5 Electrical

The document outlines the electrical layout and architectural details for a proposed building in Accra, Ghana, including various rooms such as bedrooms, kitchens, and lavatories. It emphasizes the contractor's responsibility for setting out the building correctly and ensuring compliance with local regulations and standards. Additionally, it includes notes on quality control and the verification of dimensions and services on site.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
34 views1 page

5 Electrical

The document outlines the electrical layout and architectural details for a proposed building in Accra, Ghana, including various rooms such as bedrooms, kitchens, and lavatories. It emphasizes the contractor's responsibility for setting out the building correctly and ensuring compliance with local regulations and standards. Additionally, it includes notes on quality control and the verification of dimensions and services on site.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

BALCONY BALCONY

BALCONY BALCONY
BEDROOM STORE LAUNDRY STORE BEDROOM
BEDROOM STORE LAUNDRY STORE BEDROOM
KITCHEN KITCHEN
KITCHEN KITCHEN
LAVATORY LAVATORY
LAVTORY LAVTORY LAUNDRY
LAUNDRY
LAVATORY LAVATORY
LAVTORY CLOSET LAVTORY

11
CLOSET
11

DINING DINING
DINING DINING
10
10 12 9
12 9 13 8
PASS
13 8
PASS PASS. 14 7 PASS.
7 6

16R x 197
15G x 250
BEDROOM
14
BEDROOM
15
6
16R x 197
15G x 250

BEDROOM BEDROOM 5
15 16
16 5 DOWN 4
DOWN 4 3
3 2
2 1
1 UP
UP
LAVATORY CLOSET CLOSET LAVATORY
LAVTORY LAVTORY
LIVING AREA LIVING AREA
LIVING AREA LIVING AREA
BEDROOM LIFT BEDROOM
LIFT BEDROOM
BEDROOM
WC WC WC WC
BALCONY BALCONY
TERRACE
DOO - 257
WHD 3,197 x2,605
ELECTRICAL LAYOUT FOR GROUND PLAN 1299
ELECTRICAL LAYOUT FOR TYPICAL FIRST , SECOND & THIRD FLOOR PLAN
SCALE 1:100mm SCALE 1:100mm
WALL MOUNTED FITTING 13A TWIN SOCKET OUTLET CHANDELIA
2OA DP SWITCHC AC CEILING MOUNTED COMPATED
MIRROW LIGHT POINT
FLOURESCENT
CEILING FAN TELEPHONE OUTLET SUSPENDED MOUNTED COMPACT
FLOURESCENT
REGULATOR POINT WATER HEATER SWITCH
TWO FEET WIDE FLOURESCENT
2 TV OUTLET
ONE GANG TWO WAY LIGHTTING SWITCH METER CASH POWER
2
COOKER OUTLET
TWO GANG TWO WAY LIGHTTING SWITCH
ELECTRICAL LAYOUT LEGEND
13A SINGLE SOCKET OUTLET DISTRIBUTION BOARD
NOTE Contractor is responsible for correct setting out of the buildings, all external and
internal walls with particular reference to boundaries building lines etc.
BBS ESTATE & CONSTRUCTION description ARCHITECTURE DETAILS
Copyright and right of reproduction of this drawing or any portion thereof, is Contractor to verify all levels, heights and dimensions on putting any work to
hand ARCHITECTURE, PLANNING, CONSULTION
PROPOSED BUILDING TO BE ELECTRICAL PLAN
reserved by the designer ACCRA,GHANA
Any errors, discrepancies or omissions to be reported to the designer All Contractors to check the details shown on this drawing for compliance with
standards of good building practice with particular reference to special
email. blessing.building@gmail.com BUILT @ T.M.A drawn ENGR. MESHACK date
immediately. Any queries arising from all the above must be reported to APRIL , 2025
requirements necessitated by local and/or site conditions and to report any
the designer for clarification before any work is put to hand. This
drawing is not to be scale. Figured dimensions to be used at all times. comment to the designer. QUARTEY PAPAFIO HILL check by scale
AS SHOWN
cleint
Quality of all materials, workmanship and conditions should comply with the Contractors are to ensure that all details shown on this drawing are in compliance
SANTEO designed
FRED OPPONG
minimum standard specified in the standard preambles in the Bills of Quantities. with Local Authority by- laws and regulations. ENGR. MESHACK sheet n0
All structural steel and concrete work should comply with structural engineers Contractors are to locate and identify existing services on site and to protect GREATER ACCRA A-005.
details. these from damage throughout the duration of the works.