HC 2500

The HC2500 Service Manual provides detailed information on hardware versions, user menus, and extended menu functions for the device. It outlines two hardware versions, their specifications, and instructions for accessing and navigating the user and extended menus. Additionally, it includes default values, testing procedures, and troubleshooting tips for sensors and connections.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
101 views9 pages

HC 2500

The HC2500 Service Manual provides detailed information on hardware versions, user menus, and extended menu functions for the device. It outlines two hardware versions, their specifications, and instructions for accessing and navigating the user and extended menus. Additionally, it includes default values, testing procedures, and troubleshooting tips for sensors and connections.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

Service Manual

HC2500
679061 - rev. 4
GB – 08.2007

Table of contents:
Hardware versions
User menu
Extended menu of SW 1.52
Scanbox
Default values
Test

Page 1 of 9 1
Hardware versions
There are 2 versions. Display

First version
From 1999 to July 2003, it includes a
junction box called Scanbox.
Control box has a 20 pin connector.
Software version of the screen is up to
1.30 and it will not run on the second
Scanbox
version.

Second version
From August 2003 and on, the screen
does not need a Scanbox.
The control box has a 39 pin connector.
Software version of the screen is 1.52 and
up and it will also run on the first version.

Picture shows the harness block with


Speed, Flow and Switch connections and
the power supply cable when used as a
HM 1500 on a BK control unit.

Page 2 of 9 2
User menu
User menu

Extended menu of SW 1.52


To access the extended menu, start the
computer.
Press both arrow keys at the same time
until the menu changes.
“Language” will start as the first item.

Extended menu is written in English only.

Page key
• To enter the menus
• To page into the menu

Arrow keys
• To find the desired menu
• To toggle between the choices
• To alter a parameter

Accept or Enter key
• To accept the shown setting

Page 3 of 9 3
• To exit the menu

NOTE: Re-start the system after leaving


the extended menu.

Menu Function [ choices ]


Normal setting and sets shown in italics
[ Language ] To select language.
[ GB, DK, F, E, D, Cz, SF, NL, I, S ]
[ Unit ] To set unit of measurement.
[ Metric, USA ]
[ ON/OFF valve ] To select type of control unit.
[ Present, Not present ]

For EC: Present


For BK, EVC, EFC & SC: Not present
[ Pressure system ] To select pressure system.
[ Equalisation, No equalisation ]

For EC & EVC: Equalisation


For EFC: No equalisation
[ Control box] To indicate control box connected.
[Lunch box, Spray box, Not connected ]

Not connected: BK
Lunch box: Rectangular box with 20 pin
connector.

Spray box: Wave shaped box with 39 pin


connector.
[ Tank volume max ] Pre-set tank volume indicated at start-up.
Value is the maximum tanks contents
value.
[ Analog adjust ] To calibrate the optional transducer.
Press the page key to go through the 3
items.
[ max., min., offset in mA ]

For pressure sensor, remove it from the


housing to ensure 0 bar.
It should show 0.0 bar +/- 0.1 bar
[ Analog unit text ] To choose the unit of measurement.
Press the page key to go through the
items.
[ Bar, PSI, deg C, deg F, % R.H ]
[ Regulation con. ] For the sensitivity of the pressure
regulation valve.

Page 4 of 9 4
It is a percentage and minus values are
possible.
The higher value makes the pressure
regulation valve more sensitive.
Too high a value will cause oscillation and
excessive wear on the valve.

For EC & EVC: 30%


For EFC: 20%
[ Min. press. cycle ] Sets the minimum power supply to move
the pressure regulation.
Increase the value until the pressure
regulation valve just starts to turn.
Use “page” key to toggle between no
regulation, () increase pressure () and
decrease pressure ().
Use “arrow” keys to raise or lower
percentage until the value begins to turn.

Normal value for new valve: 10%


[ Change SW ver. ] To permit change or update of software.
PIN code needed.
Note serial number and contact HARDI.
[ Master reset ] To reset. PIN code needed.
Note serial number and contact HARDI.
[ Area totals ] To see total area covered and volume
sprayed.
[ Scanbox ] To change screen contrast, press arrow up
or arrow down keys.

Factory menu for visual indication whilst


testing for version from 1.09 and on.
It is possible to test or readout signals for:
Line 1
• Pressure up / down
• Working hour
• Main valve ON/OFF
• mAmp for pressure transducer if fitted
Line 2
• Number of sections connected &
number of active sections
• Flow transducer
• Speed transducer
• PTO sensor
• Areameter switch
• Extra 2, 3 & 4

Page 5 of 9 5
Scanbox

Page 6 of 9 6
Default values
Text For HC 2500 For HM 1500*
[ Language ] GB GB
[ Unit ] Metric Metric
[ ON/OFF valve ] Present Present
[ Pressure system ] Equalisation Equalisation
[ Control box ] Lunch box Not connected
[ Tank size ] 2000 l 2000 l
[ Analog adjustment ] max. 10 max. 10
min. 0 min. 0
offset 0 mA offset 0 mA
[ Analog unit text ] Bar Bar
[ Regulation con. ] 0% 0%
[ Duty cycle ] 10% not relevant
[ Flow PPU ] 120.0 120.0
[ Speed UPP ] 1.0000 1.0000
HM 1500* For BK control unit with Spray (control)
box for boom sections set:
[ Control box ] to [Spray box ]

For EVC control unit set:


[ ON/OFF valve ] to [ Not present ]
[ Control box ] to [Spray box ]

Page 7 of 9 7
Test
A service tool can easily be made.
It consists of;
a cable joiner strip
plugs
sockets

The plugs and sockets are connected via


the cable joiner.
This now allows easy access with multi-
meter probes to the metallic screws when
measuring sensor voltage.

Another service tool is a pulse generator


that can be used to simulate speed or flow.

Reference number is 732182.

Extra connectors have been added to


cater for older systems.

Flow sensor
Hall element type
Check all magnets are present.
Check spindle bushes are not worn.

Brown to 12 volt
Black to negative
Blue to multimeter positive
Multimeter negative to negative

Normal readout:
High is 8.0 volt +/- 1 volt (Diode on)
Low is 0.3 volt +/- 0.1 volt

Speed sensor
Brown to 12 volt
Black to negative
Blue to multimeter positive
Multimeter negative to negative

Inductive type
Sensor to metal distance = 3 to 5 mm
Normal readout:
High is 12.0 volt +/- 1 volt

Page 8 of 9 8
Low is 1.4 volt +/- 0.2 volt (Diode on)

Hall Element type


Sensor to magnet distance = 3 to 7 mm
Normal readout:
High is 7.0 volt +/- 1 volt (no magnet)
Low is 0.3 volt +/- 0.1 volt

Date / Revision Section / Subject Pages Written By


01-10-2007 / 04 General update of whole document AF

Page 9 of 9 9