Package Air-Cooled Type Chiller

The document outlines specifications and purposes for various HVAC equipment and components, including air-cooled chillers, cooling towers, split-type air conditioners, pumps, fans, piping systems, and valves. Each item is detailed with its specifications such as capacity, power, and voltage, along with its intended function in the HVAC system. Additionally, it includes consumables and support items necessary for installation and maintenance.

Uploaded by

Tricia Merculio
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
23 views10 pages

Package Air-Cooled Type Chiller

The document outlines specifications and purposes for various HVAC equipment and components, including air-cooled chillers, cooling towers, split-type air conditioners, pumps, fans, piping systems, and valves. Each item is detailed with its specifications such as capacity, power, and voltage, along with its intended function in the HVAC system. Additionally, it includes consumables and support items necessary for installation and maintenance.

Uploaded by

Tricia Merculio
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 10

Package Air-Cooled Type Chiller

• Specification: 200 TR, 1,871–2,271 LPM, 114 kW,


380V / 3PH / 60Hz
• Purpose: Provides central cooling for large HVAC
systems using air-cooled condensers.

Cooling Tower
• Specification: Induced draft type, cross flow, 200TR,
2,271 LPM, 14.92kW, 380V / 3Ø / 60Hz
• Purpose: Removes heat from the chiller water system
via evaporation and air circulation.

Split Type Air Conditioners (FCU)


a. FCU-A + ACCU-A
• Specification: 4,356 Kcal/hr, 935 CMH, 1.86kW, 230V /
1Ø / 60Hz
• Purpose: Wall-mounted indoor unit for room-specific air
conditioning.
b. FCU-B + ACCU-B
• Specification: 3,024 Kcal/hr, 595 CMH, 1.31kW, 230V /
1Ø / 60Hz
• Purpose: Wall-mounted unit for smaller room air
conditioning needs.

Hangers & Supports (Mechanical)


• Specification: 1 lot
• Purpose: Secures piping and mechanical systems in place.

Consumables (Mechanical)
• Specification: 1 lot
• Purpose: Includes adhesives, sealants, gaskets, fasteners, etc.
Chilled Water Pumps (CHWP 1–3)
• Specification: End suction centrifugal, 1,817.0 LPM,
30.49M TDH, 14.92kW, 1,750RPM, 400V / 3PH / 60Hz
• Purpose: Circulates chilled water from the chiller to air
handlers and fan coils.
Condenser Water Pumps (COWP 1–3)
• Specification: End suction centrifugal, 2,271.0 LPM,
24.39M TDH, 24.39kW, 1,750RPM, 400V / 3PH / 60Hz
• Purpose: Circulates condenser water from chiller to
cooling towers.

Exhaust Fans
a. EF-6: Propeller Type
• Specification: 750Ø, 10,200 CMH, 0.56kW, 230V / 1Ø / 60Hz,
belt drive
• Purpose: General exhaust for large air volume spaces.
b. EF-7: Tubular Type
• Specification: 500Ø, 15,300 CMH, 5.6kW, 380V / 3Ø / 60Hz,
belt drive
• Purpose: Low RPM, high-volume exhaust for industrial use.
c. EF-8: Propeller Type
• Specification: 400Ø, 3,400 CMH,
0.36kW, 230V / 1Ø / 60Hz, belt drive
• Purpose: Wall-mounted exhaust
for smaller rooms or enclosures.

Supply Fans
a. SF-6: Industrial Type Propeller Exhaust Fan
• Specification: 750Ø, 10,200 CMH, 0.56kW, 230V / 1Ø / 60Hz, belt
drive
• Purpose: Ventilates large spaces by extracting air using propeller
motion.
b. SF-7: Tubular Type Low RPM High Volume Exhaust Fan
• Specification: 500Ø, 15,300 CMH, 5.6kW, 380V / 3Ø / 60Hz, belt drive
• Purpose: Industrial-grade fan for quiet, high-capacity air removal.

c. PB-F: Centrifugal Forward Curve


Pressurization Blower
• Specification: 8,500 CMH, 3.75kW, 400V /
3Ø / 60Hz, 500Ø WDI
• Purpose: Delivers pressurized air for
stairwells or escape routes.

