STEEL

STIFFENED
DOOR
NAFFCO ‘Falcon’ Steel Stiffened Door’s highly robust
construction, above average impact resistance, optimal
thermal insulation and sound attenuation characteristics
make them ideal for openings where rough usage and
high traffic are considerations such as – Schools,
healthcare, offices, commercial establishments, public
sector construction and manufacturing buildings.

Key Features
 Fabricated and Assembled in UAE
 Highly Economical and Environmental Friendly
 Cold Rolled Steel, Metallic Coated as per ASTM A 792 Standard offering Superior corrosion
resistance
 20GA Vertical Stiffeners placed at ideal intervals offering exceptional rigidity and stiffness
 Rockwool Insulation between adjacent Stiffeners to limit Thermal and Sound Transmission
 Temperature Rise Rating up to 450°F @ 30 minutes on unexposed face of the Door
 Up to 180* Minutes Fire Integrity
 Tested to UBC 7-2, ANSI/UL 10B, 10C (Positive Pressure Test Standard) or BS 476 Part 22 Standard
 Sound Transmission Class: STC 38 (Operable)
 Thermal Characteristics: U Factor – 0.7, R Factor – 1.42
 Mechanically interlocked vertical edge seam construction for added structural strength
 1-3/4” thick Door Leaf suited for wider selection of builders hardware
 Suited for light, medium, heavy duty and extra-heavy duty usage
 16GA Inverted end channels welded to both face sheets
 Factory Powder Coated
 8GA Galvanized Steel Hinge Reinforcement and 13GA Galvanized Steel Closer Reinforcement

www.naf fco.co m
Available Options
 Base Material Options – Hot Dip Metallic Coated Cold Rolled Steel as per ASTM A 792 Standards
 2-1/8” Door Leaf Thickness
 Finish Options – Smooth Power Coated. Wood Finish (or) Hard Textured Finish.
 Design Options – Full Flush (or) Vision Lite (or) Bottom Louver
 Synthetically filled Seamless Edges
 Flush Metal Caps for End Channel
 Multiple Frame Profile Options
 Beveled Edge – 1/8” in 2”
 Selection of Thickness from Light to Extra Heavy Duty (Refer the below table)
 Cladded (Glass, Brass, Stainless Steel)

Areas of Applications
 Office  Industry
 Power-Plant  Oil Field
 Recording Studio  Stadium
 Motel / Hotel  Healthcare
 Institution  Public Utility
 Factory  Warehouse

Door Performance Level Chart


Physical Endurance
Model Type Gauge Metric(mm)
(Cycle Testing)
LEVEL 1 – LIGHT COMMERCIAL DUTY
1 FULL FLUSH 18 1.2 1,000,000 Cycles
2 SEAMLESS 18 1.2 1,000,000 Cycles
LEVEL 2 – HEAVY COMMERCIAL DUTY
1 FULL FLUSH 16 1.5 1,000,000 Cycles
2 SEAMLESS 16 1.5 1,000,000 Cycles
LEVEL 3 – EXTRA HEAVY COMMERCIAL DUTY
1 FULL FLUSH 14 2.0 1,000,000 Cycles
2 SEAMLESS 14 2.0 1,000,000 Cycles

Indicative Size Selection Chart


(All sizes in meters – width x Height basis)

Width
Height
Single Double

0.8 1.6 2.0 2.2 2.4

0.9 1.8 2.0 2.2 2.4

1.0 2.0 2.0 2.2 2.4

1.1 2.1 2.0 2.2 2.4

1.22 2.2 2.0 2.2 2.4

www.naf fco.co m
Design Options

Flush Full Glass Half Glass Two Glass Full Louver

Double Louver Bottom Narrow Vision Narrow Vision Vision Vision with
Louver with Bottom Bottom
Louver Louver