Centro-Matic® Automated Lubrication Systems
System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several
different models may be chosen to control power-operated pumps, depending on the degree of automation and monitoring
required. Your Lincoln representative will assist you in specifying the correct model.
Options range from simple timers to fully-automated system controllers and monitors. Basic timers allow you to set the
interval between lubrication cycles. More sophisticated monitors control the frequency of lubrication, oversee system
performance and can sense lubricant flow to each bearing while showing system status and alarms on a LCD display panel.
Monitors may be interfaced with machine control systems to protect your equipment from harm .
You may customize your installation with air and lubricant filters to prolong system life, pressure gauges for monitoring, shut-
off valves to ease future maintenance and even automated filling systems to utilize bulk lubricant storage.
All of these possibilities, and more, have made Lincoln Automated Lubrication Systems the choice of industry for over 80
years.
Model 84501 Program Timer—Solid State
Designed to control the lubrication cycle frequency of air-operated single-stroke pumps.
Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid
valve (not included) installed in the air line to pump.
Off Time On Time
(Cycle Time) (Pumping Time) Power
Approvals Switch Capacity
Requirement
Min. Max. Min. Max.
1 Min. 120/230 VAC 120 VAC, 5 Amps /
20 Sec. 24 Hrs. 10 Sec. UL, CSA
24 Sec. 50/60 Hz 230 VAC, 1.5 Amps
Built-In Program Ambient Operating
Enclosure
Options Temperature Range
3 Hr.Program Prelube Dimensions-in. / mm
Rating Minimum Maximum
Memory Function Height Width Depth
Yes / No Yes / No NEMA #1 8¹⁄₄ 210 6¹³⁄₁₆ 173 4¹⁵⁄₁₆ 125 0°F -18°C 130°F 54°C
Note:
Refer to Technical Manual for a full explanation of available program options.
Model 84511 Economy Timer for
Single Stroke Pumps
Uses a timing motor, cam and switch to turn pump off and on. NEMA 1 enclosure,
UL and CSA listed. Switch capacity 10 amps non-inductive.
Off Time On Time
(Cycle Time) (Pumping Time) Power
Approvals Switch Capacity
Requirement
Min. Max. Min. Max.
5 Min. 1 Hr. 30 Sec. 90 Sec. 120 VAC, 60Hz UL, CSA 10 Amps
Note: Off-time selectable in 5 minute intervals.
Enclosure
Dimensions - in. / mm
Rating
Height Width Depth
NEMA 1 5 / 127 3¹⁄₄ / 82.5 3¹⁄₂ / 89
41
Centro-Matic® Automated Lubrication Systems
System Controls
Model 84015 Timer—12-24V DC
Solid-state microprocessor-based controller for automated lubrication systems on
mobile equipment or where AC power is not available. Rugged construction with
liquid- and dust-tight enclosure. Includes manual push-button for remote initiation
of a lube cycle.
Off Time** (Cycle Time) Fixed On Time Power Switch
Min. Max. (Pumping Time) Requirement Capacity
2.5 Min. 80 Min. 75 Sec. 10-30 VDC 25 MA* 5 Amps
* Less load. ** Available selections are 2.5, 5, 10, 20, 40 or 80 minutes.
Enclosure Ambient Operating Temperature Range
Dimensions-in. / mm
Rating Minimum Maximum
Height Width Depth
NEMA
5¹⁄₄ / 133 3¹⁄₈ / 79 3 / 76 0°F / -18°C 131°F / 55°C
12
Model 85520 Programmable Controller
Microprocessor-controlled, 120 volt AC unit is fully programmable. Controller has a
wider off-time range than timers and a memory switch to turn pre-lube option on or off.
Switch Capacity
Off Time On Time
Inductive Load
(Cycle Time) (Pumping Time) Power at 120VAC
Requirements
Load Alarm
Min. Max. Min. Max.
