0% found this document useful (0 votes)
6 views14 pages

chọn đènn

The document provides detailed lighting specifications for various rooms in Building 1, including ground area, clearance height, reflection factors, and maintenance factors. It includes calculated results for working plane illuminance, lighting power density, energy consumption, and glare valuation for each room. A luminaire list with specifications for each lighting fixture used is also included.

Uploaded by

vutrongdac1807
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
6 views14 pages

chọn đènn

The document provides detailed lighting specifications for various rooms in Building 1, including ground area, clearance height, reflection factors, and maintenance factors. It includes calculated results for working plane illuminance, lighting power density, energy consumption, and glare valuation for each room. A luminaire list with specifications for each lighting fixture used is also included.

Uploaded by

vutrongdac1807
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 14

Project

Building 1 · tầng 1 · phòng khách (Light scene 1)


Summary

Ground area 23.82 m² Clearance height 3.700 m

Reflection factors Ceiling: 70.0 %, Mounting height 3.730 m


Walls: 50.0 %,
Floor: 20.0 % Height Working plane 0.800 m

Maintenance factor 0.80 (fixed) Wall zone Working plane 0.500 m

1
Project

Building 1 · tầng 1 · phòng khách (Light scene 1)


Summary

Results

Symbol Calculated Target Check Index

Working plane Ēperpendicular 180 lx ≥ 200 lx WP3

Uo (g1 ) 0.67 ≥ 0.10 WP3

Lighting power density 6.56 W/m² –

3.64 W/m²/100 lx –

Glare valuation(1) RUG, max 19 ≤ 19

Energy estimation(2) Consumption 11.9 kWh/a max. 850 kWh/a

Space Lighting power density 3.69 W/m² –

2.05 W/m²/100 lx –

(1) Based on a rectangular space of 5.400 m x 6.000 m and SHR of 0.25.


(2) Calculated using DIN:18599-4.

Utilisation profile: Offices (5.26.1 Filing, copying, etc.)

Luminaire list

pcs. Manufacturer Article No. Article name RUG P Φ Luminous efficacy

2 Rang Dong LN29N 300x300/24W 19 24.0 W 2002 lm 83.4 lm/W

1 Rang Dong LN16 LN16 540x540/40W – 40.0 W 4000 lm 100.0 lm/W


540x540/4
0W

2
Project

Building 1 · tầng 1 · phòng ngủ 1 (Light scene 1)


Summary

Ground area 10.56 m² Clearance height 3.700 m

Reflection factors Ceiling: 70.0 %, Mounting height 3.700 m


Walls: 50.0 %,
Floor: 20.0 % Height Working plane 0.800 m

Maintenance factor 0.80 (fixed) Wall zone Working plane 0.500 m

3
Project

Building 1 · tầng 1 · phòng ngủ 1 (Light scene 1)


Summary

Results

Symbol Calculated Target Check Index

Working plane Ēperpendicular 121 lx ≥ 100 lx WP1

Uo (g1 ) 0.76 ≥ 0.10 WP1

Lighting power density 7.91 W/m² –

6.56 W/m²/100 lx –

Energy estimation(2) Consumption 5.40 kWh/a max. 400 kWh/a

Space Lighting power density 3.79 W/m² –

3.14 W/m²/100 lx –

(1) Based on a rectangular space of 3.300 m x 3.200 m and SHR of 0.25.


(2) Calculated using DIN:18599-4.

Utilisation profile: Offices (5.26.1 Filing, copying, etc.)

Luminaire list

pcs. Manufacturer Article No. Article name RUG P Φ Luminous efficacy

1 Rang Dong LDL 012 LN28 DM 400/40W – 40.0 W 2800 lm 70.0 lm/W

4
Project

Building 1 · tầng 1 · wc 1 (Light scene 1)


Summary

Ground area 3.36 m² Clearance height 2.500 m

Reflection factors Ceiling: 70.0 %, Mounting height 2.500 m


Walls: 50.0 %,
Floor: 20.0 % Height Working plane 0.800 m

Maintenance factor 0.80 (fixed) Wall zone Working plane 0.500 m

5
Project

Building 1 · tầng 1 · wc 1 (Light scene 1)


Summary

Results

Symbol Calculated Target Check Index

Working plane Ēperpendicular 200 lx ≥ 100 lx WP2

Uo (g1 ) 0.88 ≥ 0.10 WP2

Lighting power density 27.27 W/m² –

13.66 W/m²/100 lx –

Energy estimation(2) Consumption 2.43 kWh/a max. 150 kWh/a

Space Lighting power density 5.36 W/m² –

2.68 W/m²/100 lx –

(1) Based on a rectangular space of 2.100 m x 1.600 m and SHR of 0.25.


(2) Calculated using DIN:18599-4.

Utilisation profile: Offices (5.26.1 Filing, copying, etc.)