Chilled Water Piping System (Distribution)


Galvanized Iron (G.I.) Pipes – Sch. 40 ERW
• Specification: 300Ø (33 lm), 200Ø (20 lm), 150Ø (9
lm), 100Ø (6 lm)
• Purpose: Primary piping for chilled water
distribution; durable and pressure-rated.

Welded Fittings
• Specification: 300Ø, 200Ø, 150Ø, 100Ø – Elbows,
Tees, Reducers
• Purpose: Facilitates direction change, branching, or
size transitions in chilled water lines.

Lateral Tee Reducer


• Specification: Sizes from 250 × 200 to 100 × 65 mm
• Purpose: Allows branching to smaller-diameter lines from
larger mains.

Pipe Insulation – Polyolefin Cross-Linked, 32 mm


thick
• Specification: 300Ø (33 lm), 200Ø (20 lm), 150Ø (9 lm), 100Ø (6 lm)
• Purpose: Maintains chilled water temperature and prevents condensation.
Hangers & Supports (Chilled Water)
• Specification: 1 lot
• Purpose: Structural supports for suspended piping.

Misc. Items (Chilled Water)


• Specification: 1 lot
• Purpose: Includes bolts, gaskets, wraps, and sealants.

Main AC Plant Piping


Cooling Tower – Condenser Water Piping System.
Fittings – Lateral Tee / Tee Reducer
• Specification: Sizes from 300 × 300 to 150 × 125
• Purpose: Distributes water in multiple directions, often with a size
transition.
Elbow 45°
• Specification: Sizes 300Ø to 150Ø
• Purpose: Provides gradual directional change in condenser water
pipes.

Reducer
• Specification: 300 × 200 mm²
• Purpose: Reduces pipe size in-line.

Slip-on Flanges
• Specification: 300Ø, 250Ø, 200Ø, 150Ø
• Purpose: Connects pipes with bolted assemblies, ensuring
serviceability.
Blind Flange
• Specification: 300Ø (7 pcs)
• Purpose: Seals pipe ends for future connection or
isolation.

Make-up Water Piping (Potable & Non-potable)


• Specification: 50 mm G.I. Pipe (17 lm)
• Purpose: Supplies additional water to replenish losses in the HVAC system.

Chillers & Pumps


G.I. Pipes – Sch. 40
• Specification: 300 mmØ (21 lm), 200 mmØ (28 lm), 150 mmØ (25 lm), 125 mmØ
(25 lm)
• Purpose: Circulates chilled water between chillers and the system.
Fittings – Lateral Tee / Tee Reducer
• Specification:
◦ 300 × 200 (14 pcs)
◦ 300 × 150 (3 pcs)
◦ 300 × 125 (3 pcs)
◦ 200 × 150 (3 pcs)
◦ 200 × 125 (3 pcs)
• Purpose: Connects pipes with size reduction for distribution.
Elbow 45°
• Specification:
◦ 200 mmØ (3 pcs)
◦ 125 mmØ (6 pcs)
• Purpose: Provides angled directional change in pipe routing.

Elbow 90°
• Specification:
◦ 300 mmØ (3 pcs)
◦ 200 mmØ (6 pcs)
◦ 150 mmØ (6 pcs)
◦ 125 mmØ (6 pcs)
• Purpose: Enables 90° turns in piping systems.
Reducers
• Specification: 300 × 200 (6 pcs)
• Purpose: Reduces pipe size to connect different
diameters.

Slip-on Flanges
• Specification: 300 mmØ (2 pcs), 200 mmØ (2 pcs)
• Purpose: Connects pipes with bolt-on assembly for service access.
Blind Flange
• Specification: 300 mmØ (2 pcs)
• Purpose: Seals pipe ends for maintenance or future expansion.

