundary condition for its interaction
with the primary system.
Secondary side
The secondary side of the steam generator was included as a boundary condition, where
pressure and temperature evolution were defined.
Feedwater flow and steam flow were also treated as boundary conditions.
Sixteen nodes were used for representing the operation of both phases of the ECC system:
high-pressure pumped ECC and low-pressure recovery phase ECC.
ECC tank TK2 and water proceeding from distilled water tanks were considered as boundary
conditions, as well as the return line to TK2.
16
FIREBIRD Subroutines Modified for Modelling RD-14M Test B9401
User subroutines
The following user subroutines were modified in order to complete the simulation model:
Subroutine PUMPAN (which belongs to the group of reference code subroutines) was also
modified for modelling primary pumps during rundown.
Break Model
(2) The Henry-Fauske two-phase critical flow model for a sharp edge orifice
(3) Critical discharge through a sharp edge orifice for superheated steam
FIREBIRD is mainly intended to be used for modeling heat storage and release from the core
of a nuclear reactor. The model available in the code can simulate fuel and sheath temperature
transients in what is referred to as a fuel model.
However, the RD14-M heaters have a heat capacity close to that of CANDU reactor fuel and
therefore the FIREBIRD fuel model was applied for the simulation, with the heaters treated as
if they were actual fuel elements.
17
Fuel model
The code solves the fuel dynamics equation by an implicit finite-difference method.
Mathematical model
Cylindrical co-ordinates (r,θ,z) with the Z axis (r=0) placed at the fuel centerline are
considered. Neglecting all axial and angular non-uniformities, the governing transient heat
conduction equation becomes:
∂T 1 ∂ § ∂T ·
C⋅ = ⋅ ⋅¨k ⋅r ⋅ ¸+Q
∂t r ∂r © ∂r ¹
Numerical technique
The temperature field is represented by a set of discrete values defined at some fixed radial
positions:
Ti ( t ) = T(ri , t ) i = 1,2,....
Each temperature, Ti, is associated with a ring of material extending from ri-1/2 to ri+1/2.
Current capabilities
Nodalization
Average pin power and heat transfer coefficient based on homogeneous coolant.
The resulting total power to coolant provides the coupling between the fuel dynamics
and hydraulics.
This effect is estimated by calculating the temperatures of a hot pin located at each of
the user specified elevations (levels).
18
Data for fuel heat calculation
Number of vertical regions of each fuel node for hot pin level fuel calculation.
Number of regions of equal radial thickness.
One region is assumed for the sheath.
Thermal properties
Constant
Variable: determined dynamically by the code
The initial conditions for Test B9401 simulation are presented in Table. 4.2. These are the
results of a steady state calculation that implied 2 consecutive runs: an actual steady state run
followed by a “do nothing” transient run (transient calculation without any perturbation).
This table lists some calculated variables as well as some quantities that were imposed as
boundary conditions. The experimental values are included for comparison (measured
quantities at time = 10 s, before experiment initiation).
Table 4.3 shows the sequence of events imposed for the transient calculation.
Table 4.1. Main Dimensions of the FIREBIRD Nodalization Developed for RD-14M
No QUANTITY VALUE
1 Total number of nodes 372
2 Total number of links 375
3 Number of nodes for each feeder 4-7
4 Number of nodes for end-fitting simulators 3
5 Number of nodes for each fuel element simulator 12
6 Number of nodes for each header 4
Steam generator inlet 1
Number of nodes for
7 Pump suction 1
above header piping
Pump discharge 1
Number of nodes for Inlet plenum 1
8 steam generators U-tubes 7
(primary side) Outlet plenum 1
Number of nodes for Emergency coolant injection
9 16
system
19
Table 4.2. List of Relevant Initial Conditions for Test B9401 Simulation
20
Fig. 4.1 Primary System Model.
21
Fig. 4.2. Below Header Model.
22
Fig. 4.3. Headers Model.
23
Fig. 4.4. Emergency Coolant Injection System Model.
24
4.2. Canada
The acronym CATHENA stands for Canadian Algorithm for Thermalhydraulic Network
Analysis. The CATHENA code was developed by Atomic Energy of Canada Limited (AECL)
[3].
Interface mass, energy and momentum transfer between the liquid and vapour phases are
specified using constitutive relations obtained either from the literature or developed from
separate-effect experiments.
The thermalhydraulic model in CATHENA includes pipe, volume, T-junction, reservoir and
tank components. The pipe component is the main thermalhydraulic component and consists
of one or more "nodes" where volume-related dependent variables (void fraction, pressure,
phase enthalpy and noncondensable mass fractions) are calculated. These nodes are connected
by "links" where the phase velocities are calculated. Volume components are used at the
connection of multiple pipe components to more accurately calculate the pressure and flow
distribution through the junction. T-junctions are used at the junction of three pipe
components to calculate pressure loss coefficients that are dependent on the flow distribution
(splitting or combining). Reservoir components are used to establish boundary conditions for
a simulation. Tank components were developed to model pressurizers, Pressurizers and other
vessels. The model assumes the tank can be divided into upper and lower regions. A two-fluid
model is used to represent mass and energy conservation in each region and as a result non-
equilibrium conditions can be modelled. The fluid (both vapour and liquid) momentum within
the tank, however, is neglected and the pressure difference between the upper and lower
regions is represented by a hydrostatic pressure balance.
The CATHENA code includes thermophysical properties for both light water (H2O) and
heavy water (D2O). The pressure range of application of the fluid properties is from the triple-
point pressure (611.73 and 660.1 Pa for H2O and D2O, respectively) to the critical pressure
(22.0 and 21.66 MPa for H2O and D2O, respectively). The temperature range of light water
properties is from 0°C to 2000°C and the temperature range of the heavy water properties is
from 0°C to 800°C. The thermodynamic properties for light water are within 1.5% of values
25
obtained from the US National Bureau of Standards (NBS) steam table generating functions,
Kestin et al. [4], and the property derivatives are within 5%. For vapour temperatures above
2000°C, the properties are obtained using the ideal gas approximation. The thermodynamic
properties for heavy water are within 1.5% of the values obtained from the generating
functions of Hill et al. [5] and the property derivatives are within 5%. For temperatures above
800°C, the ideal gas approximation is used.
Noncondensable gas properties for H2, He, N2, Ar, CO2 and air are available in CATHENA.
The thermodynamic properties for the noncondensable gases are assumed to obey the ideal
gas law. The vapour-noncondensable gas mixture is assumed to obey Gibbs-Dalton
thermodynamic relationships.
The comprehensive solid heat-transfer package used to model pipes or fuel in contact with the
fluid has been given the acronym GENHTP; which stands for GENeralized Heat Transfer
Package. The heat transfer package includes radial and circumferential conduction, thermal
radiation and contact conduction between solid surfaces. The zirconium-steam reaction is
included as a heat source (the H2 resulting from the reaction is also calculated). The heat
transfer package also includes a pressure-tube deformation model to account for expansion of
a pressure tube resulting in either rupture or contact with the calandria tube. The heat-transfer
package allows the connection of multiple solid surfaces of a heat transfer model to a single
thermalhydraulic node or multiple thermalhydraulic nodes. As a result, very detailed
modelling of a CANDU channel containing horizontal fuel bundles can be performed. Testing
of CATHENA/GENHTP has shown high computational efficiency, as well as the advantage
of closely coupling thermalhydraulic and fuel/channel behaviour. Heat transfer in deformed
geometries (pressure tube/calandria tube/moderator, fuel element/pressure tube, etc.) may be
modelled. One code, CATHENA, may be used for modelling the system thermalhydraulics, as
well as detailed heat transfer modelling of a CANDU fuel channel.
The CATHENA code also includes system models for components like tanks, pumps, valves,
emergency coolant injection accumulator, user definable junction resistances, and separators.
Also included in the set of system models is a point-reactor kinetics model, a break-discharge
model and a heat-balance calculation model. An extensive control system modelling
capability is also provided for complete loop simulations (i.e. regulation and safety shutdown
systems).
The thermalhydraulic code CATHENA was developed primarily for the analysis of postulated
upset conditions in CANDU reactors; however the code has found a wider range of
applications for the modelling of thermalhydraulic test facilities such as RD-14M, the
Blowdown Test Facility and the CHAN Thermal-Chemical Test Facility, as well as research
reactors such as MAPLE, NRU and McMaster Research Reactor.
The CATHENA idealizations of the RD-14M facility primary and secondary side are shown
in Figures 4-5 to 4-8. The CATHENA idealizations of the RD-14M facility ECC system
common piping, and Darlington NGS modes are shown in Figure 4-8. A brief description of
the primary side, secondary side and the ECC systems are presented in the following sub-
sections.
26
Overview
The CATHENA idealization used to simulate test B9401 consisted of 530 thermalhydraulic
nodes, 546 links and 179 wall heat transfer models. The calculation was performed with
CATHENA MOD 3.5d/Rev 0, required approximately 17,000 simulation time steps for the
400 s transient, and took 1.0 hrs CPU time (PC Pentium III, 1063 Mz.).
The Henry-Fauske discharge model was used to simulate the break. In these simulations, a
mixed flow regime was specified at the headers, the primary pumps discharge, and the
secondary-side of the steam generators using the 'FIX-MIXED' option. The CATHENA flow
regime map was developed primarily for fully developed flow along the axis of open pipes
and pipes containing fuel bundles. At these locations, this is not the case and mixed flow
conditions are expected for most of the transient.
Primary-Side Idealization
The RD-14M primary side consists of all piping connecting the headers, heated sections,
steam generators, pumps and pressurizer. The idealization used to model the primary-side
piping is shown in Figures 4-5 and 4-6.
In developing the primary-side idealization, the volume, length, flow area and elevation
change of each CATHENA pipe component resembled, as closely as possible, the RD-14M
test facility. This ensured that the fluid transit time and hydrostatic pressure changes around
the loop were represented accurately in the simulation. Since CATHENA is a two-fluid code,
horizontal and vertical sections of piping were not combined as one inclined pipe component,
unless the horizontal or vertical sections were very short. The principal reason for the
segregation between horizontal and inclined pipe sections was that the flow regime map used
in each is quite different. Sections of piping that were inclined, but varied in the degree of
inclination, were combined to simplify the idealization. The total volume of the primary-side
idealization, excluding the pressurizer and the line connecting it to the primary loop, has been
compared with the volume of the facility and found to be within 1 %.
The flow area of complicated geometries, such as the end fittings, boiler plenums and primary
pumps were determined by dividing the volume of the component by the flow path length.
This method proved to be acceptable provided the fluid velocities were not significantly
different from those in the facility. Modelling of headers, using this procedure to account for
the dead-end volumes, was not acceptable for this reason. Therefore, the dead volumes at the
ends of the headers were modelled as separate pipe components with one closed end.
Complicated geometries and intrusions into the fluid flow path of temperature measurement
devices caused difficulties in determining values for the minor loss coefficients.
The heat transfer models in the GENeralized Heat Transfer Package (GENHTP) were used to
model all solid components in contact with the fluid. They also account for the heat transfer
from the primary fluid to the pipe walls and from pipe walls to the environment, or in the case
of the steam generator tubes, to the secondary side. Pipe radii (inner and outer) were used in
defining the metal mass and heat transfer area in contact with the primary fluid. The thermal
properties used for the piping materials were obtained from CATHENA's internally stored
temperature-dependent thermal properties. Heat losses to the environment were modelled by
applying heat transfer coefficients, and a reference temperature of 20°C to the outside of
piping components.
