Ceragon
Local: https://[fec0::c0:a8:1:1]
Far end: https://[fec0::c0:a8:1:2]
Pc ip: fec0::c0:a8:1:5
Len:120
Gw ip: fec0::c0:a8:1:1
admin/admin
Services – add
Service id – 1
SERVICE TYPE – MP
SELECT MP – SERVICE POINTS
>>>>>
(.)GENERAL
Add- sap bundle-c
Select- ethernet slot1 port7
Add – snp s-tag
Select – radio slot1-port1
S-VLAN encapsulation 16
Antenna cpri link p5 – mw config p7
To check/config mgmt vlan
Select – 1025 MNG – Service points – add
Service point type -MNG
Interface locatio – ethernet slot1 port 7(working port)
Attached interface type – dot1q
C-VLAN encapsulation - <vlan id>
Apply
Ethernet – general setting – mru(mtu) 9612 (change in 4g bts also)
For ZTE 3g vlans
Services -> add ->service type – MP (give name in evc id) -> apply
Service points -> add -> Pre defined options -> SNP s-tag
Interface location -> radio slot1 port 1
Attached interface type -> s-tag
S-VLAN encapsulation -> 14 (any number other than 16(used))
Apply
Add -> Pre defined options -> SAP dot1q
Interface location -> ETH slot 1 port 7
Attached interface type – dot1q
C-VLAN encapsulation - <3g vlan>
Apply
----------------------------------------------------------------
for changing MANAGEMENT traffic from one port to another
----------------------------------------------------------------
configuration
DCN- static route
take snapshot - delete
network interface - take sapshot
delete only uplink interface - (dot delete BPETH-1-3-1, BPETH-1-6-1)
Provision a new Management Vlan Interface ServiceSwitch-0-0-99
select uplink port eg eth-1-4-2
enter mgmt vlan eg 801
broadcast interface - enable
ip address - from snapshot
Netmask Length -28
next - apply
Add a new Static Route
Network Interface - select uplink interface eg eth-1-4-1
Destination Network IP Address 0.0.0.0
Destination Network Address Mask Length 0
Next Hop IP Address - from snapashot
Advertise Route - enable
apply
-------------------------------------------------------------------------
-
L2 SERVICES is purely for data traffic switching i CEF cards
1. add FPtemplate (add vlans)
2. add ELAN sevice
3. add FPtemplate in ELAN service
NOTE: you can pass any vlans bw ports in CEF cards but Management vlan
(eg 801)
require additional config
to pass / configure management vlan bw ports
elan services - View Management ELANServices
- cpu - add port (ports with MGMT vlan (eg:801))
since CPU is not available in CEF12 card it is not possible to configure
MGMT vlans bw ports.
so, 4g - 4g cascade CEF12 with different vlan - possible
4g - 4g cascade CEF12 with different vlan - NO
4g - 2g/3g cascade CEF12 possible.
--------------------
for untagged vlans
--------------------
L2 Services - port config - switch param - PVID Egress Untag -enable
Acceptable Frame Policy - accept all