0% found this document useful (0 votes)
19 views32 pages

Cu 906000

The Schneider Electric Mureva Enclosures Catalogue 2023 presents a comprehensive range of waterproof enclosures designed for both commercial and residential installations, emphasizing sustainability and efficiency. The Mureva product line incorporates at least 20% recycled plastic and offers features such as ease of installation, ergonomic design, and compliance with environmental regulations. The catalogue includes detailed specifications, product offerings, and technical data for various enclosure types, catering to diverse installation needs.

Uploaded by

zhang quan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
19 views32 pages

Cu 906000

The Schneider Electric Mureva Enclosures Catalogue 2023 presents a comprehensive range of waterproof enclosures designed for both commercial and residential installations, emphasizing sustainability and efficiency. The Mureva product line incorporates at least 20% recycled plastic and offers features such as ease of installation, ergonomic design, and compliance with environmental regulations. The catalogue includes detailed specifications, product offerings, and technical data for various enclosure types, catering to diverse installation needs.

Uploaded by

zhang quan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 32

Mureva

Enclosures
Catalogue 2023

se.com
www.se.com

About our Company


Sustainability is at the core of our purpose, culture and business as we
accelerate our contributions to a sustainable and inclusive world.

Schneider Electric
in figures

€34 bn
2022 revenues

128.000
employees in 100+
countries

We empower our
650,000+ strong partner
ecosystem to expand our
coverage, and we arm
our 4,200+ EcoXpert
program partners
to drive new digital
business opportunities.

We provide end-point to cloud intergration connecting products, controls,


software and services.

Our mission is to be your digital partner for sustainability and efficiency.

Targets by 2025

80% 800 1,000 On our way to

net-zero by
green revenue
million tons top suppliers
of CO2 emissions
savings for our
to reduce CO2 emissions
by 50%
2030
customers (since 2018)

2
www.se.com

Pioneering the future of


intelligent buildings and
the iot for shared customers
+2.5B
Urban population
growth by 2050

Building digitization

x3 in 6 years

+60%
Electricity consumption
planned for 2035

3
www.se.com

Green Premium
TM

An industry leading portfolio of offers delivering sustainable value

Green The Green Premium program stands for our commitment to deliver
customer valued sustainable performance. It has been upgraded
Premium
TM
with recognized environmental claims and extended to cover all
offers including Products, Services and Solutions.

CO2 and P&L impact through… Resource Performance


More than 75% of our Green Premium brings improved resource efficiency throughout an asset’s
product sales offer superior lifecycle. This includes efficient use of energy and natural resources, along
transparency on the material with the minimization of CO2 emissions.
content, regulatory information
and environmental impact of Cost of ownership optimization through… Circular Performance
our products: We’re helping our customers optimize the total cost of ownership of their
assets. To do this, we provide IoT-enabled solutions, as well as upgrade,
• RoHS compliance repair, retrofit, and remanufacture services.
• REACh substance information
• Industry leading # of PEP’s* Peace of mind through… Well-being Performance
• Circularity instructions Green Premium products are RoHS and REACh compliant. We’re going
beyond regulatory compliance with step-by-step substitution of certain
materials and substances from our products.

Improved sales through… Differentiation


Green Premium delivers strong value propositions through third-party
Discover what we labels and services. By collaborating with third-party organizations we can
mean by green support our customers in meeting their sustainability goals such as green
Check your products! building certifications.

*PEP: Product Environmental Profile (i.e. Environmental Product Declaration)

4
Contents www.se.com

Contents
About our Company............................................................................................2
Mureva: an expanded product line for your installations.....................................6
Products for robust, waterproof installations from panel to socket.....................6
Presentation ........................................................................................................7
Mureva Enclosures................................................................................................................7
Functions and technical data .............................................................................8
Mureva Enclosures................................................................................................................8
Modular and mini enclosures, enclosures with interface................................................................................. 8
International Offer (A): 650°C, KnockOut entries, Earth Terminal Blocks*................................................... 8
International Offer (D): 650°C, KnockOut entries, Earth/Neutral Terminal Blocks...................................... 10
Polyvalent Enclosures and Interface modules................................................................................................ 12
International Offer (A): 650°C, KnockOut entries........................................................................................ 12
Enclosures for socket outlets ......................................................................................................................... 13
International Offer (A): 650°C, KnockOut entries, without Terminal Blocks................................................ 13
Modular and mini enclosures, enclosures with interface................................................................................ 14
Offer (B): 750°C, KnockOut entries, Earth Terminal Blocks........................................................................ 14
Modular and mini enclosures, enclosures with interface................................................................................ 15
Offer (B): 750°C, KnockOut entries, Earth Terminal Blocks........................................................................ 15
Enclosures for socket Outlets.......................................................................................................................... 16
Offer (B): 750°C, KnockOut entries, with Earth Terminal Blocks................................................................. 16
Polyvalent Enclosures and Interface modules................................................................................................ 17
Offer (B): 750°C, KnockOut entries............................................................................................................. 17
Offer (C): 650°C, Smooth entries................................................................................................................. 18
Modular and mini enclosures, enclosures with interface................................................................................ 19
Offer (C): 650°C, Smooth entries................................................................................................................. 19
Offer (C): 650°C, KnockOut entries............................................................................................................. 20
Enclosures for socket outlets ......................................................................................................................... 21
Offer (C): 650°C, KnockOut entries, without Terminal Blocks..................................................................... 21
Accessories........................................................................................................22
Dimensions.........................................................................................................26
Index...................................................................................................................30

5
www.se.com

PB124620.eps
Mureva: an expanded product line for your installations

A product line designed specifically for demanding commercial and residential environments
All of Schneider Electric’s waterproof solutions are now part of the Mureva product line.
Kaedra and Pratika are now Mureva.
These well-known products will continue to improve to bring electricians the benefits they have come to expect:
• Fast, simple installation.
• Best-in-class design for reliable electrical installations that keep customers’ businesses and installations running.
• An innovative product line that reflects the latest market trends, backed by:
- expert sales representatives
- a network of responsive local distributors to work with professionals and supply the products they need for
their installation jobs
• An environmental policy compliant and challenging the industrial processes to protect our environment.
carton_emballage.eps

Mureva, the sustainable choice


European-made Mureva Enclosures products contain a minimum of 20% recycled plastic content, and
Mureva’s brown packaging is part of our program to make 100% of primary and secondary packaging from
cardboard containing a minimum of 70% recycled content. Finally, Mureva products are Green Premium™
because guarantying the availability of environmental performance data and disclosures like Product
Environmental Profiles (PEP), compliant with RoHS and REACH regulations concerning hazardous materials,
and providing circularity profiles with end-of-life guidance and circular value propositions.

%
RECYCLED
PLASTIC
Most of the plastic component
CONTENT
contain recycled material.

Products for robust, waterproof installations from panel to socket


Mureva Modular Enclosures Mureva Industrial
Image_Mureva.eps

Image_Sockets.eps

These waterproof enclosures can


Sockets
accommodate from 3 to 72 modules, from
Ideal for installations that have to be
industrial sockets to modular protection
waterproof, these sockets are simple for
and control devices, for total peace of
electricians to connect, tool-free.
mind. They are compatible with Resi9
Compliant with the IEC 60309 standard,
devices for residential installations and
these sockets o er a high level of
Acti9 for commercial installations.
performance and ease of installation.
> Learn more
> Learn more

6
Presentation www.se.com

Mureva Enclosures
Waterproof enclosures

Mureva is thus a comprehensive and consistent solution for the installation of all
Schneider Electric Circuit breaker, incorporating safety, functionality, ergonomics
and attractive design.

The most comprehensive enclosure range


For the production of electrical enclosures Available in 7 versions from 3 to 72 modules
incorporating protection, control and distribution They allow installation of Modular circuit breakers up to
b Modular protection devices. 125 A, as well as non-Modular circuit breakers on slotted
b Socket Outlets. mounting plate.
b Pushbuttons and indicator lights, etc.
b Non-Modular circuit breakers (transformer, motor control, etc.).
PB124643.eps

Polyvalent enclosures
Available in 5 sizes.
For tertiary, Building,
They are designed for production of control
industrial sectors and
and monitoring Enclosures with non-modular
even residential
b For environments requiring type devices.
optimum protection of
persons and electrical Circuit Interface enclosures
breakers. Available in 2 versions with 3 or 4 openings.
They can be used by themselves, horizontally
or vertically, or associated with other
enclosures as cable trunking or interface
Ergonomics
b Mureva Enclosures offer
zone (control devices, indicator lights, etc.).
remarkable cabling space.
b Both the cable inlet and
internal distribution is simplified.
b The transparent doors enable
permanent, immediate checking
of operating conditions.
b The interface zones offer quick
access to socket Outlets and
control devices.
b The functional openings allow
rapid installation of all devices
directly or using matching plates.
b The frame and all its
possibilities guarantee assembly
time savings. Enclosures for socket
Outlets
b 90 x 100 mm openings
Available in versions with 1 to 8
openings.
They are characterised for the
new functional feature with
openings allowing installation of
all Mureva PK socket outlets or
the incorporation of control and
indicator light functions.
b 103 x 225 mm openings
Enclosures for Modular circuit breakers with interface Available in versions with 1 to 4
Available in 3 versions of 12, 24 and 36 modules. openings.
The interface zone offers the possibility, thanks to the They can accommodate the new
functional plates, of installing on the Enclosures front face, Mureva PKB interlock socket
control, indicator lights and Mureva PK series socket Outlets
Outlets of the domestic or industrial type. Polyvalent (smooth surface to
They thus ensure external operations with door closed be drilled).
granting IP65. Available in 5 sizes.