Luminaire list

pcs. Manufacturer Article No. Article name RUG P Φ Luminous efficacy

1 Rang Dong LN29N 220/18W – 18.0 W 1450 lm 80.5 lm/W

6
Project

Building 1 · tầng 2 · phòng ngủ 2 (Light scene 1)


Summary

Ground area 10.23 m² Clearance height 3.700 m

Reflection factors Ceiling: 70.0 %, Mounting height 3.700 m


Walls: 50.0 %,
Floor: 20.0 % Height Working plane 0.800 m

Maintenance factor 0.80 (fixed) Wall zone Working plane 0.465 m

7
Project

Building 1 · tầng 2 · phòng ngủ 2 (Light scene 1)


Summary

Results

Symbol Calculated Target Check Index

Working plane Ēperpendicular 121 lx ≥ 100 lx WP4

Uo (g1 ) 0.77 ≥ 0.10 WP4

Lighting power density 7.78 W/m² –

6.42 W/m²/100 lx –

Energy estimation(2) Consumption 5.40 kWh/a max. 400 kWh/a

Space Lighting power density 3.91 W/m² –

3.23 W/m²/100 lx –

(1) Based on a rectangular space of 3.300 m x 3.099 m and SHR of 0.25.


(2) Calculated using DIN:18599-4.

Utilisation profile: Offices (5.26.1 Filing, copying, etc.)

Luminaire list

pcs. Manufacturer Article No. Article name RUG P Φ Luminous efficacy

1 Rang Dong LDL 012 LN28 DM 400/40W – 40.0 W 2800 lm 70.0 lm/W

8
Project

Building 1 · tầng 2 · phòng ngủ 3 (Light scene 1)


Summary

Ground area 13.49 m² Clearance height 3.700 m

Reflection factors Ceiling: 70.0 %, Mounting height 3.700 m


Walls: 50.0 %,
Floor: 20.0 % Height Working plane 0.800 m

Maintenance factor 0.80 (fixed) Wall zone Working plane 0.500 m

9
Project

Building 1 · tầng 2 · phòng ngủ 3 (Light scene 1)


Summary

Results

Symbol Calculated Target Check Index

Working plane Ēperpendicular 107 lx ≥ 100 lx WP7

Uo (g1 ) 0.71 ≥ 0.10 WP7

Lighting power density 5.69 W/m² –

5.33 W/m²/100 lx –

Energy estimation(2) Consumption 5.40 kWh/a max. 500 kWh/a

Space Lighting power density 2.97 W/m² –

2.78 W/m²/100 lx –

(1) Based on a rectangular space of 4.350 m x 3.100 m and SHR of 0.25.


(2) Calculated using DIN:18599-4.

Utilisation profile: Offices (5.26.1 Filing, copying, etc.)

Luminaire list

pcs. Manufacturer Article No. Article name RUG P Φ Luminous efficacy

1 Rang Dong LDL 012 LN28 DM 400/40W – 40.0 W 2800 lm 70.0 lm/W

10
Project

Building 1 · tầng 2 · sảnh tầng 1 (Light scene 1)


Summary

Ground area 13.74 m² Clearance height 3.700 m

Reflection factors Ceiling: 70.0 %, Mounting height 3.700 m


Walls: 50.0 %,
Floor: 20.0 % Height Working plane 0.800 m

Maintenance factor 0.80 (fixed) Wall zone Working plane 0.500 m

11
Project

Building 1 · tầng 2 · sảnh tầng 1 (Light scene 1)


Summary

Results

Symbol Calculated Target Check Index

Working plane Ēperpendicular 121 lx ≥ 100 lx WP6

Uo (g1 ) 0.81 ≥ 0.10 WP6

Lighting power density 7.51 W/m² –

6.19 W/m²/100 lx –

Energy estimation(2) Consumption 6.48 kWh/a max. 500 kWh/a

Space Lighting power density 3.49 W/m² –

2.88 W/m²/100 lx –

(1) Based on a rectangular space of 2.252 m x 6.100 m and SHR of 0.25.


(2) Calculated using DIN:18599-4.

Utilisation profile: Offices (5.26.1 Filing, copying, etc.)

Luminaire list

pcs. Manufacturer Article No. Article name RUG P Φ Luminous efficacy

2 Rang Dong LDL 012 LN29N 300/24W – 24.0 W 2000 lm 83.3 lm/W

12
Project

Building 1 · tầng 2 · wc 2 (Light scene 1)


Summary

Ground area 3.62 m² Clearance height 2.500 m

Reflection factors Ceiling: 70.0 %, Mounting height 2.500 m


Walls: 50.0 %,
Floor: 20.0 % Height Working plane 0.800 m

Maintenance factor 0.80 (fixed) Wall zone Working plane 0.500 m

13
Project

Building 1 · tầng 2 · wc 2 (Light scene 1)


Summary

Results

Symbol Calculated Target Check Index

Working plane Ēperpendicular 172 lx ≥ 100 lx WP5

Uo (g1 ) 0.88 ≥ 0.10 WP5

Lighting power density 23.79 W/m² –

13.81 W/m²/100 lx –

Energy estimation(2) Consumption 2.43 kWh/a max. 150 kWh/a

Space Lighting power density 4.98 W/m² –

2.89 W/m²/100 lx –

(1) Based on a rectangular space of 1.603 m x 2.258 m and SHR of 0.25.


(2) Calculated using DIN:18599-4.

Utilisation profile: Offices (5.26.1 Filing, copying, etc.)

Luminaire list

pcs. Manufacturer Article No. Article name RUG P Φ Luminous efficacy

1 Rang Dong LN29N 220/18W – 18.0 W 1450 lm 80.5 lm/W