27
The heated section was modelled using a single pipe component divided into 6 equal length
thermalhydraulic nodes. The 7-element FES bundle was represented by 3 "cylinder groups" to
model the heat transfer split between the liquid and vapour phases under stratified flow
conditions. The power distribution in the axial direction was assumed to be constant in the
CATHENA model.
The CATHENA thermalhydraulic code provides a number of "system control" models that
can be configured to perform the measurement and control functions of a reactor or the RD-
14M test facility. System control models were used in these simulations to control the opening
of the break, pressurizer isolation, heated section power rundown, primary pump speeds
rundown and opening of the four ECC isolation valves. Opening of the break and closing of
the pressurizer and ECC isolation valves was assumed to occur over a 0.1 s time span. Heat
section power and pump speeds were extracted from experimental data.
A trip model was used to simulate the switch from high pressure ECC to low pressure pumped
ECC. These functions are used to isolate the high pressure ECC line, open the pumped ECC
isolation valve and startup the low-pressure ECC pump.
The secondary-side idealization that was used to simulate these tests is shown in Figure 4-7.
This idealization includes the steam generators up to the steam nozzle and that part of the
feeder water line from the thermocouple location measuring the feedwater temperature to the
steam generator feedwater inlets. The portion of the feedwater lines, upstream of this location
was represented by flow and enthalpy boundary conditions. The secondary side steam
generator outlet pressures were modelled using the pressure boundary conditions obtained
from boiler steam dome pressures. Time varying feedwater flowrates, extracted from the
experimental results, were imposed as the flow boundary conditions.
Junction resistance models were used to account for head losses in the contraction at the top
of the riser section to the steam separator, expansion/contraction losses at the connection
between the external downcomer and the hot leg of the steam generator, the
expansion/contraction losses at the connection between the external downcomer and the steam
drum and the resistance of the steam generator. Separator models were used to simulate the
liquid separation at the bottom of the steam drum, and steam separation in the spiral-arm
separator at the top of the steam drum. Valve/orifice models were used to account for the
orifice in the external downcomers and the flow resistance through the hole in the longitudinal
baffle box in the centre of the steam generators.
The CATHENA idealization of the ECC configurations is shown in Figure 4-8. The
idealizations of the ECC system included provision for both the high pressure ECC phase
(high pressure ECC tank or high pressure pump) and low pressure ECC phase (low pressure
pump) injection modes used in these experiments.
In the high pressure ECC phase, a polynomial pump head relation was used to characterize the
high pressure pump (pump 14) behaviour in the Darlington NGS injection mode. A flow
boundary condition was used to simulate the low pressure pumped ECC phase since it was
suspected that the low pressure pump (pump 8) cavitated during these experiments. In these
idealizations, the total predicted ECC flowrates were used to calculate a level in the ECC tank.
Once the calculated level reached the ECC tank low level point, (-0.27 m), a switchover to
28
low pressure pumped ECC was initiated as in the experiments. A trip model was used to
initiate the operation of the isolation valve in the main high-pressure line to accomplish the
switchover to low pressure pumped ECC mode.
Tables 4-4, 4-5, and 4-6 give the main dimensions of the CATHENA nodalization, a
comparison of experimental and predicted initial conditions, and the boundary conditions
applied to the calculation.
29
Table 4.4. Main Dimensions of the CATHENA Nodalizations Developed for the RD-14M
Table 4.5. List of Relevant Initial Conditions Measured and Calculated for the RD-14M,
B9401 Experiment
No QUANTITY UNIT EXP CALC NOTES
1 Pressurizer pressure MPa 9.9 10.10
2 HD5 pressure MPa 10.0 10.10
3 DP (HD8-HD5)/(HD6-HD7) MPa 1.3-1.5 1.49 / 1.55
4 SGs pressure MPa 4.5 4.52
5 MCP1 flowrate Kg/s 21.9 21.81
6 MCP2 flowrate Kg/s 21.6 22.13
7 HS5 mass flowrate Kg/s 4.0 – 4.1 4.10
8 HS6 mass flowrate Kg/s 4.0 – 4.1 4.03
9 HS7 mass flowrate Kg/s 4.5 – 4.8 4.94 Fed by MCP1
10 HS8 mass flowrate Kg/s 4.5 – 4.8 4.93
11 HS9 mass flowrate Kg/s 4.0 – 4.1 3.90
12 HS10 mass flowrate Kg/s 3.9 – 4.0 4.02
13 HS11 mass flowrate Kg/s 4.0 – 4.0 3.99
14 HS12 mass flowrate Kg/s 4.5 – 4.8 5.08 Fed by MCP2
15 HS13 mass flowrate Kg/s 4.5 – 4.8 4.89
16 HS14 mass flowrate Kg/s 3.9 – 4.0 3.92
17 SG1 SL flowrate Kg/s 1.9 1.91
18 SG1 FW flowrate Kg/s 2.1 1.91
19 SG2 SL flowrate Kg/s 2.0 2
20 SG2 FW flowrate Kg/s 2.5 2
21 SG1 DC flowrate Kg/s - -
22 HD5 / HD7 fluid temperature °C 295 297 / 296
23 HD8 / HD6 fluid temperature °C 262 261 / 260
24 SG1 fluid temperature °C - 257.3
25 FW temperature °C 187 187
26 Void fraction at HS5 outlet - - 0.
27 Void fraction at HS8 outlet - - 0.
30
Table 4.6. List of Relevant Boundary Conditions Measured and Adopted in the Calculation of
the RD-14M, B-9401 Experiment
BO1UP1 BO1DN1
BO2UP1 BO2DN1
Pump 1 Pump 2
IBO1PL OUTP1 OUTP2
OBO1PL IBO2PL OBO2PL
OPMP1 OPMP2
OBO1A OBO2A
IBO1B IBO2B
INP1 INP2
IBO1A IBO2A
OBO1B OBO2B
OH7RLF
Inlet Header 6
Outlet Header 7
ECI6C IH6A IH6B IH6C IH6D OH7A OH7B OH7C OH7D ECI7C
SURGTK
Inlet Header 8
OH5RLF
ECI8C IH8A IH8B IH8C IH8D BKBC
SURGE1
SURGE3 Outlet Header 5
SURGE2
OH5A OH5B OH5C OH5D ECI5C
SURGE4 SURGE5 HS11 HS12
SURGVLV HS10 HS13 HS14
Hs11 HS13
HS10 HS12 HS14
31
Fig. 4.6. CATHENA Idealization — Primary System, Below Headers.
SEC10BC
BO1ROZ
Steam
SEPARATOR
BO1DRUM
BO1RS4
W
at
er
BO1DN2
BO1RS3
BO1UP2
BO1DN C
DOWNCOMER
BO1RS1 BO1RS2
BO1PREH
PREHEATER
BO1BAFB
BO1DN1
BO1UP1
SECTION
BO1BAF
BO1INL
IBO1PL OBO1PL
PRIMARY SECI1BC
FLOW
IN OUT
32
ECITANK
ECIHPBC
ECTHP1 ECIP14I2
ECIPUM2 NV-14 ECIHP3 MV11 ECIHP2 P14
ECIP14I1
ECIPUM3 ECIHP4 MU22
ECIPUM4
ECICOM0
ECIP1403
ECIPUM1
ECIP1401
ECICOM1 NV-9
ECIP1402
OR-25
ECIP8
ECICOM2
ECPUMBC
ECICOM3 ECICOM4
ECICOM5
ECICOM6
ECI56A ECI78A
ECI56B ECI78B
NV-5
MV-5 MV-7
33
4.3. India
RELAP5 was developed at the Idaho National Engineering Laboratory for the U.S. Nuclear
Regulatory Commission (NRC). RELAP is basically developed for LWR transient analysis.
However, the code’s generalization has enabled its application to both nuclear and non-
nuclear fields, horizontal and vertical types of reactors, and light and heavy water reactors. Its
nuclear specific applications include simulations of transients such as loss of coolant
accidents, anticipated transients without scram (ATWS) and operational transients such as
loss of feedwater, loss of offsite power etc.
The RELAP5/MOD3 code is based on a nonhomogeneous and nonequilibrium model for the
two-phase system. It solves unsteady and one-dimensional mass, energy and momentum
equations for each phase based on a fast and partially implicit finite-difference numerical
scheme. The code includes many generic component models such as pumps, valves, pipes,
heat releasing or absorbing structures, reactor point kinetics, electric heaters, jet pumps,
turbines, separators, accumulators, and control system components. In addition, special
process models are included such as form loss, flow at an abrupt area change, branching,
choked flow, boron tracking, and noncondensable gas transport.
The difference equations are based on the concept of a control volume (or mesh cell) in which
mass and energy are conserved. This results in defining mass and energy volume-average
properties and requires knowledge of velocities at the volume boundaries. The velocities at
boundaries are obtained through the use of momentum control volumes (cells) centered on the
mass and energy cell boundaries. Therefore, the scalar properties (pressure, energies, and void
fraction) of the flow are defined at cell centers, and vector quantities (velocities) are defined
on cell boundaries.
Heat structures represent the solid structures bounding hydrodynamic volumes (i.e. pipe
walls) or structures internal to the volumes (fuel pins). The one dimensional heat conduction
equation is used to compute temperature distributions within heat structures. Hydrodynamic
volumes and heat structure conditions are coupled through heat structure boundary conditions.
The constitutive relations include models for defining flow regimes and flow-regime-related
models for interphase drag and shear, the coefficient of virtual mass, wall friction, wall heat
transfer, and interphase heat and mass transfer. Heat transfer regimes are defined and used for
wall heat transfer.
The basic approach to pump modeling is to superimpose a quasi-static model for pump
performance on the RELAP5 volume-junction flow path representation. The pump is a
volume-oriented component, and the head developed by the pump is apportioned equally
between the suction and discharge junctions that connect the pump volume to the system. The
pump model is interfaced with the two-fluid hydrodynamic model by assuming the head
developed by the pump is similar to a body force. The pump head is coupled implicitly to the
volumetric flow rate.
34
4.3.2. The RELAP Idealization
DESCRIPTION OF MODELLING
The experimental and the auxiliary loop have been modelled in the RELAP5/MOD3.2 code. It
necessitates nodalization of the total system into a number of volumes and inter-connecting
junctions, valves, heat slabs and component-specific models such as pump, separator etc. The
system controls are modelled through trip cards, which accept logical inputs based on time,
pressure and other thermal-hydraulic parameters. The power trip, pump coast down, break
initiation, ECC pump activation etc are controlled through the trip cards.
Headers, Feeders and Channel discretization are shown in Figure 4.9. Each of the ten channels
is discretised into three axial volumes to obtain the axial distribution of thermal-hydraulic
parameters. Feeders are nodalised such that sections of the pipes having similar inclination
and cross-sectional area are combined. Each feeder has 13 to 14 volumes maintaining the pipe
length and elevation. In the setup, the intake and off-take branches such as ECC injection,
feeder connection, break valve, instrument inserts etc. are connected to the header at different
axial locations. Accordingly the header is discretised into three axial volumes (Figure 4.10).
Each fuel element consisting of center core of MgO, Inconel 625 heater tube, Boron Nitride
and outer S.S. Sheath, which transfers heat to the coolant, is modelled with a RELAP specific
heat generating Heat Structure Component. The seven fuel pins are combined into a single
fuel pin heat structure maintaining the surface area, mass and equivalent heated perimeter.
Axially, the fuel bundle is divided into three in accordance with the number of channel
volumes. The fuel pin is radially discretised into five regions simulating the different layers.
