KCN-S/KCN-W: Merits
KCN-S/KCN-W: Merits
10mm flashes.
13mm
darkness.
All 16 models include advanced functions such as
prescaling and decimal display. These models can be
combined appropriate to satisfy your requirements.
Multifunction
KCX
Timer option
Keypad protection cover The KCN-4S general purpose 4-digit counter can be used
A keypad cover is attached to prevent erroneous operation. also as a precise digital timer.
KCH-B
AC power is 90 mm thick
B-32
KCN-S/KCN-W
Electronic
Counters
Mode options
KCN-A
increments by one for each pulse
Count
KCN-A
0 Pulse input
Subtraction mode
In the Subtraction mode, the Preset value
count decrements by one for
Count
Decremented
KCN-S/W
each pulse input. When the
to 10
value has reached zero, the MODE
counter generates a signal. RST ENT
Sensor
0 Pulse input
KCN-B
Addition and Subtraction
Counting operation is not affected by any deviation of roller movement. Addition pulse and subtraction pulse can be
entered separately or simultaneously.
KCN-T
Roller for length Addition
measurement
Subtration
MODE
Deviation RST ENT MODE
RST ENT
Rotary encoder
KCY
Two-phase signal
Prescaling
KCX
Converting the number of pulses to quantity or dimension
Quantity
KCX-RN
Multiplied by 4
MODE
Sensor RST ENT Prescaled at 4
MODE
B-33
KCN-S/KCN-W
Electronic
Counters
Decimal point
MODE
RST ENT
KCN-A
Relay
KCN-B
Proximity switch
KCN-T
Relay output
Photoelectric sensor
KCN- R
KCY
DC output
KCN- T
Rotary encoder
KCX
KCX-RN
Addition
(Mode 7)
OUT1
Subtration
Photoelectic Photoelectic C P1
MODE
sensor at entry sensor at exit
KCM
RST ENT
Conveyor
The counter counts and displays the number of workpieces on the conveyor.
The count is added to by input pulse generated by the photoelectric sensor
at the entry, and subtracted from by pulse generated by another sensor at
the exit. Addition and subtraction can occur at the same time.
B-34
KCN-S/KCN-W
Electronic
Counters
Timer option KCN-4SR-C/4ST-C/4SR/4ST General Purpose 4-digit Counters
These counters can be used also as timers from 0.01 second to 99 hours and 59 minutes
KCN-A
KCN-A
1m 99m59s 99h59m
KCN-S/W
KCN-B
Digital clock for easy Five output modes for
and error-free setting wide applications
KCN-T
On Delay
Off Delay
Quartz crystal oscillator
One Shot
assures the clock precision.
Flicker
Accumulate
KCY
KCX
Either time elapsed or remaining can be displayed.
KCX-RN
KCH-B
KCM
B-35
KCN-S/KCN-W Counter/Timer Functions
Electronic
Counters
Relay
KCN-A
Multifunction
Single or Dual preset setting, nine modes including One-Shot, Hold and
Compare output, prescaling and decimal point display
General Specifications
Item General Purpose Multifunction
Sensor AC DC 24V (20 28V) 15mA (Max. 10 p-p ripple) DC24V (20 28V) 60mA (Max. 10 p-p ripple)
power DC None None
Memory backup at power failure EEPROM (Up to 100,000 writes)
Ambient temperature 10 50
Storage temperature 25 70 (with no freezing)
KCH-B
Shock resistance Durable for 11 ms along three axes at 490 m/s2 (50 G) No error for 11 ms along three axes at 98 m/s2 (10 G)
Noise resistance 1.5 kV between power terminals (square wave pulse with 1 s width and 1 ns rise time)
Coating IP64 for the keypad on the front panel against dust and splash.
Installation Flush mounting
Connection Terminal block
AC Approx. 220 g Approx. 150 g
Mass
DC Approx. 110 g Approx. 110 g
Noise tests also include static discharge test and NEMA compliance tests.
B-36
Counter Functions KCN-S/KCN-W
Electronic
Counters
Performance Specification
Item General Purpose (KCN-S) Multifunction (KCN-W)
Operation Addition and subtration
Setting Single preset Single or Dual prest (selected by keys)
Number of digits 4 or 6 digits (depending on models)
Setting range 4 digits: 999 9999 6 digits: 99999 999999
KCN-A
Counting speed 30cps, 1kcps, 2kcps, or 5kcps (selected by keys) For duty factors, see Counting Timing.
