0% found this document useful (0 votes)
10 views6 pages

LC1D95M7: Product Data Sheet

The document provides a detailed product data sheet for the TeSys D contactor model LC1D95M7, which is designed for motor control applications with a rated operational current of 95 A and a control circuit voltage of 220 V AC. It includes specifications such as operational voltage, motor power ratings, mechanical and electrical durability, environmental standards, and packaging information. Additionally, it outlines compliance with various safety and environmental regulations, along with warranty details.

Uploaded by

nguyenduylongk08
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
10 views6 pages

LC1D95M7: Product Data Sheet

The document provides a detailed product data sheet for the TeSys D contactor model LC1D95M7, which is designed for motor control applications with a rated operational current of 95 A and a control circuit voltage of 220 V AC. It includes specifications such as operational voltage, motor power ratings, mechanical and electrical durability, environmental standards, and packaging information. Additionally, it outlines compliance with various safety and environmental regulations, along with warranty details.

Uploaded by

nguyenduylongk08
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Product data sheet LC1D95M7

Characteristics TeSys D contactor - 3P(3 NO) - AC-3 - <= 440


V 95 A - 220 V AC 50/60 Hz coil

Main
Range TeSys
Range of product TeSys Deca
Product or component Contactor
type
Device short name LC1D
Contactor application Motor control
Resistive load
Utilisation category AC-3
AC-3e
AC-4
AC-1
Poles description 3P

It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
[Ue] rated operational Power circuit: <= 690 V AC 25...400 Hz
voltage
[Ie] rated operational 95 A (at <60 °C) at <= 440 V AC-3 for power circuit
current 125 A (at <60 °C) at <= 690 V AC-1 for power circuit
95 A (at <60 °C) at <= 440 V AC-3e for power circuit
[Uc] control circuit 220 V AC 50/60 Hz
voltage

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.

Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Complementary
Motor power kW 25 KW at 220...230 V AC 50 Hz (AC-3)
45 KW at 380...400 V AC 50 Hz (AC-3)
45 KW at 415...440 V AC 50 Hz (AC-3)
55 KW at 500 V AC 50 Hz (AC-3)
45 KW at 660...690 V AC 50 Hz (AC-3)
15 KW at 400 V AC 50 Hz (AC-4)
25 KW at 220...230 V AC 50 Hz (AC-3e)
45 KW at 380...400 V AC 50 Hz (AC-3e)
45 KW at 415...440 V AC 50 Hz (AC-3e)
55 KW at 500 V AC 50 Hz (AC-3e)
45 kW at 660...690 V AC 50 Hz (AC-3e)
Motor power hp 7.5 Hp at 120 V AC 60 Hz for 1 phase motors
15 Hp at 230/240 V AC 60 Hz for 1 phase motors
30 Hp at 200/208 V AC 60 Hz for 3 phases motors
30 Hp at 230/240 V AC 60 Hz for 3 phases motors
60 Hp at 460/480 V AC 60 Hz for 3 phases motors
60 hp at 575/600 V AC 60 Hz for 3 phases motors
Compatibility code LC1D
Pole contact composition 3 NO
Contact compatibility M11
Protective cover With
[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit
125 A (at 60 °C) for power circuit
Irms rated making capacity 1100 A at 440 V AC for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 1100 A 40 °C - 1 s for power circuit
800 A 40 °C - 10 s for power circuit
400 A 40 °C - 1 min for power circuit
135 A 40 °C - 10 min for power circuit
140 A - 100 ms for signalling circuit
120 A - 500 ms for signalling circuit
100 A - 1 s for signalling circuit