These fuel pins generate heat corresponding to each channel power. The power ramp down
during the transient is given in a tabular form in the code as reported in the experiment.
The primary side steam generator path in both the loops is shown in Figure 4.11 and
Figure 4.12. The Steam Generating U-Tubes are segregated into six volumes including two
inlet and outlet plenum volumes. Four of the U-Tube volumes are attached with four heat
slabs, forming the thermal linkage between the primary and secondary system. The secondary
system consists of riser, drum and downcomer volumes. A RELAP specific separator
component, attached with the drum volume, is used to separate out steam and water. The
drum volume is modeled using a pipe component having 10 volumes. The U-Tube heat slabs
are connected to the two volumes of the riser portion. One single volume downcomer
connects the drum inlet to the secondary riser inlet. The feed from a time-dependent volume is
injected into the riser portion and mixes with the saturated water from the downcomer. It
picks up heat from the U-tubes, converts into a two-phase mixture and rises in the riser
volume. At the exit of the riser this two-phase mixture enters the separator volume. Steam
from the separator moves to the upper portion of the drum volume and the saturated liquid
falls back into the lower portion of the drum volume. The bottom volume of the drum is
connected to the downcomer. The feed flow and temperature are given as a time dependent
boundary condition, as obtained in the experiment.
35
Pump Modelling
The primary pump is modelled using the RELAP in-built Bingham Pump characteristic. The
rated flow, speed and head are provided as given in the report. ECCS pumps of stage 1 and 2
are simulated using time-dependent junctions whose flow characteristics are given as
functions of downstream discharge pressure. This characterization is obtained from the report.
Pump coast down is simulated through a time vs. pump velocity lookup table as reported
during the transient.
Nodalization of the ECC system is shown in Figure 4.13. Only the high-pressure phase and
the recovery phase of the system are modelled as no gravity phase activation is observed
during the transient. Both the pumps are modelled as described in the previous section. The
number of volumes and junctions used closely simulate the experimental setup. The total
integrated ECC flow is used to calculate the accumulator inventory and level. As the level
decreases below 10 % in the accumulator tank, the low-pressure phase is activated.
36
Fig. 4.10. Header Discretization in RELAP5.
37
Fig. 4.11. PHT Discretisation between HDR7 and HDR8 in RELAP5.
38
Fig. 4.12. PHT Discretisation between HDR5 and HDR6 in RELAP5.
39
Fig. 4.13. ECCS Discretization in RELAP5.
40
4.4. Italy
The US NRC version of the RELAP5/mod3.2, ref. [6], is used for the post-test analysis of the
B-9401 LBLOCA experiment performed in the RD-14m test facility simulating a CANDU
reactor. RELAP5, together with TRAC, Cathare and Athlet is one of the four widely diffused
system codes available to the scientific community for transient analysis for the LWR. The
code solves six 1-D balance equations for mass momentum and energy, separately for the
steam and the liquid phases. It has the capability to model any complex thermalhydraulic
system including primary loop, secondary loop and Balance of the Plant systems in an LWR.
Control systems can also be simulated together with the 0-D neutron kinetics performance of
the core. The main reasons for the selection of the code can be stated (or repeated) as:
The ‘idealization’ is the result of a wide range brainstorming processes where the user
capabilities, the available computational power and the resources for the analysis, together
with the code features, play a fundamental role. Here the word ‘idealization’ is used as a
synonym of ‘nodalization’ that appears to have a broader diffusion within the international
community.
Two main nodalizations have been developed at the University of Pisa within the framework
of the participation to the analysis of the B-9401 RD-14m LBLOCA experiment. Their main
features as well as the differences are outlined in the two reports listed as refs. [13] and [14].
The first nodalization has been derived from the standard criteria proposed by the University
of Pisa for nodalization development and qualification as outlined in ref. [7]. Those criteria,
validated for PWR, BWR and VVER situations have been ‘adapted’ to the CANDU system
configuration.
The second nodalization, utilized for producing the reference RELAP5 code calculation
results by UNIPI, differs from the first one, owing to the following items:
A. The heated channel HS13 has been sub-divided into two hydraulic channels including
‘5 bottom’ pins and ‘2 top’ pins, respectively. These are connected by ‘cross-junctions’
and allow the simulation of stratification inside the channel.
B. The ECCS lines have been simulated: in the first nodalization (available from April 2001,
ref. [13]), ECC flow-rates were imposed as a function of time at each individual ECC port
in each header. In the present nodalization flowrate versus pressure is imposed at the
location where the high and the low pressure ECC system pumps are installed in the RD-
14M loop.
41
C. Flow-rates in the primary loop available from the experimental database have been
correctly interpreted (in the nodalization of April 2001, ‘l/s’ were interpreted as ‘kg/s’).
D. As a consequence of the above, MCP speed has been correctly set at 350 rpm (it was
372.6 rpm in the first nodalization).
E. One node has been added per SG to take into account the volume of the steam line
between each SG vessel and the main steam isolation valve location.
F. The ‘pin 5’ in heated section 7 and the ‘pin 7’ in heated section 12 were disconnected,
according to Table 3 of the document of H. Q. Zhou [15] discussed during the meeting
held in Vienna in May 2001.
G. Minor changes have been introduced to the SG level control to stabilize the initial steady
state.
H. The experimental value of the pressure drops between headers has been ‘better matched’
by the calculated results, by increasing the pressure loss coefficients through the channels
and connected piping.
I. The ‘heat transfer’ surfaces “110” and “134” for the calculation of the heat transfer
coefficient have been adopted in the heated section. However, further analyses may be
needed related to this user option.
The main dimensions of the two nodalizations can be found in Table 4.7 and the sketch of the
second nodalization is given in Figures from 4.14 to 4.17.
The boundary and initial conditions and the imposed sequence of main events adopted for the
final calculation, i.e. second nodalization, are given in Tables 4.8 and 4.9, respectively, where
a comparison is made with experimental data as applicable. It must be noted that the
calculated values in Table 4.8 are related to the end of the 100 s transient-steady-state
calculation. In addition, input power for individual heated sections are those reported in
Table 3 of reference [15]. In the case of the heated section 13, 2/7 and 5/7 power applicable
for that channel, are generated in the hydraulic channels 760 and 260 of Figure 4.16,
respectively.
42
Fig. 4.14. UNIPI Nodalization of RD-14M Suitable for RELAP5/MOD3.2 Code,
Overall System, Part I.
43
Fig. 4.15. UNIPI Nodalization of RD-14M Suitable for RELAP5/MOD3.2 Code,
Overall System, Part II.
44
Fig. 4.16. UNIPI Nodalization of RD-14M Suitable for RELAP5/MOD3.2 Code,
Detail of the HS13.
Table 4.7. Main Dimensions of the RELAP5/MOD3.2 Nodalizations Developed for the RD-
14M by UNIPI
45
Table 4.8. List of Relevant Initial Conditions Measured and Calculated for the RD-14M,
B-9401 Experiment
* Related to the Table 3A of the report DIMNP NT 432(01), experimental flowrate values of primary and
secondary loop quantities have been multiplied by 0.787 and 0.881 (kg/l), respectively, because original
experimental data were given in l/s (and not, as previously interpreted, in kg/s).
46
Table 4.9. List of Relevant Boundary Conditions Measured and Adopted in the Calculation of
the RD-14M, B-9401 Experiment
47
4.5. Republic of Korea
As the RELAP5 code was described in another section, the focus here is on the differences
between RELAP5 and RELAP5/CANDU. Several earlier assessment results of the RELAP5
code in the RD-14 tests indicated some deficiencies in the prediction of the heated section
sheath temperatures, etc. Therefore, the development of RELAP5/CANDU code was initiated
by the Republic of Korea Institute of Nuclear Safety in cooperation with the Republic of
Korea Atomic Energy Research Institute, to reduce the identified deficiencies. The
RELAP5/CANDU code is currently under development and until now, modifications have
been performed for the following areas:
Some of the above modifications had already been adopted in the RELAP5/MOD3.2 version.
Basically, in view of hydrodynamic model (fluid control volumes and junctions), a relatively
fine nodalization scheme is adopted for the components where two-phase phenomena and
system functions play important roles, and cross flow junctions are modeled where the flow
direction is vertically linked to the main flow direction such as at end fitting connections. The
system model was developed following reference to the various nodalizations in the
references and reflected experience in determining the nodalization of the systems. Also,
RELAP5 User's Guidelines were followed as closely as possible. In a heat structure, heat flow
paths modeled in a one-dimensional sense, and radial meshes are divided in order to get the
accurate temperature distribution. Heat structures were modeled for pipe walls, nuclear-fuel
pins simulator, heat exchanger surfaces, etc.
With the above general nodalization philosophy, the RD-14M facility was modeled. System
models for the RELAP5/CANDU calculation are shown in Figures 4.18 and 4.19, which are
basically similar to those found in the CATHENA model and therefore may help reduce the
effect of nodalization. The system model comprises the primary heat transport system
including heaters, pumps, secondary system, ECC system, and break model. The test section
was modeled in each channel and each steady state channel flowrate was tuned up.
The forward/backward junction loss coefficients were used to simulate pressure loss and in
the case of orifices, a junction abrupt area change model was used. High and low ECC pumps
were modeled as time-dependent junctions in which mass flow was controlled by discharge
pressure. In particular, the ECC piping was modeled in order to simulate the ECC flow-
splitting behavior. The break model was single normal junction and the discharge volume was
simulated by a time-dependent volume.
48
Table 4.10. Main Dimensions of the RELAP5/CANDU Nodalizations Developed for
RD-14M by KINS
No. QUANTITY RELAP5/ NOTES
CANDU
49
Table 4.11. List of Relevant Initial Conditions Measured and Calculated for the RD-14M,
B9401 Experiment
No QUANTITY UNIT EXP CALC NOTES
1 Pressurizer pressure MPa 9.9 10.05
2 HD5 pressure MPa 10.0 10.0425
3 DP (HD8-HD5)/(HD6-HD7) MPa 1.3-1.5 1.5/1.52
4 SGs pressure MPa 4.5 4.4
5 MCP1 flowrate * Kg/s 21.9 21.6
6 MCP2 flowrate Kg/s 21.6 21.7
7 HS5 mass flowrate Kg/s 4.0 – 4.1 4.07
8 HS6 mass flowrate Kg/s 4.0 – 4.1 3.9
9 HS7 mass flowrate Kg/s 4.5 – 4.8 5.1 FED BY MCP1
10 HS8 mass flowrate Kg/s 4.5 – 4.8 4.9
11 HS9 mass flowrate Kg/s 4.0 – 4.1 4.0
12 HS10 mass flowrate Kg/s 3.9 – 4.0 4.16
13 HS11 mass flowrate Kg/s 4.0 – 4.0 4.02
14 HS12 mass flowrate Kg/s 4.5 – 4.8 5.00 FED BY MCP2
15 HS13 mass flowrate Kg/s 4.5 – 4.8 4.98
16 HS14 mass flowrate Kg/s 3.9 – 4.0 3.9
17 SG1 SL flowrate Kg/s 1.9 2.7
18 SG1 FW flowrate Kg/s 2.1 2.7 Unreliable signal in ‘exp’
database
19 SG2 SL flowrate Kg/s 2.0 2.7 Unsteady situation from
‘exp’ database
20 SG2 FW flowrate Kg/s 2.5 2.7
21 SG1 DC flowrate Kg/s - 13.3 Unsteady quantity in ‘calc’
database
22 HD5 / HD7 fluid °C 295 295-296
temperature
23 HD8 / HD6 fluid °C 262 261-262
temperature
24 SG1 DC bottom fluid °C - 255
temperature
25 FW temperature °C 187 183
26 Void fraction at HS5 outlet - - 0.
27 Void fraction at HS8 outlet - - 0.
28 MCP speed rpm 350 372
29 SG1 DC level m 8.7 9.2 Unsteady quantity in ‘exp’
and ‘calc’ database.