7
Functions and technical data www.se.com

Mureva Enclosures
Modular and mini enclosures, enclosures with interface
International Offer (A): 650°C, KnockOut entries, Earth Terminal Blocks*

3 to 12 module mini enclosures. Description


12 to 72 module enclosures.
Modular Enclosure
13983_Image.eps

b Reversible front face to allow right or left door opening.


b Adjustable DIN rail interdistance to (125-150-175 mm), with 2 possible depth
adaptations.
b Extractable chassis and different terminal possible installations.
b Equipped with Earth Terminal Blocks already mounted on support.
b Ergonomic handle equippable with keylock.
13978_Image.eps

Mini enclosure
b Embedded door to minimize dimensions, equippable with keylock.
b Possibility to insert terminals directly on dovetail on bottom Enclosures.
Mureva enclosures and mini enclosures for Modular circuit
breakers.
Modular Enclosure with interface
13992_Image.eps

b Propose an external interface on the right or left zone available to accommodate


buttons, indicator lights or socket outlets.
b Keeping a protected zone with din rail behind the door, to install modular circuit
breakers.
Technical data
Enclosures
In conformity with standards Empty enclosures IEC 60670-1 and 24
Equipped Enclosures IEC 61439-1 and 3
Enclosure colour Light grey RAL 7035 and transparent green door
Degree of protection IP IP65 (as per IEC 60529)
IK IK09 (as per IEC 62262)
Insulating Class 2

Mureva enclosure for Modular circuit breakers with interface. Additional characteristics
Operating temperature -25°C to +60°C
Flame and abnormal heat resistance: 650°C as per IEC 60695-2-11
Resistance to chemicals and atmospherics agents, ISO 4892-2
UV resistance according to
Optional locking of the door, sealing of the front face and front Keylock
plates
* Except mini modular.

8
Functions and technical data www.se.com

Mureva Enclosures
Modular and mini enclosures, enclosures with interface
International Offer (A): 650°C, KnockOut entries, Earth Terminal Blocks*

Enclosure catalogue numbers

Technical data Accessories with an enclosure cat. no. (2) Cat. no.
Row Total Pre-cutout (top and bottom) (1) Dimensions Marking Wiring class II Terminal Terminal block E = Earth terminal
mod. M 16 20 20 25 32 50 (mm) kit strap plugs in all block number of holes
enclosures support
PG 11 16 21 29/36 W H D 4 8 16 22 32
Mini-enclosures
1 3 - - - 1 - - 80 150 98 1 - 1 - - - - - - 13975
4 1 1 - 1 - - 123 200 112 1 - 1 - - - - - - 13976
6 1 1 - 1 - - 159 200 112 1 - 1 - - - - - - 13977
8 2 2 - 1 - - 195 200 112 1 - 1 - - - - - - 13978
12 2 2 - 2 1 - 267 200 112 1 - 1 - - - - - - 13979
Modular Enclosures
1 12 6 - 6 2 3 - 340 280 160 1 1 1 1 - - 1E - - 13981
18 - - 10 4 2 1 448 280 160 1 1 1 1 - - - 1E - 13982
2 24 6 - 6 2 3 - 340 460 160 2 1 1 1 - - - - 1E 13983
36 - - 10 4 2 1 448 460 160 2 1 1 1 - - - - 1E 13984
3 36 6 - 6 2 3 - 340 610 160 3 2 1 1 - - - - 1E 13985
54 - - 10 4 2 1 448 610 160 3 2 1 2 - - 1E - 1E 13986
4 72 - - 10 4 2 1 448 842 160 4 3 1 2 - - - - 2E 13987

Technical data Accessories with an enclosure cat. no. (2) Cat. no.
Row Total Slot Pre-cutout (top and bottom) (1)
Dimensions Marking Wiring Terminal Terminal block Plates for:
mod. for (mm) kit strap block number of holes
buttons, 65 x 85 90 x 100
plate support E = Earth terminal
indicator mm mm
(Type LGYT2Axx) lights socket socket
M 20 25 32 50 Outlets Outlets
PG 11 16 21 29/36 W H D 4 8 16 22 32 13138 13135 13137
Modular Enclosures with interface
1 12 1 10 4 2 1 448 280 160 1 1 1 - - 1E - - 1 - - 13990
2 24 3 10 4 2 1 448 460 160 2 2 1 - - - 1E - 3 - 1 13991
3 36 4 10 4 2 1 448 610 160 3 3 1 - - - - 1E 4 - 1 13992
(1) Concentric pre-cutouts of the PG and ISO/metric type (EN 50262).
(2) Accessories also delivered:
b mini enclosures: class II plugs.
b enclosures: class II plugs and blanking plates (5 modules of 18 mm per row).

Terminal block components Cat. no.


These components can be used to implement and install a terminal block:
b on the chassis near the conductor entry
LGYT4A01.eps

LGYT2A04.eps

LGYT2A08.eps

b on a DIN rail mounted on the enclosure chassis


b in the Prisma Plus Enclosures on the functional uprights
LGYT4A01
Terminal block junction
Compact associable terminal block junction kit Batch of 10 - LGYT4A01
LGYT2A04 LGYT2A08 Screw insulated terminal block
2 x 16v + 2 x 10v screw terminal block
LGYT2A16.eps

- LGYT2A04
+ 1 green and 1 blue covers (80 A) (3)
4 x 16v + 4 x 10v screw terminal block
- LGYT2A08
+ 1 green and 1 blue covers (80 A) (3) (4)
8 x 16v + 8 x 10v screw terminal block
- LGYT2A16
+ 1 green and 1 blue covers (80 A) (3)
11 x 16v + 11 x 10v screw terminal block
- LGYT2A22
LGYT2A16 + 1 green and 1 blue covers (80 A) (3)
16 x 16v + 16 x 10v screw terminal block
LGYT2A22.eps

- LGYT2A32
+ 1 green and 1 blue covers (80 A) (3)

Everything for the interface

Direct mounting With plate With plate With plate


LGYT2A22 cat. no. 13136 cat. no. 13137 cat. no. 13138
A B C D
LGYT2A32.eps

16/32 A slanting Domestic and LV LV and ELV socket Buttons, indicator


socket Outlets power oultets Outlets (65 x 65 mm lights and switches
(90 x 100 mm). (65 x 85 mm). and 75 x 75 mm). 16 and 22 mm diameter.
LGYT2A32

9
Functions and technical data www.se.com

Mureva Enclosures
Modular and mini enclosures, enclosures with interface
International Offer (D): 650°C, KnockOut entries, Earth/Neutral Terminal Blocks

3 to 12 module mini enclosures. Description


12 to 72 module enclosures.
Modular Enclosure
13433_Image.eps

b Reversible front face to allow right or left door opening.


b Adjustable DIN rail interdistance to (125-150-175 mm), with 2 possible depth
adaptations.
b Extractable chassis and different terminal possible installations.
b Equipped with Earth and Neutral Terminal Blocks already mounted on support.
b Ergonomic handle equippable with keylock.
13441_Image.eps

Mini enclosure
b Embedded door to minimize dimensions, equippabel with keylock.
b Possibility to insert terminals directly on dovetail on bottom Enclosures.
Mureva enclosures and mini enclosures for Modular circuit
breakers.
Modular Enclosure with interface
13440_Image.eps

b Propose an external interface on the right or left zone available to accommodate


buttons, indicator lights or socket outlets.
b Keeping a protected zone with din rail behind the door, to install modular circuit
breakers.
b Lateral flexible space for installation of non modular devices with 100 mm max
depth.

Technical data
Enclosures
In conformity with standards Empty enclosures IEC 60670-1 and 24
Equipped Enclosures IEC 61439-1 and 3
Mureva enclosure for Modular circuit breakers with interface.
Enclosure colour Light grey RAL 7035 and transparent green door
Degree of protection IP IP65 (as per IEC 60529)
IK IK09 (as per IEC 62262)
Insulating Class 2

Additional characteristics
Operating temperature -25°C to +60°C
Flame and abnormal heat resistance: 650°C as per IEC 60695-2-11
Resistance to chemicals and atmospherics agents, ISO 4892-2
UV resistance according to
Optional locking of the door, sealing of the front face and front Keylock
plates

Everything for the interface

Direct mounting With plate With plate With plate


cat. no. 13136 cat. no. 13137 cat. no. 13138
A B C D

16/32 A slanting socket Outlets Domestic and LV socket Outlets LV and ELV socket Outlets Buttons, indicator lights and switches
(90 x 100 mm). (65 x 85 mm). (65 x 65 mm and 75 x 75 mm). 16 and 22 mm diameter.