Relay Relay
120 VAC
30 Sec. 30 Hours 30 Sec. 300 Sec. 2 Amps 2 Amps
50/60 Hz
Enclosure Ambient Operating Temperature Range
Dimensions-in. / mm
Rating Minimum Maximum
Height Width Depth
NEMA 12 7¹⁄₂ / 191 4¹⁵⁄₁₆ / 125 3¹⁄₂ / 89 -13°F / -18°C 150°F / 55°C
Model 85525 Programmable Controller
Same as Model 85520 except includes pressure switch and mounting brackets.
Model 85535 System Controller—24V DC
Same as Model 85520 except is a 24-volt DC - max “on” time = 2 min.
42
Centro-Matic® Automated Lubrication Systems
System Controls
Model 85530 Lubrication System Controller
Controls lubrication frequency and monitors supply line pressure. The LCD displays
operating status.
Pumping Time
Lube Cycle
Max Before Alarm
Timer Mode Counter Mode Count
Off Time Off Counts Rate* Min. Max.
Min. Max. Min. Max.
30/Sec. @
9,900
1 Minute 9,900 Minutes 1 Count 99,000 Counts 50% Duty 1 Minute
Minutes
Cycle
* Minimum duration of count signal is 33 milliseconds.
Power Requirements Pump,
Ambient Enclosure
(less load) Solenoid,
Temperature
or Alarm Dimensions-in. / mm
Voltage Current Range Rating
Capacity Height Width Depth
120 VAC, 50/60 Hz 85 MA
360 VA 32° to 122°F NEMA 9½ 8¹⁵⁄₁₆ 4¹⁄₈
230 VAC, 50/60 HZ 45 MA
-0° to +50° C 12 241 227 105
24 VDC 250 MA 5 Amps
Note: Model 85530 is CSA/NRTL approved.
Model 85209 Panel Mounted
Pneumatic Control System
Panel mounted units control lubrication frequency and monitor supply line pressure.
Includes Model 85530 Controller (specifications above), Model 69630 Pressure Switch
and solenoid-operated air valve.
Pumping Time
Lube Cycle Connections
Before Alarm
Max
Timer Mode Counter Mode Count
Off Time Off Counts Rate* Min. Max. Air Lube
Min. Max. Min. Max.
9,900 99,000 30/ 1 9,900 ³⁄₈" ³⁄₄"
1 Minute 1 Count
Minutes Counts Sec. Minute Minutes NPTF(F) NPTF(F)
Panel Dimensions
Power Requirements Ambient
External Alarm in. / mm
Temperature
Current Load Capacity
Voltage Range Height Width
(less load)
120 VAC, 60 Hz 32° to 122°F
47 VA 360 VA 12 / 305 18¹⁄₄ / 464
110 VAC, 50 Hz 0° to +50°C
Model 85208
Same as Model 85209 except 220 VAC, 50-60 Hz power.
43
Centro-Matic® Automated Lubrication Systems
System Controls
Model 85500 System Sentry II
The ultimate automated lubrication system controller/monitor now features greater
monitoring accuracy with less sensitivity to lubricant flow rates, feed line length, or
bearing back pressure. System Sentry II is always on the job, making sure that every
lube point is lubricated when it’s supposed to be.
• Solid-state controller with LCD status display and 16-button keypad for system
programming
• Controls up to two pumps with as many as two lube zones per pump
• Fully programmable monitoring and alarm functions
• Be set up to monitor every lube point for lubricant flow during each lubrication event
• Easy to understand prompts reported by simple English language messages in real
time
Some functions require optional accessories. Use a maximum of 48 sensors
and three accessory Sensor Boards (order separately—16 sensors per board) to
monitor lube points.
Pumping Time
Lube Cycle
Max Before Alarm
Net
Timer Mode Counter Mode Count
Wt.
Off Time Off Counts Rate* Min Max
Min. Max. Min. Max.
30/Sec. @
9,900 99,000 99 18 lbs.
