RISH EINE NX
With Touch Key
Measure Control Record Analyze
Page 1/4 Rev : E 06/23
Data Sheet
RISH EINE NX
RISH VA Meter
Application:
The Digital meter PROGRAMMABLE RISH Eine NX have On site programmable PT parameters:(For volt DPM)
been designed for industrial application ,which frequently Potential Transformer (PT) primary and secondary is
require precise and on-site adjustment of the display range. It programmable on site through front panel keys.
can be used in industrial automation and for laboratory uses. PT Primary value ranging from 57.5 VLN to 900 kVLN.
PT Secondary value ranging from 57.5 VLN to 480 VLN.
Salient Features:
On site programmable CT parameters:(For Ammeter)
· True RMS measurement. Current Transformer (CT) primary and secondary is
· Attractive look with two touch keys. programmable on site through front panel keys.
· 3 digit or 4 digit ultra bright 7 Segment LED display. CT Primary value ranging from 1A to 9999A.
· Fast & Easy Installation on panel with click fit arrangement CT Secondary value ranging from 1A/5A.
Product Features: Auxiliary supply:
Display parameters: Higher Auxiliary power supply with voltage range 60V-300V AC/DC.
Voltage VLN or Current.
Enclosure Protection for dust and water:
True RMS Measurement: Conforms to IP 50 (for front face) & IP 20 (for back) & as
per IEC60529.
The instrument measures distorted waveform upto 15th
harmonic.
EMC Compatibilty:
Compliance to IEC61326.
Ultra bright LED Display:
Voltage DPM has 3 digit 1 line seven segment LED display.
Ammeter/Current DPM has 4 digit 1 line seven segment LED
display.
Front panel keys:
Two keys are useful for easy setup navigation and changing setup
parameters.
Measure Control Record Analyze
Page 2/4 Rev : E 06/23
Data Sheet
RISH EINE NX
Installation Technical Specifications:
Operating Measuring Ranges:
Voltage Range 10V ...... 519V
Current Range For 1A(15mA -1.2A) & For 5A(55mA- 6A)
Frequency 45…65 Hz.
Easy Clip - in
Input Voltage: (for Volt DPM)
mounting
Full Scale Input voltage (AC RMS)(FS) 480 VLN.
Max continuous input voltage 519 VLN. (OL >1.083 X PT Primary).
Input voltage burden <0.3 VA approx at 230V.
Input Current: (for Ammeter)
Input current. 1A or 5A.
Max continuous input current 120% of CT Primary.(OL >1.21 X CT Primary).
Input current burden <0.3 VA approx.
Auxiliary Supply:
Higher AC-DC External Aux. 60-300V AC/DC.
96 mm
27 mm Frequency range 45 to 65 Hz.
VA burden 5 VA Approx.
Overload Withstand:
Voltage 600VLN for 1 second, repeated
10 times at 10 second intervals.
96mm
Display Area
Current 2 x 5A for 1 second, repeated
5 times at 5 second intervals.
Reference conditions for Accuracy:
Reference temperature 23°C ±2°C.
6 mm
Input waveform Sinusoidal (distortion factor 0.005).
35 mm
Input frequency 50 or 60 Hz ±2%.
Auxiliary supply voltage Nominal Value ±1%.
Auxiliary supply frequency Nominal Value ±1%.
Display update rate:
Response time to step input Less than 1 second.
Electrical Connection: Accuracy:
Voltage ± 1.0 % of FS (optional ± 0.5 %)
Current ± 1.0 % of 5A (optional ± 0.5 %)
1 2 13 14
Influence of Variations:
L N
Temperature coefficient : 0.03 % /°C for Voltage.
+ -
AUX
(for range of use (0°C to 55°C) 0.05 % /°C for Current.
SUPPLY
L
L1 O
A Applicable Standards:
N
D EMC IEC 61326-1 (Table-2).
Connection For Voltage DPM Safety IEC 61010-1-2018,Permanently connected use.
IP for water & dust IEC 60529.
Environmental:
Operating temperature 0°C to +55°C.
Storage temperature -25°C to +70°C.
1 2 13 14 Relative humidity 0... 90% non condensing.
Warm up time Minimum 3 minute.
L N
+ - L Shock Half sine wave, Peak acceleration
AUX O
SUPPLY 30gn (300 m/s^2),
L1 A
D Vibration 10... 55 Hz, 0.15mm amplitude.
N
Enclosure:
Connection For Ammeter DPM
Front IP 50
Back IP 20
Dimensions:
Housing dimensions 96 x 96 x 40 mm.
Panel cut-out 92.8 x 92.8 mm.