Reference ‘0’ position not
identified in ‘calc’.
30 PRZ level m 1.27 1.31 Reference ‘0’ position not
identified in ‘calc’.
31 Core total power MW 8.14 8.14
* Related to the Tab. 3A of the report DIMNP NT 432(01), experimental flowrate values of primary and
secondary loop quantities have been multiplied by 0.787 and 0.881 (kg/l), respectively, because original
experimental data were given in l7s (and not, as previously interpreted, in kg/s).
50
Table 4.12. List of Relevant Initial Conditions Measured and Calculated for the RD-14M,
B-9401 Experiment
51
Fig. 4.18. RD-14M RELAP5/CANDU Nodalization.
52
To Steam
Generator 1 From Pump 2
Outlet Header 5 Inlet Header 8
525 520 515 510 685 680 675 670
343
301
143
189 193 101 155
151
139
105
201
135 109
123 121
159
185 131 125 113
341 305
173 171
243
241 207
251
239
209
223 221
235 255
293
259
289
335
321
323
53
4.6. Romania
The FIREBIRD-III MOD 1-77 was developed by Atomic Energy of Canada Limited [2].
The FIREBIRD-III MOD 1-77 program is a general network code developed primarily for
predicting the transient thermalhydraulic behaviour of CANDU reactor power plants during a
postulated loss of coolant accident with subsequent emergency coolant injection.
The code models the physical system in terms of a set of interconnecting nodes. A node
corresponds to a user-defined segment of a pipe, a component, or a boundary condition in the
system. Each node is specified by a label and by the following geometric parameters: volume
of coolant for the hydraulic calculation, and mass, pipe inside diameter, and thickness for the
thermal calculation. The connection between two nodes is defined as a link. A link is
characterized by the geometrical parameters of hydraulic length, hydraulic diameter, flow
area, elevation change (terminal node relative to initial node), absolute pipe roughness, and
loss coefficient. The mass and energy conservation equations are solved for nodes. Quantities
such as pressure, density, internal energy, temperature, void fraction, static quality and
enthalpy, pipe and fuel temperature distribution, heat transfer and heat transfer coefficient,
and pump heat are node-dependent. The momentum equation is solved for links. Quantities
such as flow, drift flow, flow quality and enthalpy, friction factor, two-phase multiplier, pump
head, pump speed, and pump torque are link-dependent.
In the code, a set of user routines is provided which allows the user to program various
boundary conditions and control logic for a given problem. The code will couple these
boundary conditions and control logic with its fluid flow conservations equations, fluid state
equation, and heat conduction equation to form the governing equations for the system being
analyzed. Since the problem-dependent programming is transferred to the user routines,
different set of user routines for various problems can be handled with a single reference code.
The boundary conditions and control logic could be in form of pressure-enthalpy boundary
conditions, flow-enthalpy boundary conditions, breaks in pipes, valve actions, pump condition
changes, and fuel power variations.
In the hydraulic calculations, an implicit numerical integration technique is used to solve the
one-dimensional three-equation fluid flow conservation equations together with the fluid state
equation. In the code, both light water and heavy water properties are available, and the two-
phase fluid is assumed to be in thermal equilibrium. However, to account for the effects of the
relative phase velocity, a drift-flux model with several slip and drift correlations is included in
the code. The thermal non-equilibrium effect is accounted for in the pressure calculation
through an adjustment of fluid property derivatives.
The FIREBIRD idealization of the RD-14M facility primary and secondary side is shown in
Figures 4-20 to 4-21. The FIREBIRD idealization of the RD-14M facility ECC system
54
common piping is shown in Figure 4-22. A brief description of the primary side, secondary
side and the ECCS models developed are presented in the following sub-sections.
4.6.2.1. Overview
The FIREBIRD idealization used to simulate test B9401 consisted of 387 thermalhydraulic
nodes and 399 links because the code is limited to a maximum number of nodes of 400. The
RD-14M idealization is presented from the perspective of the way the specific node and link
parameters were calculated.
The following options have been used: Bryce indicator for slip option and RELAP-UK
indicator for drift option. For all links in the model, the Martinelli-Nelson-Jones correlation is
used.
Each heated section is split in twelve nodes, corresponding to the 12 bundle positions.
The volume of coolant in one channel node is equal to one-twelfth of the empty channel
volume, minus the volume of the fuel bundles. The water volume for the outer nodes is
bigger due to a longer zone at the end of the channels.
The metal mass for the outer nodes is bigger due to a longer zone at the end of the
channels and due to the end caps.
The cross-sectional flow area is estimated by dividing the cooling volume by the core
length associated to a node. This method is used to maintain consistency with coolant
volume and pressure tube length. It leads to a more representative calculation of coolant
transit time across the core.
The value for each link segment between core nodes is simply the core length divided
by the number of link segments.
An effective hydraulic diameter is defined as four times the ratio of flow area to wetted
perimeter. The flow area used is the value calculated above. The wetted perimeter used
is the sum of that of the flow tube and the 7 fuel element simulators.
The inlet and outlet fittings are split in three nodes. Inside the end fitting, the coolant flows
around a liner tube. Coolant enters the shield plug via holes at the inboard end of the liner
tube, then either by the annulus outside the shield plug (stagnant volume) or through the
shield-plug holes to the flow tube. The reverse flow path is followed in the outlet end fitting.
A large volume of coolant in the dead space near the shield plug is normally stagnant. To
model flow in and out of the dead volume, a nodalization scheme, which uses a node to model
55
the dead space inside a node representing the end fitting body, is used. This node can act very
similar to a boiler node with calculations being made for heat transfer between the dead space
and the end fitting body. This representation incorporates the thermalhydraulic characteristics
associated with flowing and stagnant coolant, and the entire coolant volume.
There are four inputs in FIREBIRD-III MOD1-77 that determine the thermal properties of the
end fitting representation. These inputs are pipe inside diameter, pipe mass, pipe density, and
pipe thickness. From these input data, an effective heat transfer area is calculated.
node 1, between end fitting outer body and liner tube (annular zone)
node 2, inside liner tube, between coupling and shield plug (stagnant zone)
node 3, between shield plug and pressure tube.
The water volumes for nodes 1 and 3 were calculated as the product between cross-
sectional area and length. The water volume for node 2 is 3 liters.
The metal masses for nodes 2 and 3 were calculated as the product between density and
metal volume. The metal volume for node 2 was calculated as a sum between liner tube
volume, shield plug volume and end-fitting body volume behind the coupling minus the
holes volume inside the shield plug. The metal volume for node 3 was calculated as a
product between the pipe metal-sectional area and length. The metal mass for node 1,
was calculated as a difference between the total metal mass of 33.1 kg and the sum of
nodes 1 and 2 metal masses.
The diameter for the piping heat calculation is: end-fitting body inner diameter for node
1; liner tube inner diameter for node 2; and the pipe average inner diameter for node 3.
The appropriate thickness was determined by the other specified variables, using the
expression for effective heat transfer area.
The hydraulics of the end fitting divide naturally into two groups: the hydraulics
associated with the normal flow path of fluid, and the hydraulics associated with the
shield plug and the stagnant water.
There are 6 link segments in the inlet and outlet end fitting, since each FIREBIRD-III MOD
1-77 link is subdivided into two segments. However, since one of the nodes represents the
dead volume, there are actually only four link segments on the normal flow path.
The flow area for the link segments connected to node 1 is equal to the annular area
between the end-fitting body and the liner tube.
The flow area for the link segments connected to node 3 is equal to the cross-sectional
area, taking into account pipe inner diameter.
56
The hydraulic length for the link segments connected to node 1 is equal to half of
annular zone length. The hydraulic length for the link segments connected to node 3 is
equal to the pipes length from node 3.
An effective hydraulic diameter is defined as four times the ratio of flow area to wetted
perimeter.
The flow area for the link segment connected to node 2 is equal to the cross-sectional
area corresponding to the liner tube inner diameter.
The flow area for the link segment connected to node 3 is equal to the annular-sectional
area, between shield plug and liner tube.
The hydraulic length for the link segment connected to node 2 is equal to half of the
stagnant zone length.
The hydraulic length for the link segment connected to node 3 is equal to the shield plug
length.
An effective hydraulic diameter is defined as four times the ratio of flow area to wetted
perimeter.
Feeder Modeling
Each feeder was split in vertical and horizontal pipes and each pipe was modelled like a node.
The water volume was calculated as the product between the cross-sectional area and
pipe length.
The metal mass was calculated as the product between density and metal volume. The
metal volume was calculated as the product between the metal annular-sectional area
and the pipe length.
The diameter is equal to the pipe inner diameter or average pipe average inner diameter
(for pipes with different inner diameters)
The thickness was calculated as half of the difference between outer and inner diameter.
Each reactor header was split in three nodes to take into account pump/boiler and feeders
connection. The heat transfer area was calculated taking into account the end caps mass
(where applicable) and boiler/pump/ECCS/feeder connections.
For the links between two nodes of the inlet/outlet header the flow area, hydraulic length, and
hydraulic diameter were provided. The value considered for loss coefficient was zero.
57
The following data is provided for the header section of the links between inlet/outlet header
node and inlet/outlet feeder node or boiler/pump connections node:
The flow area is assumed to be equal to the pipe cross-sectional area connecting
feeder/pump/boiler to inlet/outlet header.
Hydraulic length is the header radius.
The hydraulic diameter is assumed to be equal to the pipe diameter connecting
feeder/pump/ boiler to inlet/outlet header.
The elevation difference is equal to the header radius corrected with the pipe angle.
A loss coefficient of 0.5 is assumed for pipe entrance and 1.0 for pipe exit.
The following data is provided for the header section of the links between inlet/outlet header
node and pressuriser/ECCS connection node:
The flow area is equal to the pipe cross-sectional area of the reactor header.
The hydraulic length is equal to the length between end cap and the first inlet/outlet
feeder connections to the reactor header.
The hydraulic diameter is equal to the reactor header inner diameter.
The elevation difference is zero.
The loss coefficient is zero.
Pressurizer Modeling
A single node is used to model the pressurizer. The piping connecting the pressuriser to the
RD-14M loop (pressurizer line) is modelled as one node.
The coolant volume in the pressurizer node is equal to the product between the cross-
sectional area and the length pipe.
The diameter used in the thermal calculation was taken equal to inner pipe/pressuriser
diameter.
Because there are pipes with different thickness in the pressurizer node, it is quite
difficult to estimate the thickness. Therefore, the thickness was calculated from the heat
transfer area equation. For the pressuriser node, it is equal to the pressuriser thickness.
In the RD-14M loop, there are two heat transport pumps. The standard data specified in
Reference 18 have been used.
58
Separate nodes are used to model the pump suction line (PS1/2), pump bowl (PM) and pump
discharge line (PD1/2). The node-link arrangement is shown in Figure 4-20. The pump is
modelled in the link between the pump suction and pump bowl nodes.
The coolant volume in nodes 1 and 3 is equal to the product between the cross-sectional
area and the pipe length.
The diameter used in the thermal calculation was taken equal to the inner pipe diameter
or the average inner pipe diameter (for different pipes in the same node).