Input mode Addition and/or subtraction or two-phase (selected by keys)
Input logic Positive (voltage) or negative (no voltage) (selected by keys)
Extermal reset input Minimum pulse width: 5 ms
KCN-A
Auto reset Responded within 0.5 ms (2.5 ms at 5kcps)
Manual reset Responded within 0.1 s
Power reset Power shutdown: 1 s or more Reset duration: 1 s or less (until restart)
Output NPN open collector or relay contact 1a (depending on models)
KCN-S/W
One Shot (momentary output) or Hold One Shot (momentary output), Hold or Compare
Output mode (selected by keys) (selected by keys)
Output duration 0 9990 ms (selected by keys in 10 ms increments)
Maximum counting speed Open collector output Relay output
KCN-B
30cps 14ms or less 19ms or less
I/O response 1kcps 1ms or less 6ms or less
2kcps 0.5ms or less 5.5ms or less
5kcps 2.5ms or less 7.5ms or less
KCN-T
Decimal point display Any location (selected by keys)
Prescaling 4 ditits: 0.001 9.999 6 ditits: 0.001 99.999
Count disable input Not available Responded within 2.5 ms
Output response delays only at 5k cps.
KCY
I/O Specifications
Input speed 30cps/ 1kcps/ 2kcps/ 5kcps
Positive: 15k
KCX
Pulse Input resistance Negative: 3.3k (1.8k for DC models)
input
L 0 3V
Input voltage
H 7 30V
On delay: Max. 5ms
Input response
KCX-RN
Off delay: Max. 5ms
Reset Positive: 15k
Input resistance
input Negative: 3.3k (1.8k for DC models)
L 0 3V
Input voltage
H 7 30V
KCH-B
B-37
KCN-S/KCN-W Counter Functions
Electronic
Counters
Output modes
KCN-S KCN-W (dual preset mode)
Mode No Count Signal output OUT1 OUT2
Mode No
1 Continued Held Count Signal output Count Signal output
One shot 1 Continued Held
2 Reset
10 9990ms
2 Reset One shot*
Held
10 9990ms
KCN-W (single preset mode) 3
KCV
Continued
Continued
Mode No Count Signal output 4 Held
Held
1 Continued Held 5 One shot Continued
6 10 9990ms Reset One shot*
2 Reset One shot*
KCN-A
3 Continued 10 9990ms 7 C P2
C P1
4 Held Held 8 C P2
7 C P 9 C P1 P1 C P2
SET SET
0 0
KCY
Reset Reset
OUT OUT
One Shot means signal output for short duration from 10 to 9990 ms
KCX
SET2 SET2
SET1 SET1
0 0
Reset Reset
KCM
OUT1 OUT1
OUT2 OUT2
B-38
Counter Functions KCN-S/KCN-W
Electronic
Counters
Mode 3 OUT2: One Shot Count: Continued Mode 4 OUT2: Held Count: Continued
OUT1: Held OUT1: Held
Addition Subtraction Addition Subtraction
SET2 SET2
SET1 SET1
0 0
Reset Reset
KCN-A
OUT1 OUT1
OUT2 OUT2
Mode 5 OUT2: Held Count: Continued Mode 6 OUT2: One Shot Count: Reset
KCN-A
OUT1: One Shot OUT1: One Shot
Addition Subtraction Addition Subtraction
SET2 SET2
SET1 SET1
KCN-S/W
0 0
Reset Reset
OUT1 OUT1
OUT2 OUT2
KCN-B
Mode 7 OUT2: When the count is equal to or smaller than Mode 8 OUT2: When the count is equal to or larger than
SET2. SET2.
SET2 SET2
KCN-T
SET1 SET1
0 0
OUT1 OUT1
OUT2 OUT2
KCY
Mode9 OUT2: When the count is equal to or larger than
SET1, and when it is equal to or smaller than
SET2.
KCX
SET2
SET1
0
KCX-RN
OUT1
OUT2
KCH-B
In One Shot mode, another countup causes signal output for a set duration.
In Mode 2 Mode 6 , counting at 5k cps is interrupted for 0.5 to 2.5 ms between countup and next pulse input.
B-39
KCN-S/KCN-W Counter Functions
Electronic
Counters
Counting timing
Addition and Subtraction mode
Positive (voltage) input
Addition Subtraction
"H"
INA Pulse can be counted either at rising
"L" edge or falling edge.