10
Functions and technical data www.se.com

Mureva Enclosures
Modular and mini enclosures, enclosures with interface
International Offer (D): 650°C, KnockOut entries, Earth/Neutral Terminal Blocks

Enclosure catalogue numbers

Technical data Accessories with an enclosure cat. no. (2) Cat. no.
Row Total Pre-cutout (top and bottom) (1) Dimensions Marking Wiring class II Terminal Terminal block Plates for:
mod. M 16 20 20 25 32 50 (mm) kit strap plugs in all block number of holes buttons, 65 x 85 90 x 100
enclosures support E = Earth terminal indicator mm mm
N = Neutral terminal lights socket socket
(Type LGYT2Axx) Outlets Outlets
PG 11 16 21 29/36 W H D 4 8 16 22 32 13138 13135 13137
Mini-enclosures
1 4 1 1 - 1 - - 123 200 112 1 - 1 1 1E/1N - - - - - - - 13441
6 1 1 - 1 - - 159 200 112 1 - 1 1 1E/1N - - - - - - - 13442
8 2 2 - 1 - - 195 200 112 1 - 1 1 - 1E/1N - - - - - - 13443
12 2 2 - 2 1 - 267 200 112 1 - 1 1 - 1E/1N - - - - - - 13444
Modular Enclosures
1 12 6 - 6 2 3 - 340 280 160 1 1 1 1 - 1E/1N - - - - 1 - 13431
18 - - 10 4 2 1 448 280 160 1 1 1 1 - - 1E/1N - - - 1 - 13432
2 24 6 - 6 2 3 - 340 460 160 2 1 1 1 - - - 1E/1N - - 2 - 13433
36 - - 10 4 2 1 448 460 160 2 1 1 1 - - - - 1E/1N - 2 - 13434
3 36 6 - 6 2 3 - 340 610 160 3 2 1 1 - - - - 1E/1N - 3 - 13435
54 - - 10 4 2 1 448 610 160 3 2 1 2 - - - 2E/2N - - 3 - 13436
4 72 - - 10 4 2 1 448 842 160 4 3 1 2 - - - - 2E/2N - 4 - 13437

Technical data Accessories with an enclosure cat. no. (2) Cat. no.
Row Total Slot Pre-cutout (top and bottom) Dimensions Marking Wiring class II Terminal Terminal block Plates for:
mod. for (1)
(mm) kit strap plugs in all block number of holes
buttons, 65 x 85 90 x 100
plate enclosures support E = Earth terminal
indicator mm mm
N = Neutral terminal
lights socket socket
M 20 25 32 50 (Type LGYT2Axx)
Outlets Outlets
PG 11 16 21 29/36 W H D 4 8 16 22 32 13138 13135 13137
Modular with interface
2 24 3 10 4 2 1 448 460 160 2 1 1 1 - - - 1E/1N - 3 2 - 13439
3 36 4 10 4 2 1 448 610 160 3 2 1 1 - - - - 1E/1N 4 3 - 13440
(1) Concentric pre-cutouts of the PG and ISO/metric type (EN 50262).
(2) Accessories also delivered:
b mini enclosures: class II plugs.
b enclosures: class II plugs and blanking plates (5 modules of 18 mm per row).

Terminal block components Cat. no.


These components can be used to implement and install a terminal block:
b on the chassis near the conductor entry
LGYT4A01.eps

b on a DIN rail mounted on the enclosure chassis


b in the Prisma Plus Enclosures on the functional uprights
LGYT4A01
Terminal block junction
Compact associable terminal block junction kit Batch of 10 - LGYT4A01
Screw insulated terminal block
2 x 16v + 2 x 10v screw terminal block
- LGYT2A04
+ 1 green and 1 blue covers (80 A) (3)
4 x 16v + 4 x 10v screw terminal block
- LGYT2A08
+ 1 green and 1 blue covers (80 A) (3) (4)
8 x 16v + 8 x 10v screw terminal block
- LGYT2A16
+ 1 green and 1 blue covers (80 A) (3)
11 x 16v + 11 x 10v screw terminal block
- LGYT2A22
+ 1 green and 1 blue covers (80 A) (3)
16 x 16v + 16 x 10v screw terminal block
- LGYT2A32
+ 1 green and 1 blue covers (80 A) (3)
LGYT2A04.eps

LGYT2A08.eps

LGYT2A16.eps

LGYT2A22.eps

LGYT2A32.eps

LGYT2A04 LGYT2A08 LGYT2A16 LGYT2A22 LGYT2A32

11
Functions and technical data www.se.com

Mureva Enclosures
Polyvalent Enclosures and Interface modules
International Offer (A): 650°C, KnockOut entries

The opaque door polyvalent enclosure provides a zone Description


to install non-Modular circuit breakers.
The polyvalent enclosure for socket Outlets provides Polyvalent Enclosures with Plain door
a row for Modular circuit breakers and a universal b Delivered with a slotted mounting plate to be mounted at the back.
zone. b Available depth for installation of non-Modular circuit breakers on slotted plate:
130 mm.
b Reversible front face to change door opening direction.
13193_Image.eps

Polyvalent enclosures with smooth front face


13195_Image.eps

b Flexible solution to allow mounting of any device on front empty face throughout
drilling.
b Internal space till 100 mm for tranfo or other devices to keep protected.

Interface modules enclosure


b This modules can be used to mount external pushbutton or can also act as cables
duct.

Polyvalent Mureva Polyvalent Mureva


enclosures with plain door. enclosures with smooth
front face. Technical data
Mureva Enclosures guarantee a high degree of protection and increased
dependability.
Enclosures
Enclosures that can be installed alone, In conformity with standards Empty enclosures IEC 60670-1 and 24
but also as an extension of another enclosure. Equipped Enclosures IEC 61439-1 and 3
Enclosure colour Light grey RAL 7035
Degree of protection IP IP65 (as per IEC 60529)
13993_Image.eps

IK IK09 (as per IEC 62262)


Insulating Class 2

Additional characteristics
Operating temperature -25°C to +60°C
Flame and abnormal heat resistance: 650°C as per IEC 60695-2-11
Resistance to chemicals and atmospherics agents, UVs
Optional locking of the door, sealing of the front face and front plates
Note: Polyvalent enclosures with smooth face can accomodate socket outlet till 63A (drilling the
Interface modules Mureva surface).
enclosures.

Enclosure catalogue numbers


Technical data Accessories with an enclosure cat. no. (2) Cat. no.
Nb of Dimensions (mm) Nb of Pre-cutout (top and bottom) (1) Wiring class II plugs Plates for:
op. mod. strap in all enclosures buttons, 65 x 85 mm 90 x 100 mm
indicator socket socket Outlets
M 16 20 25 32 50 lights Outlets
W H D PG 11 16 21 29/36 13138 13135 13137
Polyvalent Mureva
Polyvalent Enclosures with Plain door
- 340 460 160 - 6 6 2 3 - - 1 - - - 13195
- 448 460 160 - - 10 4 2 1 - 1 - - - 13197
- - 610 160 - - 10 4 2 1 - 1 - - - 13198
Polyvalent enclosures with smooth face
- 138 460 160 5 - 1 1 1 1 - 1 - - - 13189
- 236 460 160 8 - 2 2 3 3 1 1 - - - 13190
- 340 335 160 12+1 6 6 2 3 3 1 1 - - - 13191
- - 460 160 12+1 6 6 2 3 3 1 1 - - - 13192
- 448 460 160 18+1 - 10 4 2 2 1 1 - - - 13193
Interface modules enclosures
3 138 460 160 - - 1 1 1 - - 1 3 - 1 13993
4 138 610 160 - - 1 1 1 - - 1 4 - 1 13994
(1) Concentric pre-cutouts of the PG and ISO/metric type (EN 50262).
(2) Accessories also delivered:
b opaque door polyvalent enclosures: class II plugs, mounting plate.
b polyvalent enclosures for socket outlets: class II plugs, blanking plates (5 modules of 18 mm) and marking kit.

