219 East Main Street
Mechanicsburg, PA, USA 17055
Toll Free: 866-EESIFLO
Fax: (717) 697-2122
FLUXUS F601 Series
Dual Channel, Dual Mode Ultrasonic Flowmeter
FlowRental.com has successfully rented the FLUXUS F601 to hundreds of unique clients, and it
has never failed to produce unequaled results. Our clients have measured pipes from ¼ inch
all the way up to 200 inches in diameter. When you absolutely must make flow measurements
under the most severe conditions, the FLUXUS F601 is your only solution. Following are its
specifications:
General Process inputs Galvanically isolated from main electronics
Measuring principle Ultrasonic time difference Temperature PT 100, four-wire circuit, measuring range - 58...750 ºF
correlation principle and Doppler Current 0...20mA; Ri=50 ohm
Flow velocity range 0.01...25m/s Voltage 0...1 V; Ri = 1 Megohm
Resolution 0.025 cm/s
Repeatability 0.15 % of measured value Process Outputs Galvanically isolated from main electronics
± 0.015 m/s Current 0/4... 20 mA; passive (Uext< 24 V) or active (Rext < 500
Accuracy Volume flow ohm)
± 1 ... 3 % of measured value Voltage 0...1 V or 0...10V, Ri=500 ohm
depending on application, Frequency 0...1 kHz or 0 10 kHz; (OC)
±0.5 % of measured value with process calibration Digital (pulse, status) Totalizer value 0.01 1000 / unit; width 80...1000 ms; (OC/
Flow velocity ± 0.5 % of measured value Reed) Reed = Reed-NO contact (300 V /0.5 A)
Turn down ratio 1/200 OC = Open-Collector
Gaseous and solid Clamp-on sensors
content of medium < 10 % of volume Type M2N, M2E
Rated diameter range 4 inch to 256 inch
Flow transmitter Dimensions 1.9 x 1.18 x 1.34 inch
Enclosure Portable Material Stainless steel
Degree of protection IP 54 according EN 60529 Temperature range Type M2N: -22 ... 266 ºF; TypeM2E: -22 ... 392 ºF, for
Operating temperature 14...140 ºF short periods up to 572 ºF
Housing material Aluminum, powder coated Degree of protection IP 65 acc. EN 60529, IP 68 optional
Flow channels 2
Power supply Internal rechargeable battery, 6 V/4 Ah or external Type Q3N, Q3E
power supply 9...15V DC Rated diameter range 1 inch to 16 inch
Operating time >14 h with fully charged battery Dimensions 1.7 x 0.71 x 0.87 inch
Display 2 x 16 digit LCD, dot matrix, backlit Material Stainless steel
Dimensions H 118 x W 276 x D 310mm (with handle) Temperature range Type Q3N: -22...266 ºF; Type Q3E: -22...392 ºF, for short
Power consumption < 2.5 W in measurement mode periods up to 572 ºF
Signal damping 0...60 s, configurable Degree of protection IP 65 acc. EN 60529, IP 68 optional
Response time 1 s, 70 ms optional
Measuring cycle 100 ... 1000 Hz, single channel Special Clamp-on sensors
Calculation functions Average/difference/sum Type S2N ¼ inch to 1 ½ inch, -22...266 ºF
Type K2N 4 inch to 256 inch, -22...266 ºF
Quantity and units of measurement
Volumetric flow rate m³/h, m³/min, m³/s, l/in, l/min, l/s, USgph, bls/d Wall thickness measurement
Flow velocity m/s, inch/s Measuring range : 0.04 to 7.9 inches
Mass flow rate g/s, t/h, kg/in, kg/min Resolution 0.0004 inches
Volume m³, l, gal (gallons) Linearity 0.004 inches
Mass g, kg, t Temperature range Standard version -4 ... 140 °F; High temperature
Heat flow W. kW, MW (only with heat quantity option) version 32 ... 398 °F, for short periods up to 540 °F
Heat quantity J. kJ, MJ (only with heat quantity option)
Accessories
-External power supply 110 V, 60Hz/12 V, 1.2 A; IP 30
Internal data logger -Cable extension 15 ft, 33 ft
Storage capacity approx.100,000 measuring values -Sensor positioning mounts
All measured and totalized -External printer, ink jet 192 dpi
Logging data values, parameter sets
Software Data
Communication Functionality Downloading of measured values/parameter se and export
Serial interface RS 232 Operating systems All Windows™ Operating Systems
Data Instantaneous measured value,
parameter set, logged data