Oct 5, 2023
1
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
200 A gG at <= 690 V coordination type 1 for power circuit
160 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 0.8 mOhm - Ith 125 A 50 Hz for power circuit
Power dissipation per pole 12.5 W AC-1
7.2 W AC-3
7.2 W AC-3e
[Ui] rated insulation voltage Power circuit: 1000 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947
Safety reliability level B10d = 1.3 Mcycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20 Mcycles contactor with mechanical load conforming to EN/ISO
13849-1
Mechanical durability 4 Mcycles
Electrical durability 1.2 Mcycles 95 A AC-3
1.3 Mcycles 125 A AC-1
1.2 Mcycles 95 A AC-3e
Control circuit type AC at 50/60 Hz standard
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.8...1.1 Uc (-40…55 °C):operational AC 50 Hz
0.85...1.1 Uc (-40…55 °C):operational AC 60 Hz
0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
1...1.1 Uc (55…70 °C):operational AC 50/60 Hz
Inrush power in VA 245 VA 60 Hz cos phi 0.75 (at 20 °C)
245 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA 26 VA 60 Hz cos phi 0.3 (at 20 °C)
26 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 6…10 W at 50/60 Hz
Operating time 20...35 ms closing
6...20 ms opening
Maximum operating rate 3600 cyc/h 60 °C
Connections - terminals Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with
cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible with
cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible
without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible
without cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without
cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without
cable end
Power circuit: connector 1 4…50 mm² - cable stiffness: flexible without cable end
Power circuit: connector 2 4…25 mm² - cable stiffness: flexible without cable end
Power circuit: connector 1 4…50 mm² - cable stiffness: flexible with cable end
Power circuit: connector 2 4…16 mm² - cable stiffness: flexible with cable end
Power circuit: connector 1 4…50 mm² - cable stiffness: solid without cable end
Power circuit: connector 2 4…25 mm² - cable stiffness: solid without cable end
Tightening torque Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
Power circuit: 12 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm
Power circuit: 12 N.m - on connector hexagonal screw head 4 mm
Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No
2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
Type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit

2
Non-overlap time 1.5 Ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting support Rail
Plate

Environment
Standards EN/IEC 60947-1
EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
Product certifications IECEE CB Scheme
UL
CSA
CCC
EAC
LROS (Lloyds register of shipping)
RINA
BV
DNV-GL
IP degree of protection IP20 front face conforming to IEC 60529
Protective treatment TH conforming to IEC 60068-2-30
Climatic withstand Conforming to IACS E10 exposure to damp heat
Permissible ambient air temperature around the -40…60 °C
device 60…70 °C with derating
Operating altitude 0...3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open (2 Gn, 5...300 Hz)
Shocks contactor open (8 Gn for 11 ms)
Vibrations contactor closed (3 Gn, 5...300 Hz)
Shocks contactor closed (10 Gn for 11 ms)
Height 127 mm
Width 85 mm
Depth 130 mm
Net weight 1.61 kg

Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 14.000 cm
Package 1 Width 13.500 cm
Package 1 Length 9.500 cm
Package 1 Weight 1.556 kg
Unit Type of Package 2 S02
Number of Units in Package 2 5
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 8.090 kg
Unit Type of Package 3 P06
Number of Units in Package 3 80
Package 3 Height 75.000 cm
Package 3 Width 60.000 cm
Package 3 Length 80.000 cm
Package 3 Weight 140.260 kg

3
Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation
REACh Declaration
REACh free of SVHC Yes
EU RoHS Directive
Compliant EU RoHS Declaration
Toxic heavy metal free Yes
Mercury free Yes
China RoHS Regulation
China RoHS Declaration
RoHS exemption information
Yes
Environmental Disclosure
Product Environmental Profile
WEEE The product must be disposed on European Union markets following specific
waste collection and never end up in rubbish bins
PVC free Yes

Contractual warranty
Warranty 18 months

4
Product data sheet LC1D95M7
Dimensions Drawings

Dimensions

(1) Minimum electrical clearance

LC1 D80 D95

a 85 85

b1 with LA4 D●2 135 135

with LA4 135 –


DB3 or LAD
4BB3

with LA4 142 142


DF, DT

with LA4 150 150


DM, DW, DL

c without cover or add-on blocks 125 125

with cover, 130 130


without add-
on blocks

c1 with LAD N (1 contact) 150 150

with LAD N 158 158


or C (2 or 4
contacts)

c2 with LA6 DK10, LAD 6DK 170 170

c3 with LAD T, R, S 178 178

with LAD 182 182


T, R, S and
sealing
cover

5
Product data sheet LC1D95M7
Connections and Schema

Wiring

You might also like