Safety:
Pollution degree 2
Installation category III
High Voltage Test 2 kV AC, 50Hz for 1 minute between
Measure Control Record Analyze
Page 3/4 Rev : E 06/23
Ordering Information:
Product Code : ED99 - G - 1 - X - XX - H - 5 - 0 - 0 - 0 - 0000
V : AC Voltage DPM
A : AC Ammeter DPM
8C :Input type-57.5-480VLN(Programmable)
8D : Input type-1/5A (Programmable)
5 : Accuracy - 0.5
1 : Accuracy - 1
Order Code Example:
ED99-G1V8AH50000000.
ED99- 96x96, 1-Phase, Voltage DPM, 57.5- 480 VLN,60-300 VAC/DC,Class 0.5,standard IP50.
Measure Control Record Analyze
Page 4/4 Rev : E 06/23
Measure Control Record Analyze
RISHABH INSTRUMENTS LTD.
Domestic (India): +91 253 2202028/99 | marketing@rishabh.co.in
International: +91 253 2202004/06/08/99 | global@rishabh.co.in
www.rishabh.co.in
RISH EINE NX
With Touch Key
Measure Control Record Analyze
Page 1/5 Rev : E 06/23
Data Sheet
RISH EINE NX
RISH VA Meter
Application: Display Autoscroll:
Display auto scroll enables user to see all parameters without key
The Digital meter PROGRAMMABLE RISH Eine NX have operation.
been designed for industrial application ,which frequently
On site selection of auto/manual scrolling.
require precise and on-site adjustment of the display range. It
can be used in industrial automation and for laboratory uses.
Communication:
Optional Isolated multi baud rate RS485 ( MODBUS )
Salient Features:
output for remote viewing, configuration and external
· True RMS measurement.
logging.
· Attractive look with Two touch keys.
· User Selectable 3Ph4Wire,3Ph3Wire and single phase On site programmable PT parameters:(For volt DPM)
network Potential Transformer (PT) primary and secondary is
· 4 digits ultra bright LED display. programmable on site through front panel keys and MODBUS.
· Fast & Easy Installation on panel with Click fit arrangement. PT Primary value ranging from 100 VLL to 999 kVLL.
· Optional RS485 ( MODBUS ) for remote settings and PT Secondary value ranging from 100 VLL to 500 VLL.
monitoring.
· Relay output. On site programmable CT parameters:(For Ammeter)
Current Transformer (CT) primary and secondary is
Product Features: programmable on site through front panel keys and MODBUS.
CT Primary value ranging from 1A to 9999A.
Display parameters:
CT Secondary value ranging from 1A/5A.
Voltage VLN, Voltage Line-Line or Line current or System
Voltage or Current.
Auxiliary supply:
True RMS Measurement:
Higher Auxiliary power supply with voltage range 60V-300V AC/DC
The instrument measures distorted waveform upto 15th
.
harmonic.
Enclosure Protection for dust and water:
1 line 4 digits LED display: Conforms to IP 50 (for front face) & IP 20 (for back) & as
1 Line 4 digits seven segment LED display for simultaneous per IEC60529.
reading of voltage or current.
Front panel keys: EMC Compatibilty:
Using two key, it is possible to go to desired parameter Compliance to IEC61326.
on screen instantly. Two keys are also useful for easy setup
navigation and changing setup parameters.
Potential Free Relay Contact (Optional):
User selectable relay output. Relay output can be configured as
Limit (Alarm) switch or Timer output to operate relay in cyclic
manner.
Measure Control Record Analyze
Page 2/5 Rev : E 06/23
Data Sheet
RISH EINE NX
Technical Specifications:
Installation Operating Measuring Ranges:
Voltage Range 11 -- 346VLN. (19 –-- 600VLL)
Current Range For 1A (30mA-1.2A) & For 5A(55mA-6A)
Frequency 40…70 Hz.
Input Voltage: (for Volt DPM)
Click fit
mounting Nominal Input voltage (AC RMS) 57.7-288VLN. (100V..500VLL)
Max continuous input voltage 120% of Nominal volt of Primary .(OL >1.21 x PTP )
Input voltage burden 0.3 VA approx per Phase at 230VAC
Input Current: (for Ammeter)
Nominal Input current 1A / 5A per Phase.
Max continuous input current 120% of Nominal current of Primary.(OL >1.21 x CTP )
Input current burden 0.3 VA approx per Phase.
96 mm Auxiliary Supply:
27 mm Higher AC-DC External Aux. 60-300V AC/DC.
Frequency range 45 to 65 Hz.
VA burden 5 VA Approx.