1 Second 1 Count 50% Duty 1 Second
Minutes Counts Minutes 8.1 kg
Cycle
* Minimum duration of count signal is 33 milliseconds.
Power Requirements Pump,
Ambient Enclosure
(less load) Solenoid,
Temperature
or Alarm Dimensions-in. / mm
Voltage Current Range Rating
Capacity Height Width Depth
120 VAC, 50/60 Hz 250 MA*
360 VA 32° to 122°F NEMA
230 VAC, 50/60 HZ 125 MA* 11/241 14/227 4⁷⁄₈/105
0° to 50° C 12
24 VDC 600 MA* 5 Amps
Note:
Model 85500 is CSA/NRTL approved.
* No external load, no sensors.
44
Centro-Matic® Automated Lubrication Systems
System Controls
Model 247333 Pressure Transducer
Pressure Transducer signals actual system pressure via LCD display of System
Sentry II. Comes with 72 inch (1.8m) shielded 24-gauge connecting wire. Maximum
length of wire between transducer and monitor is 30 (9.1m) feet.
Pressure Ambient Voltage
Range Accuracy Proof Input Offset Enclosure
Connection Temp. Output
NEMA 4X
7500
0 to 10 to Rating
psig ¹⁄₄" NPT Male -20° to 180° F
4000 psi ±1% 30 1-6 VDC 1 VDC 300 Series
517 Thread -29° to 82° C
276 bar VDC Stainless
bar
Steel
Model 250365 Sensor Board
Plug-in accessory board used with Model 85500 that allows the attachment of up to
16 lube flow sensors. (Model 85500 comes without boards installed and can hold up
to a total of three.)
Sensor Assemblies
Sensor assemblies consist of a check body and lube sensor with attached 30' cable.
Cables are epoxy potted into the sensors for a watertight seal. Sensors have a ⅜"
pipe thread for conduit connection and a Viton® O-ring seal. Check bodies terminate
in a ⅛" NPTF male thread for attachment to a bearing or other lubricant inlet.
Maximum working pressure 6,000 psi (414 bar). Maximum wire run from sensor to
monitor is 500 feet (152m).
Lubricant Min. Interval
Min. Flow Inlet/
Model Description Construction Temp. Between Lube
Per Event Outlet
Range Flow Event
Straight
250400 Sensor .004 cu.
Brass Sensor
Assembly in./.066 cc @
& Plated Steel
32°F /0°C to
90° Sensor Check Body
250490 125°F/52°C
Assembly 32° to 145° F
1/8" 30 Seconds
Straight 0° to 63° C
250500 Sensor 316 Stainless .008 in³/.131cc
Assembly Steel Sensor & @ 126°F/53°C
90° Sensor Check Body to 145°F/63°C)
250590
Assembly
Model 243100 Sensor Wire
100 foot (30.5 meters) coil of two conductor 22-gauge wire for connecting sensors to
monitor. Maximum length of wire between sensor and monitor is 500 feet (152 meters).
45
Centro-Matic® Automated Lubrication Systems
System Controls
Use This Guide to Select Accessories for
Model 85500 System Sentry II
Pressure Pressure Sensor Sensor Wire
Sensors
Function Switch Transducer Board #243100 (100')
Note 2
#69630 #247333 #250365 Note 3
Lube Controller
1 Pump, 1 Zone Optional 1 Optional 1 — — —
Note 1
Lube Controller, Required
1 Pump, 1 per Zone Required 1 — — — —
Up to 3 Zones (3Max.)
Lube Controller,
Required 2
2 Pumps, 1 Zone No — — —
(1 per Pump)
Per Pump
Lube Controller, Required
Required 2
2 Pumps, Up to 2 1 per Zone — — —
1 per Pump)
Zones Per Pump (4Max.)
Lube Point Required Required Required
Monitoring — — 1 per each 1 per Quantity
≤ 48 Points 16 Sensors Lube Point As Needed
Note 1: Controller may be operated without a pressure switch or pressure transducer but will not be
able to monitor and alarm for lube system pressure failures.