12
Functions and technical data www.se.com

Mureva Enclosures
Enclosures for socket outlets
International Offer (A): 650°C, KnockOut entries, without Terminal Blocks

Enclosures offering: Description


b a zone for industrial or domestic socket Outlets,
buttons or indicator lights. Enclosures for Socket Outlets
b a row for Modular circuit breakers protecting b Mini Enclosures and Enclosure allowing direct mount of IEC Panel Industrial
socket Outlets. sockets 16-32 A, straight and angled.
b Enclosure with big opening for interlock Switched socket outlets and related
protection on DIN.
13181_Image.eps
13186_Image.eps

13176_Image.eps
Technical data
Enclosures
In conformity with standards Empty enclosures IEC 60670-1 and 24
Equipped Enclosures IEC 61439-1 and 3
Enclosure colour Light grey RAL 7035 and transparent green wicket gate
Degree of protection IP IP65 (as per IEC 60529)
IK IK09 (as per IEC 62262)
Enclosure and mini enclosure for socket Outlets. Insulating Class 2

Additional characteristics
Operating temperature -25°C to +60°C
Flame and abnormal heat resistance: 650°C as per IEC 60695-2-11
Resistance to chemicals and atmospherics agents, UVs
Optional locking of the door, sealing of the front face and front plates

Enclosure catalogue numbers


Technical data Accessories delivered with an enclosure cat. no. (2) Cat. no.
Total Open Pre-cutout (top and bottom) (1)
Dimensions Wiring class II Plates cat. no.:
mod. M 16 20 25 32 50 (mm) strap plugs in all buttons, 65 x 85 mm 90 x 100 mm
enclosures indicator lights outlets outlets
PG 11 16 21 29/36 W H D 13138 13135 13137
Mini enclosures for socket outlets (65 x 85 mm openings)
4 1 - - 1 - - 98 248 98.5 - 1 - - - 13175
2 - - 1 - - 98 310 98.5 - 1 - 1 - 13176
3 - - 1 - - 98 392 98.5 - 1 - 1 - 13177
Enclosures for socket outlets (90 x 100 mm openings)
5 2 - 1 1 1 - 138 460 160 - 1 1 - 2 13178
8 4 - 2 2 3 - 236 460 160 1 1 1 - 4 13179
12 3 6 6 2 3 - 340 335 160 1 1 1 - 3 13180
6 6 6 2 3 - 340 460 160 1 1 2 - 6 13181
18 8 - 10 4 2 1 448 460 160 1 1 2 - 8 13182
Enclosures for interlocked socket outlets (103 x 225 mm openings)
5 1 - 1 1 1 - 138 460 160 - 1 - - - 13185
8 2 - 2 2 3 - 236 460 160 1 1 - - - 13186
12 3 6 6 2 3 - 340 460 160 1 1 - - - 13187
18 4 - 10 4 2 1 448 460 160 1 1 - - - 13188
(1) Concentric pre-cutouts of the PG and ISO/metric type (EN 50262).
(2) Accessories also delivered:
b mini enclosures: class II plugs.
b enclosures: class II plugs, blanking plates (5 modules of 18 mm per row) and a marking kit.
Note: flush-mounted socket outlets, see 93145.

13
Functions and technical data www.se.com

Mureva Enclosures
Modular and mini enclosures, enclosures with interface
Offer (B): 750°C, KnockOut entries, Earth Terminal Blocks

Enclosures offering: Description


b an interface zone always available for user and
that can accommodate buttons, indicator lights, Modular Enclosure
socket Outlets. b Reversible front face to allow right or left door opening.
b a zone, behind the door, to install b Adjustable DIN rail interdistance to (125-150-175 mm), with 2 possible depth
the modular enclosures. adaptations.
b Extractable chassis and different terminal possible installations.
b Equipped with Earth Terminal Blocks already mounted on support.
13972M_Image.eps

b Ergonomic handle equippable with keylock.


b Screwless earth terminals.
b XE DIN rail.
b Declipsable bar of support for Terminals.

Mini enclosure
b Embedded door to minimize dimensions, equippabel with keylock.
b Possibility to insert terminals directly on dovetail on bottom Enclosures.
b Screw earth terminals.
b XE DIN rail for Mini enclosure 8-12M.
b Declipsable bar of support for Terminals.

Modular Enclosure with interface


Mureva enclosure for modular enclosures with interface.
b Propose an external interface on the right or left zone available to accommodate
buttons, indicator lights or socket outlets.
b Keeping a protected zone with din rail behind the door, to install modular circuit
breakers.
b Lateral flexible space for installation of non modular devices with 100 mm max
depth.
b Screw earth terminals.
b XE DIN rail.
b Declipsable bar of support for Terminals.

3 to 12 module mini enclosures. Technical data


Add-on 12 to 72 module enclosures.
Enclosures
In conformity with standards Empty enclosures IEC 60670-1 and 24
13964M_Image.eps

Equipped switchboards IEC 61439-1 and 3


Enclosure colour Light grey RAL 7035 and transparent green door
Degree of protection IP IP65 (as per IEC 60529)
IK IK09 (as per IEC 62262)
Insulating Class 2
13958M_Image.eps

Additional characteristics
Operating temperature -25°C to +60°C
Flame and abnormal heat resistance: 750°C as per IEC 60695-2-11
Resistance to chemicals and atmospherics agents, ISO 4892-2
Mureva enclosure and mini enclosures for Modular circuit UV resistance according to
breakers. Optional locking of the door, sealing of the front face and front Keylock
plates

Everything for the interface


Direct mounting With plate cat. no. 13136 With platecat. no. 13137 With plate cat. no. 13138
A B C D

16/32 A slanting socket Outlets Domestic and LV power oultets LV and ELV socket Outlets Buttons, indicator lights and
(90 x 100 mm). (65 x 85 mm). (65 x 65 mm and 75 x 75 mm). switches 16 and 22 mm diameter.

14
Functions and technical data www.se.com

Mureva Enclosures
Modular and mini enclosures, enclosures with interface
Offer (B): 750°C, KnockOut entries, Earth Terminal Blocks

Enclosure catalogue numbers


Technical data Accessories delivered with an enclosure cat. no. (2) Cat. no.
Row Total Slot Dimensions Pre-cutout (1)
Marking kit Wiring class II Terminal Terminal block type and Plates for:
mod. for (mm) (top and bottom) strap plugs in all block number of holes buttons, 65 x 85 mm 90 x 100
plate enclosures support E = Earth terminals indicator power mm socket
screw lights outlets Outlets
M 20 25 32 50 (Type LGYT2Axx)

W H D PG 11 16 21 29/36 4 8 16 22 32 13138 13135 13137


Modular Enclosures with interface
1 12 1 448 280 160 10 4 2 1 1 1 1 1 - - 1E - - 1 - - 13970M
2 24 3 448 460 160 10 4 2 1 2 1 1 1 - - - 1E - 3 - 1 13971M
3 36 4 448 610 160 10 4 2 1 3 2 1 1 - - - - 1E 4 - 1 13972M
Row Total Dimensions Pre-cutout (1) Marking kit Wiring class II Terminal Terminal block type and Plates for:
mod. (mm) (top and bottom) strap plugs in all block number of holes buttons, 65 x 85 mm 90 x 100
enclosures support E = Earth terminals indicator power mm socket
screw lights outlets Outlets
M 16 20 20 25 32 50 (Type LGYT2Axx)

W H D PG 11 16 21 29/36 4 8 16 22 32 13138 13135 13137


Mini enclosures
1 3 80 150 98 - - - 1 - - 1 - 1 1 1E - - - - - - - 13956M
4 123 200 112 1 1 - 1 - - 1 - 1 1 1E - - - - - - - 13957M
6 159 200 112 1 1 - 1 - - 1 - 1 1 - 1E - - - - - - 13958M
8 195 200 121 2 2 - 1 - - 1 - 1 1 - 1E - - - - - - 13959M
12 267 200 121 2 2 - 1 1 - 1 - 1 1 - - 1E - - - - - 13960M
Row Total Dimensions Pre-cutout (1) Marking kit Wiring class II Terminal Terminal block type and Plates for:
mod. (mm) (top and bottom) strap plugs in all block number of holes buttons, 65 x 85 mm 90 x 100
enclosures support E(s) = Earth terminals indicator power mm socket
(screwless) lights outlets Outlets
M 16 20 20 25 32 50 (Type LGYT1Nxx)

W H D PG 11 16 21 29/36 5 14 24 13138 13135 13137


1+4(s) 3+11(s) 3+21(s)
Modular Enclosures
1 12 340 280 160 6 - 6 2 3 - 1 1 1 1 - 1E(s) - - - - 13962M
18 448 280 160 - - 10 4 2 1 1 1 1 1 - - 1E(s) - - - 13963M
2 24 340 460 160 6 - 6 2 3 - 2 1 1 1 - - 1E(s) - - - 13964M
36 448 460 160 - - 10 4 2 1 2 1 1 1 - 1E(s) 1E(s) - - - 13965M
3 36 340 610 160 6 - 6 2 3 - 3 1 1 1 - 1E(s) 1E(s) - - - 13966M
54 448 610 160 - - 10 4 2 1 3 1 1 2 - - 2E(s) - - - 13967M
4 72 448 842 160 - - 10 4 2 1 4 1 1 2 - - 3E(s) - - - 13968M
(1) Concentric pre-cutouts of the PG and ISO/metric type (EN 50262). (2) Accessories also delivered:
b mini enclosures: class II plugs.
b enclosures: class II plugs and blanking plates (5 modules of 18 mm per row).
Terminal block components Cat. no.
Terminal block junction
LGYT4A01.eps