Overload Withstand:
96mm
Display Area Voltage 620 VLL for 1 second, repeated
10 times at 10 second intervals.
Current 2 x 5A value for 1 second, repeated
5 times at 5 second intervals.
6 mm Reference conditions for Accuracy:
35 mm Reference temperature 23°C ±2°C.
Input waveform Sinusoidal (distortion factor 0.005).
Input frequency 50 or 60 Hz ±2%.
Electrical Connection: Auxiliary supply voltage Nominal Value ±1%.
For Voltage DPM Auxiliary supply frequency Nominal Value ±1%.
Display update rate:
1 2 3 4 13 14 Response time to step input Less than 1 second.
Accuracy:
L N
+ - Voltage ± 1.0 % (As Per Nominal Voltage Set) (opt. ± 0.5)
AUX
SUPPLY Current ± 1.0 % of 1A/5A (opt. ± 0.5)
L1 L
O
Influence of Variations:
L2
A Temperature coefficient : 0.025 % /°C for Voltage.
L3
N D (for range of use (0°C to 55°C) 0.05 % /°C for Current.
Applicable Standards:
Connection For EMC IEC 61326 -1(Table-2).
3PH - 4 Wire Network Safety IEC 61010-1-2018,Permanently connected use.
IP for water & dust IEC 60529.
1 2 3 13 14 Interfaces: (Optional)
Relay 250 VAC, 5 A AC / 30VDC, 5A DC
L N MODBUS Rs485, max.1200m
+ -
AUX
Baud rate : 4.8, 9.6,19.2, 38.4, 57.6 kBPS
SUPPLY Environmental:
Operating temperature 0°C to +55°C.
L1 L
Storage temperature -25°C to +70°C.
O
L2 Relative humidity 0... 90% non condensing.
A
L3 Warm up time Minimum 3 minute.
D
Connection For Shock Half sine wave, Peak acceleration
3PH - 3 Wire Network 30gn (300 m/s^2),
Vibration 10... 55 Hz, 0.15mm amplitude.
Enclosure:
1 4 13 14 Front IP 50
Back IP 20
L N
+ -
AUX
Dimensions :
SUPPLY
L Housing dimensions 96 x 96 x 40 mm.
L1 O
A Panel cut-out 92.8 x 92.8 mm.
N
D Safety:
Connection For Pollution degree 2
Installation category III
1PH -2 Wire Network High Voltage Test 2kV AC, 50Hz for 1 minute between
aux. and measuring input.
Measure Control Record Analyze
Page 3/5 Rev : E 06/23
Data Sheet
For Current DPM
RISH EINE NX
1 2 3 4 5 6 13 14
Weight 200gm Approx.
L N
+ -
AUX
SUPPLY L
L1
O
L2 A
L3 D
Electrical Parameters:
N
Connection For Sr No. Parameters 3 Phase 4 Wire 3 Phase 3 Wire 1 Phase 2 Wire
3PH - 4 Wire Network
Voltage Ammeter Voltage Ammeter Voltage Ammeter
1 2 5 6 13 14 1 System Voltage ü ü ü
L N 2 System Current ü ü ü
+ -
AUX 3 Volts L1–N ü ü
SUPPLY L
L1 4 Volts L2–N ü
O
L2 A 5 Volts L3–N ü
L3 D 6 Volts L1-2 ü
ü
Connection For 7 Volts L2-3 ü
ü
3PH - 3 Wire Network
8 Volts L3-1 ü ü
1 2 13 14 9 Current L1 ü ü ü
L N
10 Current L2 ü ü
+
AUX
-
L 11 Current L3 ü ü
SUPPLY O ü ü ü ü ü
L1 A
13 Timer No. of cycles ü
N D 14 Relay Limit ü ü ü ü ü ü
Connection For
1PH - 2 Wire Network
Ordering Information:
Product Code : ED99 - G - 3 - X - XX - H - 5 - 0 - 1 - X - 0000
V : AC Voltage DPM
A : AC Ammeter DPM
8C :Input type-100-500VLL(Programmable)
8D : Input type-1/5A (Programmable)
5 : Accuracy - 0.5
1 : Accuracy - 1
Z : Basic
R : Advanced (1-Relay Output and Modbus)
Order Code Example:
ED99-G3V8CH500R0000.
ED99- 96x96, 3-Phase, Voltage DPM, 100 - 500 VLL,60-300 VAC/DC,Class 0.5,standard IP50,Advanced,
Measure Control Record Analyze
Page 4/5 Rev : E 06/23
Measure Control Record Analyze
Page 5/5 Rev : E 06/23