Building 1 · tầng 1 · phòng khách (Light scene 1)
Summary
Ground area 23.82 m² Clearance height 3.700 m
Reflection factors Ceiling: 70.0 %, Mounting height 3.730 m
Walls: 50.0 %,
Floor: 20.0 % Height Working plane 0.800 m
Maintenance factor 0.80 (fixed) Wall zone Working plane 0.500 m
1
Project
Building 1 · tầng 1 · phòng khách (Light scene 1)
Summary
Results
Symbol Calculated Target Check Index
Working plane Ēperpendicular 180 lx ≥ 200 lx WP3
Uo (g1 ) 0.67 ≥ 0.10 WP3
Lighting power density 6.56 W/m² –
3.64 W/m²/100 lx –
Glare valuation(1) RUG, max 19 ≤ 19
Energy estimation(2) Consumption 11.9 kWh/a max. 850 kWh/a
Space Lighting power density 3.69 W/m² –
2.05 W/m²/100 lx –
(1) Based on a rectangular space of 5.400 m x 6.000 m and SHR of 0.25.
(2) Calculated using DIN:18599-4.
Utilisation profile: Offices (5.26.1 Filing, copying, etc.)
Luminaire list
pcs. Manufacturer Article No. Article name RUG P Φ Luminous efficacy
2 Rang Dong LN29N 300x300/24W 19 24.0 W 2002 lm 83.4 lm/W
1 Rang Dong LN16 LN16 540x540/40W – 40.0 W 4000 lm 100.0 lm/W
540x540/4
0W
2
Project
Building 1 · tầng 1 · phòng ngủ 1 (Light scene 1)
Summary
Ground area 10.56 m² Clearance height 3.700 m
Reflection factors Ceiling: 70.0 %, Mounting height 3.700 m
Walls: 50.0 %,
Floor: 20.0 % Height Working plane 0.800 m
Maintenance factor 0.80 (fixed) Wall zone Working plane 0.500 m
3
Project
Building 1 · tầng 1 · phòng ngủ 1 (Light scene 1)
Summary
Results
Symbol Calculated Target Check Index
Working plane Ēperpendicular 121 lx ≥ 100 lx WP1
Uo (g1 ) 0.76 ≥ 0.10 WP1
Lighting power density 7.91 W/m² –
6.56 W/m²/100 lx –
Energy estimation(2) Consumption 5.40 kWh/a max. 400 kWh/a
Space Lighting power density 3.79 W/m² –
3.14 W/m²/100 lx –
(1) Based on a rectangular space of 3.300 m x 3.200 m and SHR of 0.25.
(2) Calculated using DIN:18599-4.
Utilisation profile: Offices (5.26.1 Filing, copying, etc.)
Luminaire list
pcs. Manufacturer Article No. Article name RUG P Φ Luminous efficacy
1 Rang Dong LDL 012 LN28 DM 400/40W – 40.0 W 2800 lm 70.0 lm/W
4
Project
Building 1 · tầng 1 · wc 1 (Light scene 1)
Summary
Ground area 3.36 m² Clearance height 2.500 m
Reflection factors Ceiling: 70.0 %, Mounting height 2.500 m
Walls: 50.0 %,
Floor: 20.0 % Height Working plane 0.800 m
Maintenance factor 0.80 (fixed) Wall zone Working plane 0.500 m
5
Project
Building 1 · tầng 1 · wc 1 (Light scene 1)
Summary
Results
Symbol Calculated Target Check Index
Working plane Ēperpendicular 200 lx ≥ 100 lx WP2
Uo (g1 ) 0.88 ≥ 0.10 WP2
Lighting power density 27.27 W/m² –
13.66 W/m²/100 lx –
Energy estimation(2) Consumption 2.43 kWh/a max. 150 kWh/a
Space Lighting power density 5.36 W/m² –
2.68 W/m²/100 lx –
(1) Based on a rectangular space of 2.100 m x 1.600 m and SHR of 0.25.
(2) Calculated using DIN:18599-4.
Utilisation profile: Offices (5.26.1 Filing, copying, etc.)
Luminaire list
pcs. Manufacturer Article No. Article name RUG P Φ Luminous efficacy
1 Rang Dong LN29N 220/18W – 18.0 W 1450 lm 80.5 lm/W
6
Project
Building 1 · tầng 2 · phòng ngủ 2 (Light scene 1)
Summary
Ground area 10.23 m² Clearance height 3.700 m
Reflection factors Ceiling: 70.0 %, Mounting height 3.700 m
Walls: 50.0 %,
Floor: 20.0 % Height Working plane 0.800 m
Maintenance factor 0.80 (fixed) Wall zone Working plane 0.465 m
7
Project
Building 1 · tầng 2 · phòng ngủ 2 (Light scene 1)
Summary
Results
Symbol Calculated Target Check Index
Working plane Ēperpendicular 121 lx ≥ 100 lx WP4
Uo (g1 ) 0.77 ≥ 0.10 WP4
Lighting power density 7.78 W/m² –
6.42 W/m²/100 lx –
Energy estimation(2) Consumption 5.40 kWh/a max. 400 kWh/a
Space Lighting power density 3.91 W/m² –
3.23 W/m²/100 lx –
(1) Based on a rectangular space of 3.300 m x 3.099 m and SHR of 0.25.