Compact associable terminal block junction kit Batch of 10 - LGYT4A01


LGYT4A01 Screw insulated terminal block
2 x 16v + 2 x 10v screw terminal block + 1 green and 1 blue covers (80 A) (3) - LGYT2A04
LGYT1E05.eps

4 x 16v + 4 x 10v screw terminal block + 1 green and 1 blue covers (80 A) (3) (4) - LGYT2A08
8 x 16v + 8 x 10v screw terminal block + 1 green and 1 blue covers (80 A) (3) - LGYT2A16
LGYT1••05 11 x 16v + 11 x 10v screw terminal block + 1 green and 1 blue covers (80 A) (3) - LGYT2A22
16 x 16v + 16 x 10v screw terminal block + 1 green and 1 blue covers (80 A) (3) - LGYT2A32
LGYT1E14.eps

Compact associable screwless terminal blocks (1) Earth Neutral


1 x 6/25 v (screw) + 4 x 1.5/4 v(2) (push/in) terminal block (63 A) + jumper LGYT1E05 LGYT1N05
LGYT1••14 3 x 6/25 (screw) + 11 x 1.5/4
v v(2)
(push/in) terminal block (63 A) + jumper LGYT1E14 LGYT1N14
3 x 6/25 v (screw) + 21 x 1.5/4 v(2) (push/in) terminal block (63 A) + jumper LGYT1E24 LGYT1N24
LGYT1E24.eps

LGYT1••24
LGYT2A04.eps

LGYT2A08.eps

LGYT2A16.eps

LGYT2A22.eps

LGYT2A32.eps

LGYT2A04 LGYT2A08 LGYT2A16 LGYT2A22 LGYT2A32

15
Functions and technical data www.se.com

Mureva Enclosures
Enclosures for socket Outlets
Offer (B): 750°C, KnockOut entries, with Earth Terminal Blocks

Enclosures offering: Description


b a zone for industrial or domestic socket Outlets,
buttons or indicator lights. Enclosures for Socket Outlets
b a row for modular enclosures protecting socket b Mini Enclosures and Enclosure allowing direct mount of IEC Panel Industrial
Outlets. sockets 16-32A, straight and angled.
b Enclosure with big opening for interlock Switched socket outlets and related
13156M_Image.eps
13162M_Image.eps

protection on DIN.
b Earth terminal included and mounted.

13151M_Image.eps
Technical data
Enclosures
In conformity with standards Empty enclosures IEC 60670-1 and 24
Equipped switchboards IEC 61439-1 and 3
Enclosure colour Light grey RAL 7035 and transparent green wicket gate
Degree of protection IP IP65 (as per IEC 60529)
IK IK09 (as per IEC 62262)
Enclosure and mini enclosure for socket Outlets. Insulating Class 2

Additional characteristics
Operating temperature -25°C to +60°C
Flame and abnormal heat resistance: 750°C as per IEC 60695-2-11
Resistance to chemicals and atmospherics agents, UVs
Optional locking of the door, sealing of the front face and front plates

Enclosure catalogue numbers


Technical data Accessories delivered with an enclosure cat. no. (2) Cat. no.
Total Open Dimensions Pre-cutout (1)
(top and bottom) Wiring class II Terminal Terminal Plates for:
mod. (mm) strap plugs in all block block buttons, 65 x 85 90 x 100
enclosures support number of indicator mm mm
hole lights power socket
E = Earth outlets Outlets
M 16 20 25 32 50 terminal
(Type LGYT2Axx)
W H D PG 11 16 21 29/36 4 8 16 13138 13135 13137
Mini enclosures for power outlets (65 x 85 mm openings)
4 1 98 248 98.5 - - 1 - - - 1 - 1E - - - - - 13150M
1 98 310 98.5 - - 1 - - - 1 - 1E - - - 1 - 13151M
- 98 392 98.5 - - 1 - - - 1 - 1E - - - 1 - 13152M
Enclosures for power outlets (90 x 100 mm openings)
5 2 138 460 160 - 1 1 1 - - 1 - 1E - - 1 - - 13153M
8 4 236 460 160 - 2 2 3 - 1 1 1 - 1E - 1 - - 13154M
12 3 340 460 160 6 6 2 3 - 1 1 1 - 1E - 1 - - 13155M
6 340 460 160 6 6 2 3 - 1 1 1 - 1E - 2 - - 13156M
18 8 448 460 160 - 10 4 2 - 1 1 1 - - 1E 2 - - 13157M
Enclosures for interlocked power outlets (103 x 225 mm openings)
5 1 138 460 160 - 1 1 1 - - 1 1 1E - - - - - 13160M
12 3 340 460 160 6 6 2 3 - 1 1 1 - 1E - - - - 13162M
18 4 448 460 160 - 10 4 2 1 1 1 1 - 1E - - - - 13163M
(1) Concentric pre-cutouts of the PG and ISO/metric type (EN 50262).
(2) Accessories also delivered:
b mini enclosures: class II plugs.
b enclosures: class II plugs, blanking plates (5 modules of 18 mm per row) and a marking kit.

16
Functions and technical data www.se.com

Mureva Enclosures
Polyvalent Enclosures and Interface modules
Offer (B): 750°C, KnockOut entries

The opaque door polyvalent enclosure provides a zone Description


to install non-modular enclosures.
The polyvalent enclosure for socket Outlets provides Polyvalent Enclosures with Plain door
a row for modular enclosures and a universal zone. b Delivered with a slotted mounting plate to be mounted at the back.
b Available depth for installation of non-Modular circuit breakers on slotted plate:
13168M_Image.eps
13170M_Image.eps

130 mm.
b Reversible front face to change door opening direction.

Polyvalent enclosures with smooth front face


b Flexible solution to allow mounting of any device on front empty face throughout
drilling.
b Internal space till 100mm for tranfo or other devices to keep protected.

Interface modules enclosure


Polyvalent Mureva enclosure.
b This modules can be used to mount external pushbutton or can also act as cables
duct.
Enclosures that can be installed alone,
but also as an extension of another enclosure.
13973M_Image.eps

Technical data
Mureva switchboards guarantee a high degree of protection and increased
dependability.
Enclosures
In conformity with standards Empty enclosures IEC 60670-1 and 24
Equipped switchboards IEC 61439-1 and 3
Enclosure colour Light grey RAL 7035
Degree of protection IP IP65 (as per IEC 60529)
IK IK09 (as per IEC 62262)
Insulating Class 2

Additional characteristics
Operating temperature -25°C to +60°C
Flame and abnormal heat resistance: 750°C as per IEC 60695-2-11
Resistance to chemicals and atmospherics agents, UVs
Optional locking of the door, sealing of the front face and front plates
Note: Polyvalent enclosures with smooth face can accomodate socket outlet till 63A (drilling the
surface).

Enclosure catalogue numbers


Technical data
Mureva interface enclosure.
Accessories with an enclosure cat. no. (2) Cat. no.
Nb of Dimensions (mm) Pre-cutout (top and bottom) (1) Wiring class II plugs Plates for:
op. strap in all enclosures buttons, indicator 65 x 85 mm 90 x 100 mm
lights socket Outlets socket Outlets
M 16 20 25 32 50
W H D PG 11 16 21 29/36 13138 13135 13137
Polyvalent Mureva
Polyvalent Enclosures with Plain door
- 340 460 160 6 6 2 3 - - 1 - - - 13170M
- - 610 160 6 6 2 3 - - 1 - - - 13171M
- 448 460 160 - 10 4 2 1 - 1 - - - 13172M
- - 610 160 - 10 4 2 1 - 1 - - - 13173M
Polyvalent enclosures with smooth face
5 138 460 160 - 1 1 1 - - 1 - - - 13164M
8 236 460 160 - 2 2 3 - 1 1 - - - 13165M
12 340 460 160 6 6 2 3 - 1 1 - - - 13166M
12 460 160 6 6 2 3 - 1 1 - - - 13167M
18 448 460 160 - 10 4 2 1 1 1 - - - 13168M
Interface modules enclosures
1 138 460 160 - 1 1 1 - - 1 3 - 1 13973M
2 138 610 160 - 1 1 1 - - 1 4 - 1 13974M
(1) Concentric pre-cutouts of the PG and ISO/metric type (EN 50262).
(2) Accessories also delivered: class II plugs and blanking plates (5 modules of 18 mm per row)
b mini enclosures: class II plugs.
b enclosures: class II plugs, blanking plates (5 modules of 18 mm per row) and a marking kit.