Pipe Insulation – Polyolefin, Cross-Linked (32 mm thick)


• Specification:
◦ 300 mmØ (21 lm)
◦ 200 mmØ (28 lm)
◦ 125 mmØ × 1.2 m (22 pcs)
• Purpose: Insulates chilled water lines to prevent energy loss and condensation.
Copper Pipes
• Specification: 15.88 mmØ (22 lm), 9.52 mmØ (12 lm)
• Purpose: Transports refrigerant in HVAC systems

Copper Pipe Insulation


• Specification: 15.88 mmØ × 25 mm thk. (22 lm), 9.52
mmØ × 25 mm thk. (12 lm)
• Purpose: Prevents condensation and reduces heat
gain/loss

Copper Elbow
• Specification: 15.88 mmØ (24 pcs), 9.52 mmØ (16 pcs)
• Purpose: Changes direction of copper refrigerant lines
Copper Coupling
• Specification: 15.88 mmØ (9 pcs), 9.52 mmØ (6 pcs)
• Purpose: Joins two copper pipes of the same diameter

Refrigerant Charge
• Specification: 9 kg
• Purpose: Supplies refrigerant for system operation
Nitrogen Flushing/Testing
• Specification: 1 lot
• Purpose: Cleans and pressure-tests copper lines

Polyethylene/Blue Tape
• Specification: 1 lot
• Purpose: Sealing and labeling piping systems

Hangers & Support (Refrigerant Lines)


• Specification: 1 lot
• Purpose: Provides structural support for copper piping
Misc. Consumables (Refrigerant Lines)
• Specification: 1 lot
• Purpose: Includes brazing rods, flux, clamps, etc.

Butterfly Valve (Motorized)


• Specification: 200 mmØ (3 pcs), 150 mmØ (3 pcs)
• Purpose: Controls water flow in cooling towers, used when Large
diameter piping, Hard-to-reach locations, Precise flow control needed

Auto Balancing Valve


• Specification: 150 mmØ–125 mmØ (3 pcs)
• Purpose: Maintains balanced water flow
across branches
Equalizing Valve
• Specification: 200 mmØ–150
mmØ (3 pcs)
• Purpose: Balances water level or
pressure between circuits

Check Valve
• Specification: 200 mmØ (3 pcs),
150 mmØ (3 pcs)
• Purpose: Prevents backflow in
pump lines

Strainer
• Specification: 200 mmØ (3 pcs), 150 mmØ (3 pcs)
• Purpose: Filters debris to protect valves and pumps

Concentric Reducer
• Specification: 200 × 150 mmØ (3 pcs), 150 × 125 mmØ
(3 pcs)
• Purpose: Reduces pipe size concentrically for inline
transitions

Eccentric Reducer
• Specification: 200 × 150 mmØ (3 pcs), 150 ×
125 mmØ (3 pcs)
• Purpose: Reduces pipe size while maintaining
bottom/top level
Flange Adapter
• Specification: 200 mmØ (3 pcs), 150 mmØ (3 pcs)
• Purpose: Connects pipes to flanged equipment

Flexible Coupling
• Specification: 200 mmØ (3 pcs), 150 mmØ (3
pcs)
• Purpose: Absorbs vibration and misalignment
in piping

Pressure Gauge (Oil Filled)


• Specification: 3 pcs
• Purpose: Monitors pressure in the piping system

Blowdown Valve
• Specification: 40 mmØ (6 pcs)
• Purpose: Drains sediment or excess water from the system
Ball Valve
• Specification: 14 pcs
• Purpose: General-purpose isolation valve

Threaded Elbow
• Specification: 1/2" (6 pcs)
• Purpose: Changes direction in threaded pipe
systems

Bushing Reducer
• Specification: 1/2" × 1/4" (6 pcs)
• Purpose: Adapts from larger to smaller threaded
fittings

B.I. Pipe Short Nipple


• Specification: 1/4" × 4" (6 pcs)
• Purpose: Short connector for threaded fittings or
valves