(2) Calculated using DIN:18599-4.
Utilisation profile: Offices (5.26.1 Filing, copying, etc.)
Luminaire list
pcs. Manufacturer Article No. Article name RUG P Φ Luminous efficacy
1 Rang Dong LDL 012 LN28 DM 400/40W – 40.0 W 2800 lm 70.0 lm/W
8
Project
Building 1 · tầng 2 · phòng ngủ 3 (Light scene 1)
Summary
Ground area 13.49 m² Clearance height 3.700 m
Reflection factors Ceiling: 70.0 %, Mounting height 3.700 m
Walls: 50.0 %,
Floor: 20.0 % Height Working plane 0.800 m
Maintenance factor 0.80 (fixed) Wall zone Working plane 0.500 m
9
Project
Building 1 · tầng 2 · phòng ngủ 3 (Light scene 1)
Summary
Results
Symbol Calculated Target Check Index
Working plane Ēperpendicular 107 lx ≥ 100 lx WP7
Uo (g1 ) 0.71 ≥ 0.10 WP7
Lighting power density 5.69 W/m² –
5.33 W/m²/100 lx –
Energy estimation(2) Consumption 5.40 kWh/a max. 500 kWh/a
Space Lighting power density 2.97 W/m² –
2.78 W/m²/100 lx –
(1) Based on a rectangular space of 4.350 m x 3.100 m and SHR of 0.25.
(2) Calculated using DIN:18599-4.
Utilisation profile: Offices (5.26.1 Filing, copying, etc.)
Luminaire list
pcs. Manufacturer Article No. Article name RUG P Φ Luminous efficacy
1 Rang Dong LDL 012 LN28 DM 400/40W – 40.0 W 2800 lm 70.0 lm/W
10
Project
Building 1 · tầng 2 · sảnh tầng 1 (Light scene 1)
Summary
Ground area 13.74 m² Clearance height 3.700 m
Reflection factors Ceiling: 70.0 %, Mounting height 3.700 m
Walls: 50.0 %,
Floor: 20.0 % Height Working plane 0.800 m
Maintenance factor 0.80 (fixed) Wall zone Working plane 0.500 m
11
Project
Building 1 · tầng 2 · sảnh tầng 1 (Light scene 1)
Summary
Results
Symbol Calculated Target Check Index
Working plane Ēperpendicular 121 lx ≥ 100 lx WP6
Uo (g1 ) 0.81 ≥ 0.10 WP6
Lighting power density 7.51 W/m² –
6.19 W/m²/100 lx –
Energy estimation(2) Consumption 6.48 kWh/a max. 500 kWh/a
Space Lighting power density 3.49 W/m² –
2.88 W/m²/100 lx –
(1) Based on a rectangular space of 2.252 m x 6.100 m and SHR of 0.25.
(2) Calculated using DIN:18599-4.
Utilisation profile: Offices (5.26.1 Filing, copying, etc.)
Luminaire list
pcs. Manufacturer Article No. Article name RUG P Φ Luminous efficacy
2 Rang Dong LDL 012 LN29N 300/24W – 24.0 W 2000 lm 83.3 lm/W
12
Project
Building 1 · tầng 2 · wc 2 (Light scene 1)
Summary
Ground area 3.62 m² Clearance height 2.500 m
Reflection factors Ceiling: 70.0 %, Mounting height 2.500 m
Walls: 50.0 %,
Floor: 20.0 % Height Working plane 0.800 m
Maintenance factor 0.80 (fixed) Wall zone Working plane 0.500 m
13
Project
Building 1 · tầng 2 · wc 2 (Light scene 1)
Summary
Results
Symbol Calculated Target Check Index
Working plane Ēperpendicular 172 lx ≥ 100 lx WP5
Uo (g1 ) 0.88 ≥ 0.10 WP5
Lighting power density 23.79 W/m² –
13.81 W/m²/100 lx –
Energy estimation(2) Consumption 2.43 kWh/a max. 150 kWh/a
Space Lighting power density 4.98 W/m² –
2.89 W/m²/100 lx –
(1) Based on a rectangular space of 1.603 m x 2.258 m and SHR of 0.25.
(2) Calculated using DIN:18599-4.
Utilisation profile: Offices (5.26.1 Filing, copying, etc.)
Luminaire list
pcs. Manufacturer Article No. Article name RUG P Φ Luminous efficacy
1 Rang Dong LN29N 220/18W – 18.0 W 1450 lm 80.5 lm/W
14