17
Functions and technical data www.se.com

Mureva Enclosures
Modular and mini enclosures, enclosures with interface
Offer (C): 650°C, Smooth entries

3 to 12 module mini enclosures. Description


12 to 72 module enclosures.
Modular Enclosure
10342_Image.eps

b Reversible front face to allow right or left door opening.


b Adjustable DIN rail interdistance to (125-150-175 mm), with 2 possible depth
adaptations.
b Extractable chassis and different terminal possible installations.
b Equipped with Earth Terminal Blocks already mounted on support.
b Ergonomic handle equippable with keylock.
10314_Image.eps

Mini enclosure
b Embedded door to minimize dimensions, equippabel with keylock.
b Possibility to insert terminals directly on dovetail on bottom Enclosures.
Mureva enclosures and mini enclosures for Modular circuit
breakers.
Modular Enclosure with interface
b Propose an external interface on the right or left zone available to accommodate
10352_Image.eps

buttons, indicator lights or socket outlets.


b Keeping a protected zone with din rail behind the door, to install modular circuit
breakers.
b Lateral flexible space for installation of non modular devices with 100 mm max
depth.

Technical data
Enclosures
In conformity with standards Empty enclosures IEC 60670-1 and 24
Equipped switchboards IEC 61439-1 and 3
Enclosure colour Light grey RAL 7035 and transparent green door
Degree of protection IP IP65 (as per IEC 60529)
IK IK09 (as per IEC 62262)
Mureva enclosure for Modular circuit breakers with interface.
Insulating Class 2

Additional characteristics
Operating temperature -25°C to +60°C
Flame and abnormal heat resistance: 650°C as per IEC 60695-2-11
Resistance to chemicals and atmospherics agents, ISO 4892-2
UV resistance according to
Optional locking of the door, sealing of the front face and front Keylock
plates

18
Functions and technical data www.se.com

Mureva Enclosures
Modular and mini enclosures, enclosures with interface
Offer (C): 650°C, Smooth entries

Enclosure catalogue numbers


Technical data Accessories delivered with an enclosure cat. no. (2) Cat. no.
Row Total Slot Pre-cutout (top and bottom) (1) Dimensions Marking Wiring class II Plates cat. no.:
mod. for M 16 20 20 25 32 50 (mm) kit strap plugs in all buttons, 65 x 85 mm 90 x 100 mm
plate enclosures indicator lights outlets outlets
PG 11 16 21 29/36 W H D 13138 13135 13137
Mini enclosures
1 3 - - - 1 - - 80 150 98 - - 1 - - - 10311
4 1 1 - 1 - - 123 200 112 - - 1 - - - 10312
6 1 1 - 1 - - 159 200 112 - - 1 - - - 10313
8 2 2 - 1 - - 195 200 112 - - 1 - - - 10314
12 2 2 - 2 1 - 267 200 112 - - 1 - - - 10315
Modular Enclosures
1 12 6 - 6 2 3 - 340 280 160 - 1 1 - - - 10340
18 - - 10 4 2 1 448 280 160 - 1 1 - - - 10341
2 24 6 - 6 2 3 - 340 460 160 - 1 1 - - - 10342
36 - - 10 4 2 1 448 460 160 - 1 1 - - - 10343
3 36 6 - 6 2 3 - 340 610 160 - 2 1 - - - 10344
54 - - 10 4 2 1 448 610 160 - 2 1 - - - 10345
4 72 - - 10 4 2 1 448 842 160 - 3 1 - - - 10346
Modular with interface
2 24 3 - - 10 4 2 1 448 460 160 2 1 1 3 - - 10351
3 36 4 - - 10 4 2 1 448 610 160 3 2 1 4 - - 10352
(2) Accessories also delivered:
b mini enclosures: class II plugs.
b enclosures: class II plugs, blanking plates (5 modules of 18 mm per row).

Terminal block components Cat. no.


These components can be used to implement and install a terminal block:
b on the chassis near the conductor entry
LGYT2A04.eps

LGYT2A08.eps
LGYT4A01.eps

b on a DIN rail mounted on the enclosure chassis


b in the Prisma Plus switchboards on the functional uprights
LGYT4A01
Terminal block junction
Compact associable terminal block junction kit Batch of 10 - LGYT4A01
LGYT2A04 LGYT2A08 Screw insulated terminal block
2 x 16v + 2 x 10v screw terminal block
LGYT2A16.eps

- LGYT2A04
+ 1 green and 1 blue covers (80 A) (3)
4 x 16v + 4 x 10v screw terminal block
- LGYT2A08
+ 1 green and 1 blue covers (80 A) (3) (4)
8 x 16v + 8 x 10v screw terminal block
- LGYT2A16
+ 1 green and 1 blue covers (80 A) (3)
11 x 16v + 11 x 10v screw terminal block
LGYT2A16 - LGYT2A22
+ 1 green and 1 blue covers (80 A) (3)
16 x 16v + 16 x 10v screw terminal block
LGYT2A22.eps

- LGYT2A32
+ 1 green and 1 blue covers (80 A) (3)

Everything for the interface

Direct mounting With plate With plate With plate


LGYT2A22
cat. no. 13136 cat. no. 13137 cat. no. 13138
A B C D
LGYT2A32.eps

16/32 A slanting Domestic and LV LV and ELV socket Buttons, indicator


socket Outlets power oultets Outlets (65 x 65 mm lights and switches
(90 x 100 mm). (65 x 85 mm). and 75 x 75 mm). 16 and 22 mm diameter.
LGYT2A32

19
Functions and technical data www.se.com

Mureva Enclosures
Polyvalent Enclosures and Interface modules
Offer (C): 650°C, KnockOut entries

The opaque door polyvalent enclosure provides a zone Description


to install non-Modular circuit breakers.
The polyvalent enclosure for socket Outlets provides Opaque door polyvalent enclosure
a row for Modular circuit breakers and a universal b Delivered with a slotted mounting plate mounted at the back.
zone. b Available depth for installation of non-Modular circuit breakers on mounting plate:
130 mm.
10381_Image.eps

b Reversible front face to change door opening direction.


10378_Image.eps

Interface modules enclosure


b This enclosure can also act as a cable duct.
b In enclosures with 3 or 4 openings, the kit for INS40/63/80 A must be mounted
in the central openings.

Technical data
Mureva switchboards guarantee a high degree of protection and increased
dependability.
Polyvalent Mureva Polyvalent Mureva enclosures
enclosures with plain door. with smooth front face. Enclosures
In conformity with standards Empty enclosures IEC 60670-1 and 24
Equipped switchboards IEC 61439-1 and 3
Enclosure colour Light grey RAL 7035
Degree of protection IP IP65 (as per IEC 60529)
IK IK09 (as per IEC 62262)
Insulating Class 2

Additional characteristics
Operating temperature -25°C to +60°C
Flame and abnormal heat resistance: 650°C as per IEC 60695-2-11
Resistance to chemicals and atmospherics agents, UVs
Optional locking of the door, sealing of the front face and front plates
Note:
b polyvalent enclosures for socket Outlets can accommodate socket Outlets up to 125 A.
b polyvalent enclosures with smooth face can accomodate socket outlet till 63A (drilling the
surface).

Enclosure catalogue numbers


Technical data Accessories delivered with an enclosure cat. no. (2) Cat. no.
Nb of Dimensions (mm) Nb of Pre-cutout (top and bottom) (1) Wiring class II plugs Plates cat. no.:
op. mod. M 16 20 25 32 50 strap in all buttons, 65 x 85 mm 90 x 100
enclosures indicator outlets mm
lights outlets
W H D PG 11 16 21 29/36 13138 13135 13137
Polyvalent Mureva
Opaque door polyvalent enclosures
- 340 460 160 - 6 6 2 3 - - 1 - - - 10380
- - 610 160 - 6 6 2 3 - - 1 - - - 10381
- 448 460 160 - - 10 4 2 1 - 1 - - - 10382
Polyvalent enclosure for socket outlets
- 138 460 160 5 - 1 1 1 1 - 1 - - - 10374
- 236 460 160 8 - 2 2 3 3 1 1 - - - 10375
- 340 335 160 12+1 6 6 2 3 3 1 1 - - - 10376
- - 460 160 12+1 6 6 2 3 3 1 1 - - - 10377
- 448 460 160 18+1 - 10 4 2 2 1 1 - - - 10378
(1) Concentric pre-cutouts of the PG and ISO/metric type (EN 50262).
(2) Accessories also delivered:
b opaque door polyvalent enclosures: class II plugs, mounting plate.
b polyvalent enclosures for socket outlets: class II plugs, blanking plates (5 modules of 18 mm) and marking kit.

20
Functions and technical data www.se.com

Mureva Enclosures
Enclosures for socket outlets
Offer (C): 650°C, KnockOut entries, without Terminal Blocks

Enclosures offering: Technical data


b a zone for industrial or domestic socket Outlets, Mureva switchboards guarantee a high degree of protection and increased
buttons or indicator lights. dependability.
b a row for Modular circuit breakers protecting
socket Outlets. Enclosures
In conformity with standards Empty enclosures IEC 60670-1 and 24
Equipped switchboards IEC 61439-1 and 3
10366_Image.eps
10371_Image.eps

Enclosure colour Light grey RAL 7035 and transparent green wicket gate
Degree of protection IP IP65 (as per IEC 60529)
IK IK09 (as per IEC 62262)
Insulating Class 2
10361_Image.eps
Additional characteristics
Operating temperature -25°C to +60°C
Flame and abnormal heat resistance: 650°C as per IEC 60695-2-11
Resistance to chemicals and atmospherics agents, UVs
Optional locking of the door, sealing of the front face and front plates
Enclosure and mini enclosure for socket Outlets.