Due to the irregular shape of the pump bowl and because there are pipes with different
thickness in the same node, it is quite difficult to estimate the thickness. Therefore, the
thickness was calculated from the heat transfer area equation.
The flow area is estimated as being the pipe cross-sectional area. The flow area for a
pump was taken the same as the neighbouring pipes.
The length value for each link segment corresponds to the pipe length. For a pipe node,
the hydraulic length was taken equal to the difference between the pump inlet/outlet
elevation and the pump core elevation.
An effective hydraulic diameter is defined as four times the ratio of flow area to wetted
perimeter. For pump links, the same hydraulic diameter as for neighbouring links was
taken into account.
In the model, the pipe between outlet header and boiler was split in three nodes to take into
account the angle of inclination of the pipe.
The water volumes were calculated as the product between the pipe cross-sectional area
and the length associated to the node.
The metal mass was calculated as the product between density and metal volume. The
metal volume was calculated as a product between the pipe metal-sectional area and
length.
The diameter for the piping heat calculation is the inner pipe diameter.
The flow area for the link segments is equal to the product between the tube cross-
sectional area and the length associated to each node.
The hydraulic length is equal to half of the length associated to each node.
An effective hydraulic diameter is defined as four times the ratio of flow area to wetted
perimeter.
59
Boiler inlet/outlet plenum
The flow area was calculated by dividing the cooling volume by the length between pipe
connection to boiler plenum and tubesheet. This maintains consistency with coolant
volume and length and leads to a more representative calculation of cooling transit time
across the core.
The hydraulic length was calculated as the difference between tubesheet elevation and
pipe connection elevation to boiler plenum.
An effective hydraulic diameter is defined as four times the ratio of flow area to wetted
perimeter (near tubesheet).
Minor losses are negligible, hence the loss coefficient in the connecting link sections is
taken to be equal to zero.
Boiler Tubes
The flow area for the link segments is equal to the product between the tube cross-
sectional area and the length associated to each node.
The hydraulic length is equal to half of the length associated to each node.
An effective hydraulic diameter is defined as four times the ratio of flow area to wetted
perimeter.
The height is equal to the length for vertical portions. For U-bend portions, the total
U-bend length of all boiler tubes was calculated based on Reference 3 for each boiler.
Minor losses are negligible, hence the loss coefficient in the connecting link sections is
taken to be equal to zero.
Only unplugged tubes are taken into account and they are modelled as one "average" tube. Six
nodes can be identified:
Vertical portion from inlet plenum through the tubesheet to the preheater end elevation,
Four portions of equal length:
one vertical portion starting from the preheater end elevation,
one vertical portion followed by a U-bend portion, ended by the U-bend top,
one U-bend portion starting from the U-bend top, followed by a vertical portion,
one vertical portion ended by the preheater end elevation,
Vertical portion from preheater end elevation through tubesheet to outlet plenum.
60
The metal mass was calculated as the product between density and metal volume. The
metal volume was calculated as a product between the pipe metal-sectional area and
length.
The diameter for the piping heat calculation is the inner tube diameter.
Each of two boilers is modelled as a single node. Each node is a lumped heat transfer node,
incorporating the downcomer, riser, internal preheater, and steam drum portion of the boiler.
Specific modelling of each of these components is contained in the user subroutines. The
steam pipes between each boiler and the steam balance header are each represented by one
node, as is the steam balance header itself. All flows into and from this system (boiler
feedwater, jet condenser steam flow), are modelled as flow-enthalpy boundary conditions.
Hence node and link geometrical data are only needed for the two boilers, the two steam pipe
nodes, and the single steam balance header node.
The parameters specified for nodes are coolant volume, and the three effective values for the
piping heat calculation -inner diameter of a representative cylinder, its thickness, and piping
mass.
Boiler node:
Volume: It includes the riser volume, downcomer volume, the volume above the bottom
of the separators, and the steam drum. These volumes are not modelled individually in
the one-node boiler model.
Metal mass: It was calculated as the sum of the shell metal mass, longitudinal baffle
metal mass and downcomer metal mass.
The heat transfer area was calculated as the sum of the heat transfer areas of the shell,
longitudinal baffle and downcomer.
The thickness was calculated from the heat transfer area equation.
This volume was calculated as a product between cross-sectional area and length.
Metal mass: It was calculated as the product between the pipe metal area and the pipe
length.
The diameter is equal to the pipe inner diameter.
Volume: This volume was calculated as a product between cross-sectional area and
length.
Metal mass: It was calculated as the product between the pipe metal area and the pipe
length.
The diameter is equal to the average pipe inner diameter.
61
Link data were calculated as follows:
All flows into and from this system (boiler feedwater, jet condenser steam flow) are modelled
as flow-enthalpy boundary conditions. Hence link geometrical data is only needed for the link
between the boiler node and the steam pipe node and between the steam pipe node and the
steam balance header node.
The flow area is estimated as being the steam pipe cross-sectional area.
The length for the link segment connected to the boiler node is equal to the steam space
height of the boilers. The length for the link segment connected to the steam pipe node
is equal to the pipe length.
The hydraulic diameter for the link segment connected to the boiler node was assumed
to be equal to the steam drum inner diameter. The hydraulic diameter for the link
segment connected to the steam pipe node was assumed to be equal to the pipe inner
diameter.
Between the steam pipe node and the steam balance header node:
The steam line connecting the balance header to the jet condenser is modeled by one link.
Since this link is connected to a flow-enthalpy boundary condition node, only the flow area
and the hydraulic diameter are specified for the terminal section. The pipe hydraulic
parameters are similar to the link segment parameters connected to the steam balance header,
on the link between the steam pipe and the steam balance header.
Figure 4-22 shows the nodalization for the ECCS model. The emergency core coolant system
is divided into two phases: high pressure injection and low pressure injection. During both
phases, the water is supplied by ECCS pumps. The high pressure injection will end when the
water level in the ECC tank TK2 reaches 10%. The low pressure pumped ECC phase ends
when the level in the distilled water tank falls below 50%.
Figure 4-22 also identifies the relevant control valves. All valve control logic is modelled in
the user subroutine USCOVL.
The ECC pumps head is calculated as a function from a flow versus head table, built on the
pump P14/8 performance curve (See Reference 3).
No piping heat calculations are performed for ECCS piping. Hence, the only node geometric
parameter input is volume.
62
Link data were calculated as follows:
Table 4.13. Main Dimensions of the FIREBIRD III MOD 1 Nodalizations Developed for
RD-14M
No QUANTITY VALUE NOTES
63
Table 4.14. List of Relevant Initial Conditions Measured and Calculated for the RD-14M,
B-9401 Experiment
64
Table 4.15. List of Relevant Boundary Conditions Measured and Adopted in the Calculation
of the RD-14M, B-9401 Experiment
65
Fig. 4.20. Primary Side Idealization.
66
Fig. 4.21. Secondary Side Idealization.
67
Fig. 4.22. Secondary side Idealization.
68
Fig. 4.23. ECCS Idealization.
69
CHAPTER 5. CODE COMPARISONS WITH EXPERIMENT
As discussed previously, test B9401 was characterized with over 558 measurements over the
duration of the experiment. A subset is required to make a meaningful comparison. A
proposed list of variables to be compared was prepared by Canada, and distributed to
participants in 2002 April, prior to the third meeting. Based on detailed discussions during this
meeting, a revised list was generated, and documented in [15]. Table 5-1 lists these selected
variables for the code intercomparison and validation. Exact locations of the measurement for
these variables can be found in [1] based on the “Device Code” given in Table 5. Data were
collected for 924 s in the experiment. However, only the first 400 s of the transient is used for
the intercomparison since the significant events occur in the first 400 s of the test B9401.
In the following sections the rationale for the selection of these variables is given followed by
a discussion of participant’s results compared to experiment.
Primary loop coolant circulation is provided by two high-head centrifugal pumps. In test
B9401, the break occurred at inlet-header 8 at 10 s, and the primary pumps were ramped
down starting at 12 s. The histories of ǻPP1 and ǻPP2 are a good indication of flow directions
across the pumps during the blowdown transient. Since the break occurred at the inlet-header
8, which is close to pump 2 outlet, ǻPP1 and ǻPP2 should demonstrate different behaviours.
Figures 5.1 and 5.2 provide the code comparison to experiment. In Figure 5.1 all calculations
show the proper trends. The peak differential pressure around 30 seconds is thought due to the
flow stagnation location. The flow stagnation location is a function of break flow, pump
forces and system hydraulic losses. In Figure 5.2 it is noted that Republic of Korea and
Argentina calculate a higher (and more correct) negative DP at about 30 s.
During the break, the primary pump speeds are reduced and ECC flow is initiated causing
flows to change dramatically in the primary heat transport system. Header differential
pressures (DP) provide an overall indication of flow directions in the below-header portion of
the loop (inlet feeders, outlet feeders and heated sections) during the blowdown transient.
Figures 5.3 and 5.4 provide the code comparison to experiment. In both Figures 5.3 and 5.4,
all calculations show the correct timing and trend, with the differential pressures being under-
predicted by some participants and over-predicted by others. It is noted that this DP will drive
the FES heatup in channels connected to these headers, with a smaller DP resulting in higher
temperatures.
71
Table 5.1. Selected Variables for Intercomparison
Order
Selected Variable RD-14M Device Var. of
Variables Description Channel Code Units Var.
Time s 1
ǻPP1 Pump 1 Differential Pressure (DP) 341 5Q-D1 kPa(a) 2
ǻPP2 Pump 2 DP 348 12Q-D1 3
ǻPHD8-5 DP from HDR8 to HDR5 336 35Q-D1 kPa(a) 4
ǻPHD6-7 DP from HDR6 to HDR7 338 36Q-D1 5
PHD8 Header 8 Pressure 179 10P-D1 MPa(a) 6
PHD6 Header 6 Pressure 323 4P-D1 7
PHD7 Header 7 Pressure 178 6P-D1 8
QP1 Pump 1 Discharge Flowrate 78 1F L/s 9
QP2 Pump 2 Discharge Flowrate 79 2F 10
Q5 ECC to Header 5 Flowrate 235 231F-D1 L/s 11
Q6 ECC to Header 6 Flowrate 237 232F-D1 12
Q7 ECC to Header 7 Flowrate 236 233F-D1 13
Q8 ECC to Header 8 Flowrate 238 234F-D1 14
QINT Integral of ECC Flows 92 1H L 15
72
2000
RD-14M
Argentina
Canada
India
Italy
Korea
1500 Romania
Pressure (kPa)
1000
500
Time (s)
Fig. 5.1. Pump 1 Differential Pressure.
2000
RD-14M
Argentina
Canada
1500 India
Italy
Korea
Romania
1000
Pressure (kPa)
500
-500
-1000
0 50 100 150 200 250 300 350 400
Time (s)
73
2000
RD-14M
Argentina
1500 Canada
India
Italy
1000 Korea
Romania
500
Pressure (kPa)
-500
-1000
-1500
-2000
0 50 100 150 200 250 300 350 400
Time (s)
Fig. 5.3. Header 8 to Header 5 Differential Pressure.
2000
RD-14M
Argentina
Canada
India
1500 Italy
Korea
Romania
Pressure (kPa)
1000
500
-500
0 50 100 150 200 250 300 350 400
Time (s)
Fig. 5.4. Header 6 to Header 7 Differential Pressure.
74
5.3. Pressures at Header 8, Header 6 and Header 7, PHD8, PHD6 and PHD7
Figures 5.5 to 5.7 provide the code comparison to experiment. All participants captured the
correct trend, with some participants predicting a more rapid depressurization in the first
100 s, and others predicting a less rapid depressurization.