KCV
"H"
INB Pulse can be counted either at rising
edge or falling edge. "L"
KCN-A
"H"
INB Pulse can be counted either at rising
edge or falling edge. "L"
Two-Phase mode
Addition Subtraction
"H" "H"
KCN-T
INA
"L" "L"
"H" "H"
INB
"L" "L"
KCY
Duty factors
INA and INB in Two-Phase mode: 50 at 5kcps
KCX
T (200 s)
"H"
INA
KCX-RN
"L"
"H"
INB
"L"
KCH-B
T T T T
4 4 4 4
(50 s or more ) (50 s or more ) Minimum width that
enables counting.
1
Counting speed (cps) (s)
T
KCM
B-40
Counter Functions KCN-S/KCN-W
Electronic
Counters
Wiring Diagrams
General purpose (KCN-S) Multifunction (KCN-W)
KCN-4 6SR KCN-4 6WR
Sensor power Sensor power Sensor Count
DC24V Sensor power DC24V power disable input
15mA IN-A IN - B 0V 60mA IN-A IN-B 0V INH
KCN-A
R Reset input R Reset input
AC AC OUT1 AC100V
KCN-A
100V 200V Relay output 1 240V
OUT OUT2
Relay output Relay output2
KCN-S/W
Sensor power Sensor power Sensor Count
DC24V Sensor power DC24V power disable input
15mA IN-A IN - B 0V 60mA IN-A IN-B 0V INH
KCN-B
OUT1
DC output 1
AC AC AC100V
100V 200V 240V
OUT 0V OUT2 0V
KCN-T
DC output Common output DC output 2 Common output
KCY
R Reset input R Reset input
KCX
OUT1
Relay output 1
OUT OUT2
Relay output DC power DC24V Relay output2 DC power DC12 24V
KCX-RN
KCN-4 6ST-C KCN-4 6WT-C
Common Count
Common input input disable input
IN-A IN - B 0V IN-A IN-B 0V INH
KCH-B
OUT1
DC output 1
KCM
OUT 0V OUT2 0V
DC output Common output DC power DC24V DC output 2 Common output DC power DC12 24V
Dimensions of
6.3
Terminal Block
Wire section: 0.25 to 1.65mm2
8.5
10.55
5.2
7.62 M3 screw
B-41
KCN-S/KCN-W Counter Functions
Electronic
Counters
5V 5V
9 9
3.3k 3.3k
IN A 3 10 IN A 3 10
15k 15k
KCN-A
OUT2 OUT2
5V 11 5V 11
3.3k 3.3k
IN B 4 IN B 4
KCN-S/W
15k 15k
8 OUT1 8 OUT1
5V 5V
3.3k 3.3k
7 7
KCN-B
Reset Reset
15k 15k
10 OUT2 10 OUT2
5V 5V
3.3k 3.3k
KCN-T
Count Count
6 6
disable 15k disable 15k
input input
0V 5 11 0V 0V 5 11 0V
Input logic: Positive (voltege) input (pos) Input logic: Negative (no voltage) input (neg)
Input mode: Addition and Subtraction separate inputs (ad. sb.) Input mode: Addition and Subtraction separate inputs (ad. sb.)
Brown Brown
(Red) (Red)
2 24V sensor power
KCX-RN
Subtraction
(White) (White)
4 IN B 4 IN B
Black Black
(White) (White)
7 Reset 7 Reset
KCM
Black Black
(White) (White)
6 Count disable input 6 Count disable input
Blue Blue
(Black) (Black)
5 0V 5 0V
B-42
Counter Functions KCN-S/KCN-W
Electronic
Counters
DC 2-wire proximity switch Rotary encoder
Input logic: Negative (no voltage) input (neg) Input logic: Positive or negative to be set according to encoder output
Input mode: Addition and Subtraction separate inputs (ad. sb.) Input mode: Two-phase (quad)
KCN-A
Addition
White
3 IN A Green
(Blue)
Black 3 IN A
Subtraction
4 IN B
KCN-A
4 IN B
White
7 Reset
5 0V
Black
KCN-S/W
6 Count disable inpurt
5 0V
KCN-B
20V or more is required for multifunction DC source voltage. TRD-GK -RZ R
Switch or relay
Input logic: Positive (voltage) input (pos) Input logic: Negative (no voltage) input (neg)
Input mode: Addition and Subtraction separate inputs (ad. sb.) Input mode: Addition and Subtraction separate inputs (ad. sb.)
