Model:300WQC700-17-55

Name: Submersible
Sewage Pump

2025.7.31
Project Name Алена

Personal Name Aquastrong Company Name


Company Address

Product Model 300WQC700-17-55

Product Recommendations
Flow(m³/h) 700 Head(m) 17 Power(kW) 55

Based on provided information and product parameters, recommends model


300WQC700-17-55

Introduction
Application
Wastewater drainage in factories, construction sites and commercial facities;
Drainage system in municipal sewage treatment plants;
Drainage station in residential quarters;
Municipal projects;
Methane pools and field irrigation in countryside.

Pump
Max.immersion depth:10m(0.75-5.5kW-2P)20m(7.5kW-2P/5.5-45kW-4P);
Cable Length:10m (under 30kW),8m (30~45kW);
Max. liquid temperature: up to +40℃;
Liquid PH value: 6 -10;
Max.liquid density: 1.3x10³kg/m³;
Allowed by the particle diameter: 20 - 80mm;
Float switch: single phase.

Motor
Copper winding
Insulation class:F;
Protection class:IP68;
Motor protection: 0.25 - 4kW(5.5kW and above need control cabinet);
Start method: Below 45kW is direct start, 45kW is star-delta start.

Product Parameters
Nameplate

Pump flow rate(m³/h) 700 Total manometric head H(m) 17


Overall efficiency(%) 80 Speed(rpm) 980

Technical

Motor power(kW) 55 Maximum use flow(m³/h) 840

1/5
Material

Impeller ZG07Cr19Ni10 Pump body HT250


Seal ring 06Cr19Ni10 Guide 06Cr19Ni10
Hanging chain 06Cr19Ni10 Motor casing HT250
Mechanical seal UpperCeramic/Carbon,LowerSic/Carbon

Working conditions

Medium temperature high(℃) ≤42℃ Max. Particles Size(mm) 100


Max. liquid density(Kg/m³) 1.2X10³Kg/m³ Max. immersion depth(m) 20
Pumped medium It can pump sewage containing long fibers, plastic bags, cloth gloves, etc.

Installation

Outlet diameter(mm) 300 Pipe Diameter(mm) 300


Installation form Standard coupling type
Optional accessories Export matching flange

Motor

Motor phase Three phase Protection class IP68


Insulation class H Motor power(kW) 55
Frequency(Hz) 50 Rated voltage(V) 380
Rated current(A) 103.2 Power factor 0.87
Outer diameter of stator(mm) 400

Weight/Packaging

Pump weight(kg) 1335

Other

The protection function is optional

Area Range Parameters

Max Q(m³/h) 840.0 Allowable Minimum (m³/h) 210.0


Allowable Maximum (m³/h) 1008.0 Min Value Optimal area (m³/h) 588.0
Max Value Optimal area (m³/h) 1008.0

2/5
Performance Curve

Basic Parameters
Pump flow Total Overall Pump power
rate(m³/h) manometric efficiency(%) input(kW)
head H(m)

Rated Point 700.00 17.00 80

Work Point 630.00 18.80 78.62 41.12

Minimum Allowed Point 210.00 23.88 42.60 32.52

Maximum Allowed Point 1008.00 8.88 70.98 37.60

Optimal Working Area (Small) 588.00 19.72 77.51 40.82

Optimal Working Area (Large) 1008.00 8.88 70.98 37.60

3/5
Shape & Size

4/5
Exploded View

WQ 5/5