Two primary pumps maintain coolant circulation in the primary loop. Apart from primary
pump differential pressures, pump flowrate is another variable that can be used to determine
loop flow direction changes during the transient. The flowrate measurement from the turbine
flowmeters (TFM) in test B9401 is a volumetric flowrate, and is recorded in L/s.
Figures 5.8 and 5.9 provide the code comparison to experiment. In Figure 5.8 it is noted that
two-phase conditions exist at the turbine flow meter early in the transient (Figure 5.17a), and
as such the measurement is not reliable. The peak flow at about 75s was predicted by most of
the participants. Pump 2 (Figure 5.9) “sees” two-phase flow at about 25s, and all calculations
show correct trend until this time. It is noted that turbine flow meters are only reliable in
single-phase flow. For this reason, Figure 5.9 only shows results to 25 s.
12
RD-14M
Argentina
Canada
India
10 Italy
Korea
Romania
8
Pressure (MPa)
0
0 50 100 150 200 250 300 350 400
Time (s)
75
12
RD-14M
Argentina
Canada
10 India
Italy
Korea
Romania
8
Pressure (MPa)
0
0 50 100 150 200 250 300 350 400
Time (s)
Fig. 5.6. Header 6 Pressure.
12
RD-14M
Argentina
Canada
10 India
Italy
Korea
Romania
8
Pressure (MPa)
0
0 50 100 150 200 250 300 350 400
Time (s)
Fig. 5.7. Header 7 Pressure.
76
150
RD-14M
Argentina
Canada
India
Italy
100 Korea
Romania
50
Flowrate (L/s)
-50
-100
0 50 100 150 200 250 300 350 400
Time (s)
120
RD-14M
Argentina
Canada
India
100 Italy
Korea
Romania
80
Flowrate (L/s)
60
40
20
0
0 50 100 150 200 250 300 350 400
Time (s)
77
5.5. Header ECC Flowrates, Q5 through Q8
Since the depressurisation rates vary from header to header, the timing and flowrates of ECC
to each header are different. ECC flowrates to each header (Q5 through Q8) are important for
analysing ECC system behaviour, and more importantly, for analysing the fuel channel
behaviour.
Figures 5.10 to 5.17 provide the code comparison to experiment. Emergency core coolant
(ECC) is connected both to the broken & unbroken loops, and the codes all calculate this split.
Some deviation is noted amongst participants, as ECC flows depend on the calculated
pressure drop around the loop. It is noted that all participants predict the initiation of ECC
flow accurately to Header 8 (break location). However, most calculations predict flow to other
headers at a time before the experiment.
The participants noted that modelling of the ECC system was not always consistent with the
experimental evidence. This was certainly true of the low-pressure ECC system, and this was
resolved in an additional calculation. Further investigation was recommended by the
participants. However, because overall system performance was predicted satisfactorily, no
additional work was performed in this project.
Integrated header ECC flowrates provides the total volume of fluid that comes from the ECC
system to the primary loop. It is important since it has a direct impact on primary loop
pressure, quenching of the fuel channels, FES sheath temperatures and mass inventory of the
primary system.
Figure 5.18 provides the code comparison to experiment. All participants show excellent
agreement with experiment during the high-pressure ECC, with India slightly under predicting
flows during this time. Some differences are noted in the later part of low-pressure ECC (after
200 s), although this condition is specified as a boundary condition. It is not expected that
these deviations would affect system behaviour significantly.
78
20
RD-14M
18 Argentina
Canada
India
16
14
Flowrate (L/s)
12
10
Time (s)
12
RD-14M
Italy
Korea
Romania
10
8
Flowrate (L/s)
Time (s)
79
10
RD-14M
Argentina
Canada
8 India
6
Flowrate (L/s)
-2
-4
Time (s)
8
RD-14M
Italy
Korea
Romania
6
4
Flowrate (L/s)
-2
-4
Time (s)
80
12
RD-14M
Argentina
Canada
10 India
8
Flowrate (L/s)
Time (s)
10
RD-14M
Italy
Korea
Romania
8
6
Flowrate (L/s)
Time (s)
Fig. 5.15. ECC to Header 7 Flowrate.
81
20
RD-14M
Argentina
18 Canada
India
16
14
Flowrate (L/s)
12
10
Time (s)
24
RD-14M
22 Italy
Korea
Romania
20
18
16
14
Flowrate (L/s)
12
10
8
6
4
2
0
82
5000
4000
Integral of ECI Flows (L)
3000
2000
RD-14M
Argentina
1000 Canada
India
Italy
Korea
Romania
0
0 50 100 150 200 250 300 350 400
Time (s)
Boilers are heat sinks in a heat transport system under normal operation. However, they may
behave as heat sources later in the transient. Void fractions at the inlets of the boilers (Į1 and
Į2), combined with primary pump differential pressures, provide important information
regarding ECC flow arrival to the primary heat transport system and subsequent voiding.
For all comparison of calculated void fraction with experiment, this comparison is made at a
particular node and the experiment. Participants noted that in some cases, neighbouring nodes
could have a significantly different void-fraction history — that provided better agreement
with the experiment. One possible reason for these discrepancies could be the occurrence of
choked flow in the feeders (specifically in the feeder orifices), and the inability of the codes to
predict this behaviour correctly.
Figures 5.19 to 5.22 provide the code comparison to experiment. In Figures 5.19 and 5.20 all
calculations show voiding by about 25 s. India, Republic of Korea, and Romania also
correctly show the passage of a slug of water (at about 75 s in the experiment). In Figures 5.21
and 5.22 all codes show experimental trends adequately for the first portion of the transient (to
75 s). However, for the later part of the transient, some calculations showed significant void,
in contrast to the experiment.
83
5.8. Primary Pump 1 and 2 Outlet Void Fractions, Į3 and Į4
Void fractions at the outlets of the primary pumps (Į3 and Į4) show voiding condition in
response to sudden depressurisation of the primary heat transport system at the primary pump
discharges, and they also show the timing of the ECC flow front movement.
Figures 5.23 to 5.26 provide the code comparison to experiment. In Figures 5.23 and 5.24, it
is seen that all agree with experimental tends. All codes show the initial voiding correctly,
with some disagreement after this point, ranging from total void to no void at all (Romania,
India). Overall, a wide range of results can be expected – as driving forces are very small, and
results can be affected. This can be seen in differences in Pump1 vs. pump 2, as one has
higher DP. In Figures 5.25 and 5.26 all predictions are seen to be in good agreement, with the
exception of a few calculations in the later part of the transient.
1.0
0.8
Void Fraction
0.6
0.4
RD-14M
0.2 Argentina
Canada
India
0.0
Time (s)
Fig. 5.19. Boiler 1 Inlet Void Fraction.
84
1.0
0.8
Void Fraction
0.6
0.4
0.2
RD-14M
Italy
Korea
0.0 Romania
Time (s)
Fig. 5.20. Boiler 1 Inlet Void Fraction.
RD-14M
Argentina
1.0 Canada
India
0.8
0.6
Void Fraction
0.4
0.2
0.0
Time (s)
85
RD-14M
1.0 Italy
Korea
Romania
0.8
Void Fraction
0.6
0.4
0.2
0.0
Time (s)
Fig. 5.22. Boiler 2 Inlet Void Fraction.
1.4
RD-14M
Argentina
Canada
1.2 India
1.0
0.8
Void Fraction
0.6
0.4
0.2
0.0
Time (s)
86
1.4
RD-14M
Italy
Korea
1.2 Romania
1.0
0.8
Void Fraction
0.6
0.4
0.2
0.0
Time (s)
1.2
1.0
0.8
0.6
Void Fraction
0.4
0.2
0.0
RD-14M
-0.2 Argentina
Canada
India
-0.4
0 50 100 150 200 250 300 350 400
Time (s)
87
1.2
1.0
0.8
0.6
Void Fraction
0.4
0.2
0.0
RD-14M
-0.2 Italy
Korea
Romania
-0.4
0 50 100 150 200 250 300 350 400
Time (s)
5.9. Boiler 1 and 2 Inlet and Outlet Fluid Temperatures, TB1-IN through TB2-OUT
Boiler inlet and outlet fluid temperatures provide local fluid temperature measurements in the
primary loop, can be used as confirmatory data for simulations, and they provide information
about heat removal/addition capability of the boilers during the blowdown transient.
Figures 5.27 to 5.30 provide the code comparison to experiment. All calculations show the
correct experimental trend, and all agree reasonably well with experiment for about the first
50 s of the transient. The lower temperatures in some calculations are due to the arrival of
low-temperature ECC flow. After that point, significant differences are noted.
88
300
RD-14M
Argentina
Canada
India
250 Italy
Korea
Romania
200
Temperature ( C )
o
150
100
50
0
0 50 100 150 200 250 300 350 400
Time (s)
300
RD-14M
Argentina
Canada
India
250 Italy
Korea
Romania
200
Temperature ( C )
o
150
100
50
0
0 50 100 150 200 250 300 350 400
Time (s)
89
300
RD-14M
Argentina
Canada
India
250 Italy
Korea
Romania
200
Temperature ( oC )
150
100
50
0
0 50 100 150 200 250 300 350 400
Time (s)
300
RD-14M
Argentina
Canada
India
250 Italy
Korea
Romania
200
Temperature ( oC )
150
100
50
0
0 50 100 150 200 250 300 350 400
Time (s)
90
5.10. FES Sheath Temperatures in Heated Sections 8 and 13, T1 through T5
The terms "broken pass" and "intact pass" are used to distinguish the two halves of the
RD-14M "figure-of-eight" primary circuit. For an inlet header break test, like B9401, the
broken pass is that portion of the primary loop between the outlet of pump 2 and the inlet of
pump 1, including the associated heated sections (10 through 14). The intact pass is that
portion of the primary loop between the outlet of pump 1 and the inlet of pump 2, including
the associated heated sections (5 through 9).
The maximum FES sheath temperature is often the most significant parameter in safety
analyses. In test B9401, the maximum FES sheath temperatures occur in the high power
channel of the broken pass, heated section 13 (HS13). The FES temperature excursions in
HS13 began immediately upon initiation of the break as flow in this channel dropped
significantly to a very low value (stagnated channel). The FES temperatures initially rose
quickly and then slowed as the heated channel power was reduced to decay levels beginning
at about 12 s. Shortly after the onset of the high-pressure ECC injection phase, quenching
began as ECC water arrived at the channel. The measured maximum FES temperature (T1) is
that of the top pin in the middle of HS13.
Since the ECC flow entered header 5 and the quench front moved from header 5, through
HS13, and towards the break on header 8, the outlet end of HS13 quenched more quickly than
the inlet end. Top pin FES temperatures at the inlet and outlet end of HS13 (T2 and T3) are
selected to demonstrate the difference.
When ECC flow enters the channel, significant time delays between quenching of bottom and
top pins in the horizontally oriented heated sections can occur depending on the liquid
flowrate. Top and bottom pin FES temperatures at the outlet of HS13 (T3 and T4) are chosen
to show the flow stratification in this test.
No significant FES temperature excursions were recorded in the heated sections within the
intact pass as channel flows remained high enough to maintain adequate cooling of the FES.