KCN-T
Counting speed: 30cps Counting speed: 30cps
Addition Addition
3 IN A 3 IN A
KCY
Subtraction Subtraction
4 IN B 4 IN B
KCX
7 Reset 7 Reset
5 0V 5 0V
10 Load
OUT2
0V 11
11
Load power
rated at 24 V
B-43
KCN-S/KCN-W Counter Functions
Electronic
Counters
Count (zero-suppressed)
Character height: 13 mm for 4-digit display
10 mm for 6-digit display
Initial settings are displayed in the Setup mode.
KCV
KCN-A
Preset value
KCN-S/W
Output status
OUT1: First preset output
OUT2: Second preset output Measurement unit
Hz: counts per second
KCN-B
B-44
Counter Functions KCN-S/KCN-W
Electronic
Counters
Operating procedures
1. KCN-S General purpose counters
Switching between Setup mode and Run mode
Power on Run mode Setup mode
Press the MODE key and the key at the same time for at least
KCN-A
0.5 second.
Press the MODE key and the key at the same time for at least *
Prescale Select digit: 0 1. 0 0 0
0.5 second, or leave the system in the Setup mode for one minute.
scale
Changing a preset value
Go to the Run mode screen, and change the value as Setting at 0"
KCN-A
cannot be made.
Select digit
MODE
Select number
KCN-S/W
Select new value 0 1 2 3 4 5 6 7 8 9
0 1 2 3 4 5 6 7 8 9 (-)
KCN-B
decimal point is set.
follows:
Initializing the counter
Select decimal point setting mode
MODE
Counting speed Select counting speed
speed Select decimal point position
*
KCN-T
MODE 5 0 0 0 2 0 0 0 1 0 0 0 3 0
(CPS)
.n .n .n .n .n .n
Input mode Select input mode
in Reset key mode Select reset key mode
*
MODE q u a d a .
d s .
b
(two-phase) (addition or subtraction) reset
KCY
MODE *
e n a b d i s a
(enable reset key) (disable reset key)
Count memory Select count memory
count
c l e r
*
r e t n Notes:
MODE (power-on reset) (memory backup)
1. After you change a current setting, always press the ENT key to
KCX
store the new value.
Operation mode Select operation mode
2. indicates a value set at delivery.
c-dtr
* 3. After you change an initial setting, always press the RST key to
MODE u p d n
(addition) (subtraction) reset the count. KCX-RN
4. The displayed count is determined by the prescale and the
Input logic Select input logic
decimal point location. For example, if the prescale is set to
signl 1.200 and the decimal point is set as nnn.nHn, each pulse input
*
MODE p o s n e g increments the count as follows:
positive negative
(voltage input) (no voltage input)
0.012 0.024 0.036 0.048 0.060...
KCH-B
subtraction
out Output duration
Count memory
Backup at Backup at
can be set or The lowest digitI is fixed power failure power failure
changed only in at 0", and cannot be
Output Mode 2. changed. Operation mode Addition
Setting at 0" cannot be
made. Input logic Positive Negative
MODE
Output mode Mode 1
Select number
Prescale 1,000
Decimal point No
0 1 2 3 4 5 6 7 8 9
Reset key Enabled
B-45
KCN-S/KCN-W Counter Functions
Electronic
Counters
Press the MODE key and the key at the same time for at least
0.5 second.
Press the MODE key and the key at the same time for at least
KCV
0.5 second, or leave the system in the Setup mode for one minute.
MODE
Select new value
0 1 2 3 4 5 6 7 8 9 (-) Select number
KCN-S/W
*
Initializing the counter Prescale Select digit 0 1. 0 0 0
In the Setup mode, the counter can be initialized using the menu as scale
KCN-B
.n .n .n .n .n .n
Input logic Select input logic
KCX-RN
signl
* Reset key Select reset key mode
MODE p o s n e g
positive
(voltage input))
negative
(no voltage input)
reset
MODE *
e n a b d i s a
Setmode Select set mode between single and enable disable
reset key reset key
dual preset
KCH-B
prset
*
MODE 2 1
(dual preset) (single preset) Notes:
1. After you change a current setting, always press the ENT key
Output mode Select output mode to store the new value.
c-op 2. indicates a value set at delivery.
KCM
*
MODE 1 2 3 4 7 8 3. After you change an initial setting, always press the RST key
to reset the count.