Note 2: Sensors include 30' (9.1m) cable pigtail. Select brass/plated steel or stainless steel sensors
in straight or 90° configuration as required.
Note 3: Maximum distance between monitor and sensor is 500' (152 meters).
46
Centro-Matic® Automated Lubrication Systems
System Controls
Electric Solenoid-Operated Air Valves
Electrical Characteristics
Air Ambient Max.
Model Type Inrush Holding Inlet/ Temperature Cv Pressure Conduit
Power Factor Connection
Current Current Outlet Range psi / bar
Requirements
Amps Amps
110 VAC, 50 Hz
350244 120 VAC, 60 Hz .11 .07
8.4 VA 0° to 120°F
4-Way 1.2
220 VAC, 50 Hz -18° to 49°C
350245 240 VAC, 60 Hz .055 .035
8.4 VA ¼
½" NPS(F)
110 VAC, 50 Hz NPT(F)
350241 120 VAC, 60 Hz .11 .07
8.4 VA
220 VAC, 50 Hz
350242 3-Way 240 VAC, 60 Hz .055 .035 .18
150 / 10.3
8.4 VA
0° to 140°F
350282 12 VDC 6 Watts ⅛" -18° to 60°C
N/A N/A N/A
350283 24 VDC 6 Watts NPT(F)
120V, 60 Hz 12 ⅜"
68586 2-Way .2 .1 2.4 ½" NPT(F)
VA NPT(F)
24 VDC 8.5 ¼"
274398 N/A N/A .5 N/A
Watts NPT(F)
3-Way 110 VAC, 50 Hz
⅜" 0° to 120°F
244727 120 VAC, 60 Hz .12 .09 4.4 ½" NPT(F)
NPT(F) -18° to 49°C
11 VA
Model 249605 Sealed Cycle Timer
Sealed timer attaches to Lincoln 16:1 Hydraulic Pumps and generates timed pulse signal to
control pump reciprocating cycle rate.
Power Cycle Rate/Minute
Requirement Min. Max
24 VDC 6 60
47
Centro-Matic® Automated Lubrication Systems
System Controls
End-of-Line Monitors
Designed to detect system pressure utilizing normally open or normally closed switch.
Operating Range - Dimensions -
Switch psig / bar Lube in / mm Conduit
Model
Rating Inlet Connection
Min. Max Height Width
83898 125, 250 1200 / 83 2500 / 172
¹⁄₄"
480 VAC, 5³⁄₄ / 146 2¹⁄₄ / 57 ¹⁄₂" NPSM
83899 700 / 48 1150 / 79 NPTF(F)
15 Amps
Model 83354 Signal Monitor
Designed to provide visual and audible indication of system operation and failure.
Utilizes signal from system controller. Includes Model 69606 Alarm Horn mounted on
enclosure door.
Indicator Lamps Dimensions - in / mm
Power Audible
Requirement Power Lube System Alarm
Height Width Depth
On System On Failure
115 VAC 69606 Horn
Green Amber Red 10 / 254 8 / 203 6 / 152
50/60 Hz 35 VA (Included)
Note: Lamps and horn are U.L. listed.
Model 69630 Pressure Switch
Senses supply line pressure rise/fall to signal system operation to controller or
system alarm.
Adjustable Range - psig
Switch Capacity Connections
/ bar
Type
Decreasing Increasing
AC DC Lube Electrical
Min Max Min. Max.
10 Amps at 15Amps@6VDC ²⁷⁄₃₂" hole for
Single 250 / 2775 / 280 / 3000 ¹⁄₄"
125, 250 or 5Amps@24VDC .03 ¹⁄₂" conduit
Contact 17 191 19 / 207 NPT(F)
480 VDC Amps@ 250 VDC connector
Note: Pressure switch has a NEMA 3 housing and UL listed switching elements.
48