Heated section 8 (HS8) was the high power channel in the intact pass. The FES temperature at
the top pin in the middle of HS8 (T5) was selected to compare with the FES temperature at the
same location in HS13 (T1)
Figures 5.31 to 5.35 provide the code comparison to experiment. All codes captured the
temperature excursions, with mostly an over-prediction of peak temperature. It is noted that
the Republic of Korea calculation tended to under predict peak temperatures, while the
Romanian calculation showed a second temperature excursion for top pins. This is not
unexpected, as the temperature excursions are limited and of short duration (predicted
conditions are very near the critical heat flux (CHF)). For HS8 no major temperature
excursions (above steady-state values) were predicted which is consistent with the
experiment.
91
RD-14M
600 Argentina
Canada
India
Italy
500 Korea
Romania
Temperature ( C )
400
o
300
200
100
0
0 50 100 150 200 250 300 350 400
Time (s)
700
RD-14M
Argentina
Canada
India
600 Italy
Korea
Romania
500
Temperature( C )
400
o
300
200
100
0
0 50 100 150 200 250 300 350 400
Time (s)
92
800
RD-14M
Argentina
Canada
India
Italy
Korea
Romania
600
Temperature ( oC )
400
200
0
0 50 100 150 200 250 300 350 400
Time (s)
600
RD-14M
Argentina
Canada
India
500 Italy
Korea
Romania
400
Temperature ( C )
o
300
200
100
Time (s)
93
350
RD-14M
Argentina
Canada
300 India
Italy
Korea
Romania
250
Temperature ( C )
200
o
150
100
50
0
0 50 100 150 200 250 300 350 400
Time (s)
5.11. Void Fraction at the Inlet and Outlet of Heated Sections 5 and 13, Į5
through Į8
Channel void fractions are important because they indicate the onset of channel voiding and
the arrival time of the ECC to channels. This helps to explain the FES temperature behaviour
in the heated sections. It should be noted that inlet and outlet void fractions of the heated
sections were measured more than 2.0 m upstream and downstream of the heated section. In
test B9401, rapid and nearly complete voiding of all the heated sections in the broken pass
occurred upon initiation of the break at 10 s, whereas voiding of the heated sections in the
intact pass occurred at about 40 s. The ECC flow from header 5 refilled the outlet end, then
the inlet end of the heated sections in the broken pass. The ECC flow from header 6 refilled
the inlet, then the outlet of the heated sections in the intact pass. Void fractions at the inlet and
outlet of heated sections 5 and 13 (Į5 through Į8) are selected as representative of the channel
voiding and refilling scenarios of the intact and broken passes.
Figures 5.36 to 5.43 provide the code comparison to experiment. All calculations show the
initial voiding and refill being correctly predicted with differences noted between participants.
These discrepancies were expected, and thought to be due to the modelling of the endfitting
geometry with the various codes – noting the complexity of the endfitting geometry.
5.12. Pressure Drop across HS13, ǻPHS13, and Pressure Drop from HS13 to HDR5,
ǻPHS13-HD5
In test B9401, a flow split occurs in at least some of the heated sections of the broken pass
following the break. During the initial stage of the flow split, single-phase liquid flows out
94
both ends of the heated section while rapid voiding of the channel occurs. The volumetric
flow rates at the heated section inlet and outlet are measured using turbine flowmeters (TFM).
The TFMs are calibrated only to measure single-phase liquid flow and they commonly
become over-ranged during the blowdown when two-phase conditions are encountered. In test
B9401, shortly after the break, void was detected by the gamma densitometer at the test
section inlets and outlets near the turbine flowmeters and at the primary pumps. The flowrate
measurements were no longer valid and could not be used for code comparison. Channel
differential pressure (ǻPHS13) provides an indication of the flow direction in HS13. Similarly,
ǻPHS13-HD5 provides an indication of the flow direction in the outlet feeder of HS13.
Figures 5.44 to 5.46 provide the code comparison to experiment. The DP in Figures 5.44 and
5.45 determines the channel response. It is noted that all code calculations at steady state are
greater than experiment. This is likely due to the inclusion of gravity head in the calculations.
However, all calculations show the correct trend, with the maximum negative DP occurring at
about 50 s. In Figure 5.46, all calculations show the correct general trend, with Argentina,
Republic of Korea, and Romania showing the best agreement with the prediction of the
negative DP at about 40 s.
1.4
RD-14M
Argentina
Canada
1.2 India
1.0
0.8
Void Fraction
0.6
0.4
0.2
0.0
Time (s)
95
1.4
RD-14M
Italy
Korea
1.2 Romania
1.0
0.8
Void Fraction
0.6
0.4
0.2
0.0
Time (s)
1.4
RD-14M
Argentina
1.2 Canada
India
1.0
Void Fraction
0.8
0.6
0.4
0.2
0.0
Time (s)
Fig. 5.38. HS5 Outlet Void Fraction.
96
1.4
RD-14M
Italy
Korea
1.2 Romania
1.0
Void Fraction
0.8
0.6
0.4
0.2
0.0
Time (s)
Fig. 5.39. HS5 Outlet Void Fraction.
RD-14M
1.0 Argentina
Canada
India
0.8
Void Fraction
0.6
0.4
0.2
0.0
Time (s)
Fig. 5.40. HS13 Inlet Void Fraction.
97
1.0
0.8 RD-14M
Italy
Korea
Void Fraction
Romania
0.6
0.4
0.2
0.0
Time (s)
Fig. 5.41. HS13 Inlet Void Fraction.
1.0 RD-14M
Argentina
Canada
Italy
0.8
0.6
Void Fraction
0.4
0.2
0.0
Time (s)
98
1.2
RD-14M
Italy
Korea
Romania
1.0
0.8
Void Fraction
0.6
0.4
0.2
0.0
Time (s)
300
RD-14M
Argentina
Canada
India
200
100
Pressure (kPa)
-100
-200
0 50 100 150 200 250 300 350 400
Time (s)
99
400
RD-14M
Italy
Korea
Romania
300
200
Pressure (kPa)
100
-100
-200
0 50 100 150 200 250 300 350 400
Time (s)
1500
RD-14M
Argentina
Canada
India
1000 Italy
Korea
Romania
500
Pressure (kPa)
-500
-1000
-1500
0 50 100 150 200 250 300 350 400
Time (s)
100
5.13. Confirmatory Variables
The following are confirmatory variables and are used to ensure that the simulations are
performed under the correct conditions.
10.4
RD-14M
Argentina
10.2 Canada
India
Italy
10.0 Korea
Romania
9.8
Pressure (MPa)
9.6
9.4
9.2
9.0
8.8
8.6
0 50 100 150 200 250 300 350 400
Time (s)
Fig. 5.47. Pressurizer Pressure.
101
8
RD-14M
Argentina
7 Canada
India
Italy
Korea
6 Romania
5
Pressure (MPa)
0
0 50 100 150 200 250 300 350 400
Time (s)
Fig. 5.48. Boiler 1 Drum Pressure.
4000
RD-14M
Argentina
Canada
3500 India
Italy
Korea
Romania
3000
2500
Speed (RPM)
2000
1500
1000
500
Time (s)
102
4000
RD-14M
Argentina
Canada
3500 India
Italy
Korea
Romania
3000
2500
Speed (RPM)
2000
1500
1000
500
Time (s)
The following variables are important for this code intercomparison activity. Unfortunately,
there is no experimental data available in test B9401 to be compared to these variables. The
only alternative is to compare the results predicted by each code. These variables are:
This variable is the mass flowrate history at the break location. Figure 5.51 provides the
comparison of code results. All calculations show similar trends, with a peak discharge of
about 50 kg/s, and a long-term discharge (200–350 s) of about 10 kg/s.
The total system power is the sum of the power to each heated section. Figure 5.52 provides
the comparison of code predictions. All calculations show the correct trend. It is noted that
the Italian contribution shows the thermal power to the fluid (from the FES) while the rest
show the power applied to the heaters (an experimental boundary condition).
This is the total mass in the primary system that does not include the mass in the ECC tank
and the ECC system piping, and does not include the mass in the Pressurizer and the
Pressurizer line. Figure 5.53 shows all calculations have a similar mass at steady state, and
most calculations show the correct trend to about 100 s; however, significant differences are
observed after this time.
103
It is noted that the RD-14M loop volume is approximately 1.01 m3, and coupled with the
density distribution in the loop, will determine the mass inventory. Thus differences in the
participant’s prediction at steady state are due to the modelling of the loop volume and the
temperature / density distribution around the loop.
The Italian contribution shows a larger mass inventory in the period from 40 s to 100 s due to
reduced discharge during this time. Again this could be caused by the incorrect calculation of
choked flow in the feeder system. For the period from 100 to 400 s, the Romanian and Korean
calculations show a lower system inventory — due to increased break discharge.
The thermal power across a boiler is the total heat removed from (or added to) the primary
side the boiler. Figures 5.54 and 5.55 provide the comparison of code results. All calculations
show the correct trend.
60
Argentina
Canada
India
50 Italy
Korea
Romania
Mass Flowrate (kg/s)
40
30
20
10
Time (s)
Fig. 5.51. Break Discharge Mass Flowrate.
104
Argentina
Canada
8000 India
Italy
Korea
Romania
Total System Power (kW)
6000
4000
2000
0
0 50 100 150 200 250 300 350 400
Time (s)
1500
Argentina
Canada
India
Italy
Korea
Romania
Mass Inventory (kg)
1000
500
0
0 50 100 150 200 250 300 350 400
Time (s)
Fig. 5.53. Mass Inventory in Primary Loop.
105
6000
Argentina
Canada
India
Italy
4000 Korea
Romania
Thermal Power (kW)
2000
-2000
-4000
0 50 100 150 200 250 300 350 400
Time (s)
Argentina
Canada
4000 India
Italy
Korea
Romania
Thermal Power (kW)
2000
-2000
-4000
Time (s)
Fig. 5.55. Thermal Power Across Boiler 2
106
CHAPTER 6. EFFECT OF DELAYED ECC
RD-14M experiment B9401 was performed in a test facility subject to operating constraints
such as maximum temperature. As a further test of the codes used in this exercise, a more
challenging problem was devised — delaying the emergency core injection (ECC). This will
result in higher FES temperatures, and a resulting refill of the channels at much higher
temperatures. A further comparison of the codes used in this exercise was made with this
problem. It is of course noted that no experimental data exists for this problem, and thus no
comparisons with experiment can be made.
Initial Conditions:
The initial conditions for the problem are exactly the same as the first problem — for
flowrates, pressures, temperatures, power history, etc
Boundary Conditions:
All boundary conditions remain the same as in the first problem (i.e. experimental conditions)
– with the exception of ECC delivery. For this problem ECC injection is specified to start at
300 s (in the experiment it was at 20.6 s). When high-pressure ECC flow is terminated, low-
pressure ECC is started and lasts for a period of 234.5 s.
For this problem a reduced set of calculated results is compared, and displayed in Figures 6.1
to 6.7:
Figure 6.1 shows the comparison of Header 8 to Header 5 DP, and Figure 6.2 shows the
pressure at Header 8. All calculations show similar trends. The Korean calculation shows
somewhat lower flow during bout 400 s to 600 s, and this can be traced to the distribution of
ECC flow during this period.
Figure 6.3 shows ECC flow to Header 8. Note that flow does not start to 300 s. All
calculations show the proper trends. Again, differences between 400 s and 600 s are thought
due to the distribution of ECC flow. Figure 6.4 shows the integrated ECC flow to all headers.
Injection flow is terminated at approximately 600 s. All calculations show the same trends.
Figure 6.5 shows FES temperature at the top pin, middle of HS13. All calculations show the
expected trends:
107
(1) the initial peak at about 25 s.,
(2) the heatup after about 150 s.,
(3) the quenching as ECC is delivered at 300 s, and
(4) a gradual rise at the end of the experiment.