Enclosure catalogue numbers


Technical data Accessories delivered with an enclosure cat. no. (2) Cat. no.
Total Open Pre-cutout (top and bottom) (1) Dimensions (mm) Wiring class II Plates cat. no.:
mod. M 16 20 25 32 50 strap plugs in all buttons, 65 x 85 mm 90 x 100
enclosures indicator outlets mm
lights outlets
PG 11 16 21 29/36 W H D 13138 13135 13137
Mini enclosures for socket outlets (65 x 85 mm openings)
4 1 - - 1 - - 98 248 98.5 - 1 - - - 10360
2 - - 1 - - 98 310 98.5 - 1 - 1 - 10361
3 - - 1 - - 98 392 98.5 - 1 - 1 - 10362
Enclosures for socket outlets (90 x 100 mm openings)
5 2 - 1 1 1 - 138 460 160 - 1 - - 1 10363
8 4 - 2 2 3 - 236 460 160 1 1 - - 1 10364
12 3 6 6 2 3 - 340 335 160 1 1 - - 1 10365
6 6 6 2 3 - 340 460 160 1 1 - - 2 10366
18 8 - 10 4 2 1 448 460 160 1 1 - - 2 10367
Enclosures for interlocked socket outlets (103 x 225 mm openings)
5 1 - 1 1 1 - 138 460 160 - 1 - - - 10370
8 2 - 2 2 3 - 236 460 160 1 1 - - - 10371
12 3 6 6 2 3 - 340 460 160 1 1 - - - 10372
18 4 - 10 4 2 1 448 460 160 1 1 - - - 10373
(1) Concentric pre-cutouts of the PG and ISO/metric type (EN 50262).
(2) Accessories also delivered:
b mini enclosures: class II plugs.
b enclosures: class II plugs, blanking plates (5 modules of 18 mm per row) and a marking kit.
Note: flush-mounted socket outlets, see 93145.

21
Accessories www.se.com

Mureva Enclosures
Waterproof enclosures

Catalogue numbers
Name Description Use Cat. no.
Mini Enclosures
enclosures

For enclosure implementation


Wall mounting lugs (set of 4) - - ● ● ● ● ● ● ● 13935
Blanking plate (set of 10 x 5 modules) ● ● ● ● - ● ● ● - 13940
For switchgear implementation
Plate for 85 x 65 slot for 50 x 50 socket Outlets ● - - - - - - - - 13135
Plate for 90 x 100 slot for 65 x 85 socket Outlets - - - ● ● ● - - - 13136
65 x 65 and 75 x 75 socket Outlets - - - ● ● ● - - - 13137
ø 16 and 22 mm pushbutton controls - - - ● ● ● - - - 13138
Plate for 103 x 225 slot for One 85 x 65 + one 90 x 100 slot - - - - - - ● - - 13142
Front plate Plain 12 modules - - ● ● - - - - - 13944
18 modules - - ● - - - - - - 13945
For electrical connection
Terminal block support for mini enclosure 4 modules - ● - - - - - - - 13361
6 modules - ● - - - - - - - 13362
8 modules - ● - - - - - - - 13363
12 modules - ● - - - - - - - 13364
Cable gland PG13.5 ● - - - - - - - - 83993
PG16 ● ● ● ● ● ● ● ● ● 83994
PG21 ● ● ● ● ● ● ● ● ● 83995
For enclosure protection
Keylock ● ● ● ● - ● ● ● ● 13948
Insert Triangle ● ● ● ● - ● ● ● ● 13949
For enclosure maintenance
Front plate 12 modules - - ● ● - - - - ● 10200
18 modules - - ● - - - - - ● 10209
Terminal block components
Compact associable 1 x 6/25v (screw) + 4 x 1.5/4v (push/in) LGYT1E05
- - ● ● - ● ● ● ●
screwless terminal terminal block (63 A) + jumper
blocks / earth 3 x 6/25v (screw) + 11 x 1.5/4v (push/in) LGYT1E14
(Type LGYT1xxx)* - - ● ● - ● ● ● ●
terminal block (63 A) + jumper
3 x 6/25v (screw) + 21 x 1.5/4v (push/in) ● ● ● ● ● LGYT1E24
- - - -
terminal block (63 A) + jumper
1 x 6/25v (screw) + 4 x 1.5/4 v (push/in) ● ● ● ● ● ● LGYT1N05
- - -
terminal block (63 A) + jumper
3 x 6/25v (screw) + 11 x 1.5/4v (push/in) ● ● ● ● ● ● LGYT1N14
- - -
terminal block (63 A) + jumper
3 x 6/25v (screw) + 21 x 1.5/4v (push/in) ● ● ● ● ● ● LGYT1N24
- - -
terminal block (63 A) + jumper
Terminal block Compact associable terminal block LGYT4A01
- - ● ● - ● ● ● ●
junction junction kit Batch of 10
Compact associable 2 x 16v + 2 x 10v screw terminal block LGYT2A04
- ● ● ● ● ● ● ● ●
screw terminal blocks + 1 cover green and 1 cover blue (80A)
/ Neutral 4 x 16v + 4 x 10v screw terminal block LGYT2A08
(Type LGYT2xxx) - - ● ● - ● ● ● ●
+ 1 cover green and 1 cover blue (80A)
8 x 16v + 8 x 10v screw terminal block ● ● ● ● ● ● LGYT2A16
- - -
+ 1 cover green and 1 cover blue (80A)
11 x 16v + 11 x 10v screw terminal block ● ● ● ● ● ● LGYT2A22
- - -
+ 1 cover green and 1 cover blue (80A)
16 x 16v + 16 x 10v screw terminal block ● ● ● ● ● ●
- - - LGYT2A32
+ 1 cover green and 1 cover blue (80A)
Screw insulated 4 x 16v screw terminal block P/N (63 A) - - ● ● - ● ● ● ● R9H13405
terminal block
4 x 16v screw terminal block P/P (63 A) - - ● ● - ● ● ● ● R9H13405P
4 x 16v screw terminal block N/N (63 A) - - ● ● - ● ● ● ● R9H13405N
1 x 35v + 6 x 16v screw terminal block P/N (125 A) - - ● ● - ● ● ● ● R9H13411
1 x 35v + 6 x 16v screw terminal block P/P (125 A) - - ● ● - ● ● ● ● R9H13411P
1 x 35v + 6 x 16v screw terminal block N/N (125 A) - - ● ● - ● ● ● ● R9H13411N
* LGTY1xxx references are only dedicated to the Modular Enclosures: references from 13962M to 13968M.

22
Accessories www.se.com

Mureva Enclosures
Waterproof enclosures

Description
For enclosure implementation Cat. no.
Type Description
Wall mounting lugs Used to fix the enclosure to the wall without using holes in the back of the enclosure 13935
E88346.eps

Plain front plate Used to hide a zone without Modular circuit breakers
12 modules 13944
E88355.eps

18 modules 13945

Blanking plate Clipped onto the front plates to conceal slots with no devices 13940
E88350.eps

For swtichgear implementation Cat. no.


Type Description
Functional plates for 60x85 m m slot Adaptation (screwed-on) for 50 x 50 mm socket Outlets 13135
13135.eps

Functional plates for 90x100 m m slot Adaptation (screwed-on) for 65 x 85 mm socket Outlets 13136
E88351.eps

Blanking or adaptation (screwed on) for 65 x 65 mm or 75 x 75 mm socket Outlets 13137


E88352.eps

(slot to be punched out)

Blanking or adaptation (clipped on) for buttons, indicator lights and switches of 13138
E95165.eps

diameters 16 and 22 mm (1 central slot or 2 side by side to punch out).

Functional plates for 103 x 225 mm slot Adaptation (screwed on) with 2 openings: 65 x 85 mm and 90 x 100 mm 13142
E88354.eps
LGYT2A04.eps

LGYT2A08.eps

LGYT2A16.eps

LGYT2A22.eps

LGYT2A32.eps

LGYT2A04 LGYT2A08 LGYT2A16 LGYT2A22 LGYT2A32

23
Accessories www.se.com

Mureva Enclosures
Waterproof enclosures

Description (cont.)
For electrical connection Cat. no.
Type Description Inclined version
Terminal block support Flat iron (12 x 2 mm), 2 versions: screwed onto
the pins or onto the chassis
Terminal block support for mini enclosure
E88357.eps

4 modules 13361
6 modules 13362
8 modules 13363
12 modules 13364
Terminal block support for enclosure
E88358.eps

Bottom
base
8 modules - 13925
12 modules - 13597
18 modules - 13598
Cable glands Used for cable and tube incoming, guaranteeing tightness and
mechanical withstand
E88362.eps

PG13.5 83993
PG16 83994
PG21 83995

24
Accessories www.se.com

Mureva Enclosures
Waterproof enclosures

Description (cont.)
For enclosure protection Cat. no.
Type Description
Keylock Eurolocks combination no. 850. Installed in the door. 13948
E88367.eps

Insert Installed in the door (male square or triangle, female key supplied)
Triangle 13949
E88368.eps

For enclosure maintenance Cat. no.