Selecting Mode 7 or 8 changes the
operation mode to Addition. 4. The displayed count is determined by the prescale and the
decimal point location. For example, if the prescale is set to
1.200 and the decimal point is set as nnn.nHn, each pulse input
increments the count as follows:
0.012 0.024 0.036 0.048 0.060...
B-46
Counter Functions KCN-S/KCN-W
Electronic
Counters
3. KCN-W Multifunction Dual Preset Mode
Switching between Setup mode and Run mode
Press the MODE key and the key at the same time for at least
0.5 second.
Press the MODE key and the key at the same time for at least
0.5 second, or leave the system in the Setup mode for one minute.
KCN-A
Changing a preset value
Select Dual preset in the Setup mode, then switch to the Run mode to change the OUT2 Output duration Select digit 1 0 0 ms *
value as follows: Output duration can
out-t be set or changed The lowest digit fixed
only in Output at "0", and cannot be
Switch preset Mode 2,3, or 6.
KCN-A
MODE value display
SET2 SET1 changed.
MODE Setting at "0" cannot
be made.
KCN-S/W
only in Output
Mode 5 or 6. 0 1 2 3 4 5 6 7 8 9
MODE
Select new value
0 1 2 3 4 5 6 7 8 9 (-) *
Prescale Select digit 0 1. 0 0 0
The minus sigh (-) can be scale
KCN-B
selected only for the highest digit.
ENT Store new value
Setting at "0" cannot
be made.
KCN-T
Counting speed Select counting speed
0 1 2 3 4 5 6 7 8 9
speed
*
MODE 5 0 0 0 2 0 0 0 1 0 0 0 3 0
[Hz]
KCY
point
H denotes the ones'
in digit before the
* h h h h h h decimal point is set.
MODE q u a d a .
d s .
b
(two-phase) (addition or subtraction)
KCX
count Select decimal point position
*
MODE c l e r r e t n
(power-on reset) (memory backup)
.n .n .n .n .n .n
Operation mode Select operation mode KCX-RN
c-dtr The operation mode
* can be changed in Reset key Select reset key mode
MODE u p d n the Output Modes
(addition) (subtraction) 1 to 4. reset
MODE *
e n a b d i s a
Input logic Select input logic enable disable
reset key reset key
signl
KCH-B
*
MODE p o s n e g Notes:
positive negative
(voltage input) (no voltage input) 1. After you change a current setting, always press the ENT key
Set mode Select set mode between single and to store the new value.
dual preset 2. indicates a value set at delivery.
prset 3. After you change an initial setting, always press the RST key
*
KCM
B-47
KCN-S/KCN-W Timer Functions
Electronic
Counters
Timer option
KCN-4S Series General Purpose 4-digit Counters can be used also as high-precision timers.
To use the timer option, connect the pins 5 and 6 before turning the power on.
Output mode diagrams 100,000 writes. Avoid turning the power off more than necessary.
0 0
Start Start
Reset
KCX
Reset
OUT OUT
SET SET2
SET1
0
Start 0
KCH-B
Start
Reset
Reset
OUT
OUT
Mode E Accumulation
KCM
B-48
Timer Functions KCN-S/KCN-W
Electronic
Counters
Wiring Diagrams
KCN-4SR KCN-4ST
Sensor power Sensor power Sensor power Sensor power
DC24V 0V C/T DC24V 0V C/T
15mA Start 15mA Start
KCN-A
AC AC AC AC
100V 200V 100V 200V
KCN-A
OUT OUT 0V
Relay output DC output Common output
KCN-4SR-C KCN-4ST-C
Common input Common input
0V C/T 0V C/T
KCN-S/W
Start Start
KCN-B
OUT OUT 0V
Relay output DC power DC24V DC output Common output DC power DC24V
KCN-T
Dimensions of To use the timer option, connect the 0V pin and the
C/T pin before turning the power on.