Figure 6.6 shows the break flow, with all calculations producing similar results.
Figure 6.7 shows the Primary System inventory. All calculations show the proper trends of
system emptying until ECC arrives, then an emptying again after ECC is terminated
(~ 600 s.)
6.3. Conclusion
The results show that even with delayed ECC all codes predict that ECC is effective in
cooling the channels, with no predicted asymmetry between channels. All major behaviours
were similar between the codes.
1600
Argentina
1400 Canada
India
Italy
1200 Korea
1000
Pressure (kPa)
800
600
400
200
0
-200
-400
0 200 400 600 800 1000
Time (s)
Fig. 6.1. Header 8 to Header 5 Differential Pressure, Delayed ECC.
108
12
Argentina
Canada
India
10 Italy
Korea
8
Pressure (MPa)
0
0 200 400 600 800 1000
Time (s)
Fig. 6.2. Header 8 Pressure, Delayed ECC.
20
Argentina
Canada
India
Italy
Korea
15
Flowrate (L/s)
10
Time (s)
109
5000
4500
Integral of ECI Flows (L)
4000
3500
3000
2500
2000
1500
1000 Argentina
Canada
500 India
Italy
Korea
0
0 200 400 600 800 1000
Time (s)
Fig. 6.4. Integral of ECI Flows, Delayed ECC.
1000
Argentina
Canada
India
Italy
800 Korea
Temperature ( C )
o
600
400
200
0
0 200 400 600 800 1000
Time (s)
Fig. 6.5. FES Temperature at the Top Pin, Middle HS13, Delayed ECC.
110
60
Argentina
Canada
India
50 Italy
Korea
Mass Flowrate (kg/s)
40
30
20
10
Time (s)
Fig. 6.6. Break Discharge Mass Flowrate, Delayed ECC.
1500
Argentina
Canada
India
Italy
Korea
Mass Inventory (kg)
1000
500
0
0 200 400 600 800 1000
Time (s)
Fig. 6.7. Mass Inventory in Primary Loop, Delayed ECC.
111
CHAPTER 7. SUMMARY/CONCLUSIONS
The activity documented in this report deals with Large Break LOCA analysis in an HWR
system. The reference experiment was performed in the RD-14M test loop located at the
AECL Laboratories in Pinawa, Manitoba. This is the first international code to experiment
exercise of this type in an HWR system and was made possible, within the framework of an
IAEA project, by the availability of experimental data from AECL. The activity required
significant resources from all participants and from the host institution (AECL, Chalk River)
and was carried out in a manner similar to an ISP (International Standard Problem, within the
OECD/CSNI framework).
The main features of the concerned RD-14M experiment, named B9401, are the limited
temperature excursion shortly after the beginning of the LOCA (maximum rod surface
temperature below 600 °C) and the demonstration that the ECC systems can fully recover the
facility a few minutes after the occurrence of the break in one of the four headers. The
geometric complexity of the concerned system represented a challenge for the adopted codes
and the predictions: namely, the ‘figure-of-eight’ of the CANDU systems, the bends and the
orifices inside the feeders and the configuration of the end fittings originated the main
difficulties in the modeling. The transient pressure drops, the location of stagnation point, the
possible occurrence of critical flow in orifices determined the fluid distribution into the loop
and constituted the most difficult phenomena to be predicted.
Six different institutions adopting four different codes and six different idealizations (input
decks) participated in the activity performing the post-test analysis of the B9401 experiment.
It is worth noting that two codes, FIREBIRD and CATHENA have been originated within the
HWR technology and two others, RELAP5/SCDAP and RELAP5/MOD3.2 (with the
‘CANDU option’ used by one participant), have been developed for Light Water Reactors. All
codes are two-fluids six-equation codes, except FIREBIRD that is a three-equation code with
the drift flux capability.
All calculations were capable of achieving a steady state condition consistent with the
experimental data apart from minor deviations that do not significantly affect the
prediction of the transient scenario.
All main phenomena (e.g. break discharge, system depressurization, temperature
excursion and rewet in the heated sections) are qualitatively captured by the
participants. Discrepancies in quantitative terms are observable and explainable but
these do not affect the prediction of the overall system performance.
The application of codes developed outside the HWR technology did not show any
special deficiency in the comparison with the present experimental database. Therefore,
it can be concluded that HWR systems do not need special tools for the analysis of
benchmark experiments of this type.
Notwithstanding the above, the existence of large spatial pressure gradients causes
relevant void distribution effects including movements of liquid fronts that are un-
typical in other systems. This requires special attention in the modeling.
113
In addition, large discrepancies between measured and calculated trends of void fraction
(e.g. Figures 5.36 and 5.37) derived from geometric complexities of some parts of the
loop that cannot be simulated at a proper level of detail by currently available 1-D
codes. However, it was found that such discrepancies were not significant in affecting
the prediction of the overall system performance.
The performed activity is relevant in assessing the capabilities of codes and permitted
the quantification of the amount of discrepancy between measured and calculated
values. This can be used to determine the uncertainty in predicting nuclear power plant
scenarios.
The need for qualified boundary and initial conditions is confirmed from the analysis of
this experiment. An accurate representation of the ECC systems is necessary to correctly
predict the fluid split among the various headers and consequently the fluid distribution
into the system.
The fluid stratification inside heated channels did not play an essential role in this
experiment, although proper measurements were available (at different elevations in
assigned horizontal channels) and codes have the capability to model gravitational
effects inside horizontal channels (however, no proof was achieved of the quality of
these models).
No difference, at the overall system behaviour scale, could be characterized in terms of
quality of prediction between six-equation and three-equation codes. This emphasizes
the conclusion that stratification and non- equilibrium effects were not relevant in this
accident scenario.
The prediction of critical flow at the break and possibly at other locations (e.g. orifices
in feeders or in end fittings) apparently causes deviations betwen measured and
calculated trends of pressure and pressure drops.
The exercise has not been immune from code user effects.
The participants received great benefit from the analysis of this experiment having had the
opportunity of direct contacts with developers of HWR technology and the transfer of
information that is not available in open literature. Moreover, they increased the confidence in
the prediction capabilities by system codes and achieved a better understanding of physical
phenomena related to HWR transient scenarios.
The exercise confirmed the importance of having built and operated complex facilities like
RD-14M and showed, within an international context, the quality level achieved by some
computational tools developed within the HWR technology. In addition, this was an
opportunity for the AECL to assist scientists of HWR owner Countries in performing state of
the art quality accident analyses.
Separate conclusions have been achieved from the analysis of an ‘extreme scenario’ designed
on the basis of the B9401 experiment (i.e. delaying the time of ECC actuation). These
conclusions are discussed in chapter 6 of this report.
114
CHAPTER 8. RECOMMENDATIONS
(1) The database constituted by the codes, the idealizations (input decks including
sketches), the initial and boundary conditions (including the information about the
RD-14M facility), the measurements and the calculation results, should be archived and
will constitute a reference for future generations of codes and of scientists.
(2) Accuracy of the results should be quantified by applying tools aready available for this
purpose to the database, including measurements and calculation.
(3) The experimental database should be used for qualifying HWR nuclear power plant
nodalizations.
(4) It is highly recommended to repeat an activity like the one here documented. Areas of
largest interest for future investigations include simulations of ‘power-pulse’
(i.e. following large break LOCA occurrence owing to positive power feedback) and of
‘high’ rod surface temperature (i.e. 1000°C in order to address code capabilities under
such conditions).
115
REFERENCES
[1] R.S. SWARTZ, “An RD-14M Experiment for the Intercomparison and Validation of
Computer Codes for Thermalhydraulic Safety Analyses of Heavy Water Reactors”,
Atomic Energy of Canada Limited Report, RC-2491, 2000 June.
[2] M.R. LIN, S. PRAWIROSOEHARDJO, “FIREBIRD-III MOD1 Program Description”,
AECL Internal Report, TDAI-373, 1984 November.
[3] B.N. HANNA, 1998, CATHENA: A thermalhydraulic code for CANDU analysis,
Nuclear Engineering and Design (180) 113-131.
[4] J. KESTIN, J.V. SENGERS, B. KAMGAR-PARSI AND J.M.H. LEVELT, 1982,
“Thermophysical Properties of Fluid H2O”, Journal of Physical and Chemical
Reference Data, Vol. 13, No. 1, pp. 175-183.
[5] P.G. HILL, R.V. MACMILLAN AND V. LEE, 1981, “Tables of Thermodynamic
Properties of Heavy Water in S.I. Units”, Atomic Energy of Canada Limited Report,
AECL-7531.
[6] K.E. CARLSON, R.A. RIEMKE, S.Z. ROUHANI, R.W. SHUMWAY, W.L.
WEAVER, AND EDITORS: C. M. ALLISON, C.S. MILLER, N.L. WADE,
“RELAP5/mod3 Code Manual Volume I: Code Structure, System Models, and Solution
Methods”, US NRC NUREG/CR-5535, Washington (DC, USA) June 1990 (see also
Vols. II to V).
[7] F. D’AURIA, G.M. GALASSI, “Code Validation and Uncertainties in System
Thermalhydraulics”, J. Progress in Nuclear Energy, Vol. 33 Nos. 1&2, 1998, pages
175-216.
[8] F. D’AURIA, N. DEBRECIN, G.M. Galassi, “Outline of the Uncertainty Methodology
Based on Accuracy Extrapolation”, J. Nuclear Technology, Vol. 109 No. 1, 1995, pages
21-38.
[9] R. BOVALINI, F. D’AURIA, G.M. GALASSI, “Scaling of Complex Phenomena in
System Thermalhydraulics”, J. Nuclear Science and Engineering, Vol 115, Oct. 1993,
pages 89-111.
[10] F.D’AURIA, G.M. GALASSI, M. LEONARDI, R. GALETTI, “Application of the Fast
Fourier Transform Method to Evaluate the Accuracy of SBLOCA Database”,
NURETH-8 Int. Conf. Kyoto (J), Sept. 30 – Oct. 4, 1997.
[11] R. BOVALINI, F. D’AURIA, “Scaling of the Accuracy of RELAP5/mod2 Code”, J.
Nuclear Engineering and Design, Vol 139, No. 2, 1993, pages 187-204.
[12] F. D’AURIA, G.M. GALASSI, P. VIGNI, A. CALASTRI, “Scaling of Natural
Circulation in PWR Systems”, J. Nuclear Engineering and Design, Vol 132, No. 2,
1992, pages 187-206.
[13] F. D'AURIA, G.M. GALASSI, "Results from the Analysis of RD-14M Test B-9401 by
RELAP5 and Proposal for Quantities to be Considered in the ComparisonRreport”,
University of Pisa Report, DIMNP - NT 432(01), Pisa (I), April 2001. IAEA AGM on
Intercomparison and Validation of Computer codes for Thermalhydraulic Safety
Analyses of Heavy Water Reactors – Vienna (A), May 2-4, 2001.
[14] F. D'AURIA, G.M. GALASSI, "Final Results from the Analysis by RELAP5 Code of the
RD-14M Test B-9401”, University of Pisa Report, DIMNP - NT 471(02), Pisa (I), July
2002, IAEA Advisory Group on Intercomparison and Validation of Computer Codes for
Thermalhydraulic Safety Analyses of Heavy Water Reactors – Vienna (A), Dec. 2-4,
2002.
[15] H.Q. ZHOU, “Intercomparison and Validation of Computer Codes for RD-14M
Experiments B 9401: Variables to be Compared”, RC-2600(Rev. 1), 2002 November.
117