Type Description
Front plate 10200
10209

25
Dimensions www.se.com

Mureva Enclosures
Waterproof enclosures

Pre-cutouts
The new European standard EN 50262 generalises metric dimensions for
cable glands.
To simplify the transition, the entire Mureva range is equipped with pre-cutouts both
in ISO/metric standardisation and in PG standardisation. Each pre-cutout is marked:
simple pre-cutout adapted to the metric cable gland:

b double pre-cutout:
v external: pre-cutout adapted to the metric cable gland/ISO.
v internal: pre-cutout adapted to the PG cable gland.

Cable glands
Type of pre-cutout For cables of diameter (mm)
M16 4-8
M20 6 - 12
M25 12 - 18
M32 18 - 25
M50 30 - 38
PG11 5 - 10
PG16 10 - 14
PG21 14 - 17
PG29 19 - 26
PG36 22 - 32

Associations
The enclosures can be associated:
b horizontally, regardless of their height (see diagram below).
b vertically, if their width is identical.
Insertion of cables between the enclosures is possible, while preserving the degree
of protection IP65.
DB123170-LIO.eps

Ø M32

26
Dimensions www.se.com

Mureva Enclosures
Waterproof enclosures

Mini enclosures
Socket Outlets

A B C Weight (g)
DB123172-LIO.eps

E95012.eps

E95013.eps
248 166 41 550
310 228 41 600
392 310 41 700

Modular
3 modules 4 and 6 modules 8 and 12 modules
E94100.eps

DB123173-LIO.eps

new_schema.eps
Number
Weight
of A L
(g)
modules
3 - 80 300
4 - 123 500
6 - 159 650
8 88 195 850
12 160 267 1050

3 modules 4 and 6 modules 8 and 12 modules


DB123174-LIO.eps

DB123175-LIO.eps

DB123176-LIO.eps

3 modules 4 modules 6 modules


DB123177-LIO.eps

DB123178-LIO.eps

DB123179-LIO.eps

8 modules 12 modules
DB123180-LIO.eps

DB123181-LIO.eps

27
Dimensions www.se.com

Mureva Enclosures
Waterproof enclosures

Enclosures
5 modules

A B C Weight (g)
DB123182-LIO.eps

DB123183-LIO.eps

DB123184-LIO.eps
460 251 104.5 1450
460 251 104.5 1250
460 251 104.5 1400
460 251 104.5 1400
610 490 60 1650
DB123185-LIO.eps

(*) pre-punchout also used for enclosure association


8 modules

A B C Weight (g)
DB123186-LIO.eps

DB123187-LIO.eps

460 251 104.5 2050


460 251 104.5 1900
460 251 104.5 1900
DB123188-LIO.eps

(*) pre-punchout also used for enclosure association

28
Dimensions www.se.com

Mureva Enclosures
Waterproof enclosures

Enclosures
12-13 modules

A B C Weight (g)
DB123189-LIO.eps

DB123190-LIO.eps

DB123191-LIO.eps
280 118 81 1900
335 170 82.5 2200
335 170 82.5 2150
460 251 104.5 3100
460 251 104.5 2850
460 251 104.5 3300
460 251 104.5 2650
460 251 104.5 2700
610 401 104.5 4100
460 251 104.5 4550
DB123192-LIO.eps

(*) pre-punchout also used for enclosure association


18-19 modules

A B C Weight (g)
DB123193-LIO.eps

DB123195-LIO.eps

DB123194-LIO.eps

280 118 81 2400


280 118 81 1950
460 251 104.5 3850
460 251 104.5 3550
460 251 104.5 4150
460 251 104.5 3200
460 251 104.5 3150
460 251 104.5 3300
610 401 104.5 3150
610 401 104.5 5600
610 401 104.5 4050
842 633 104.5 6500
842 633 104.5 6600
DB123196.eps

(*) pre-punchout also used for enclosure association

29
Index www.se.com

Mureva Enclosures
Waterproof enclosures

Code Page Code Page Code Page


10000 13178............................. 13 13985............................... 9
13179............................. 13 13986............................... 9
10200....................... 22, 25 13180............................. 13 13987............................... 9
10209....................... 22, 25 13181............................. 13 13990............................... 9
10311............................. 19 13182............................. 13 13991............................... 9
10312............................. 19 13185............................. 13 13992............................... 9
10313............................. 19 13186............................. 13 13993............................. 12
10314............................. 19 13187............................. 13 13994............................. 12
10315............................. 19 13188............................. 13
13189............................. 12 83000
10340............................. 19
10341............................. 19 13190............................. 12
13191............................. 12 83993....................... 22, 24
10342............................. 19
13192............................. 12 83994....................... 22, 24
10343............................. 19
13193............................. 12 83995....................... 22, 24
10344............................. 19
10345............................. 19 13195............................. 12 LGYT
10346............................. 19 13197............................. 12
10351............................. 19 13198............................. 12 LGYT1E05................ 15, 22
10352............................. 19 13361....................... 22, 24 LGYT1E14................ 15, 22
10360............................. 21 13362....................... 22, 24 LGYT1E24................ 15, 22
10361............................. 21 13363....................... 22, 24 LGYT1N05................ 15, 22
10362............................. 21 13364....................... 22, 24 LGYT1N14................ 15, 22
10363............................. 21 13431............................. 11 LGYT1N24................ 15, 22
10364............................. 21 13432............................. 11 LGYT2A04. 9, 11, 15, 19, 22
10365............................. 21 13433............................. 11 LGYT2A08. 9, 11, 15, 19, 22
10366............................. 21 13434............................. 11 LGYT2A16. 9, 11, 15, 19, 22
10367............................. 21 13435............................. 11 LGYT2A22. 9, 11, 15, 19, 22
10370............................. 21 13436............................. 11 LGYT2A32. 9, 11, 15, 19, 22
10371............................. 21 13437............................. 11 LGYT4A01. 9, 11, 15, 19, 22
10372............................. 21 13439............................. 11
10373............................. 21 13440............................. 11 R9H13
10374............................. 20 13441............................. 11
10375............................. 20 13442............................. 11 R9H13405...................... 22
10376............................. 20 13443............................. 11 R9H13405N.................... 22
10377............................. 20 13444............................. 11 R9H13405P.................... 22
10378............................. 20 13597............................. 24 R9H13411...................... 22
10380............................. 20 13598............................. 24 R9H13411N.................... 22
10381............................. 20 13925............................. 24 R9H13411P.................... 22
10382............................. 20 13935....................... 22, 23
13940....................... 22, 23
13000 13944....................... 22, 23
13945....................... 22, 23
13135....................... 22, 23 13948....................... 22, 25
13136. 9, 10, 14, 19, 22, 23 13949....................... 22, 25
13137. 9, 10, 14, 19, 22, 23 13956M........................... 15
13138. 9, 10, 14, 19, 22, 23 13957M........................... 15
13142....................... 22, 23 13958M........................... 15
13150M........................... 16 13959M........................... 15
13151M........................... 16 13960M........................... 15
13152M........................... 16 13962M........................... 15
13153M........................... 16 13963M........................... 15
13154M........................... 16 13964M........................... 15
13155M........................... 16 13965M........................... 15
13156M........................... 16 13966M........................... 15
13157M........................... 16 13967M........................... 15
13160M........................... 16 13968M........................... 15
13162M........................... 16 13970M........................... 15
13163M........................... 16 13971M........................... 15
13164M........................... 17 13972M........................... 15
13165M........................... 17 13973M........................... 17
13166M........................... 17 13974M........................... 17
13167M........................... 17 13975............................... 9
13168M........................... 17 13976............................... 9
13170M........................... 17 13977............................... 9
13171M........................... 17 13978............................... 9
13172M........................... 17 13979............................... 9
13173M........................... 17 13981............................... 9
13175............................. 13 13982............................... 9
13176............................. 13 13983............................... 9
13177............................. 13 13984............................... 9

30
Notes www.se.com

31
Schneider Electric SE

35, rue Joseph Monier


CS 30323
92506 Rueil Malmaison Cedex
France

RCS Nanterre 542 048 574


Capital social 2 291 343 536 €
www.se.com

11/2023
Document Number CU906000

© 2023 - Schneider Electric. All Rights Reserved. This document has been
All trademarks are owned by Schneider Electric SE or its affiliated companies. printed on recycled paper

You might also like