MULTYFRY
FH1394 / 1 - FH1394 / 2
Technical Sheet DSDL_16019_A
Characteristics
Automatic mixing paddle
The motion of the paddle gently mixes food and permits cooking without any need to manually stir food.
Upper
heating element + fan
The combination of the 1400 W heating element and fan provides a centralized uniform distribution of
heated air that allows you to cook with convection and grill resulting in better and more rapid frying
performances.
Double
heating element + fan
The second heating element is a unique feature in low-oil fryers. Positioned under the bowl, it speeds
up the cooking process and improves the quality of cooking for a greater selection of recipes.
Technical Sheet DSDL_16019_A
Description the appliance
A Lid
B Hot air discharge grille (ventilation)
C Viewing window release buttons
D Removable viewing window
E Maximum level MAX
F Power cord
G Condensate tray
H Main ON/OFF button
I Paddle
J Ceramic coated bowl
K Handle slide
L Bowl handgrip
M Oil measure (level from 1 to 5)
N Luminous power level bar
O Power level button
P Timer button + (increases time)
Q Display
R Timer button - (decreases time)
S Cooking programme selector dial
T Luminous programme start/stop button
U Appliance body
V Handle for lifting the appliance
W Lid open button
X Condensate channel
Technical Sheet DSDL_16019_A
Technical Data
Voltage-Frequency V~Hz 220/240~50/60
Power upper heating element W 1400
Power lower heating element W 1000
Technical Sheet DSDL_16019_A
Troubleshooting
ERROR 1 : The temperature slope (variation of temperature) measured on NTC (FAN) or NTC (bottom) are greater than
MAXIMUN admitted, all the loads are stopped,the alarm E1 will be shown in the display and the buzer will emits 3 short BIP
ERROR 3 : The temperature overcome the SAFETY and the alarm E3 will be shown in the display and the Buzzer
will emits 5 short BIP. All the load are stopped. The error is works as follow :
RECIPE ERROR when pass: ERROR ON :
NTC (Fan) safety temp NTC ( Bottom) safety temp
1 N/A YES
2 YES NO
3 YES NO
4 YES NO
5 YES NO
6 YES NO
7 N/A YES
ERROR 5 : If the system cannot read correctly the temperature from Fan NTC (if resistance is lower than 0.1 kOhm or
higher than 640 kOhm) : alarm E5 will be shown in the display and the buzer will emits 7 short Bip. All the loads are stopped.
ERROR 6 : If the system cannot read correctly the temperature from Bottom NTC (if resistance is lower than 0.1 kOhm or
higher than 640 kOhm) : alarm E6 will be shown in the display and the buzer will emits 7 short Bip.
All the loads are stopped.
NOTE : All the acoustic alarms will be repeat cyclically with a pause of 1 minute up to an user (pressure of start key ).
The display will show the error up to machine switch off.
Technical Sheet DSDL_16019_A
Electrical diagram
Legend
SW1 Main switch
HET Top Heater
HEB Vessel Heater
MT Top motor
MB Stirrer motor
TCOB Thermal cut-off bottom
TCOT Thermal cut-off top
MS1 Lid microswitch
MSV Vessel microswitch
PCB2 PCB display
PCB3 PCB pawer
AF Fan
Technical Sheet DSDL_16019_A
Self diagnostic
1 ) Press the power button, the key level, the + button,
then it will be displayed the software version
2 ) Press the level max button to control the LEDs, and
the function knob
3 ) Press the (- / +) C3 works lower resistance,
C 2 working fan, C1 works upper resistance + fan
motor for 60 Seconds. You will make a temperature
control: if the test finishes it is ok. To exit, turn the
machine
Technical Sheet DSDL_16019_A