6.3
Terminal Block
8.5
10.55
KCY
7.62 M3 screw
KCX
For relay For relay
Sensor Internal power output DC24V output
power 2 source 24V
2 Internal circuit
source
DC24V ON for nagative input 10 ON for negative input 10 KCX-RN
OUT OUT
11 13 11
5V 5V
KCH-B
3.3k 3.3k
Start
Start 3 3
15k 15k
10 OUT 10 OUT
5V 5V
KCM
3.3k 3.3k
Reset 7 Reset 7
15k 15k
0V 5 11 0V 0V 5 11 0V
B-49
KCN-S/KCN-W Timer Functions
Electronic
Counters
Input logic: Positive (voltage) input(pos) Input logic: Negative (no voltage) input (neg)
(White) (White)
7 Reset signal input 7 Reset signal input
Black Black
(White) (White)
KCN-S/W
5 0V 5 0V
Input logic: Negative (no voltage) input (neg) Input logic: Positive (voltage) input (pos) Input logic: Negative (no voltage) input (neg)
KCN-T
5 0V 5 0V 5 0V
KCX-RN
MAX.100mA
OUT
0V 11 11
Load power rated at 24 V
B-50
Timer Functions KCN-S/KCN-W
Electronic
Counters
Front Panel Layout and Description
Front panel
Count (zero-suppressed)
Character height: 13 mm
Initial settings are displayed in the Setup mode.
Preset value
Initial settings are displayed
KCN-A
in the Setup mode.
Measurement unit
H:M: hours: minutes
M:S: minutes: seconds
KCN-A
S: seconds
Output status
Flicker mode: 1- or 2-step
Reset key
Resets initial settings in the
KCN-S/W
MODE
Setup mode.
Response time: 0.5 second RST ENT ENTER key:
Used to store settings.
MODE key:
Used to change display mode or operation
KCN-B
mode. Press this key and the key at the key:
same time to change operation mode Right arrow key: Used to select a digit or set
between Run and Setup. Press this key to shift one digit to the right. its value.
KCN-T
Operating procedures
Switching between Setup mode and Run mode Initializing the timer
KCY
Press the MODE key and the key at the same time for at least *
MODE u p d n
addition subtraction
0.5 second.
Press the MODE key and the key at the same time for at least
Input logic Select input logic
0.5 second, or leave the system in the Setup mode for one minute.
signl
*
KCX
MODE p o s n e g
negative
Changing a preset value positive
power input power input
Notes:
1. After you change a current setting, always press the ENT key
to store the new value.
2. indicates a value set at delivery.
3. After you change an initial setting, always press the RST key
to reset the count.
B-51
KCN-S/KCN-W Counter/Timer Functions
Electronic
Counters
p s e t 2 SET2 error.
s p e e d Counting speed memory data error
c - o p Output mode memory data error
o u t - t 1 Output duration memory data error
KCN-A
e r r o u t - t 1 2 OUT1 output duration memory data error A memory data error occurs when the current settings do
o u t - t 2 2 OUT2 output duration memory data error not produce a meaningful result.
Counter The KCN-W counters integrate a switching source circuit. Starting the counter
Set value causes a surge current to flow into the circuit and may prevent counter operation.
Item
KCN-S KCN-W Use a power source with a sufficient capacity to prevent the surge current.
First setting 1000 Keep the source voltage in the 20 to 30 V range for DC 2-wire proximity switch.
After changing initial settings, always press the RST key to reset the counter.
KCX
Prescale 1.000 During counting, any change to a preset value become. Avoid using the counter
Decimal point nnnnnh. in the environments where:
Reset key Enabled (1)Ambient temperature is above 50 or below 10 .
Timer (2)Ambient humidity exceeds 85 , or abrupt temperature changes may cause
dewing.
Item Set value
KCM
(3)The operation may be affected by dust, metal chips, corrosive gases or other
First setting 10.00
harmful objects.
Second setting 50.00
(4)The machine is exposed to direct sunlight.
Operation Addition
(5)You anticipate vibration or shock.
Input logic Negative
Keep the following in mind when wiring:
Timer mode Mode A
(1)The wiring to the counter should be separated from power line.
Timer range n n. n n (s)
(2)Keep the counter body and wiring away from noise sources.
Reset key Enabled
(3)Never use a free terminal as a relay.
Isolate the counter from the control circuit before testing insulation voltage and
resistance.
B-52
KCN-S/KCN-W
Electronic
Counters
External Dimensions (in mm)
KCN-A
48
44.5
KCN-A
Protective cover 1 to 5 mm thick panel Depth
KCN-S/W
48 45 10 DC power 61mm
(50.4) 6 55 (for DC power) AC power 96mm
63
KCN-B
Boring dimensions for Installation
1. Horizontally aligned handles 2. Vertically aligned handles
Mounting
70 or more 55 or more 48 mm for tight alignment without
bracket
KCN-T
the protective cover
Square
45 +0.3
hole
0
aligned tight.
May be
48 +0.2
KCY
0
70 or more
45 +0.3
0
Protective cover
KCX
KCX-RN
KCH-B
KCM
B-53